You are on page 1of 211

MAHARASHTRA JEEVAN PRADHIKARAN

( Government of Maharashtra Undertaking )

SCHEDULE OF RATES
FOR THE YEAR - 2012-2013

NASHIK REGION
( Effective from

24-12-2012 )

APPLICABLE FOR NASHIK REGION


MAHARASHTRA JEEVAN PRADHIKARAN WORKS

Countersigned For The Year 2012-2013

CHIEF ENGINEER (URBAN & RURAL)


Maharashtra Jeevan Pradhikaran
Thane

MAHARASHTRA JEEVAN PRADHIKARAN


Nashik Region
SCHEDULE OF RATES
FOR THE YEAR - 2012 - 2013
INDEX
Section
No

Name of Section
Government Resolutions
General Notes

Materials

Labour and Machinery

Transportation

Standard weight and Cement Consumption

Excavation

Iron & Structural Steel Work

Plain & Reinforced Cement Concrete

Misellaneous Works

Pipes
I

C.I./D.I.Pipes

II

A.C. Pipes

III

P.V.C.Pipes

IV

G.I.Pipes

Stoneware Pipes

VI

R.C.C.Pipes

VII

P.S.C.Pipes

VIII

B.W.S.C. (Bar Wrapped steel Cylinder) Pipes

IX

G.R.P.Pipes

H.D.P.E.Pipes / M.D.P.E Pipes

XI

P.C.C.P.Pipes

XII

Pipe Appurtenances

XIII

Mechanical Joints/Fittings

XIV

M.S.Pipes

XV

Fabrication of M.S.Pipes and Specials

XVI

M.S.Pipes Laying

XVII

Treatment Plants ( WTP - STP )

XVIII R.C.C. G.S.Rs and Sumps

XIX

R.C.C. E.S.Rs

XX

Chambers, Manholes and Drainage Drops

XXI

Well Sinking and River Infiltration Works


Ancillary items for Reservoirs

Trial Run

Drawings

Page Nos.
From
To

GOVERNMENT RESOLUTIONS

, .
1090/-163/39-, . 7 1990

- 1

1
1

2
1.
2.
3.
4.
5.
6.

2.


50

3


-- " --- " --- " --- " --

7.

-- " --

8.
9.
10.
11.
12.
13.
14.
15.
16.

----------

"
"
"
"
"
"
"
"
"

----------

4
(1)

20


50

(1)

(2)
(3)
(4)
(5)

(6)
(7)
(8)
(9)
(10)
(11)
(12)
(13)
(14)

(2)

2
17.
18.

3
-- " --- " --

4
(15)

3.

19.
20.
21.
22.
23.
24.

-------

"
"
"
"
"
"

-------

(16)
(17)
(18)
(19)
(20)
(4)

4.

25.
26.
27.
28.
29.
30.

-------

"
"
"
"
"
"

-------

31.
32.
33.
34.
35.
36.
37.
()

--------

"
"
"
"
"
"
"

--------

(27)
(28)
(29)
(30)
(31)
(32)
(32)

38.
39.
40.
41.

-- " --- " --

5.

6.
7.

(3)

(21)
(22)
(23)
(24)
(25)
(5)

(33)
(34)
(35)
(36)

42.
43.
()

-- " --- " --

(37)
(38)

44.
45.
46.

-- " --- " --- " --

(39)
(40)
(41)

8.

2
47.
48.
49.
50.
51.
52.
53.
54.
55.
56.
57.
58.

3
-- "
-- "
-- "
-- "
-- "
-- "
-- "
-- "
-- "
-- "
-- "
-- "

-------------

4
5
6
(42)
(43)
(44)
(45)
(46)
(47)
(48)
(49)
(50)
(51)
(52)

(6)

(7)
,

,

,

9.
10.

11.

60.

-- " --

61.
62.
63.
64.
65.
66.
67.
68.
69.
70.
71.
72.
73.

--------------

"
"
"
"
"
"
"
"
"
"
"
"
"

--------------


(53)
(54)
(55)
(56)
(57)
(58)
(59)
(60)
(61)
(62)
(63)
(64)
(65)

(8)

2
74.
75.
76.
77.

3

-- " --- " --- " --

4
(66)
(67)
(68)

(9)
-

78.

-- " --

(10)

79.

-- " --

(11)

80.

-- " --

(12)

-- " --

81.

-- " --

(13)

-- " --

82.

-- " --

(14)

83.
84.
85.

-- " --- " -

86.

-- " --

15.
16.

87.
88.

-- " -

17.

89.

-- " --

-- " --

(19)

-- " --

(20)

(72)

12.

13.
14.

18. 90.
91.

92.

(69)
(70)

(15)

(16)
(71)
(17)

(18)

2
93.

3
-- " --

4
-

5
(21)

19.

94.

-- " --

(22)

95.

-- " --

(23)

, .
1090/-163/39-, . 7 1990

- 2



1)

1) 2) 3) 4) 5) 6) 7) 8)
1) 9) 10) 11) 12) 13) 14)
15) 16) 17) 18) 19) 20) 21)
22) 23) 24) 25) 26) 27) 28) 29)
30) 31) 32) 33) 34) 35) 36) 37)

2)

1) 2) 3) 4) 5) 6)
7) 8) 9) 10) 11) 12) 13)
14) 15) 16) 17) 18) 19)
20) 21) 29) 30) 31) 32)
33) 35) 36) 37) 38) 39)
40)

3)

1) 2) 3) 4) 5) 6) 7) 8)
9) 10) 11) 12) 13) 14) 15)
16) 17) 18) 19) 20) 21) 22)
23) 24) 25) 26) 27) 28) 29)

4)

1) 2) 3) 4) 5) 6) 7) 8)
9) 10) 11) 12) 13) 14) 15) 16)
17) 18) 19) 20) 21) 22) 23)
24) 25) 26) 27) 28) 29) 30)
31) 32) 33) 34) 35) 36) 37) 38)
39) 40) 41) 42) 43)

Page 1

5)

1) 2) 3) 4) 5) 6) 7) 8)
9) 10) 11) 12) 13) 14) 15)
16) 17) 18) 19) 20) 21)
22) 23) 24) 25) 26) 27) 28)

6)

1) 2) 3) 4) 5) 6) 7) 8)
9) 10) 11) 12) 13) 14) 15)
16) 8) 19) 20) 21) 22) 23)
24) 25) 26) 27) 28) 29)
30) 31) 32) 33) 34) 35)
36) 37) 38) 39) 40)
41) 42) 43) 44) 45) 46) 47)
48) 49) 50) 51) 52) 53) 54)
55) 56) 66) 67) 68) 69) 70)
71) 72) 73) 74) 75) 76)
77) 78) 79) 80) 81) 82)

7)

1) 2) 3) 4) 5) 6) 7) 8)
9) 10) 11) 12) 13) 14)
15) 16) 17) 18) 19) 20)
21) .

8)

1) 2) 3) 4) 5) 6) 7)
8) 9) 10) 11) 12) 13) 14)
15) 16) 17) 18) 19) 20)
21) 22) 23) 24)

9)

1) 2) 3) 4) 5) 6) 7)
8) 9) 10) 11) 12) 13) 14)
15) 16) 17) 18) 19) 20)
21) 22) 23) 24) 25) 26) 27)

10)

1) 2) 3) 4) 5) 6) 7)
8) 9) 10) 11) 12) 13) 14)
15) 16) 17)

Page 2

11)

1) 2) 3) 4) 5) 6) 7) 8)
9) 10) 11) 12) 13) 14)
15) 16) 17) 18)

12)

1) 2) 3) 4) 5) 6) 7)
8) 9)

13)

1) 2) 3) 4) 5) 6) 7)
8) 9) 10) 11) 12) 13) 14)

14)

1) 2) 3) 4) 5) 6) 7) 8)
9) 10) 11) 12)

15)

1) 2) 3) 4) 5) 6) 7)
8) 9) 10) 11) 12) 13) 14) 15)
16) 17) 16) 17) 18) 19) 20)
21) 22)

16)

1) 2) 3) 4) 5) 6) 7)
8) 9) 10) 11) 12) 13)
14) 15) 16) 17) 18) 19) 20)
21) 22) 23) 24) 25) 26) 27)
28) 29)

17)

1) 2) 3) 4) 5) 6) 7) 8)
9) 10) 11) 12) 13) 14)
15) 16) 17) 18) 19) 20)
21) 22) 23) 24) 25) 26)
27) 28) 29) 30)

18)

1) 2) 3) 4) 5) 6) 7) 8) 9)
10) 11) 12) 13) 14) 15) 16)
17) 18) 19) 20) 21) 22) 23)
24) 25) 26) 27) 28) 29) 30)
31) 32) 33) 34) 35) 36) 37) 38)
39) 40) 41) 42) 43) 44)
45) . 46) 47) 48)

Page 3

19)

1) 2) 3) 4) 5) 6) 7) . 8)
9) 10) 11) 12) 13) 14) 15)
16) 17) 18) 19) 20) 21)
22) 23) 24) 25) 26) 27) 28)
29)

20)

1) 2) 3) 4) 5) 6) 7) 8) 9)
10) 11) 12) 13) 14) 15)
16) 17) 18) 19) 20) 21)
22) 23) 24) 25) 26) 27) 28)
29) 30) 31) 32) 33) 34) 35)
36) 37) 38) 39) 40) 41) 42)
43) 44) 45) . 46) 47) 48)
49) 50) 51) 52) 53) 54)
55) 56) 57) 58) 59) 60) 61)
62) 63) 64) 65) 66)

21)

1) 2) 3) 4) 5) 6) 7) 8)
9) 10) 11) 12) 13) 14) 15)
16) 17) 18) 19) 20) 21)
22) 23) 24) 25) 26) 27)
28) . 29) 30) 31) 32) 33) 34)
35) 36) 37) 38) 39) . 40)
41) 42) 43) 44) 45) 46) 47)
48) 49) 50) 51) 52) 53) 54)
55) 56)

22)

1) 2) 3) . 4) 5) 6) 7) 8)
9) 10) . 11) 12) 13) 14)
15) 16) 17) 18) 19) 20)
21) 22) 23) 24) 25) 26)
27) 28) 29) 30) 31) 32)

Page 4

23)


1) 2) 3) 4) 5) 6) 7)
8) 9) 10) 11) 12) 13) 14)
15) 16) 17) 18) 19) 20) 21)
22) 23) 24) 25) 26) 27) 28)
29) 30) 31) 32) 33) 34) 35)
36) 37) 38) 39) 40)

Page 5

MAHARASHTRA JEEVAN PRADHIKARAN


NASHIK REGION
SCHEDULE OF RATES FOR THE YEAR 2012-2013
GENERAL NOTES
1 These rates are applicable to all MJP works in the NASHIK REGION with effect from

dated 24.12.2012
2 Item of excavation is inclusive of normal manual dewatering, however, seperate item for

dewatering shall be proposed in the estimate where underground water is anticipated in


significant magnitude.
3 The rates of excavation for O & M works where limited working space is available and

work is required to be carried out on emergency basis, the rate should be adopted as per
the actual rate analysis which shall be approved by concerned S.E. for that particular
work only.

4 Rates for all items are inclusive of all taxess levied by Central Government, State

Government or Local Bodies.Labour rates are inclusive of EPF 12.5 % . These rates are
applicable only for tendered works,these rates should be reduced by 12.50 % of labour part when
works are to be carried out on piecemeal works and other small works without tendering.

5 As per Government Notification No. 25/2012/service tax dated 20 June 2012 point no. 12 E

Service tax exempted for pipeline, conduit or plant for i) Water supply ii) Water treatment or iii)
Sewerage treatment or disposal
6 For all completed items, initial lead of 5 kms. is considered for collection of materials like

sand, bricks, metal, stone etc. Appropriate addition for lead charges excluding loading ,
unloading for these materials shall be done while estimation.
7 These rates are applicable to water supply and sewerage schemes and its allied works

only. Rates for Items required for general construction, buildings, roads, Irrigation Works etc.
shall be adopted from the current schedule of rates of P.W.D. or Irrigation Deptt. in
respective areas. For bore wells, CSR. of GSDA shall be followed. Increase in percentage
over normal schedule of rates will also be as per norms of respective C.S.R.
8 For mechanical and electrical items related to water supply and sewerage schemes, CSR

for 2012-2013 prepared by Superintending Engineer (Mechanical ), Maharashtra Jeevan


Pradhikaran shall be adopted.
9 Following increase in % over normal schedule of rates of M.J.P. for 2012-2013 will be
applicable. (Ref. PWD GR. No. DSR/1091/CR-6577/Planning-3,dated 08/07/2003)
Area
a
b
c
d
e
f
g

Works in Corporation area


Works in Municipal areas
Works in tribal area / hilly and inaccesible areas
Suger cane area
Prison / Jail area
Defence area
Excavation for pipeline work along National Highway

% Increase
5%
2%
10%
5%
15%
20%
10%

h Excavation for Dist.system pipe lines,Sewerage system in


towns

10%

10 In case more than one percentage increase on basic rates becomes admissible, instead

of adding both, the higher percentage only be taken. (e.g. if any Municipal Council falls in
hilly area, then additional percentage in rates will be only 10 % and not with 2 % + 10 %).
This additional percentage is only on completed item of work and not applicable to items
of providing of materials like steel, pipes, valves, specials etc

11 For hilly and inaccessible areas / Tribal areas approved by Government, Planning

Department's Circular Nos.(1)1089/CR-66/Plan-19,DT.23/11/1990 and (2) 1094/P-36/K-1455


dt.02/09/1994, shall be followed (refer pages 347 onwords). In addition to amendment
notification by the planning deptt. time to time.
12 For Action Plan Notified Area, Government's Circular in force from time to time shall be

followed.
13 Whenever basic rates of completed items are increased by percentage given at Sr. No. 9,

the issue rates of materials to be supplied by the Department ( if any) shall be increased
by same percentage.
14 This schedule of rates is based on following basic rates for important materials.

a
b
c
d
e
f

Material
Cement
Mild Steel
Tor Steel/CTD bars
Structural Steel
Corrosion Resistant Steel (Fe 500)
M.S.Plate

Rate in Rs. Per MT.


6200
48000
48300
48875
48875
49000

15 Details of standard cement consumption and standard weight of various pipes are

incorporated in this CSR .


16 Rates for supply of various types of pipes, specials and valves are inclusive of excise

duty, central sales tax and VAT, third party inspection charges, storage charges, overhead
charges and transportation of materials upto divisional stores and stacking.
17 Cost of carting of pipes and valves from departmental stores to site of work is not

considered in rate analysis, hence this item must be incorporated in each scheme. While
inviting tenders if supply is from departmental store, then this item shall appear in the
tender, and if the supply is by contractor then this item shall not appear in the tender,
even though same is provided in sanctioned scheme, because the contractor is supposed
to bring the pipes and valves directly at site.
18 Though the contractor is required to do refilling before hydraulic testing to avoid traffic

hurdle, no payment for refilling of the trenches of pipeline shall be payable till satisfactory
hydraulic testing is given. Re-excavation required if any, during testing, shall be done by
the contractor at his own cost.
19 10 % of cost of items of water retaining structures, such as GSR/ESR/MBR shall be

retained till satisfactory hydraulic testing is given as per IS code.


20 10 % of cost of total sub-work of pipeline work shall be retained, till satisfactory hydraulic

test is given, as per IS code.

21 In case of supply of pipes / valves etc. by contractor, only 85% payment shall be released

after supply and 15% after satisfactory hydraulic testing.


22 AC / PVC/HDPE pipes shall not

be used in Urban Areas.

23 Provision for octroi charges for pipes specials and valves is not considered in the CSR 2012-

2013. Provision of 4 % of cost for pipes specials and valves to be used in corporation area
shall be made while framing the estimate for works included in corporation limit. Octroi
charges shall be reimbursed to contractor on production of receipt for payment for
materials actully to be used in corporation area, if there specific provision to that effect in
the contract.
24 For use of ready mix cement concrete, prior permission of the Chief Engineer must be

obtained.
25 For Dams , Balancing Tanks , Aerated Lagoons and similar structures, the rates for Film

membranes as per prevailing rates for Irrigation Department will be followed.


26 Capacity of ESR / GSR to be constructed shall be rounded to nearest 1000 litres always

on higher side i.e. if required capacity is 1,23,570 litre, it shall be rounded to 1,24,000
litre. Similarly, if required capacity is 8,26,070 litre, it shall be rounded to 8,27,000 litre.

27 Capacity of Unconventional / conventional Treatment Plants shall be rounded to nearest 0.5

Mld- always on higher side i.e. if WTP of 2.37 Mld is required; it shall be rounded to 2.5
Mld. For WTP having capacity less than 0.5 mld, package type WTP should be
considered.
28 Provision for insurance at 1% is considered in Rate analysis of CSR 2012-2013. These rates are

applicable only for tendered works,these rates should be reduced by 1 % of total rate when works
are to be carried out on piecemeal works and other small works without tendering.

29 Rates given in this CSR are for estimation purpose only.


30 The makes of Sluice / Butterfly valves etc. to be used for inlet / outlets of ESRs / GSRs / MBRs /

Pumping main / Rising main and WTP should be from approved makes of M.J.P .
31 Mechanical CSR rates for respective items shall be followed while estimation and the list of

approved makes shall be given in the item.


32 As per Govt.Circular, Materials used for drinking water supply scheme upto first storage point and

pipes of more than 100 mm Dia are exampted from excise duty. However, necessary certificate
from project authority I.e. Distrct Collector / Dy. Commissioner shall be obtained.Also examption
from excise duty is applicable for following conditions.
1) All items of machienery, including instruments, apparatus & applicances, auxillary equipments
& their
components/parts required for setting of water treatment plant;
2) Pipes needed for delivery of water from its source to the plant (including the clear treated water
reservoir, if any, thereof) and from there to the first storage point;
3) Pipes of outer diameter exceeding 100 mm, when such pipes are integral part of the wtaer
supply project;
However, necessary certificate from Project Authority i.e. District Collector /Dy.Commissioner
shall be obtained.

33 The royalty charges are considered in the rate analysis of CSR 2012-13 As per Government

Resolution No. Rev and forest Dept Gaukhani 10/1009/ Pra.Kra.309/Kha. Mantralaya
dt.11.2.2010.
34 As per Govt.Circular No.DSR-1090/CR-6453/PLN-3, Dated 14.7.1993 1% for labour amenities is

not considered in the DSR except concrete item while arriving the rates.
35 As per Govt. in Industries & Power G.R. No.BCA-2009/CR-108/Labour 7-A, Dated 17.6.10, 1%

cess on labour welfare is not considered in the DSR while arriving the rates.

SECTION - A : MATERIALS
Sr.No.

Description

Unit

Rate ( in Rs.)
2012-2013

Acetylene Gas

Alum grade I (ex. Factory)

Cylinder
MT.

8000.00

Binding wire

Kg

60.00

Black enamel paint (anti-corrossive)

Ltr.

187.00

Bricks (Delivery at site of work)

No

5.50

Bullies,Struts (125mm dia 1.5 m long)

RMT.

187.00

C.C.T.W. planks (3"X6")

Cum.

72000.00

Cement in bags

Bag

310.00

Cement

M.T.

6200.00

10

Cement Sulpher resistant

M.T.

6600.00

11

Charcol

Kg.

12

Coarse sand

13

Corrosion Resistant Steel

MT

48875.00

14

Diesel

Ltr.

52.35

15

Epoxy paint

Kg.

435.00

16

Fuse

No

14.30

17

Gunpowder

Kg

110.00

18

Kaserde Sand (For Morter lining Work) At Source

Cum

19

Liquid Chlorine 900 Kg.tonner (At Site includind loading


unloading and transportation)

MT.

1092.00
14715.00

20

Lubricant oil

Ltr.

241.50

21

M.S. angle (50mmX50mmX6mm)

Kg.

48.30

22

M.S.Bars

M.T.

48000.00

23

M.S.Bars

Kg.

48.00

24

M.S. flats (40 mm X 3 mm)

Kg.

48.30

25

M.S. plates

Kg.

49.00

26

Mild steel grill ready

Kg.

69.00

27

Mild steel grilled railing

Kg.

69.00

28

Mobile oil

Ltr.

225.00

29

Murum

Cum

275.00

30

Nails

Kg.

31

Nut-bolts

Kg.

85.00

32

Oxigen Gas Refil

No

340.00

33

Plywood Commercial 12 mm thick for centering

Sqm.

730.00

34

Polling boards

Cum.

19800.00

35

R.S. joists,channels,etc.

MT.

48875.00

36

Rapid Sand Gravity Filter Gravel at source

Cum

Cum.

650.00

22.00
800.00

65.00

1035.00

Sr.No.

Description

Unit
Cum.

Rate ( in Rs.)
2012-2013

37

Rapid Sand Gravity Filter Media at


source(Godhra/Gokak,Kanhan,Yesgi Sand)

38

Ready mixed lead / zinc paint

Ltr.

195.00

39

Ready mixed oil paint

Ltr.

231.00

40

Ready mixed primer for steel

Ltr.

154.00

41

Rubber gasket (8mm thick)

Kg.

94.00

42

Rubble

Cum

385.00

43

Sand

Cum

977.00

44

Spun yarn

45

Stone aggregate - 10 mm dia

Cum

850.00

46

Stone aggregate - 20 mm dia

Cum

800.00

47

Stone aggregate - 40 mm dia

Cum

48

Structural Steel

MT

48875.00

49

TCL(Bleaching Powder)Grade I in 25 kg. Bags

Kg.

25.00

50

Teak wood

Cum.

72000.00

51

Tor steel

M.T.

48300.00

52

Walling(100mm X 100mm)

Cum.

16500.00

53

Welding Rod having weight 5.25 Kg

Box

1370.00

54

White cement

Kg.

30.00

55

White lead

Kg.

150.00

56

Wire

Kg.

65.00

kg.

1035.00

95.00

747.00

SECTION - B : LABOUR AND MACHINERY


Sr.No.

Description

Unit

Rate ( in Rs.)
2012-2013

Assistant fitter

No

327.00

Bandhani

No

327.00

Bhisti (with pakhal)

No

260.00

Black smith ( II nd class)

No

303.00

Breaker

No

315.00

Carpenter ( 1 st class)

No

394.00

Carpenter ( 2 nd class)

No

327.00

Chaiseller

No

315.00

Computer operator(Data entry oprator)

No

424.00

10

Electrcian

No

363.00

11

Excavator

No

278.00

12

Fitter ( 1 st class)

No

375.00

13

Glazier

No

278.00

14

Helper

No

260.00

15

Hole driller

No

285.00

16

Mali

No

260.00

17

Mason ( I st class)

No

394.00

18

Mason ( II nd class)

No

285.00

19

Mazdoor (female)

No

260.00

20

Mazdoor (heavy)

No

285.00

21

Mazdoor ( light)

No

260.00

22

Mazdoor (male)

No

260.00

23

Maistry

No

315.00

24

Mukadam

No

315.00

25

Painter (for colouring)

No

315.00

26

Painter

No

303.00

27

Painter for epoxy paint

No

327.00

28

Plumber

No

339.00

29

Polisher

No

315.00

30

Pump driver

No

303.00

31

Stone cutter or dresser

No

339.00

Sr.No.

Description

Unit

Rate ( in Rs.)
2012-2013

32

Tile layer

No

399.00

33

Tile turner

No

303.00

34

Vehicle Driver ( Light )

No

339.00

35

Welder

No

394.00

36

Welder for Pipe-line

No

290.00

37

White washer

No

303.00

38

Wireman

No

285.00

MACHINERY
Sr.No.

Description

Unit

De sludging/ De silting pump

Day

Jeep hire charges with driver and fuel


(Upto 300 KM.)
Pipe cutter with operator

Day

3
4
5

Day

Rate ( in Rs.)
2012-2013
2400
3000

Day
BHP/Day

1250
510
170

Day

2500

Rent charges of chain pully block with tripod


Rent charges for pump exculding oprator
& excluding fuel
Rent of mechanical mixer with fuel and crew

Rent of vibrator with fuel and crew

Day

900

Plate belnder

Day

1000

Rent for welding set with electric set

Day

1200

10

Rent for welding set with generator set

Day

2400

11

Rent for Compressor with fuel

Day

2550

12

Rent for Concrete breaker & Compressor

Day

2750

13

Rent for poclain

HR

2300

14

Rent for Crane

HR

1400

15

Rent for JCB

HR

1100

16

Truck hire charges upto 20 km

Day

2650

17

Truck hire charges for 20 km to 50 km

Day

2400

18

Truck hire charges for 50 km & above

Day

2150

SECTION - C : TRANSPORTATION

STATEMENT I

Sr.
No.

Item of work

Unit

Collecting the
railway receipt
etc & unloading
the consignment
from railway
wagon & keeping
on railway
platform
consignment
booked in.

M.T.

(A) MANUAL HANDLING


(Weight upto & including 300 kg.)
1 C.I. / D.I. /M.S./H.D.P.E. pipes of all classes
upto & including 200 mm dia. Pipes of any
length.
2 R.C.C. pipes of all classes upto & including
350 mm dia.
3 A.C. pipes of all classes & dia.
4 P.V.C. pipes of all classes & dia.
5 All other materials such as C.I. Specials of
individual weight upto 300 kg.
6 Mild steel / for steel / R.S.J.
7 Cement / bleaching powder / alum.
(Materials
(B) CRANE HANDLING
having individual weight above 300 kg.)
1 C.I./D.I./B.W.S.C./ M.S./ R.C.C. pipes of all
classes having individual weight more than
300 kg. & alsoother heavy materials, valves,
machinery having individual weight more than
300 kg.

2012-2013

Loading
the material
into truck
from
department
al store or
site of
work.

Unloading
the material
from truck
including
stacking in
department
al stores or
site of
work.

297.00

365.00

94.00

94.00

M.T.

297.00

365.00

94.00

94.00

M.T.
M.T.
M.T.

157.00
157.00
297.00

221.00
221.00
365.00

56.00
56.00
94.00

56.00
56.00
94.00

M.T.
M.T.

187.00
91.00

253.00
137.00

141.00
70.00

141.00
70.00

M.T.

201.00

254.00

181.00

181.00

Lifting the
material
from
railway
platform,
loading
Unloading
into truck.

1)The above rates in col. 1 to 5 are applicable only for Railway clearence purpose and not for other carting.

2) The rates given in col. 6 to 7 shall be adopted for estimate purpose only, however actual quotations / D- tender will
prevail.

3) Irrespective of supply of C.I./D.I. Pipes as per rate contract when pipes are directly supplied by the firms by road
railway freight upto destination station and carting as per schedule from Railway Station to work site is allowed In such
cases rate of Mathadi Kamgar shall not be applicable for carting and normal loading, unloading carting shall be
allowed.

STATEMENT II

Including loading, unloading and stacking


Lead
in km

1
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
6
7
8
9
10
15
20
25
30
35
40
45
50
60
70
80
90
100

Av.
Speed

2
15
16
16.5
17
17.25
17.5
17.75
18
18.25
18.5
18.75
19
19.183
19.6
20
25
25
25
25
30
30
30
30
30
30
30
30
40

No. of
Trips(N)=
8/ ((2L/S)
+1)
3
7.5
7.11
6.77
6.48
6.2
5.96
5.74
5.54
5.36
5.19
4.88
4.61
4.36
4.17
4
3.64
3.08
2.67
2.35
2.4
2.18
2
1.85
1.6
1.41
1.26
1.14
1.33

Km.
Done
(2NL+6)

4
13.5
20.22
26.31
31.92
37
41.76
46.18
50.32
54.24
57.9
64.56
70.54
75.76
81.06
86
115.2
129.2
139.5
147
174
180.4
186
191
198
203.4
207.6
211.2
272

Litres of
diesel
cons
umed
5
4.5
6.74
8.77
10.64
12.33
13.92
15.39
16.77
18.08
19.3
21.52
23.51
25.25
27.02
28.67
38.4
43.07
46.5
49
58
60.13
62
63.67
66
67.8
69.2
70.4
90.67

cost of
diesel @
52.35 / lit

6
235.58
352.84
459.11
557
645.48
728.71
805.67
877.91
946.49
1010.36
1126.57
1230.75
1321.84
1414.5
1500.87
2010.24
2254.71
2434.28
2565.15
3036.3
3147.81
3245.7
3333.12
3455.1
3549.33
3622.62
3685.44
4746.57

Lit. of
Mobile
oil consumed
7
0.096
0.144
0.188
0.228
0.264
0.298
0.33
0.359
0.387
0.414
0.461
0.504
0.541
0.579
0.614
0.823
0.923
0.996
1.05
1.243
1.289
1.329
1.364
1.414
1.453
1.483
1.509
1.943

cost of
M.Oil @
225/lit

cost of 6
mazdoor
/day

8
21.6
32.4
42.3
51.3
59.4
67.05
74.25
80.78
87.08
93.15
103.73
113.4
121.73
130.28
138.15
185.18
207.68
224.1
236.25
279.68
290.03
299.03
306.9
318.15
326.93
333.68
339.53
437.18

9
1923.75
1923.75
1923.75
1923.75
1923.75
1923.75
1923.75
1923.75
1923.75
1923.75
1923.75
1923.75
1923.75
1923.75
1923.75
1923.75
1923.75
1923.75
1923.75
1923.75
1923.75
1923.75
1923.75
1923.75
1923.75
1923.75
1923.75
1923.75

Hire
charges
of truck
Rs. Per
day
10
2650
2650
2650
2650
2650
2650
2650
2650
2650
2650
2650
2650
2650
2650
2650
2650
2650
2400
2400
2400
2400
2400
2400
2150
2150
2150
2150
2150

Total cost Add 10%


Total
(6+8+
overhead 11+12
9+10)
charges

11
4830.93
4958.99
5075.16
5182.05
5278.63
5369.51
5453.67
5532.44
5607.32
5677.26
5804.05
5917.9
6017.32
6118.53
6212.77
6769.17
7036.14
6982.13
7125.15
7639.73
7761.59
7868.48
7963.77
7847
7950.01
8030.05
8098.72
9257.5

12
13
483.09 5314.02
495.9 5454.89
507.52 5582.68
518.21 5700.26
527.86 5806.49
536.95 5906.46
545.37 5999.04
553.24 6085.68
560.73 6168.05
567.73 6244.99
580.41 6384.46
591.79 6509.69
601.73 6619.05
611.85 6730.38
621.28 6834.05
676.92 7446.09
703.61 7739.75
698.21 7680.34
712.52 7837.67
763.97
8403.7
776.16 8537.75
786.85 8655.33
796.38 8760.15
784.7
8631.7
795 8745.01
803.01 8833.06
809.87 8908.59
925.75 10183.25

cost per
trip
(13/3)

14
708.54
767.21
824.62
879.67
936.53
991.02
1045.13
1098.5
1150.76
1203.27
1308.29
1412.08
1518.13
1614
1708.51
2045.63
2512.91
2876.53
3335.18
3501.54
3916.4
4327.67
4735.22
5394.81
6202.13
7010.37
7814.55
7656.58

Lead
in km

Av.
Speed

125
150
175
200
250
300
400
500
600
700
800
900
1000
Note:

No. of
Trips(N)=
8/ ((2L/S)
+1)
40
40
40
40
40
45
45
45
45
45
45
45
45

1.1
0.94
0.82
0.73
0.59
0.56
0.43
0.34
0.29
0.25
0.22
0.2
0.18

Km.
Done
(2NL+6)

281
288
293
298
301
342
350
346
354
356
358
366
366

Litres of
diesel
cons
umed
93.67
96
97.67
99.33
100.33
114
116.67
115.33
118
118.67
119.33
122
122

cost of
Lit. of
diesel @ Mobile
52.35.0 / lit oil consumed
4903.62
5025.6
5113.02
5199.93
5252.28
5967.9
6107.67
6037.53
6177.3
6212.37
6246.93
6386.7
6386.7

2.007
2.057
2.093
2.129
2.15
2.443
2.5
2.471
2.529
2.543
2.557
2.614
2.614

cost of
M.Oil @
225/lit

cost of 6
mazdoor
/day

451.58
462.83
470.93
479.03
483.75
549.68
562.5
555.98
569.03
572.18
575.33
588.15
588.15

1923.75
1808.33
1577.48
1404.34
1135.01
1077.3
827.21
654.08
557.89
480.94
423.23
384.75
346.28

Hire
Total cost Add 10%
Total
cost per
charges
(6+8+
overhead 11+12
trip
of truck
9+10)
charges
(13/3)
Rs. Per
day
2150 9428.95
942.9 10371.85 9428.95
2150 9446.76
944.68 10391.44 11054.72
2150 9311.43
931.14 10242.57 12490.94
2150
9233.3
923.33 10156.63 13913.19
2150 9021.04
902.1 9923.14 16818.88
2150 9744.88
974.49 10719.37 19141.73
2150 9647.38
964.74 10612.12 24679.35
2150 9397.59
939.76 10337.35 30403.97
2150 9454.22
945.42 10399.64 35860.83
2150 9415.49
941.55 10357.04 41428.16
2150 9395.49
939.55 10335.04 46977.45
2150
9509.6
950.96 10460.56 52302.8
2150 9471.13
947.11 10418.24 57879.11

1)

No. of trips in a working of 8 hours N=8 / (2(L+S) + 1) where L = Lead in km


and S = speed, 1 hour is allowed for loading

2)

Consumption of diesel taken as 3 km / litre

3)

Consumption of Mobile oil taken as 140 km / litre

4)

In col. 4, 6 hours has been added for movement from


parking place to duty and back

5)

Cost of diesel @52.35/ litre and cost of mobile @ Rs 225/litre


Hire charges for truck Rs 2650 / Day upto 20 KM , Rs 2400/ Day from 20 to 50 KM, & Rs 2150/Day from 50 KM and above
Labour required for loading unloading and stacking after the
No. of trips reduced below 1 is factorised with actual number of trip.

6)

STATEMENT III

Excluding loading, unloading and stacking


Lead
in km

1
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
6
7
8
9
10
15
20
25
30
35
40
45
50
60
70
80
90

Av.
Speed

2
15
16
16.5
17
17.25
17.5
17.75
18
18.25
18.5
18.75
19
19.183
19.6
20
25
25
25
25
30
30
30
30
30
30
30
30

No. of
Trips(N)=
8/ ((2L/S)
+1)

3
7.5
7.11
6.77
6.48
6.2
5.96
5.74
5.54
5.36
5.19
4.88
4.61
4.36
4.17
4
3.64
3.08
2.67
2.35
2.4
2.18
2
1.85
1.6
1.41
1.26
1.14

Km.
Done
(2NL+6)

4
13.5
20.22
26.31
31.92
37
41.76
46.18
50.32
54.24
57.9
64.56
70.54
75.76
81.06
86
115.2
129.2
139.5
147
174
180.4
186
191
198
203.4
207.6
211.2

Litres of
diesel
cons
umed

5
4.5
6.74
8.77
10.64
12.33
13.92
15.39
16.77
18.08
19.3
21.52
23.51
25.25
27.02
28.67
38.4
43.07
46.5
49
58
60.13
62
63.67
66
67.8
69.2
70.4

cost of
diesel @
52.35 / lit

6
235.58
352.84
459.11
557
645.48
728.71
805.67
877.91
946.49
1010.36
1126.57
1230.75
1321.84
1414.5
1500.87
2010.24
2254.71
2434.28
2565.15
3036.3
3147.81
3245.7
3333.12
3455.1
3549.33
3622.62
3685.44

Lit. of
Mobile
oil consumed

7
0.096
0.144
0.188
0.228
0.264
0.298
0.33
0.359
0.387
0.414
0.461
0.504
0.541
0.579
0.614
0.823
0.923
0.996
1.05
1.243
1.289
1.329
1.364
1.414
1.453
1.483
1.509

cost of
M.Oil @
225/lit

cost of 6
mazdoor

Hire
charges
of truck
Rs. Per
day

/day

8
21.6
32.4
42.3
51.3
59.4
67.05
74.25
80.78
87.08
93.15
103.73
113.4
121.73
130.28
138.15
185.18
207.68
224.1
236.25
279.68
290.03
299.03
306.9
318.15
326.93
333.68
339.53

9
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

10
2650
2650
2650
2650
2650
2650
2650
2650
2650
2650
2650
2650
2650
2650
2650
2650
2650
2400
2400
2400
2400
2400
2400
2150
2150
2150
2150

Total cost Add 10% Total


(6+8+
overhead 11+12
9+10)
charges

11
2907.18
3035.24
3151.41
3258.3
3354.88
3445.76
3529.92
3608.69
3683.57
3753.51
3880.3
3994.15
4093.57
4194.78
4289.02
4845.42
5112.39
5058.38
5201.4
5715.98
5837.84
5944.73
6040.02
5923.25
6026.26
6106.3
6174.97

12
290.72
303.52
315.14
325.83
335.49
344.58
352.99
360.87
368.36
375.35
388.03
399.42
409.36
419.48
428.9
484.54
511.24
505.84
520.14
571.6
583.78
594.47
604
592.33
602.63
610.63
617.5

13
3197.9
3338.76
3466.55
3584.13
3690.37
3790.34
3882.91
3969.56
4051.93
4128.86
4268.33
4393.57
4502.93
4614.26
4717.92
5329.96
5623.63
5564.22
5721.54
6287.58
6421.62
6539.2
6644.02
6515.58
6628.89
6716.93
6792.47

cost per
trip
(13/3)

14
426.39
469.59
512.05
553.11
595.22
635.96
676.47
716.53
755.96
795.54
874.66
953.05
1032.78
1106.54
1179.48
1464.27
1825.85
2083.98
2434.7
2619.83
2945.7
3269.6
3591.36
4072.24
4701.34
5330.9
5958.31

Lead
in km

100
125
150
175
200
250
300
400
500
600
700
800
900
1000

Av.
Speed

No. of
Trips(N)=
8/ ((2L/S)
+1)
40
40
40
40
40
40
45
45
45
45
45
45
45
45

1.33
1.1
0.94
0.82
0.73
0.59
0.56
0.43
0.34
0.29
0.25
0.22
0.2
0.18

Km.
Done
(2NL+6)

272
281
288
293
298
301
342
350
346
354
356
358
366
366

Litres of
diesel
cons
umed
90.67
93.67
96
97.67
99.33
100.33
114
116.67
115.33
118
118.67
119.33
122
122

cost of
diesel @
52.35 / lit

4746.57
4903.62
5025.6
5113.02
5199.93
5252.28
5967.9
6107.67
6037.53
6177.3
6212.37
6246.93
6386.7
6386.7

Lit. of
Mobile
oil consumed
1.943
2.007
2.057
2.093
2.129
2.15
2.443
2.5
2.471
2.529
2.543
2.557
2.614
2.614

cost of
M.Oil @
225/lit

cost of 6
mazdoor
/day

437.18
451.58
462.83
470.93
479.03
483.75
549.68
562.5
555.98
569.03
572.18
575.33
588.15
588.15

0
0
0
0
0
0
0
0
0
0
0
0
0
0

Hire
Total cost Add 10% Total
charges
(6+8+
overhead 11+12
of truck
9+10)
charges
Rs. Per
day
2150 7333.75
733.38 8067.13
2150
7505.2
750.52 8255.72
2150 7638.43
763.84 8402.27
2150 7733.95
773.4 8507.35
2150 7828.96
782.9 8611.86
2150 7886.03
788.6 8674.63
2150 8667.58
866.76 9534.34
2150 8820.17
882.02 9702.19
2150 8743.51
874.35 9617.86
2150 8896.33
889.63 9785.96
2150 8934.55
893.46 9828.01
2150 8972.26
897.23 9869.49
2150 9124.85
912.49 10037.34
2150 9124.85
912.49 10037.34

cost per
trip
(13/3)

6065.51
7505.2
8938.59
10374.82
11797.07
14702.76
17025.61
22563.23
28287.82
33744.69
39312.04
44861.32
50186.7
55763

STATEMENT IV
Including loading, unloading and stacking
Lead in km Cost / trip

1
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
6
7
8
9
10
15
20
25
30
35
40
45
50
60
70
80

Lime murum Earth


building
rubbish

Manure or
sludge

2
3
4
5
Pay load
6.0 cum
4.8 cum
5.52 cum
708.54
118.09
147.61
128.36
767.21
127.87
159.84
138.99
824.62
137.44
171.8
149.39
879.67
146.61
183.26
159.36
936.53
156.09
195.11
169.66
991.02
165.17
206.46
179.53
1045.13
174.19
217.74
189.34
1098.5
183.08
228.85
199
1150.76
191.79
239.74
208.47
1203.27
200.55
250.68
217.98
1308.29
218.05
272.56
237.01
1412.08
235.35
294.18
255.81
1518.13
253.02
316.28
275.02
1614
269
336.25
292.39
1708.51
284.75
355.94
309.51
2045.63
340.94
426.17
370.59
2512.91
418.82
523.52
455.24
2876.53
479.42
599.28
521.11
3335.18
555.86
694.83
604.2
3501.54
583.59
729.49
634.34
3916.4
652.73
815.92
709.49
4327.67
721.28
901.6
784
4735.22
789.2
986.5
857.83
5394.81
899.14
1123.92
977.32
6202.13
1033.69
1292.11
1123.57
7010.37
1168.4
1460.49
1269.99

Excavated Sand
rock
stone
aggregate
40 mm &
below
6
7
3.0 cum
5.75 cum
236.18
123.22
255.74
133.43
274.87
143.41
293.22
152.99
312.18
162.87
330.34
172.35
348.38
181.76
366.17
191.04
383.59
200.13
401.09
209.26
436.1
227.53
470.69
245.58
506.04
264.02
538
280.7
569.5
297.13
681.88
355.76
837.64
437.03
958.84
500.27
1111.73
580.03
1167.18
608.96
1305.47
681.11
1442.56
752.64
1578.41
823.52
1798.27
938.23
2067.38
1078.63
2336.79
1219.19

Aggregate Soling
40 mm & stone
above

Concrete
block
(form)

Timber

8
9
10
11
5.5 cum
4.7 cum
6.0 cum
5.0 cum
128.83
150.75
118.09
141.71
139.49
163.24
127.87
153.44
149.93
175.45
137.44
164.92
159.94
187.16
146.61
175.93
170.28
199.26
156.09
187.31
180.19
210.86
165.17
198.2
190.02
222.37
174.19
209.03
199.73
233.72
183.08
219.7
209.23
244.84
191.79
230.15
218.78
256.01
200.55
240.65
237.87
278.36
218.05
261.66
256.74
300.44
235.35
282.42
276.02
323.01
253.02
303.63
293.45
343.4
269
322.8
310.64
363.51
284.75
341.7
371.93
435.24
340.94
409.13
456.89
534.66
418.82
502.58
523.01
612.03
479.42
575.31
606.4
709.61
555.86
667.04
636.64
745.01
583.59
700.31
712.07
833.28
652.73
783.28
786.85
920.78
721.28
865.53
860.95
1007.49
789.2
947.04
980.87
1147.83
899.14 1078.96
1127.66
1319.6
1033.69 1240.43
1274.61
1491.57
1168.4 1402.07

Lead in km Cost / trip

90
100
125
150
175
200
250
300
400
500
600
700
800
900
1000

7814.55
7656.58
9428.95
11054.72
12490.94
13913.19
16818.88
19141.73
24679.35
30403.97
35860.83
41428.16
46977.45
52302.8
57879.11

Lime murum Earth


building
rubbish

1302.43
1628.03
1276.1
1595.12
1571.49
1964.36
1842.45
2303.07
2081.82
2602.28
2318.87
2898.58
2803.15
3503.93
3190.29
3987.86
4113.23
5141.53
5067.33
6334.16
5976.81
7471.01
6904.69
8630.87
7829.58
9786.97
8717.13 10896.42
9646.52 12058.15

Manure or
sludge

1415.68
1387.06
1708.14
2002.67
2262.85
2520.51
3046.9
3467.7
4470.9
5507.97
6496.53
7505.1
8510.41
9475.14
10485.35

Excavated Sand
rock
stone
aggregate
40 mm &
below
2604.85
1359.05
2552.19
1331.58
3142.98
1639.82
3684.91
1922.56
4163.65
2172.34
4637.73
2419.69
5606.29
2925.02
6380.58
3329
8226.45
4292.06
10134.66
5287.65
11953.61
6236.67
13809.39
7204.9
15659.15
8169.99
17434.27
9096.14
19293.04 10065.93

Aggregate Soling
40 mm & stone
above

1420.83
1392.11
1714.35
2009.95
2271.08
2529.67
3057.98
3480.31
4487.15
5527.99
6520.15
7532.39
8541.35
9509.6
10523.47

1662.67
1629.06
2006.16
2352.07
2657.65
2960.25
3578.49
4072.71
5250.93
6468.93
7629.96
8814.5
9995.2
11128.26
12314.7

Concrete
block
(form)

Timber

1302.43 1562.91
1276.1 1531.32
1571.49 1885.79
1842.45 2210.94
2081.82 2498.19
2318.87 2782.64
2803.15 3363.78
3190.29 3828.35
4113.23 4935.87
5067.33 6080.79
5976.81 7172.17
6904.69 8285.63
7829.58 9395.49
8717.13 10460.56
9646.52 11575.82

STATEMENT V

Including loading, unloading and stacking


Empty
cement
bags

Lead in
km

Cost / trip

Cement
stone block,
GI CI CC AC
Pipes below
120 mm dia

Steam coal
Tar
bitumenn
Asphalt
roofing felt
& Flooring
Asphalt
etc.

Matting
thatching
bambu
ceiling
board
rubber
PVC pipes
fittings

Sheet &
plate glass
in packs
Paints &
Distemper
s AC
Sheets &
fittings
iron
fittings
and iron
sheets

Bricks
modular
bricks &
Traditional
bricks

Tiles half
round tiles
& Roofing
tiles
cement
flooring
tiles

Glass
blocks
(hollow)
200x200
x120 mm

2
Pay load

3
7.0 Mt

4
4.5 MT

5
5.5 MT

6
3.0 MT

7
7.0 MT

8
3500 No.

9
3200 No.

10
11
1000 0No. 2000 No.

per 1 M.T.

per 1 M.T.

per 1 M.T.

per 1 M.T.

per 1 M.T.

per 1000
Nos.

per 1000
Nos.

per 1000
Nos.

0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
6
7
8
9
10
15
20
25

708.54
767.21
824.62
879.67
936.53
991.02
1045.13
1098.5
1150.76
1203.27
1308.29
1412.08
1518.13
1614
1708.51
2045.63
2512.91
2876.53

101.22
109.6
117.8
125.67
133.79
141.57
149.3
156.93
164.39
171.9
186.9
201.73
216.88
230.57
244.07
292.23
358.99
410.93

157.45
170.49
183.25
195.48
208.12
220.23
232.25
244.11
255.72
267.39
290.73
313.8
337.36
358.67
379.67
454.58
558.42
639.23

128.83
139.49
149.93
159.94
170.28
180.19
190.02
199.73
209.23
218.78
237.87
256.74
276.02
293.45
310.64
371.93
456.89
523.01

236.18
255.74
274.87
293.22
312.18
330.34
348.38
366.17
383.59
401.09
436.1
470.69
506.04
538
569.5
681.88
837.64
958.84

101.22
109.6
117.8
125.67
133.79
141.57
149.3
156.93
164.39
171.9
186.9
201.73
216.88
230.57
244.07
292.23
358.99
410.93

202.44
219.2
235.61
251.33
267.58
283.15
298.61
313.86
328.79
343.79
373.8
403.45
433.75
461.14
488.15
584.47
717.97
821.87

221.42
239.75
257.69
274.9
292.67
309.69
326.6
343.28
359.61
376.02
408.84
441.28
474.42
504.38
533.91
639.26
785.28
898.92

70.85
76.72
82.46
87.97
93.65
99.1
104.51
109.85
115.08
120.33
130.83
141.21
151.81
161.4
170.85
204.56
251.29
287.65

per 1000
Nos.

