Professional Documents
Culture Documents
Fundamentals
James Colotti
Outline
Introduction
- Importance of EMC
- Problems with non-compliance
Revision 3
EM Waves, Shielding
Layout and Partitioning
Power Distribution
Power Conversion
Signal Distribution
Design Process
References and Vendors
Copyright Telephonics 2003-2005
Introduction
Revision 3
Importance of EMC
Electromagnetic Compatibility (EMC) requires that
systems/equipment be able to tolerate a specified degree
of interference and not generate more than a specified
amount of interference
EMC is becoming more important because there are so
many more opportunities today for EMC issues
Increase use of electronic devices
- Automotive applications
- Personal computing/entertainment/communication
Revision 3
Revision 3
Significant
Property Loss
Critical communications
Interference/Interruption
Automated Monetary
Transactions
Death or
Serious Injury
RADAR, Landing
System Interruption
Erroneous Ordnance
Firing
Improper Deployment
of Airbags
Non-Compliance (continued)
Revision 3
Concepts
&
Definitions
Revision 3
Revision 3
Coupling Path
Conducted
Power Lines
Signal Lines
Revision 3
Radiated
Magnetic
Electric
Plane Wave
System/Device
that is
susceptible to
Interference
(Victim)
Coupling Path
Increase Separation
Shielding
Reduce # of Interconnections
Filter Interconnections
Receiver (Victim)
Modify Signal Routing
Add Local Filtering
Operating Freq Selection
Standards
Revision 3
US Military
Revision 3
10
FCC Part 15
Conducted Emissions
Frequency
(MHz)
Quasi-Peak Limit
(dBuV)
Average Limit
(dBuV)
Class A
0.15 0.5
0.5 - 30.0
79
73
66
60
Class B
0.15 0.5
0.5 5
5 - 30
66 to 56 *
56
60
56 to 46 *
46
50
Revision 3
11
FCC Part 15
General Radiated Emission
Revision 3
Frequency
(MHz)
Class A
(10 meters)
30 88
88 216
216 960
above 960
90
150
210
300
Class B
(3 meters)
30 88
88 216
216 960
above 960
100
150
200
500
12
MIL-STD-461E
Revision 3
Description
CE101
CE102
CE106
CS101
CS103
CS104
CS105
CS109
CS114
CS115
CS116
Conducted Susceptibility, Dampened Sinusoidal Transients, Cables & Power Leads, 10 kHz to 100 MHz
RE101
RE102
RE103
RS101
RS103
RS105
13
Description
EN50081-1
EN50081-2
EN55022
EN55011
Industrial, scientific and medical (ISM) radio frequency equipment Radio disturbance characteristics - Limits and methods of
measurement
(Also known as CISPR-11)
Revision 3
EN55013
EN55014-1
EN55015
EN61000-3-2
EN61000-3-3
14
Revision 3
Description
EN61000-4-2
Electrostatic Discharge
EN61000-4-3
EN61000-4-4
EN61000-4-5
Surge Test
EN61000-4-6
EN61000-4-8
EN61000-4-11
EN61000-6-1
EN61000-6-2
EN61547
EN12016
15
Revision 3
Title
Notes
16
Power Input
17
Voltage Spike
Power Leads
Up to 600 V or 2x Line Voltage
18
19
Interconnection Cabling
E field and H Field
400 Hz 15 kHz and spikes
20
21
22
16
Standard Summary
Revision 3
17
Design Guidelines
and
Methodology
Revision 3
18
Electromagnetic Waves
Revision 3
19
Electromagnetic Waves
ZW =
0
=
0
H
m = 120 = 377
1
F
10 9
36
m
4 10 7
d/
Revision 3
20
Shielding
Enclosure/Chassis
-
Mechanical Structure
Thermal Path
Can form an overall shield (important EMC component)
Can be used as first line of defense for Radiated
emission/susceptibility
Enclosure material
- Metal
- Plastic with conductive coating
(Conductive paint or vacuum deposition)
Revision 3
21
Shielding Illustration
Revision 3
22
Shielding Effectiveness
