Problem: CBRxxxx_xxx_S01 have high RTWP due Loose connection of jumper.

Analysis:
1) Check the RTWP.
2) Check the primary and secondary RTWP gap.

Solution: When we checked the primary and Secondary RTWP in LMT we found it have high difference As we
checked the Neb. site RTWP is normal then we suspect to have loose connection. When TE team has tighten the
cable and connector RTWP become normal and difference also very less.