354.27
383.61
412.31
439.84
468.27
495.51
522.57
549.25
575.38
601.64
654.15
706.04
759.07
807
854.26
1022.82
1256.46
1438.27

1
30
35
40
45
50
60
70
80
90
100
125
150
175
200
250
300
400
500
600
700
800
900
1000

2
3335.18
3501.54
3916.4
4327.67
4735.22
5394.81
6202.13
7010.37
7814.55
7656.58
9428.95
11054.72
12490.94
13913.19
16818.88
19141.73
24679.35
30403.97
35860.83
41428.16
46977.45
52302.8
57879.11

3
4
476.45
741.15
500.22
778.12
559.49
870.31
618.24
961.7
676.46
1052.27
770.69
1198.85
886.02
1378.25
1001.48
1557.86
1116.36
1736.57
1093.8
1701.46
1346.99
2095.32
1579.25
2456.6
1784.42
2775.76
1987.6
3091.82
2402.7
3737.53
2734.53
4253.72
3525.62
5484.3
4343.42
6756.44
5122.98
7969.07
5918.31
9206.26
6711.06 10439.43
7471.83 11622.84
8268.44 12862.02

5
606.4
636.64
712.07
786.85
860.95
980.87
1127.66
1274.61
1420.83
1392.11
1714.35
2009.95
2271.08
2529.67
3057.98
3480.31
4487.15
5527.99
6520.15
7532.39
8541.35
9509.6
10523.47

6
1111.73
1167.18
1305.47
1442.56
1578.41
1798.27
2067.38
2336.79
2604.85
2552.19
3142.98
3684.91
4163.65
4637.73
5606.29
6380.58
8226.45
10134.66
11953.61
13809.39
15659.15
17434.27
19293.04

7
476.45
500.22
559.49
618.24
676.46
770.69
886.02
1001.48
1116.36
1093.8
1346.99
1579.25
1784.42
1987.6
2402.7
2734.53
3525.62
4343.42
5122.98
5918.31
6711.06
7471.83
8268.44

8
952.91
1000.44
1118.97
1236.48
1352.92
1541.37
1772.04
2002.96
2232.73
2187.59
2693.99
3158.49
3568.84
3975.2
4805.39
5469.07
7051.24
8686.85
10245.95
11836.62
13422.13
14943.66
16536.89

9
1042.24
1094.23
1223.88
1352.4
1479.76
1685.88
1938.17
2190.74
2442.05
2392.68
2946.55
3454.6
3903.42
4347.87
5255.9
5981.79
7712.3
9501.24
11206.51
12946.3
14680.45
16344.63
18087.22

10
333.52
350.15
391.64
432.77
473.52
539.48
620.21
701.04
781.46
765.66
942.9
1105.47
1249.09
1391.32
1681.89
1914.17
2467.94
3040.4
3586.08
4142.82
4697.75
5230.28
5787.91

11
1667.59
1750.77
1958.2
2163.84
2367.61
2697.41
3101.07
3505.19
3907.28
3828.29
4714.48
5527.36
6245.47
6956.6
8409.44
9570.87
12339.68
15201.99
17930.42
20714.08
23488.73
26151.4
28939.56

STATEMENT VI
Including loading, unloading and stacking
Lead in km Cost / trip

R.C.C. STEEL CYLINDER, R.C PIPES, C.I. PIPES,, UNREINFORCED CEMENT PIPES, PRECAST COCRETE PIPES
100 mm
125 mm
150 mm
200 mm
250 mm
300 mm
300 & 400 450 & 500 600, 700 800, 900
mm
mm
& 750 mm & 1000
mm
Pay load in R
292.8
219.6
183
109.8
80.52
62.22
54.9
29.28
18.30
15
1
2
3
4
5
6
7
8
9
10
11
12
T PER 100 RMT
0.5
708.54
241.99
322.65
387.18
645.3
879.96
1138.77
1290.6
2419.88
3871.8
4723.6
1
767.21
262.03
349.37
419.24
698.73
952.82
1233.06
1397.47
2620.25
4192.4 5114.73
1.5
824.62
281.63
375.51
450.61
751.02
1024.12
1325.33
1502.04
2816.33 4506.12 5497.47
2
879.67
300.43
400.58
480.69
801.16
1092.49
1413.81
1602.31
3004.34 4806.94 5864.47
2.5
936.53
319.85
426.47
511.77
852.94
1163.1
1505.19
1705.88
3198.53 5117.65 6243.53
3
991.02
338.46
451.28
541.54
902.57
1230.77
1592.77
1805.14
3384.63 5415.41
6606.8
3.5
1045.13
356.94
475.92
571.11
951.85
1297.98
1679.73
1903.7
3569.43 5711.09 6967.53
4
1098.5
375.17
500.23
600.27
1000.46
1364.26
1765.51
2000.91
3751.71 6002.73 7323.33
4.5
1150.76
393.02
524.03
628.83
1048.05
1429.16
1849.5
2096.1
3930.19 6288.31 7671.73
5
1203.27
410.95
547.94
657.52
1095.87
1494.37
1933.9
2191.75
4109.53 6575.25
8021.8
6
1308.29
446.82
595.76
714.91
1191.52
1624.8
2102.68
2383.04
4468.2 7149.13 8721.93
7
1412.08
482.27
643.02
771.63
1286.05
1753.7
2269.5
2572.09
4822.68 7716.28 9413.87
8
1518.13
518.49
691.32
829.58
1382.63
1885.41
2439.94
2765.26
5184.87 8295.79 10120.87
9
1614
551.23
734.97
881.97
1469.95
2004.47
2594.02
2939.89
5512.3 8819.67
10760
10
1708.51
583.51
778.01
933.61
1556.02
2121.85
2745.92
3112.04
5835.08 9336.12 11390.07
15
2045.63
698.64
931.53
1117.83
1863.05
2540.52
3287.74
3726.1
6986.44 11178.31 13637.53
20
2512.91
858.23
1144.31
1373.17
2288.62
3120.85
4038.75
4577.25
8582.34 13731.75 16752.73
25
2876.53
982.42
1309.9
1571.87
2619.79
3572.44
4623.16
5239.58
9824.21 15718.74 19176.87
30
3335.18
1139.06
1518.75
1822.5
3037.5
4142.05
5360.3
6075.01 11390.64 18225.03 22234.53
35
3501.54
1195.88
1594.51
1913.41
3189.02
4348.66
5627.68
6378.03 11958.81 19134.1 23343.6
40
3916.4
1337.57
1783.42
2140.11
3566.85
4863.88
6294.44
7133.7 13375.68 21401.09 26109.33
45
4327.67
1478.03
1970.71
2364.85
3941.41
5374.65
6955.43
7882.82 14780.29 23648.47 28851.13
50
4735.22
1617.22
2156.29
2587.55
4312.59
5880.8
7610.45
8625.17
16172.2 25875.52 31568.13
60
5394.81
1842.49
2456.65
2947.98
4913.31
6699.96
8670.54
9826.61
18424.9 29479.84 35965.4
70
6202.13
2118.21
2824.29
3389.14
5648.57
7702.6
9968.06 11297.14 21182.14 33891.42 41347.53
80
7010.37
2394.25
3192.34
3830.8
6384.67
8706.37 11267.07 12769.34 23942.52 38308.03 46735.8

1200 &
1800 MM
5
13
14170.8
15344.2
16492.4
17593.4
18730.6
19820.4
20902.6
21970
23015.2
24065.4
26165.8
28241.6
30362.6
32280
34170.2
40912.6
50258.2
57530.6
66703.6
70030.8
78328
86553.4
94704.4
107896.2
124042.6
140207.4

Lead in km Cost / trip

1
90
100
125
150
175
200
250
300
400
500
600
700
800
900
1000

R.C.C. STEEL CYLINDER, R.C PIPES, C.I. PIPES,, UNREINFORCED CEMENT PIPES, PRECAST COCRETE PIPES
100 mm
125 mm
150 mm
200 mm
250 mm
300 mm
300 & 400 450 & 500 600, 700 800, 900
mm
mm
& 750 mm & 1000
mm
Pay load in R
292.8
219.6
183
109.8
80.52
62.22
54.9
29.28
18.30
15
2
3
4
5
6
7
8
9
10
11
12
7814.55
2668.9
3558.54
4270.25
7117.08
9705.1 12559.55 14234.15 26689.04 42702.46
52097
7656.58
2614.95
3486.6
4183.92
6973.21
9508.92 12305.66 13946.41 26149.52 41839.23 51043.87
9428.95
3220.27
4293.69
5152.43
8587.39 11710.07 15154.21 17174.77
32202.7 51524.32 62859.67
11054.72
3775.52
5034.03
6040.83 10068.05 13729.16 17767.15
20136.1 37755.19 60408.31 73698.13
12490.94
4266.03
5688.04
6825.65 11376.08 15512.84 20075.44 22752.17 42660.31 68256.5 83272.93
13913.19
4751.77
6335.7
7602.84 12671.39 17279.17 22361.28 25342.79 47517.73 76028.36 92754.6
16818.88
5744.15
7658.87
9190.64 15317.74 20887.83 27031.31 30635.48 57441.53 91906.45 112125.9
19141.73
6537.48
8716.63
10459.96 17433.27 23772.64 30764.59 34866.54 65374.76 104599.6 127611.5
24679.35
8428.74 11238.32
13485.98 22476.64 30649.96 39664.66 44953.28
84287.4 134859.8
164529
30403.97
10383.87 13845.16
16614.19 27690.32 37759.53 48865.27 55380.64 103838.7 166141.9 202693.1
35860.83
12247.55 16330.07
19596.08 32660.14 44536.55 57635.54 65320.27 122475.5 195960.8 239072.2
41428.16
14148.96 18865.28
22638.34 37730.56 51450.77 66583.35 75461.13 141489.6 226383.4 276187.7
46977.45
16044.21 21392.28
25670.74 42784.56 58342.59 75502.17 85569.13 160442.1 256707.4
313183
52302.8
17862.98
23817.3
28580.77 47634.61 64956.28 84061.07 95269.22 178629.8 285807.7 348685.3
57879.11
19767.46 26356.61
31627.93 52713.21 71881.66 93023.32 105426.4 197674.6 316279.3 385860.7

1200 &
1800 MM
5
13
156291
153131.6
188579
221094.4
249818.8
278263.8
336377.6
382834.6
493587
608079.4
717216.6
828563.2
939549
1046056
1157582

STATEMENT VII
Including loading, unloading and stacking
STONEWARE PIPES
Lead in
km

Cost/trip

100 mm

150 mm

200 mm

230 mm

250 mm

300 mm

350 mm

400 mm

Pay Load 480 m


240 m
135 m
105 m
84 m
66 m
43 m
27 m
1
2
3
4
5
6
7
8
9
10
Unit Per 100 Rmt
0.5
708.54
147.61
295.23
524.84
674.80
843.50
1073.55
1647.77
2624.22
1
767.21
159.84
319.67
568.30
730.68
913.35
1162.44
1784.21
2841.52
1.5
824.62
171.80
343.59
610.83
785.35
981.69
1249.42
1917.72
3054.15
2
879.67
183.26
366.53
651.61
837.78
1047.23
1332.83
2045.74
3258.04
2.5
936.53
195.11
390.22
693.73
891.93
1114.92
1418.98
2177.98
3468.63
3
991.02
206.46
412.93
734.09
943.83
1179.79
1501.55
2304.70
3670.44
3.5
1045.13
217.74
435.47
774.17
995.36
1244.20
1583.53
2430.53
3870.85
4
1098.50
228.85
457.71
813.70
1046.19
1307.74
1664.39
2554.65
4068.52
4.5
1150.76
239.74
479.48
852.41
1095.96
1369.95
1743.58
2676.19
4262.07
5
1203.27
250.68
501.36
891.31
1145.97
1432.46
1823.14
2798.30
4456.56
6
1308.29
272.56
545.12
969.10
1245.99
1557.49
1982.26
3042.53
4845.52
7
1412.08
294.18
588.37
1045.99
1344.84
1681.05
2139.52
3283.91
5229.93
8
1518.13
316.28
632.55
1124.54
1445.84
1807.30
2300.20
3530.53
5622.70
9
1614.00
336.25
672.50
1195.56
1537.14
1921.43
2445.45
3753.49
5977.78
10
1708.51
355.94
711.88
1265.56
1627.15
2033.94
2588.65
3973.28
6327.81
15
2045.63
426.17
852.35
1515.28
1948.22
2435.27
3099.44
4757.28
7576.41
20
2512.91
523.52
1047.05
1861.41
2393.25
2991.56
3807.44
5843.98
9307.07
25
2876.53
599.28
1198.55
2130.76
2739.55
3424.44
4358.38
6689.60 10653.81
30
3335.18
694.83
1389.66
2470.50
3176.36
3970.45
5053.30
7756.23 12352.52
35
3501.54
729.49
1458.98
2593.73
3334.80
4168.50
5305.36
8143.12 12968.67
40
3916.40
815.92
1631.83
2901.04
3729.90
4662.38
5933.94
9107.91 14505.19
45
4327.67
901.60
1803.20
3205.68
4121.59
5151.99
6557.08 10064.35 16028.41
50
4735.22
986.50
1973.01
3507.57
4509.73
5637.17
7174.58 11012.14 17537.85

Lead in
km
1
60
70
80
90
100
125
150
175
200
250
300
400
500
600
700
800
900
1000

Cost/trip

100 mm

150 mm

200 mm

230 mm

250 mm

300 mm

Pay Load

480 m

240 m

135 m

105 m

84 m

66 m

2
5394.81
6202.13
7010.37
7814.55
7656.58
9428.95
11054.72
12490.94
13913.19
16818.88
19141.73
24679.35
30403.97
35860.83
41428.16
46977.45
52302.80
57879.11

3
1123.92
1292.11
1460.49
1628.03
1595.12
1964.36
2303.07
2602.28
2898.58
3503.93
3987.86
5141.53
6334.16
7471.01
8630.87
9786.97
10896.42
12058.15

4
2247.84
2584.22
2920.99
3256.06
3190.24
3928.73
4606.13
5204.56
5797.16
7007.87
7975.72
10283.06
12668.32
14942.01
17261.73
19573.94
21792.83
24116.30

5
3996.16
4594.17
5192.87
5788.56
5671.54
6984.41
8188.68
9252.55
10306.07
12458.43
14179.06
18281.00
22521.46
26563.58
30687.53
34798.11
38742.81
42873.41

6
5137.91
5906.79
6676.54
7442.43
7291.98
8979.95
10528.30
11896.13
13250.66
16017.98
18230.22
23504.14
28956.16
34153.17
39455.39
44740.43
49812.19
55122.96

7
6422.39
7383.49
8345.68
9303.04
9114.98
11224.94
13160.38
14870.17
16563.32
20022.48
22787.77
29380.18
36195.20
42691.46
49319.24
55925.54
62265.24
68903.70

350 mm

400 mm

43 m
27 m
8
9
10
8173.95 12546.07 19980.78
9397.17 14423.56 22970.85
10621.77 16303.19 25964.33
11840.23 18173.37 28942.78
11600.88 17806.00 28357.70
14286.29 21927.79 34922.04
16749.58 25708.65 40943.41
18925.67 29048.70 46262.74
21080.59 32356.26 51530.33
25483.15 39113.67 62292.15
29002.62 44515.65 70895.30
37392.95 57393.84 91405.00
46066.62 70706.91 112607.30
54334.59 83397.28 132817.89
62769.94 96344.56 153437.63
71177.95 109249.88 173990.56
79246.67 121634.42 193714.07
87695.62 134602.58 214367.07

STATEMENT VIII
Including loading, unloading and stacking
Lead in
km

Cost per
trip

0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
6
7
8
9
10
15
20
25
30
35
40
45
50
60
70
80
90
100
125
150
175
200
250
300
400
500
600
700
800
900
1000

708.54
767.21
824.62
879.67
936.53
991.02
1045.13
1098.5
1150.76
1203.27
1308.29
1412.08
1518.13
1614
1708.51
2045.63
2512.91
2876.53
3335.18
3501.54
3916.4
4327.67
4735.22
5394.81
6202.13
7010.37
7814.55
7656.58
9428.95
11054.72
12490.94
13913.19
16818.88
19141.73
24679.35
30403.97
35860.83
41428.16
46977.45
52302.8
57879.11

Cement Steel pay


Bulk
M.S.Bar
pay load
load
Asphalt in 10.0 MT
10.00 MT 10.00 MT Bouzer pay
load 4.50
MT

Sand
5.75 cum

70.85
76.72
82.46
87.97
93.65
99.10
104.51
109.85
115.08
120.33
130.83
141.21
151.81
161.40
170.85
204.56
251.29
287.65
333.52
350.15
391.64
432.77
473.52
539.48
620.21
701.04
781.46
765.66
942.90
1105.47
1249.09
1391.32
1681.89
1914.17
2467.94
3040.40
3586.08
4142.82
4697.75
5230.28
5787.91

70.85
76.72
82.46
87.97
93.65
99.10
104.51
109.85
115.08
120.33
130.83
141.21
151.81
161.40
170.85
204.56
251.29
287.65
333.52
350.15
391.64
432.77
473.52
539.48
620.21
701.04
781.46
765.66
942.90
1105.47
1249.09
1391.32
1681.89
1914.17
2467.94
3040.40
3586.08
4142.82
4697.75
5230.28
5787.91

157.45
170.49
183.25
195.48
208.12
208.12
232.25
244.11
255.72
267.39
290.73
313.80
337.36
358.67
379.67
454.58
558.42
639.23
741.15
778.12
870.31
961.70
1052.27
1198.85
1378.25
1557.86
1736.57
1701.46
2095.32
2456.60
2775.76
3091.82
3737.53
4253.72
5484.30
6756.44
7969.07
9206.26
10439.43
11622.84
12862.02

70.85
76.72
82.46
87.97
93.65
99.10
104.51
109.85
115.08
120.33
130.83
141.21
151.81
161.40
170.85
204.56
251.29
287.65
333.52
350.15
391.64
432.77
473.52
539.48
620.21
701.04
781.46
765.66
942.90
1105.47
1249.09
1391.32
1681.89
1914.17
2467.94
3040.40
3586.08
4142.82
4697.75
5230.28
5787.91

123.22
133.43
143.41
152.99
162.87
172.35
181.76
191.04
200.13
209.26
227.53
245.58
264.02
280.70
297.13
355.76
437.03
500.27
580.03
608.96
681.11
752.64
823.52
938.23
1078.63
1219.19
1359.05
1331.58
1639.82
1922.56
2172.34
2419.69
2925.02
3329.00
4292.06
5287.65
6236.67
7204.90
8169.99
9096.14
10065.93

STATEMENT IX
Excluding loading, unloading and stacking
Lead in
Cost per
Cement Steel pay
Bulk
km
trip
pay load load 10.00 Asphalt in
10.00 MT
MT
Bouzer pay
load 4.50
MT
1
2
3
4
5
0.5
42.64
42.64
94.75
426.39
1
46.96
46.96
104.35
469.59
1.5
51.21
51.21
113.79
512.05
2
55.31
55.31
122.91
553.11
2.5
59.52
59.52
132.27
595.22
3
63.60
63.60
132.27
635.96
3.5
67.65
67.65
150.33
676.47
4
71.65
71.65
159.23
716.53
4.5
75.60
75.60
167.99
755.96
5
79.55
79.55
176.79
795.54
6
87.47
87.47
194.37
874.66
7
95.31
95.31
211.79
953.05
8
103.28
229.51
1032.78 103.28
9
110.65
110.65
245.90
1106.54
10
117.95
117.95
262.11
1179.48
15
146.43
325.39
1464.27 146.43
20
182.59
405.74
1825.85 182.59
25
208.40
463.11
2083.98 208.40
30
243.47
243.47
541.04
2434.7
35
261.98
582.18
2619.83 261.98
40
294.57
654.60
2945.7 294.57
45
326.96
726.58
3269.6 326.96
50
359.14
359.14
798.08
3591.36
60
407.22
904.94
4072.24 407.22
70
470.13
1044.74
4701.34 470.13
80
533.09
1184.64
5330.9 533.09
90
595.83
1324.07
5958.31 595.83
100
606.55
1347.89
6065.51 606.55
750.52
750.52
1667.82
125
7505.2
150
893.86
1986.35
8938.59 893.86
175
1037.48
2305.52
10374.82 1037.48
200
1179.71
2621.57
11797.07 1179.71
250
1470.28
1470.28
3267.28
14702.76
300
1702.56
1702.56
3783.47
17025.61
400
2256.32
5014.05
22563.23 2256.32
500
2828.78
6286.18
28287.82 2828.78
600
3374.47
3374.47
7498.82
33744.69
700
3931.20
3931.20
8736.01
39312.04
800
4486.13
9969.18
44861.32 4486.13
900
5018.67 11152.60
50186.7 5018.67
1000
5576.30 12391.78
55763 5576.30

Section - E- Excavation
Sr No

Item Description

Unit

Excavation for foundation / pipe trenches in earth, soils of all types,


sand, gravel and soft murum, including removing the excavated
material upto a distance of 50 metres and lifts as below, stacking and
spreading as directed, manual dewatering, preparing the bed for
foundation and excluding backfilling, etc. complete.

Rate
( in Rs.)
2012-2013

(Bd-A-1/259)
Cu.m

134.00

Cu.m

151.00

Lift 0 to 1.5 M

Cu.m

169.00

Add for every additional lift of 1.5 M beyond initial lift of 1.5 M for Item
Nos. 1 to 3
Excavation for foundation / pipe trenches in soft rock and old cement
and lime masonry foundation asphalt road including removing the
excavated material upto a distance of 50 M beyond area and lifts as
below, stacking as directed by Engineer-in-charge, normal
dewatering, preparing the bed for foundation and excluding
backfilling, etc. complete.

Cu.m

13.00

Cu.m

449.00

Cu.m

575.00

Cu.m

749.00

Lift 0 to 1.5 M

Excavation for foundation / pipe trenches in hard murum including


removing the excavated material upto a distace of 50 M and lifts as
below, stacking and spreading as directed by Engineer-in-charge,
normal dewatering, preparing the bed for foundation and excluding
backfilling, etc. complete.
(Bd-A2/259)
Lift 0 to 1.5 M

Excavation for foundation / pipe trenches in hard murum and


boulders, W.B.M. road including removing the excavated material
upto a distance of 50 M beyond the area and lifts as below, stacking
and spreading as directed by Engineer-in-charge, normal dewatreing,
preparing the bed for foundation and excluding backfilling, etc.
complete.
(Bd-A-3/259)

4
5

( Bd-A-4/259)
Lift 0 to 1.5 M

Excavation for foundation / pipe trenches in hard rock by controlled


blasting, including trimming and levelling the bed by chiselling where
necessary and removing the excavated material and stacking it in
measurable heaps within a distance of 50 metres from the area and
lifts as below, normal dewatering, excluding backfilling, etc. complete.
(Bd-A-5/259)
Lift 0 to 1.5 M

Excavation for foundation / pipe trenches in hard rock and concrete


road by chiselling, wedging, line drilling, by mechanical means or by
all means other than blasting including trimming and levelling the bed,
removing the excavated material upto a distance of 50 metres beyond
the area and lifts as below, stacking as directed by Engineer-incharge, normal dewatering, excluding backfilling, etc. complete by all
means.
(Bd-A-1/259)
Lift 0 to 1.50 M

Rate
( in Rs.)
2013-2014

Sr No

Item Description

Excavation for foundation /pipe trenches in Slush Muddy/ Marshy


/Slushy /Soil including use of poclain, labour for dewatering during
execution including removing the excavated material upto a distance
of 50 metres and lifts as below, stacking and spreading as directed,
preparing the bed by cleaning the mud, labour required for execution
for shutterng item but excluding back filling etc. complete. Providing
and fixing shuttering shall be paid separately.

Unit

Rate
( in Rs.)
2012-2013

Lift 0 to 1.5 M

Cu.m

322.00

Add for every additional lift of 1.5 M beyond initial lift of 1.5 M for Item
Nos 5 to 9
HEAD WORKS

Cu.m

22.00

10

Excavation in general in soft material comprising of soft soil, soft


murum, sand, hard murum with boulders in wet or dry condition for
Head Works i.e. Intake Well, Connecting Pipe, Jack Well, Pump
House, Supply Well, etc. for lift 0 to 1.5 M and lead of 150 M including
baricating, gurading, disposing off surplus excavated stuff within a
radius of 0.5 km. as directed by Engineer-in- charge, etc. complete
excluding refilling.

a)

For Head Works on river or dam submergence for initial lift of 0 to 1.5
M
For Head works on nalla or any other site of GSDA for initial Lift of 0
to 1.5M
Add for every additional lift of 1.5 M beyond initial lift of 1.5 M

Cu.m

369.00

Cum

259.00

Cu.m

24.00

Cu.m

779.00

Cum

551.00

Cu.m

24.00

671.00
599.00
599.00

b)
c)

11

Excavation in general in hard material comprising of soft rock, hard


rock, Manjara rock, etc, by blasting / controlled blasting, chiselling as
required in wet or dry condition for Head Works i.e. Intake Well,
Connecting Pipe, Jack Well, Pump House, supply Well, etc. for lift 0
to 1.5 M and lead of 150 M including baricading, guarding, disposing
off surplus excavated stuff within a radius of 0.5 km. as directed by
Engineer-in-charge, excluding refilling.

a)

For Head Works on river or dam sub mergence for initial lift of 0 to 1.5
M
For Head Works on nalla or any other site of GSDA for initial lift of 0
to 1.5 M
Add for each additional lift to 1.5 M beyond initial lift of 1.5 M

b)
c)

12

Excavation in general in soft material comprising of soft soil, soft


murum, sand, hard murum with boulders in wet or dry condition for
Head Works and allied works by well sinking process for average
depth of 12 M and lead of 150 M including shoring, barricading,
guarding, refilling, disposing of surplus excavated stuff as directed by
Engineer-in-charge, etc. complete.

a)

Diameter upto and including 3 M

Cu.m

b)

Diameter more than 3 M

Cu.m

Desilting the Supply Well, Intake Well / Head Works, sump of water
supply/ sewerage works etc. in wet or dry condition including lifts upto
15 M and lead upto 150 M as required beyond the work site, stacking,
spreading, including necessary guarding, etc. complete, as directed
by Engineer-in-charge.

Cu.m

13

Add for every additional lift of 1.5 M beyond initial lift of 15.0 M

14

Dewatering the excavated trenches and pools of water in the building


trenches / pipeline trenches, well works by using pumps and other
devices including disposing off water to safe distance as directed by
Engineer-in-charge (including cost of machinery, labour, fuel), etc.
complete.

Cu.m
Bhp/Hr

20.00
60.00

Rate
( in Rs.)
2013-2014

Sr No

Item Description

Unit

Rate
( in Rs.)
2012-2013

i) The contractor at his request may allowed to start construction of


masonary steining so as not to allow silting of well in oncoming
mansoon and while paying masonary, 25% amount shall be withheld
and released only when excavation to the full depth is completed.
ii) Dewatering : Total dewatering charges are to be proposed in tender
as lumpsum amount and 75% is payable for excavation and 25% is
payable for construction of well / gallery. Out of 75% excavation
breakup shall be as under
25% for last 1 Mtr. Depth.
20% for 2 M depth which just above last 1 M depth.
15% for 2 M depth which just above last 3 M depth.
15% for the rest of depth from water table level
The above conditions will restrict the tendancy of agencies to avoid
deeping of wells etc. to the required depths.

15

Refilling the trenches with available excavated stuff with soft material
first over pipeline and then hard material in 15 cm layers with all leads
and lifts including consolidation, surcharging, etc. complete.

Cu.m

60.00

16

Filling in plinth and floors murum bedding in trenches with approved


murum from excavated materials from foundation 15cm to 20cm
layers including watering and compaction complete.

Cu.m

60.00

17

Filling in plinth and floors / trenches with contractors murum for


bedding in 15cm to 20cm layers including watering and compaction
complete.
Providing dry trap / granite / quartzite / gneiss, rubble stone soling in
15cm to 20 cm thick layers (including hand packing and compacting),
etc. complete.
Providing and filling in sand boxing in pipeline or for foundation with
sand of approved quality including watering compaction, etc.
complete.
Open timbering in trenches of depth more than 1.5 m for shoring and
strutting including use of and waste of all necessary timber works
including walling, strutts, open polling boards/ horizontal sheeting,
runners, etc. as may be necessary and fixing and removal complete.
(Measurements to be taken of the face/area timbered)(NBO Item No.
4-15 page No.59 )

Cu.m

629.00

Cu.m

869.00

Cu.m

869.00

Lift 0 to 1.5 M [ for non-water logged area ]

Sq.m

197.00

Additional per Sqm. for further lifts of 1.5M each.

Sq.m

Lift for 0 to 1.5 M [ For water logged area.]

Sq.m

28.00
216.00

Additional per Sqm. for further lifts of 1.5M each

Sq.m

24.00

18
19
20

a)
b)

Note:- For the trenches with more than 1.5 M depth shoring if
required from G.L. is to be done and is payable from GL.

Rate
( in Rs.)
2013-2014

Section - F- Iron And Structural Steel Work.


Sr No

Item Description

Unit

Providing and fixing mild steel grill work for windows/ventilators of 20


Kg./Sqm. as per drawings including necessary welding and painting
with one coat of anticorrosive paint and two coats of oil painting, etc.
complete.
(Bd-U-1/537)
Providing and fixing mild steel grill railing of 20 Kg./Sqm. with teak
wood hand railing, still and newel posts for staircase and including
fabricating, fixtures, erecting, painting the grill work with approved oil
paint and polishing the hand rail and newel posts with French polish
two coats, etc. complete.
(Bd-U-2 /537)
Providing structural steel work in rolled stanchions fixed with
connecting plates or angle cleats as in main and cross beams, hip and
jack rafters, purlins connecting to truss members and like as per
detailed desings and drawings or as directed by Engineer-in-charge
including cutting, fabricating, hoisting, erecting, fixing in position,
making riveted / bolted /welded connections and one coat of
anticorrosive paints and over it two coats of oil painting, etc. complete.

Sq.m

1537.00

Sq.m

2327.00

(Bd-C-3 /275)
Providing stuctural steel work in single stanchions composed of RSJ,
channel, etc, with caps, bases, mild steel plates, angles, brackets,
cleats, gusset plates, anchor bolts, etc. as per detailed design and
drawing or as directed by Engineer-in-charge including cutting,
fabrication, hoisting, erecting, fixing in position, making riveted/ bolted
/ welded connections and one coats of anticorrosive paint and over it
two coats of oil painting, etc. complete.
(Bd-C-6 /277)
Providing structural steel work in rolled sections like joists, channels,
angles, tees, etc. as per detailed designs and drawings including
fixing in position without connecting plates, braces, etc. and one coat
of anticorrosive paint and over it two coats of oil painting, of approved
quality and shade, etc. complete.
(Bd-C-2 /275)
Providing structural steel work in trusses, other similar trussed purlins
and members with all bracing, gusset plates, etc. as per detailed
design and drawing or as directed by Engineer-in-charge including
cutting, fabricating, hoisting, erecting and fixing in position, making
reveted / bolted / welded connections and one coat of anticorrosive
paint and over it two coat of oil painting, etc. complete.

(Bd-C-8 /278)

Rate
( in Rs.)
2012-2013

M.T

59583.00

M.T

58719.00

M.T

61655.00

M.T

72957.00

Rate
( in Rs.)
2013-2014

Section G - P.C.C.
Sr No

Item Description

Unit

Rate
( in Rs.)
2012-2013

Item No 1 Providing and laying in situ Cement concrete


of trap/granite/quartzite/ gneiss metal for PCC work
below foundation and footing including normal
dewatering,plywood form work, compaction, finishing and
curing, etc, complete.
1 PCC M 100

Cum

3561.00

2 PCC M 150

Cum

4010.00

Rate
( in Rs.)
2013-2014

Section - G- Reinforced Cement Concrete


Sr No

Item Description

Providing and laying in situ Cement concrete of trap/granite/quartzite/


gneiss metal for RCC work in foundation like raft, grillage, strip
foundation and footing of RCC columns and steel stanchions
including normal dewatering,plywood form work, compaction,
finishing and curing, etc, complete. (By weigh batching and mix
design for M-250 and M-300 only. Use of L & T, A.C.C., Ambuja,
Birla Gold, Manikgad, Rajashree, etc. cement is permitted.)

Unit

Rate
( in Rs.)
2012-2013

Excluding M.S. or Tor reinforcement.


a

In RCC M-150

Cu.m

In RCC M-200

Cu.m

In RCC M-250

Cu.m

In RCC M-300

Cu.m

Providing
and
casting
in
situ
Cement
Concrete
of
trap/granite/quartzite/ gneiss metal of approved quality for RCC work
as per detailed drawings and designs or as directed by Engineer-incharge including normal dewatering, plywood form work,bully/steel
prop ups, compaction, finishing the formed surfaces with CM 1:3 of
sufficient minimum thickness if special finish is to be provided and
curing, etc. complete. (By weigh batching and mix design for M-250
and M-300 only. Use of L&T, A.C. C., Ambuja, Birla Gold, Manikgad,
Rajashree, etc. cement is permitted )

For RCC M-150 grade - all types of columns

Cu.m

For RCC M-200 grade - all types of columns.

Cu.m

4828.00
4931.00
5477.00
5716.00

Excluding M.S. or Tor reinforcement.

For RCC M-250 grade - all types of columns.

Cu.m

For RCC M-300 grade - all types of columns.

Cu.m

Providing and casting in situ C. C. of trap / granite / quartzite/ gneiss


metal of approved quality for RCC works as per detailed drawings
and designs or as directed by Engineer-in-charge including normal
dewatering, ,plywood form work,bully/steel prop ups compaction,
finishing the formed surfaces with C. M. 1:3 of sufficient minimum
thickness to give a smooth and even surface wherever nesessary or
roughening if special finish is to be provided and curing, etc.
complete. (By weigh batching and mix design for M-250 and M-300
only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree,
etc. cement is permitted.)

Deleted
6522.00
7068.00
7277.00

Excluding M.S. or Tor reinforcement.


a

For RCC M-150 grade Beams/Braces/Lintels

Cu.m

For RCC M-200 grade Beams/Braces/Lintels

Cu.m

For RCC M-250 grade Beams/Braces/Lintels

Cu.m

For RCC M-300 grade Beams/Braces/Lintels

Cu.m

Deleted
6491.00
7037.00
7277.00

Rate
( in Rs.)
2013-2014

Sr No

Item Description

Providing and casting in situ C. C. of trap/granite/quartzite/ gneiss


metal of approved quality for RCC work as per detailed drawings and
designs or as directed by Engineer-in-charge including normal
dewatering, plywood form work,bully/steel prop ups, compaction,
finishing the formed surfaces with CM 1:3 of sufficient minimum
thickness to give a smooth and even surface wherever necessary or
roughening if special finssh is to be provided and curing, etc.
complete. (By weigh batching and mix design for M-250 and M-300
only. Use fo L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree,
etc. cement is permitted .)

Unit

Rate
( in Rs.)
2012-2013

Excluding M.S. or Tor reinforcement.


a
b
c
d

For RCC M-150 grade Slabs / Landings / Vertical Walls / Waist Slabs
/ Steps for Staircase
For RCC M-200 grade Slabs / Landings / Vertical Walls / Waist Slabs
/ Steps for Staircase
For RCC M-250 grade Slabs / Landings / Vertical Walls / Waist Slabs
/ Steps for Staircase
For RCC M-300 grade Slabs / Landings / Vertical Walls / Waist
Slabs / Steps for Staircase
Providing and casting in situ C. C. of trap/granite/quartzite/ gneiss
metal of approved quality for RCC work as per detailed drawings and
desingns or as directed by Engineer-in-charge including normal
dewatering,plywood form work,bully/steel prop ups, compaction,
finishing the formed surfaces with CM 1:3 of sufficient minimum
thickness to give a smooth and even surface wherever necessary or
roughening if special finish is to be provided and curing, etc.
complete. (By weigh batching and mix design for M-250 and M-300
only. Use of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree,
etc. cement is permitted .)

Cu.m

Deleted

Cu.m

7062.00

Cu.m

7608.00

Cu.m

7848.00

Cu.m

Deleted

Cu.m

7163.00

Cu.m

7709.00

Cum

7949.00

Deleted
7488.00
8034.00
8273.00

Excluding M.S. or Tor reinforcement.


a
b
c
d

For RCC M-150 grade Chajjas / Parapets / Curtain Walls / Partition


Walls / Pardies
For RCC M-200 grade Chajjas / Parapets / Curtain Walls / Partition
Walls / Pardies
For RCC M-250 grade Chajjas / Parapets / Curtain Walls / Partition
Walls / Pardies
For RCC M-300 grade Chajjas / Parapets / Curtain Walls / Partition
Walls / Pardies
Providing and laying in situ R. C. C. of trap/granite/quartzite/ gneiss
metal of approved quality for RCC works of domes as per detailed
drawings and designs approved by Engineer-in-charge including
plywood form work,bully/steel prop ups, finishing, roughening the
surfaces with special finish or plaster to be provided separately,
curing, etc. complete. (By weigh batching and mix design for M-250
and M-300 only. Use of L&T, A.C. C., Ambuja, Birla Gold, Manikgad,
Rajashree, etc. cement is permitted .)
Excluding M.S. or Tor reinforcement.

For RCC M-150 grade - Domes

Cu.m

For RCC M-200 grade - Domes

Cu.m

For RCC M-250 grade - Bottom Domes only

Cu.m

For RCC M-300 grade - Bottom Domes only

Cu.m

Rate
( in Rs.)
2013-2014

Unit

Rate
( in Rs.)
2012-2013

Mild Steel

M.T.

Tor Steel

M.T

57087.00
57087.00
61786.00
7128.00

Sr No

Item Description

Providing and fixing in position steel bar reinforcement of various


diameters for RCC piles, caps, footings, foundation, slabs, beams,
columns, canopies, staircases. newels, chajjas, lintels, pardies,
copings, fins, arches, etc. as per detailed designs, drawings and
schedules; including cutting, bending, hooking the bars, binding with
wires or tack welding and supporting as required, etc. complete.
(including cost of binding wire)

a
b
c

Corrosion Resistant steel (Fe 500)

M.T

Only Fabrication ( Labour ) For all types of steel

M.T

Providing fusion bonded epoxy coating to reinforcement bars as per


ASTM-755 specificaion for a thickness of 175 (+50) microns including
extra cost on account of careful handling, extra cost on account of
using PVC coated binding wire instead of G. I. wire, extra cost on
account of touch-up material supplied by coating agency and repair
work extra cost on account of transportation to and fro from steel
yard at Kalamboli to plant at Daman and Plant at Daman to work site
by trailer, loading, unloading, including all taxes (Central and Local),
etc. complete.

(a)

For reinforcement Diameterwise rates.

8 mm dia.

M.T

10 mm dia.

M.T

12 mm dia.

M.T

16 mm dia.

M.T

20 mm dia.

M.T

25 mm dia.

M.T

28 mm dia.

M.T

32 mm dia.

M.T

(b)

18160.00
16022.00
14618.00
14084.00
12947.00
11744.00
11209.00
10407.00

Average rates ( for estimation only)

For 8mm to 20mm dia

M.T.

For above 20mm dia

M.T.

Providing & errecting slip form shuttering including dismentling after


completion, for constructing vertical structures such as, Jack Well,
Balancing Tank, Bridge Column, & for Horizontal structures in R.C.C.
The item includes, lifting arrangements, centering, form work, normal
dewatering, electrical arrangement with generater set and with all
equipments for slip form shuttering works with all material, fuel and
labour, operator. All risk & cost of labour, material & machinary work
lies with the provider itself. The rate is for various dia & depth and
various sizes of structures ..etc. complete.
Notes:If this item is adopted, necessesary deduction for regular shuttering
made in the RCC item shall be made.

sqm

15166.00
11120.00

Rate
( in Rs.)
2013-2014

Sr No

Item Description

Arrangement for lighting with cables till top height to be provided by


contractor.
Any accident or damage due to uncertain reasons will be the
responsibility of contractor.
No any Ideal charges for machinary & labour will be paid
Insurance for all type of machinary & workers will be at contracters
side.
All the material used for the slip form shuttering work should be of
good quality & durable
Notes for Estimations
1) All rates of reinforced cement concrete items from 1to 6 shall be
increased by 10% for each brace height above 1st brace for RCC
ESRs .
e.g. For a RCC ESR with 7 M staging and 1st Brace at 3.5 M above
Ground the concrete in columns above 1st brace concrete of ring
beam and bottom slab is entitled for 10% increase, concrete of
vertical walls, roof slab and roof beam, columns in containers are
entitled for 20% increase.
2) These rates are applicable for RCC well works also. These rates
shall be increased by 10% for every 5 M depth below initial 5M depth.
3) Rates for Items No. 7 & 8 shall be increased by 5% for each brace
height above 1st brace for RCC ESRs by 5% for every ring beam
below 1st ring beam for RCC wells.
4) Volumatric mix as per 1:1.5::3 shall be adopted with 56.5 Kg. of
cement for RCC 250 and 59.5 Kg. of cement for RCC 300 per load of
mixer of 1 bag capacity .
5) All rates of reinforced cement concrete items for 1to 6 shall be
increased by 2% for every floor height above ground floor for building
works.
6) Fusion bounded epoxy coating to proposed only in coastel area
with prior approval of Chief Engineer
7) For estimation purpose,average rates as per item no. 8 b shall be
considered wherever necessary.

Unit

Rate
( in Rs.)
2012-2013

Rate
( in Rs.)
2013-2014

Section - H- Miscellaneous Works


Sr No

Item Description

Unit

Providing and fixing G.I. pipe railing having 1.0 M height consisting 50
x 50 x 6 mm thick M. S. angles as verticals at 1.5 M c/c, and additional
posts at every corner with 3 rows of 25 mm dia G.I. pipes of medium
class variety as horizontal and painting 3 coats of oil paint over 1 coat
of anticorrosive paint of approved colour and shade including cost of
all labour, transporting bends to curved shape, etc. complete.

RMT

876.00

As above but with only 2 rows

RMT

686.00

i) conjusted area.

Litres

ii) Open Area

Litres

1.97
1.19

1A
2

a
b
c
d
e

Rate
( in Rs.)
2012-2013

Dismantling of ESRs of various capacities and heights using crane (10


MT capacity) and handing over M.S./ C.I./ G.I. pipes, valves, bends,
etc. to the Department However taking steel reinforcement by the
dismantling agency including removing dismantled materials from site
and disposing them at suitable place as directed, etc.complete.
Capacity of E.S.R. upto 2 lakh litres and stagging upto 12.00 M height

Capacity of ESR above 2 lakh ltrs. and staging upto 12 M hieght


i) Conjusted area

Litres

ii) Open Area

Litres

Providing and fixing M.S. gate 2.5 M wide for compound with 40 mm
dia M.S.black pipe medium class, approved grill work, RCC M - 150
side pillars of 25 cm x 40 cm x 2.5 M height, its foundation, finishing,
painting etc. complete.
Proividing and fixing Wicket gate 1.0 M wide for compound with 40
mm dia M.S.black pipe medium class, approved grill work, RCC M150 side pillars of 25 cm x 40 cm x 2.5 M height, its foundiaion,
finishing painting, etc. complete.
Taking Trial Bore (Core Bore Sampling) by Calyxe machine with
TCT/NX bits together undisturbed strata samples for investigation in
all types of strata soft soil, murum, hard murum with boulders, soft
rock hard rock & quartizite etc. The item includes all Hire & running
cost of Callyx Machine conveying all materials to site of work
excluding conveyance of callyx, machine and back sampling all over
burden strata in glass jar and core samples serially numbered at site
in a wooden Core Box, Samples to be taken at 1.0 m interval and
conveying to the place as directed by Engineer-in-charge, The
diameter of bore in overburden shall be 100 mm and of NX size
(50mm) in other strata. The item shall also include M.S. casing pipe of
2.5 mm thick plate in overburdern only and shall be 1.0 m above GL
with cap over it.

No.

1.54
1.07
26087.00

No.

15620.00

In Overburden (Soft soil, murum)

RMT

In Weathered rock with boulders

RMT

In Weathered rock / Soft rock

RMT

In Hard rock other than quartzite

RMT
RMT

In Hard rock quartzite

1156.00
4548.00
2324.00
3110.00
6760.00

Rate
( in Rs.)
2013-2014

Unit

Rate
( in Rs.)
2012-2013

Sr No

Item Description

Providing pressure grouting at a pressure of 0.56 kg./sqcm in required


row/zigzag fashion as specified at 1.5 M interval as per site conditions
to stop leakages through water retaining structures to the entire
satisfaction of the Engineer-in-charge including material compound,
hardening materials, compressor equipment including scaffolding
smooth finishing, etc. complete.

1
2
7

For masonry structure

Bag

For Concrete strcture

Bag
RMT

828.00
838.00
730.00

Litre

3.92

Sq.m

278.00

Drilling 40 mm dia holes in masonry or concrete structure with


providing and fixing 0.5 M long G. I. pipe line for perssure grouting
including all Material labour cost and machinery charges, etc.
complete.
Providing and casting ferrocrate water tank at site inculding all cost of
labour and material, etc, complete. upto 25,000 literes (for foundation
and providing and fixing taps, etc. shall be considered spearately).

Providing and applying two coat of Gamma coating or equivalent such


as Dr.Bake, Krishna conchem, Asian Paints, atul Limited Burger
paints epoxy primer 50 to 60 microns thick and covering two coats of
Gamma coatings or equivalent such as Dr.Bake, Krishna conchem,
Asian Paints, atul Limited Burger paints 30 microns thick each to new
M.S.Pipes and structural Steel or concrete surface including preparing
the surface by finishing by solvent degreasing and de-rusting by
applying chemical method and scaffolding if necessary etc. complete
as per manufacturers specifications.

10

Making cross connection to existing distribution main of any type


including excavation, breaking and removing exiting pipes, lowering,
laying of specials and pipes in their position, refilling, closing the water
supply in that area, dewatering and restarting the water supply, etc.
complete as directed by Engineer-in-charge for following diameters of
existing pipeline, irrespective of diameter of branch line (the number of
joints involved will be paid separately depending upon the nature of
joints and required pipes, valves and specials will be supplied free of
cost at stores).

80 mm

No

100 mm

No

125 mm

No

150 mm

No

200 mm

No

250 mm

No

300 mm

No

350 mm

No

400 mm

No

10

450 mm

No

11

500 mm

No

12

600 mm

No

13

700 mm

No

1676.00
1896.00
2104.00
2360.00
2510.00
2978.00
3620.00
4412.00
5143.00
5943.00
7338.00
12441.00
15413.00

Rate
( in Rs.)
2013-2014

Sr No

Item Description

Unit

Rate
( in Rs.)
2012-2013

19475.00
24902.00

14

750 mm

No

15

800 mm

No

16

900 mm

No

17

1000 mm

No

11

A
1

Note : Only 75% rate shall be payable till satisfactory hydraulic testing
is given.
Dismantling dead pipeline of M.S./R.C.C./ C.I./ P.S.C. and G.I./ A. C. /
P. V. C. / S. W. / H. D. P. E. pipe including cost of necessary
excavation and refilling of trenches, breaking the joints, lifting the
pipes and stacking to the place as directed by Engineer-in-charge with
all leads and lifts including cleaning the surface, etc. complete.
For M.S./R. C. C./ C.I./ P. S. C.
80 mm

RMT

100 mm

RMT

125 mm

RMT

150 mm

RMT

200 mm

RMT

250 mm

RMT

300 mm

RMT

350 mm

RMT

400 mm

RMT

10

450 mm

RMT

11

500 mm

RMT

12

600 mm

RMT

13

700 mm

RMT

14

750 mm

RMT

B
1

32768.00
45587.00

126.00
139.00
141.00
144.00
158.00
174.00
188.00
211.00
229.00
260.00
273.00
335.00
380.00
438.00

For G.I./AC/PVC/S. W. / H.D.P.E.


80 mm

RMT

100 mm

RMT

125 mm

RMT

150 mm

RMT

200 mm

RMT

250 mm

RMT

300 mm

RMT

350 mm

RMT

400 mm

RMT

10

450 mm

RMT

11

500 mm

RMT

12

600 mm

RMT

13

700 mm

RMT

14

750 mm

RMT

76.00
83.00
84.00
85.00
95.00
105.00
113.00
126.00
138.00
157.00
164.00
201.00
235.00
264.00

Rate
( in Rs.)
2013-2014

Sr No

Item Description

Unit

12

Providing and constructing two taps standpost as per type design wih
excavation 15 cm thick PCC 1:3:6 bedding 20 mm thick PCC 1:2:4
concrete for platform of 1.75 M dia. with side curb and bucket rest, 80
mm dia, heavy duty GI pipe central post duly filled therein with C. C.
1:2:4, 5 M long, 20 mm dia. medium G.I. pipe from point of tapping to
standpost additional 20 mm dia G.I. pipe fixed vertically upto 15 mm
dia self closing water taps, one brass ferrule etc. complete together
with all labour and material charges as per drawing and as directed by
Engineer-in-charge when good foundation is available. Rate
includes draining arrangemment by excavating open gutters.

No

6843.00

As above but when R.C.C. platform or Precast standpost issued free


of cost.
Providing and constructing two taps standpost as per type design wih
excavation 15cm thick boulder filling,15 cm thick PCC 1:3:6 bedding
20 mm thick PCC 1:2:4 concrete for platform of 1.75 M dia. with side
curb and bucket rest, 80 mm dia, heavy duty GI pipe central post duly
filled therein with C. C. 1:2:4, 5 M long, 20 mm dia. medium G.I. pipe
from point of tapping to standpost additional 20 mm dia G.I. pipe fixed
vertically upto 15 mm dia self closing water taps, one brass ferrule etc.
complete together with all labour and material charges as per drawing
and as directed by Engineer-in-charge when B.C.Soil is available.
Rate includes draining arrangemment by excavating open gutters.

No.

2566.00

No

7484.00

As above but when R.C.C. platform or Precast standpost issued free


of cost.

No

4633.00

14

RATES FOR ROAD AND RAILWAY CROSSING BY PUSH


THROUGH METHOD
Pushing of M.S. pipe of following dia for road crossing and
Railway crossing by push through method in all types of strata
by using hydraulic jack and drilling machine of required
diameter, below 3.0 m depth including lowering, laying, jointing
of M.S.casing pipe including cost of all labour, fuel and
material,required welding machinery,tripod, chain pulley
block,crane , blower etc.,transportation and Dewatering
etc.complete as directed by Engineer-in-charge but excluding
cost of M.S. Pipes.
200 mm dia to 499 mm dia M.S.pipe
500 mm dia to 1000 mm dia M.S.pipe

13

a
b

Rmt
Rmt

Rate
( in Rs.)
2012-2013

Rate
( in Rs.)
2013-2014

Section - I - ( XVII ) - TREATMENT PLANT ( W.T.P. & S.T.P. )


Sr No

Item Description

Unit

2
WATER TREATMENT PLANT ( W.T.P.)
Designing (aesthetically), providing and constructing high rate
Unconventional Water Treatment Plant i.e. Simplified Water
Treatment Plants consisting of Civil Works, including cost of
providing and applying Epoxy paint to inside surface of water
retaining structures in contact with Chlorine and providing antitermite treatment to entire structure below ground level,
Mechanical and Electrical components of variours sub-works
as given below : including necessary hydraulic testing,
structural testing and trial run for 3 months, etc. complete as
directed
by
Engineer-in-charge
.
( turn-key job ).

