LINE DESIGNATION
X - GR - ###YYY - ZZZ
X - NOMINAL LINE SIZE
GR - COMMODITY
### - PLANT UNIT NUMBER
(V) - VACUUM SERVICE
LINE BREAK
F
HOSE CONNECTION
(HC)
4=WAY VALVE
(VA4WY)
D
FUTURE LINE
245
CW RETURN
UNDERGROUND LINE
TO HEADER
TRACED LINE
AREA XXX
B/L
BATTERY LIMIT
(XXX=MATCHING AREA
CODE NUMBER)
CONTROL VALVE
AND DIAPHRAGM ACTUATOR
(CV)
CONTINUATION ARROW
TO ANOTHER DRAWING
(ARROW 1)
CONTROL VALVE
AND DIAPHRAGM ACTUATOR
[WITH HANDLEWHEEL]
(CV1)
CONTINUATION ARROW
TO/FROM ANOTHER DRAWING
GATE VALVE
(VGA)
LINES CONNECTED
(ARROWS AS REQUIRED)
GLOBE VALVE
(VGL 1)
SINGLE ACTION
CYLINDER ACTUATOR
(AIR (PISTON) OPERATED VALVE)
(AIRV)
SOLENOID VALVE
MANUAL RESET
(SOLEMANR)
SPADE BLIND
(BLD)
SPACER
(SPACER)
LINES CROSSING
NOT CONNECTED
Y TYPE GLOBE
(VGLY)
PNEUMATIC SIGNAL
[INSTAIR]
CONVAL VALVE
W/HILTAP COUPLING
ELECTRICAL SIGNAL
[ELECTRICAL]
NEEDLE VALVE
(VND)
CONCENTRIC REDUCER
(RED)
PROCESS MEASUREMENT
OR MECHANICAL LINKAGE
[PROCESS]
ECCENTRIC REDUCER
(ECCFOT)
(ECCFOB)
INSTRUMENT CAPILLARY
TUBING (CAPILL)
PLUG VALVE
(VPLG)
SILENCER
(SIL)
FLAME ARRESTOR
(FLAME)
SOFTWARE LINK
(SOFTWARE)
CHECK VALVE
(VCHK)
XX
INTERMITTENT PURGE
REFER TO COMMODITY
DESIGNATIONS FOR XX
(PURGEINT)
DETONATION ARRESTOR
FOUNDATION FIELDBUS
SIGNAL (FF)
XX
CONTINUOUS PURGE
REFER TO COMMODITY
DESIGNATIONS FOR XX
(PURGECON)
HYDRAULIC
(HYDRA)
TRAP STATION
(TRAP)
XXX
001
TIE POINT SYMBOL (TP).
SEE NOTES
NOTE NUMBER
SP
001
ELECTROMAGNECTIC,
SONIC OR NUCLEAR
SIGNAL (ELECMAG)
BALL VALVE
(VBA)
ELECTROMAGNECTIC,
SONIC SIGNAL (NOT GUIDED)
BALL VALVE
HIGH PRESSURE
SIDE SHADED
DIAPHRAGM SEAL
(SEAL)
SPECIALTY TAG
(SPTAG)
HUB JOINT
SEWER DRAIN
(SEWEROP)
REFER TO SEWER
DESIGNATIONS FOR XX
XX
P&ID NO.
JACKETED PIPE
((JACKET)
HUB JOINT
WITH BLIND
XX
SS
001
P&ID NO.
FLOW ARROW
(ARRFLW)
S-4
SAMPLE POINT
- MP - 001
PP
50
ET 20
50
INSTRUMENT ARROW
(ARRINT)
RELIEF VALVE
(RV)
GRADE
(GRADE)
SEAL LEG
(SLEG)
UT
UTILITY STATION
(USTN)
PRESSURE / VACUUM
(RVPRES)
TEMPORARY STRAINER
(TS)
XX
EXPANSION JOINT
(EXJ)
DIAPHRAGM VALVE
(VDIA)
T.S.
DAB(U) CAB
RS
P & ID No.
