P11 57 PAR EFIC

Equations
Problema 11.57
m
= 0, 25

(1)

PB = 100

(2)

PM = 600

(3)

PA = 1400

(4)

n=0.8
Refrigerante 134a
h11 = h (R134a; x = 1; P = PB )

(5)

s11 = s (R134a; x = 1; P = PB )

(6)

s21 = s11

(7)

h21i = h (R134a; s = s21 ; P = PM )

(8)

h21i h11
+ h11
n

(9)

h51 = h (R134a; x = 0; P = PA )

(10)

h61 = h51

(11)

h71 = h (R134a; x = 1; P = PM )

(12)

h81 = h (R134a; x = 0; P = PM )

(13)

h91 = h81

(14)

h21r =

y1 =

h61 h71
h81 h71

(15)

h31 = (1 y1) h71 + y1 h21r

(16)

s31 = s (R134a; h = h31 ; P = PM )

(17)

s41 = s31

(18)

h41i = h (R134a; s = s41 ; P = PA )

(19)

h41r =

h41i h31
+ h31
n

(20)

(a)
PorcRefEvap1 = (1 y1) 100

(21)

(b)
Q evap1 = y1 (m)
(h11 h91 )

(22)

(c)
ent1 = (y1 m
W
(h21r h11 )) + (m
(h41r h31 ))

(23)

ent1
COPR1 = Q evap1 /W

(24)

Refrigerante R12
h12 = h (R12; x = 1; P = PB )

(25)

s12 = s (R12; x = 1; P = PB )

(26)

s22 = s12

(27)

h22i = h (R12; s = s22 ; P = PM )

(28)

h22i h12
+ h12
n

(29)

h52 = h (R12; x = 0; P = PA )

(30)

h62 = h52

(31)

h72 = h (R12; x = 1; P = PM )

(32)

h82 = h (R12; x = 0; P = PM )

(33)

h92 = h82

(34)

h22r =

y2 =

h62 h72
h82 h72

(35)

h32 = (1 y2) h72 + y2 h22r

(36)

s32 = s (R12; h = h32 ; P = PM )

(37)

s42 = s32

(38)

h42i = h (R12; s = s42 ; P = PA )

(39)

h42i h32
+ h32
n

(40)

h42r =
(a)

PorcRefEvap2 = (1 y2) 100

(41)

(b)
Q evap2 = y2 (m)
(h12 h92 )

(42)

(c)
ent2 = (y2 m
W
(h22r h12 )) + (m
(h42r h32 ))

(43)

ent2
COPR2 = Q evap2 /W

(44)

Refrigerante R22
h13 = h (R22; x = 1; P = PB )

(45)

s13 = s (R22; x = 1; P = PB )

(46)

s23 = s13

(47)

h23i = h (R22; s = s23 ; P = PM )

(48)

h23i h13
+ h13
n

(49)

h53 = h (R22; x = 0; P = PA )

(50)

h63 = h53

(51)

h73 = h (R22; x = 1; P = PM )

(52)

h83 = h (R22; x = 0; P = PM )

(53)

h93 = h83

(54)

h23r =

y3 =

h63 h73
h83 h73

(55)

h33 = (1 y3) h73 + y3 h23r

(56)

s33 = s (R22; h = h33 ; P = PM )

(57)

s43 = s33

(58)

h43i = h (R22; s = s43 ; P = PA )

(59)

h43i h33
+ h33
n

(60)

h43r =
(a)

PorcRefEvap3 = (1 y3) 100

(61)

(b)
Q evap3 = y3 (m)
(h13 h93 )

(62)

(c)
ent3 = (y3 m
W
(h23r h13 )) + (m
(h43r h33 ))

(63)

ent3
COPR3 = Q evap3 /W

(64)

COP-Eficiencia Compresor

QL - Eficiencia

You might also like