Atv Projects India Ltd. Mathura: Dye Penetrent Test Report
Atv Projects India Ltd. Mathura: Dye Penetrent Test Report
MATHURA
DYE PENETRENT TEST REPORT
Order No.
Component
name
Component
part
FLS-CSD/S/50636 VER-0
DT.11/04/14
Kiln shell ( 4.2 M)
Sec-1 (#1/6)
L.S- 1 Nos.
Report No.
ATV/QC/14/
Testing
Date(L.S-1)
Drawing No.
Material &
Grade
Area Examined
SA516 GR70
Welded V area
APPLICABLE CODE/SPECIFICATION
REFERENCE STANDARD:- EN571-1
ACCEPTANCE STANDARD:- EN ISO 23277 2X
Material used
MAKE
MODAL
Cleaner type
PMET
Penetrate type
PC5021
BATCH
NO.
16 8463
PMET
PP5011
04 7554
Developer
Type
PMET
PD5031
16 10069
Developing
time
Surface
condition
Final inspection
Observation
Result
Accepted.
APPROVED BY
DWELL time
Solvent removal
method
12 Minutes
12 Minutes
Free from dust &
Greece
After 10 Minutes
INSPECTED BY
(Signature of Inspection
Authority)
Report No.
ATV/QC/13/621 A
Testing Date
30/10/13 to 10/11/13
Order No.
FLS-CSD/S/45110 Ver
0,Dt.05/09/13
Drawing No.
Component
name
Component
part
Material &
Grade
Area
Examined
Stage
SA 516 Gr-70
Welded area
Plate to plate
backchip
APPLICABLE CODE/SPECIFICATION
REFERENCE STANDARD:- EN571-1
ACCEPTANCE STANDARD:- EN ISO 23277 2X
Material used
MAKE
MODAL
Cleaner type
CHEKM
ATE
CHEKM
ATE
CHEKM
ATE
CL -96
Penetrate type
Developer
Type
PT-97
DV-98
BATCH
NO.
CL-C-01245
CL-P-01229
CL-D-01247
Solvent removal
method
12 Minutes
12 Minutes
Free from dust &
Greece
After 10 Minutes
Result
Accepted.
APPROVED BY
(Signature of Inspection
Authority)
INSPECTED BY
Yogesh Sharma
M.L Ghamandi