GR
Y-TYPE PERMANENT
STRAINERS
(YTP)
COMMODITY DESIGNATIONS
CONTROL VALVE
AND MANUAL ACTUATOR
(HV)
TO / FROM HEADER
T-TYPE PERMANENT
STRAINERS
(TTP)
LP STEAM
SPEC BREAK
(SPECBRK)
REMOVABLE SPOOL
AA
AC
AI
AP
AR
AU
BA
BD
BO
CA
CL
CT
CWS
CWR
DM
DO
DT
ET
FL
GC
GF
GH
GHH
GHL
GI
GN
GO
GP
GR
GS
GW
GX
HS
HT
IN
KA
KC
KP
KS
KW
OF
OH
OL
OS
OP
OPH
OPL
OM
P
PA
PC
PT
RA
RE
RP
SCH
SC
SCL
SE
SH
SI
SL
SM
SS
SN
SO
ST
SV
TT
VA
VT
WA
WB
WC
WD
WF
WH
WI
WK
WL
WM
WP
WR
WS
WT
WU
WW
WX
WF
WZ
XT
UTILITY
CONTROL VALVES
FO - FAIL OPEN
FC - FAIL CLOSED
FL
- FAIL LOCK LAST POSITION
FL(O) - FAIL LOCK (ULTIMATE OPEN)
FL(C) - FAIL LOCK (ULTIMATE CLOSE)
FX(C) - FAIL INTERMEDIATE (ULTIMATE CLOSE)
FX(O) - FAIL INTERMEDIATE (ULTIMATE OPEN)
TSO - TIGHT SHUTOFF
C
TIE-IN POINTS SHALL BE DESIGNATED AS FOLLOWS
PLT. UNIT NO.
###
--SEQUENCE NO.
ISSUED
DATE
DESCRIPTION
OTHER_DESIGNATIONS
AE
NNF
HV
FP
ADDITIONS / MODIFICATIONS
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
SHELL CANADA
- ANALYZER
- NORMALLY NO FLOW
- HAND CONTROL VALVE
- FULL PORT
SEWER_DESIGNATIONS
FOR XX, USE THESE SYMBOLS
FLEXIBLE HOSE
(FH)
BUTTERFLY VALVE
(VBFY)
ANGLE VALVE
(VANG)
END FLANGED
(ENDFLG)
FIRE HYDRANT
UP 1:500 LEVEL
CHANGE OF SLOPE
(SLOPE)
FIRE HYDRANT
WITH MONITOR
DISSIMILAR MATERIAL
WELDING
FREE DRAINING
FREE DRAINING
DA
DB
DC
DF
DK
DM
DO
DP
DR
DS
EF
OS
- ACID SEWER
- BENZENE DRAIN
- CAUSTIC SEWER
- DRAIN FLUSH (CLOSED HYDROCARBON DRAIN)
- CHEMICAL SEWER
- AMINE SEWER
- OILY WATER SEWER (OPEN)
- PROCESS DRAIN
- STORM SEWER
- SANITARY SEWER
- POND EFFLUENT
- OILY SEWER (CLOSED - ABOVE GROUND)
200.0000.000.041.007
REV.
