You are on page 1of 18

1000

porcentaje caida tension


Voltaje nominal
factor potencia
I nominal
Resistencia (1000)
Inducancia (1000)
reactancia
T

k1
k2
k3
In x Ft x Fh

3%
380
11.4
1.7320508076
0.85 0.554811033
75
0.089
0.0000890
0.107
0.0001070
33.62
0.0336
0.910
0.981
1.000
66.95325

0.89271

131.57894737
0.03
89.8483027
F1
0.00000001

0.00007565

7.921E-009

0.00031357
0.01770782 0.001129971
X
0.01770798
0.01778347
0.03361516
|z|
0.03067
0.03080
0.05822
|z|xraiz(3)
2.3003345267 2.3101407585 4.3667372745 2.0535316353 2.0622857565 Ix|z|xraiz(3)
0.4347193803 0.432874056 0.2290039307 0.486965958 0.484898854
4.9558009358 4.9347642381 2.6106448094 5.5514119208 5.5278469358
666

0.10666667

1000
porcentaje caida tension
Voltaje nominal
factor potencia
I nominal
Resistencia (1000)
Inducancia (1000)
reactancia
T

k1
k2
k3
In x Ft x Fh

3%
380
11.4
1.7320508076
0.85 0.554811033
200
0.089
0.0000890
0.107
0.0000892
33.62
0.0280
0.910
0.981
1.000
178.542

0.89271

131.57894737
0.03
89.8179634
F1
0.0000000

0.00007565

0.000000

0.0002178
0.00004697
0.000000
X
0.01475671
0.00012262
0.000126
|z|
0.02556
0.00021
0.00022
|z|xraiz(3)
5.1118750286 0.0424773185 0.0436417613 4.5634219568 0.037919927 Ix|z|xraiz(3)
0.1956229357 23.541975709 22.913832283 0.2191338012 26.371358794
2.2301014669 268.37852308 261.21768803 2.498125334 300.63349025
666

V= In x (Rcos()+Xsen())
V= In x (rcos()+xsen()) x L
Tensin de operacin

Vf
In
fp
[]
[rad]
Resistencia por [/km]
Reactancia por [/km] @ 60[Hz]
Reactancia por [/km] @ 50[Hz]
[]
[rad]

|Z|=|r+jx|
(rcos()+xsen())
In x (rcos()+xsen())
|In| x|Z|
Ft
Fh
K2

11.40
374.89
380
50
0.85
31.79
0.55
0.0720
0.0675
0.0563
37.9987
0.6632

0.0001
0.0001
0.0045
0.0046
0.91
0.98
0.65

Calibre
3.00%
1.35%
19
100%

100
119
119

r
x @ 60[Hz]

I'n

conductores por fase


300
2
500
0.089
0.128
430
391.3
782.60

In x Fh x Ft x K2

254.345

0.0000720 [/m]
0.0000563 [/m]

0.0908315262

L1 [m]
L2 [m]
Longitud real
V= In x (Rcos()+Xsen())

1,449
1,441
650
5.11
2.952024601

ductores por fase


400
0.108
0.131
380
345.8
691.6

350
0.125
0.131
350
318.5
637

300
0.144
0.135
320
291.2
582.4

224.77

207.025

189.28

V= In x (Rcos()+Xsen())
V= In x (rcos()+xsen()) x L
Vf
In
fp
[]
[rad]
Resistencia por [/km]
Reactancia por [/km] @ 60[Hz]
Reactancia por [/km] @ 50[Hz]
[]
[rad]

|Z|=|r+jx|
(rcos()+xsen())
In x (rcos()+xsen())
|In| x|Z|
Ft
Fh
K2

11.40
367.83
380
119
0.85
31.79
0.55
0.0720
0.0675
0.0563
37.9987
0.6632

3.00%
3.20%
19
100%

0.0000720
0.0000563

0.00009137
0.00009083 0.0908315262
0.0108
0.0109
0.91
0.98
0.65

Calibre
100
119
119

r
x @ 60[Hz]

