You are on page 1of 10
MAGNETIC LEVEL GAUGES eee Magnetic Level Gauge employ two elementary principles. 1) Archimedes Principle accordinato which a body Immersed in aliquid receives a buoyancy equal to the weight ‘of displaced liquid. i) Principle of attraction among dissimilar poles of permanent magnets and that of repulsion between like poles. ‘Afloat containing magnet follows liquid level in the liquid chamber which corresponds to the level in the tank. Position ofthe float inside the chamber is indicated outside by bicoloured flappers embedded with magnet by 1180°rotation and setting into uniform colour along the traverse of the float. Flapper Color Indication la z White Vapour NST Nile m Practically for all liquids: inflammable, explosive, poisonous ... etc. m Specially for those which attack glass. 1m For Inter-phase. & Upto 2500 psi and upto 300°C. 'm Specific gravities 0.34 and above. mrooucrow MAGNETIC FLOAT TYPE LUCE eae ae Tes DA ed) he magnetic flat gauge is designed so that the fuid being measured is enclosed within, a sealed chamber. A float fited with a permanent magnet moves freely i ‘the chamber and activates the flappers of the aluminum indicator mounted on the outside ofthe chamber. [As the magnetic fioat passes each fapper with fising or faling with Tquid level, The flapper rotates 180° to show the other color. tating fappers are instaled in the Non- Magnetic Case a intervals of 10 mm or so. It doesn't fail to indicate even at the sudden change of liquid level. The liquid phases and gaseous are indicated by red color and white ‘olor respectively. ® agnetic Type Level Indicators an instrument for indicating the fuid level. It has a magnetic lat inside of the Non-Magnetic Chamber and an indicator outside of it The indicator indicates ‘uid level by means of magnetic force of the magnet instal inside the fat. The Indicator is completely separated from the chamber. ‘The level of iquid and gaseous phases ‘can be distinguished cleaty by the Bi- Color. 5 3 a ie Seater eee Sy BS ies) sy) STANDARD TYPE Sas MAGNETIC FLOAT TYPE ‘SPECIFICATIONS 1 Column Sizo = DNBS. 1 Schedule ‘SCH 40S, 808, otc. 1m Flange Rating ‘9001.8 ~ 250018, 1 Naterial 30488, 3168S, 316L8S Titanium, Monel, etc. 1 Max. Working Pres, 2500 PSI. 1 Max. Working Temp. 400 deg C. @ Specific Gravity Min, 0.622. SMF-65Ais Used for more higher pressure up to 25000 than ‘SMF-50A of standard type. Sinclar | “Cava. an ober are aso aelsde an request,“ Gob ave Nipple & Cap| eae) @ Column Size NSO. @ Schedule + SCH 10S, 205, 40S, etc. & Flange Rating + 150LB ~ 900LB, ‘PVC : 150LB ONLY. i Material ‘3048S, 31685, 316LSS Titanium, PVC, Mone, ete. 1 Max. Working Pres. Psi. 1 Max. Working Temp, 400 deg C. 1 Specc Gravity =: Min. 0.34. ‘SMF-50A is Used for observing almost al fd which is poisonous gas oF liquid tank and boiler drum wih low & middle pressure up to 900Ib and its have weight with ‘outstanding safely from ils damage or breakage and to be of low price. “Others, except the above specication are avatable on request by customer. Biel EY Net leg a sy + DNSQ. + SCH 10S, 208, 405, etc. + 450LB ~ 900LB, ‘30485, 3165S, 316LSS Titanium, Monel, etc, +900 PSI. 2-200 +150deg C. + Min, 0:34, ‘SMF-50AN for low temperature