200.007
FUTURE
2
LEGEND FOR
FUNCTIONAL LOGIC DIAGRAMS
WEIGHT
MISCELLANEOUS
POSITION
P PD Q
PA PDA QA
PAL PDAL QAL
PC PDC QC
PCV PDCV PE
QE
PG PDG PI PDI QI
PIC PDIC QIC
PIK PDIK QIK
PIS PDIS QIS
PIT PDIT QIT
PR PDR QR
PRC PDRC QRC
PRS PDRS QRS
PRT PDRT QRT
PS PDS QS
PSL PDSL QSL
PT PDT QT
PV PDV QV
PX PDX QX
PY PDY QY
PZ PDZ QZ
VISCOSITY
M
MA
MAL
MC
ME
MI
MIC
MIK
MIS
MIT
MR
MRC
MRS
MRT
MS
MSL
MT
MV
MX
MY
MZ
MULTI VARIABLE
L
LA
LAL
LC
LCV
LE
LG
LI
LIC
LIK
LIS
LIT
LR
LRC
LRS
LRT
LS
LSL
LT
LV
LX
LY
LZ
TEMPERATURE
DIFFERENCE
K
KA
KAL
KC
KE
KG
KI
KIC
KIK
KIS
KIT
KR
KRC
KRS
KRT
KS
KSL
KT
KV
KX
KY
KZ
TEMPERATURE
MOISTURE OR
HUMIDITY
J
JA
JAL
JC
JI
JIC
JIK
JIS
JIT
JR
JRC
JRS
JRT
JS
JSL
JT
JV
JX
JIY
JZ
SPEED
LEVEL
I
IA
IAL
IC
II
IIC
IIK
IIS
IIT
IR
IRC
IRS
IRT
IS
ISL
IT
IV
IX
IY
IZ
PRESSURE
DIFFERENCE
QUANTITY
OR EVENT
TIME OR TIME
SCHEDULE
H
HA
HAL
HC
HI
HIC
HIK
HIS
HR
HRC
HRS
HS
HSL
HV
HX
HY
HZ
PRESSURE
POWER
S
SA
SAL
SC
SE
SI
SIC
SIK
SIS
SIT
SR
SRC
SRS
SRT
SS
SSL
ST
SV
SX
SY
SZ
T
TA
TAL
TC
TCV
TE
TG
TI
TIC
TIK
TIS
TIT
TR
TRC
TRS
TRT
TS
TSL
TT
TV
TX
TY
TZ
TD
TDA
TDAL
TDC
TDCV
TDIC
TDIK
TDIS
TDIT
TDR
TDRC
TDRS
TDRT
TDS
TDSL
TDT
TDV
TDX
TDY
TDZ
U
UA
UAL
UC
UCV
UI
UIC
UIK
UIS
UIT
UR
URC
URS
URT
US
USL
UT
UV
UX
UY
UZ
V
VA
VAL
VC
VE
VG
VI
VIC
VIK
VIS
VIT
VR
VRC
VRS
VRT
VS
VSL
VT
VV
VX
VY
VZ
W
WA
WAL
WC
WCV
WI
WIC
WIK
WIS
WIT
WR
WRC
WRS
WRT
WS
WSL
WT
WV
WX
WY
WZ
X
XA
XAL
XC
XCV
XE
XG
XI
XIC
XIK
XIS
XIT
XR
XRC
XRS
XRT
XS
XSL
XT
XV
XX
XY
XZ
Z
ZA
ZAL
ZC
ZE
ZI
ZIC
ZIK
ZIS
ZIT
ZR
ZRC
ZRS
ZRT
ZS
ZSL
ZT
ZV
ZX
ZY
ZZ
THE COMBINATION OF LETTERS SHOWN INCLUDE THOSE MOST FREQUENTLY ENCOUNTERED. OTHER COMBINATIONS MAY BE DERIVED FROM TABLE 1 ISA-S-5.1
STANDARD. IF AN INSTRUMENT HAS ADDITIONAL FUNCTIONS, IT SHOULD BE SHOWN BY TWO GROUPS OF LETTERS RATHER THAN EXCEEDING THREE LETTERS
(E.G. FQI AND FRC NOT FQIRC).
XIS USED TO IDENTIFY COMPUTING TYPE RELAYS, FUNCTION CAN BE
ANALYZERS MAY BE FURTHER IDENTIFIED BY DESCRIPTIVE LETTERS OR
ASHOWN OUTSIDE BALLOON.
WORDS WRITTEN OUTSIDE THE TAGGING BALLOON.
YIS USED TO SHOW ON/OFF TYPE NON ADJUSTABLE RELAYS IN A LOOP.
CIS USED WITH ZSC TO GIVE CLOSED POSITION.
- I.E.- SOLENOIDS, PNEUMATIC 3-WAY VALVES ETC.
ARE MODIFYING LETTERS FOR DIFFERENCE (D), FRACTION OR RATIO (F),
THE SUFFIX LETTER "E" IS TO BE USED TO IDENTIFY COMPONENTS OF
EAND QUALITY OR TOTAL (Q). THEY MAY BE USED WITH OTHER FIRST
D, F, Q,A SAFETY SYSTEM - I.E.- SHUTDOWN, DEPRESSURING, LOCK UP, ETC.,
LETTERS THAN THOSE SHOWN IN THE TABLE , E.G. KQ-TOTAL TIME,
(PALE - ALARM ON LOW PRESSURE SHUTDOWN).