1) Aeration fountain
2) Inlet arrangements
3) Mixing channel with ventury flume and flow measuring
arrangement.
4) Inlet channel
5) Flocculator- Confirming to I.S. 7208-1974 ( Type-C )
with detention period of 30 minutes.
6) Tube Settlers " Designing, fabricating and construct
Tube Settlers with square or any other shaped tube like
Circular, Cheveron, Hexagonal etc. having proven
7) Rapid sand gravity filters.
8) Filter house
9) Chemical house
10) Alum tanks 2 Nos. with mixing, carrying and dosing
arrangement with piping.
11) Gravity feed gas chlorinator with 100% standby.
12) TCL solution tank with mixing, carrying and dosing
arrangement with piping.
13) Bye-pass arrangement
14) External and internal electrification
15) Laboratory equipments
16) Wash water tanks of capacity equal to 2% of designed
quantity of filtered water in a day ( + ) 10%
17) Wash water pumps with 100%standby
18) Pure water sump capacity equal to 1 hour pumping
capacity
19) Pure water pump house over the sump / by the side of
sump
20) Drainage arrangements
21) Alum store
22) Sanitary block with necessary water supply and drainage
arrangement and internal WBM roads

Rate
( in Rs.)
2012-2013
4

Rate
( in Rs.)
2013-2014
5

Sr No

Item Description

Unit

2
23) These rates are applicable for seismic zones 2, 3, and
4

Rate
( in Rs.)
2012-2013
4

24) Rates given below are inclusive of uplift pressure if any


and dewatering during the entire work
25) All RCC structures shall be constructed in M-300
26) Unconventional Treatement Plants less than 1 MLD
capacity shall not be constructed
Note:- Conditions from Sr.No. 1 to 26 shall form a part and
parcel of the tender and must be included in draft tender
papaers for the work of unconventional treatment plants.
Sr. No.

The rates are as under :Capicity in Mld.

Fixed cost for 1 MLD

Add for capacity above 1 MLD upto 2 MLD

Cost of 2MLD treatment plant

Add for capacity above 2MLD upto 5 MLD

cost of 5 MLD treatment plant

Add for capacity above 5MLD upto 10 MLD

cost of 10 MLD treatment plant

Designing (aesthetically), providing and constructing and


commissioning Conventional Water Treatment Plant
consisting of Civil Works, including cost of providing and
applying Epoxy paint to inside surface of water retaining
structures in contact with Chlorine and providing anti-termite
treatment to entire structure below ground level, Mechanical
and Electrical components of variours sub-works as given
below : including necessary hydraulic testing, structural
testing,equipment testing and trial run for 3 months, etc.
complete as directed by Engineer-in-charge . ( turn-key job ).

1) Aeration Fountain : Plan area not less than 0.625 square


metre per MLD
2) Ventury Flume : With necessary devices, consisting of
simple mechanical indicator ( Pedestal type guage)
3) Flash Mixer Rapid mixing device, detention time 60
sectonds to give velocity gradient 300 to 400 sec-1 vane mixer
type confirming to IS 7090 of 1985
4) Flocculator : Confirming to I.S. 7208 of 1974 ( Type-C)
with dentention period of 30 minutes
5) Clarifier : Horizontal flow circular tank, detention period 2-5
hours, overflow rate 30 cubic metre per squre metre per day (
tobe specificed), Weir loading not more than 300 cubic metre
per metre per day, with mechanical sludge scraper conforming
to I.S. 10313/1982

Unit

Rs. In
Lakhs

---

53.46

Per MLD

23.76

---

77.22

Per MLD

17.82

--Per MLD
---

130.68
14.26
201.98

Rate
( in Rs.)
2013-2014
5

Sr No

Item Description

Unit

2
6) Rapid Sand Filters and Filter House Filter designed for
filteration rate of 5,000 liters per squre metre per hour,
minimum 2 beds for plant upto 10MLD for larger plants as
specified , filters house with roof slab, pipe gallery and plat
form minimum 5.5 metre in width
a) Filter Sand : Effective size 0.45 to 0.70mm, uniformity
coefficient not more than 1.7, nor less than 1.3 , depth of water
over sand 0.75M , free board 50 cm , gravel 0.45 M depth,
sand and gravel confirming to I.S. 849 (I)-77 back wash by air
wash, Standard appurtenances ( to be specificed), rate of flow
controller, filler guage, sand expansion guage etc.

b) Wash Water Tank : Capacity to be specified and suitable


to supply water to wash 2 filter units at a time where the units
are 4 or more.
c) Wash Water Pumps : Capacity to fill water tank in 1 hours
with 100% standby
d) Air Blowers : Capable of delivering 600 LMP per square
metre of free air, of filter area at 0.4 Kg/square cm at the
underdrains
( 100% stand by)
7) Chemical House in Two Storeys
a) Ground floor to accommodate 7 days alum requirem ent
and sundry storage.
b) First floor to accommodate alum and lime tanks etc.
c) Solution tanks : Minimum 3 tanks ( One for preparation,
Second for dosing and third as standby), each tank capable of
giving 8 hours maximum dose without interruption, minimum
free board 0.30M trays for dissolving, level indica tor
mechanical agitation devices, solution feed and drain lines,
solution feed device( Constant head device strength of
solution upto 10% only) confirming to I.S.9222 part-I/1979.
8) Pure water Sump and Pump House
a) Capacity of sump : One hour of designed flow.
b) Pump House : Pump house of required size over the sump
or by the side
9) Store House : Suitable for alum storage of three months
requirement in mansoon with 10% extra capacity for other
sundry articles.
10) Vacuum feed type chlorinatros : make to be approved
by MJP
a) Confirming to I.S. 10533- A Part-II 1983
b) Rate of withdrawal
Temperature
Kg. of Chlorine discharge per day
Degree " C "

10
15
20
27 & above

Cylinders
45

67

Tonners

6.35

9.50

110

10.75
14.50
18.70

16.10
21.24
28.12

130
254
315

Rate
( in Rs.)
2012-2013
4

Rate
( in Rs.)
2013-2014
5

Sr No

Item Description

Unit

2
c) Chlorinator equipment and container room : to confirm
to I.S. 10553 Part-I 1983
d) 100% standby shall be provided
11) By pass arrangement - C.I. Or M.S. pipes
12) Drainage arrangement : RCC pipes upto plot boundry.

13) Electrical installation : Both internal and external


including entire plant area.
14) Laboratory equipment : As per requirement ( to be
specified during tendering)
15) Sanitary blocks : Carpet area-15 square metre minimum
upto 25 Mld. And 25 square metre above 25 Mld.
16) Adminstrative block and internal road.
To accommodate office room, chlorine room, laboratory room,
panel board room, blower room etc. andWBM road to connect
all units from main gate of plot.
17) Rates given blow are inclusive of uplift pressure if any
and dewatering during entire work.
18) These rates are applicable for seismic zones- 2,3 and
4.
19) All RCC strucrure shall be constructed in M.300
NOTE:Condition from Sr. No.1 to 19 shall form a part and
parcel of the tender and must be incorporated in draft tender
papers of conventional treatment plants Rate for Conventional
Treatment Plants ( Proposed)
Sr. No.
Capicity in Mld.
1
2
3
4
5
6
7
8
9
10
11

Upto 5 MLD
Cost of 5 MLD Treatment Plant
Add for capacity above 5 MLD upto 10 MLD
Cost of 10 MLD Treatment Plant
Add for capacity above 10 MLD upto 20 MLD
Cost of 20 MLD Treatment Plant
Add for capacity above 20 MLD upto 50 MLD
Cost of 50 MLD Treatment Plant
Add for capacity above 50 MLD upto 100 MLD
Cost of 100 MLD Treatment Plant
Add for capacity above 100 MLD
Designing (aesthetically), providing, fabricating, Package
Water Treatment Plant. At the shop, transporting to site,
installing, testing and commissioning at the site, giving
necessary one months free test and trial run with guarantee
for one year, etc. complete.
Prefabricated Package Water Treament Plant comprising
following
1. Rapid mixing Channel in M.s.Sheets and M.S. baffle.
2. Flocculator not less than 10 minutes detention, in M.S.
prefabricated box, flocculation being achived either by glass
pebbles of graded size or PVC tetrapod or equivalvent
arrangement to ensure good floc formation.

Unit
MLD
-MLD
-MLD
-MLD
-MLD
-MLD

Rate
( in Rs.)
2012-2013
4

Rs. In
Lakhs
33.26
166.30
23.76
285.10
15.44
439.50
14.26
867.30
11.88
1461.30
9.50

Rate
( in Rs.)
2013-2014
5

Sr No

Item Description

Unit

2
3. Plate or tube settlers of not less than 30 minutes
detention, in M.S. prefabricated box, plates/ tubes mounted in
the settler basin with inclination of not less than 60 degree to
horizontal
4. Rapid sand gravity filter in M.S. prefabricated box with
filter sand not less than 500mm thick, supported on false
floor below with polypropylene nozzles spaced at not more
than 500mm centres in either direction.
5.Backwashing, inlet facilities
inlet facilities shall be
provided.
5.1 Air Blowers : Capacity of delivering 600 LMP per sq.mtr.
Of free air of filter area 0.4 Kg./Cm2 at under drain ( 100%
5.2 Wash) water tank of capacity equal to 2 % of designed

quantity of filtered water in a day (+) 10%.


5.3 Wash water pumps with 100% stand bye ( Minimum 3Hp
with all accessories )
6 Laboratory equipments
6.1 External & internal Electrification.
6.2 TCL solution tank with mixing , carrying & dosing
arrangement with piping.
6.3 Gravity feed gas chlorinator with 100 % standbye.
6.4 Alum storage unit.
6.5 Drainage arrangement.
6.6 Office and Lab. Space with necessary water supply &
drainage arrangement and internal roads.
6.7 Sump well and pump house
6.8 Wire fencing with gate for W.T.P. Premises.
7. All civil works for foundation, consisting of raised RCC
platform above G.L. or walls in B.B. Masonary or UCR
masonary shall be provided as per needs at site.
8. Bye pass in the form of pipes or M.S. channels included
in the desing, effecting bye pass or such new tank and filter
individually or both ( Limit upto 5.0 M from W.T.P. face)
9. The entire M.S. Fabricated tank provided with FRP
lining ( 5 mm thick) to inside face in contact with water epoxy
painting-two coats with one coat of primer on outside. The
thickness of plates cmployed shall be not less than 6mm
10. Alum dosing and mixing arrangement to be provided in
twin tanks, each of 8 hours capacity, capable of importing
dose of 20 ppm with 5% solution. The alum tanks provided
with a dose in steps 5 ppm and entire unit mounted on the
top of flocculator/ settler box, in the form of prefabricated
structure., with access platform and ladder. Alum boxes with
FRP lining ( 5mm thick) inside and epoxy paint two coats with
one coat of primer on outside.
11. Both flocculator and settling basins provided with
hopper bottom with slope not less than 45 degrees to the
horizontal Drain pipes and valves provided to both flocculator
and settling basin.
12. Flow rating to confirm following parameters:

Rate
( in Rs.)
2012-2013
4

Rate
( in Rs.)
2013-2014
5

Sr No

Item Description

Unit

2
a) Velocities in channels not to exceed 0.6 M/Second.
b) Velocities in filter outlet pipes and valves not to excess
1 M/Seconds
c) Velocities interconnecting pipe and control not to exceed
1 M/ Seconds.

d) Backwash with air : Not required


e) Backwash with water : Not less than 0.6 Cu.M/ Sq.m. of
filter bed area in filter box.
13. Free board for all units not less than 300mm
14. Rates as above include all taxes, octroi and duties which
would be specific to the site location.
Sr. No.
Capicity in Mld.
1
2
3
4
5
6

4,A

Sr. No.

1
2
3
4
5
6
7
8

21 Cu.m/Hr. (0.5 MLD)


34 Cu.m/Hr. (0.80 MLD)
42 Cu.m/Hr. (1.00 MLD)
63 Cu.m/Hr. (1.50 MLD)
83 Cu.m/Hr. (2.00 MLD)
125 Cu.m/Hr. (3.00 MLD)
Note:- Depending upon the capacity required for the scheme,
one of the above capacity should be choiced.

Each
Each
Each
Each
Each
Each

Rate
( in Rs.)
2012-2013
4

Rs. In
Lakhs
27.44
33.69
37.78
47.40
56.14
72.35

SEWEAGE TREATMENT PLANT ( STP)


Designing (aesthetically), providing, and constructing and
giving satisfactory trials of modernised Sewage Treatment
Plant consisting of receiving chamber, screen chamber, grit
chamber, measuring flume, distribution chamber with primary
and secondary treatment, etc. as detailed below,
administration block of suitable size including allied units for
waste disposal with all civil and mechanical works involved,
etc. complete turn key job.
Primary treatment - with extended sludge drying beds
(oxidation ponds)
Capicity of plant
Unit

Upto 10 MLD
Cost of 10 MLD plant
Add for capacity above 10 MLD upto 20 MLD
Cost of 20 MLD plant
Add for capacity above 20 MLD upto 50 MLD
Cost of 50 MLD plant
Add for capacity above 50 MLD upto 100 MLD
Cost of 100 MLD plant

MLD
-MLD
-MLD
-MLD
--

Rs. In
Lakhs
47.52
475.20
41.58
891.00
35.64
1960.20
29.70
3445.20

Rate
( in Rs.)
2013-2014
5

Sr No

Item Description

Unit

2
Designing (aesthetically), providing, and constructing
,hydarulic testing ,commissioning and giving satisfactory trials
of modernised Sewage Treatment Plant consisting of inlet
chamber, screen
chamber ,Detritus Tanks, Partial
flume, primary settling tanks, Aeration tanks, Secondary tanks,
Sludge sump and pump house, Sludge thickner, Primery
digester, SST sump and pump house, chlorine contact tank
Chlorinators, Chlorinator room, sump cum blending tank
(SCBT) PST sludge sump cum blending tank, Pump House
Sludge Centrifuge gas holder, necessary piping work with
required valves , gates, drains, pathways, Administrative
Building cum Laboratory, Laboratory equipments, tools and
plants, Spare parts etc. complete as tunkey job with all
involved civil electrical and mechanical works inclusive of
following items units as per detailed specification for civil,
electrical and mechanical components with all duties and
taxes etc complete.

4,B

Inlet Chamber:
Designing, providing and constructing RCC (m:300) Inlet
chamber designed for the peak flow 2 DWF including
necessary excavation in all types strata including walkway
around the periphery. Each compartment will have phosper
bronze, steel gate with extension rod, head stock, operating
wheel, G.I. pipe railing etc. The work includes providing and
making necessary arrangements to connect the flow to screen
chamber by approach channel as directed and as per
specifications.
Screen Chambers:
Designing, Providing and constructing and testing
commissioning screen chamber, designed for average 1 DWF
and maximum 2 DWF in RCC ( M-300), including inlet pipe/
Channel from inlet chamber outlet pipe/Channel to detritus
tank, free board of 0.50 M minimum RCC walkway 1.2 M wide
with G.I. pipe railing. RCC stair case of 1.2m width from G.L.
to screen chamber.
Detritus Tank:
Designing , Providing and constructing continuously grit
removal type of Detritus Tank, mechanically operated inRCC (
M 300) capable of removing 100% 0.20mm size particle and
above, having specific gravity 2.30 designed for one peak 2
DWF with suitable arrangement of separation of grit from
putrescible solids including providing and making necessary
arrangement of JB-1 inlet and outlet channels of required
sizes as may be required to connect the flow to parshall flume
etc. complete. including hydrualic testing for water tightness of
the structure having minimum free board of 0.30m washout
arranement to grit chamber and platform 1.20m wide RCC
walkway with G.I. pipe hand railing shal be provided. A pit for
collecting grit conveyed by conveyor shall be provided. It
should be suitable to handle the grit for carting. All
arrangements shall be as per detailed specifications and as
directed
Parshall Flume.

Rate
( in Rs.)
2012-2013
4

Rate
( in Rs.)
2013-2014
5

Sr No

Item Description

Unit

2
Designing, Providing and constructing Parshall, Flume
Channel in RCC (M300) for measuring quantity of sewage
received at the treatment works, max flow of 2 DWF and
minimum flow of 1/2 DWF including providing and making
necessary arrangement of approach channel as may be
required to connect the flow having minimum velocity of 0.3 m
per second to Distrubution Box ( DB-1) The unit shall be
provided with walkway & RCC staircase having width of 1.20m
each etc. complete, including hydraulic testing for water
tightness of the civil structure having free board of 0.6 m
including electrically operated, flow indicating and flow
integrating devices having standby of float operated ROF
meter. All arrangement as per specifications.

Primary Settling Tanks With Equipments:


Designing, Providing, constructing and hydrulic testing in RCC
(M-300) water tight Primary Settling Tanks of 1 DWF capacity
with feed chamber sludge and effluent chamber, base
adequately supported providing 1.20 m wide clear peripherial
and approach walkway inter connecting C.I. double flanged
pipes from feed chamber of the clarifier distribution well
grouting wherever necesary, including foundation etc. as per
specification water depth at outer side shall be minimum 3.0
meter weir loading shall not be greater than 125cum DMF for
average flow Bottom slope shall be 1:12

The floor of clarifier shall have 40mm thick ( min) screed


course of cement grout of mix C.M.1:2 Detention period shall
be 2.25 hrs. dispersion box and stiffenedweir plate made of
mild steel plate not less than 8mm thick, anticorrosive epoxy
paint on both faces shall be provided Minimum free board of
0.50 m be provided it includes inlet pipe from distribution
chamber, central shaft inlet baffle outlet chamber Scum
remover, skimming devices scum chamber, connecting
channel from PST outlet chamber, to db-2 as per detailed
specifications.
Aeration Tank (AT)

Rate
( in Rs.)
2012-2013
4

Rate
( in Rs.)
2013-2014
5

Sr No

Item Description

Unit

2
Desiging, Providing and constructing in RCC mix ( M-300)
Aeration Tank in compartments to handle combined flow of 1
DWF incoming flow and recirculation flow including
construction of inlet, outlet and distribution chamber DB-3 and
providing 1.20 M wide clear peripherial and approach
walkways, expansion joints wherever necessary, including
foundation etc. as per specification. Peak factor shall be 2,
F/M ration shall be 0.40 low speed aerator speed between 20
to 100 RPM recirculation flow @ 50% and free board 0.60m,
Depth ( SWD) 3.50m ,minimum D.O. level at A.T. 2 Mg/Lit
MLVSS concentration shall be 2500mg/Lit and MLVSS
concentration shall bw 2000 Mg/Lit, HRT shall be 4 to 6 hours
and STR 6-8 days. It should have compartents for washing
oxygen transfer capacity of mechanical aerator shall not be
less than 1.5 Kg/KWH, BOD of effluent 20mg/lit with input to
aerator 0.15, to 0.30 Kwh/ 1000 cum of Aeration tank. All
related works shall be as per detailed specification.

Secondary Settling Tanks with equipments


Desiging,Providing and constructing in RCC )M:300) water
tight Secondary settling tank having detention period 2 hours
and SWD shall be 4.20 meter. The effluent BOD and SS from
the secondary clarrifier shall not be more then 20 Mg/lit and
30mg/lit. respectively. It should be hydraulically tested, bottom
floor slope of 1:12 and fee board of 0.60m minimum
Dispersion box shall be made of Mild Steel plate not lesss
then 8mm thgick with anticorrosive epoxy paint from both
faces and well stiffened. The sewage admitted at the centre
flowing upward and outwards towards periphery be slowly and
continuously collected towards a convenient discharge point
near centre by a rotating wheel arm.
The Clarfier will be complete.with end drive half rotating bridge
structural steel rake, over flow weir, walkway diffuser, over
load alarms, having push bottoms, starters for the clarifier,
walkway and the suitable sludge withdrawing arrangement
with flush valve capable of withdrawing moisture content not
more than 97% to 98% sloping floor shall have 40mm
thickness (Minimum), screed course of cement grout of mix 1
cement :2 sand, rotating sludge scrapper mechanism filled
with squeezes including providing and making necessary
arrangements to connect the flow to outlet chamber (DB-4)
then the gravity main for final diaposal and as per detailed
specification and obligatory provision. All other arrangements
shall be as per detailed specification.

Rate
( in Rs.)
2012-2013
4

Rate
( in Rs.)
2013-2014
5

Sr No

Item Description

Unit

2
Sludge Thickner with equipments:
Designing providing and constructing water tight of Sludge
Thickner (Gravity type) including foundation inRCC (M-300)
with inlet and outlet chamber, influent well, inlet and outlet
pipes, with sludge pit and lsudge removal arrangement,
grouting wherever necessary with walkway all around of 1.20m
width, G.I. pipe railing interconnecting CI pipes all complete as
per specification Detention time 24 hours. SWD shall be 4.25
metre with necessary fixed bridge scraper arrangment as per
detailed specification and necessary inlet and outlet
arrangement. All other arrangement as per detailed
specification.
Primary Digestor with mixer equipment( Fixed Cover)

Designing, Providing and constructing unit of water tight and


gas tight Primary Digester suitable for 1 DWF plant and
complete with pipe gallery, building staircase for access from
dome of digester into inside staircase, walkways at springing
levels etc. walls and base slab being in RCC M-300 domes in
structural concrete including providing burners and civil works
for gas collection, grouting wherever necessary etc. complete
as per specification. It should be designed from min 9o C and
max. 45o C and minimum detention time of 30 days, water
depth shall not be more then 8.5 m free board shall be 0.6m
with inlet and outlet arrangement of C.I. flanged pipes
including giving hydraulic testing and air tightness testing. The
item includes works for colleting Gas and Gas burner as per
specification.
Secondary Digester with equipment( Fixed cover)
Designing ,Providing and constructing including foundation
unit of watertight and gastight Secondary Digester to deal with
I DWF complete with pipe gallery, building, staircase for
access from dome of digester into inside, staircase to walways
at springing levels etc. Walls and base slab and domes being
in RCC M-300, providing arrangement for digested sludge
from digesters to centrifuge , providing burners and civil works
for gas collection grouting whrever necessary etc.complete. as
per specification and obligatory provision All other
arrangements as per detailed specifications.
S.S.T.Sump and Pump House with recirculation Pumps
and Sludge Pumps to Digester:
Designing,Providing and constructing sump & Pump house of
requisite capacity with ceiling height not less than 6 M Sludge
stream for recirculation to aeration tank and excess sludge to
SCBT including C.I. Piping to carry this flow to sump as per
detailed specification and as direcgted by Enginer-in-charge.
Chlorine Contact Tank:

Rate
( in Rs.)
2012-2013
4

Rate
( in Rs.)
2013-2014
5

Sr No

Item Description

Unit

2
Designing, Providing and Constructing Chlorine Contract
chamber of adequate capacity to deal with 1 DWF. Average
flow. The chlorine contact tank should be of 30 minutes
capacity during average flow to achieve 99.99% coliform
reduction. Chlorine dose shall be maintained as per standard
provision including provisions including designing, providing
and constructing water supply arrangment for chlorination,
including providing dewatering and bypass arrangments
joiting to final efluent main and outlet weir etc. complete The
effluent quality should match with the standard laid donw my
Maharashtra Water Pollution Control Board and as per the
obligatory provision and detailed specification and as directed
by Engineer-incharge.

Chlorinator and chlorinator Room/ Tonner Room


Desiginging, Providing and constructing chlorinators vaccum
type 2 Nos. each having capacity of 10 Kg/Hr. as per
obligatory provision and detailed specification with necessary
provision of chlorinator room having floor area not less than 30
Sq.m including automatic residual chlorine controller with
actuator and residual chlorine analyser including cost of
chlorine cylinder, piping valves measuring and controlling
equipments, safety devices, lifting equipments, etc. complete.
as per I.S.-10553
( Part/II) 1982 The tonner room
should have 3 MT capacity crane for loading and unloading
facility. Tonner storage should distrincitly isolated and should
be for minimum 10 Tonners space and arrangement as per
gas laws 1981 and factory act shall be provided, and all other
matching amenities be provided, 5 MT gantry shall be
provided for full length of Tonner room at 6 m height from floor
level, with/ outlet chamber and treated effluet outlet channel
etc. complete. as per detailed specification.
Sump Cum Blending Tank ( SCBT)
Designing providing and constructing sump cum blending tank
of appropiate size and detention time with free board of 0.60 m
The slope of floor 1:4 with suction pit at the cnetre as per
detailed specification and obligatory requirements
P.S.T. Sump cum Blending Tank, Pump House with
reciuculation pumps
Desiginig, providing and constructing pump house of
appropriate size with pumps ,ceiling height minimum 6m over
the circular sump for discharging the sludge to thickner and
recycling of flow for blending, with C.I. Piping etc. complete.
As per detailed specification

Rate
( in Rs.)
2012-2013
4

Rate
( in Rs.)
2013-2014
5

Sr No

Item Description

Unit

2
Sludge Centrifuge Room with Centrifuges:Designing, providing and constructing and installing including
foundation etc. Sludge Centrifuge to handle the sludge flow of
one day in one hour per unit with sludge dewatering unit drain
etc. complete as per specification. Sludge centrigure with all
necessary arrangement as per detailed specifications
mentioned in Volume-II and Volume-III of tender and
obligatory provisions, be provided with satisfactory functioning.

Gas Hoder:
Designing, Providing and constructing gas holder having gas
collection system gas flow meter and gas burner with floating
dome arrangment and storage time 6 hrs. to be constructed in
M-300 having appropriate diameter as per detailed
specification and obligatory provisions. The flating dome shall
be of 8mm thick M.S. plate minimum and shall be provided
with two coats of anticorrosive epoxy coating from both faces.

Outfall Sewer :
Designing providing and constructing approprate Outfall
Sewer of RCC NP-2 pipe to discharge treated effluent,
untreated effluent from outlet chamber ( after secondary
clarifier) to the local nalla at a point shown on the drawing
including necessary chambers for inspection/ cleaning
including necessary excavtion dewatering refilling, concrete
encasing/ bedding ,concrete steps to reach the nalla bed level.
pitching and energy dissipation chamber in the nalla portion
etc. complete upto 50 m length RCC NP-2 pipe line and
inclding all above items
Piping work in C.I.L.A. class including Sluice valves,
Reflux valves M.S.Gate.
Providing laying and jointing pipe other than those already
included in the above items for interconnection by-pass drains
etc. ofall units including adequate numbers of manhole
chambers. The item includes excavation, refilling and
hydraulic testing of pipes, valves, gates, accessories and cost
of jointing material . The item includes required channels with
gates for interconnection of units by pass drains etc. for all
units and as directed etc. complete. as per detailed
specification.

Rate
( in Rs.)
2012-2013
4

Rate
( in Rs.)
2013-2014
5

Sr No

Item Description

Unit

2
Administrative Building Cum Laboratory ( G+ 1)
Designing, providing and constructing Administrative
Building office cum Laboratory including stores. This shall be a
building having appropriate Carpet area at ground floor and at
first floor complete as per specifications including necessary
excavation , foundation in RCC M-200 framed structure, B.B.
Masonary ( II-Class inC.M. 1:6) 20mm cement plaster in C.M.
1:3, inside and outside painting ,Alluminium door and window
with glass pannels mosaic tile flooring and skirting and all
other allied items, fixtures fastening electrification arrangement
water supply arrangement etc. complete. The building will
have laboratory on upper flor of administrative building and
should be so centralised that it should not be attached with
any units but should have complete control of every unit as per
Laboratory Equipment, beautification, telephone and intercom
arrangement and wireless system etc. complete.

Sr. No.
1
2
3
4
5
6
7
8
4D

B) Primary and secondary treatment - with digesters , sludge


drying beds etc. complete.
Capicity of plant
Upto 10 MLD
Cost of 10 MLD plant
Add for capacity above 10 MLD upto 20 MLD
Cost of 20 MLD plant
Add for capacity above 20 MLD upto 50 MLD
Cost of 50 MLD plant
Add for capacity above 50 MLD upto 100 MLD
Cost of 100 MLD plant
Designing, Providing, Constructing, Erecting, Testing and
successful Commissioning of various units with trial runs of 3
months of Sewage Treatment Plant of various Capacities
based on IMPROVED BIO TOWER TREATMENT OF WASTE
WATER including receiving / inlet chamber, fine screen
chamber, grit chamber, distribution chamber, Biotower,
aeration tank, secondary settling tank, excess sludge pump,
air blowers, air diffusers, chlorine contact tank, Sludge
Thickener, centrifuge unit with sludge feed pumps,
Polyelectrolyte Jelly tank with mixer and dosing pump etc. with
all ancillary works including Administrative building, internal
road, land developement,drainage line laboratory equipment,
furniture etc. including mechanical, electrical works,
instrumentation PLC/SCADA automation etc. complete. to
achieve BOD < 10 ppm, COD < 50 ppm, TSS < 10 ppm, pH
Between 7 to 8.5 , Oil & Grease < 10 ppm recyclable quality of
water for industrial/agricultural purpose.
UNITS INCLUDED

INLET CHAMBER

Unit
MLD
-MLD
-MLD
-MLD
--

Rate
( in Rs.)
2012-2013
4

Rs. In lakhs
57.02
570.20
49.90
1069.20
42.77
2352.30
35.64
4134.30

Rate
( in Rs.)
2013-2014
5

Sr No

Item Description

Unit

2
Designing, providing and constructing commissioning and
hydraulic testing Inlet chamber for the peak flow of 2 DWF
including necessary excavation in all types of strata including
walkway1.2 m wide all round the periphery.
CIVIL ITEM- All component of inlet chamber shall in RCC M30
only
MECHANICAL ITEM - CI Gates with phosphor bronze
sealing face /strips with extension rod, head stock, operating
wheels. Pipe railing shall be in GI pipe with MS angle post
.etc.
The work includes providing and making
necessary arrangements to connect the flow to screen
chamber by approach channel as directed and as per
specifications.
SCREEN CHAMBER
Designing, providing, constructing, testing and commissioning
of screen chamber, designed for average 1 DWF and
maximum peak flow of 2 DWF. This unit shall be provided free
board of 0.5 m minimum, RCC walkway 1.2 m wide with GI
pipe railing, RCC stair case of 1.0 m width from GL to screen
chamber.
CIVIL ITEM All component shall be in RCC M-30 only,
MECHANICAL ITEM - All screens provided
(Mechanical/Manual) with MOC SS 304 with belt conveyor
mechanism , Piping of CI/DI/MS .

DETRITUS TANK
Designing, providing ,constructing, testing and commissioning
continuous grit removal type Detritus tank, mechanically
operated capable of removing 100% of 0.2 mm size particle
and above, having specific gravity 2.30 designed for one peak
flow of 2 DWF with suitable arrangement of separation of grit
from putrescible solids. Inlet and outlet channels of required
sizes as may be required to connect the flow to connecting
unit etc. Complete including hydraulic testing for water
tightness of structure having minimum FB of 0.3 m, wash out
arrangement to grit chamber and platform 1.2 m wide RCC
walkway with GI wide RCC walkway with GI pipe handling
shall be provided. Item to include closed Chute of GI sheet to
convey the grit to the hand cart placed below it and two hand
carts . All arrangements shall be as detailed specifications
and as directed.
CIVIL ITEM :- All component shall be in RCC M30 only.
MECHANICAL ITEM:- All component of grit mechanism
shall of MSEP and approved make with adequate HP
electrical motor to run the mechanism .
BIOTOWER

Rate
( in Rs.)
2012-2013
4

Rate
( in Rs.)
2013-2014
5

Sr No

Item Description

Unit

2
Designing, providing , constructing, testing and commissioning
in RCC (M-30), BIOTOWER according to drawings' received
from technology provider , for biological removal of BOD in
compartments to handle combine flow of 2 DWF and to be
checked for peak flow incoming flow including construction of
Tower with Media , rotating arm with sprayers and providing
1.2 m wide clear approach walkways, wherever necessary,
including foundations etc. as per specifications.,including PVC
Media , sprinkler system with rotating arm / equipment and FB
0.5 m and SWD as required.
Peak factor shall be 2
Biotower recycle sump of adequate capacity including
pumpsnshall be provided to maintain the wetting rate of biotower
to lean flow conditions
CIVIL ITEM :- All component shall be in RCC M30 only.
MECHANICAL ITEM:- PVC Media , Sprinkler system in MS
pipes epoxy painted, recirculation system &required piping of
CI /MS epoxy painted etc.

4A

MIXING CHAMBER
Designing, providing , constructing, testing and commissioning
in RCC (M-30), MIXING CHAMBER to handle flow of 1 DWF
and recirculation flow including construction of baffel walls ,
foundations etc. as per specifications., to ensure complete
mixing of raw sewage received from Bio-tower and
recirculation flow from SST , capacity of mixing chamber shall
be
as
per
designer
requirement.
CIVIL ITEM :- All component shall be in RCC M30 only.

AERATION TANK (AT)


Designing, Providing , constructing, testing and commissioning
Aeration Tank in compartments to handle combined flow of 1
DWF incoming flow and recirculation flow including
construction of inlet, outlet and distribution chamber and
providing 1.20 M wide clear peripheral & approach walkways
with GI Hand railing , expansion joints wherever necessary,
including foundation etc. as per specification. Peak factor shall
be 2, F/M ration shall be 0.30 to 0.40, fine bubble diffused
aeration , recirculation flow @ 50% and free board 0.60m,
Depth ( SWD) 3.50m ,minimum D.O. level in the tank to be
maintained at 2 Mg/Lit, MLSS concentration shall be
2500mg/Lit and MLVSS concentration shall be 2000 mg/lit.
HRT shall be 4 to 6 hours and SRT 6-8 days. It should have
compartment for washing. The process shall be automated
with DO sensors in the tank . providing data to PLC which in
turn shall operate blowers. . All related works shall be as per
detailed specification.
epoxy
painted

Rate
( in Rs.)
2012-2013
4

Rate
( in Rs.)
2013-2014
5

Sr No

Item Description

Unit

2
CIVIL ITEM :- All component shall be in RCC M30 only
Suitable Air blower room shall be provided near aeration tank
with
acoustic
arrangement.
MECHANICAL ITEM :- Diffusers of EPDM material , air
blowers with VFD, air piping of MS. epoxy lined and out
coated up to water level and PVC inside water & accessories
shall be provided as per detailed specification.

Instrumentation and Automation


DO sensors to each compartment with necessary cable ,
PLC of adequate capacity & control panel for PLC & control
there from using required cables etc. The PLC programming
shall be done with approved logic. to save electric Power.
Secondary Settling Tanks with equipments
Designing, Providing and constructing in (RCC M: 30) water
tight Secondary settling tank having detention period 2 to 3.5
hours and SWD shall be 3 to 4 meter. The effluent BOD and
SS from the secondary clarifier shall not be more than 10
Mg/lit and 10mg/lit. respectively. It should be hydraulically
tested, bottom floor slope of 1:12 and fee board of 0.60 m
minimum Dispersion box shall be made of Mild Steel plate not
less than 8mm thick with anticorrosive epoxy paint from both
faces and well stiffened. The sewage admitted at the centre
flowing upward and outwards towards periphery be slowly and
continuously collected towards a convenient discharge point
near centre by a rotating mechanism.
The Clarifier will be complete with central driven /peripheral
driven half rotating bridge structural steel rake, over flow weir,
walkway , diffuser, over load alarms, having push bottoms,
starters for the clarifier, walkway of 1.2 m wide GI railing and
the suitable sludge withdrawing arrangement with flush valve
capable of withdrawing sludge with moisture content not more
than 97% to 98% sloping floor shall have 40mm thickness
(Minimum), screed course of cement grout of mix 1 cement :2
sand, Rotating sludge scrapper mechanism filled with
squeezers including providing and making necessary
arrangements to connect the flow to outlet chamber & then to
the gravity main for final disposal and as per detailed
specification and obligatory provision. All other arrangements
shall be as per detailed specification. CIVIL ITEM - All
component shall be in RCC M-30 only. MECHANICAL ITEM Clarifier bridge component shall be of MS epoxy painted
along with adequate capacity of drive mechanism , The
component coming in contact of waste water shall be
MSEP/SS as per detailed specification.

Piping for treated effluent shall be of CI/DI/MSEP for sludge


shall be CI/HDPE/MS.
Chlorine Contact Tank

Rate
( in Rs.)
2012-2013
4

Rate
( in Rs.)
2013-2014
5

Sr No

Item Description

Unit

2
Designing, providing and constructing chlorine contact
chamber of adequate capacity to deal with 1 DWF average
flow. The chlorine contact tank should be 30 min capacity,
during average flow to achieve colliform reduction to the level
of MPN 1000/100ml. Chlorine dose shall be maintained as
per standard provisions, including designing, providing and
constructing water supply provision for chlorination including
providing dewatering pump and byepass arrangement,
dechlorination arrangement jointing to final effluent mains and
outlet weir, etc. complete. the effluent quality should match
with the standards laid down by Maharashtra pollution control
board and as per obligatory provision and as detailed
specification and as directed by Engineer-in-charge.

Chlorinator and Chlorinator Room / Toner Room


Designing, providing and constructing chlorinators vacuum
type 2nos or more with auto switchover facility and having
capacity of dosing of adequate chlorine to ensure count of
maximum MPN 1000/100ml coli form reduction as per
obligatory provisions and detailed specifications with
necessary provision including chlorinator room of adequate
size. The chlorinator equipment shall include chlorine
cylinders / toner piping, valves, measuring and controlling
equipments, safety devices, lifting equipments, etc. complete
as per IS - 10553 (Part II) 1982. The toner room should have
minimum 3 MT capacity Hoist for loading and unloading
facility. Toner storage should be distinctly isolated and should
be for minimum storage space as directed in the design
specification and as per gas laws 1981 and factory act shall be
provided. All other matching amenities shall be provided,
Minimum 3 MT gantry rail shall be provided for full length of
toner room at 6 m height from level of toner room, with outlet
chamber and treated effepoxy painted etc.

Sludge recirculation pump House


Designing, providing, constructing, Commissioning and testing
of pump house to accomodate recirculation sludge pumps of
apprpriate size , with pumps , ceiling height minimum 4 m over
sump for discharging sludge from SST to Aeration Tank
using CI pipe complete as per detailed specification.
CIVIL ITEM - All component shall be in RCC M-30only,
MECHANICAL ITEM - Sludge pumps shall be minimum1
Nosincluding 100 % standby , Piping and valves shall be of
CI . Suitable lifting arrangement shall be provided. Sludge
recirculation pumps shall be of adequate capacity for
maintaining the MLVSS in aeration tank with 100 % standby .
Sludge recycle piping shall be CI.

10

Sludge Thickener

Rate
( in Rs.)
2012-2013
4

Rate
( in Rs.)
2013-2014
5

Sr No

Item Description

Unit

2
Designing, providing ,constructing, commissioning and testing
of sludge thickener -gravity type with inlet & Outlet pipes ,
Central feed well , sludge pit & sludge removal arrangement ,
with necessary walkway all around of 1.20m wide with GI
railing inter connecting piping all complete with necessary
fixed bridge scraper arrangement as per detailed specification
.CIVIL ITEM - All component shall be in RCC M-30only,
MECHANICAL ITEM - fixed bridge shall be in MS and All
component in contact water shall be MSEP/CI.Piping shall be
of CI.
CENTRFUGE UNIT
Designing, providing, constructing , installing ,commissioning
and testing centrifuge unit to handle the sludge flow of 1 day
in 20 hours per unit with sludge dewatering unit drain etc.
complete as per specification. Sludge feed pumps with the
necessary arrangement, as per detailed specification
mentioned in tender and obligatory provisions to be provided
with satisfactory functioning. CIVIL ITEM - All component
shall be in RCC M-30only, MECHANICAL ITEM -all
mechanical items shall be provided as per specification
confirming to Relevant IS, and Piping shall be of CI/HDPE.
Chute in GI , Decanted water piping in PVC .

11

12

Outfall Sewer
Designing, providing and constructing appropriate outfall
sewer of RCC NP2 pipe, to discharge treated effluent from
outlet chamber after chlorination tank to the local Nallah at the
point shown on the drawing including necessary chamber for
inspection and cleaning including necessary excavation,
dewatering, refilling concrete encasing / bedding concrete
steps to reach the nallah bed level, pitching and energy
dissipation chamber in nallah portion etc. complete up to 50 m
length RCC NP2 pipe line and including all above items.

13

Piping work in CI-LA Class including Sluice Valves, Reflux


Valves, MS Gates
Providing laying and jointing pipes other than those already
included in the above items for interconnection by - pass
arrangements etc. of all units including adequate numbers of
manhole chambers. The item includes excavations, refilling
and hydraulic testing of pipes, valves, gates, accessories and
cost of jointing materials. The items includes required
channels with gates for interconnection of units by pass
arrangements etc. for all units as directed etc. complete as
per detailed specifications.

14

Administrative Building cum Laboratory (G +1)

Rate
( in Rs.)
2012-2013
4

Rate
( in Rs.)
2013-2014
5

Sr No

Item Description

Unit

2
Designing, providing and constructing administrative building,
office cum laboratory including stores. This shall be a building
having apropriate carpet area . at ground floor and at first
floor complete as per specifications including necessary
excavation, foundation in RCC M-200 framed structure B. B
Masonry ( II -class in C.M. 1:6) 20 mm thk cement plaster in
CM 1:3 inside and outside painting. Aluminum door and
window with glass panels, ceramic tile flooring and skirting
and all other allied items, fixtures fastening electrification
arrangement water supply arrangement etc. complete. The
building will have laboratory on upper floor of administrative
building and should be so centralized that it should not be
attached with any unit but should have complete control of
every unit as per laboratory equipment, beautification,
telephone arrangements PLC Panel & Computer housing,
Tool room, workshop etc.

15

Land development and allied works ---. This includes


landscaping, gardening area lighting plantation roads and
pathway, storm water drainage in STP campus as directed by
Engineer in charge.
Various Units of the Plant shall be operated automatically
based on PLC /SCADA operating system as per detailed
specification
In MLD
UP to 10

MLD

Cost of 10 MLD
Above 10 to 20

MLD

Cost of 20 MLD
Above 20 to 35

MLD

Cost of 35 MLD
Above 35 to 50

MLD

Cost of 50 MLD
Above 50 to 75 MLD

MLD

Cost of 75 MLD
Above 75 to 100

MLD

Cost of 100 MLD


Above 100 MLD

Notes :The rates for civil work, RCC M30 grade for water retaining
structures and M20 Buildings
( partition walls of biotower
shall be in BB masonry in CM 1;6,with smooth cement
plaster inside in CM 1;4 and sand faced plaster in CM 1;6
outside) ,Misc works.

b Water table is considered at 5m below ground level


c Soil Bearing Capacity considered as 20 T/m2 at 1.5m below
ground level

MLD

Rate
( in Rs.)
2012-2013
4

Rate
( in Rs.)
2013-2014
5

Sr No

Item Description

Unit

2
OPC cement and steel Fe 415 has been considered for
casting purpose

e All civil items , are considered as per MJP/PWD Schedule of


rates

f For STP up to 20 MLD capacity Sludge Drying Beds are


g

considered and for above capacities centrifuge shall be


provided.
For STP up to 20 MLD capacity Naocl dosing is considered in
for above capacities gas chlorination shall be provided .

f All equipment shall be procured from MJP approved vendors


4E

SECTION - I : (XIX) MOVING MEDIA BIO REACTOR


TECHNOLOGY
PROCESS DESCRIPTION - MOVING MEDIA BIO REACT
TECHNOLOGY
The Moving Media Bio Reactor Technology is a advanced
biological treatment process which has a combination of
activated sludge process & attached growth process. The bio
reactor has lot of packing material called carrier media in
suspension and provides a large surface area for micro
organisms to grow and degrade the organic matter in aerobic
condition. Due to the use of carrier media the higher
concentration of bio mass is developed which helps to reduce
the basin size, accept higher loading rates & take shock loads.
The sewage after screening & grit removal flows by gravity
into the BIO REACTOR wherein the attached growth, aerobic
microbes will utilize pollutant in presence of oxygen thereby
further reducing BOD. The air required will be provided
through coarse bubble air diffusers provided on the aeration
grid at the bottom of reactor & using positive displacement,
twin lobe, root type air blower for supply of oxygen.
The PP media is provided in the aeration tank to allow the
aerobic microbes to grow & get attached. This media remains
in fluid state in the aeration tank thereby keeping large number
of microbial colonies moving in the tank and provide high
concentration of bio mass available at all the time. The
microbes get exposed to bio degradable organics in presence
of oxygen and convert it into Cell biomass, Water molecule
and Carbon dioxide. The microbial colony grows on plastic
media. The excess biomass gets sloughed and moves with
treated water into subsequent unit. This sloughing action is a
continuous process and the microbes keep on growing &
sloughing. This is a very fast process & hence system
becomes self sustaining.

Rate
( in Rs.)
2012-2013
4

Rate
( in Rs.)
2013-2014
5

Sr No

Item Description

2
The dead biomass generated will be separated in the
CLARISETTLER TANK wherein tube media is provided for
providing additional surface area for settlement of bio mass &
thereby reducing the space requirement. The solid-liquid
separation is achieved in this tank and clear supernatant will
flow by gravity.
The treated wastewater will be disinfected with Chlorine and
allowed to react in CHLORINE CONTACT TANK prior to
suitable disposal.
A typical sketch of bio reactor showing various components is
given below.
The MMBR/FAB Technology has following advantages over
Conventional Systems like :

1
2
3
4
5
6
7
8
II

Low on Civil works.


Low Space Requirement
Low on Operating Cost due to higher Oxygen Transfer
Efficiency.
Low on Maintenance Cost.
Easy to operate with Semi-skilled manpower.
Higher efficiencies in pollutant removal.
Effective removal of nitrates and phosphates.
Quick retrieval of system after shutdown / power failure.
SPECIFICATIONS OF SEWAGE TREATMENT SCHEME
Raw Sewage Characteristics
Temperature
Ambient
pH
7.0-8.0
Total Suspended Solids
210 mg/l
BOD 5 days at 20 C
170 mg/l
COD
Oil & Grease
MPN
Treated Sewage Quality
pH
Total Suspended Solids
BOD
COD
Oil & Grease
MPN

340 mg/l
30 mg/l
106 to 107 per 100 ML
6.5-8.5
< 30 mg/l
< 20 mg/l
< 100 mg/l
< 10 mg/l
< 1000 per 100 ML

Moving Media Bio Reactor (MMBR) / FAB


(Fluidised Aerated Bed) Process

Unit

Rate
( in Rs.)
2012-2013
4

Rate
( in Rs.)
2013-2014
5

Sr No

Item Description

Unit

2
Designing, providing, construction, hydraulic testing,
commissioning and giving satisfactorily trials of STP consisting
of Inlet Chamber, screen chamber, Grit Separator, MMBR /
FAB (Based on technologies providing attached growth on
plastic meddi kept suspended in the waste water due to low
density of plastic & provided with compressed air for aeration
with very high MLSS of greater than 15,000 mg/lit.) tank,
Secondary Clari settler, Sludge sump, Sludge Thickener,
Chlorine Contact Tank, Chlorinator room/Shed, sludge
Centrifuge, associated piping work with required valves,
gates, drains, pathways, Administration Block cum
Laboratory, Laboratory Equipments, spares parts for 2 years
of operation, etc. complete as turnkey job with all involved
civil, electrical and mechanical works inclusive of following
items, units as per detailed specifications for civil, electrical
and mechanical components with all duties and taxes etc.
complete. Treated sewage can be used for irrigation,
horticulture purposes.

FOLLOWING UNITS ARE INCLUDED


1. Inlet Chamber
Designing, providing and constructing RCC (M:25) inlet
chamber designed for the peak flow including necessary
excavation in all types of strata including walkway all around
the periphery. Each compartment will have CI gates with
extension rod. Head stock, operating wheels, GI pipe railing
etc. The work includes providing and making necessary
arrangements to connect the flow to screen chamber by
approach channel as directed and as per specifications.
2. Screen Chamber
Designing, providing, constructing, testing and commissioning
of screen chamber, designed for peak flow in RCC (M-25),
including walkway 1.2 m wide with GI pipe.
3. Grit Separator
Designing, providing & constructing detritor type grit removal
mechanism in RCC (M-25) capable of removing 100% 0.2 mm
size particle & above having specific gravity 2.30 designed for
peak flow with suitable arrangement of separation of grit from
putrescible solids including providing & making necessary
arrangements of Jb-1. Inlet & outlet channels of required sizes
as make be required to connect the flow to connecting unit etc.
complete including hydraulic testing for water tightness of
structure having minimum FB of 0.3 m, wash out arrangement
to grit chamber & platform 1.2 m wide RCC walkway with GI
pipe handling shall be provided. A pit for collecting grit
conveyed by conveyor shall be provided. It should be suitable
to handle the grit for carting. All arrangements shall be as
detailed specifications and as directed.
4. MMBR / FAB Tank

Rate
( in Rs.)
2012-2013
4

Rate
( in Rs.)
2013-2014
5

Sr No

Item Description

Unit

2
Designing, providing & constructing in RCC (M-25) biological
reactor tank for removal of BOD along with nutrient removal to
handle the average flow & having hydraulics suitable to handle
peak flow conditions with suitable 1.2 m wide walk way,
expansion joints as required, including foundation etc as per
specifications. The tank shall be equipped with inlet & outlet
arrangement, air blowers for supply of air, coarse bubble
diffusers & aeration grid in SS 304, PP carrier bio media etc.
FB of 0.5 m & SWD as required should be complete as per
detailed specifications.