is. ‘Used for protecting the frost at extremely low temperature applications, thereby you can obviously visible the flapper color to indicate it fluid level, ‘Max. Working Pres. 600 PSI. | Max. Working Temp. 400 deg C. 1m Specific Gravity + Min, 034, ‘SMF-50AJ for Heating and Cooling is Used for observing the level of highly congealable or ebulient liquids. The principle isin fw a steam for liquids end a cold water for ebulient liquids through the inside of the jacket ppe. i Se Pe a quchesmecs oa ornut| ~ Cob Sie a (ETN 3dAL LVOTd OULANOWW “Others, except the above specification are available on request by customer. eT Ue aS at SSS al Ve ae + DNSO, SCH 5S, 105, ec. + 150LB ~ 30018, ‘30485, 3168S, 316185, 1 Max. Working Pres. :300 PSL, 1 Max. Working Temp. :400 deg C. ‘SMF-SOALD for Corrosive Fluid is Used for observing the corrosive fluid effectively by {ining all the wetted part of this type. E g eae Oy FOR UNDERGROUND TANKS 2 ‘SMF-50AU Ez ‘@ Column Size ‘Schedule 1 SCH 108, 208, etc. g 1 Flange Rating + IBOLB ~ 300LB, 1 Material 3048S, 3168S, 316LSS = Titanium, Monel, etc. | = & Specific Gravity Min. 0:34. ‘SMF-S0AU is Used for observing the fluid in underground tanks or tanks under manhole, fw Sea Pe a Unit : cent-meter{Cm] as standard ~~ Plug: ‘and ors ae abo avetaieanrquest| _~ Nple & Cap. “Others, except the above specification are available on request by customer. ASSEMBLY MAGNETIC FLOAT GAUGE This Assembly is suitable for alarm and control of various liquid, any fuid can be observed by through its central control system. MODEL: SCF-1 MODEL : SEMS-90 MODEL : SEMS-90 Ee ‘Alarm swiich has the seltholding type leed switch. Thats, when the N pole of magnet float coming near, ‘he swich wil be closed [ON], afer the magnetic fot passed by, the switch sil remain closed [ON]. and when the magnet is coming back, the switch will be opened [OFF] again. and after the magnet passed ‘way, the switch sil remain open [OFF] aso. When the switch is installed in the opposite ditecton, the ON-OFF operation ofthe former wil be reversed Therefore, the operation [ON-OFF] is easy to change onthe side. ‘As our switch has no polarization, There is ite point in arguing about an electric circuit whether wires are connected with terminal 1 or2. see ely ‘SEMS-90 ‘SOFA MODEL Si Max. DC-A 05/0254 —[4~20mA Max. AC-V. 410 /220V_ mV ‘Temp. Range | _-10~ 80°C. 0°C Conduit PF 2 PF AZ Remark. Ba 0B +H Té | Bed 1B Ts IPOS SEMS-90 is ‘The Level Switch is installed on a certain place of column or magnet chamber. It operates ON-OFF contol by means of magnetic force ofthe foat when it ‘comes up or down the exact place of switch located. LEVEL TRANSMITTER Used for detecting the level of measuring object fom various level in the vessels or tanks and for ‘ransmiting it ater converting to electic output signal ‘and direct indication can also be possible with flapper colors. ‘A transient changing of liquid level is continuously ‘ranamited by converting change of resistance value level switch insted on the chamber. ‘Others, except the above specification are available on request by customer. (SMES HS 3dAL LVO1d OUSNOVIN Ue Sea er Tee easy ume MAGNETIC FLOAT TYPE ea . Visible Length 100 Coc Flat] + 10 Float Lengths are totally difference depend on the specific gravity of liquid. a cc Flt + 10 OFFICE Plat No R-S87H, NIDG, Rabale TTC industal Area, Thane Belapur Road, ‘NAVI MUMBAI 400 701 Pa: 0222760184516 FAX :02227899063, REGIONAL OFFICES DELHI 4008, 4h Floor, Bhikoj Kama Bheven Bij Kama Place New Dehi-t10 06 Pr.Nos: Ov-ZeTU8NZH, 2190320 Faxlo. 