SD-SPEED DIFFERENCE, DF DENSITY RATIO.
VWILL BE USED OUTSIDE BALLOON TO IDENTIFY VENDOR SUPPLIED INSTRUMENTS.
JIS USED FOR SCANNING - I.E.- FOR TEMPERATURE TJI OR TJR.
TWO STAGE VABIABLE ALARMS SHALL BE IDENTIFIED BY H AND HH,
H/L IS USED FOR PILOT LGHT. THE LETTER "L" MAY BE USED ALONE
OR L AND LL, - I.E.- H- HIGH LEVEL ALARM
LOR IF PART OF A LOOP, IT CAN TAKE THE LOOP LETTERS AS A PREFIX.
- HH- VERY HIGH LEVEL ALARM
E.G.F. , ETC.
NOTE: SAFETY SYSTEM WILL BE GENERALLY BE HE NOT HHE.
NIS USER'S CHOICE - EITHER AS A MEASUREMENT OR OUTPUT FUNCTION.
WILL BE USED OUTSIDE BALLOON TO IDENTIFY INSTRUMENTS AT LOCAL PANELS.
LP IS USED WITH F TO GIVE FO, FLOW ORIFICE RESTRICTION.
IF MORE THAN ONE PANEL, THEN IDENTIFY THEM NUMERICALLY AND
OIS USED WITH ZSO TO GIVE OPEN POSITION.
REFERENCE IN GENERAL NOTES.
R-
U-
W-
2.
XHS
O/C
LP
XHIS
O/C
LC-
CB-
PILOT LIGHT
R = RED
G = GREEN
R
3.
RELAY
KR
RELAY COIL
IF MEASUREMENT POINT HAS A LOGIC INTERLOCK; THE INDICATED VALUE WILL BE AVAILABLE
IN THE DCS. THE LL OR HH SIGNIFIES THE TRIP ACTION UNDER ENGINEERING CONTROL,
WHICH THE OPERATOR CANNOT ADJUST.
5.
6.
8.
9.
CB
147 B
UE
197
FIC
113
113
BACK OF PANEL
OR RACK MOUNTED
INSTRUMENT
FRONT PANEL
INSTRUMENT
PSHE
005
*YE
197
FR
TXE
113
147
HIGH PRESSURE
SHUTDOWN
SWITCH
SOLENOID VALVE
ON EMERGENCY
SYSTEMS
INSTRUMENT
ON LOCAL
PANEL
RELAY
FUNCTION
=SUMMING
MULTIFUNCTION
LOGIC FOR
EMERGENCY
SYSTEMS
LP
002
SIS INTERLOCK
NO.002
I
001
FT
004
AND
SIGNAL INVERTER
DCS INTERLOCK
NO.001
*E
HEAT TRACED
TRANSMITTER
SNAP ACTING
RELAY ON TEMP.
TRIP SYSTEM
GENERAL_INSTRUMENTS_SYSTEMS
FUNCTION IN DCS SYSTEM
DISPLAY TO OPERATE
INSTRUMENT ABBREVIATION
DCS STATUS LIGHT
A/S - INSTRUMENT AIR SUPPLY
FE - FLOW ELEMENT
INSTRUMENT IDENTIFICATION_NUMBERS
THE IDENTIFICATION NUMBER FOR LOOPS WILL HAVE SIX DIGITS, THE FIRST THREE BEING UPGRADER COMPLEX UNIT NUMBER.
THE FOLLOWING THREE DIGITS WILL PROVIDE A SINGLE SEQUENCE OF LOOP NUMBERS FOR EACH PROCESS VARIABLE
IDENTIFICATION OF EACH LOOP.
THE LOOP NUMBERING SEQUENCE WILL BEGIN WITH THE NUMBER 001 FOR EACH PROCESS VARIABLE IDENTIFICATION FOR
EACH UNIT, INCLUSIVE OF THE FOLLOWING LOCAL INSTRUMENTS.