EInside
SEdB = 20 Log10
EOutside
- Reflective losses, R
- Absorption losses, A and
- Secondary reflective losses, B (ignore if A>8 dB)
SE = R + A + B SE = R + A
Revision 3
23
SE Equations
0.462
R h = 20Log10
r
0136
. r
+
+ 0.354
f r
r
f r
f 3r r 2
Re = 354 - 10 Log10
r
A = 0. 003338t rrf
Absorptive Loss
where:
t = Material thickness (mils)
r = Material permeability relative to air
r = Material conductivity relative to copper
f = Frequency (Hz)
r = Source to shield distance (inches)
Rp = 168 + 10 Log10 rf
r
24
SE Theoretical Examples
Freq
(Hz)
Copper (3 mils)
Magnetic
(dB)
Electric
(dB)
Plane
(dB)
Magnetic
(dB)
Electric
(dB)
Plane
(dB)
Magnetic
(dB)
Electric
(dB)
Plane
(dB)
10k
58
>200
141
125
>200
>200
45
>200
129
100k
101
>200
165
>200
>200
>200
57
186
121
1M
>200
>200
>200
>200
>200
>200
74
162
118
10M
>200
>200
>200
>200
>200
>200
106
154
130
100M
>200
>200
>200
>200
>200
>200
184
193
188
1G
>200
>200
>200
>200
>200
>200
>200
>200
>200
r=12
Revision 3
25
SE Practical Considerations
Revision 3
Removable Covers
Holes for control/display components
Holes for ventilation
Holes for connectors
26
Holes/Apertures d>t
Single Hole
If
If
<d
SE 0dB
>d
SE 20 Log10
Multiple Holes
If s <
> d and
SE 20Log10
2d
2d
s
<1
d
10 Log10 n
where:
t = Material thickness
n = Number of Holes
s = edge to edge hole spacing
Notes:
1. d is the longest dimension of the hole.
2. Maximum SE is that of a solid barrier without aperture.
Revision 3
27
c = 2w
f
2
1
=
c
fc
=
t
t
A = 8.686t = 27.3
w
Revision 3
Cutoff wavelength
Absorption loss
t/w
Loss
>200
164
109
55
28
Enclosure Seams
Revision 3
29
Gasketing Examples
Courtesy of Tecknit
Revision 3
30
Panel Components
Air
Ventilation
Panels
EMC Switch
Shield
Shielded
Windows
Courtesy of Tecknit
Revision 3
31
Galvanic Series
Revision 3
Galvanic Corrosion
32
Anodic
Index
(V)
0.00
Rhodium Plating
0.10
0.15
0.30
Beryllium Copper, Low Brasses or Bronzes, Silver Solder, Copper, Ni-Cr Alloys, Austenitic Corrosion-Resistant Steels, Most ChromeMoly Steels, Specialty High-Temp Stainless Steels
0.35
0.40
0.45
18% Cr-type Corrosion Resistant Steels, Common 300 Series Stainless Steels
0.50
Chromium or Tin Plating, 12% Cr type Corrosion Resistant Steels, Most 400 Series Stainless Steels
0.60
0.65
0.70
0.75
Wrought Gray or Malleable Iron, Plain Carbon and Low-Alloy Steels, Armco Iron, Cold-Rolled Steel
0.85
Wrought Aluminum Alloys (except 2000 series cast Al-Si alloys), 6000 Series Aluminum
0.90
0.95
1.20
1.25
1.75
Beryllium
1.85
Revision 3
33
Revision 3
34
System Partitioning/Guidelines
Culprit
Potential
Victim
Potential
Victim
Potential
Victim
Power Bus
Signals
Revision 3
35
Culprit
Potential
Victim
Potential
Victim
Potential
Victim
Power Bus
Signals
Culprit
Potential
Victim
Potential
Victim
Potential
Victim
Power Bus
Signals
Revision 3
36
Layout is 3 Dimensional
Revision 3
37
Inexpensive
Difficult to control EMI without
external shield
Difficult to control impedance
One Sided
Revision 3
Ground Plane
38
E-Field
Probe
Adding ground
plane reduces
emission of
fundamental 40 dB
No Ground Plane
Revision 3
39
Signal
Signal
Ground Plane
Ground Plane
Signal
Analog Signal/Power
Signal
Analog Signal/Power
Ground Plane
Signal
Ground Plane
Supply Plane
Signal
Signal
Ground Plane
Digital Signal
Signal
Supply Plane
Digital Signal
Ground Plane
Signal
Ground Plane
Signal
