Combustion calculations per kg of fuel by G.Subhash Reddy
Fuel Rice Husk Gross Calorific Value (GCV) 2000 C 40 H 8 S 0.19 O 40 N 0.49 M 9.32 ash 2 Total 100 Unburnt Carbon-%of fuel 1 Ambient Temperature 40 Excess air 1.4 Boiler exit temperature 160 Radiation, ash and other losses 2.5 Altitude - m 100 Humidity.fraction 0.6 Moisture fraction in air 0.028795 Theoretical Oxygen required 1.2784 Theoretical air required 5.522246 Actual air required 7.96036 Flue gas produced 8.93036 Air moisture 0.229215 Combustion moisture 0.7152 Fuel moisture 0.0932 Total moisture 1.037615 CO2 1.4313 SO2 0.0038 N2 5.946285 O2 0.51136 Total gas - check 8.93036 O2 % by weight 5.726085 CO2 % by weight 16.02735 H2O % by weight 11.61896 Dry gas loss % 11.36555 Loss due to moisture in air % 0.687646 Loss due to hydrogen moisture % 22.8864 Loss due to moisture in flue gas % 2.9824 Loss due to unburnt carbon % 3.9 Total loss % 44.322 Air density at 0 C temp 1.282387 Flue gas density at 0 C temp 1.237536 CO2 % by volume 0.101156 Moisture % by Volume 0.178845