PG - PRESSURE GAUGES
IDENTIFICATION LETTERS:
TG - DIAL THERMOMETER
TXE
147
NOTES
- PURGEMETERS
NOTES
FO - FLOW ORIFICE
START
HAND
MANUAL
STOP
OFF
TRIP
2. SOME TYPICAL FUNCTIONS ARE:
RUN
AUTO
RESET
READY
JOG
ARMED
FUNCTIONAL ABBREVIATIONS MAYBE USED:
-S/S - START/STOP
-HOA - HAND-OFF-AUTO
3. NUMBERING SHALL FOLLOW THE SAME PROCEDURE AS INSTRUMENTS.
4. FOR MOTOR CONTROL SWITCHES AND LIGHTS, ONLY PANEL MOUNTED ITEMS ARE SHOWN
ON P&ID'S EXCEPT WHERE LOCAL DEVICES ARE OTHER THAN START/STOP.
ALL LOCAL DEVICES ARE THE RESPONSIBILITY OF THE ELECTRICAL DEPT.
R/S
HIS
110
DESCRIPTION
UNIT NO.
HOA
HS
110
CKD
PRS
HIS
111
TO PUMP
P-100A MOTOR
SIS INTERLOCK
APE
PEM CLIENT
APP
SHELL CANADA
QUEST CCS PROJECT
HOA
HS
111
INTERLOCK NUMBERS ARE SIX DIGITS AND ARE ASSIGNED BY THE INSTRUMENT DEPARTMENT. THE FIRST THREE DIGITS DESIGNATE
THE UNIT AND THE LATTER THREE ARE SEQUENTIAL, COMMENCING AT 001 IN EACH UNIT. THE FIRST THREE DIGITS ARE OMITTED ON
THE P&ID.
R
EXAMPLE
DCS OR PLC INTERLOCK
MC
PDP
WITH THE EXCEPTION OF HAND SWITCHES, FOR INSTRUMENTS THAT ARE LOCATED ON IDENTICAL PARALLEL EQUIPMENT,
THE IDENTICAL INSTRUMENTS ON EACH PIECE OF EQUIPMENT SHALL BE NUMBERED XXXA, XXXB, XXXC ETC. EXAMPLE: PARALLEL
INSTRUMENTS SHALL BE NUMBERED 017A, 017B & 017C.
R/S
CS
LOOP NO.
THE FIRST THREE DIGITS (UNIT NUMBER) WILL BE OMITTED FROM THE BALLOONS FOR IMPROVED READABILITY OF LOOP
IDENTIFICATION NUMBERS. A GENERAL NOTE ON THE P&ID WILL REFERENCE THIS AND IDENTIFY THE OMITTED PLANT NUMBER.
THE INSTRUMENT LOOP NUMBERS WILL THEN BE THREE DIGITS, I.E. 017.
BY
FC-245 017
SEL
HS
112
ISSUED
DATE
EXAMPLE
SNAP
AUXILIARY LOCATION
NORMALLY INACCESSIBLE
TO AN OPERATOR
OR
RESISTOR
MOTOR CONTROL
FX
DCS ALARM
INSTRUMENTS SYMBOLS
INSTRUMENT
FUNCTION
PI
113
LOOP NO.
FIELD OR LOCAL
INSTRUMENT
AND
7.
CONTACTS
LIMIT SWITCH
SINGLE - POLE
SINGLE - THROW [SPST]
E
LL
4.
OR
LTE
Y = AMBER
B = BLUE
KR
N-
S-
FOR ELABORATE CONTROL SYSTEMS A SEPARATE DRAWING (EITHER VENDOR OR CONTRACTOR) MAY BE REQUIRED.
IN SUCH A CASE, A BLOCK WILL BE DRAWN ON THE P&ID WITH A DRAWING NUMBER IDENTIFICATION AND SHOWING
ALL THE INPUT AND OUTPUT SIGNALS.
TO PUMP
P-100B MOTOR
START/STOP AND H-O-A HAND SWITCHES FOR PUMP "A" WILL HAVE A
SEQUENTIAL NUMBER. A DIFFERENT SEQUENTIAL NUMBER IS USED FOR PUMP "B".
THE DCS SOFT DEVICE BLOCK TAG WILL NOT HAVE A SUFFIX (I.E. HS-110) THE
LOCAL HAND SWITCHES FOR H-O-A AND LOCAL START/STOP WILL HAVE SUFFIX
STARTING WITH A (I.E. HS-110A). COMMON HAND SWITCH FOR BOTH PUMPS
(I.E. SELECTOR SWITCH) WILL HAVE ITS OWN SEQUENTIAL NUMBER.