Signal
Signal
Revision 3
40
PWB Example
IF Processing
RF Sections
Video
ADCs
FPGA &
Support
Logic
High Speed
Digital I/O
Revision 3
41
Metalized Plastic
Shield Examples
Courtesy of Mueller
Revision 3
42
Revision 3
43
Linear
Switching
Revision 3
44
Controlled
Transition
Time PWM
Standard
PWM
Spread
Spectrum
PWM
Fixed
Frequency
PWM
Revision 3
45
Courtesy of Vicor
PWM
Topology
Resonant
Mode
Topology
Revision 3
46
System AC
Power
AC/DC
Power Converter
DC/DC
Converter
DC/DC
Converter
DC/DC
Converter
DC/DC
Converter
Load
Load
Load
Load
System AC
Power
System AC
Power
System AC
Power
Load
Load
AC/DC
Power Converter
AC/DC
Power Converter
AC/DC
Power Converter
Distributed DC
AC/DC
Power Converter
Load
Revision 3
Direct DC
Load
Load(s)
DC Power
(Multiple
Voltages)
Load(s)
DC Power
(Multiple
Voltages)
Load(s)
Separate Primary
DC Power
(Multiple
Voltages)
47
Personal Computer
(Direct DC Distribution)
Revision 3
48
Load
Ground
Loops
Load
Reg
Power
Effic
Load
Iso
Distributed
DC
Direct
DC
Separate
Primary
Revision 3
Notes
Legend:
+ Advantage
- Disadvantage
x Neutral
49
Signal Distribution
Revision 3
50
Cable Shields
Revision 3
51
Unassembled 360
Degree Backshell for D
Connector
Revision 3
Shield Example
95% Coverage Double Copper Shield
Shielding Effectiveness
Frequency
(Hz)
Revision 3
Xer Z
(/m)
Magnetic
(dB)
Electric
(dB)
Plane
Wave
(dB)
1k
100
100
10 k
16
100
100
0.0080
100 k
36
100
100
0.0080
1M
70
100
100
0.0014
10 M
90
90
90
0.0011
100 M
90
90
90
0.0060
1G
80
80
80
10 G
60
60
60
53
Vi
Is
( per meter)
Vi
IS
Transfer Impedance
Revision 3
54
Continuous shield
with both ends of
grounded directly
Revision 3
55
Continuous shield
with both ends of
grounded directly
Revision 3
56
Filter Connectors
57
Baseline
Revision 3
Discrete LC Filter at
Connector
(1nH, 8200p)
Filter Connector
(1nH, 8000 pF)
58
Selection Considerations
-
Spectrum of Signals
Source/Sink Capability of Driver
Source/Load Impedances
Cable effects
Frequency Domain
A(f)
20 dB/Decade
40 dB/Decade
Time Domain
f1
A(t)
f1 =
Time
Revision 3
Frequency (Hz)
tw
tr
f2
f2 =
tf
1
1
=
= 15.9MHz
tW (20ns )
2 1 2
1
= 159 MHz
=
t r + t f (2ns + 2ns )
59
Revision 3
60
Design Process
Process Example
Revision 3
61
Mechanical Design
Revision 3
System/Device
Specification
Generate
EMC/EMI
Control Plan
Electrical Design
Chassis/
Enclosure
Bonding
and
Grounding
Hardware
Partitioning and
Location
Shielding
Material Selection
Gasketing
Covers
System functional
allocation
Separation of analog,
RF, digital and power
System Design
PWB Layout
and
Construction
Power
Conversion and
Distribution
Micro-strip, stripline
Number of layers
Ground layers
Separation of analog,
RF, digital and power
Conversion Topology
Linear, Resonant,
PWM
Connector Selection
Filter/Non-Filter
Filter location/type
Signal
Distribution
Single Ended,
Differential
Logic Family
Connector Selection
Filter/Non-Filter
Filter location/type
Cable harnessing
and shielding
Signal Spectrum
62
Revision 3
63
References
Revision 3
64
References
Revision 3
65
Revision 3
66
www.Chomerics.com
www.LairdTech.com
www.Tecknit.com
www.Spira-EMI.com
www.WaveZero.com
www.LeaderTechInc.com
Revision 3
67
Backshell Vendors
www.SunBankCorp.com
www.TycoElectronics.com
Revision 3
68
www.GHtech.com
www.SpectrumControl.com
www.Amphenol-Aerospace.com
www.EMPconnectors.com
www.Sabritec.com
Revision 3
69