5. Secondary Clarisettler
Designing, providing & constructing in RCC (M-25) water tight
secondary clarisettler having SWD of 3.75 m + 0.5 m FB & has
tube media in the clarification zone to provide additional
surface area for settling. The settler shall be provided with a
scraper mechanism in MS with epoxy painting for collecting
the settled solids at the bottom (bottom slope 1:12). The
central feed well shall be made of MS with epoxy painting from
both faces & well stiffened. The sewage will be admitted in the
feed well & then will move outwards towards periphery slowly
& continuously over a weir & will be collected in a launder.
6. Chlorine Contact Tank
Designing, providing & constructing chlorine contact tank of
adequate capacity to deal with average flow. The contact time
provided is 30 mm to achieve 99.99 % reduction in coliform
during average flow condition. Chlorine dosage will be as per
standard provisions including designing, providing &
constructing water supply provisi9n for chlorination, including
providing dewatering & by pass arrangement for joining to final
effluent mains & outlet weir etc complete. The effluent quality
should match with the standards laid down by Maharashtra
Pollution Control Boars & as per obligatory provision & as
detailed specification & as directed by engineer in charge.
7. Chlorinator & Chlorinator Room / Tonner Room
Designing, providing & constructing vacuum type chlorinators
having adequate capacity for dosage of adequate chlorine to
ensure 99.99% coliform reduction as per obligatory provisions
detailed specifications with necessary provision of having
chlorinator room of adequate size. The chlorinator equipment
shall include chlorine cylinders I tonners, piping, valves,
measuring controlling equipments, safety devises, lifting
equipment etc. complete as per IS 10553 (Part II) 1982. The
tonner room should have mm 3 MT capacity crane for loading
& unloading facility. Tonner storage should be distinctly
isolated and should have min. storage space as per the
detailed specifications & as per gas law 1981 & factory act
shall be provided. All other matching amenities shall be
provided, 5 MT gantry rail shall be provided for full length of
tonner room a 6 m Ht from level of tonner room with outlet.
8. Sludge Sump

Rate
( in Rs.)
2012-2013
4

Rate
( in Rs.)
2013-2014
5

Sr No

Item Description

Unit

2
Designing, providing & constructing of sludge sump and pump
for discharging sludge to sludge thickener using MS pipe
complete as per detailed specification.

9. SIudge Thickener
Designing, providing & constructing water tight of sludge
thickener - gravity type in RCC (M-25) with inlet & outlet pipes,
central feed well, sludge it & sludge removal arrangement,
grouting wherever necessary with walkway all around of 1.20
m with GI pipe railing interconnecting CI pipes all complete as
per specifications, having bottom slope 1:8 & 3 m SWD with
necessary fixed bridge scraper arrangement as per detailed
specifications & necessary inlet & outlet arrangement. All
other arrangement as per detailed specifications.
10. Sludge Centrifuge Platform with Centrifuge
Designing, providing, constructing & installing including
foundation etc. Sludge centrifuge to handle the sludge flow of
1 day in 18 hrs per unit with sludge dewatering unit drain etc
complete is per specification. Sludge centrifuge with
necessary arrangements as per detailed specification
mentioned in tender and obligatory provisions to be provided
with satisfactory functioning.
11. Outfall sewer
Designing, providing, constructing appropriate outfall sewer of
RCC NP2 pipe to discharge treated effluent, untreated effluent
from outlet chamber (after basin / chlorination tank) to the local
Nallah at the point shown on the drawing including necessary
chambers for inspection & cleaning including excavation,
dewatering, refilling, concrete encasing I bedding concrete.
12. Pining work in CI- LA class including sluice valves,
reflux valves, MS Gates
Providing, laying & jointing pipes other than hose already
included in the above items for interconnection by pass drains
etc. of all units including adequate numbers of manhole
chambers. The item includes excavations, refilling & hydraulic
testing of pipes, valves, gates, accessories & cost of jointing
materials. The item includes required channels with gates or
interconnection of units, by pass drains etc. for ill units as
directed etc complete as per detailed specifications.
13. Administrative Building cum Laboratory (G+1)

Rate
( in Rs.)
2012-2013
4

Rate
( in Rs.)
2013-2014
5

Sr No

III

1
2

Item Description

2
Designing, providing & constructing administrative building,
office cum laboratory including stores. This shall be building
having appropriate carpet area & ground floor & at first floor
complete as per specifications including necessary
excavation, foundation in RCC M 20 framed structure, BB
masonry (II class in CM 1:6) 20 mm cement plaster in CM 1:3
inside & outside painting, aluminum door & window with glass
panels, mosaic tile flooring & skirting & all other allied items,
fixtures, fastening, electrification arrangement, water supply
arrangement etc complete. The building will have laboratory
on upper floor of administrative building & should have
complete control of every unit as per laboratory equipment,
beautification, telephone & intercom arrangement & wireless
system.
PRICE SCHEDULE
Capacity of the Plant

1
600
3
900
5
1200
8
2000
10
2300
13
2700
15
3200
18
3600
20
3900
25
4750
NOTES
Screen chamber & grit separator up to 5 MLD Capacity are
manual type.
Up to 5 MLD Capacity STP chlorination is done by using
sodium hypochlorite solution. Above 5 MLD capacity gas
chlorinator is provided.
Sludge thickener is not provided up to 3 MLD capacity STP.
Sludge will be collected into sludge sump & pumped directly to
sludge dewatering system

For all STP sludge dewatering is using solid bowl centrifuge.

Chlorinator room not provided for STP up to 3 MLD. For STP


up to 3 MLD laboratory I administration building is not
provided. Only a room for operator is provided.

Boundary wall, fencing, gate, storm water drains, site


clearance is not considered in scope.
All water retaining structures are in M 30 grade of concrete.

8
9

Area required in Sqm

Unit

10

Water table is considered 5 m below GL for design.


Soil bearing capacity is considered as 20 TIm2 at 1.5 m below
GL.
Lead for excavation is considered as 0.5 km.

11

Grade of cement used is OPC 43 grade.

12

Grade of steel used is Fe 415.

.
MLD
MLD
MLD
MLD
MLD
MLD
MLD
MLD
MLD
MLD

Rate
( in Rs.)
2012-2013
4

Rate
( in Rs.)
2013-2014
5

Sr No

13
14

Item Description

2
Peak factor considered for design for plants up to 3 MLD is 3,
4 to 15 MLD is 2.5,16 to 20 MLD is 2.0.

IV

Chemicals required during trial run & commissioning is not


considered.
Water & power during construction, trial run & commissioning
shall be provided by client.
Power available at STP location is assumed as LT power
supply.
MAKES OF EQUIPMENT

S.No.
1

Description
Centrifugal Pumps

Screw Pumps

Air Blower

Dosing Pumps

15
16

Unit

Rate
( in Rs.)
2012-2013
4

Make
Kirloskar / Jhonson /
Kishor / Eqv.
Roto / Tushaco / Eqv.
Usha / Swam / Kay /
Kulkarni / Eqv.
Milton Roy / VK Pumps
/ Positive /
Minimax / Eqv.

Agitators / Flocculators

Pavan / Fibre & Fibre /


Ceecons

Clarifier / Thickener Mechanism

To be fabricated as per

Screens

MJP approved design /


make
To be fabricated as per

MJP approved design /


make
8

Grit Separator

To be fabricated as per
MJP approved design /
make

Chlorinator

10

Chlorine Tonner

11

Solid Bowl Centrifuge

12

Motors

13

Cables

14

MS pipes

Toshcon Jesco /
Banaco / Perfect
Chloro /
Chlorocontrol / Metito /
Eqv.
Meenakshi / Eqv.
Alfa Laval / Humbolt /
Wedag/ Hiller/ Eqv.
Crompton/ Siemens/
Lakshmi
Finolex/ Polycab
Mahalakshmi
Seamless/
Maharashtra
Seamless/

Rate
( in Rs.)
2013-2014
5

Sr No

Item Description

15

CI Pipes

16

Valves

17

Clarisettler Media

18

Bio Reactor Carrier Media

Unit

Rate
( in Rs.)
2012-2013
4

Suryaroshni/ Jindal/
Eqv.
Truform/ Electrosteel/
Kejriwal/ Eqv.
Intervalve/ BDK/
Procon/ Tyco/
AV valves/ Eqv.

4F

Cyclic Activated Sludge Process

Designing , providing, constructing, hydraulic testing,


commissioning and giving satisfactory trials of STP based on
SBR technology consisting of Inlet Chamber, Screen
Chamber, Detritus Tanks, Distribution Chamber and Biological
CASP Basins, Sludge Sump, Chlorine Contact Tank,
Chlorinator Room/Shed, Sludge Centrifuge necessary piping
work with required valves, gates, drains, pathways
administration Block cum Laboratory, Laboratory Equipments,
Tools and Plants, Spare Parts, etc. complete as turnkey job
with all involved civil, electrical and mechanical works inclusive
of following items, units as per detailed specification for civil,
electrical and mechanical components with all duties and
taxes etc. complete to achieve BOD < 5 ppm, COD < 100
ppm, TSS < 10 ppm, to get recyclable quality of water for
industrial / agricultural purposes. (In Case Cyclic activated
sludge plant is designed for N, P outlet parameters shall also
include TN < 10 ppm, Nh3N < 2 ppm and TP < 1 ppm)
UNITS INCLUDED
1. Inlet Chamber
Designing, providing, and constructing RCC (M:250) inlet
chamber for the peak low of 2 DWF including necessary
excavation in all types of strata including walkway all around
the periphery. Each compartment will have phosphor bronze
steel gates with extension rod, head stock, operating wheels.
GI pipe railing etc. The work includes providing and making
necessary arrangements to connect the flow to screen
chamber by approach channel as directed and as per
specifications.
2. Screen Chamber
Designing, providing, constructing, testing and commissioning
of screen chamber, designed for average 1 DWF and
maximum peak flow of 2 DWF in RCC (M -250), including inlet
pipe / channel from inlet chamber, outlet pipe channel to
detritus tank, free board of 0.5 m minimum, RCC walkway 1.2
m wide with GI pipe railing, RCC stair case of 1.2 m width from
GL to screen chamber.
3. Detritus Tank

Cooldeck/ Munters
As per MJP approved
design / make

Rate
( in Rs.)
2013-2014
5

Sr No

Item Description

Unit

2
Designing, providing and constructing continuous grit removal
type of Detritus Tank, mechanically operated in RCC (M 250)
capable of removing 100% of 0.2 mm size particle and above,
having specific gravity 2.30 designed for one peak 2 DWF with
suitable arrangement of separation of grit from putrescible
solids. Inlet and outlet channels of required sizes as may be
required to connect the flow to connecting unit etc. Complete
including hydraulic testing for water tightness of structure
having minimum FB of 0.3 m, wash out arrangement to Grit
chamber and platform 1.2 m wide RCC walkway with GI pipe
handling shall be provided. A pit for collecting grit conveyed by
conveyor shall be provided. It should be suitable to handle the
grit for carting. All arrangements shall be as detailed
specifications and as directed.

4. CASP Basins
Designing, providing and constructing in RCC (M:250), CASP
basins for biological removal of BOD along with nitrification,
denitrification, Bio-P removal in compartments to handle
combine flow of 1 DWF incoming flow and recirculation flow
including construction of selector compartments and providing
1.2 m wide clear approach walkways, expansion joints
wherever necessary, including foundations etc as per
specifications. Peak factor shall be 2, F/M ration shall be 0.15,
complete with air blowers, fine diffused aeration grid /
equipment and FB 0.5 m and SWD as required. DO level in
basin to be minimum 2 mg/l complete with "Oxygen Uptake
Rate" control system and all related instruments. Stainless
steel decanters and automation works. MLSS concentrations
shall be 2000-5500 mg/l or more, MLVSS to MLSS ratio to be
0.8. HRT shall be between 12 to 13 hrs and SRT suitable for
fully disgested sludge. It should have all other related works as
per detailed specification. In Case CASP is designed to
achieve N, P removal HRT shall be between 15-18 hrs and
SRT shall be suitably provided to achieve N, P removal.
5. Chlorine Contact Tank
Designing providing and constructing chlorine contact
chamber of adequate capacity to deal with 1 DWF average
flow. The chlorine contact tank should be 30 min capacity,
during average flow to achieve 99.99% coliform reduction.
Chlorine dose shall be maintained as per standard provisions,
including designing, providing and constructing water supply
provision for chlorination including providing dewatering and
by pass arrangement jointing to final effluent mains and outlet
weir, etc complete. The effluent quality should match with the
standards laid down by Maharashtra water pollution control
board and as per obligatory provision and as detailed
specification and as directed by Engineer-in-charge.
6. Chlorinator and Chlorinator Room / Tonner Room

Rate
( in Rs.)
2012-2013
4

Rate
( in Rs.)
2013-2014
5

Sr No

Item Description

Unit

2
Designing, providing and constructing chlorinators vacuum
type 2 Nos. with auto switchover facility and having capacity
for dosage of adequate chlorine to ensure 99.99% coliform
reduction as per obligatory provisions and detailed
specifications with necessary provision of having chlorinator
room of adequate size. The chlorinator equipment shall
include cost of chlorine cylinders / tonner piping, valves,
measuring and controlling equipments, safety devices, lifting
euipments, etc. complete as per IS-10553 (part II) 1982. The
tonner room should have minimum 3 MTcapacity Hoist for
loading and unloading facility. Tonner storage should be
distinctly isolated and should be for minimum storage space
as directed in the design specification and as per gas laws
1981 and factory act shall be provided. All other matching
amenities shall be provided, 5 MT gantry rail shall be provided
for full length of tonner room at 6 m height from level of tonner
room, with outlet chamber and treated effluent outlet channel
etc. complete as per detailed specification.
7. Sludge Sump
Designing, providing and constructing of sludge sump and
pump house of appropriate size with pumps, ceiling height
minimum 6 m over sump for discharging sludge to centrifuge
using CI pipe complete as per detailed specification.

8. Sludge Centrifuge Platform with Centrifuges


Designing, providing, constructing and installing including
foundation etc., sludge centrifuge to handle the sludge flow of
1 day in 20 hours per unit with sludge dewatering unit drain etc
complete as per specification. Sludge centrifuges with the
necessary arrangement, as per detailed specification
mentioned in tender and obligatory provisions to be provided
with satisfactory functioning.
9. OutfaIl Sewer
Designing, providing and constructing appropriate outfall
sewer of RCC NP2 pipe, to discharge treated effluent from
outlet chamber after chlorination tank to the local Nallah at the
point shown on the drawing including necessary chamber for
inspection and cleaning including necessary excavation,
dewatering, refilling concrete encasing / bedding concrete
steps to reach the nallah bed level, pitching and energy
dissipation chamber in nallah portion etc. complete upto 50 m
length RCC NP2 pipe line and including all above items.
10. Piping work in CI-LA Class including Sluice valves,
Reflux Valves,
MS gates

Rate
( in Rs.)
2012-2013
4

Rate
( in Rs.)
2013-2014
5

Sr No

Item Description

Unit

2
Providing laying and jointing pipes other than those already
included in the above items for interconnection by - pass
drains etc. of all units including adequate numbers of manhole
chambers. The item includes excavations, refilling and
hydraulic testing of pipes, valves, gates, accessories and cost
of jointing materials. The items includes required channels
with gates for interconnection of units by pass drains etc for all
units as directed etc complete as per detailed specifications.

11. Administrative Building cum Laboratory (G+1)


Designing, providing and constructing administrative building,
office cum laboratory including stores. This shall be a building
having appropriate carpet area and ground floor and at first
floor complete as per specifications including necessary
excavation, foundation in RCC M 200 framed structure B. B
masonry (11- class in C.M. 1:6) 20 mm cement plaster in CM
1:3 inside and outside painting. Aluminium door and window
with glass panels, mosaic tile flooring and skirting and all other
allied items, fixtures fastening electrification arrangement
water supply arrangement etc complete. The building will have
laboratory on upper floor of administrative building and should
be so centralized that it should not be attached with any unit
but should have complete control of every unit as per
laboratory euipment, beautification, telephone and intercom
arrangement and wireless system.

Capacity in MLD Area required


1
0.50
2
0.6
5
0.65
10
0.7
15
0.75
20
0.80
25
1.00
30
1.20
40
1.60
50
1.75
60
1.90
75
2.25
100
2.40
125
3.00
150
3.50

No. of Basins
2
2
2
2
2
4
4
4
4
4
4
4
6
6
6

NOTES
These Rates are for Civil Works, in M30 grade RCC.

Water Table is considered at 5 m below ground level.

Soil bearing capacity considered as 20 T/m at 1.5 m below


ground level.

MLD
MLD
MLD
MLD
MLD
MLD
MLD
MLD
MLD
MLD
MLD
MLD
MLD
MLD
MLD

Rate
( in Rs.)
2012-2013
4

Rate
( in Rs.)
2013-2014
5

Sr No

Item Description

2
OPC has been considered for costing purposes.

All civil items, electrical, piping, valves, pumps, motors,


blowers, etc. are considered as per MJP Schedule of Rates.

I. No.1,2 includes sludge drying beds instead of sludge


centrifuge and DWPE dosing system.

I. No.1,2,3 includes NaOCI Dosing System instead of Gas


Chlorination.

I. No.1,2,3 do not includes Lab and Lab Equipments.

Unit

Rate
( in Rs.)
2012-2013
4

Rate
( in Rs.)
2013-2014
5

Section - I - ( XVIII ) - R.C.C. G.S.Rs and Sumps


Unit
Item Description

Sr No

Designing (aesthetically), and constructing RCC ground service


reservoirs / RCC sumps in M-300 mix. of required capacity including
excavation in all types of strata, foundation concrete, container walls,
bottom slab top RCC roof slab / or dome, 20 mm thick cement plaster
with water proofing compound in CM 1:3 proportion. to inside face of the
container, including epoxy paint from inside including refilling and
disposing of surplus stuff within lead of 50 M, all labour and material
charges, for laying and jointing of pipe assembly for inlet, outlet washout,
over flow and bye-pass arrangement consisting of C.I./ M.S. D/F. pipes,
specials and valves of given diameters.
providing and fixing accessories such as M.S. ladder inside and outside,
C.I. Manhole frame and cover, at top slab, B.B. masonry chamber for all
valves, ventilating shafts, including giving satisfactory hydraulic test and
water tightness test as per IS code and providing three coat of cement
paints to all expose surface of structure including roof surface etc.
complete as per design data, criteria, obligatory requirements and
detailed specifications.Anti-termite treatment shall be given for
underground portion of the structure.
Note:1. The designing shall be in accordance with various relevant I.S.
specification ( I.S. 456/2000, I.S. 875- 1987, I.S. 3370-1965 or revised
2. Only M.S bars grade I confirming to I.S. 432 Part_I or high yield
strength deformed bars confirming to I.S. 1786 or I.S. 1139 shall be
used grade II M.S. bars shall not be used
3) Entire structure shall be in M-300 only.
4) The scope of pipe assembly work shall be upto 5 Meter beyond
outside face of the wall, cost of pipes valves and specials is not included
in the rate but labour cost for laying and jointing is included
5) The G.S.R./ Sump above 15 lakh liter capcity shall be in two
compartment
6) The job includes designing the structure for uplift pressure and
dewatering if require duing entire execution and disposal of surplus
excavated stuff with in lead of 50 Meters as directed by Engineer-incharge. If up lifts considered in design then these rate shall be increased
by 7.5%
7) G.S.R. outlets shall be with bell mouth of approved pattern in bottom
slab and cost of designing bell mouth is included in the rate Sump well
includes cost of suction pit required at bottom.
8. For pipes diameters upto 300mm only CI pipes and CI specials shall
be used. For pipe diameters above 300mm M.S. pipes and specials of
thickness minimum 10mm shall be used with proper anticorrosive epoxy
treatement from inside and outside
9) Cost of pump house is not included in these rates.
10) Above rates are applicable for seismic zones- 2,3, and 4
11) 75% part rate shall be payable for reinforcement, concrete and
plastering items of all types of G.S.R's and sumps till satisfactory
hydraulic testing for water tightness test is given ; and till that work shall
be treated as incomplete.

Rate
( in Rs.)
2012-2013

Rate
( in Rs.)
2013-2014

Sr No

Item Description

Unit

Rate
( in Rs.)
2012-2013

Note:-1) Condition from Sr.No.1 to 11 shall form a part and parcel of


tender and must be included in the Draft tender papers for work of RCC
GSRs and sump.
2) 10 % payment shall be added over the cost of GSR for sump
where overhead pumphouse is proposed.
Rates for RCC GSRs or sumps.
Capacity in litre
1

Upto 25,000 Litre

Cost of 25,000 Capacity

Add for capacity 25,000 to 50,000 Litre

Cost of 50,000 Capacity

Add for capacity 50,000 to 75,000 Litre

Cost of 75,000 Capacity

Add for capacity 75,000 to 1,00,000 Litre

Cost of 1,00,000 Capacity

Add for capacity 1,00,000 to 1,50,000 Litre

10

Cost of 1,50,000 Capacity

11

Add for capacity 1,50,000 to 2,00,000 Litre

12

Cost of 2,00,000 Capacity

13

Add for capacity 2,00,000 to 3,00,000 Litre

14

Cost of 3,00,000 Capacity

15

Add for capacity 3,00,000 to 5,00,000 Litre

16

Cost of 5,00,000 Capacity

17

Add for capacity 5,00,000 to 10,00,000 Litre

18

Cost of 10,00,000 Capacity

19

Add for capacity 10,00,000 to 15,00,000 Litre

20

Cost of 15,00,000 Capacity

21

Add for capacity avove 15,00,000 Litre

Unit
Per Lit
Per Lit
Per Lit
Per Lit
Per Lit
Per Lit
Per Lit
Per Lit
Per Lit
Per Lit
Per Lit

12.26
306500.00
7.13
484750.00
5.94
633250.00
5.35
767000.00
5.04
1019000.00
4.75
1256500.00
4.16
1672500.00
3.56
2384500.00
2.97
3869500.00
2.38
5059500.00
1.78

Rate
( in Rs.)
2013-2014

Section - I - ( XIX ) - R.C.C. E.S.Rs


Sr No

Item Description
1

Designing (aesthetically), and constructing RCC elevated service


reservoirs of following capacity with RCC staging consisting of
columns, internal and external bracings spaced vertically not more
than 4.5 meters centre to centre for E.S.R. having capacity 500 m3 &
not more than 6 m c/c for E.S.R.having capacity above 500 m3
including excavation in all types of strata, foundation concret, cement
plaster with water proofing compound to the inside face of the
container including refilling disposing of the surplus stuff within a lead
of 50 meters, all labour and material charges including lowering,
laying, erecting, hoisting and jointing of pipe assembly of inlet, outlet,
washout, overflow and bypass arrangements as per departmental
design.
providing and fixing accessories such as M.S. ladder, C. I. manhole
frame and covers water level indicatiors, lightening conductor, G. I.
pipe railing around walk way and top slab, providing spiral staire case
from ground level to roof level, M.S.Grill gate of 2 Mtrs height with
locking arrangement, B.B. masonry chambers for all valves,
ventilating shafts, providing and applying three coats of cement paint
to the structure including roof slab and epoxy paint to internal surface
& anti-termite treatment for underground parts of the structures and
giving satisfactory water tightness test as per I.S. code, The job to
include painting the name of the scheme and other details on the
reservoir as per the directions of Engineer-in-charge.

Notes:
1. The design of the structure be in accordance with relevent
(I.S.3370 - 1965 or revised)
2. The design shall satisfy the stipulation as per IS 1893-1984 and
I.S. 13920/1993 for seismic focrce and I.S.- 11682/1985 for R.C.C.
staging of overhead tanks.
3. For design having more than 6 columns, Providing of internal
bracing is obligatory,. External bracking is also obligatory.
4.. The entire structure shall be in M 300 mix only.
5. Plain round mild steel bars grade - I confirming to I.S,432 Part-I or
high yield strengh deformed bars confirming to I.S. 1786 or I.S. 1139
shall be used, grade-II mild steel bars will not be allowed.
6. Irrespective of the type of foundation proposed in the design, one
set of bracing be provided at the gound level.
7. These rates include providing, M.S. ladder for E.S.R's upto 2 lakhs
liters capacity and providing sprial staircase for E.S.R. above 2 lakhs
liters capacity.
8. Stagging shall have to be designed with stresses of M-200 for
ESR. However all RCC construction should be done in M-250
9. These rates are including the cost of uplift pressure if any and
entire dewatering during execution. In case of water logging area
where water is struck at shallow depth extra provision of dewatering
shall be made as per site condition.
10. All condition given in the Member Secretary"s Circular
No.MJP/TS-I/350/1668 dt. 2.8.97 and MJP/S-I/350/2127 dt. 13.7.99
shall be strictly followed and additional cost, if any due to these
conditions is included in the rates mentioned below.

Unit

Rate
( in Rs.)
2012-2013

Rate
( in Rs.)
2013-2014

Sr No

Item Description
11.. 75% part rate shall be payable for reinforced cocnrete and
plastering items of containers of E.S.R. till satisfactory hydraulic
testing for water tightness is given ; and till that work shall be treated
as incomplete.
12. The rates indicated in the table are excluding the cost of pipes,
specials and valves required for inlet, outlet washout overflow and bypass arrangement. The scope of work, however inclueds cost of
erecting, laying and jointing of pipes and valvews including cost of
jointing materials upto 5M beyond outer face of outermost column.
13. For ESR upto 500cum capacity C.I.D. double flanged pipes upto
300mm dia shall be provided and C.I.Specials shall be used.For ESR
above 500 cum capacity C.I./M.S. pipes assembly with minimum
8mm thick ness up to 500mm dia. And minimum 10mm thickness
above 500mm dia can be used with proper anti-corrosive epoxy
teratment from inside and outside.
14. Below mentioned rates are for foundation, with individuals footing
with bearing capacity of 30 tonnes per square metre. For raft
foundations, these rates shall be increased by 7.5%
wheresafebearing capacity ( SBC) is 5 M.T. per Sq.m and by 5%
where SBC is more than 5 MT/Sqm. and upto 10MT/Sq.m. This
percentage of 5% or 7,5% is applicable for estimation of amount of
L.S. items ESR for Extra item due to change from individual footing
foundation to raft actual increase in concrete and steel quantities be
paid as per relevent DSR Item.
15. The rates shall be increase by 30% for brearing piles upto depth
of 10m and for further increased in depth by 5M each it shall be
increased by another 10% These rates are applicable where raft is
not reasible for pile foundation sulfate resistant cement shall only be
used. Single pile for the column is not permitted Group of piles shall
be designed with pile cap for each column of ESR.
16. These rates are applicable for staging height of 12 M These
rates shall be increased or decreased for per metre variation in the
staging height as below
12 to 16 M staging
2% per metre
16 to 20m staging
3% per meter
20 M and abovd - 4% per metre
I.e. for 17m stagging height
percentage calculation will be like below
12 to16m = 4 x 2
= 8%
16 to 17 m x 1 x 3
= 3%
Total
= 11 %
For 21 m stagging height
Percentage calculation will be like below
12 to 16m = 4 x 2
= 8%
16 to 20m = 4 x 3
= 12%
20 to 21m = 1 x 4
= 4%
Total
= 24%
17. Following rates are for seismic zone-III for Zone-IV these rates
shall be increased by 5% and for Zone-II, these rates shall be
decreased by 5% concerned Executive Engineer shall confirm the
seismic zone for the scheme from seismic zones plan before
estimation and adopt appropriate rates as per actual seismic zones(
Seismic maps attached in this C.S.R.)

Unit

Rate
( in Rs.)
2012-2013

Rate
( in Rs.)
2013-2014

Sr No

Item Description

Unit

Rate
( in Rs.)
2012-2013

Unit

for Seismic
Zone- III Rate
in Rs.

23.76
594000.00
13.07
920750.00
9.50
1158250.00
8.32
1366250.00
7.13
1722750.00
5.94
2019750.00
5.64
2301750.00
5.35
2569250.00
5.04
3073250.00
4.75
3548250.00
4.45
4660750.00
4.16
5700750.00
3.86
7630750.00
3.56
9410750.00

Note:- 1) Conditin from Sr.No.1 to 11 shall form a part and parcel of


the tender papers and shall be included in the DTP for works of
R.C.C.E.S.R.
Note:- 2) Condition from Sr.No.12 to 17 are for estimation purpose
only and shall not be appear in the tender.

Capacity in litres

upto 25,000 litre

Litre

Cost of 25,000 Litre capacity E.S.R.

------

Add for capacity above 25,000 upto 50,000 litre

Litre

Cost of 50,000 Litre capacity E.S.R.

------

Add for capacity above 50,000 upto 75,000 litre

Litre

Cost of 75,000 Litre capacity E.S.R.

------

Add for capacity above 75,000 upto 1,00,000 litre

Litre

Cost of 1,00,000 Litre capacity E.S.R.

------

Add for capacity above 1,00,000 upto 1,50,000 litre

Litre

10

Cost of 1,50,000 Litre capacity E.S.R.

------

11

Add for capacity above 1,50,000 upto 2,00,000 litre

Litre

12

Cost of 2,00,000 Litre capacity E.S.R.

------

13

Add for capacity above 2,00,000 upto 2,50,000 litre

Litre

14

Cost of 2,50,000 Litre capacity E.S.R.

------

15

Add for capacity above 2,50,000 upto 3,00,000 litre

Litre

16

Cost of 3,00,000 Litre capacity E.S.R.

------

17

Add for capacity above 3,00,000 upto 4,00,000 litre

Litre

18

Cost of 4,00,000 Litre capacity E.S.R.

------

19

Add for capacity above 4,00,000 upto 5,00,000 litre

Litre

20

Cost of 5,00,000 Litre capacity E.S.R.

------

21

Add for capacity above 5,00,000 upto 7,50,000 litre

Litre

22

Cost of 7,50,000 Litre capacity E.S.R.

------

23

Add for capacity above 7,50,000 upto 10,00,000 litre

Litre

24

Cost of 10,00,000 Litre capacity E.S.R.

------

25

Add for capacity above 10,00,000 upto 15,00,000 litre

Litre

26

Cost of 15,00,000 Litre capacity E.S.R.

------

27

Add for capacity above 15,00,000 upto 20,00,000 litre

Litre

Cost of 20,00,000 Litres capacity E.S.R.

------

28

Rate
( in Rs.)
2013-2014

Section - I - ( XX ) - Chambers, Manholes and Drainage Drops


Sr No

Item Description
1

Unit

Rate
( in Rs.)
2012-2013

Providing and constructing B.B. masonry valve chamber with 15 cm


thick 1:3:6 proportion PCC bedding, excluding excavation, B.B.
masonry in C.M. 1:5 Proportion precast RCC frame and cover, etc.
complete as directed by Engineer-in-charge.
Note: Wall thickness : 0.23 M for depth of 1.2 M and 0.35 M for
balance depth exceeding 1.2 M )

Valve Chamber with Precast R.C.C. covers.


A.

As above of 60 x 45 cm internal size and depth upto 0.9M .


a). Add for every increase of depth of 30cm or part thereof.

B.

As above of 90 x 45 cm internal size and depth upto 1.2M .


a). Add for every increase of depth of 30cm or part thereof.

C.
D.
E

G.

No

4227.00
893.00
6232.00
1069.00
6779.00
1157.00
8129.00
1337.00
6145.00

30cm depth

1038.00

No
30cm depth

As above of 90 x 60 cm internal size and depth upto 1.2M .

No

a). Add for every increase of depth of 30cm or part thereof.

30cm depth

As above of 90 x 90 cm internal size and depth upto 1.2M .

No

a). Add for every increase of depth of 30cm or part thereof.

30cm depth

As above of 90cminternal dia size & depthupto


1.2 M with precastRCC slab cover
a). Add for everyincrease of depth of30cm or part
thereof.

F.

No
30cm depth

As above of 1.2 x 1.2 M internal size and depth upto 1.2M .

No

a). Add for every increase of depth of 30cm or part thereof.

30cm depth

As above of 1.5 x 1.5M internal size and depth upto 1.5M .

No

a). Add for every increase of depth of 30cm or part thereof.

30cm depth

10922.00
1699.00
15961.00
2100.00

Providing and constructing B.B. masonry valve chamber with 15 cm


thick 1:3:6 proportion PCC bedding, excluding excavation, B.B.
masonry in C.M. 1:5 proportion 12 mm thick cement plaster in cm 1:4
proportion on both sides with providing and fixing C.I. manhole frame
and cover in RCC 1:2:4 coping or RCC 1:2:4 proportion 15 cm thick
slab,etc.complete as directed by Engineer-in-charge.
(Note : Wall thickness : 0.23 M for depth of 1.2 M and 0.35 M for
balance depth exceeding 1.2 M)

Valve Chamber with Cast iron frame & covers.


A.

As above of 60x45 cm internal size and depth upto 0.9 M with 60 x 45


No
cm size CI manhole frame and cover of 40 kg
30cm depth
a). Add for every increase in depth of 30cm or part thereof

B.

As above of 90x45 cm internal size and depth upto 1.2 M with 90 x 45


No
cm size CI manhole frame and cover of 40 kg
30cm depth
a). Add for every increase in depth of 30cm or part thereof

C.

As above of 90x60 cm internal size and depth upto 1.2 M with 90 x 60


No
cm size CI manhole frame and cover of 50 kg
30cm depth
a). Add for every increase in depth of 30cm or part thereof

D.

As above of 90x90 cm internal size and depth upto 1.2 M with 53 cm


dia CI manhole frame and cover of 90 kg fixed in R.C.C. Slab
a). Add for every increase in depth of 30cm or part thereof

E.

As above of 1.2 x 1.2M internal size and depth upto 1.2 M with 53 cm
dia CI manhole frame and cover of 90 kg fixed in R.C.C. Slab
a). Add for every increase in depth of 30cm or part thereof

No
30cm depth

No
30cm depth

7182.00
893.00
9048.00
1069.00
10392.00
1157.00
14694.00
1337.00
16985.00
1699.00

Rate
( in Rs.)
2013-2014

Sr No

Item Description

Unit

F.

As above of 1.5 x 1.5 M internal size and depth upto 1.5 M with 53
cm dia CI manhole frame and cover of 90 kg fixed in R.C.C. Slab

No

a). Add for every increase in depth of 30cm or part thereof

30cm depth

Rate
( in Rs.)
2012-2013

21509.00
2100.00

(Note : Wall thickness : 0.23 M for depth of 1.2 M and 0.35 M for
balance depth exceeding 1.2 M)

Valve Chamber with Precast steel fibre reinforced


concrete ( S.F.R.C.) frame & covers.
A.
B.

As above of 60x45 cm internal size and depth upto 0.9 M .

No

a). Add for every increase in depth of 30cm or part thereof

30cm depth

As above of 90x45 cm internal size and depth upto 1.2 M .

No

a). Add for every increase in depth of 30cm or part thereof

30cm depth

As above of 90x60 cm internal size and depth upto 1.2 M .

No

C.

a). Add for every increase in depth of 30cm or part thereof

30cm depth

As above of 90x90 cm internal size and depth upto 1.2 M .

No

D.

a). Add for every increase in depth of 30cm or part thereof

30cm depth

As above of 1.2 x 1.2M internal size and depth upto 1.2 M with
S.F.R.C. frame and cover of size 540 mm dia fixed in R.C.C. Slab
E.

a). Add for every increase in depth of 30cm or part thereof


As above of 1.5 x 1.5 M internal size and depth upto 1.2 M with
S.F.R.C. frame and cover of size 540 mm dia fixed in R.C.C. Slab

F.

No

30cm depth

No

a).Add for every increase in depth of 30cm or part thereof

2100.00

For single ball air valve

No

b)

For Double ball air valve

No

1935.00
2714.00

Providing and fixing C.I. road box including loading, unloading and
carting to site of work including all necessary excavation in all types
of strata and fixing in murum packing, etc. complete.

a)

100 mm x 225 mm (20 kg)

No

b)

225 mm x 300 mm (40 kg)

No

1700.00
18944.00

Providing and fixing in position M.S. Air valve boxes fabricated with 2 30cm depth
mm thick M.S. plate, 30 x 30 x3 mm size M.S. angle frame, concreting in M-150 for fixing the box in position,applying two coats of oil
paint, painting chainage, locking arrangement, etc. complete as
directed by Engineer-in-charge.

a)

6214.00
893.00
8755.00
1068.00
9518.00
1157.00
11424.00
1337.00
14150.00

Providing and constructing on sewer, B.B. masonry circular manhole


concentric cone 1.2 M dia. at bottom and 0.5 M dia. at top and upto a
depth of 2.00 M with 23 cm brick work in CM 1:4 proportion excluding
excavation including foundation concrete 250 mm thick and
haunches and channels in c.c.1:2:4 proportion, finishing channels in
smooth rendering, providing C.I. dapuri type steps each weighing 5.5
kg., 1:2:4 coping and providing and fixing approved make and quality
S.F.R.C. frame and cover of 56 cm.dia. etc. complete as directed by
Engineer-in-charge.
a)

Rebate for every decrease in depth of 50 cm or part thereof

No

50cm depth

1426.00
2665.00
18014.00

2332.00

Rate
( in Rs.)
2013-2014

Sr No

Item Description

Unit

Providing and constructing on sewer, B.B. masonry circular manhole


concentric cone 1.5 M dia. at bottom and 0.5 M dia. at top and upto a
depth of 5.00 M with 23 cm brick work up to depth of 2 M from top
and 35 cm thick brick work for balance depth in CM 1:4 proportion
with 20 mm thick smooth plaster on both side in cm 1:2 proportion
excluding excavation including foundation concrete 250 mm thick and
haunches and channels in c.c.1:2:4 proportion, finishing channels in
smooth rendering, providing C.I. dapuri type steps each weighting 5.5
kg., 1:2:4 coping and providing and fixing approved make and quality
S.F.R.C. frame and cover of 56 cm.dia. etc. complete as directed by
Engineer-in-charge.

No

Rebate for every decrease in depth of 50 cm or part thereof

50cm depth

Providing and constructing on sewer, B.B. masonry circular manhole


with concentric cone 1.5 M dia. at bottom and 0.5 M dia. at top and
upto a depth of 9.00 M with 23 cm brick work, upto depth of 2 M from
top and 35 cm thick brick work for depth of 2 M and 45 cm thick brick
work for remaining depth upto 9 M in CM 1:4 proporpion with 20 mm
thick smooth plaster on both sides in CM 1:2 proportion excluding
excavation, including foundation concrete 250 mm thick and
haunches and channels in c.c.1:2:4 proportion, finishing channels in
smooth rendering, providing C.I. dapuri type steps each weighing 5.5
kg., 1:2:4 coping and providing and fixing approved make and quality
S.F.R.C. frame and cover of 56 cm.dia. etc. complete as directed by
Engineer-in-charge.

No

a)

a)

A.

Rebate for every decrease in depth of 50 cm or part thereof

1.00 M dia x 2 M Depth


1.00 M dia x 3 M Depth
a).Rebate for every decrease in depth of 50 cm or part thereof

C.

1.00 M dia x 4.5 M Depth


a).Rebate for every decrease in depth of 50 cm or part thereof

D.

1.50 M dia x 2 M Depth


a).Rebate for every decrease in depth of 50 cm or part thereof

E.

1.50 M dia x 3 M Depth


a).Rebate for every decrease in depth of 50 cm or part thereof

F.

48924.00

4849.00
103601.00

6130.00

"Providing and constructing B.B. masonry circular manhole without


conical shape excluding excavation, RCC 1:2:4 proportion, 20 cm
bedding brick masonry in CM 1:4 proportion,23 cm thick for 2 M
depth from top35 cm thick for 2 M below it and 45 cm thick for
balance depth, RCC slab at top and at 2 M depth from top for
supporting brick masonry above it, plastering with smooth finish in
CM 1:2 proportion C.C.1:2:4 finishing channels in smooth rendering,
providing C.I. dapuri type steps each weighing 5.5 kg., providing and
fixing S.F.R.C. frame and cover of 56 cm.dia. at top including cost of
all materials and labour, etc.complete.

a).Rebate for every decrease in depth of 50 cm or part thereof


B.

50cm depth

Rate
( in Rs.)
2012-2013

1.50 M dia x 4.5 M Depth


a).Rebate for every decrease in depth of 50 cm or part thereof
Drainage Drops

No
50cm depth

No
50cm depth

No
50cm depth

No
50cm depth

No
50cm depth

No
50cm depth

15629.00
2226.00
23721.00
3437.00
36503.00
4324.00
24355.00
2972.00
31852.00
4474.00
48440.00
5608.00

Rate
( in Rs.)
2013-2014

Sr No

10

Item Description

Unit

Providing 150 mm dia S.W. or R.C.C.pipes in vertical drop


arrangement including providing 150 mm dia S.W.and R.C.C. pipe
fixed in B.B. masonry of manhole at the required level including
providing 150 mm dia double tee ,150 mm dia right angled bend,
encasing in B.B. masonry 1:4 proportion all around the pipe,double
tee, bend upto the foundation of manhole, jointing, cutting, filleting
including neat cement rendering, plugging the opening with jungle
wood knob complete as directed by Engineer-in-charge (0.60M
depth) excluding cost of chamber.

No

1792.00

50cm depth

610.00
2346.00
730.00
2796.00
907.00
3396.00
988.00
4768.00
1461.00
6454.00
1778.00
8396.00
1961.00

a). Extra for every 0.5 M depth beyond initial depth of o.60 M

11

As above but for 200 mm dia. Pipes & depth 0.60 M


a). Extra for every 0.5 M depth beyond initial depth of o.60 M

12

As above but for 250 mm dia. Pipes & depth 0.60 M


a). Extra for every 0.5 M depth beyond initial depth of o.60 M

13

As above but for 300 mm dia. Pipes & depth 0.60 M


a). Extra for every 0.5 M depth beyond initial depth of o.60 M

14

As above but for 400 mm dia. Pipes & depth 0.60 M


a). Extra for every 0.5 M depth beyond initial depth of o.60 M

15

As above but for 500 mm dia. Pipes & depth 0.60 M


a). Extra for every 0.5 M depth beyond initial depth of o.60 M

16

As above but for 600 mm dia. Pipes & depth 0.60 M


a). Extra for every 0.5 M depth beyond initial depth of o.60 M

17

a)
b)

Providing and fixing in position steel fibre reinforced concrete


(S.F.R.C.) frame and covers of approved make including loading,
unloading, transportation, all taxes, etc. complete as directed by
Engineer-in-charge (20 tonnes capacity)
540 mm dia
560 mm dia

No
50cm depth

No
50cm depth

No
50cm depth

No
50cm depth

No
50cm depth

No
50cm depth

No
No

c)

90 x 45 cm size

No

d)

90 x 60 cm size

No

e)

60 x 60 cm size

No

f)

60 x 45 cm size

No

Rate
( in Rs.)
2012-2013

2632.00
3271.00
2632.00
2853.00
2606.00
2258.00

Rate
( in Rs.)
2013-2014

Section - I(XXI) : Well Sinking and River Infiltration Works


Sr No

Item Description

Unit

Providing, constructing coffer dam in river basin / dam storages as per


type design including excavation, filling the middle portion with B. C.
soil (in gunny bags if required). Providing impervious / semipervious
materials on both side of B.C. soil (in gunny bags if required) including
ramming, compacting to the satisfaction of Engneer-in-charge, till the
completion of work including dismantling coffer dam after completion
of works and disposing off the material as directed by the Engineer-incharge.

Cu.m

Rate
( in Rs.)
2012-2013

499.00

Note: Pay line maximum - Top width payble shall be 2 mtr. and
maximum payble side slopes shall be 1.5 Horizontal to
1
Vertical, if the constructed top width of the side slopes are less, then
the measurements at actual are payble. Extra top width or flatter
slopes are not payble. Contractor is free to use ballies, plastic sheets,
piles, pipes, C.G.I. sheets for supporting hearting materials instead of
impervious/ semipervious hearting materials for which no extra
payments shall be payble. 30% payment shall be withheld for
dismentaling of coffer dam. this foot note shall appear in tender
condition. ( Type section is shown on last page of type design section
of CSR. )

Providing and fabricating at work shop, carting to site of work,


including transport, loading, unloading, hoisting, lowering and setting
out at actual site of well, sinking M.S. plate cutting edge. for R.C.C.
well curb consisiting of 350 mm M.S. plate, 10 mm thick, champhering
at bottom. Cutting edge should be provided in pieces not less than 2
M in length. Each joint should be plain from outside and jointed by
gusset plate 400 x 200 x 12 mm thick M. S. plate with 12 nos. of 20
mm dia. crushank headed bolts (gusset plates from inside) with
unequal angle of 90 x 60 x 10 mm should be welded from top of
chamfered portion at 14mm from bottom so that 15mm side should be
in contact with cutting edge with overlap of 300 mm joints. 16 mm dia
bar should be welded to M.S. plate 200 mm below the top surface and
length should be 1.8 M above plate with a bend 300 mm from plate
surface including 3 coats of anticorrosive paint as directed by
Engineer-in-chage.

Kg

Providing and filling puddle (selected good impervious clay) in


Kolhapur type weirs in proper layers of 15 cm including watering,
ramming and compaction, etc. complete with all leads and lifts.

Cu.m

229

Providing and filling around the well boulders filling of selected variety
and size of boulders including cost of all materials, labour,
transportation, etc. complete with all leads and lifts.

Cu.m

683.00

Providing, and fixing 80 mm dia A.C./P.V.C. pipe weep holes at 1.5 M


c/c staggered including cost of all materials and labour involved with
all leads and lifts.etc. complete with all leads and lifts.

RMT

175.00

Providing and fixing M.S. chaquerred plate flooring of following


thickness supported on M.S.angles (25 x 25 x 5 mm size) including
welding, cutting and fabricating the plate to the required square or
rounding shape, making holes in the plate, including providing and
applying 3 coats of anticorrosive paint, etc. complete as directed by
Engineer-in-charge.

82.00

Rate
( in Rs.)
2013-2014

Sr No

Item Description

Unit

a)

6 mm thick

Sq.m

b)

8 mm thick

Sq.m

Providing at site of works ISI standard RCC slotted pipes of NP-3


class including cost of all central and local taxes, octroi, inspection,
transportation, etc. complete including cost of RCC collar, etc.
complete.
a)
450 mm dia

RMT

b)

RMT

600 mm dia

Rate
( in Rs.)
2012-2013

3623.00
4633.00

3294.00
5108.00

Lowering, laying and jointing RCC slotted pipes of following diameters


including all leads and lifts, cost of jointing material, labour, etc.
complete as directed by Engineer-in-charge.
a)

450 mm dia

RMT

b)

600 mm dia

RMT

178.00
238.00

Providing, lowering, laying and placing in position, shrouding material


for porous pipe gallery / slotted pipe gallery/ trench gallery with all
leads and lifts involved including transportation of materials to site of
works, screening and washing of materials and placing in position with
given section, etc. complete as directed by Engineer-in-charge.
a)

40 mm pebbles

Cu.m

b)

12 mm to 20 mm pebbles

Cu.m

c)

6 mm to 12 mm pebbles

Cu.m

d)

Sand less than 6 mm

Cu.m

1129.00
1366.00
1557.00
772.00

Providing and fixing in position C.I. Type dapuri steps of 22 mm dia.


M.S. bar step with proper anchorage, etc. and providing and applying
3 coats of ant-corrosive paint, etc complete as directed by Engineer-incharge.
Providing and fixing M.S. sluice gates in position as per detailed
drawing and specification including cost of all materials, labour,
operating pedestal, connecting rod, painting with three coats of anticorrosive paint, etc. complete as directed by Engineer-in-charge.

No

300.00

Kg

91.00

12

Providing and fixing in position C.I. /M.S. rose pieces in intake wells
including cost of all materials and labour, painting with three coats of
anti-corrosive oil paint, etc.complete as directed by Engineer-incharge.
Note : This type of pipe anchorage shall be provided at 30 M centre to
centre on alternate side of pipeline for full width of nalla or river.

Kg

90.00

13

Prvoding and spreading around the well 1 mm thick polyethylene


sheet complete as directed by Engineer-in-charge.