001
002
200.0000.000.041.008
REV.
BV
BX
BY
BZ
CURRENT
BS
F FF FQ G
FA FFA FQA GA
FAL FFAL FQAL GAL
FC FFC FQC GC
FCV FE
GE
FG
FI FFI FQI GI
FIC FFIC FQIC GIC
FIK FFIK FQIK GIK
FIS FFIS FQIS GIS
FIT FFIT FQIT GIT
FR FFR FQR GR
FRC FFRCFQRC GRC
FRS FFRS FQRS GRS
FRT FFRT FQRT GRT
FS FFS FQS GS
FSL FFSL FQSL GSL
FT FFT FQT GT
FV FFV FQV GV
FX FFX FQX GX
FY FFY FQY GY
FZ FFZ FQZ GZ
HAND
BE
BG
GAUGING
E
EA
EAL
EC
EI
EIC
EIK
EIS
EIT
ER
ERC
ERS
ERT
ES
ESL
ET
EV
EX
EY
EZ
FLOW TOTAL
D
DA
DAL
DC
DE
DI
DIC
DIK
DIS
DIT
DR
DRC
DRS
DRT
DS
DSL
DT
DV
DX
DY
DZ
FLOW RATIO
C
CA
CAL
CC
CE
CI
CIC
CIK
CIS
CIT
CR
CRC
CRS
CRT
CS
CSL
CT
CV
CX
CY
CZ
FLOW
VOLTAGE (EMF)
B
BA
-C
1. AS A GENERAL GUIDE, THE EXTENT OF INSTUMENTATION SHOWN ON THE P&ID SHOULD BE SUFFICIENT TO PERMIT
THE OBSERVER TO IDENTIFY THE MAIN COMPONENTS AND THE FINAL READOUT CONTROL AND/OR ALARM ACTION
AND TO UNDERSTAND THE FULL FUNCTION OF THE INSTRUMENT SYSTEM. IDENTIFICATION OF ALL COMPONENTS
AND THE FULL SCHEMATIC RELATIONSHIP ARE SHOWN ON THE INSTRUMENT HARD WIRED LOOP DWGS.
LEGEND FOR
FUNCTIONAL LOGIC DIAGRAMS
200.008
DENSITY
A
AA
AAL
AC
AE
AI
AIC
AIK
AIS
AIT
AR
ARC
ARS
ART
AS
ASL
AT
AV
AX
AY
AZ
CONDUCTIVITY
INSTRUMENT FUNCTION
ALARM
ALARM LOW (L), MEDIUM (M), HI (H)
CONTROL
CONTROL VALVE (SELF OPERATING)
ELEMENT
GAUGE GLASS (TUBE)
INDICATOR
INDICATING CONTROLLER
INDICATING CONTROL STATION
INDICATING SWITCH
INDICATING TRANSMITTER
RECORDER
RECORDING CONTROLLER
RECORDING SWITCH
RECORDING TRANSMITTER
SWITCH
SWITCH LOW (L), MEDIUM (M), HI (H)
TRANSMITTER
CONTROL VALVE OR DAMPER
MISCELLANEOUS
RELAY TRANSDUCER ETC
DRIVE OR ACTUATOR
BURNER FLARE
ANALYZER
MEASURED VARIABLES
FLOW
LEVEL
PRESSURE
TEMPERATURE
CONT.
