You are on page 1of 3

ATV PROJECTS INDIA LTD.

MATHURA
DYE PENETRENT TEST REPORT

Ref. No.-ATV/QA/F/05 Rev-0


Customer
M/S FLSmidth Pvt Ltd.
name
Project name
Ultratech Vikram Cement

Order No.
Component
name
Component
part

FLS-CSD/S/50636 VER-0
DT.11/04/14
Kiln shell ( 4.2 M)
Sec-1 (#1/4)
L.S- 1 Nos.

Report No.

ATV/QC/14/

Testing
Date(L.S-1)
Drawing No.

20129994 Ver 1.0

Material &
Grade
Area Examined

SA516 GR70

Stage (L.S 1st)

After L.S. weld back


chip

Welded V area

APPLICABLE CODE/SPECIFICATION
REFERENCE STANDARD:- EN571-1
ACCEPTANCE STANDARD:- EN ISO 23277 2X

Material used

MAKE

MODAL

Cleaner type

PMET

Penetrate type

QAP NO.-QAP/SPARES/037/R(0) DT.


26.03.2014
TEST DETAIL
Test method

PC5021

BATCH
NO.
16 8463

PMET

PP5011

04 7554

Developer
Type

PMET

PD5031

16 10069

Developing
time
Surface
condition
Final inspection

Observation

No defective indications were observed.

Result

Accepted.
APPROVED BY

DWELL time

Solvent removal
method
12 Minutes
12 Minutes
Free from dust &
Greece
After 10 Minutes

INSPECTED BY

ATV PROJECTS INDIA LTD.


MATHURA
Yogesh Sharma
M.L Ghamandi
(Q.C Engr.)
(Q.C Head)

(Signature of Inspection
Authority)

DYE PENETRENT TEST REPORT

Ref. No.-ATV/QA/F/05 Rev-0


Customer
M/S FLSmidth Pvt Ltd.
name
Project name
BINANI CEMENT

Report No.

ATV/QC/13/621 A

Testing Date

30/10/13 to 10/11/13

Order No.

FLS-CSD/S/45110 Ver
0,Dt.05/09/13

Drawing No.

20123416 Ver 2.0

Component
name
Component
part

Kiln shell 4.55 M)

Material &
Grade
Area
Examined
Stage

SA 516 Gr-70

Sec-1 (#1/1,#1/2, #1/4)


L.S- 1

Welded area

Plate to plate
backchip
APPLICABLE CODE/SPECIFICATION
REFERENCE STANDARD:- EN571-1
ACCEPTANCE STANDARD:- EN ISO 23277 2X

Material used

MAKE

MODAL

Cleaner type

CHEKM
ATE
CHEKM
ATE
CHEKM
ATE

CL -96

Penetrate type
Developer
Type

PT-97
DV-98

BATCH
NO.
CL-C-01245
CL-P-01229
CL-D-01247

QAP NO.- QAP/SPARES/115/R(0)


DT.17/09/13
TEST DETAIL
Test method
DWELL time
Developing
time
Surface
condition
Final inspection

Solvent removal
method
12 Minutes
12 Minutes
Free from dust &
Greece
After 10 Minutes

ATV PROJECTS INDIA LTD.


MATHURA
Observation

No defective indications were observed.

Result

Accepted.
APPROVED BY

(Signature of Inspection
Authority)

INSPECTED BY

Yogesh Sharma
M.L Ghamandi
(Q.C Engr.)
(Q.C Head)

You might also like