Sq.m

20.35

14

Dewatering charges for estimation purpose for head works in river


basin or dam
a)
Approach channel

RMT

5203.00
69391.00
44681.00
4170.00
208161.00

10

11

b)

Intake well of 3 M dia

No

c)

Inspection well of 2 M dia

No

d)

Connecting main

e)

Jack well of 6 M dia

RMT
No

Rate
( in Rs.)
2013-2014

Sr No

Item Description
f)

Approach Bridge

Unit

Rate
( in Rs.)
2012-2013

RMT

701.00

Lph more than 25,000

Day

Lph less than 25,000

Day

2720.00
2705.00

NOTE:1. The contractor at his request may be allowed to start construction


of masonary staining so as not to allow silting of well in coming
mansoon and while paying masonary 25% amount shall be witheheld
and released only when excavation to the full depth is completed.
2. Dewatering :- Total dewatering charges are to be proposed in the
tender as lump sum amount and 75% is payble for excavation and
25% is payble for construction of well/ gallery out of 75% excavation ,
breakup shall be as under
25% for last 1 M depth
20% for 2 M depth which just above last 1 M depth
15% for 2 M depth which just above last 3 M depth
15% for the rest of depth from water table level
3. The provision made for dewatering in the tender being on
lumpsum basis the same shall have reduced / increased
proporpotionatly as the lenght of approach channel , connecting main
or approach bridge reduced/ increased during actual exeuction

15

Condition No.1 and 2 shall appear in tender condition


Carrying out recuperation / yeild test for ascerting the discharge of
constructed well / excavated profile as direrted by Engineer in
charge.The test carried out by drawing down water from the well/
profile below normal / subsoil water level upto full depth rise in water
level is recorded. The normal water level / subsoil water level in the
well / profile as well as strainer / suction level at pump as per design of
W.S. scheme shall be recorded prior. to the test including cost of all
materials.overhead,labours
etc.
completed
as
directed.
The test shall be carried out as per technical circular No.2597 dt.
20/11/97 and shall be carried out for 7 days.

Rate
( in Rs.)
2013-2014

Section -J - Ancillary items for Reservoirs


Sr No

Item Description

Providing and fixing in position copper lightening conductor including


copper rod of 20 mm dia as per upper terminal 1.5 M long with a
knob at end and with conical spike at top, copper tape conductor 20 x
3 mm size, copper earth plate of 3 mm thick and 0.81 sqm. in area,
clamps at 1 M centre to centre including, necessary excavation,
laying and fixing the conductor, providing and fixing 40 mm G.I pipe
upto 3 M height from ground and 0.5 M below ground including
making all connections, filling the earthing pit with charcoal, salt, etc.
and refilling and watering, etc. complete as per specifications laid
down in relevent I.S. codes.
i)

i)

For Tape of 10M length

ii)
Rebate / Extra rate per metre length or part thereof over and
above initial length of 10M
Providing and fixing in position copper lightening conductor including
copper rod of 20 mm dia as per upper terminal 1.5M long with a knob
at end and with conical spike at top, aluminium tape conductor 20 x 3
mm size copper earth plate of 3 mm thick and 0.81 sqm. in area,
clamps at 1 M centre to centre including, necessary excavation,
laying and fixing the conductor, providing & fixing 40 mm G.I pipe
upto 3 M height from ground and 0.5 M below ground including
making all connections, filling the earthing pit with charcoal, salt, etc.
and refilling and watering, etc. complete as per specifications laid
down in relevent I.S. codes.
For Tape of 10M length

Unit

No
Mtr

No

Rate
( in Rs.)
2012-2013

10464.00
276.00

Mtr

9331.00
117.00

No

1725.00

Providing, hoisting and fixing in position C.I. manhole, frame and


cover of best quality and of required size and shape with locking
arrangements including applying 2 coats of anti-corrosive paint, etc.
complete
i)
90 x 60 cm size and weight 35 kg

No

ii)

Kg

2660.00
76.00

RMT

1400.00

571.00
642.00

ii)
Rebate / Extra rate per metre length or part thereof over and
above initial length of 10M
Providing, hoisting and fixing in position inverted J type 100 mm dia.
C.I. cowl type ventilators with mosquitoproof aluminium mesh at top
including applying 2 coats of anti-corrosive paint, etc. complete as
directed by Engineer-in-charge, weighing not less than 35 kg.

Rate on weight basis for any size and type of frame and cover

Providing and fixing in position M.S. ladder 0.50 M wide consisting of


75 x 10 mm M.S. flats as stringers and 16 mm dia M.S. bars in
double rows as steps placed at 25 cm c/c including cost of material
and labour involved, welding, anchoring and applying 3 coat of anticorrosive paint, etc. complete as directed by Engineer-in-charge.

Providing and applying epoxy paint of approved make (Shalimar,


Ciba or Mahindra & Mahindra) to concrete surface of RCC ESR or
GSR or any other structure including cleaning the surface by
scrapping and air blowers to the satisfaction of Engineer-in-charge,
necessary scaffolding, etc complete with all leads and lifts and giving
satisfactory hydraulic test for water tightness as per I.S. codes
a)

For new surfaces - Two coats.

Sq.m

b)

For old surfaces - Two coats.

Sq.m

Rate
( in Rs.)
2013-2014

Sr No

Item Description

Unit

Providing and constructing RCC spiral staircase in M-150 mix


concrete at site of work and consisting of central vertical column of
400 mm dia and steps in RCC M-150, tie members at each brace
level, RCC parapet wall 80 cm high including cost of all labour and
material involved, cost of scaffolding, centering, shuttering, curing,
finishing in CM 1:3 proportion including RCC M-150 footing
foundation, its excavation, refilling and cleaning the site, etc.
complete as per type design, with 3 coats of cement paint.

RMT

Providing and constructing RCC ventilating shaft of diameters and


height mentioned below with required number of RCC 15 x 15 cm
size columns and RCC circular slab or dome over the pillars in M-150
including cost of all material and labour, providing and fixing steel or
wooden frame & providing & fixing G.I. flyproof mesh of 26 gauge
and providing and applying in 3 coats of oil paint to wooden or steel
frame and cement paint to concrete structure. etc. complete as
directed by Engineer-in-charge.

10

i)

0.9 M dia x 1.35 M height

No

ii)

1.2 M dia x 1.80 M height

No

iii)

1.5 M dia x 2.25 M height

Rate
( in Rs.)
2012-2013

6415.00

Providing and installing mercury water level indicator for RCC ESR
and wash water tank site as per instructions of Engneer-in-charge at
ground level of the tank or nearing pump house or room for RCC
ESR having 15 mtrs. staging height and 5 mtrs. water storage height
with indication of water height in storage tank in metre and 1/10th of
meter including providing and installing 15 mm dia class B G.I.
piping with necessary accessories from bottom of the tank upto the
instrument as per instructions of Engineer-in-charge.

No

6882.00
8748.00
13997.00
16872.00

For Extra stage height over 15M or part thereof and water depth
over 5 M or part thereof
Providing and Erecting, installing and commissioning Barometric Leg
Chlorination system for water treatment plant upto 5 MLD. capacity
as per manufacturers specifications with all required materials viz. 15
Kg. pressure yellow PVC pipe, specially prepared chamber, mixing
chamber, scrubber unit, gas pressure flexible pipe, brass nozzle
nipple, electronic alarm unit, PPM dose, indicator of 25 mm dia. 4mm
thick glass tube (Borosil), gas ubit opening spanner 3 hole type,
instruction board, aluminium pipe upto sump ( Maximum length 15
Mtr.) etc. including civil works wherever required for above material
fittings, including satisfactory test and trial at work site etc. complete.
( Item do not include construction of chlorine Gas Room of 3.0 x 3.0
Mtr. or adequate size).

Mtr

907.00

i)

For 5 MLD Capacity

ii)

Add/Deduct per MLD or part of per MLD capacity.

No

1No. per
unit
per MLD

100000.00

11

Providing and fixing water level indicator upto 5 M height including


M.S. enamelled gauge plate 300 mm wide 3 mm thick, P.V.C. float,
providing and fixing required accessories such as pointer, pulleys,
nylon thread including cost of all material, labour, etc. complete.

No

3500.00
8678.00

12

Providing and fixing water level indicator upto 5 M height including


M.S. enamelled gauge plate 150 mm wide 3 mm thick, P.V.C.float,
providing and fixing required accessories such as pointer, pulleys,
nylon thread including cost of all material, labour, etc. complete.

No

5249.00

Rate
( in Rs.)
2013-2014

Section - K - Trial Run


Sr No

Item Description

Commisioning running and maintaining the scheme to quantites, rated


capacity, including manning necessary personnel such as operator,
valveman, etc. as per requirements of the scheme and who should
also administer chemical dose for a period of 1 month for individual
scheme and 3 months for regional scheme, together with training of
personnel spared by MJP/ Local Body and handing over the scheme
to Local Body after completion of the above period as directed by
Engineer-in-charge.
Note. : Required chemicals to be supplied by Department free of cost
and electricity bill will also be paid by the Depertment.
a) For single village ( 3 months)

Unit

Job

Rate
Rate
( in Rs.)
2012- ( in Rs.)
2013
2013-2014

b) For regional scheme upto 3 villages with raw water pumping, one
treatment plant with pumps, raw water pumping main, leading main,
ESR, BPT and distribution system etc.
( 6 months)

Job

48572.00
201115.00

c) For regional scheme upto 3 villages with raw water pumping, one
treatment plant with pumps, raw water pumping main, leading main,
ESR, BPT and distribution system etc. ( 6 months) (Without WPT).

Job

130081.00

d) For regional schemes more than 3 villages, trial period shall be


one year with raw water pumping , one treatment plant with
pumps,raw water pumping main, leading main,ESR, BPT and
distribution system etc. ( for One year)
e) For regional schemes more than 3 villages, trial period shall be
one year with raw water pumping , pumps , raw water pumping
main, leading main,ESR, BPT and distribution system etc. ( Without
WTP) ( for One year )
f) Add for every additional village

Job

407997.00

Job

264105.00

Month

g) Add for every pumping station.

Month

5996.00
9867.00

Section - I- ( I )- C.I./D.I.Pipes
Sr
No

Item Description

Unit Rate ( in Rs.)


2013
With ED

2012-

Without ED

Providing and supplying ISI mark C.I. S&S pipes (push on joints
pressure pipes of C.I.of following class and diameters confirming to
the I.S. specification inclusive cost of jointing materials (Rubber
gasket of EPDM Quality) including all statutory duties and taxes levied
by GoI and GoM in all respect, Education cess,VAT, Third party
inspection charges of TPI Agency approved by MJP including Transit
insurance, Railway freight unloading from railway wagon, loading into
trucks, transportation to departmental stores / site of work, unloading
stacking etc. completed as directed by Engineer- incharge(IS:1536/2001 for pipes and IS 158/1969 and IS 12820/1989 or
latest edition/ revision with amendments for Rubber Gasskets.

CLASS " LA "

a
1

Class "LA" - 80mm

RMT

Class "LA" - 100 mm

RMT

Class "LA" - 125 mm

RMT

Class "LA" - 150 mm

RMT

Class "LA" - 200 mm

RMT

Class "LA" - 250 mm

RMT

Class "LA" - 300 mm

RMT

Class "LA" - 350 mm

RMT

Class "LA" - 400 mm

RMT

10

Class "LA" - 450mm

RMT

11

Class "LA" - 500 mm

RMT

12

Class "LA" - 600 mm

RMT

13

Class "LA" - 700 mm

RMT

14

Class "LA" - 750 mm

RMT

15

Class "LA" - 800 mm

RMT

16

Class "LA" - 900 mm

RMT

17

Class "LA" - 1000 mm

RMT

900
1128
1425
1831
2636
3555
4594
4537
5522
6658
7696
10253
13232
14820
16589
20206
24274

844
1058
1270
1718
2484
3348
4317
3948
4806
5794
6698
8921
11514
12897
14435
17582
21122

956
1193
1552
1912
2763
3735
4833
6043
7410
8976
10292
13744
17911

852
1063
1383
1703
2461
3327
4306
5384
6602
7998
9170
12245
15958

CLASS " A "

b
1

Class "A" - 80 mm

RMT

Class "A" - 100 mm

RMT

Class "A" - 125 mm

RMT

Class "A" - 150 mm

RMT

Class "A" - 200 mm

RMT

Class "A" - 250 mm

RMT

Class "A" - 300 mm

RMT

Class "A" - 350 mm

RMT

Class "A" - 400 mm

RMT

10

Class "A" - 450 mm

RMT

11

Class "A" - 500 mm

RMT

12

Class "A" - 600 mm

RMT

13

Class "A" - 700 mm

RMT

Sr
No

Item Description

Unit Rate ( in Rs.)


2013
With ED

14

Class "A" - 750 mm

RMT

15

Class "A" - 800 mm

RMT

16

Class "A" - 900 mm

RMT

17

Class "A" - 1000 mm

RMT

Without ED

19896
22241
27072
32562

17725
19815
24119
29010

1016
1272
1670
2058
2987
4039
5237
6554
7567
9689
11136
14671
19165
21583
24058
29330
35189

905
1134
1489
1834
2661
3598
4666
5840
6742
8631
9921
13070
17085
19229
21435
26132
31352

CLASS " B "

c
1

Class "B" - 80 mm

RMT

Class "B" - 100 mm

RMT

Class "B" - 125 mm

RMT

Class "B" - 150 mm

RMT

Class "B" - 200 mm

RMT

Class "B" - 250 mm

RMT

Class "B" - 300 mm

RMT

Class "B" - 350 mm

RMT

Class "B" - 400 mm

RMT

10

Class "B" - 450 mm

RMT

11

Class "B" - 500 mm

RMT

12

Class "B" - 600 mm

RMT

13

Class "B" - 700 mm

RMT

14

Class "B" - 750 mm

RMT

15

Class "B" - 800 mm

RMT

16

Class "B" - 900 mm

RMT

17

Class "B" - 1000 mm

RMT

2012-

Lowering laying and jointing with SBR ruber gaskets C.I. S/S pipes of
various classes with CI / MS specials of following diameter in proper
position, grade and alignment as directed by Engineer-in-charge
including conveyance of material from stores to site of work, including
cost of jointing materials and rubber rings labour, giving hydraulic
testing etc. complete.

Without
Rubber Ring

Note : Only S.B.R. Rubber gasket to be used as per IS 5382 and IS


12820
C.I. "LA"CLASS / D.I.-K-9/K-7 Mortar Lined

80 mm

RMT

100 mm

RMT

125 mm

RMT

150 mm

RMT

200 mm

RMT

250 mm

RMT

300 mm

RMT

350 mm

RMT

400 mm

RMT

10

450 mm

RMT

11

500 mm

RMT

44
53
66
70
94
123
133
166
199
199
230

With
Rubber
Ring

50
59
73
79
104
135
152
186
230
243
280

Sr
No

Item Description

Unit Rate ( in Rs.)


2013
With ED

12

600 mm

RMT

13

700 mm

RMT

14

750 mm

RMT

15

800 mm

RMT

16

900 mm

RMT

17

1000 mm

RMT

2012-

Without ED

303
390
437
535
639
756

373
525
574
674
846
1026

46
56
71
78
102
133
145
179
201
211
249
329
423
475
561
676
789

56
66
79
86
110
146
163
200
231
245
298
398
556
610
698
882
1058

50
60
77
87
110
144
157
193
225
228
268
355
457
516
602
714
814

59
71
86
96
124
164
175
225
255
262
316
423
588
650
737
918
1082

C.I. "A"CLASS

b
1

80 mm

RMT

100 mm

RMT

125 mm

RMT

150 mm

RMT

200 mm

RMT

250 mm

RMT

300 mm

RMT

350 mm

RMT

400 mm

RMT

10

450 mm

RMT

11

500 mm

RMT

12

600 mm

RMT

13

700 mm

RMT

14

750 mm

RMT

15

800 mm

RMT

16

900 mm

RMT

17

1000 mm

RMT
C.I. "B"CLASS

c
1

80 mm

RMT

100 mm

RMT

125 mm

RMT

150 mm

RMT

200 mm

RMT

250 mm

RMT

300 mm

RMT

350 mm

RMT

400 mm

RMT

10

450 mm

RMT

11

500 mm

RMT

12

600 mm

RMT

13

700 mm

RMT

14

750 mm

RMT

15

800 mm

RMT

16

900 mm

RMT

17

1000 mm

RMT

NOTE : Only 85% rate shall be payble till satiafactory hydraulic testing is given.

Sr
No

Item Description

Providing and supplying ISI mark D.I. S&S pipes (push on joints
pressure pipes of D.I.of following class and diameters confirming to
the I.S. specification inclusive cost of jointing materials (Rubber
gasket of EPDM Quality) including all statutory duties and taxes levied
by GoI and GoM in all respect, Education cess,VAT, Third party
inspection charges of TPI Agency approved by MJP including Transit
insurance, Railway freight unloading from railway wagon, loading into
trucks, transportation to departmental stores / site of work, unloading
stacking etc. completed as directed by Engineer- incharge(IS:8329/2000 for pipes and IS 158/1969 and IS 12820/1989 or
latest edition/ revision with amendments for Rubber Gasskets.

D.I. K - 9

Unit Rate ( in Rs.)


2013

100 mm

RMT

150 mm

RMT

200 mm

RMT

250 mm

RMT

300 mm

RMT

350 mm

RMT

400 mm

RMT

450 mm

RMT

500 mm

RMT

10

600 mm

RMT

11

700 mm

RMT

12

750 mm

RMT

13

800 mm

RMT

14

900 mm

RMT

1000 mm

RMT

15

2012-

With ED

Without ED

With ED

Without
ED

1145
1670
2076
2768
3519
4405
5208
6288
7308
9664
12403
14102
15339
18933
22098

1041
1518
1888
2516
3200
4010
4730
5716
6644
8773
11276
12819
13949
17212
20089

977
1434
1692
2242
2826
3480
4143
5000
5859
7717
10409
12097
13989
16779
19646

888
1304
1538
2038
2569
3164
3766
4545
5326
7015
9463
10997
12717
15264
17860

D.I. K-7

100 mm

RMT

150 mm

RMT

200 mm

RMT

250 mm

RMT

300 mm

RMT

350 mm

RMT

400 mm

RMT

450 mm

RMT

500 mm

RMT

10

600 mm

RMT

11

700 mm

RMT

12

750 mm

RMT

13

800 mm

RMT

14

900 mm

RMT

15

1000 mm

RMT

Sr
No

Item Description

Unit Rate ( in Rs.)


2013
With ED

2012-

Without ED

NOTE : 1) D.I. K-7 pipes shall not be used for Distribution System for dia. Less than & including 250mm.
NOTE : 2)For lowering laying & jointing D.I. K-9 / K-7 pipes rates shall be adopted as per C.I."LA" Class pipe.

4
1

Providing and making lead caulked joint with molten lead to Cast Iron
pipes and / or specials of all classes and fitting of following dia
including cost of lead and all jointing material, labour, hydraulic testing
etc. complete.
80 mm
Joint

100 mm

Joint

125 mm

Joint

150 mm

Joint

200 mm

Joint

250 mm

Joint

300 mm

Joint

350 mm

Joint

400 mm

Joint

10

450 mm

Joint

11

500 mm

Joint

12

600 mm

Joint

13

700 mm

Joint

14

750 mm

Joint

15

800 mm

Joint

16

900 mm

Joint

17

1000 mm

Joint

657
812
968
1200
1750
2126
2564
2906
3389
4707
5060
6501
7637
8675
9316
9936
10594

NOTE : Only 85% payment shall be payble till satiafactory hydraulic testing is given.

Providing and supplying ISI standard CI double flanged pipes


including all taxes (Central and local), railway freight, insurance,
unloading from railway wagon, loading into truck transport to stores /
site, unloading etc. complete as directed by Engneer-in-charge.

80 mm

RMT

100 mm

RMT

125 mm

RMT

150 mm

RMT

200 mm

RMT

250 mm

RMT

300 mm

RMT

350 mm

RMT

400 mm

RMT

10

450 mm

RMT

11

500 mm

RMT

12

600 mm

RMT

13

700 mm

RMT

14

750 mm

RMT

1419
1753
2284
2849
4371
5890
7573
9885
12053
14473
16986
24162
32371
35221

Sr
No

Item Description

Unit Rate ( in Rs.)


2013
With ED

Providing and supplying ISI standard CI flanged / S& S specials


including all taxes (Central and local), railway freight, insurance,
unloading from railway wagon, loading into truck transport to
depermental store/ site, unloading stacking etc. complete.

D/F Specials

D/F Specials Upto and including 300 mm dia.

KG

D/F Specials Above 350 mm dia upto 600 mm

KG

Above 600 mm Dia

KG

S/S Specials / Socketted Br.Flagd. Specials

S/S Specials/ socketed Branch Flanged Specials Upto and including KG


300 mm dia.
S/S Specials/ socketed Branch Flanged Specials from 350 mm To KG
600 mm dia.
Above 600 mm dia.
Kg

2
3

73.60
78.20
83.90
71.30
75.90
80.50

Plain ended / P.E. Br.Flagd. Specials

Upto and including 300 mm dia.

KG

from 350 mm To 600 mm dia.

KG

Above 600 mm dia.

Kg

Providing and supplying ISI standard MS specials of required


thickness with 3 coats of approved make epoxy paint (Shalimar, Ciba
or Mahindra & Mahindra make) from inside and outside including all
taxes (Central and local), octroi, inspection charges, transportation to
stores / site, and stacking, etc. complete.

Machine ends suitable for PSC pipes of all diameters as per KG


detailed drawing with 10 mm thick x 0.7 M long barrel welded to it.

76.50

Only flanges with machining and drilling holes, etc. complete more KG
than 40 mm thick
Double flanged specials of all diameters
KG

74.30

3
4
5
6

All socketted specials or socketted branch flanged specials of all KG


diameters
Plain ended specials or plain ended branch flanged specials of all KG
diameters
MS barrels (pipe pieces) locally manufactured (for small KG
quantities)
Providing and making flanged joints to flanged C.I./M.S. pipes of all
classes/specials etc. including cost of all jointing materials (rubber
packing, nut bolts, etc.), labour, hydraulic testing etc. complete.

80 mm

Joint

100 mm

Joint

125 mm

Joint

150 mm

Joint

200 mm

Joint

250 mm

Joint

300 mm

Joint

350 mm

Joint

400 mm

Joint

10

450 mm

Joint

69.00
75.90
80.50

72.10
72.10
72.10
70.00

174
301
314
603
626
897
931
1213
1511
1848

2012-

Without ED

Sr
No

Item Description

Unit Rate ( in Rs.)


2013
With ED

11

500 mm

Joint

12

600 mm

Joint

13

700 mm

Joint

14

750 mm

Joint

15

800 mm

Joint

16

900 mm

Joint

17

1000 mm

Joint

1912
2052
3093
3179
4398
4560
4721

NOTE : Only 85% payment shall be payble till satiafactory hydraulic testing is given.
and hoisting in position and jointing, testing M.S./ C.I. D/F
9 Erecting
pipes and specials in vertical position including cost of all jointing
materials (rubber packing, nut bolts, etc.) labour, scaffolding,
hydraulic testing etc. complete.
1

80 mm

Joint

100 mm

Joint

125 mm

Joint

150 mm

Joint

200 mm

Joint

250 mm

Joint

300 mm

Joint

350 mm

Joint

400 mm

Joint

10

450 mm

Joint

11

500 mm

Joint

12

600 mm

Joint

13

700 mm

Joint

14

750 mm

Joint

800 mm
900 mm
1000 mm

Joint

15
16
17

Joint
Joint

193
326
344
640
680
970
1025
1331
1655
2022
2115
2323
3445
3576
4843
5098
5373

NOTE : Only 85% payment shall be payble till satiafactory hydraulic testing is given.

10

Providing and supplying ISI standard D.I. specials & fittings with
sealing rubber gasket of S.B.R.,complete with Cast iron follower gland
and M.S. nut & bolts coated or otherwise protected from rusting and
suitable for D.I. pipes including cost of all labours and materials and
transportation to stores / site, loading , unloading including all taxes ,
etc. complete.As per IS 9523
For all types of specials , bends,tees etc.

a
b

11

80 to 300 mm dia.

Kg.

350 mm & above dia.

Kg.

Providing and supplying ISI standard welded DI double flanged


pipe including all taxes (central & local) railway freight,
insurance, unloading from railway wagon, loading into truck
transport to store / site, unloading, stacking etc. complete as
directed by Engineer -in- cahrge. (for 2.75 m bare pipe)

107.00
130.00

2012-

Without ED

Sr
No

Item Description

Unit Rate ( in Rs.)


2013
With ED

i)
ii)
iii)
iv)
v)
vi)
vii)
viii)
ix)
x)
xi)
xii)
xiii)
xiv)

100 mm
150 mm
200 mm
250 mm
300 mm
350 mm
400 mm
450 mm
500 mm
600 mm
700 mm
800 mm
900 mm
1000 mm

RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT

1863
2530
3238
4394
5531
7203
8720
10419
12110
15946
21457
26228
32555
38225

2012-

Without ED

Section - I - ( ii )A.C.Pipes
Sr No

Item Description

Providing and supplying Asbestos Cement pressure pipes


manufactured and tested as per ISO-160 standards of following class
and diameter in standard lengths including cost of all taxes (Central
and local) insurance, railway fright, inspection charges, unloading
from railway wagon, loading into truck, transporting to departmental
stores / site, unloading, stacking, etc. complete.

Class - 15 ( Test Pressure - 1.5 Mpa.)

1
2

80 mm
100 mm
125 mm
150 mm
200 mm
250 mm
300 mm

Class - 20 ( Test Pressure - 2.0 Mpa.)

1
2

80 mm
100 mm
125 mm
150 mm
200 mm
250 mm
300 mm

Class - 25 ( Test Pressure - 2.5 Mpa.)

1
2

80 mm
100 mm
125 mm
150 mm
200 mm
250 mm
300 mm

3
4
5
6

3
4
5
6

3
4
5
6
7

Unit

Rate ( in Rs.)
2012-2013
With ED

RMT
RMT
RMT
RMT

139
179
214
376

RMT
RMT
RMT
RMT
RMT
RMT
RMT

139
208
244
431
612
906
1119

190
317
367
658

173
288
334
598
789
1184
1298

RMT
RMT

RMT
RMT
RMT
RMT
RMT
RMT

Providing and supplying C.I. detachable joints suitable for A.C.


pressure pipes manufactured as per ISO-160 standards of following
class and diameter including cost of all taxes (Central and local),
insurance, railway freight, inspection charges, unloading from railway
wagon, loading into truck, transporting to departmental store / site,
unloading, stacking and cost of rubber rings, nut bolts, etc. complete.
( IS 1538/1993 )
Class - 15 ( Test Pressure - 1.5 Mpa.)

1
2

80 mm

No

100 mm

No

125 mm

No

150 mm

No

200 mm

No

250 mm

No

300 mm

No

126
162
194
341
497
719
1052

153
229
269
475

RMT

RMT

Without ED

300
380
510
636
960
1204
1650

Sr No

Item Description

Unit

Class - 20 ( Test Pressure - 2.0 Mpa.)

b
1
2

80 mm

No

100 mm

No

125 mm

No

150 mm

No

200 mm

No

250 mm

No

300 mm

No

Providing and supplying A. C. pressure coupler suitable for A.C.


pressure pipes manufactured as per ISO-160 standards of following
class and diameter including cost of all taxes (Central and local)
insurance, railway fright, inspection charges, and cost of rubber rings,
etc. complete. (supply at stores / site).

1
2

80 mm

No

100 mm

No

125 mm

No

150 mm

No

39
50
69
84

Class - 20 ( Test Pressure - 2.0 Mpa.)

b
1
2

80 mm

No

100 mm

No

125 mm

No

150 mm

No

42
56
72
98

Lowering, laying and jointing with C.I.D. joints, A. C. pressure pipes


and C.I. or M. S. specials of following class and diameters including
conveyance from stores to site of works, cost of labour and material,
giving satisfactory hydraulic testing, etc. as per IS code, etc. complete
(excluding cost of C. I. D. joints nut bolts, rubber rings.)
Class - 15 ( Test Pressure - 1.5 Mpa.)

1
2

80 mm

RMT

100 mm

RMT

125 mm

RMT

150 mm

RMT

200 mm

RMT

250 mm

RMT

300 mm

RMT

325
425
550
659
886
1250
1790

Class - 15 ( Test Pressure - 1.5 Mpa.)

Rate ( in Rs.)
2012-2013

31
43
46
57
73
92
113

Class - 20 ( Test Pressure - 2.0 Mpa.)

1
2

80 mm

RMT

100 mm

RMT

125 mm

RMT

150 mm

RMT

200 mm

RMT

250 mm

RMT

300 mm

RMT

32
46
50
63
83
104
129

Sr No

Item Description

Unit

Lowering laying and jointitng with A. C. coupler A.C. pressure pipes


and C.I. or M.S. specials of following class and diameters including
conveyance from stores to site of works, cost of labour and material,
giving satisfactory hydraulic testing, etc. as per IS code, etc. complete
excluding cost of A. C. couplers and rubber rings.

Class - 15 ( Test Pressure - 1.5 Mpa.)

1
2

80 mm

RMT

100 mm

RMT

125 mm

RMT

150 mm

RMT

200 mm

RMT

250 mm

RMT

300 mm

RMT

Rate ( in Rs.)
2012-2013

21
28
33
42
58
74
96

Class - 20 ( Test Pressure - 2.0 Mpa.)

1
2

80 mm

RMT

100 mm

RMT

125 mm

RMT

150 mm

RMT

200 mm

RMT

250 mm

RMT

300 mm

RMT

22
33
37
48
69
86
113

NOTE : 1) Only 85% payment for lowering laying jointing shall be payble till satiafactory hydraulic testing is given.
NOTE : 2) Without any extra cost every pipe in the factory shall be hydraulically tested for 1 higher class I.e. when class 15 is
ordered every pipe shall be tested for 20 Kg./Sqcm at factory but pipe shall be branded & paid as class 15. This foot note
shall appear in tender condition.
NOTE : 3) Whenever manufacturer & contractor for lowering laying jointing is separate the principle contractor shall enter into
an aggrement with A.C.pipe manufacturer for satisfactory manufacturing ,transporting ,lowering ,laying jointing & testing of
pipe.This foot Note shall appear in tender conditions

Section - I - ( iii ) - P.V.C.Pipes


Sr No

Item Description

Unit

Rate ( in Rs.)
2012-2013

Providing and supplying in standard lengths ISI mark rigid


unplasticised PVC pipes suitable for potable water with solvent
cement joints including cost of couplers, as per IS specification no.
4985 / 1988 including all local and central taxes, transportation, freight
charges, inspection charges, loading, unloading, conveyance to the
departmental stores / site and stacking the same in closed shed duly
protected from sun rays and rains including cost of jointing material
i.e. solvemt cement, etc. complete (selffit type to be jointed with
cement solvent).

Note ; 1) 10% of cost of pipe shall be considered for cost of P.V.C. specials for estimate purpose only.
Note ; 2) One coupler & required cement solvent shall be provided with each full length pipe, cost of
which is included in rates below.

63 mm

RMT

75 mm

RMT

90 mm

RMT

110 mm

RMT

140 mm

RMT

160 mm

RMT

180 mm

RMT

200 mm

RMT

225 mm

RMT

10

250 mm

RMT

11

280 mm

RMT

12

315 mm

RMT

13

355 mm

RMT

400 mm

RMT

Without
ED

46
65
91
124
208
274
372
460
589
719
953
1213
1626
2074

41
58
81
110
184
243
331
408
522
638
847
1078
1445
1844

66
93
133
185
307
397
528
673
851
1061
1401
1786
2384
3046

58
83
119
164
273
353
469
599
755
944
1244
1587
2118
2706

Working Pressure 4 Kg./Sq.cm

14

With ED

Working Pressure 6 Kg./Sq.cm

63 mm

RMT

75 mm

RMT

90 mm

RMT

110 mm

RMT

140 mm

RMT

160 mm

RMT

180 mm

RMT

200 mm

RMT

225 mm

RMT

10

250 mm

RMT

11

280 mm

RMT

12

315 mm

RMT

13

355 mm

RMT

14

400 mm

RMT

Sr No

Item Description

Unit

Working Pressure 8 Kg./Sq.cm

63 mm

RMT

75 mm

RMT

90 mm

RMT

110 mm

RMT

140 mm

RMT

160 mm

RMT

180 mm

RMT

200 mm

RMT

225 mm

RMT

10

250 mm

RMT

11

280 mm

RMT

12

315 mm

RMT

13

355 mm

RMT

400 mm

RMT

14

91
129
183
257
427
557
740
931
1181
1478
1946
2464
3315
4293

80
114
162
229
379
496
658
827
1050
1313
1729
2191
2945
3814

108
154
223
315
508
666
915
1131
1445
1826
2294
2916
3920
4999

96
138
197
278
452
590
813
1005
1283
1621
2039
2590
3484
4442

138
195
281
399
648
851
1164
1446
1837
2322
2920
3724
4977
6449

123
173
250
354
575
757
1035
1284
1632
2063
2596
3310
4423
5730

. Working Pressure 10 Kg./Sq.cm

63 mm

RMT

75 mm

RMT

90 mm

RMT

110 mm

RMT

140 mm

RMT

160 mm

RMT

180 mm

RMT

200 mm

RMT

225 mm

RMT

10

250 mm

RMT

11

280 mm

RMT

12

315 mm

RMT

13

355 mm

RMT

14

400 mm

RMT

Rate ( in Rs.)
2012-2013

. Working Pressure 12.50 Kg./Sq.cm

63 mm

RMT

75 mm

RMT

90 mm

RMT

110 mm

RMT

140 mm

RMT

160 mm

RMT

180 mm

RMT

200 mm

RMT

225 mm

RMT

10

250 mm

RMT

11

280 mm

RMT

12

315 mm

RMT

13

355 mm

RMT

14

400 mm

RMT

Sr No

Item Description

Unit

Rate ( in Rs.)
2012-2013

Providing and supplying in standard lengths ISI mark rigid


unplasticised PVC pipes for potable water with rubber ring joints
including cost of rubber ring as per IS 4985-1988, all local and central
taxes, transportation. freight charges, transit insurance, inspection
charges, loading, unloading, conveyance to store / site and stacking
the same in closed shed duly protected from sun rays and rains, etc.
complete as directed.( With third party inspection )

Note ; One Rubber Ring shall be provided with each full length pipe, cost of which is included in rates
below.

. Working Pressure 4 Kg./Sq.cm

RMT

63 mm
75 mm
90 mm
110 mm
125 mm
140 mm
160 mm
180 mm

200 mm

RMT

10

225 mm

RMT

11

250 mm

RMT

12

280 mm

RMT

13

315 mm

RMT

. Working Pressure 6 Kg./Sq.cm

2
3
4
5
6
7

RMT
RMT
RMT
RMT
RMT
RMT
RMT

63 mm

RMT

75 mm

RMT

90 mm

RMT

110 mm

RMT

125 mm

RMT

140 mm

RMT

160 mm

RMT

180 mm

RMT

200 mm

RMT

10

225 mm

RMT

11

250 mm

RMT

12

280 mm

RMT

13

315 mm

RMT

48
69
96
131
181
219
291
395
487
623
763
1011
1287

43
60
85
117
161
195
257
350
434
554
678
899
1142

69
98
142
197
271
325
421
560
714
902
1126
1484
1892

61
88
126
173
239
290
373
498
634
800
1001
1319
1682

95
137
193
272
376
454
591
785
988
1252

84
122
171
243
334
402
526
697
877
1113

. Working Pressure 8 Kg./Sq.cm

63 mm

RMT

75 mm

RMT

90 mm

RMT

110 mm

RMT

125 mm

RMT

140 mm

RMT

160 mm

RMT

180 mm

RMT

200 mm

RMT

10

225 mm

RMT

Sr No

Item Description

Unit

11

250 mm

RMT

12

280 mm

RMT

13

315 mm

RMT

1565
2063
2613

1390
1834
2323

114
165
236
333
460
538
705
969
1199
1531
1935
2432
3090

103
146
209
296
406
478
626
862
1065
1360
1720
2161
2746

146
207
297
424
584
687
903
1235
1531
1946
2462
3096
3946

129
183
265
376
518
611
801
1097
1361
1730
2186
2751
3507

. Working Pressure 10 Kg./Sq.cm

d
1

63 mm

RMT

75 mm

RMT

90 mm

RMT

110 mm

RMT

125 mm

RMT

140 mm

RMT

160 mm

RMT

180 mm

RMT

200 mm

RMT

10

225 mm

RMT

11

250 mm

RMT

12

280 mm

RMT

13

315 mm

RMT

. Working Pressure 12.5 Kg./Sq.cm

e
1

63 mm

RMT

75 mm

RMT

90 mm

RMT

110 mm

RMT

125 mm

RMT

140 mm

RMT

160 mm

RMT

180 mm

RMT

200 mm

RMT

10

225 mm

RMT

11

250 mm

RMT

12

280 mm

RMT

13

315 mm

RMT

Rate ( in Rs.)
2012-2013

Lowering, laying and jointing with P.V.C. pipes and specials of


following class and diameter including cost of conveyance from stores
to site of works including cost of all labour, material, except cement
solvent, rubber ring, giving satisfactory hydraulic testing as per IS
code, etc. complete (with cement solvent joint / ring fit joint).
. Working Pressure 4 Kg./Sq.cm

63 mm

RMT

75 mm

RMT

90 mm

RMT

110 mm

RMT

140 mm

RMT

160 mm

RMT

180 mm

RMT

200 mm

RMT

225 mm

RMT

10

250 mm

RMT

16
21
25
29
34
38
42
46
53
57

Sr No

Item Description

Unit

11

280 mm

RMT

12

315 mm

RMT

13

355 mm

RMT

14

400 mm

RMT

Rate ( in Rs.)
2012-2013

63
70
77
84

. Working Pressure 6 to 12.50 Kg./Sq.cm

63 mm

RMT

75 mm

RMT

90 mm

RMT

110 mm

RMT

140 mm

RMT

160 mm

RMT

180 mm

RMT

200 mm

RMT

225 mm

RMT

10

250 mm

RMT

11

280 mm

RMT

12

315 mm

RMT

13

355 mm

RMT

14

400 mm

RMT

22
29
33
37
44
47
53
58
63
69
78
87
96
106

NOTE : 1) Only 85% payment for lowering laying jointing shall be payble till satiafactory hydraulic testing is given.
NOTE : 2) Third party inspecting agency shall invarably carry out Specific gravity Test , Ash Content test and confirm in writing
that those are within prescribed limits. This condition shall appear in tender conditions.
NOTE : 3) After receipt of pipes at site concerned Deputy Engineer shall confirm that weight of pipe for every class and dia is
not less than the prescribed standard weight as per IS 4985/1998 ( Which is given in CSR ) underweight pipes shall be
rejected .This condition shall appear in tender conditions.

Section -I ( IV ) - G.I.Pipes
Sr No

Item Description

Unit

Rate ( in Rs.)
2013

2012-

Providing ISI mark G.I. pipe of following class and dia. Including all
local and central taxes, octroi, inspection charges, transportation to
stores, etc. complete .as per IS 1239/2004

Note ; 2) One coupler shall be provided with each full length pipe, cost of which is included
in rates below.
With ED

LIGHT

15 mm

RMT

20 mm

RMT

25 mm

RMT

32 mm

RMT

40 mm

RMT

50 mm

RMT

65 mm

RMT

80 mm

RMT

100 mm

RMT

71
106
146
183
229
288
397
477
680

65
95
131
166
208
255
349
420
596

85
108
165
209
240
342
424
556
820
1097
1311

77
98
150
189
218
301
384
503
719
978
1151

96
125
196
246
285
395
508
649
936
1159
1396

87
113
177
223
259
359
461
589
849
1052
1266

MEDIUM

15 mm

RMT

20 mm

RMT

25 mm

RMT

32 mm

RMT

40 mm

RMT

50 mm

RMT

65 mm

RMT

80 mm

RMT

100 mm

RMT

10

125 mm

RMT

11

150 mm

RMT

Without
ED

HEAVY

15 mm

RMT

20 mm

RMT

25 mm

RMT

32 mm

RMT

40 mm

RMT

50 mm

RMT

65 mm

RMT

80 mm

RMT

100 mm

RMT

10

125 mm

RMT

11

150 mm

RMT

Sr No

Item Description

Unit

Rate ( in Rs.)
2013

23.00
26.00
32.00
37.00
46.00
55.00
80.00
89.00
106.00

Lowering, laying and jointing G. I. pipes and specials of following


class and diameter including conveyance from stores to site of works,
all labour, giving satisfactory hydraulic test, etc. complete either
underground or in vertical position, as directed by Engineer-in-charge.
LIGHT

15 mm

RMT

20 mm

RMT

25 mm

RMT

32 mm

RMT

40 mm

RMT

50 mm

RMT

65 mm

RMT

80 mm

RMT

100 mm

RMT

MEDIUM

15 mm

RMT

20 mm

RMT

25 mm

RMT

32 mm

RMT

40 mm

RMT

50 mm

RMT

65 mm

RMT

80 mm

RMT

100 mm

RMT

10

125 mm

RMT

11

150 mm

RMT

HEAVY

15 mm

RMT

20 mm

RMT

25 mm

RMT

32 mm

RMT

40 mm

RMT

50 mm

RMT

65 mm

RMT

80 mm

RMT

100 mm

RMT

10

125 mm

RMT

150 mm

RMT

11

25.00
28.00
34.00
39.00
50.00
59.00
86.00
97.00
106.00
113.00
119.00
27.00
30.00
36.00
43.00
54.00
67.00
94.00
113.00
106.00
118.00
128.00

Note : Only 85 % Payment shall be payable till satisfactory hydraulic testing is given

2012-

Section -I ( V ) - S.W.Pipes
Sr No

Item Description

Providing ISI standard Stoneware pipes including all taxes (Central


and local), inspection charges, railway freight, unloading from railway
wagons, loadng into trucks, transport to departmental stores,
unloading, stacking etc. complete.as per IS 651

Unit

Rate
( in Rs.)
2012-2013

122
167
223
269
300
352

100 mm

RMT

150 mm

RMT

200 mm

RMT

225 mm

RMT

250 mm

RMT

300 mm

RMT

Lowering, laying and jointing in proper grade and alignment


Stoneware pipes with cement joints in C. M. (1:1) proportion of
following diameters including cost of conveyance from stores to site of
work jointing material, labour, giving satisfactory hydraulic testing etc.
complete.as per IS 1742
100 mm

RMT

150 mm

RMT

200 mm

RMT

225 mm

RMT

250 mm

RMT

300 mm

RMT

Note : Only 85 % Rate shall be payable till satisfactory hydraulic testing is given

64
105
131
143
156
183

Section - I- ( Vi )- R.C.C.Pipes
Sr No

Item Description

Unit

Rate ( in Rs.) 2012-2013

Collar Joints

Rubber Ring
Joints

With E.D Without With E.D Without


E.D
E.D

Providing ISI standard R.C.C. pipes in standard lengths of following


class and diameter suitable for either collar joints or rubber ring joints,
including all taxes (Central and local), inspection charges, transport to
departmental stores/site, unloading and stacking etc. complete. as
per IS 458/1988

Note ; One Collar shall be supplied with each full length plain
ended R.C.C.pipe, cost including in rates below.One rubber
ring shall be supplied with each full length socketted pipe , cost
including in rates below.
With Third Party Inspection

Class P-I

80 mm

RMT

100 mm

RMT

150 mm

RMT

200 mm

RMT

225 mm

RMT

250 mm

RMT

300 mm

RMT

350 mm

RMT

400 mm

RMT

10

450 mm

RMT

11

500 mm

RMT

12

600 mm

RMT

13

700 mm

RMT

14

800 mm

RMT

15

900 mm

RMT

16

1000 mm

RMT

17

1100 mm

RMT

18

1200 mm

RMT

Class P-II

80 mm

RMT

100 mm

RMT

150 mm

RMT

200 mm

RMT

225 mm

RMT

250 mm

RMT

300 mm

RMT

350 mm

RMT

400 mm

RMT

10

450 mm

RMT

11

500 mm

RMT

12

600 mm

RMT

309
324
339
396
452
494
632
681
864
1064
1280
1615
2103
2428
3056
3580
4068
4887

281
294
309
360
411
449
575
619
785
966
1163
1466
1910
2205
2775
3252
3694
4438

273
293
304
355
407
443
567
613
782
962
1153
1456
1892
2184
2751
3225
3662
4402

247
267
275
322
369
403
514
556
710
873
1046
1322
1719
1983
2498
2928
3326
3998

329
351
420
566
670
725
956
1193
1332
1616
2256
2797

299
319
381
513
608
659
869
1084
1210
1467
2049
2541

293
316
379
513
604
658
914
1080
1213
1450
2056
2521

265
286
344
465
547
598
829
981
1101
1317
1867
2290

Sr No

Item Description

Unit

Rate ( in Rs.) 2012-2013

Collar Joints

13

700 mm

RMT

14

800 mm

RMT

15

900 mm

RMT

16

1000 mm

RMT

Class P-III

80 mm

RMT

100 mm

RMT

150 mm

RMT

200 mm

RMT

225 mm

RMT

250 mm

RMT

300 mm

RMT

350 mm

RMT

400 mm

RMT

10

450 mm

RMT

11

500 mm

RMT

12

600 mm

RMT

13

700 mm

RMT

14

800 mm

RMT

Rubber Ring
Joints

3811
4583
5163
6249

3461
4163
4689
5675

3466
4177
5202
5626

3148
3794
4724
5109

355
383
437
594
709
829
1151
1502
2067
2372
2895
3719
5305
6738

322
348
397
540
643
753
1046
1364
1878
2155
2630
3378
4819
6119

351
379
438
595
709
830
1151
1502
2067
2373
2896
3720
5305
6738

318
343
397
540
643
752
1045
1364
1878
2156
2629
3378
4818
6119

Class NP-II ( For 2.00 m Length )

80 mm

RMT

100 mm

RMT

150 mm

RMT

200 mm

RMT

225 mm

RMT

250 mm

RMT

300 mm

RMT

290
298
348
407
454
488
652

293
304
354
415
463
498
665

799
928
1088
1272
1679
2422
2767
3545
4243
5327
5703
6778
7782
10901

815
947
1110
1297
1713
2470
2822
3616
4328
5434
5817
6914
7938
11119

328
372
410

335
379
418

( For 2.50 m Length )


8

350 mm

RMT

400 mm

RMT

10

450 mm

RMT

11

500 mm

RMT

12

600 mm

RMT

13

700 mm

RMT

14

800 mm

RMT

15

900 mm

RMT

16

1000 mm

RMT

17

1100 mm

RMT

18

1200 mm

RMT

19

1400 mm

RMT

20

1600 mm

RMT

21

1800 mm

RMT

Class NP-III ( For 2.00 m Length )

80 mm

RMT

100 mm

RMT

150 mm

RMT

Sr No

Item Description

Unit

200 mm

RMT

225 mm

RMT

250 mm

RMT

300 mm

RMT

350 mm

RMT

400 mm

RMT

10

450 mm

RMT

11

500 mm

RMT

12

600 mm

RMT

13

700 mm

RMT

14

800 mm

RMT

15

900 mm

RMT

16

1000 mm

RMT

17

1100 mm

RMT

18

1200 mm

RMT

19

1400 mm

RMT

20

1600 mm

RMT

21

1800 mm

RMT

Class NP-IV

80 mm

RMT

100 mm

RMT

150 mm

RMT

200 mm

RMT

225 mm

RMT

250 mm

RMT

300 mm

RMT

350 mm

RMT

400 mm

RMT

10

450 mm

RMT

11

500 mm

RMT

12

600 mm

RMT

13

700 mm

RMT

14

800 mm

RMT

15

900 mm

RMT

16

1000 mm

RMT

17

1100 mm

RMT

18

1200 mm

RMT

19

1400 mm

RMT

20

1600 mm

RMT

21

1800 mm

RMT

Rate ( in Rs.) 2012-2013

Collar Joints

Rubber Ring
Joints

612
713
763
868
1537
1722
2047
2274
2996
4072
4851
5603
6855
7930
9304
11180
16292
21550

624
727
778
885
1568
1756
2088
2319
3056
4153
4948
5715
6992
8089
9490
11404
16618
21981

353
414
469
655
774
872
1111
1687
1807
2131
2604
3185
4767
5444
6376
9026
9792
9836
15359
19148
26249

360
422
478
668
789
889
1133
1721
1843
2174
2656
3249
4862
5553
6504
9207
9988
10033
15666
19531
26774

Sr No

Item Description

Unit

Rate ( in Rs.) 2012-2013

Collar Joints

Rubber Ring
Joints

Lowering, laying and jointing in proper grade and alignment R.C.C.


pipes with collar joints in C.M.1:1 proportion or socketed R.C.C. pipes
with rubber joints (excluding cost of rubber ring or R.C.C. collar,)
including cost of conveyance from stores to site of work, cost of
jointing material, labour, giving hydraulic testing etc. complete as
directed by Engineer-in-charge (For all class of pipes.) Collar
Joints.as per IS 783/1985

80 mm

RMT

100 mm

RMT

150 mm

RMT

200 mm

RMT

225 mm

RMT

250 mm

RMT

300 mm

RMT

350 mm

RMT

400 mm

RMT

10

450 mm

RMT

11

500 mm

RMT

12

600 mm

RMT

13

700 mm

RMT

14

800 mm

RMT

15

900 mm

RMT

16

1000 mm

RMT

17

1100 mm

RMT

18

1200 mm

RMT

19

1400 mm

RMT

20

1600 mm

RMT

21

1800 mm

RMT

Collar
Joint

Rubber
Ring
Joint

44
53
80
106
124
140
168
173
220
266
290
367
416
482
530
580
806
856
954
1052
1150

31
37
56
75
88
98
118
121
155
185
203
254
289
334
369
404
547
582
652
722
792

Note : Only 85 % rate shall be payable till satisfactory hydraulic testing is given