FE
169
ORIFICE PLATE WITH
FLANGE TAPS
SOLENOID
OPERATED
DIAPHRAGM VALVE
WITH SMART
POSITIONER
FAILS CLOSED
FE
169
GAUGE GLASS
EXTERNALLY
CONNECTED
LG
018
ORIFICE PLATE
COMPLETE WITH LOCAL
FLOW INDICATOR
TE
577
PRESSURE GAUGE
DIRECT CONNECTED
TE
578
TE
579
TANK
PSE
046
TANK
FC
FE
172
FO
DIAPHRAGM GLOBE
WITH SMART POSITIONER
WITHOUT HANDWHEEL
FAILS OPEN
RUPTURE
DISC
ORIFICE PLATE
WITH VENA
CONTRACTA
RADIUS OR
PIPE TAPS
LG
020
MAG
FE
173
FL
WATER
SLIDE VALVE
HP
STEAM
TANK
FV
001
PP
045
LT
020
WINTERIZED
LEVEL TRANSMITTER
EXTERNAL FLOAT
TANK
TEMPERATURE
FC
006
VENTURI TUBE
OR FLOW NOZZLE
MOTOR OPERATED
(MOV) VALVE
WITH HANDWHEEL
LEVEL TRANSMITTER
DP TYPE
TANK
FT
179
PCV
420
LT
324
LEVEL TRANSMITTER
DP TYPE WITH
BUBBLER SYSTEM &
DIP TUBE
FLUME
PCV
421
LY
324
WITH EXTERNAL
PRESSURE TAP
FI
087
ROTAMETER OR
PURGEMETER
WITH NEEDLE
VALVE ON INLET
TI
067
087
FT
184
TSE
536
TANK
LEVEL
TANK
LCV
314
LEVEL REGULATOR
WITH MECHANICAL
LINKAGE
FT
001
TG
069
LEVEL INDICATOR
FLOAT WITH WIRE
AND PULLEY
LI
325
LS
327
FLOW SIGHT
GLASS
STRAIGHTING VANES
(STVANES)
CORIOLIS
(CORIO)
M
CAPACITANCE,
DIELECTRIC OR
CONDUCTIVITY
TYPE SWITCH
TANK
SP
ISSUED
DATE
DESCRIPTION
101
101
TTE
311
TTE
311
P&ID ABBREV.
ACTUAL
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
SHELL CANADA
QUEST CCS PROJECT
FC
011
FX
011
CKD
FV
004
FE
004
FLOW COMP
HH
BY
FC
004
TI
311
WEDGE
(WEDGE)
FT
004
INLINE FLOWMETER
WITH INTEGRAL
TRANSMITTER
POSITIVE DISPLACEMENT
(POSDISPL)
LC
002
LT
002
A
R
LX
329
TANK
TANK
LT
329
RADIOACTIVE OR
SONIC SOURCE
TAHH
311
TI
009
TT
009
PI
010
FE
011
FT
011
PT
010
FV
010
MAGNETIC
TEMPERATURE AND PRESSURE COMPENSATION
ADDITIONS / MODIFICATIONS
REV
FIXED
RESTRICTION
ORIFICE
VORTEX
I
003
TANK
FO
185
FUSIBLE PLUG
OR DISC
FYI
001
FO
TEMPERATURE
(REFER TO PROJECT
DWG. 245.0000.000.041.002)
THERMOMETER
POSITIVE
DISPLACEMENT
METER
FG
FV
001
FQI
182
PVSV
025
AI
TANK
TURBINE OR
PROPELLER
FLOW METER
VAC
FO
FILLED SYSTEM
WITH WELL
FT
180
RV
024
FV
006
FC
001
TE
066
FE
186
SELF-CONTAINED
PRESSURE/VACUUM
SAFETY VALVE
SIZE AND SET
PRESSURES
FT
006
TEMPERATURE ELEMENT
WITH OR WITHOUT WELL
(NOT CONNECTED TO
SECONDARY INSTRUMENT)
ULTRASONIC
FLOW METER
FYE
006
002
LT
323
SELF-ACTUATED REGULATORS
VACUUM RELIEF
SAFETY VALVE
SIZE AND SET
PRESSURE
TW
064
WEDGE
TEMPERATURE
TEST CONNECTION
WITH WELL
FE
178
(REFER TO PROJECT
DWG. 245.0000.000.041.002)
FC
PRESSURE POINT
FE
177
FT
001
EXCESS FLOW
VALVE
FC
001
PRESSURE GAUGE
DIAPHRAGM SEAL
LINE MOUNTED
FSV
099
LP
STEAM
FC
LEVEL TRANSMITTER
INTERNAL FLOAT
SIDE CONNECTION
LT
322
PITOT OR
PITOT VENTURI
OR ANNUBAR
DESUPERHEATER
(DESUPER)
PURGEMETER
OR ROTAMETER
TYPICAL LOOPS
PG
044
FE
176
PCV
999
THERMAL RADIATION
TYPE TEMPERATURE
ELEMENT
REMOTE PRESSURE
GAUGE WITH CAPILLARY
& LINE MOUNTED
DIAPHRAGM SEAL
ORIFICE PLATE
CONNECTED TO
DIFFERENTIAL
PRESSURE
FLOW TRANSMITTER
FI
081
TE
581
PG
043
FT
173
DOUBLE ACTING
CYLINDER
THREE WAY VALVE
FAILS LOCKED
IN LAST POSITION
SINGLE ACTING
CYLINDER
ANGLE VALVE
FAILS CLOSED
FURNACE
LEVEL INDICATOR
MAGNETIC TYPE
TANK
FC
MULTI-ELEMENT
THERMOCOUPLE FOR
DIFFERENT ELEVATIONS
WITH WELL IN TANK
FO
SCALE: NONE
SHELL DWG NO.:
200.0000.000.041.009
REV.