044-26408043 CTP: Mr. Mano} Gera-d9at3324004 ir Mesh Gunto-0935065444 Emel; mgaragichentrolssanilcom, eedel@snine BARODA 401, Glacier, \Jotalpur Rad, Vadodara 390 007, Ph. tos: 0265-2947328 Faxllo —0285:797508% CTP: ‘Mr. Sunil Lakhanpalezze4g¢601 Mir, Purvsh Sheh-00427352966 Emil: purish@chemivolssamilcom CHENNAI No. 72, “Sri Arunaohala’ 4th Avenue, Ashok Nagar ‘Shenna-6o0 083, Philos: 0444s051191/979304 Fax Wo: O44z054194 CTP: M.S. Ravichandran-09982822353, Emel: ravi@shemolscoin PUNE 4513, Voishall Society Behind Meera Society, Sharkar Sheth Road, Puncattt 007 PhNos: 020-27612851 Fax 020-66114784 CTP: Br. Adwait Joshi 0485500604 Email: celbune@vshoo.com AMIL() PVT.LTD. FACTORY. Plot No R24, MIDE, Rebale TTC Industral Aree, Thane Belapur Road, NAVI MUMBAI 400 701 PH: 022-27606519 FAX: (2227607324 HYDERABAD Flat No, 902, Ganga Plaza, 169, Vasaveinagar Kherkhana Securderabad-S00 016 Ph.Nos.: U4U-2/(4324, 21743821 Fax No: —040:27743619 CTP: ‘Mr. Daniel P..-09885002344 Mr. EdigaR. Prasad-09833735024 Email: chemthydisatyamnetin KOLKATA 4A, Shekespeare Sarani New B.K, Market, Sth Floor Kalkaeo0071 hls: aRzazandany, 7834967 Fax No: 03222834844 CTP: ‘Mr. Raju Mathew-09339752395 Erma: goelln@vornet BANGLORE Golden Square, 102, Eden Park, 20 vittl Mallya Roed Banglore-369 001 PhNos: 08022243860 FaxNo: 080-22994605 CTP; Mr, Ravindra Vijaya-09042492359 E-mail; ravindravjaya@omail.com ICHEMTROLS SAMIL(I) PVT.LTD OFFICE PootNoR-S87t, NID, Rabae ‘TTC Industral Area, Thane EolapurRoad, (NAVI MUMBA 400 704 PH: 07227694845/46 FAX : (22 27839063 Enail: chensam@ctemirolssamil com REGIONAL OFFICES DELHI 1006, 10th Floor, Bhikaji Kama Bhavan Bhilai Kora Pace New Dalit 1006 Pr.los: O4t-2604wes, 2495830 FaxNe: 041-26408943 CTP Mr Manoj Garguns‘33uoet Mr, Mukesh Gupa-O8980551411 BARODA 401, Glcler, stalpur Reed, Vadodara 30 O17, Pr.Nos: 0265-22328 FaxNex: (266-2228089, CTP, Mr Sunil LaxhorpalowaBésesos fir, Purvish Shat-09427252966 CHENNAI Wu, 72,81 Auuactide’, 4th Avenue, Ashok Nagar henna-600 (63 Pr.Nos: O4420541640203/04 FaxNe: — 0ddst3054404 CTP: M.S. Ratichancran-o9ig7377353 PUNE 453, Valshal Society Behind Meera Society, Shankar Shah Road, Punaettt 097 Pros: 020-27617864 Faro: 07056144764 CTP: Mr, Adwat Joshi-08823500604 FACTORY Plot tho R-24, MIDC, Rebele TTC ndustial Aree, Thane Belapur Road, NAVI MUMBAL 400 7C4 PH: (22 27606519 FAY: 122 27607324 Email: chentrolssami@gail.cxm HYDERABAD Fe No. 30, Ganga Phiza 468, Vasavamnaga Kherkhana Secunderebad$00 016 PhNos; 4027743520 27743824 FaxNo: 04027743519 CTP: Mr Daniel Px. o9seso02344 Mr. sigaR, Prasad 9833235924 KOLKATIA ‘168, Shakespeare Sant New B.K. Market, 5h Foor Koksta700074 Pa.Nos: 03-22804H02, 2834062 FaxNos 03-2891 CTP: Mr, Raju Nathew 09239752105 BANGLORE Golden Square, 102, Bien Pak, 20 vital Maya Roed Bang ore-6) 004 Ph.Nos: 080-22243360 Fay No: 08020994505 CTP: Mr Ravindra Vijayesn347407358

You might also like