Section -I ( VII ) PSC - P.S.C.Pipes


Sr No

Item Description

Unit

Rate ( in Rs.)
2012-2013
Without
ED

With ED

Providing ISI standard Pre - stressed Cement concrete pipes (Non steel
cylinder ) pipes of following class and diameter including cost of all meterial
and labour required, cost of all taxes(Central and local) , inspection charges,
transportaion to stores/ site, unloading and stacking etc. complete as per IS
784/2001 .
i) Factory test Pressure
a) Site test pressure +0.1 N/mm2 , For working Pressure upto 1
b) Site test pressure +0.2 N/mm2 , For working Pressure above 1

N/mm2
N/mm2

ii) Site test Pressure - 1.5 times working pressure pertaining to the section
for 1.1 times static pressure , whichever is more ( Such a pressure is to be
controlled within 25 % of pump head in case of pumping main)
iii) Working Pressure - The maximum sustained internal pressure excluding
surge to which each portion of pipeline may be subjected when installed.
All test pressure shall be replaced by Factory test pressure

Note : One rubber ring should be supplied with each pipe, cost of which is included in rates below.
Test Pressure 2 kg/Sq.cm

350 mm

RMT

400 mm

RMT

450 mm

RMT

500 mm

RMT

600 mm

RMT

700 mm

RMT

800 mm

RMT

900 mm

RMT

1000 mm

RMT

10

1100 mm

RMT

11

1200 mm

RMT

12

1300 mm

RMT

13

1400 mm

RMT

14

1500 mm

RMT

15

1600 mm

RMT

16

1700 mm

RMT

1800 mm

RMT

17

3400
3657
3837
4225
5078
5654
6983
8684
10121
11560
13358
15447
16996
19452
21575
23699
25823

3085
3318
3481
3833
4608
5130
6335
7878
9184
10488
12119
14014
15419
17648
19574
21501
23427

3400
3658
3837
4225
5080

3085
3319
3481
3833
4609

Test Pressure 4 kg/Sq.cm

350 mm

RMT

400 mm

RMT

450 mm

RMT

500 mm

RMT

600 mm

RMT

Sr No

Item Description

Unit

Rate ( in Rs.)
2012-2013
Without
ED

700 mm

RMT

800 mm

RMT

900 mm

RMT

1000 mm

RMT

10

1100 mm

RMT

11

1200 mm

RMT

12

1300 mm

RMT

13

1400 mm

RMT

14

1500 mm

RMT

15

1600 mm

RMT

16

1700 mm

RMT

17

1800 mm

RMT

5656
6984
8685
10124
11562
13358
15451
16998
19455
21578
23703
25825

5131
6336
7879
9186
10490
12120
14017
15420
17651
19577
21504
23430

3404
3678
3847
4255
5148
5851
7242
9027
10529
11988
13888
16044
17652
20220
22456
24693
26929

3089
3338
3490
3861
4670
5310
6570
8189
9552
10877
12599
14555
16014
18344
20373
22402
24432

3411
3705
3871
4315
5321
6146
7548
9409
11004
12590
14576

3094
3362
3513
3915
4827
5577
6848
8537
9983
11423
13226

Test Pressure 6 kg/Sq.cm

350 mm

RMT

400 mm

RMT

450 mm

RMT

500 mm

RMT

600 mm

RMT

700 mm

RMT

800 mm

RMT

900 mm

RMT

1000 mm

RMT

10

1100 mm

RMT

11

1200 mm

RMT

12

1300 mm

RMT

13

1400 mm

RMT

14

1500 mm

RMT

15

1600 mm

RMT

16

1700 mm

RMT

17

1800 mm

RMT

With ED

Test Pressure 8 kg/Sq.cm

350 mm

RMT

400 mm

RMT

450 mm

RMT

500 mm

RMT

600 mm

RMT

700 mm

RMT

800 mm

RMT

900 mm

RMT

1000 mm

RMT

10

1100 mm

RMT

11

1200 mm

RMT

Sr No

Item Description

Unit

Rate ( in Rs.)
2012-2013
Without
ED

12

1300 mm

RMT

13

1400 mm

RMT

14

1500 mm

RMT

15

1600 mm

RMT

16

1700 mm

RMT

17

1800 mm

RMT

16861
18637
21355
24097
26838
29579

15299
16909
19376
21861
24348
26836

3428
3757
4007
4489
5550
6396
7933
9886
11577
13285
15392
17821
20144
23092
25733
28372
31012

3110
3407
3635
4071
5035
5802
7197
8969
10505
12053
13964
16168
18275
20951
23347
25742
28138

3512
3855
4134
4642
5771
6683
8309
10333
12105
13879
16357
18944
20960
24004
26746
29490
32232

3185
3498
3750
4211
5235
6064
7539
9375
10984
12592
14842
17089
19017
21777
24266
26754
29243

Test Pressure 10 kg/Sq.cm

350 mm

RMT

400 mm

RMT

450 mm

RMT

500 mm

RMT

600 mm

RMT

700 mm

RMT

800 mm

RMT

900 mm

RMT

1000 mm

RMT

10

1100 mm

RMT

11

1200 mm

RMT

12

1300 mm

RMT

13

1400 mm

RMT

14

1500 mm

RMT

15

1600 mm

RMT

16

1700 mm

RMT

17

1800 mm

RMT

With ED

Test Pressure 12 kg/Sq.cm

350 mm

RMT

400 mm

RMT

450 mm

RMT

500 mm

RMT

600 mm

RMT

700 mm

RMT

800 mm

RMT

900 mm

RMT

1000 mm

RMT

10

1100 mm

RMT

11

1200 mm

RMT

12

1300 mm

RMT

13

1400 mm

RMT

14

1500 mm

RMT

15

1600 mm

RMT

16

1700 mm

RMT

17

1800 mm

RMT

Sr No

Item Description

Unit

Rate ( in Rs.)
2012-2013
Without
ED

Test Pressure 14 kg/Sq.cm

350 mm

RMT

400 mm

RMT

450 mm

RMT

500 mm

RMT

600 mm

RMT

700 mm

RMT

800 mm

RMT

900 mm

RMT

1000 mm

RMT

10

1100 mm

RMT

11

1200 mm

RMT

12

1300 mm

RMT

13

1400 mm

RMT

14

1500 mm

RMT

15

1600 mm

RMT

16

1700 mm

RMT

17

1800 mm

RMT

3598
3957
4262
4792
5993
6972
8688
10827
12915
14840
17205
19860
22633
25936
29004
32072
35141

3263
3591
3866
4348
5437
6326
7882
9823
11717
13464
15610
18018
20534
23531
26315
29099
31883

3675
4064
4391
4950
6213
7266
9063
12030
13539
16249
18754
21585
23826
28302
31744
35186
38627

3335
3687
3985
4492
5637
6592
8222
10915
12283
14740
17015
19584
21617
25677
28800
31923
35044

3761
4176
4518
5105

3412
3788
4099
4631

Test Pressure 16 kg/Sq.cm

350 mm

RMT

400 mm

RMT

450 mm

RMT

500 mm

RMT

600 mm

RMT

700 mm

RMT

800 mm

RMT

900 mm

RMT

1000 mm

RMT

10

1100 mm

RMT

11

1200 mm

RMT

12

1300 mm

RMT

13

1400 mm

RMT

14

1500 mm

RMT

15

1600 mm

RMT

16

1700 mm

RMT

17

1800 mm

RMT

With ED

Test Pressure 18 kg/Sq.cm

350 mm

RMT

400 mm

RMT

450 mm

RMT

500 mm

RMT

Sr No

Item Description

Unit

Rate ( in Rs.)
2012-2013
Without
ED

600 mm

RMT

700 mm

RMT

800 mm

RMT

900 mm

RMT

1000 mm

RMT

10

1100 mm

RMT

11

1200 mm

RMT

12

1300 mm

RMT

13

1400 mm

RMT

14

1500 mm

RMT

15

1600 mm

RMT

16

1700 mm

RMT

17

1800 mm

RMT

With ED

6434
7946
9916
12542
14738
17008
19658
22642
29877
33689
37971
42252
46533

5837
7210
8996
11378
13371
15430
17835
20542
27107
30564
34450
38334
42218

3849
4277
4649
5265
6661
8803
11711
13843
16654
19796
24895
27394
32000
36169
40452
44734
49015

3491
3881
4219
4776
6044
7986
10624
12559
15109
17961
22588
24853
29033
32915
36812
40708
44605

Test Pressure 20 kg/Sq.cm

J
1

350 mm

RMT

400 mm

RMT

450 mm

RMT

500 mm

RMT

600 mm

RMT

700 mm

RMT

800 mm

RMT

900 mm

RMT

1000 mm

RMT

10

1100 mm

RMT

11

1200 mm

RMT

12

1300 mm

RMT

13

1400 mm

RMT

14

1500 mm

RMT

15

1600 mm

RMT

16

1700 mm

RMT

17

1800 mm

RMT

Lowering laying and jointing in proper grade and alignment Prestressed


cement concrete pipe with rubber ring joint including cost of conveyance from
store to site of work all labour involved giving hydraulic test etc complete but
excluding cost of rubber ring ( For all class of pipes )

350 mm

RMT

400 mm

RMT

450 mm

RMT

500 mm

RMT

105
148
179
203

Sr No

Item Description

Unit

Rate ( in Rs.)
2012-2013
Without
ED

600 mm

RMT

700 mm

RMT

800 mm

RMT

900 mm

RMT

1000 mm

RMT

10

1100 mm

RMT

11

1200 mm

RMT

12

1300 mm

RMT

13

1400 mm

RMT

14

1500 mm

RMT

With ED

270
297
334
345
445
585
626
743
784
989

Sr No

Item Description

Unit

Rate ( in Rs.)
2012-2013
Without
ED

15

1600 mm

RMT

16

1700 mm

RMT

17

1800 mm

RMT

With ED

1112
1239
1310

Note : 1)Only 85 % Payment shall be payable till satisfactory hydraulic testing is given
NOTE : 2)Whenever manufacturer is separate& contractor for lowering laying jointing & testing is seperate the principal
contractor shall enter into an aggrement with P S C pipe manufacturer for satisfactory manufacturing transporting lowering laying
jointing & testing of pipe.This foot Note shall appear in tender conditions

Section -I ( VIII ) B.W.S.C. (Bar Wrapped steel Cylinder) Pipes


Sr No

Item Description

Providing and supplying European Standard EN 639/1994 and EN


641/1994 or AWWA C-303 standard reinforced concrete pressure
pipes cylinder type or IS 15155: 2002(Bar wrapped steel cylinder
pipes suitable for overlaping steel welded joint or butt welded steel
joints) of following class and diameter including cost of all material and
labour required, cost of all taxes (Central and State Govt.), inspection
charges, transportation to stores/ site, transit insurance, loading and
unloding and stacking etc. complete.

Unit

Rate ( in Rs.)
2012-2013
Without
With ED
ED

i) Factory test Pressure


a) Site test pressure +0.1 N/mm2 , For working Pressure upto 1
N/mm2
b) Site test pressure +0.2 N/mm2 , For working Pressure above 1
N/mm2
ii) Site test Pressure - 1.5 times working pressure pertaining to the
section for 1.1 times static pressure , whichever is more ( Such a
pressure is to be controlled within 25 % of pump head in case of
pumping main)
iii) Working Pressure - The maximum sustained internal pressure
excluding surge to which each portion of pipeline may be subjected
when installed.
All test pressure shall be replaced by Factory test pressure
Note : 1) Class mentioned below represents the working pressure of pipe.
Note : 2) For external coating at site to the joints , necessary polyethene wrapping for pouring cement slurry
shall also be given free with each pipe.

Working Pressure 4 kg/Sqcm.

350 mm

RMT

400 mm

RMT

450 mm

RMT

500 mm

RMT

600 mm

RMT

700 mm

RMT

800 mm

RMT

900 mm

RMT

1000 mm

RMT

10

1100 mm

RMT

11

1200 mm

RMT

12

1300 mm

RMT

13

1400 mm

RMT

14

1500 mm

RMT

15

1600 mm

RMT

16

1700 mm

RMT

1800 mm

RMT

17

3706
4064
4499
5006
6510
7522
8168
11414
13155
18907
21085
24621
26410
28184
30364
32213
34393

3366
3691
4086
4546
5912
6831
7418
10367
11947
17171
19149
22362
23986
25598
27577
29256
31237

3710
4068

3369
3694

Working Pressure 6 kg/Sqcm.

350 mm

RMT

400 mm

RMT

Sr No

Item Description

Unit

450 mm

RMT

500 mm

RMT

600 mm

RMT

700 mm

RMT

800 mm

RMT

900 mm

RMT

1000 mm

RMT

10

1100 mm

RMT

11

1200 mm

RMT

12

1300 mm

RMT

13

1400 mm

RMT

14

1500 mm

RMT

15

1600 mm

RMT

16

1700 mm

RMT

17

1800 mm

RMT

4501
5013
6517
7528
8175
11421
13160
18913
21090
24627
26416
28192
30370
32219
34399

4089
4554
5920
6838
7425
10373
11953
17179
19157
22367
23992
25604
27584
29262
31243

3713
4071
4506
5025
6528
7540
8186
11432
13172
18925
21102
24638
26427
28203
30382
32230
34411

3373
3698
4092
4564
5928
6847
7434
10383
11964
17187
19165
22378
24002
25614
27594
29272
31253

3717
4075
4509
5040
6544
7555
8202
11437
13187
18941

3375
3702
4095
4577
5943
6862
7449
10398
11978
17202

Working Pressure 8 kg/Sqcm.

350 mm

RMT

400 mm

RMT

450 mm

RMT

500 mm

RMT

600 mm

RMT

700 mm

RMT

800 mm

RMT

900 mm

RMT

1000 mm

RMT

10

1100 mm

RMT

11

1200 mm

RMT

12

1300 mm

RMT

13

1400 mm

RMT

14

1500 mm

RMT

15

1600 mm

RMT

16

1700 mm

RMT

17

1800 mm

RMT

Rate ( in Rs.)
2012-2013
Without
With ED
ED

Working Pressure 10 kg/Sqcm.

350 mm

RMT

400 mm

RMT

450 mm

RMT

500 mm

RMT

600 mm

RMT

700 mm

RMT

800 mm

RMT

900 mm

RMT

1000 mm

RMT

10

1100 mm

RMT

Sr No

Item Description

Unit

11

1200 mm

RMT

12

1300 mm

RMT

13

1400 mm

RMT

14

1500 mm

RMT

15

1600 mm

RMT

16

1700 mm

RMT

1800 mm

RMT

17

350 mm

RMT

400 mm

RMT

450 mm

RMT

500 mm

RMT

600 mm

RMT

700 mm

RMT

800 mm

RMT

900 mm

RMT

1000 mm

RMT

10

1100 mm

RMT

11

1200 mm

RMT

12

1300 mm

RMT

13

1400 mm

RMT

14

1500 mm

RMT

15

1600 mm

RMT

16

1700 mm

RMT

1800 mm

RMT

19180
22392
24016
25629
27608
29286
31268

3720
4079
4513
5059
6564
7575
9368
11448
14231
18960
21138
24675
26464
28538
31570
34171
38004

3379
3704
4099
4597
5961
6880
8507
10398
12925
17221
19200
22411
24036
25921
28673
31036
34516

3724
4083
4526
5152
6683
8695
10196
12574
15138
19037
21130
25286
28572
31792
35451
38923
42585

3383
3707
4110
4679
6069
7898
9259
11420
13750
17291
19191
22965
25951
28874
32197
35351
38678

Working Pressure 14 kg/Sqcm.

350 mm

RMT

400 mm

RMT

450 mm

RMT

500 mm

RMT

600 mm

RMT

700 mm

RMT

800 mm

RMT

900 mm

RMT

1000 mm

RMT

10

1100 mm

RMT

11

1200 mm

RMT

12

1300 mm

RMT

13

1400 mm

RMT

14

1500 mm

RMT

15

1600 mm

RMT

16

1700 mm

RMT

17

1800 mm

RMT

21117
24653
26443
28218
30397
32245
34426

Working Pressure 12 kg/Sqcm.

17

Rate ( in Rs.)
2012-2013
Without
With ED
ED

Working Pressure 16 kg/Sqcm.

Sr No

Item Description

Unit

350 mm

RMT

400 mm

RMT

450 mm

RMT

500 mm

RMT

600 mm

RMT

700 mm

RMT

800 mm

RMT

900 mm

RMT

1000 mm

RMT

10

1100 mm

RMT

11

1200 mm

RMT

12

1300 mm

RMT

13

1400 mm

RMT

14

1500 mm

RMT

15

1600 mm

RMT

16

1700 mm

RMT

17

1800 mm

RMT

3728
4087
4684
5525
7173
9254
11090
13717
16673
20080
23418
27896
31490
35119
39052
43349
48369

3386
3712
4255
5018
6515
8407
10073
12458
15143
18238
21269
25337
28601
31896
35470
39371
43932

3732
4148
4833
5691
7444
9785
11550
14275
17415
20957
24417
28992
33132
36595
41512
46039
50958

3391
3767
4389
5168
6761
8888
10491
12966
15817
19033
22177
26333
30092
33237
37703
41816
46283

3719
4380
5004
6065
7935
10317
12595
15551

3379
3979
4544
5509
7207
9371
11439
14125

Working Pressure 18 kg/Sqcm.

350 mm

RMT

400 mm

RMT

450 mm

RMT

500 mm

RMT

600 mm

RMT

700 mm

RMT

800 mm

RMT

900 mm

RMT

1000 mm

RMT

10

1100 mm

RMT

11

1200 mm

RMT

12

1300 mm

RMT

13

1400 mm

RMT

14

1500 mm

RMT

15

1600 mm

RMT

16

1700 mm

RMT

17

1800 mm

RMT

Rate ( in Rs.)
2012-2013
Without
With ED
ED

Working Pressure 20 kg/Sqcm.

350 mm

RMT

400 mm

RMT

450 mm

RMT

500 mm

RMT

600 mm

RMT

700 mm

RMT

800 mm

RMT

900 mm

RMT

Sr No

Item Description

Unit

1000 mm

RMT

10

1100 mm

RMT

11

1200 mm

RMT

12

1300 mm

RMT

13

1400 mm

RMT

14

1500 mm

RMT

15

1600 mm

RMT

16

1700 mm

RMT

17

1800 mm

RMT

Rate ( in Rs.)
2012-2013
Without
With ED
ED

19029
22835
26549
31538
36348
40934
45721
51075
56537

17282
20741
24114
28644
33012
37179
41525
46389
51351

Note ; 1) For lowering , laying and pouring of cement mortar in the field on joints ( after laying and
welding ), rates as per P.S.C. pipes lowering, laying and jointing shall be adopted.
Note ; 2) For field welding rates applicable for similar welding in M.S. pipes given in that section
shall be adopted.
NOTE : 3) Whenever manufacturer is separate& contractor for lowering laying jointing & testing
is seperate the principal contractor shall enter into an aggrement with B.W. S C pipe manufacturer
for satisfactory manufacturing transporting lowering laying jointing & testing of pipe.This foot Note
shall appear in tender conditions
NOTE : 4) No negative tolerance shall be accepted for the M.S.shell thickness of B.W.S.C. pipes
over the thickness mentioned in EN 641 or AWW AC 303

Section - I- ( IX ) - G.R.P./F.R.P. Pipes


Sr No

Item Description

Providing & supplying Glass fibre reinforced polyester pipes


confirming to BIS 12709 / BIS 14402 with double bell REKA GRP couplings EPDM rubber gaskets for sealing of follosing
pressure diameter and stiffness class including cost of all
material and labour required cost of all taxes (Central and
local) insurance, transportation to site of work / store unloading
and stacking etc. complete.

A
a

Class (SN) 2500


3 Kg/Sq. cm
300mm
350mm
400mm
450mm
500mm
600mm
700mm
800mm
900mm
1000mm
1100mm
1200mm
1300mm
1400mm
1500mm
1600mm
1700mm
1800mm
1900mm
2000mm
2100mm
2200mm
2300mm
2400mm
6 Kg/Sq. cm
300mm
350mm
400mm
450mm
500mm
600mm
700mm
800mm

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

b
1
2
3
4
5
6
7
8

Unit

Rate ( in Rs.)
2012-2013
With ED

Without ED.

RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT

1371
1586
1745
1965
2222
2855
3548
4357
5324
6315
7677
8938
10121
11685
13280
15466
18269
19935
22284
24092
26923
28899
31232
33384

1229
1422
1565
1761
1992
2559
3181
3906
4773
5662
6883
8013
9074
10477
11907
13867
16573
18085
20216
21856
24424
26217
28333
30286

RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT

1422
1626
1827
2029
2307
2988
3715
4552

1275
1458
1638
1819
2068
2679
3331
4081

Sr No

9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

c
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Item Description

900mm
1000mm
1100mm
1200mm
1300mm
1400mm
1500mm
1600mm
1700mm
1800mm
1900mm
2000mm
2100mm
2200mm
2300mm
2400mm
9 Kg/Sq. cm
300mm
350mm
400mm
450mm
500mm
600mm
700mm
800mm
900mm
1000mm
1100mm
1200mm
1300mm
1400mm
1500mm
1600mm
1700mm
1800mm
1900mm
2000mm
2100mm
2200mm
2300mm
2400mm

Unit

Rate ( in Rs.)
2012-2013
With ED

Without ED.

RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT

5545
6595
7992
9249
10583
12109
13814
16111
19038
20715
23181
25033
27987
30159
32504
34710

4972
5913
7166
8293
9489
10857
12385
14445
17271
18793
21029
22710
25389
27360
29488
31489

RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT

1468
1706
1902
2157
2445
3171
3949
4919
6009
7114
8598
9983
11527
13245
15044
17564
20797
22744
25266
27416
30510
32799
35415
38193

1316
1530
1705
1933
2192
2843
3541
4410
5387
6378
7708
8950
10335
11875
13488
15747
18867
20633
22921
24872
27678
29755
32129
34649

Sr No

d
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

e
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

Item Description

12 Kg/Sq. cm
300mm
350mm
400mm
450mm
500mm
600mm
700mm
800mm
900mm
1000mm
1100mm
1200mm
1300mm
1400mm
1500mm
1600mm
1700mm
1800mm
1900mm
2000mm
2100mm
2200mm
15 Kg/Sq. cm
300mm
350mm
400mm
450mm
500mm
600mm
700mm
800mm
900mm
1000mm
1100mm
1200mm
1300mm
1400mm
1500mm
1600mm
1700mm
1800mm

Unit

Rate ( in Rs.)
2012-2013
With ED

Without ED.

RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT

1556
1796
2000
2613
2264
3407
4225
5234
6418
7650
9377
10936
12378
14246
16289
18892
22414
24573
27200
29580
32976
35587

1395
1610
1793
2342
2029
3054
3788
4693
5754
6859
8406
9805
11097
12772
14604
16938
20334
22293
24676
26835
29916
32284

RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT

1620
1871
2080
2398
2756
3642
4543
5669
6987
8292
10173
11804
13549
15595
17692
20527
24695
26988

1452
1677
1865
2150
2471
3265
4073
5082
6264
7434
9121
10583
12147
13982
15862
18404
22403
24483

Sr No

19
20

B
a
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

b
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Item Description

1900mm
2000mm
Class (SN) 5000
3 Kg/Sq. cm
300mm
350mm
400mm
450mm
500mm
600mm
700mm
800mm
900mm
1000mm
1100mm
1200mm
1300mm
1400mm
1500mm
1600mm
1700mm
1800mm
1900mm
2000mm
2100mm
2200mm
6 Kg/Sq. cm
300mm
350mm
400mm
450mm
500mm
600mm
700mm
800mm
900mm
1000mm
1100mm
1200mm
1300mm
1400mm
1500mm
1600mm

Unit

Rate ( in Rs.)
2012-2013
With ED

Without ED.

RMT
RMT

30134
32796

27338
29752

RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT

1470
1724
1965
2234
2472
3222
4033
4999
6155
7321
8874
10401
11843
13612
15533
18058
21385
23454
26105
28394
31611
34120

1317
1546
1761
2004
2216
2889
3616
4482
5519
6564
7956
9325
10618
12204
13926
16190
19400
21277
23682
25758
28677
30954

RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT

1492
1753
1938
2209
2545
3292
4136
5119
6305
7485
9154
10641
12160
13952
15896
18502

1338
1572
1737
1980
2282
2952
3708
4589
5653
6711
8208
9540
10902
12509
14252
16589

Sr No

17
18
19
20
21
22

c
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

d
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

Item Description

1700mm
1800mm
1900mm
2000mm
2100mm
2200mm
9 Kg/Sq. cm
300mm
350mm
400mm
450mm
500mm
600mm
700mm
800mm
900mm
1000mm
1100mm
1200mm
1300mm
1400mm
1500mm
1600mm
1700mm
1800mm
12 Kg/Sq. cm
300mm
350mm
400mm
450mm
500mm
600mm
700mm
800mm
900mm
1000mm
1100mm
1200mm
1300mm
1400mm
1500mm
1600mm
1700mm

Unit

Rate ( in Rs.)
2012-2013
With ED

Without ED.

RMT
RMT
RMT
RMT
RMT
RMT

21907
24020
26757
29152
32429
35057

19874
21791
24274
26446
29420
31804

RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT

1547
1813
2040
2323
2657
3650
4334
5582
6590
7861
12694
14442
16271
18213
20866
23703
28204
30732

1387
1625
1829
2082
2382
3273
3886
5005
5909
7049
11381
12948
14588
16330
18707
21252
25586
27880

RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT

1591
1887
2086
2415
2758
3642
4591
5666
7076
8322
10229
11886
13623
15698
17831
20607
24516

1426
1692
1870
2165
2473
3265
4116
5080
6344
7461
9170
10657
12214
14074
15986
18476
22241

Sr No

Item Description

Unit

Rate ( in Rs.)
2012-2013
With ED

18
19

e
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

Without ED.

1800mm
26951
24450
RMT
1900mm
29866
27095
RMT
15 Kg/Sq. cm
300mm
RMT
1647
1477
350mm
1962
1758
RMT
400mm
2193
1966
RMT
450mm
2533
2271
RMT
500mm
2890
2591
RMT
600mm
3836
3439
RMT
700mm
4827
4328
RMT
800mm
6040
5415
RMT
900mm
7450
6679
RMT
1000mm
8882
7963
RMT
1100mm
10802
9685
RMT
1200mm
12657
11348
RMT
1300mm
14463
12967
RMT
1400mm
16688
14962
RMT
1500mm
18981
17018
RMT
1600mm
21975
19703
RMT
1700mm
26079
23659
RMT
1800mm
28722
26057
RMT
Note :1) For lowering , laying & jointing rates of G.R.P. pipes 50% rates for lowering , laying &
jointing of P.S.C. Pipes of corrosponding diameter shall be adopted.
Note : 2) Whenever manufacturer is separate& contractor for lowering laying jointing & testing is
seperate the principal contractor shall enter into an aggrement with G.R.P. pipe manufacturer for
satisfactory manufacturing transporting lowering laying jointing & testing of pipe.
This foot Note shall appear in tender conditions
Note :3) Only 85 % Payment shall be payable till satisfactory hydraulic testing is given

Section - I - ( X ) - H.D.P.E.Pipes
Sr No

Item Description

Providing and supplying in standard lengths Polyethelene


Pipes , confirming to I.S. 4984 / 14151 / 12786 / 13488 with
necessary jointing material like mechanical connectors I.e.
thread / insert joint / quick release coupler joint / compression
fitting joint or flanged joint , including all local & central taxes ,
transportation & freight charges , inspection charges , loading /
unloading charges , conveyance to the departmental stores /
site & stacking the same in closed shade duely protecting from
sunrays & rains , etc. complete.

A
a

P.E. 100
6 Kg/Sq. Cm
63 mm
75 mm
90 mm
110 mm
125mm
140 mm
160 mm
180 mm
200 mm
225mm
250 mm
280 mm
315 mm
355mm
400mm
450mm
500mm
560mm
630mm
710mm
800mm
900mm
1000mm
8 Kg/Sq. Cm
63 mm
75 mm
90 mm
110 mm
125mm
140 mm
160 mm
180 mm
200 mm
225mm

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23

b
1
2
3
4
5
6
7
8
9
10

Unit

Rate ( in Rs.)
2012-2013
With E.D.

Without ED

RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT

91
132
184
267
364
457
592
746
876
1129
1385
1737
2201
2790
3654
4814
5953
7451
9385
11891
14336
18161
22394

84
119
167
242
330
415
538
678
794
1024
1257
1576
1997
2531
3315
4368
5400
6760
8509
10986
13244
16778
20690

RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT

116
172
231
340
461
576
750
945
1113
1430

105
156
209
308
418
524
680
857
1010
1297

Sr No

11
12
13
14
15
16
17
18
19
20
21
22
23

c
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23

d
1
2
3
4
5
6
7
8

Item Description

250 mm
280 mm
315 mm
355mm
400mm
450mm
500mm
560mm
630mm
710mm
800mm
900mm
1000mm
10 Kg/Sq. Cm
63 mm
75 mm
90 mm
110 mm
125mm
140 mm
160 mm
180 mm
200 mm
225mm
250 mm
280 mm
315 mm
355mm
400mm
450mm
500mm
560mm
630mm
710mm
800mm
900mm
1000mm
12.5 Kg/Sq. Cm
63 mm
75 mm
90 mm
110 mm
125mm
140 mm
160 mm
180 mm

Unit

Rate ( in Rs.)
2012-2013
With E.D.

Without ED

RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT

1762
2210
2794
3537
4645
6212
7663
9618
12109
15344
18509
23430
22868

1598
2004
2536
3209
4215
5635
6951
8725
10978
14176
17100
21646
21127

RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT

145
204
290
428
552
690
895
1136
1331
1704
2129
2628
3376
4236
5643
7509
9280
11161
14659
18618
22441
22710
28067

131
185
264
389
501
625
813
1031
1208
1547
1931
2385
3062
3843
5118
6811
8418
10124
13289
16880
20346
20589
25445

RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT

169
239
345
508
656
822
1070
1354

154
217
314
461
595
746
971
1228

Sr No

9
10
11
12
13
14
15
16
17
18
19
20
21
22
23

e
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23

Item Description

200 mm
225mm
250 mm
280 mm
315 mm
355mm
400mm
450mm
500mm
560mm
630mm
710mm
800mm
900mm
1000mm
16 Kg/Sq. Cm
63 mm
75 mm
90 mm
110 mm
125mm
140 mm
160 mm
180 mm
200 mm
225mm
250 mm
280 mm
315 mm
355mm
400 mm
450mm
500mm
560 mm
630 mm
710 mm
800 mm
900 mm
1000 mm

Unit

Rate ( in Rs.)
2012-2013
With E.D.

Without ED

RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT

1591
2053
2525
3166
4007
5089
6688
8938
11015
13808
17623
18175
21902
27748
33795

1443
1862
2290
2872
3636
4617
6068
8108
9994
12528
15978
16478
19857
25156
30639

RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT

205
288
414
612
790
986
1293
1627
2808
3550
4379
5493
6943
8809
11410
14463
17835
13650
17294
22006
26511
33558
41199

185
262
375
554
717
894
1173
1476
2549
3221
3973
4983
6300
7990
10352
13120
16180
12375
15679
19951
24035
30424
37353

Sr No

Item Description

Providing and Supplying in standard length Polyethylene (PE)


pipes for non pressure underground drainage and sewerage
with smooth internal and corrugated (profiled) external surface
with Anti rodent property confirming to ISO-21138-3:2007with
necessary jointing material like mechanical connector i.e.
thread/insert joint/quick release coupler/compression fitting
joint/ or flanged joint including all local and central taxes,
transportation and freight charges, inspection charges, loading
and unloading charges, conveyance to the departmental
stores /site and stacking the same in closed shade duly
protecting from sunrays and rains etc complete

Unit

Rate ( in Rs.)
2012-2013
With E.D.

HDPE PIPES FOR DRAINAGE


Class SN4
i)
ii)
iii)
iv)
v)

160 mm (OD)
175 mm(OD)
200 mm(OD)
250 mm(OD)
315 mm(OD)

i)
ii)
iii)
iv)
v)

160 mm (OD)
175 mm(OD)
200 mm(OD)
250 mm(OD)
315 mm(OD)
Lowering laying and Jointing HDPE pipes by heating to the
ends of pipes with the help of tefflon coated disc & hot flame
blower to the required temparature and then pressing the ends
together against each other , to form a monolithic & leakproof
joint by thermosetting process. The pressing may be required
to be done with jig fixtures etc. complete. with all material
labour as directed by Engineer-in-charge ,including giving
satisfactory hydraulic test.
For All classes
20mm
25mm
32mm
40mm
50mm
63mm
75mm
90mm
110mm
125mm
140mm
160mm
180mm
200mm

Rmt
Rmt
Rmt
Rmt

280
320
400
592
840

Rmt
Rmt
Rmt
Rmt
Rmt

304
365
440
840
1056

Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt

10
15
20
25
30
37
40
55
58
66
89
95
95
106

Rmt

Class SN8

i)
ii)
iii)
iv)
v)
vi)
vii)
viii)
ix)
x)
xi)
xii)
xiii)
xiv)

Without ED

Sr No

Item Description

Unit

Rate ( in Rs.)
2012-2013
With E.D.

xv)
xvi)
xvii)
xviii)
xix)
xx)
xxi)
xxii)
xxiii)
xxix)

225mm
250mm
280mm
315mm
355mm
400mm
450mm
500mm
560mm
630mm

Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt

136
141
174
191
209
211
238
308
345
388

Rmt
Rmt
Rmt
Rmt
Rmt

32
36
39
49
60

Lowering ,Laying and jointing HDPE Double Wall Corrugated


Pipes for non pressure Underground drainage and Sewerage
applications and specials of following class and diameter
including cost of conveyance from stores to site of works
including cost of all labour material except O ring coupler
giving satisfactory hydraulic testing as per relevant ISO etc
complete

Rate for SN 4 and SN8


i)
ii)
iii)
iv)
v)

160MM (OD)
175MM (OD)
200MM (OD)
250MM (OD)
315MM (OD)

Without ED

Section - I - ( X )A - MDPE.Pipes
Sr No

Item Description

Unit

Rate ( in Rs.)
2012-2013
With E.D.

Without
ED

Providing and Supplying Blue MDPE pipes conforming to ISO


4427:1996 manufactured from virgin resin PE 80 Food grade
compounded Raw Material having Blue Colour only with
quality assurance certificate from quality agencies like WRC /
CIPET (India) / DVGM / KIWA / SPGN etc. for usage in
Drinking Water syatem The cost shall include testing of all
materials, all taxes Central,Sate ,Municipal,Inspection
charges, transportation up to site, transitinsurance, loading,
unloading, stacking etc. complete as specified and directed.

i)
ii)
iii)
iv)
v)
vi)
vii)
viii)
ix)
x)
xi)
xii)
vii)
viii)
ix)
x)
xi)
xii)

PN 16 (SDR 9)
20 mm
25 mm
32 mm
40 mm
50 mm
63 mm
75 mm
90 mm
110 mm
125 mm
140 mm
160 mm
180 mm
200 mm
225 mm
250 mm
280 mm
315 mm

Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt

28
40
66
97
148
218
295
426
633
817
1027
1361
1722
2129
2697
3316
4169
5362

26
36
59
87
132
194
262
379
563
727
914
1211
1533
1895
2400
2952
3711
4772

B)
i)
ii)
iii)
iv)
v)
vi)
vii)
viii)
ix)
x)
xi)
xii)
vii)

PN 12.5 (SDR 11)


25 mm
32 mm
40 mm
50 mm
63 mm
75 mm
90 mm
110 mm
125 mm
140 mm
160 mm
180 mm
200 mm

Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt

37
62
90
130
175
245
359
526
684
854
1118
1439
1778

33
55
84
116
158
219
316
468
609
760
995
1291
1581

Sr No

Item Description

Unit

Rate ( in Rs.)
2012-2013
With E.D.

Without
ED

viii)
ix)
x)
xi)

225 mm
250 mm
280 mm
315 mm

Rmt
Rmt
Rmt
Rmt

2248
2770
3471
4400

2001
2479
3089
3916

C)
i)
ii)
iii)
iv)
v)
vi)
vii)
viii)
ix)
x)
xi)
xii)
xiii)

PN 10 (SDR 13.6)
63 mm
75 mm
90 mm
110 mm
125 mm
140 mm
160 mm
180 mm
200 mm
225 mm
250 mm
280 mm
315 mm

Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt

150
212
305
450
579
727
951
1205
1483
1881
2315
2900
3662

134
189
272
401
516
647
846
1072
1320
1673
2060
2581
3259

D)
i)
ii)
iii)
iv)
v)
vi)
vii)
viii)
ix)
x)
xi)
xii)
xii)
E)
i)
ii)
iii)
iv)
v)
vi)
vii)
viii)
ix)

PN 8 (SDR 17)
63 mm
75 mm
90 mm
110 mm
125 mm
140 mm
160 mm
180 mm
200 mm
225 mm
250 mm
280 mm
315 mm
PN 6 (SDR 21)
63 mm
75 mm
90 mm
110 mm
125 mm
140 mm
160 mm
180 mm
200 mm

Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt

122
171
247
367
470
589
771
977
1203
1528
1875
2399
3040

108
152
220
327
418
524
686
870
1071
1360
1705
2135
2705

Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt
Rmt

94
136
190
284
374
460
602
756
939

84
121
169
258
326
410
536
672
836

Sr No

Item Description

Unit

Rate ( in Rs.)
2012-2013
With E.D.

x)
xi)
xii)
xiii)

225 mm
250 mm
280 mm
315 mm

Providing & Supply of Electro Fusion Fittings in accordance


with BS EN12201: Part-3 suitable for drinking water with in
black/ blue colour manufactured from compounded PE80/
PE100 virgin polymer and compatible with PE80/PE100 pipes,
in pressure rating SDR11 with min PN12.5 rated for water
application and shall be inclusive of all cost such as testing, all
taxes related to central, state & municipal, inspection charges,
transportation up to site, transit insurance, loading, unloading,
stacking etc. complete.

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

Couplers
Couplers
Couplers
Couplers
Couplers
Couplers
Couplers
Couplers
Couplers
Couplers
Couplers
Couplers
Couplers
Couplers
Couplers
Couplers
Couplers
Couplers

19
20
21
22
23
24
25
26
27
28
29
30

Equal
Equal
Equal
Equal
Equal
Equal
Equal
Equal
Equal
Equal
Equal
Equal

20
25
32
40
50
63
75
90
110
125
140
160
180
200
225
250
280
315

Tee
Tee
Tee
Tee
Tee
Tee
Tee
Tee
Tee
Tee
Tee
Tee

20
25
32
40
50
63
75
90
110
125
160
180

Rmt
Rmt
Rmt
Rmt

1189
1452
1836
2309

No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.

100
100
100
173
217
257
435
476
664
675
1446
1569
2254
2530
3189
4973
5600
6116

No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.

210
210
210
463
473
775
1135
1620
2250
3104
5380
6758

Without
ED

1058
1293
1634
2055

Sr No

Item Description

Unit

Rate ( in Rs.)
2012-2013
With E.D.

31
32
33

Equal Tee 200


Equal Tee 225
Equal Tee 250

34
35
36
37
38
39
40
41
42
43
44
45
46
47
48

Elbow
Elbow
Elbow
Elbow
Elbow
Elbow
Elbow
Elbow
Elbow
Elbow
Elbow
Elbow
Elbow
Elbow
Elbow

90 Deg.
90 Deg.
90 Deg.
90 Deg.
90 Deg.
90 Deg.
90 Deg.
90 Deg.
90 Deg.
90 Deg.
90 Deg.
90 Deg.
90 Deg.
90 Deg.
90 Deg.

49
50
51
52
53
54
55
56
57
58
59
60
61

Elbow
Elbow
Elbow
Elbow
Elbow
Elbow
Elbow
Elbow
Elbow
Elbow
Elbow
Elbow
Elbow

45 Deg.
45 Deg.
45 Deg.
45 Deg.
45 Deg.
45 Deg.
45 Deg.
45 Deg.
45 Deg.
45 Deg.
45 Deg.
45 Deg.
45 Deg.

62
63
64
65
66
67
68
69
70
71

Reducer
Reducer
Reducer
Reducer
Reducer
Reducer
Reducer
Reducer
Reducer
Reducer

25X20
32X20
32X25
40X32
50X32
50X40
63X32
63X40
63X50
90X63

No.
No.
No.

10832
12215
17895

20
25
32
40
50
63
75
90
110
125
160
180
200
225
250

No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.

112
112
113
153
181
252
394
465
641
816
1786
2070
2679
5840
10943

32
40
50
63
75
90
110
125
160
180
200
225
250

No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.

120
145
172
240
374
442
641
816
1503
1970
2070
2679
5840

No.
No.
No.
No.
No.
No.
No.
No.
No.
No.

150
158
165
179
179
179
217
217
217
536

Without
ED

Sr No

Item Description

Unit

Rate ( in Rs.)
2012-2013
With E.D.

72
73
74
75
76
77
78
79
80

Reducer 110X75
Reducer 110X90
Reducer 125X90
Reducer 160X110
Reducer 180X125
Reducer 200X160
Reducer 225X160
Reducer 250X160
Reducer 250X200

No.
No.
No.
No.
No.
No.
No.
No.
No.

697
697
774
1369
1705
2020
2955
4082
4465

81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97

End Cap
End Cap
End Cap
End Cap
End Cap
End Cap
End Cap
End Cap
End Cap
End Cap
End Cap
End Cap
End Cap
End Cap
End Cap
End Cap
End Cap

No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.

40
40
55
60
64
84
308
351
493
624
1021
1106
1286
2055
3530
4550
7527

98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113

Ferrule tapping tee 63 x 1/2"


Ferrule tapping tee 63 x 3/4"
Ferrule tapping tee 63 x 1"
Ferrule tapping tee 75 x 1/2"
Ferrule tapping tee 75 x 3/4"
Ferrule tapping tee 75 x 1"
Ferrule tapping tee 90 x 1/2"
Ferrule tapping tee 90 x 3/4"
Ferrule tapping tee 90 x 1"
Ferrule tapping tee 90 x 11/4"
Ferrule tapping tee 90 x 11/2"
Ferrule tapping tee 90 x 2"
Ferrule tapping tee 110 x 1/2"
Ferrule tapping tee 110 x 3/4"
Ferrule tapping tee 110 x 1"
Ferrule tapping tee 110 x 11/4"

No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.

757
757
757
757
757
757
757
757
757
982
982
982
757
757
757
982

20
25
32
40
50
63
75
90
110
125
140
160
180
200
225
250
315

Without
ED

Sr No

Item Description

Unit

Rate ( in Rs.)
2012-2013
With E.D.

114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
3

1
2
3
4
5
6
7
8

Ferrule tapping tee 110 x 11/2"


Ferrule tapping tee 110 x 2"
Ferrule tapping tee 160 x 1/2"
Ferrule tapping tee 160 x 3/4"
Ferrule tapping tee 160 x 1"
Ferrule tapping tee 160 x 11/4"
Ferrule tapping tee 160 x 11/2"
Ferrule tapping tee 160 x 2"
Ferrule tapping tee 200 x 1/2"
Ferrule tapping tee 200 x 3/4"
Ferrule tapping tee 200 x 1"
Ferrule tapping tee 200 x 11/4"
Ferrule tapping tee 200 x 11/2"
Ferrule tapping tee 200 x 2"
Ferrule tapping tee 250 x 1/2"
Ferrule tapping tee 250 x 3/4"
Ferrule tapping tee 250 x 1"
Ferrule tapping tee 250 x 11/4"
Ferrule tapping tee 250 x 11/2"
Ferrule tapping tee 250 x 2"
Ferrule tapping tee 315 x 1/2"
Ferrule tapping tee 315 x 3/4"
Ferrule tapping tee 315 x 1"
Ferrule tapping tee 315 x 11/4"
Ferrule tapping tee 315 x 11/2"
Ferrule tapping tee 315 x 2"

No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.

982
982
757
757
757
1070
1070
1070
1068
1068
1068
1540
1540
1540
1068
1068
1068
1540
1540
1540
1271
1271
1271
1726
1726
1726

No.
No.
No.
No.
No.
No.
No.
No.

68
78
100
184
241
344
73
86

Providing & Supply of Compression fittings, PN16 rated in


conformation to ISO:14236-2000 and shall be tested as per
ISO:3459, ISO:3501 & ISO:3503,suitable for drinking water &
approved by WRAS, UK/ KIWA etc, in food grade
polypropylene and shall be inclusive of all cost such as testing,
all taxes related to central, state & municipal, inspection
charges, transportation up to site, transit insurance, loading,
unloading, stacking etc. complete.
Compression Fittings List Price
Description
Male Adaptor 20x1/2"
Male Adaptor 25x3/4"
Male Adaptor 32x1"
Male Adaptor 40x1 1/4"
Male Adaptor 50x1 1/2"
Male Adaptor 63x2"
Female Adaptor 20x1/2"
Female Adaptor 25x3/4"

Without
ED

Sr No

Item Description

Unit

Rate ( in Rs.)
2012-2013
With E.D.

9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52

Female Adaptor 32x1"


Female Adaptor 40x1 1/4"
Female Adaptor 50x1 1/2"
Female Adaptor 63x2"
Coupling 20x20
Coupling 25x25
Coupling 32x32
Coupling 40x40
Coupling 50x50
Coupling 63x63
Reducing Coupling 25x20
Reducing Coupling 32x20
Reducing Coupling 32x25
Reducing Coupling 40x25
Reducing Coupling 40x32
Reducing Coupling 50x32
Reducing Coupling 50x40
Reducing Coupling 63x50
90 Deg. Elbow 20
90 Deg. Elbow 25
90 Deg. Elbow 32
90 Deg. Elbow 40
90 Deg. Elbow 50
90 Deg. Elbow 63
90 Deg. Elbow threaded male off take 20x1/2"
90 Deg. Elbow threaded male off take 25x3/4"
90 Deg. Elbow threaded male off take 32x1"
90 Deg. Elbow threaded male off take 40x11/4"
90 Deg. Elbow threaded male off take 50x11/2"
90 Deg. Elbow threaded male off take 63x2"
90 Deg. Elbow threaded female off take 20x1/2"
90 Deg. Elbow threaded female off take 25x3/4"
90 Deg. Elbow threaded female off take 32x1"
90 Deg. Elbow threaded female off take 40x11/4"
90 Deg. Elbow threaded female off take 50x11/2"
90 Deg. Elbow threaded female off take 63x2"
Equal Tee 20x20x20
Equal Tee 25x25x25
Equal Tee 32x32x32
Equal Tee 40x40x40
Equal Tee 50x50x50
Equal Tee 63x63x63
End Cap 20
End Cap 25

No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.

108
202
259
365
70
77
98
187
240
347
128
169
169
289
289
374
374
530
130
155
190
312
443
600
78
95
123
197
269
374
89
110
132
257
337
443
155
204
264
436
590
839
40
40

Without
ED

Sr No

Item Description

Unit

Rate ( in Rs.)
2012-2013
With E.D.

53
54
55
56

End Cap 32
End Cap 40
End Cap 50
End Cap 63

No.
No.
No.
No.

55
60
64
84

Without
ED

Section - I - ( XI ) - P.C.C.P. Pipes


Sr No

Item Description

Unit

Rate ( in Rs.)
2012 2013
2012-2013
With E.D.