I'n

conductores por fase


300
2
500
400
0.089
0.108
0.128
0.131
430
380
391.3
345.8
782.60
691.6

In x Fh x Ft x K2

254.345

[/m]
[/m]

L1 [m]
L2 [m]
Longitud real
V= In x (Rcos()+Xsen())

609
605
650
12.17
7.02581855

224.77

350
0.125
0.131
350
318.5
637

300
0.144
0.135
320
291.2
582.4

207.025

189.28

r
-

V1
In

0.55

0.0

0.0

0.1

V1-V2

7.0

0.8

7.1

212.4 1.5

0.8
0.9

212.4
1.8

21,528.9

13,235.4

25,271.9

1.5
1.6

0.4
0.5

1.6
1.6

38.6
2.9
2.9
7,812.5
5,422.8

134.1
8.0
212.0
28,421.9

75.82
0.5
0

Zl2
Zt2
In2
V1-V2
V2

85.27

62.7

219.4
119.0

Zlinea

V2
Zl1
S

i
219.4
101.2 -

128.4 7.4
212.0 27,327.1
5,798.2 -

0.555

0.0
-31.8

0.663

38.0

0.108

6.2

0.004
0.551

-0.2

0.551

31.6

0.278
0.292

16.0
16.7

0.292
0.371
0.014
0.278

16.0

7.02

Calibre
3x25+50
3x35+50
3x50+50
3x70+50

Cada de tensin para alimentador preensamblado tablero 400-T


Corriente admisiblea 40 Caida de tensin V/A/km
ambiente y 90 conductor
a 60
a 90
76
2.00
2.20
96
1.50
1.65
117
1.15
1.25
152
0.80
0.90

* Segn cuadro de cargas plano C620-DW-E-002_R2. Hay que confirmar consumo real de UPS y bar
** Cada Tensin= (L x Ic x V/A/km)/380

ador preensamblado tablero 400-TDFI-002


Consumo cargas Cada Tensin a L=650 [m] en [%]**
400-TDFI-002 Ic
a 60
a 90
[A]*
5.87%
11.98%
8.17%
8.99%
31.84
6.26%
6.81%
4.36%
4.90%

e confirmar consumo real de UPS y barra de 120[v]

3640
4041.2209442197
3088.8888888889
4.6930811355

0.9007178895

Calibre
3x25+50
3x35+50
3x50+50
3x70+50

Corriente admisible a 40
ambiente y 90 conductor
76
96
117
152

Cada de tensin para alimentador pre


Caida de tensin V/A/km
a 60
a 90
2.00
2.20
1.50
1.65
1.15
1.25
0.80
0.90

* Segn cuadro de cargas plano C620-DW-E-101_R2. Hay que confirmar consumo real de UPS y bar
** Cada Tensin= (L x Ic x V/A/km)/400

CUADRO DE C
CCM

Circuito
Barra
1
2

fgonzale

a de tensin para alimentador preensamblado CCM 400-MC-201


Cada Tensin a L= 400[m] **
Consumo cargas 400-TDFI-002
Ic [A]*
a 60
a 90
15.96%
336
30.03%
11.97%
352
22.52%
84.0
9.18%
363
17.06%
6.38%
374
12.28%

e confirmar consumo real de UPS y barra de 120[v]

CUADRO DE CARGAS 400-MC-201


Potencia
Tipo Equipos
[kW]
Bomba Impulsion PLS
37.3
Tablero de fuerza y alumbrado
8.0
45.3

Corriente por fase [A] @ 380 [V]


R
S
70.8
70.8
13.2
13.2
84.0
84.0

400[m] **
a 90
280
310
332
351

fase [A] @ 380 [V]


T
70.8
70.8

Tension
longitud
servicio [V]
[m]
380
380
400
380
380