Without ED

Providing and supplying Prestressed Concrete Cylinder Pipes


suitable for sliding overlap weld joint or confined rubber ring
joint with necessary rubber ring of following class and
diameters including cost of all taxes (Central and local)
inspection charges
charges, transportation to site of work / store
store, transit
insurance, unloading and stacking etc. complete.
As per IS 784:2001
i) Factory test Pressure
a) Site test pressure +0.1 N/mm2 , For working Pressure upto 1
N/mm2
b) Site test pressure +0.2 N/mm2 , For working Pressure above 1
N/mm2
ii) Site test Pressure - 1.5 times working pressure pertaining to the
section or 1.1 times static pressure , whichever is more ( Such a
pressure is to be controlled within 25 % of pump head in case of
pumping main)
iii) Working Pressure - The maximum sustained internal pressure
excluding surge to which each portion of pipeline may be subjected
when installed.
All test pressure shall be replaced by Factory test pressure

a
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

b
1
2
3
4
5
6

TP 4Kg/Sq
4Kg/Sq.Cm.
Cm
350 mm
400 mm
450mm
500 mm
600 mm
700 mm
800 mm
900 mm
1000 mm
1100mm
1200mm
1300 mm
1400mm
1500 mm
1600 mm
1700mm
1800mm

RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT

4464
4909
5390
5965
7213
8334
9382
11499
13280
14870
16349
18890
20511
21993
23476
24958
26440

4054
4457
4896
5417
6551
7569
8522
10445
12062
13505
14849
17156
18628
19975
21321
22668
24014

TP 5.5 Kg/Sq.Cm.
350 mm
400 mm
450mm
500 mm
600 mm
700 mm

RMT
RMT
RMT
RMT
RMT
RMT

4464
4930
5417
6000
7262
8400

4054
4479
4923
5449
6596
7629

Sr No

Item Description

Unit

Rate ( in Rs.)
2012-2013
With E.D.
ED

With t ED
Without

7
8
9
10
11
12
13
14
15
16
17

800 mm
900 mm
1000 mm
1100mm
1200mm
1300 mm
1400mm
1500 mm
1600 mm
1700mm
1800mm

RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT

9493
11606
13412
15040
17157
19169
20866
22350
23832
25315
26797

8621
10542
12181
13661
15584
17409
18952
20298
21646
22992
24339

TP 7 Kg/Sq.Cm.
350 mm
400 mm
450mm
500 mm
600 mm
700 mm
800 mm
900 mm
1000 mm
1100mm
1200mm
1300 mm
1400mm
1500 mm
1600 mm
1700mm
1800mm

RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT

4475
4951
5445
6032
7312
8479
9629
11756
13613
15289
17455
19518
21450
22384
23867
25349
26831

4063
4496
4945
5478
6641
7701
8745
10677
12366
13886
15853
17728
19483
20329
21676
23023
24369

TP 8.5 Kg/Sq.Cm.
350 mm
400 mm
450mm
500 mm
600 mm
700 mm
800 mm
900 mm
1000 mm
1100mm
1200mm
1300 mm

RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT

4492
4976
5473
6067
7376
8578
9765
11923
13819
15537
17903
20032

4080
4520
4970
5510
6700
7790
8869
10828
12550
14112
16261
18194

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

d
1
2
3
4
5
6
7
8
9
10
11
12

Sr No

Item Description

Unit

Rate ( in Rs.)
2012-2013
With E.D.
ED

With t ED
Without

13
14
15
16
17

1400mm
1500 mm
1600 mm
1700mm
1800mm

RMT
RMT
RMT
RMT
RMT

21859
22789
24273
25755
27237

19853
20699
22045
23392
24738

TP 10 Kg/Sq.Cm.
350 mm
400 mm
450mm
500 mm
600 mm
700 mm
800 mm
900 mm
1000 mm
1100mm
1200mm
1300 mm
1400mm
1500 mm
1600 mm
1700mm
1800mm

RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT

4508
4995
5506
6117
7449
8677
9913
12087
14024
15926
18207
20390
22276
23209
24692
26175
27657

4095
4539
5002
5555
6764
7880
9003
10978
12736
14465
16536
18520
20233
21079
22427
23773
25120

TP11.5 Kg/Sq.Cm.
350 mm
400 mm
450mm
500 mm
600 mm
700 mm
800 mm
900 mm
1000 mm
1100mm
1200mm
1300 mm
1400mm
1500 mm
1600 mm
1700mm
1800mm

RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT

4527
5027
5550
6169
7523
8774
10188
12254
14228
16181
18513
20751
22699
23631
25113
26596
28078

4111
4567
5039
5602
6833
7968
9254
11131
12922
14696
16814
18848
20617
21462
22809
24155
25502

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

f
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

Sr No

Item Description

Unit

Rate ( in Rs.)
2012-2013
With E.D.
ED

g
1
2
3
4
5
6
7
8
9
10

TP 13 Kg/Sq.Cm.
350 mm
400 mm
450mm
500 mm
600 mm
700 mm
800 mm
900 mm
1000 mm
1100mm

RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT

4562
5069
5594
6220
7595
8874
10356
12421
14526
16438

With t ED
Without

4143
4604
5081
5649
6898
8058
9407
11281
13193
14930

Sr No

Item Description

Unit

Rate ( in Rs.)
2012-2013
With E.D.
ED

With t ED
Without

11
12
13
14
15
16
17

1200mm
1300 mm
1400mm
1500 mm
1600 mm
1700mm
1800mm

RMT
RMT
RMT
RMT
RMT
RMT
RMT

18823
21120
23116
24047
25530
27012
28494

17095
19181
20995
21841
23188
24534
25871

TP 14.5 Kg/Sq.Cm.
350 mm
400 mm
450mm
500 mm
600 mm
700 mm
800 mm
900 mm
1000 mm
1100mm
1200mm
1300 mm
1400mm
1500 mm
1600 mm
1700mm
1800mm

RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT

4601
5116
5649
6279
7672
9456
10525
12706
14739
16696
19130
21479
24161
25092
26575
28057
29539

4179
4646
5131
5703
6968
8588
9559
11541
13386
15163
17374
19507
21944
22789
24137
25483
26830

TP17 Kg/Sq.Cm.
350 mm
400 mm
450mm
500 mm
600 mm
700 mm
800 mm
900 mm
1000 mm
1100mm
1200mm
1300 mm
1400mm
1500 mm
1600 mm
1700mm

RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT

4636
5162
5707
6347
7771
9076
10728
12889
14955
16964
19440
21844
24628
25558
27041
28524

4212
4689
5183
5765
7057
8244
9745
11705
13581
15408
17656
19840
22367
23214
24560
25907

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

I
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

Sr No

Item Description

Unit

Rate ( in Rs.)
2012-2013
With E.D.
ED

17

1800mm

RMT

30006

With t ED
Without

27253

Sr No

Item Description

Unit

Rate ( in Rs.)
2012-2013
With E.D.
ED

j
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

k
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

l
1
2
3

With t ED
Without

TP 18.5 Kg/Sq.Cm.
350 mm
400 mm
450mm
500 mm
600 mm
700 mm
800 mm
900 mm
1000 mm
1100mm
1200mm
1300 mm
1400mm
1500 mm
1600 mm
1700mm
1800mm

RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT

4674
5209
5765
6417
7870
9189
11082
13113
15211
17231
19752
22892
25266
25671
27153
28635
30119

4245
4731
5236
5828
7148
8347
10064
11910
13814
15649
17940
20793
22948
23314
24662
26009
27355

TP 20 Kg/Sq.Cm.
350 mm
400 mm
450mm
500 mm
600 mm
700 mm
800 mm
900 mm
1000 mm
1100mm
1200mm
1300 mm
1400mm
1500 mm
1600 mm
1700mm
1800mm

RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT

4711
5257
5822
6489
7968
9416
11349
13415
15564
17638
20785
23387
25824
26227
27710
29192
30674

4278
4775
5288
5894
7237
8552
10306
12182
14135
16019
18878
21241
23453
23821
25168
26514
27861

TP 21.5 Kg/Sq.Cm.
350 mm
400 mm
450mm

RMT
RMT
RMT

4750
5302
5880

4316
4817
5340

Sr No

Item Description

Unit

Rate ( in Rs.)
2012-2013
With E.D.
ED

With t ED
Without

4
5
6
7
8
9
10
11
12
13
14
15
16
17

500 mm
600 mm
700 mm
800 mm
900 mm
1000 mm
1100mm
1200mm
1300 mm
1400mm
1500 mm
1600 mm
1700mm
1800mm

RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT

6559
8084
9879
11528
13711
15918
18527
21302
23929
27241
27647
29129
30611
32094

5957
7342
8973
10469
12453
14457
16827
19347
21733
24741
25109
26457
27803
29150

TP 23 Kg/Sq.Cm.
350 mm
400 mm
450mm
500 mm
600 mm
700 mm
800 mm
900 mm
1000 mm
1100mm
1200mm
1300 mm
1400mm
1500 mm
1600 mm
1700mm
1800mm

RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT

4787
5350
5939
6628
8254
10190
11880
14008
16270
19017
21825
24612
27747
28150
29632
31116
32598

4349
4859
5394
6020
7497
9256
10790
12723
14778
17272
19823
22353
25200
25567
26915
28261
29607

TP 24.5 Kg/Sq.Cm.
350 mm
400 mm
450mm
500 mm
600 mm
700 mm
800 mm
900 mm
1000 mm

RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT

4825
5398
5997
6699
8586
10331
12097
14244
17036

4382
4902
5447
6084
7798
9383
10986
12938
15472

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

n
1
2
3
4
5
6
7
8
9

Sr No

Item Description

Unit

Rate ( in Rs.)
2012-2013
With E.D.
ED

10
11
12
13
14
15
16
17

1100mm
1200mm
1300 mm
1400mm
1500 mm
1600 mm
1700mm
1800mm

RMT
RMT
RMT
RMT
RMT
RMT
RMT
RMT

With t ED
Without

19508
22354
26559
28276
28677
30159
31642
33124

17718
20305
24122
25682
26045
27392
28738
30085

Note ; 1) For P.C.C.P pipes lowering , laying and pouring of cement mortar in the field on joints
(after laying and welding ), rates as per P.S.C. pipes lowering, laying and jointing shall be
adopted
adopted.
Note ; 2) For field welding rates applicable for similar welding in M.S. pipes given in that
section shall be adopted.
NOTE : 3) Whenever manufacturer is separate& contractor for lowering laying jointing &
testing is seperate the principal contractor shall enter into an aggrement with P C C P pipe
manufacturer for satisfactory manufacturing transporting lowering laying jointing & testing of
pipe.This foot Note shall appear in tender conditions

Section - I - ( XII ) - Pipe Appurtenances


Sr No

Item Description

Providing and supplying ISI mark CI D/F reflux valves (non-return


valves ) of following dia including all taxes (Central and Local),
railway freight, inspection charges unloding from railway wagon,
loading into truck, transportation upto departmental stroes/ site,
unloading, stacking etc. complete. Reflux valves as per I.S.5312 Part
I (1984)
CI D/F reflux valves (non-return valves ) With Third Party
Inspection
Without by pass arrangement - PN -1

A
a

Unit

50 mm

No

65 mm

No

80 mm

No

100 mm

No

125 mm

No

150 mm

No

200 mm

No

250 mm

No

300 mm

No

10

350 mm

No

11

400 mm

No

12

450 mm

No

13

500 mm

No

14

600 mm

No

15

700 mm

No

3308
3873
4078
5694
8130
9844
17694
30194
41374
68478
94273
111059
181880
266900
468495

With by pass arrangement - PN -1

80 mm

No

100 mm

No

125 mm

No

150 mm

No

200 mm

No

250 mm

No

300 mm

No

350 mm

No

400 mm

No

10

450 mm

No

11

500 mm

No

12

600 mm

No

13

700 mm

No

14

750 mm

No

15

800 mm

No

16

900 mm

No

17

1000 mm

No

Rate ( in Rs.)
2012-2013

4709
6708
9134
10848
20224
33057
44373
72752
97627
114222
185408
270477
709220
776307
843396
920068
1073413

Without by pass arrangement - PN-1.6

50 mm

No

65 mm

No

80 mm

No

100 mm

No

125 mm

No

150 mm

3227
3486
5718
7323
10203
11419

Sr No

Item Description

Unit

200 mm

No

250 mm

No

300 mm

No

10

350 mm

No

11

400 mm

No

12

450 mm

No

13

500 mm

No

14

600 mm

No

15

700 mm

No

16

750 mm

No

17

800 mm

No

18

900 mm

No

19

1000 mm

No

20

1100 mm

No

21

1200 mm

No

d
1

50 mm

No

65 mm

No

80 mm

No

100 mm

No

125 mm

150 mm

No

200 mm

No

250 mm

No

300 mm

No

10

350 mm

No

11

400 mm

No

12

450 mm

No

13

500 mm

No

14

600 mm

No

15

700 mm

No

16

750 mm

No

17

800 mm

No

18

900 mm

No

19

1000 mm

No

20

1100 mm

No

1200 mm

No

A
a

24284
38986
54474
93820
108424
127927
207834
305384
369010
423608
481972
609995
753081
911227
1084436

With by pass arrangement - PN-1.6

21

Rate ( in Rs.)
2012-2013

3312
3727
5484
7092
9911
12030
24298
36715
51028
85713
112272
131355
213216
311049
375853
431463
490910
621308
767046
928125
1104545

Providing and supplying double flange sluice valves confirming for IS


2906/14846 including warn gear arrangement as per test pressure
stainless steel spindle caps including all taxes transportation etc
complete.
Without byepass
Sluice valves - PN -1

50 mm

No

65 mm

No

80 mm

No

100 mm

No

125 mm

No

150 mm

No

4391
4985
5116
6812
8521
10217

Sr No

Item Description

Unit

200 mm

No

250 mm

No

Rate ( in Rs.)
2012-2013

300 mm

No

10

350 mm

No

11

400 mm

No

12

450 mm

No

13

500 mm

No

14

600 mm

No

15

700 mm

No

16

750 mm

No

17

800 mm

No

18

900 mm

No

19

1000 mm

No

20

1100 mm

No

21

1200 mm

No

19333
29913
37695
53477
72101
88187
113477
167606
300430
342603
427239
550860
814189
1078533
1280269

No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No

4391
4985
5116
6812
8521
12374
21854
33263
40982
58087
77248
93275
120104
174198
310617
351996
437316
561585
826615
1093680
1293675

5803
6371
7265
9636
12024
11893
24101
37382
49699

With by pass arrangement - PN-1.

i)
ii)
iii)
iv)
v)
vi)
vii)
viii)
ix)
x)
xi)
xii)
xiii)
xiv)
xv)
xvi)
xvii)
xviii)
xix)
xx)
xxi)
b

50 mm
65 mm
80 mm
100 mm
125 mm
150 mm
200 mm
250 mm
300 mm
350 mm
400 mm
450 mm
500 mm
600 mm
700 mm
750 mm
800 mm
900 mm
1000 mm
1100 mm
1200 mm
, Sluice valves without byepass arrangement - PN -1.6

50 mm

No

65 mm

No

80 mm

No

100 mm

No

125 mm

No

150 mm

No

200 mm

No

250 mm

No

300 mm

No

Sr No

Item Description

Unit

10

350 mm

No

11

400 mm

No

12

450 mm

No

13

500 mm

No

14

600 mm

No

15

700 mm

No

16

750 mm

No

17

800 mm

No

18

900 mm

No

19

1000 mm

No

20

1100 mm

No

21

1200 mm

No

d)

Rate ( in Rs.)
2012-2013

72811
99720
123737
160146
243982
524772
579078
672599
813137
1183325
1285723
1721030

Sluice valve - PN - 1.6


with byepass arrangement

xx)

1100 mm

No

xxi)

1200 mm

No

5803
6371
7265
9636
12024
14014
26755
40969
53299
77866
105441
129463
167602
251533
538550
589319
682470
823468
1195568
1297614
1734270

Providing , and supplying double flanged short body pattern


type manually operated Butterfly Valve having body, disc and
end cover in graded cast iron to IS 210 Gr. CF 200 generally
conforming in BS 5155, Synthetic rubber faced ring secured
on disc by retaining ring with stainless steel screw stub shaft
of stainless steel riding in teflon bearings excluding C. C.
foundation/ structural steel support confirming to IS 130951991,etc complete
- PN -1.0 with byepass arrangement
80 mm
100 mm
125 mm

No
No
No

5808
7424
8467

i)

50 mm

No

ii)

65 mm

No

iii)

80 mm

No

iv)

100 mm

No

v)

125 mm

No
No

vi)

150 mm

vii)

200 mm

No

viii)

250 mm

No

ix)

300 mm

No

x)

350 mm

No

xi)

400 mm

No

xii)

450 mm

No

xiii)

500 mm

No

xiv)

600 mm

No

xv)

700 mm

No

xvi)

750 mm

No

xvii)

800 mm

No

xviii)

900 mm

No

xix)

1000 mm

No

a)
1
2
3

Sr No

Item Description

Unit

Rate ( in Rs.)
2012-2013

4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

150 mm
200 mm
250 mm
300 mm
350 mm
400 mm
450 mm
500 mm
600 mm
700 mm
750 mm
800 mm
900 mm
1000 mm
1100 mm
1200 mm
1400 mm
1500 mm

No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No

10944
14586
18230
28844
58665
63023
72811
79947
98727
159784
198334
218214
301378
358723
581758
550499
839367
1042954

b)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

Butterfly Valve with byepass arrangement


Butterfly valve - PN - 1.6
80 mm
100 mm
125 mm
150 mm
200 mm
250 mm
300 mm
350 mm
400 mm
450 mm
500 mm
600 mm
700 mm
750 mm
800 mm
900 mm
1000 mm
1100 mm
1200 mm
1400 mm
1500 mm

No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No

6444
8537
9317
12585
16776
20965
33171
67464
72476
83733
91939
113537
183751
228084
249867
346586
448404
727199
688125
1049209
1294878

Sr No

i)
ii)
iii)
iv)
v)
vi)
vii)
viii)
ix)
x)
xi)
xii)
xiii)
xiv)
xv)
xvi)
xvii)
xviii)
xix)
xx)
xxi)

Item Description

Unit

Lowering, laying, jointing in position following CIDF Reflux,


butterfly valves and sluice valves including cost of all labors
jointing material including nutbolts and giving satisfactory
hydraulic testing etc complete ( Rates for all class of valves )

50 mm
65 mm
80 mm
100 mm
125 mm
150 mm
200 mm
250 mm
300 mm
350 mm
400 mm
450 mm
500 mm
600 mm
700 mm
750 mm
800 mm
900 mm
1000 mm
1100 mm
1200 mm to 1500 mm

Providing and supplying Air valve as per IS 14845-2000 and


MJP Std Specification of approved make and quality of
following dia including all taxes ( Central and local ) rly frieght
inspection charges unloading from rly wagon loading in to
truck transportatin upto Dept store/ site unloading and stacking
etc complete

Air Valve Single Ball Flanged / Screwed Type - PN -1.0

No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No

689
1036
1440
1881
2342
2957
3076
4008
4158
5124
6182
7354
7616
8083
8714
9598
11438
12136
14307
16521
18153

615
741
1022
1116
1228
1349

12/15 MM

No

2
3

20 mm

No

25 mm

No

32 mm

No

40 mm

No

50 mm

No

Rate ( in Rs.)
2012-2013

Air Valve Single Ball Flanged / Screwed Type - PN -1.6

12/15 mm

No

20 mm

No

25 mm

No

32 mm

No

40 mm

No

50 mm

No

719
1022
1228
1324
1418
1851

Sr No

Item Description

Providing and supplying Air Valves as per IS-10845 and MJPs


standard specifications double orifice type combined with screw down
isolating valve, small orifice elastic ball resting on a gun metal orifice
nipple, large orifice vulcanite ball seating on moulded seat ring, inlet
face and drilled, including all taxes (Central and local), insurance,
third party inspection charges, loading, unloding, transportatoin upto
departmental stores / site, etc. complete.

A
a

With Third Party Inspection

Unit

a) Air Valve Double Ball Flanged Type - PN -1

50 mm

No

65 mm

No

80 mm

No

50 mm

No

65 mm

No

80 mm

No

Providing and supplying Air Valves as per IS-10845 and MJPs


standard specifications double orifice type combined with isolating
sluice valve, mounted in horzontal position and operated by wheel
gearing, small orifice elastic ball resting on a gun metal orifice nipple,
large orifice vulcanite ball seating on moulded seat ring, inlet face
and drilled, including all taxes (Central and local), insurance, third
party inspection charges, loading, unloading, transportation upto
departmental
store / site, etc. complete.

A
a

With Third Party Inspection


100 mm

No

150 mm

No

200 mm

No

100 mm

No

150 mm

No

200 mm

No

Providing and supplying Kinetic Double Orifice type Air Valves as per
MJPs standard specifications combined with screw down isolating
valve, small orifice elastic ball resting on a gun metal orifice nipple,
large orifice vulcanite ball seating on moulded seat ring, inlet face
and drilled, including all taxes (Central and local), insurance, third
party inspection charges, loading, unloading, transportation upto
departmental stores / site, etc. complete.

A
a

With Third Party Inspection

14617
20593
34633

a) Kinetic Air Valve Flanged Type - PN -1.

40 mm

No

50 mm

No

80 mm

No

9561
17425
29304

Air Valve Double Ball Flanged Type - PN -1.6

1
3

7515
8509
10530

Air Valve Double Ball Flanged Type - PN -1

5673
6619
7561

a) Air Valve Double Ball Flanged Type - PN -1.6

Rate ( in Rs.)
2012-2013

9516
11729
15304

a) Kinetic Air Valve Flanged Type - PN -1.6.

40 mm

No

50 mm

No

80 mm

No

11280
13903
18176

Sr No

Item Description

Unit

Providing and supplying Kinetic Double Orifice type Air Valves as per
MJPs standard specifications having small orifice elastic ball resting
on a gun metal orifice nipple, large orifice vulcanite ball seating on
moulded seat ring,with built-in Kinetic features, isolatintg sluice valve
mounted in horizontal position and operated by wheel gearing, inlet
face and drilled, including all taxes (Central and local), insurance,
third party inspection charges, loading, unloding, transportation upto
departmental stores / site, etc. complete.

No

A
a

With Third Party Inspection


a) Kinetic Air Valve Flanged Type - PN -1.

100 mm

No

150 mm

No

200 mm

No

100 mm

No

150 mm

No

200 mm

No

10

24427
45993
67161

Lowering, laying and fixing in proper alignment and position all types
of C.I. air valves as directed by Engineer-in-charge including cost of
conveyance from stores to site of work, cost of all material and giving
satisfactory hydraulic testing, etc. complete. (for all class of valves).
Air Valve Single Ball (PN-1 and PN - 1.6)

15 mm

No

20 mm

No

25 mm

No

32 mm

No

40 mm

No

50 mm

No

65 mm

No

80 mm

No

100 mm

No

10

125 mm

No

11

150 mm

No

12

200 mm

No

20610
38804
56659

a) Kinetic Air Valve Flanged Type - PN -1.6

1
3

Rate ( in Rs.)
2012-2013

110
140
180
199
213
231
243
255
285
345
383
421

Air Valve Double Ball (PN-1 and PN - 1.6)

15 mm

No

20 mm

No

25 mm

No

32 mm

No

40 mm

No

50 mm

No

65 mm

No

80 mm

No

100 mm

No

10

125 mm

No

11

150 mm

No

12

200 mm

No

120
149
180
205
238
275
317
379
400
441
603
664

Sr No

Item Description

Unit

Kinetic Air Valve (PN-1 and PN - 1.6)

40 mm

No

50 mm

No

65 mm

No

80 mm

No

100 mm

No

125 mm

No

150 mm

No

200 mm

No

11

Providing erecting Cast Steel/ Spheroidal Graphite (S.G) Iron D/F


Sluice Valves / Butterfly Valves with jointing to pipe work (including all
hardware and packing) water works quality, having non-rising spindle
with hand wheel and without bypass arrangement, spindle of
stainless steel as per requirement, excluding C. C. foundation /
structural steel support.

A
a

With Third Party Inspection

For Rating Class 150 (Working Pressure 20 kg/cm2 and Test


Pressure 30 kg/cm2) a) Sluice Valves.
80 mm dia

No

100 mm dia

No

150 mm dia

No

200 mm dia

No

250 mm dia

No

300 mm dia

No

350 mm dia

No

400 mm dia

No

450 mm dia

No

10

500 mm dia

No

11

600 mm dia

No

b).Butterfly Valves

300 mm dia

No

350 mm dia

No

400 mm dia

No

450 mm dia

No

500 mm dia

No

600 mm dia

No

12

Providing erecting Cast Steel D/F Sluice Valves with jointing to pipe
work (including all hardware and packing) water works qualityhaving
non-rising spindle with hand wheel and without bypass arrangement,
spindle of stainless steel as per requirement, excluding C. C.
foundation / structural steel support.

With Third Party Inspection ( Without byepass arrangement)

For Rating Class 300 (Working Pressure 52 kg/cm2 and Test


Pressure 78 kg/cm2). Sluice Valves
80 mm dia

Rate ( in Rs.)
2012-2013

No

100 mm dia

No

150 mm dia

No

200 mm dia

No

250 mm dia

No

273
315
345
379
417
455
652
711

14656
19540
29311
45713
65786
84173
112230
187281
255524
300616
343203
105843
112835
126737
135014
156289
175884

15776
24908
37976
59558
64292

Sr No

Item Description

Unit

300 mm dia

No

350 mm dia

No

400 mm dia

No

450 mm dia

No

10

500 mm dia

No

11

600 mm dia

No

300 mm dia

No

350 mm dia

No

400 mm dia

No

450 mm dia

No

500 mm dia

No

600 mm dia

No

Providing erecting Cast Steel /Spheroidal Graphite (S.G.) Iron D/F


Reflux Valves Single Door with jointing to pipe work (including all
hardware and packing) water works quality with jointing to pipe
without bypass arrangement, with gunmental seats excluding C. C.
foundation / structural steel support.
With Third Party Inspection

For Rating Class 150 (Working Pressure 20 kg/cm2 and Test


Pressure 30 kg/cm2).
80 mm dia

13

No

100 mm dia

No

150 mm dia

No

200 mm dia

No

250 mm dia

No

300 mm dia

No

14

10227
15661
26530
50442
87831
115713

For Rating Class 300 (Working Pressure 52 kg/cm2 and Test


Pressure 78 kg/cm2)
With Third Party Inspection
80 mm dia

No

100 mm dia

No

150 mm dia

No

200 mm dia

No

250 mm dia

No

300 mm dia

No

129129
137659
154619
164717
190673
214579

Providing erecting Cast Steel D/F Reflux Valves Single door with
jointing to pipe work (including all hardware and packing) water works
quality with jointing to pipe without bypass arrangement, with
gunmetal seat excluding C. C. foundation / structural steel support.

15

108382
182788
266657
321057
500178
756005

Butterfly Valves

Rate ( in Rs.)
2012-2013

15237
21477
35717
63275
114555
139478

Providing erecting Kinetic Double Orifice Cast Steel Air Valves with
an isolating Sluice Valve mounted in horizontal position operated by
wheel gear suitable for working pressure of Class-150 rating (20
kg/cm2).
With Third Party Inspection

80 mm dia

No

100 mm dia

No

150 mm dia

No

200 mm dia

No

29546
41185
78920
102014

Sr No

Item Description

16

Providing erecting Kinetic Double Orifice Cast Steel Air Valves with
an isolating Sluice Valve mounted in horizontal position operated by
wheel gear suitable for working pressure of Class 300 rating (52
kg/cm2)
With Third Party Inspection

Unit

80 mm dia

No

100 mm dia

No

150 mm dia

No

200 mm dia

No

17

Foundation on Murun and Harder Strata.


upto 150 mm dia

No

200 to 400 mm dia

No

450 to 900 mm dia

No

1000 to 1200 mm dia

No

upto 150 mm dia

No

200 to 400 mm dia

No

450 to 900 mm dia

No

1000 to 1200 mm dia

No

A
a

Pressure relief valves Type - PN -1.


25 mm

No

40 mm

No

50 mm

No

80 mm

No

100 mm

No

125 mm

No

150 mm

No

200 mm

No

250 mm

No

300 mm

No

5492
6625
12616
15821

Providing and supplying C.I. D/F angle type spring loaded pressure
relief valves of approved make and quality including all taxes (Central
and local), octroi, inspection charges, transportatoin to departmental
stores, etc. complete.
With Third Party Inspection

10

4636
5431
11045
13870

Foundation in B. C. Soil or Any Other Soil.

18

35996
41148
96157
116071

Providing and fixing in position air valve shaft including providing and
fixing GI Medium Class or 6 mm thick M.S. pipe shaft 2.70 M long
over branch flange of air valve tee, providing PCC block of M-150
concrete 150 mm thick around the air valve tee including encasing of
vertical shaft in PCC M-150 as shown in type design together with
providing and making flanged joints wherever required and fixing of
air valve over the shaft excluding cost of air valve and branch flanged
air valve tee. etc. complete as per type design and as directed by
Engineer-in-charge for following diameters of pipe lines (type design
attached.)

Rate ( in Rs.)
2012-2013

4234
5517
7145
10837
15170
20684
23635
52194
73367
96757

Pressure relief valves Type - PN -1.6.

25 mm

No

40 mm

No

50 mm

No

80 mm

No

100 mm

No

5294
6893
8914
13543
18958

Sr No

Item Description

Unit

125 mm

No

150 mm

No

200 mm

No

250 mm

No

300 mm

No

10

19

Lowering, laying and fixing in proper alignment and position all types
of C.I. D/F angle type spring loaded pressure relief valves including
all cost of all material, labour, cost of conveyance from stores to site
of work and giving satisfactory hydraulic testing, etc. complete. (For
all class of valves.).
25 mm

No

40 mm

No

50 mm

No

80 mm

No

100 mm

No

125 mm

No

150 mm

No

200 mm

No

250 mm

No

10

300 mm

No

Rate ( in Rs.)
2012-2013

25849
29544
65238
91707
121226

206
273
316
378
415
462
652
712
831
949

Note : Only 85% rate is payable till satisfactiry hydraulic testing is given.

20

Cutting and champhering of pipes of following diameters including


cost of all materials and labour involved, etc. complete as directed by
Engineer-in-charge (for all class of pipes).
C.I. Pipes.

80 mm

No

100 mm

No

150 mm

No

200 mm

No

250 mm

No

300 mm

No

350 mm

No

400 mm

No

450 mm

No

10

500 mm

No

11

600 mm

No

12

700 mm

No

13

750 mm

No

14

800 mm

No

15

900 mm

No

16

1000 mm

No

21

33
39
59
76
109
129
131
167
194
232
283
333
398
435
479
521

Cutting and champhering of pipes of following diameters including


cost of all materials and labour involved, etc. complete as directed by
Engineer-in-charge (for all class of pipes).
A.C. Pipes.

80 mm

No

100 mm

No

150 mm

No

200 mm

No

11
13
21
22

Sr No

Item Description

Unit

250 mm

No

300 mm

No

350 mm

No

400 mm

No

450 mm

No

10

500 mm

No

11

600 mm

No

22

80 mm

No

100 mm

No

150 mm

No

200 mm

No

250 mm

No

300 mm

No

350 mm

No

400 mm

No

450 mm

No

10

500 mm

No

11

600 mm

No

12

700 mm

No

13

750 mm

No

14

800 mm

No

15

900 mm

No

16

1000 mm

No

80 mm

Set

100 mm

Set

125 mm

Set

150 mm

Set

39
43
60
102
133
187
214
298
325
444
615
1095
1138
1179
1705
2190

Sealing O Rings of SBR (for CID joints)

32
44
54
61
66
75
86

Providing and supplying I.S.I. mark rubber gasket suitable for C.I. or
D. I. pipe of all class for tyton joints including all taxes (Central and
local) inspection charges, transportation to departmental stores / site,
etc. complete.
S.B.R. Gaskets for C. I. / DI Pipes.

Rate ( in Rs.)
2012-2013

45
53
64
75

Flat Flanged Gaskets moulded out of SBR (For Flanged Joints).

80 mm

No

100 mm

No

125 mm

No

150 mm

No

200 mm

No

250 mm

No

300 mm

No

350 mm

No

400 mm

No

10

450 mm

No

11

500 mm

No

12

600 mm

No

82
109
129
177
219
307
326
393
487
532
623
838

Sr No

Item Description

23

Providing and fixing and jointing high proformance C I Air valve for
water combination type ( Kinetic Air Valve alongwith automatic air
valve ) double ball , double orifice with stainless steel ball tampar
proof air vent rolling sill machanism for air release and anyivaccum
application design for 16 Kg/Sqcm working pressure and tested for
20 Kg /Sqcm pressure ( Rate include cost of gasket, belt, nut and any
other material required for jointing and its transportation etc and
including all taxes and duties and excluding octroi ).etc complete.

C I Air valve PN 1.6


1
2
3
4
5

24

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

50 MM
80 MM
100 MM
150 MM

Unit

No
No
No
No
No

200 MM
Providing and supplying I.S.I. mark EPDM rubber gasket suitable for
C.I. or D. I. pipe of all class for tyton joints including all taxes (Central
and local) inspection charges, transportation to departmental stores /
site, etc. complete.
80 mm.
100 mm.
150 mm.
200 mm.
250 mm.
300 mm.
350 mm.
400 mm.
450 mm.
500 mm.
600 mm.
700 mm.
750 mm.
800 mm.
900 mm.
1000 mm

No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.
No.

Rate ( in Rs.)
2012-2013

9513
13201
21226
35528
43035

46
48
70
117
160
212
247
338
378
500
703
1320
1383
1688
2178
2530

Section - I - ( XIII ) - Mechanical Joints/Fittings


Sr No

Item Description

Unit

Rate
( in Rs.)
2012-2013

1302
1419
1786
2555
3310
4993
5589
7372
9623
11295
14193
18200
24823
30164

Manufacturing,Suppling
of
C.I
mechanical
compression
flanged/socket Tail Pieces (Popularly known as IT.M flange/socket tail
piece) suitable for making flanged connection with the plain barrel of
C.I. spun pipes (As per I.S. 1536/2001) & D.I. pipes (As per I.S.
8329/2000) The tail piece to be supplied complete with sealing rubber
gasket of S.B.R.cast iron follower glands & mild steel nut-bolts.The
whole assembly should be mechanically & hydraulically tested to the
provision as laid down in I.S. 1538/1993. The rates are inclusive of
cost of material,forwarding charges,saletax, loading, transportation &
unloading at departmental store. etc complete as directed.

80 mm

No

100 mm

No

125 mm

No

150 mm

No

200 mm

No

250 mm

No

300 mm

No

350 mm

No

400 mm

No

10

450 mm

No

11

500 mm

No

12

600 mm

No

13

700 mm

No

750 mm

No

14

Manufacturing,Suppling & delivery of C.I mechanical compression


coller coupling (Popularly known as fifty T.M. coller coupling) ) suitable
for C.I. spun pipes (As per I.S. 1536/2001) & D.I. pipes (As per I.S.
8329/2000) complete with sealing rubber gasket of S.B.R,cast iron
follower glands & mild steel nut-bolts.The whole assembly should be
mechanically & hydraulically tested to the provision as laid down in
I.S. 1538/1993. The rates are inclusive of cost of material,forwarding
charges,saletax, loading, transportation & unloading at departmental
store. etc complete as directed.

80 mm

No

100 mm

No

125 mm

No

150 mm

No

200 mm

No

250 mm

No

300 mm

No

350 mm

No

400 mm

No

10

450 mm

No

11

500 mm

No

12

600 mm

No

13

700 mm

No

14

750 mm

No

784
841
1121
1512
1726
2767
3541
4364
6792
7626
10422
13000
16984
19928

Sr No

Item Description

Supply of C. I. Mechanical Joint Double Socket 90 (1/4) Bends as


dimensionally described in Table-14 of IS-13382/1992 complete with
sealing rubber gasket of SBR (dimensionally described in IS12820/1989) with cast iron follower gland and mild steel nut bolts
coated or otherwise protected from rusting and suitable for C. I.
pipes.
80 mm

Unit

No

100 mm

No

125 mm

No

150 mm

No

200 mm

No

250 mm

No

300 mm

No

350 mm

No

400 mm

No

10

450 mm

No

11

500 mm

No

12

600 mm

No

13

700 mm

No

14

750 mm

No

80 mm

No

100 mm

No

125 mm

No

150 mm

No

200 mm

No

250 mm

No

300 mm

No

350 mm

No

400 mm

No

10

450 mm

No

11

500 mm

No

12

600 mm

No

13

700 mm

No

14

750 mm

No

2231
2587
3022
4751
6305
9385
11422
18911
25775
32899
40940
57862
91333
103733

Supply of CI Mechanical joint Double Socket Socket 45 (1/8) Bends


as dimensionally described in Table -15 of IS - 13382/1992 complete
with sealing rubber gasket of S.B.R.(dimensionally described in IS12820/1989) with cast iron follower gland mild steel nut bolts coated
or otherwise protected from rusting and suitable for C. I. pipes.

Rate
( in Rs.)
2012-2013

Supply of C. I. Mechanical Joint Double Socket 22.5 (1/6) Bends as


dimensionally described in Table -16 of IS-13382/1992 complete with
sealing rubber gasket of SBR (dimensionally described in IS12820/1989) with cast iron follower gland and mild steel nut bolts
coated or otherwise protected from rusting and suitable for C. I.
pipes.
80 mm

No

100 mm

No

125 mm

No

150 mm

No

200 mm

No

2071
2306
2914
4002
5271
7733
9330
15564
19205
26788
29845
41324
58888
77879

1988
2213
2657
3757
4711

Sr No

Item Description

Unit

250 mm

No

300 mm

No

350 mm

No

400 mm

No

10

450 mm

No

11

500 mm

No

12

600 mm

No

13

700 mm

No

14

750 mm

No

Supply of CI Mechanical joint Double Socket 11.25 (1/32) Bends as


dimensionally described in Table -17 of IS - 13382/1992 complete
with sealing rubber gasket of S.B.R. dimensionally described in (IS12820/1989) with cast iron follower gland and mild steel nut bolts
coated or otherwise protected from rusting and suitable for C. I.
pipes.
80 mm

No

100 mm

No

125 mm

No

150 mm

No

200 mm

No

250 mm

No

300 mm

No

350 mm

No

400 mm

No

10

450 mm

No

11

500 mm

No

12

600 mm

No

13

700 mm

No

14

750 mm

No

Rate
( in Rs.)
2012-2013

7124
8599
13576
17404
22017
25658
33998
51142
56318

1969
2162
2348
3672
4522
6685
7407
11689
15834
19985
21784
29863
40258
44912

Supply of CI Mechanical joint All Socket Tees as dimenisonlly


described in Table -18 of IS - 13382/1992 complete with sealing
rubber gasket of S.B.R. dimensionally described in IS-12820/1989)
with cast iron follower gland and mild steel nut bolts coated or
otherwise protected from rusting and suitable for C. I. pipes.

80x80x80 mm dia

No

100x100x80 mm dia

No

100x100x100 mm dia

No

150x150x80 mm dia

No

150x150x100 mm dia

No

150x150x150 mm dia

No

200x200x80 mm dia

No

200x200x100 mm dia

No

200x200x150 mm dia

No

10

200x200x200 mm dia

No

11

250x250x80 mm dia

No

12

250x250x100 mm dia

No

13

250x250x150 mm dia

No

14

250x250x200 mm dia

No

15

250x250x250 mm dia

No

3016
3243
3596
5037
5108
6335
6075
6142
7316
8050
8555
8744
10435
11025
12366

Sr No

Item Description

Unit

16

300x300x80 mm dia

No

17

300x300x100 mm dia

No

18

300x300x150 mm dia

No

19

300x300x200 mm dia

No

20

300x300x250 mm dia

No

21

300x300x300 mm dia

No

Supply of CI Mechanical joint Double Stocket with Flanged Tees


dimenisonlly described in Table -19 of IS - 13382/1992 complete with
sealing rubber gasket of S.B.R. dimensionally described in IS12820/1989) with cast iron follower gland and mild steel nut bolts
coated or otherwise protected from rusting and suitable for C. I.
pipes.
80x80x80 mm dia

No

100x100x80 mm dia

No

100x100x100 mm dia

No

150x150x80 mm dia

No

150x150x100 mm dia

No

150x150x150 mm dia

No

200x200x80 mm dia

No

200x200x100 mm dia

No

200x200x150 mm dia

No

10

200x200x200 mm dia

No

11

250x250x80 mm dia

No

12

250x250x100 mm dia

No

13

250x250x150 mm dia

No

14

250x250x200 mm dia

No

15

250x250x250 mm dia

No

16

300x300x80 mm dia

No

17

300x300x100 mm dia

No

18

300x300x150 mm dia

No

19

300x300x200 mm dia

No

20

300x300x250 mm dia

No

21

300x300x300 mm dia

No

22

350x350x80 mm dia

No

23

350x350x100 mm dia

No

24

350x350x150 mm dia

No

25

350x350x200 mm dia

No

26

350x350x300 mm dia

No

27

350x350x350 mm dia

No

28

400x400x80 mm dia

No

29

400x400x100 mm dia

No

30

400x400x150 mm dia

No

31

400x400x200 mm dia

No

32

400x400x300 mm dia

No

33

400x400x400 mm dia

No

34

450x450x80 mm dia

No

35

450x450x100 mm dia

No

36

450x450x200 mm dia

No

Rate
( in Rs.)
2012-2013

9381
9591
12301
12708
13455
14849

2954
3241
3429
4892
5013
5970
5741
6124
7053
8087
8108
8532
10125
10595
10970
9519
9705
11205
11300
12470
15283
13314
14159
15234
17752
18187
20812
17404
18449
20541
20955
25253
28915
20758
21805
25573

Sr No

Item Description

Unit

37

450x450x300 mm dia

No

38

450x450x350 mm dia

No

39

450x450x450 mm dia

No

40

500x500x100 mm dia

No

41

500x500x250 mm dia

No

42

500x500x300 mm dia

No

43

500x500x400 mm dia

No

44

500x500x500 mm dia

No

45

600x600x100 mm dia

No

46

600x600x300 mm dia

No

47

600x600x400 mm dia

No

48

600x600x500 mm dia

No

49

600x600x600 mm dia

No

50

700x700x100 mm dia

No

51

700x700x200 mm dia

No

52

700x700x350 mm dia

No

53

700x700x400 mm dia

No

54

750x750x150 mm dia

No

55

750x750x250 mm dia

No

56

750x750x750 mm dia

No

Rate
( in Rs.)
2012-2013

32269
34049
36984
23355
31936
33086
39892
48162
33376
45831
52215
56505
69377
44235
51246
61922
66526
52759
60506
116081

Supply of CI Mechaincal joint Double Socket Reducers as described


in Table -21 of IS - 13382/1992 complete with sealing rubber gasket
of SBR dimensionally described in IS-12820/1989) with cast iron
follower gland and mild steel nut bolts coated or otherwise protected
from rusting and suitable for C. I. pipes.

100x80 mm dia

No

150x80 mm dia

No

150x100 mm dia

No

200x100 mm dia

No

200x150 mm dia

No

250x200 mm dia

No

250x150 mm dia

No

300x150 mm dia

No

300x200 mm dia

No

10

300x250 mm dia

No

11

350x200 mm dia

No

12

350x250 mm dia

No

13

350x300 mm dia

No

14

400x250 mm dia

No

15

400x300 mm dia

No

16

400x350 mm dia

No

17

450x300 mm dia

No

18

450x350 mm dia

No

19

450x400 mm dia

No

20

500x350 mm dia

No

21

500x400 mm dia

No

22

500x450 mm dia

No

2092
3292
3485
4011
4387
5994
5848
7372
7384
7510
10612
10646
10520
16029
14200
14295
17751
17740
17519
21339
21014
20483

Sr No

Item Description

Unit

23

600x400 mm dia

No

24

600x450 mm dia

No

25

600x500 mm dia

No

26

700x500 mm dia

No

27

700x600 mm dia

No

28

750x600 mm dia

No

29

750x700 mm dia

No

30

800x450 mm dia

No

31

800x700 mm dia

No

Rate
( in Rs.)
2012-2013

30985
30156
28313
42533
38601
45846
42377
63072
54144

Section - I - ( XIV ) - M.S.Pipes


Sr No

Item Description

Unit

Manufacturing, providing and supplying spirally welded / ERW/ SAW


/ fabricated M. S. pipes ( Commercial quality )including
procurements of plates, gas cutting to requried size rolling, tack
welding assembling in suitable lengths to form pipes, welding on
automatic welding machine and forming V edge on both ends of
pipes including all taxes (Central and local), railway freight,
insurance unloading from railway wagon, loading into truck, transport
to stores / site, unloading, stacking, etc, complete as per IS - 3589
and IS-5504 as applicable as per specifications (No negative
tolerance in thickness is permissible).
Dia of Pipe : 219.10 mm (O. D.)

4.80 mm thick

RMT

5.60 mm thick

RMT

6.40 mm thick

RMT

7.10 mm thick

RMT

7.90 mm thick

RMT

8.20 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

4.80 mm thick

RMT

5.60 mm thick

RMT

6.40 mm thick

RMT

7.10 mm thick

RMT

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

5.60 mm thick

RMT

6.40 mm thick

RMT

7.10 mm thick

RMT

7.90 mm thick

RMT

8.40 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

1912
2224
2533
2842
3071
3414
3641

Dia of Pipe : 323.90 mm (O. D.)

1527
1775
2021
2204
2477
2567
2717
2955

Dia of Pipe : 273.10 mm (O. D.)

Rate ( in Rs.)
2012-2013

2646
3016
3339
3706
3934
4071
4433

Dia of Pipe : 355.70 mm (O. D.)

5.60 mm thick

RMT

6.40 mm thick

RMT

7.10 mm thick

RMT

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

2909
3317
3672
4077
4480
4880

Sr No

Item Description

Unit

Dia of Pipe : 406.00 mm (O. D.)

5.60 mm thick

RMT

6.40 mm thick

RMT

7.10 mm thick

RMT

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

5.60 mm thick

RMT

6.40 mm thick

RMT

7.10 mm thick

RMT

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

5.60 mm thick

RMT

6.40 mm thick

RMT

7.10 mm thick

RMT

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

5.60 mm thick

RMT

6.40 mm thick

RMT

7.10 mm thick

RMT

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

5.60 mm thick

RMT

6.40 mm thick

RMT

7.10 mm thick

RMT

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

4600
5248
5816
6462
7105
7748
8148

Dia of Pipe : 610.00. mm (O. D.)

4177
4765
5278
5864
6447
7030
7392

Dia of Pipe : 559.00. mm (O. D.)

3751
4280
4741
5267
5788
6310
6635

Dia of Pipe : 508.00.mm (O. D.)

3327
3796
4203
4668
5130
5590
5878

Dia of Pipe : 457.00 mm (O. D.)

Rate ( in Rs.)
2012-2013

5024
5734
6353
7059
7764
8468
8906
10651

Dia of Pipe : 660.00. mm (O. D.)

5.60 mm thick

RMT

6.40 mm thick

RMT

7.10 mm thick

RMT

5439
6209
6881

Sr No

Item Description

Unit

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

5.60 mm thick

RMT

6.40 mm thick

RMT

7.10 mm thick

RMT

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

5.60 mm thick

RMT

6.40 mm thick

RMT

7.10 mm thick

RMT

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

5.60 mm thick

RMT

6.40 mm thick

RMT

7.10 mm thick

RMT

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

6711
7662
8492
9440
10387
11330
11919
14266

Dia of Pipe : 864.00. mm (O. D.)

5.60 mm thick

RMT

6.40 mm thick

RMT

7.10 mm thick

RMT

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

6288
7178
7955
8842
9727
10610
11161

Dia of Pipe : 813.00. mm (O. D.)

5863
6693
7417
8244
9069
9892
10405
12449

Dia of Pipe : 762.00. mm (O. D.)

7646
8411
9172
9648

Dia of Pipe : 711.00. mm (O. D.)

Rate ( in Rs.)
2012-2013

7135
8146
9030
10038
11045
12048
12675

Dia of Pipe : 914.00. mm (O. D.)

5.60 mm thick

RMT

6.40 mm thick

RMT

7.10 mm thick

RMT

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

7550
8622
9558
10624
11690
12754

Sr No

Item Description

10.00 mm thick

Unit

RMT

13418
7975
9107
10095
11223
12348
13473
14175

Dia of Pipe : 965.00. mm (O. D.)

5.60 mm thick

RMT

6.40 mm thick

RMT

7.10 mm thick

RMT

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

Dia of Pipe : 1016.00. mm (O. D.)

5.60 mm thick

RMT

6.40 mm thick

RMT

7.10 mm thick

RMT

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

5.60 mm thick

RMT

6.40 mm thick

RMT

7.10 mm thick

RMT

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

5.60 mm thick

RMT

6.40 mm thick

RMT

7.10 mm thick

RMT

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

9247
10559
11706
13016
14325
15631
16446

Dia of Pipe : 1168.00. mm (O. D.)

5.60 mm thick

RMT

6.40 mm thick

RMT

7.10 mm thick

RMT

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

8822
10075
11170
12419
13666
14911
15689

Dia of Pipe : 1118.00. mm (O. D.)

8398
9590
10632
11821
13008
14193
14932
17883

Dia of Pipe : 1067.00. mm (O. D.)

Rate ( in Rs.)
2012-2013

9661
11034
12234
13603
14970
16335
17188

Dia of Pipe : 1219.00. mm (O. D.)

6.40 mm thick

RMT

7.10 mm thick

RMT

11519
12772

Sr No

Item Description

Unit

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

9.50 mm thick

RMT

9.98 mm thick

RMT

10.00 mm thick

RMT

6.40 mm thick

RMT

7.10 mm thick

RMT

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

7.10 mm thick

RMT

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

9.50 mm thick

RMT

9.98 mm thick

RMT

7.10 mm thick

RMT

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

11.90 mm thick

RMT

12.00 mm thick

RMT

15986
17777
19567
21355
22472
26708
26930

Dia of Pipe : 1550.00. mm (O. D.)

10.00 mm thick

RMT

11.00 mm thick

RMT

ab

20637
21672

Dia of Pipe : 1524.00. mm (O. D.)

aa

14910
16581
18250
19917
20957
25114

Dia of Pipe : 1473.00. mm (O. D.)

12487
13846
15397
16946
18492
19459

Dia of Pipe : 1422.00. mm (O. D.)

18141
19049
19087

Dia of Pipe : 1321.00. mm (O. D.)

14201
15629
17055
17945
21498

Dia of Pipe : 1296.00. mm (O. D.)

Rate ( in Rs.)
2012-2013

22858
25127

Dia of Pipe : 1576.00. mm (O. D.)

9.50 mm thick

RMT

10.00 mm thick

RMT

22089
23243

Sr No

ac

Item Description

Unit

Dia of Pipe : 1626.00. mm (O. D.)

7.10 mm thick

RMT

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

ad

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

ag

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

ah

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

ai

21013
23131
25247
26569
31846

Dia of Pipe : 1850.00. mm (O. D.)

20427
22485
24542
25826
30956

Dia of Pipe : 1800.00. mm (O. D.)

19841
21840
23837
25084
30065

Dia of Pipe : 1750.00. mm (O. D.)

19254
21194
23132
24342
29175

Dia of Pipe : 1700.00. mm (O. D.)

af

17060
18973
20885
22793
23985
28748

Dia of Pipe : 1650.00. mm (O. D.)

ae

Rate ( in Rs.)
2012-2013

21599
23777
25951
27310
32737

Dia of Pipe : 1900.00. mm (O. D.)

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

22186
24422
26658
28053
33627

Sr No

aj

Item Description

Unit

Dia of Pipe : 1950.00. mm (O. D.)

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

ak

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

al

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

25117
27651
30181
31763
38080

Dia of Pipe : 2200.00. mm (O. D.)

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

ap

24530
27005
29477
31021
37190

Dia of Pipe : 2150.00. mm (O. D.)

ao

23946
26359
28771
30279
36299

Dia of Pipe : 2100.00. mm (O. D.)

an

23359
25713
28067
29537
35408

Dia of Pipe : 2050.00. mm (O. D.)

am

22773
25068
27362
28795
34517

Dia of Pipe : 2000.00. mm (O. D.)

Rate ( in Rs.)
2012-2013

25703
28297
30887
32505
38970

Dia of Pipe : 2250.00. mm (O. D.)

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

26290
28942
31592
33247
39861

Sr No

Item Description

Unit

Dia of Pipe : 2300.00. mm (O. D.)

aq
1

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

26877
29587
32297
33990
40751

Dia of Pipe : 2350.00. mm (O. D.)

ar
1

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

27462
30233
33002
34731
41643

Dia of Pipe : 2400.00. mm (O. D.)

as
1

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

28049
30879
33707
35474
42533

Dia of Pipe : 2450.00. mm (O. D.)

at
1

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

28635
31525
34413
36215
43424

Dia of Pipe : 2500.00. mm (O. D.)

au
1

7.90 mm thick

RMT

8.70 mm thick

RMT

9.50 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

16.00 mm thick

RMT

Rate ( in Rs.)
2012-2013

29222
32170
35117
36959
44314
58990

Manufacturing, providing and supplying spirally welded / ERW/ SAW


/ fabricated M. S. pipes ( Commercial quality ) including
procurements of plates, gas cutting to required size rolling, tack
welding assembling in suitable lengths to form pipes, welding on
automatic welding machine and forming V edge on both ends of
pipes including all taxes (Central and local), railway freight,
insurance unloading from railway wagon, loading into truck, transport
to stores / site, unloading, stacking, etc, complete as per IS - 3589
and IS-5504 as applicable as per specifications (No negative
tolerance in thickness is permissible).
Dia of Pipe : 200.00 mm (I. D.)

5.00 mm thick

RMT

6.00 mm thick

RMT

7.00 mm thick

RMT

8.00 mm thick

RMT

1522
1829
2151
2470

Sr No

Item Description

Unit

9.00 mm thick

RMT

10.00 mm thick

RMT

5.00 mm thick

RMT

6.00 mm thick

RMT

7.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

5.00 mm thick

RMT

6.00 mm thick

RMT

7.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

5.00 mm thick

RMT

6.00 mm thick

RMT

7.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

5.00 mm thick

RMT

6.00 mm thick

RMT

7.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

5.00 mm thick

RMT

6.00 mm thick

RMT

7.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

3376
4060
4748
5439
6131
6828

Dia of Pipe : 500.00 mm (I. D.)

5.00 mm thick

RMT

6.00 mm thick

RMT

7.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

3006
3616
4229
4845
5464
6085

Dia of Pipe : 450.00 mm (I. D.)

2634
3170
3709
4250
4795
5344

Dia of Pipe : 400.00 mm (I. D.)

2264
2725
3190
3657
4129
4601

Dia of Pipe : 350.00 mm (I. D.)

1892
2280
2670
3063
3460
3859

Dia of Pipe : 300.00 mm (I. D.)

2792
3117

Dia of Pipe : 250.00 mm (I. D.)

Rate ( in Rs.)
2012-2013

Dia of Pipe : 550.00 mm (I. D.)

3748
4506
5268
6032
6800
7570

Sr No

Item Description

Unit

5.00 mm thick

RMT

6.00 mm thick

RMT

7.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

5.00 mm thick

RMT

6.00 mm thick

RMT

7.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

5.00 mm thick

RMT

6.00 mm thick

RMT

7.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

5.00 mm thick

RMT

6.00 mm thick

RMT

7.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

5232
6288
7346
8408
9471
10538
12682

Dia of Pipe : 750.00 mm (I. D.)

5.00 mm thick

RMT

6.00 mm thick

RMT

7.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

4862
5841
6826
7813
8804
9797
11792

Dia of Pipe : 700.00 mm (I. D.)

4490
5397
6307
7220
8135
9054
10901

Dia of Pipe : 650.00 mm (I. D.)

4119
4951
5787
6626
7468
8313

Dia of Pipe : 600.00 mm (I. D.)

Rate ( in Rs.)
2012-2013

5604
6734
7866
9001
10140
11281
13572

Dia of Pipe : 800.00 mm (I. D.)

5.00 mm thick

RMT

6.00 mm thick

RMT

7.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

5974
7179
8384
9595
10807
12024

Sr No

Item Description

12.00 mm thick

Unit

RMT

14463
6346
7624
8905
10189
11475
12765
15353

Dia of Pipe : 850.00 mm (I. D.)

5.00 mm thick

RMT

6.00 mm thick

RMT

7.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

Dia of Pipe : 900.00 mm (I. D.)

5.00 mm thick

RMT

6.00 mm thick

RMT

7.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

5.00 mm thick

RMT

6.00 mm thick

RMT

7.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

5.00 mm thick

RMT

6.00 mm thick

RMT

7.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

7088
8515
9943
11376
12811
14249
17134

Dia of Pipe : 1000.00 mm (I. D.)

6717
8069
9424
10782
12143
13508
16244

Dia of Pipe : 950.00 mm (I. D.)

Rate ( in Rs.)
2012-2013

7458
8959
10463
11970
13479
14992
18026

Dia of Pipe : 1050.00 mm (I. D.)

5.00 mm thick

RMT

6.00 mm thick

RMT

7.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

7830
9405
10983
12563
14147
15733
18916

Sr No

Item Description

Unit

Dia of Pipe : 1100.00 mm (I. D.)

5.00 mm thick

RMT

6.00 mm thick

RMT

7.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

5.00 mm thick

RMT

6.00 mm thick

RMT

7.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

5.00 mm thick

RMT

6.00 mm thick

RMT

7.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

6.00 mm thick

RMT

7.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

6.00 mm thick

RMT

7.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

11632
13579
15531
17487
19444
23369

Dia of Pipe : 1350.00 mm (I. D.)

7.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

11186
13061
14938
16819
18702
22479

Dia of Pipe : 1300.00 mm (I. D.)

8942
10740
12541
14344
16151
17960
21588

Dia of Pipe : 1250.00 mm (I. D.)

8572
10296
12021
13751
15483
17218
20698

Dia of Pipe : 1200.00 mm (I. D.)

8201
9850
11501
13157
14815
16476
19808

Dia of Pipe : 1150.00 mm (I. D.)

Rate ( in Rs.)
2012-2013

Dia of Pipe : 1400.00 mm (I. D.)

14100
16126
18155
20186
24260

Sr No

Item Description

Unit

7.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

7.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

7.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

7.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

ac

7.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

ad

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

af

20281
22830
25382
30493

Dia of Pipe : 1750.00 mm (I. D.)

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

ag

19688
22161
24640
29602

Dia of Pipe : 1700.00 mm (I. D.)

16697
19094
21495
23898
28712

Dia of Pipe : 1650.00 mm (I. D.)

ae

16178
18501
20826
23156
27822

Dia of Pipe : 1600.00 mm (I. D.)

15659
17907
20159
22414
26931

Dia of Pipe : 1550.00 mm (I. D.)

15138
17313
19490
21672
26041

Dia of Pipe : 1500.00 mm (I. D.)

ab

14619
16720
18822
20928
25150

Dia of Pipe : 1450.00 mm (I. D.)

aa

Rate ( in Rs.)
2012-2013

Dia of Pipe : 1800.00 mm (I. D.)

20875
23499
26124
31384

Sr No

Item Description

Unit

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

ah

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

aj

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

16.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

16.00 mm thick

RMT

am

24438
27506
30577
36728
49066

Dia of Pipe : 2100.00 mm (I. D.)

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

16.00 mm thick

RMT

an

23844
26837
29834
35838
47878

Dia of Pipe : 2050.00 mm (I. D.)

23251
26170
29093
34947

Dia of Pipe : 2000.00 mm (I. D.)

al

22656
25502
28350
34057

Dia of Pipe : 1950.00 mm (I. D.)

ak

22062
24835
27609
33166

Dia of Pipe : 1900.00 mm (I. D.)

21469
24166
26866
32276

Dia of Pipe : 1850.00 mm (I. D.)

ai

Rate ( in Rs.)
2012-2013

25032
28174
31319
37618
50253

Dia of Pipe : 2150.00 mm (I. D.)

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

16.00 mm thick

RMT

25625
28842
32061
38509
51440

RMT

26219

ao
1

Dia of Pipe : 2200.00 mm (I. D.)


8.00 mm thick

Sr No

Item Description

Unit

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

16.00 mm thick

RMT

ap

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

16.00 mm thick

RMT

aq

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

16.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

16.00 mm thick

RMT

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

16.00 mm thick

RMT

28594
32182
35772
42962
57379

Dia of Pipe : 2450.00 mm (I. D.)

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

16.00 mm thick

RMT

au

28001
31514
35029
42072
56190

Dia of Pipe : 2400.00 mm (I. D.)

at

27407
30846
34288
41180
55002

Dia of Pipe : 2350.00 mm (I. D.)

as

26813
30177
33545
40290
53815

Dia of Pipe : 2300.00 mm (I. D.)

ar

29509
32804
39399
52627

Dia of Pipe : 2250.00 mm (I. D.)

Rate ( in Rs.)
2012-2013

29188
32849
36514
43853
58566

Dia of Pipe : 2500.00 mm (I. D.)

8.00 mm thick

RMT

9.00 mm thick

RMT

10.00 mm thick

RMT

12.00 mm thick

RMT

16.00 mm thick

RMT

29782
33517
37257
44743
59753

Section - I - ( XV ) - Fabrication of M.S.Pipes and Specials


Sr No

Item Description

Unit

Fabricating pipes from steel plates supplied free of cost and stacking
the same in the fabricators yard. The rate to include cutting the plate,
rolling, tack welding, assembling in suitable lengths to form pipes,
welding on automatic welding machines and forming V edge for both
ends of pipe.
5 To 8 mm

MT

8 To12 mm

MT

12 To 16 mm

MT

16 To 20 mm

MT

20 To 25 mm

MT

Rate
( in Rs.)
2012-2013

9005.00
7062.00
5297.00
4767.00
4590.00

Fabricating one piece cants, short pipes (shorter than one strake
length) from the steel plates supplied free of cost of and stacking the
same in fabricators yard. The rate to include cutting the plates, rolling,
tack welding either on automatic welding machine or manually and
forming V edge to both ends of pipes.
5 To 8 mm

MT

8 To12 mm

MT

12 To 25 mm

MT

12359.00
8121.00
5827.00

Fabricating composite bends from steel plates supplied free of cost


and stacking the same in the fabricators yard. The rate to include
cutting the plates, rolling, tacking drums, assembling the same to form
bend of suitable length, welding either on automatic welding machine
or manually and forming V edge to both ends of bend but the rate
excluding the circumferential butt welding required for assembling
cants to form necessary composite bend.
Circumferential butt welding will be paid seperately under Item No. 7.
(a) Howevere, the rate under this item will include the cost of
longitudinal butt welding of pipes strakes.
5 To 8 mm

MT

8 To12 mm

MT

12 To 16 mm

MT

16 To 25 mm

MT

Fabricating tapers from the steel plates, supplied free of cost and
stacking the same in the fabricators yard. The rate to include cutting
the plates, rolling, tack welding, welding either on automatic welding
machine or manually and forming V edge to both ends of tapers but
the rate excludes circuferential butt welding required for assembling
drums to form necessary tapers. Circumferential butt welding will be
paid for under Item No. 7 (a). Howerver, the rate under this includes
the longitudinal butt welding to form drums The rate shall also include
the cost of fabrication of stifferner rings and gussets and mounting the
same on tapers, tack and chain welding, etc. as directed by Engineerin-charge.

MT

14830.00
9887.00
7768.00
7239.00
11476.00

Sr No

Item Description

Fabricating specials and fixtures from steel materials supplied free of


cost (welding will be paid separately except for category vi (a) and (b)
below. The weight for payment under this item shall be caluculated on
the basis of finished material neglecting the bolt holes wherever
provided.)
i). Saddle pieces, loose stiffener rings, pressure type blank
flanges, ladders, platforms, and any other minor fixtures. The rate to
include cutting, bending, tack welding, etc. complete.

Unit

MT

Rate
( in Rs.)
2012-2013

4590.00

ii). Y branches, T branches. The rate to include cutting, bending,


tack welding etc. complete.
iii). Dished closures such as domes. The rate to include cutting,
cold pressing and tack welding etc. complete.
iv). Dished closures such as manhole cover. The rate to include
cutting cold pressing and tack welding only. The rate also to include
drilling holes including grinding wherever nesessary, with supply of
bolts, nuts, washers, etc. complete as per drawing.

MT

MT

15007.00
16067.00

v). Flat manhole covers. The rate to include cutting, tack welding.
The rate also to include drilling holes including grinding wherever
necessary with supply of bolts, nuts, washers, etc.complete as per
drawing.
vi , a). Flange rings below 40 mm. thick. The rate to include gas :
cutting, tack welding to form ring, drilling holes including grinding
wherever necessary etc. complete.
vi , b). Flange rings 40 mm.and above thick. The rate to include
gas cutting to tack welding to form ring, drilling holes including
grinding wherever necessary etc. complete.
vii , a). Machining of flange ringe for cut upto 2 mm. including
handling, assembling, alignment the ring on machine, etc. complete
as directed by Engineer-in-charge I)for thickness of flange ring below 40 mm.

MT

10417.00

MT

16949.00

MT

22069.00

Sq.m

ii) for thickness of flange ring 40 mm. and above.

Sq.m

vii b). Extra over and above (vii) (a) for machining beyond 2 mm.
for every additional cut of 2 mm. or part thereof.
i). Stress relieving of flange rings as specified and directed.

Sq.m

971.00
1483.00
741.00

Sq.m

3531.00

Each

67.00

300mm. dia.

Each

400 mm. dia.

Each

450 mm. dia.

Each

21887
31585
41085

ii). Plug plates 150 mm. dia. and the thickness of plate from 14 mm
to 25 mm as per drawing. The rate to include gas cutting, drilling
holes, cost of G. I. plugs, rolling to raquired curvature and therading,
etc. complete.
Providing, fabricating and fixing expansion joints for pipelines as per
the drawing. The rate to include machining the strakes and steel ring
as shown in the drawing and welding on either automatic welding
machine or manually, Rate includes plates and flats required for
expansion joint and all othr materials such as synthetic rubber, rubber
ring, etc. complete. including packing as per specifications, grease,
bolts and nuts, etc. including local handling, all types of taxes and
duties etc. complete.

9711.00
MT

Expansion joints suitable for pipe diameters.

1
2
3

Sr No

4
5
6
7
8
9
10
11

Item Description

Unit

500 mm. dia.

Each

600 mm. dia.

Each

700 mm. dia.

Each

750 mm. dia.

Each

800 mm. dia.

Each

Rate
( in Rs.)
2012-2013

Fabricating ring girder as per drawing and specifications from M.S.


channels, flats, plates, etc. supplied free of cost and assembling the
same on the ring girder strake and tack welding as per directions.

MT

55084
64711
80556
88773
103312
119952
143629
190757
5827

Fabricating ring girder supports (stools) as per drawing and


specifications complete with top plates, base plates, side flats for
fixing rollers wherever nescessary, grease box covers, rag bolts, grid
road etc. from steel material supplied free of cost and stacking the
same in fabricators yard.
Fabricating and assembling M.S. roller as per drawing. The rate to
include machining, assembling and fixing the same to the side flats
provided below the top plates of R.C. supports (stools) greasing
including providing anti-thteft measures M.S. rounds will be supplied
free of cost. All other materials such as bright stainless steel pins etc.
shall be supplied by the fabricator at his cost.

MT

7945.00

MT

17293

10

Blast cleaning the surface of the old or new pipeline internally to


remove all rust etc. complete, including providing sand, machinery,
labour, cutting of pipes at required places and rewelding the same etc,
complete as directed by Engineer-in-charge. (Pipes pieces if required
for rewelding of old pipeline shall be paid separately.)

Sq.m

77.00

11

Cleaning of old or new pipeline internally with mechanical cleaning


machine having steel scraper blades with required passes including
removing all rust, scaling etc. including cutting of pipes at required
places, rewelding the same incuding cost of all materials and labour,
etc, complete (Pipes pieces if required for rewelding of old pipeline
shall be paid separately.)

Sq.m

77.00

12

Cleaning of old pipeline internally by using swabbing method by


passing polyurethane foam Pig with required hydraulic pressure,
cutting of pipes at required places, rewelding the same including cost
of all materials and labour, etc. complete. (Pipe pieces if required for
rewelding of old pipeline shall be paid separately.)

Sq.m

91.00

Sq.m

91.00

Sq.m

25.00

900 mm. dia.

Each

1000 mm. dia.

Each

1200 mm. dia.

Each

Note : Water for this purpose shall be supplied by the department free
of cost at fixed point within 5 Kms. Lead and all arrangements for
filling section and creating hydraulic pressure on polyurethene pig
shall be done by contractor at his own cost.

13
14

Blast cleaning the surface of the old or new pipeline externally to


remove all rust including providing sand machinery. etc. complete as
directed by Engineer-in-charge.
Providing and applying primer and one coat of red oxide of
iron,paint, internally, to blast clened surface of the pipes.

Sr No

Item Description

Unit

Rate
( in Rs.)
2012-2013

15

Providing and applying primer and one coat of red oxide of


iron, paint, internally, including cleaning the surface of the pipes with
steel scrappers, wire brushes, and metal cleaning solution, etc.

Sq.m

43.00

16

Fabricating and fixing insulated flange rings assembly as per drawing


from steel material, supplied free of cost. The rate to include
fabrication of tail pipe (about 0.6 M long) fabrications of flange rings,
machining, drilling holes, including grinding wherever necessary and
welding, The rate above to include nuts, bolts, washers, etc. but shall
not include supply and fixing of backbite/PVC rings, cylinders and
rubber packing.
From 300mm.Upto 450mm. dia.

Each

Above 450 mm. Upto 750 mm. dia.

Each

Above 750 mm. Upto 1000 mm. dia.

Each

Above 1000 mm. Upto 1250 mm. dia.

Each

For pipe dia:

1
2
3
4
5
6

Above 1250 mm. Upto 1500 mm. dia.

Each

Above 1500 mm. Upto 2000 mm. dia.

Each

2138
4155
6184
10817
14722
17999

17

Providing and applying primer & one coat of red oxide of iron paint
externally to blast cleaned surface of the pipe etc complete

Sqm

27.50

18

Providing & applying primer and one coat of red oxide of iron paint
externally including cleaning the surface of the pipe with steel
scrapers wire brushes and metel cleaning solution etc complete

Sqm

60.00

19

Providing & applying covering coat of gray graphite of approved


quality including dusting the surface etc complete.

Sqm

31.00

20

Providing & applying one coat of zinc rich epoxy primer to the internal
surface of pipeline at site.

Sqm

66.00

21

Providing & applying primer first coat of interol 49W emaline 05/58
pipe coat or any other equivalent approved paint to the internal
surface of pipeline at site.
b) Second coat

Sqm

50.00

Sq.m

41.00

c)Third coat

Sq.m

40.00

Section - I - ( XVI ) - M.S.Pipes Laying


Sr No

Item Description

Lowering laying in position to correct line and level including M. S.


pipes with / without any outcoating on pedastals or chairs upon
prepared formation.The rate to include loading, unloading hoisting,
marginal cutting wherever required, assembling and tack welding, and
transportation upto 500 M. etc. completed as specified.

Unit

Rate
( in Rs.)
2012-2013

282
332
381
431
482

a)

5 mm to 8 mm thick.

Upto 250 mm. dia.

RMT

Above 250 mm. Upto 500 mm. dia.

RMT

Above 500 mm. Upto 750 mm. dia.

RMT

Above 750 mm. Upto 1000 mm. dia

RMT

Above 1000 mm. Upto 1250 mm. dia.

RMT

b)

Above 8 mm upto 12 mm thick.

From 750 mm. Upto 1000 mm. dia.

RMT

Above 1000 mm. Upto l250 mm. dia

RMT

Above 1250 mm. Upto 1500 mm. Dia

RMT

Above 1500 mm Upto 1750 mm. dia

RMT

Above 1750 mm. Upto 2000 mm dia

RMT

Above 2000 mm. upto 2250 mm dia

RMT

Above 2250 mm. upto 2500 mm dia

RMT

c)

Above 12 mm upto 16 mm thick.

From 2000 mm Upto 2250 mm dia

RMT

Above 2250 rnm. Uplo 2500 mm dia.

RMT

Above 2500 mm Upto 2750 mm dia

RMT

Above 2750 mm. Upto 3000 mm. dia.

RMT

Above 3000 mm. upto 3250 mm dia.

RMT

Above 3250 mm. Upto 3500 mm

RMT

6
d)

864
932
996
1060
1124
1189

Above 16 mm upto 20 mm thick

From 2500 mm Upto 2750 mm dia

RMT

Above 2750 mm Upto 3000 mm dia

RMT

Above 3000 mm upto 3250 mm dia

RMT

Above 3250 mm Upto 3500 mm did

RMT

Above 3500 mm Upto 3750 mm dia

RMT

Above 3750 mm upto 4000 mm dia

RMT

e)

574
640
706
774
840
906
974

1306
1378
1450
1522
1595
1668

Above 20 mm upto 25 mm thick

Above 3500 mm Upto 3750 mm dia

RMT

Above 3750 mm upto 4000 mm dia

RMT

1778
1880

Sr No

Item Description

Lowering laying in position to correct line and level including M. S.


specials with / without any outcoating such as distance pieces, straps,
bends, tapers, etc. on pedastals or chairs upon perpared formation in
trenches upon prepared formation.The rate to include loading,
unloading hoisting, marginal cutting wherever required, assembling
and tack welding, and transportation upto 500 M. etc. complete.

Unit

Rate
( in Rs.)
2012-2013

394
462
534
603
673

a)

5 mm to 8 mm thick.

Upto 250 mm. dia.

RMT

Above 250 mm. Upto 500 mm. dia.

RMT

Above 500 mm. Upto 750 mm. dia.

RMT

Above 750 mm. Upto 1000 mm. dia.

RMT

Above 1000 mm. Upto 1250 mm. dia.

RMT

b)

Above 8 mm upto 12 mm thick.

From 750 mm.Upto 1000 mm. dia.

RMT

Above 1000 mm. Upto 1250 mm. dia.

RMT

Above 1250 mm. Upto 1500 mm. dia.

RMT

Above 1500 mm. Upto 1750 mm. dia.

RMT

Above 1750 mm. Upto 2000 mm. dia.

RMT

Above 2000 mm. Upto 2250 mm. dia.

RMT

Above 2250 mm. Upto 2500 mm. dia.

RMT

c)

Above 12 mm upto 16 mm thick

From 2000 mm. Upto 2250 mm. dia.

RMT

Above 2250 mm. Upto 2500 mm. dia.

RMT

Above 2500 mm. Upto 2750 mm. dia.

RMT

Above 2750 mm. Upto 3000 mm. dia.

RMT

Above 3000 mm. Upto 3250 mm. dia.

RMT

Above 3250 mm. Upto 3500 mm. dia.

RMT

d)

From 2500 mm. Upto 2750 mm. dia.

RMT

Above 2750 mm. Upto 3000 mm. dia.

RMT

Above 3000 mm. Upto 3250 mm. dia.

RMT

Above 3250 mm. Upto 3500 mm. dia.

RMT

Above 3500 mm. Upto 3750 mm. dia.

RMT

Above 3750 mm. Upto 4000 mm. dia.

RMT

1796
1877
2031
2132
2232
2333

Above 20 mm upto 25 mm thick.

From 3500 mm. Upto 3750 mm. dia.

RMT

Above 3750 mm. Upto 4000 mm. dia.

RMT

1252
1304
1394
1483
1574
1664

Above 16 mm upto 20 mm thick.

e)

804
897
989
1082
1177
1269
1362

2488
2631

Lowering laying in position to correct line and level including M. S.


pipes with / without any outcoating, on pedestals or chairs upon piers,
trestles etc. The rate to include loading, unloading hoisting, marginal
cutting wherever required, assembling and tack welding, transportaion
upto 500 M. etc. complete.

a)

5 mm to 8 mm thick.

Upto 250 mm. dia.

RMT

Above 250 mm. Upto 500 mm. dia.

RMT

337
396

Sr No

Item Description

Unit

Rate
( in Rs.)
2012-2013

457
517
578

Above 500 mm. Upto 750 mm. dia.

RMT

bove 750 mm. Upto 1000 mm. dia.

RMT
RMT

Above 1000 mm. Upto 1250 mm. dia.

b)

Above 8 mm upto 12 mm thick.

From 750 mm.Upto 1 000 mm. dia.

RMT

Above 1000 mm. Upto 1250 mm. dia.

RMT

Above 1250 mm. Upto 1500 mm. dia.

RMT

Above 1500 mm. Upto 1750 mm. dia.

RMT

Above 1750 mm. Upto 2000 mm. dia.

RMT

Above 2000 mm. Upto 2250 mm. dia.

RMT

Above 2250 mm. Upto 2500 mm. dia.

RMT

c)

Above 12 mm upto 16 mm thick.

From 2000 mm. Upto 2250 mm. dia.

RMT

Above 2250 mm. Upto 2500 mm. dia.

RMT

Above 2500 mm. Upto 2750 mm. dia.

RMT

Above 2750 mm. Upto 3000 mm. dia.

RMT

Above 3000 mm. Upto 3250 mm. dia.

RMT

Above 3250 mm. Upto 3500 mm. dia.

RMT

6
d)

Above 2500 mm. Upto 2750 mm. dia.

RMT

Above 2750 mm. Upto 3000 mm. dia.

RMT

Above 3000 mm. Upto 3250 mm. dia.

RMT

Above 3250 mm. Upto 3500 mm. dia.

RMT

Above 3500 mm. Upto 3750 mm. dia.

RMT

Above 3750 mm. Upto 4000 mm. dia.

RMT

from 3500 mm. Upto 3750 mm. dia.

RMT

Above 3750 mm. Upto 4000 mm. dia.

RMT

5 mm to 8 mm thick.

Upto 250 mm. dia.

RMT

Above 250 mm. Upto 500 mm. dia.

RMT

Above 500 mm. Upto 750 mm. dia.

RMT

Above 750 mm. Upto 1000 mm. dia.

RMT

Above 1000 mm. Upto 1250 mm. dia.

RMT

2133
2256

Lowering and laying in position to correct line and level including M. S.


specials such as distance pieces, straps, bends, tapers, etc. on
pedestals or chairs up on piers or trestles. The rate to include loading,
unloading hoisting, marginal cutting wherever required, assembling
and tack welding, and including transportation upto 500 M. etc.
complete as specified.

a)

b)

1566
1653
1740
1826
1913
2001

Above 20 mm upto 25 mm thick.

994
1042
1194
1273
1350
1416

Above 16 mm upto 20 mm thick.

e)

689
768
848
928
1009
1089
1167

472
556
639
724
807

Above 8 mm upto 12 mm thick.

From 750 mm.Upto 1000 mm. dia.

RMT

Above 1000 mm. Upto 1250 mm. dia.

RMT

Above 1250 mm. Upto 1500 mm. dia.

RMT

Above 1500 mm. Upto 1750 mm. dia.

RMT

965
1076
1188
1299

Sr No

Item Description

Unit

Rate
( in Rs.)
2012-2013

1412
1525
1635

Above 1750 mm. Upto 2000 mm. dia.

RMT

Above 2000 mm. Upto 2250 mm. dia.

RMT

Above 2250 mm. Upto 2500 mm. dia.

RMT

c)

Above 12 mm upto 16 mm thick.

From 2000 mm. Upto 2250 mm. dia.

RMT

Above 2250 mm. Upto 2500 mm. dia.

RMT

Above 2500 mm. Upto 2750 mm. dia.

RMT

Above 2750 mm. Upto 3 000 mm. dia.

RMT

Above 3000 mm. Upto 3250 mm. dia.

RMT

Above 3250 mm. Upto 3500 mm. dia.

RMT

d)

Above 16 mm upto 20 mm thick.

From 2500 mm. Upto 2750 mm. dia.

RMT

Above 275Omm. Upto 3000 mm. dia.

RMT

Above 3000 mm. Upto 3250 mm. dia.

RMT

Above 3250 mm. Upto 3500 mm. dia.

RMT

Above 3500 mm. Upto 3750 mm. dia.

RMT

Above 3750 mm. Upto 4000 mm. dia.

RMT

e)

From 3500 mm. Upto 3750 mm. dia.

RMT

Above 3750 mm. Upto 4000 mm. dia.

RMT

5 mm to 8 mm thick.

Upto 250 mm. dia.

RMT

Above 250 mm. Upto 500 mm. dia.

RMT

Above 500 mm. Upto 750 mm. dia.

RMT

Above 750 mm. Upto 1000 mm. dia.

RMT

Above 1000 mm. Upto 1250 mm. dia.

RMT

289
340
391
442
493

Above 8 mm upto 12 mm thick.

From 750 mm.Upto 1000 mm. dia.

RMT

Above 1000 mm. Upto 1250 mm. dia.

RMT

Above 1250 mm. Upto 1500 mm. dia.

RMT

Above 1500 mm. Upto 1750 mm. dia.

RMT

Above 1750 mm. Upto 2000 mm. dia.

RMT

Above 2000 mm. Upto 2250 mm. dia.

RMT

Above 2250 mm. Upto 2500 mm. dia.

RMT

c)

2988
3157

Transporting within 500 meters,laying in position to correct line and


level M. S. pipes with / without any outcoating, on prepared bedding in
trenches including marginal cutting wherever required, assembling
tack welding the same. The rate to include loading, unloading,
hoisting, ect. complete as specified.

a)

b)

2195
2314
2437
2555
2679
2802

Above 20 mm upto 25 mm thick.

1503
1563
1672
1781
1889
1998

589
656
724
793
860
928
996

Above 12 mm upto 16 mm thick

From 2000 mm. Upto 2250 mm. dia.

RMT

Above 2250 mm. Upto 2500 mm. dia.

RMT

Above 2500 mm. Upto 2750 mm. dia.

RMT

Above 2750 mm. Upto 3000 mm. dia.

RMT

Above 3000 mm. Upto 3250 mm. dia.

RMT

915
955
1021
1087
1153

Sr No

6
d)

Item Description

Above 3250 mm. Upto 3500 mm. dia.

Unit

Rate
( in Rs.)
2012-2013

RMT

1219
1334
1408
1483
1558
1632
1708

Above 16 mm upto 20 mm thick.

From 2500 mm. Upto 2750 mm. dia.

RMT

Above 2750 mm. Upto 3000 mm. dia.

RMT

Above 3000 mm. Upto 3250 mm. dia.

RMT

Above 3250 mm. Upto 3500 mm. dia.

RMT

Above 3500 mrn. Upto 3750 mm. dia.

RMT

Above 3750 mm. Upto 4000 mm. dia.

RMT

e)

Above 20 mm upto 25 mm thick.

From 3500 mm. Upto 3750 mm. dia.

RMT

Above 3750 mm. Upto 4000 mm. dia.

RMT

Transporting within 500 meters,laying in position to correct line and


level M. S. specials pipes with / without any outcoating, such as
distance pieces, straps, bends, tapers, etc. on prepared bedding in
trenches including marginal cutting wherever required, assembling
tack welding, the same. The rate to including loading, unloading,
hoisting, ect. complete as specified.

a)

5 mm to 8 mm thick.

Upto 250 mm. dia.

RMT

Above 250 mm. Upto 500 mm. dia.

RMT

Above 500 mm. Upto 750 mm. dia.

RMT

Above 750 mm. Upto 1000 mm. dia.

RMT

Above 1000 mm. Upto 1250 mm. dia.

RMT

b)

From 750 mm.Upto 1000 mm. dia.

RMT

Above 1000 mm. Upto 1250 mm. dia.

RMT

Above 1250 mm. Upto 1500 mm. dia.

RMT

Above 1500 mm. Upto 1750 mm. dia.

RMT

Above 1750 mm. Upto 2000 mm. dia.

RMT

Above 2000 mm. Upto 2250 mm. dia.

RMT

Above 2250 mm. Upto 2500 mm. dia.

RMT

824
919
1013
1109
1288
1345
1394

Above 12 mm upto 16 mm thick.

From 2000 mm. Upto 2250 mm. dia.

RMT

Above 2250 mm. Upto 2500 mm. dia.

RMT

Above 2500 mm. Upto 2750 mm. dia.

RMT

Above 2750 mm. Upto 3000 mm. dia.

RMT

Above 3000 mm. Upto 3250 mm. dia.

RMT

Above 3250 mm. Upto 3500 mm. dia.

RMT

d)

406
475
548
618
691

Above 8 mm upto 12 mm thick.

c)

1817
1922

1282
1387
1428
1521
1616
1708

Above 16 mm upto 20 mm thick.

From 2500 mm. Upto 2750 mm. dia.

RMT

Above 2750 mm. Upto 3000 mm. dia.

RMT

Above 3000 mm. Upto 3250 mm. dia.

RMT

Above 3250 mm. Upto 3500 mm. dia.

RMT

Above 3500 mm. Upto 3750 mm. dia.

RMT

Above 3750 mm. Upto 4000 mm. dia.

RMT

1855
1972
2078
2181
2286
2391

Sr No

e)

Item Description

Unit

Rate
( in Rs.)
2012-2013

2543
2692

Above 20 mm upto 25 mm thick.

From 3500 mm. Upto 3750 mm. dia.

RMT

Above 3750 mm. Upto 4000 mm. dia.

RMT

a)

Welding in all positions with required number of runs, for M. S. pipes


internally and / or externally including gauging wherever necessary,
fixing appurtenances and other accessories in connection with pipe
laying work as per specification.
Butt Joints : Plate thickness:

4 mm.

RMT

5 mm.

RMT

6 mm.

RMT

7 mm.

RMT

8 mm.

RMT

10mm.

RMT

12mm.

RMT

14mm.

RMT

16mm.

RMT

10

18mm.

RMT

11

20 mm.

RMT

12

22 mm.

RMT

13

25 mm.

RMT

b)

Lap joints with convex fillet welds Lag Lengths:

5 mm.

RMT

6 mm.

RMT

8 mm.

RMT

10mm.

RMT

12mm.

RMT

14mm.

RMT

16mm.

RMT

18mm.

RMT

20 mm.

RMT

10

22 mm.

RMT

11

25 mm.

RMT

8
1

131
198
465
519
651
798
854
1018
1232
1334
1599
2008
2725

Shifiting and aligning ring girders including removing tack welds and retacking in the correct position etc. complete as per specification for the
pipes of following diameter.
From 1000 mm, Upto 1250 mm. dia.

RMT

Above 1250 mm. Upto 1500 mm. dia.

RMT

Above 1500 mm. Upto 1750 mm. dia.

RMT

Above 1750 mm. Upto 2000 mm. dia.

RMT

Above 2000 mm. Upto 2250 mm. dia.

RMT

Above 2250 mm. Upto 2500 mm. dia.

RMT

Above 2500 mm. Upto 2750 mm. dia.

RMT

Above 2750 mm. Upto 3000 mm. dia.

RMT

Above 3000 mm. Upto 3250 mm. dia.

RMT

10

Above 3250 mm. Upto 3500 mm. dia.

RMT

183
234
310
347
519
705
776
941
1062
1419
1723

355
435
513
592
670
749
827
908
987
1065

Sr No

Item Description

Unit

Rate
( in Rs.)
2012-2013

1144
1229

11

Above 3500 mm. Upto 3750 mm. dia.

RMT

12

Above 3750 mm. Upto 4000 mm. dia.

RMT

Transporting within 500 meters and fixing in position stools, base


plates, roller sets, grease box covers, etc. including welding wherever
necessary. The rate also to include fixing stools, base plates, etc. in
true line and level, connecting the base plate to anchor bolts by flush
welding including cutting the bolts, if required, assembleng and
aligning C. I. or M. S. roller sets of any size including oiling, greasing,
etc. The rate also to include grouting anchor bolts, welding of two
halves of grease box covers as directed by Engineer-in-charge, for
pipes of following dia.

From 1000 mm, Upto 1250 mm. dia.

Each

Above 1250 mm. Upto 1500 mm. dia.

Each

Above 1500 mm. Upto 1750 mm. dia.

Each

Above 1750 mm. Upto 2000 mm. dia.

Each

Above 2000 mm. Upto 2250 mm. dia.

Each

Above 2250 mm. Upto 2500 mm. dia.

Each

Above 2500 mm. Upto 2750 mm. dia.

Each

Above 2750 mm. Upto 3000 mm. dia.

Each

Above 3000 mm. Upto 3250 mm. dia.

Each

10

Above 3250 mm. Upto 3500 mm. dia.

Each

11

Above 3500 mm. Upto 3750 mm. dia.

Each

12

Above 3750 mm. Upto 4000 mm. dia.

Each

10

1299
1405
1511
1617
1723
1829
1935
2041
2147
2253
2378
2463

Transporting within 500 meters and aligning, fixing in position and tack
welding expansion joints suitable for pipeline of diameters.

From 1000 mm, Upto 1250 mm. dia.

Each

Above 1250 mm. Upto 1500 mm. dia.

Each

Above 1500 mm. Upto 1750 mm. dia.

Each

Above 1750 mm. Upto 2000 mm. dia.

Each

Above 2000 mm. Upto 2250 mm. dia.

Each

Above 2250 mm. Upto 2500 mm. dia.

Each

Above 2500 mm. Upto 2750 mm. dia.

Each

Above 2750 mm. Upto 3000 mm. dia.

Each

Above 3000 mm. Upto 3250 mm. dia.

Each

10

Above 3250 mm. Upto 3500 mm. dia.

Each

11

Above 3500 mm. Upto 3750 mm. dia.

Each

12

Above 3750 mm. Upto 4000 mm. dia.

Each

4395
4558
4723
4887
9238
9445
9650
9793
10063
10270
10474
10682

Sr No

Item Description

11

Transporting within 500 meters aligning and fixing in position and tack
welding only, including marginal cutting, supplying and providing
rubber packing etc. where necessary.
Minor fixtures such as manhole cover, pressure and non-pressure
type blank flanges, loose rings, small pipes to form saddle bypass
arrangement, plug plates, ladders, platform, stiffener rings, etc.

a)

b)

12

Minor fixtures such as tees, domes, Y branches, insulating flange


ring assembly, etc
Gas cutting (either square cut or V cut) pipes, plates, etc. of thickness

Unit

Rate
( in Rs.)
2012-2013

MT

7868

MT

3997

upto 5 mm.

RMT

above 5 mm. Upto 10 mm.

RMT

Above 10 mm. Upto 14 mm.

RMT

Above 14 mm. Upto 18 mm.

RMT

Above 18 mm. Upto 22 mm.

RMT

Above 22 mm.

RMT

13

59
84
109
124
172
230

Gas cutting holes upto 50 mm dia (for plugs)


Thickness of shell

5 mm. to 12 mm

No

Above 12 mm

No

Providing M.S. bar mesh prepared out of 16 mm dia M.S. bar at 15


cm. c/c both ways, welded to flanged ring including tack welding of
bars and fixing the same with nuts and bolts on open faces of outlet /
inlet pipes in the sump or reservoir, etc. complete as directed by
Engineer-in-charge.
Providing permanent test points on the pipe line as per drawing and
as directed by Engineer-in-charge including providing and fixing sluice
valves, road boxes for sluice valves of size 80 mm to 250 mm in one
brick masonry chamber 300 mm x 300 mm clear C. M. 1:5 with 12 mm
thick 1:3 cement plaster both inside and outside on M-100 C.C. , 150
mm thick etc. complete as specified and directed.

Sq.m

65
90
1192

No

2675

16

Supplying transporting, the S.P. fire hydrants including duck foot bend,
S.V. and S.V. road box, painting the hydrant,fixing the saddle piece,
supplying, and laying required lenght of C.I. pipeline and jointing the
same spun yarn, molten lead including caulking, fixing the S.V. road
box in one brick masonry chamber in 1:5 C.M. with 12 mm thick 1:3
cement plaster both inside and outside on 1:3:6: C.C.150 mm thick
etc, complete specified and directed. [As per I.S.900/1965 Revised]

No

13090

17

Hydraulic testing of M.S. pipeline to specified pressure including cost


of all materials and labour and water for testing for the lenght upto
1km., using reciprocating type pumps which should be able to provide
specified test pressure gauges and other necessary equipments,
labour, operation charges, etc. required for testing. The rate under this
item shall also include cost of retesting, if necessary.

37248
37303
37389

14

15

Upto 600mm.dia.(I.D.)

Km

Above 600 mm. upto 750 mm. dia. (l.D.)

Km

Above 750 mm. upto 900 mm. dia. (l.D.)

Km

Sr No

Item Description

Unit

Rate
( in Rs.)
2012-2013

37518
37646
37899
38272
38898
39354
39809

Above 900 mm. upto 1050 mm. dia. (l.D.)

Km

Above 1050 mm. upto 1200 mm. dia. (l.D.)

Km

Above 1200 mm. upto 1500 mm. dia. (l.D.)

Km

Above 1500 mm. upto 1800 mm. dia. (l.D.)

Km

Above 1800 mm. upto 2250 mm. dia. (l.D.)

Km

Above 2250 mm. upto 2500 mm. dia. (l.D.),

Km

10

Above 2500 mm. dia. (l.D.)

Km

Extra over initial KM


1

Upto 600mm.dia.(I.D.)

Km

Above 600 mm. upto 750 mm. dia. (l.D.)

Km

Above 750 mm. upto 900 mm. dia. (l.D.)

Km

Above 900 mm. upto 1050 mm. dia. (l.D.)

Km

Above 1050 mm. upto 1200 mm. dia. (l.D.)

Km

Above 1200 mm. upto 1500 mm. dia. (l.D.)

Km

Above 1500 mm. upto 1800 mm. dia. (l.D.)

Km

Above 1800 mm. upto 2250 mm. dia. (l.D.)

Km

18

Providing and applying with mechanical arrangement 1:3 proportion


cement sand gunite, 40 to 50 mm thick to M. S. pipe surface under 2.1
kg. per sqcm. to 2.80 kg. per sqcm. pressure including removing the
loose materials as directed by Engineer-in-charge and including
scrapping the surface with wire brushes, degreasing, cleaning by
compressed air and providing fixing BRC fabric no.14 as
reinforcement, curing for 21 days, disposing off the rebound materials
within a lead of 50 M, etc. complete as directed by Engineer-incharge.

Sq.m

189
270
402
531
684
1010
1528
2344
2919
3530
4167
416

19

Providing and applying pipe coating of fibres, coaltar and solvent


based rubber modified bituminous primer of density 0.92 gms/cu cm
and viscosity of 1000-2000 cps @ 150 gms/sqm followed by seven
layers(4mm thick) of polythene polymerised bitumen and polyester of
local 7 layers) pipe cost 4 mm should conform to requirement of IS10221 and AWWA C-203 for pre-fabricated tapes including covering
cost on pipe coating. Rates shall include cost of material coating and
wrapping over the pipes, handling charges, perparation of pipe
surface, all labour, material, etc. complete.] Note : Pipe coating is to
be done at laying worksite only.

Sq.m

448

20

Providing and applying with mechanical arrangement cement sand


gunite of 50 mm thickness to floors, walls, floor slabs or any other
structure under 2.1 kg. per sqcm. to 2.80 kg. per sqcm. pressure
including removing the loose materials on surface, cleaning with
comperssed air, degreasing, etc. including scaffolding and curing for
21 days, providing and fixing BRC fabric no. 14 but excluding cost of
reinforcement, if any and removing rebound materials within a lead of
50 M, etc. complete as directed by Engineer-in-charge (for GSRs and
buildings.)

Sq.m

363

Above 2250 mm. upto 2500 mm. dia. (l.D.),

Km

10

Above 2500 mm. upto 2750 mm. dia. (l.D.),

Km

11

Above 2750 mm. dia. (l.D.)

Km

Sr No

Item Description

Unit

Rate
( in Rs.)
2012-2013

21

Providing and applying with mechanical arrangement cement sand


gunite of 50 mm thickness to floors, walls, roof slabs or any other
structure under 2.1 kg. per sqcm. to 2.80 kg. per sqcm. pressure
including removing the loose materials on surface, cleaning with
compressed air, degreasing, etc. including scaffolding and curing for
21 days, providing and fixing BRC fabric no. 14 but excluding cost of
reinforcement, if any and removing rebound materials within a lead of
50 M, for staging and bottom of bottom slab, etc. complete as directed
by Engineer-in-charge (for RCC ESRs)

Sq.m

476

22

Providing and making inner cement mortar lining to M.S. pipes with
mechanical devices in cement mortar 1:1 proportion, including cost of
all materials, labour, special sand required, machinery, power
generation, all equipments and taking necessary access openings and
manholes, cuts at suitable intervals as directed by Engineer-in-charge
and rewelding the same after done with doubler plates pipes including
necessary excavation, refilling concerte breaking and remaking if any,
breaking guniting and remaking the same, repainting wherever
required with epoxy paint in 3 coats, all dewatering including emptying
the pipline and refilling the same after done with (water to be supplied
by department free of cost within 5 km. lead at fixed point and all other
arrangements to be done by agency), including carrying out C value
performance test of pipeline, complete job as per the directions of the
Engineer-in-charge.

9 mm thick for pipes upto 700 mm dia.

Sq.m

12 mm thick for pipes above 700 mm dia.

Sq.m

23

Providing and applying of elastomeric (450% elongation),


thermoplastic, fire retardant, coating skin tensile strength 18 to
2
21 kg/cm , antifungal antibacterial anticorrosive, graft copolymer Coating on smooth plastered surface. 100 Micron dyu
film thickness of Self bonding with plastered surface and 100
Micron of top coat. For sewage treatment plant
(
R.C.C.Tank inside coating) and water treatment plant.

Sq.m

326
377
1057

24

Providing and applying external and internal coating for steel


structures in sewage treatement plant/water treatement plant
with elastomeric (450% elongation), thermoplastic, fire
retardant, coating skin tensile strength 18 to 21 kg/cm2,
antifungal antibacterial, anticorrosive, graft co-polymer. 50
Micron DFT. of self bonding grade with steel, 50 Micron DFT.
of inner coat and 50 Micron DFT of top coat.

Sq.m

618

25

Providing and applying of elastomeric (450% elongation),


thermoplastic, fire retardant, coating skin tencile strength 18 to
21 kg/cm2, antifungal, antibacterial anticorrosive, graft copolymer Coating on external pipe lines in un laid/laid condition
after proper cleaning. 50 Micron DFT of self bonding grade
with metal surface, 50 Micron DFT inner coat and 50 Micron
DFT of top coat.
Water and sewage pipe lines (external) in unlaid condition.
Water and sewage pipe lines (external) in laid condition.

Sq.m
Sq.m

647
663

1
2

Sr No

Item Description

26

Providing and applying of elastomeric (450% elongation),


thermoplastic, fire retardant, coating skin tensile strength 18 to
21 kg/cm2, antifungal, antibacterial anticorrosive, graft copolymer Coating on internal surface of pipe lines. 100 Micron
DFT of site bonding grade with steel surface and 100 Micron
DFT of top coat.
Pipe line in unlaid condition
Pipe line in laid condition
Providing and applying of elastomeric (450% elongation),
thermoplastic, fire retardant, coating skin tensile strength 18 to
21 kg/cm2, antifungal, antibacterial anticorrosive, graft copolymer Coating on cleaned steel reinforcement bars. 80 to
100 Micron DFT with self bonding trade of bar coating.

1
2

27

1
2
3
4
5
6
7
8
9

6 mm dia
8 mm dia
10 mm dia
12 mm dia
16 mm dia
20 mm dia
25 mm dia
32 mm dia
40 mm dia

Unit

Rate
( in Rs.)
2012-2013

Sq.m
Sq.m

814
869

MT
MT
MT
MT
MT
MT
MT
MT
MT

29598
22648
17947
14933
11182
9100
7187
5759
4373

Sr No

Item Description

28

Providing and applying HDPEcoating for MS pipe internally as


well as externally including cost of HDPE powder moulding
pipes grade , labour , scrapping the pipe surface with wire
brushes, degrading , cleaning by compressed air and surface
grinding and finishing including cost of loading , unloading and
handelling pipes at factory etc. complete as directed by
Engineer - in -Charge ( Factory at Virar Mumbai.).

Unit

Rate
( in Rs.)
2012-2013

H.D.P.E. Total coating Thickness in micron


1
2
3
4

2000
3000
4000
5000

sq.m
sq.m
sq.m
sq.m

1508
1893
2176
2501

You might also like