PG
042
200.009
CONTROL VALVE
1. AUTOCAD BLOCK NAMES ARE SHOWN IN ROUND BRACKETS UNDER THE SYMBOL
DESCRIPTION.
D
TXT
NO.
FIELD INSTRUMENT
(INSTR1)
I
I
CURRENT
TO CURRENT
TRANSDUCER
(FDR1)
(ISA S5.1)
THE FUNCTION DESIGNATIONS ASSOCIATED WITH RELAYS SHALL BE USED AS FOLLOWS, INDIVIDUALLY OR IN COMBINATION
NO.
TXT
NO.
LP
BACK OF PANEL OR
RACK MOUNTED INSTRUMENT
(INSTR4)
PROGRAMMABLE LOGIC TYPE
INTERLOCK SYSTEM
(INTLOCK4)
WINTERIZED
NO.
PROPORTIONAL
(FDR5)
A
D
E
I
d
dt
C
f(x)
f(t)
REV
A
M
1.
EXPONENTIAL
(FDR6)
SYMBOL
1-0 or ON - OFF
FUNCTION
AUTOMATICALLY CONNECT, DISCONNECT, OR TRANSFER ONE OR MORE CIRCUITS
PROVIDED THAT IS NOT THE FIRST SUCH DEVICE IN A LOOP
2.
or ADD
3.
or DIFF
SUBTRACT * *
ANALOG TO
DIGITAL
(FDR7)
4.
5.
AVG.
AVERAGE
VOLT TO
CURRENT
TRANSDUCER
6.
DERIVATIVE
(FDR10)
BIAS *
7.
MULTIPLY * *
8.
DIVIDE * *
9.
SQ. RT.
EXTRACT
SQUARE ROOT
(FDR11)
10.
n
1/n
X or X
RAISE TO POWER
11.
f(x)
CHARACTERIZE
NONLINEAR OR
UNSPECIFIED
FUNCTION
(FDR12)
12.
1:1
BOOST
13.
or HIGHEST (MEASURED
VARIABLE)
FUNCTION
OF TIME
(FDR13)
14.
or LOWEST (MEASURED
VARIABLE)
15.
REV.
REVERSE
16.
A/D or D/A
REVERSE
(FOR14)
17.
AUTO
MANUAL
(FDR15)
18.
D or d/dt
DERIVATIVE OR RATE
19.
I/D
INVERSE DERIVATE
RESET FOR
LATCH TYPE
SOLENOID
(FDR16)
20.
AS REQUIRED
UNCLASSIFIED
**
SUMMATION
(FDR17)
MULTIPLY
(FDR18)
1:1
BOOST
(FDR19)
HIGH
SELECTION
(FDR20)
I
P
P
I
CURRENT TO
PNEUMATIC
TRANSDUCER
(FDR21)
PNEUMATIC
TO CURRENT
TRANSDUCER
(FDR22)
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
LOW
SELECTION
(FDR24)
SHELL CANADA
QUEST CCS PROJECT
A
R
200.0000.000.041.010
REV.
TXT
200.010
TXT
NO.
1
NOTES:
DEMISTER
CENTRIFUGAL
COMPRESSOR
WITH GUIDE VANES
(COMPC)
RECIPROCATING PUMP
(PMPRECIP)
STEAM TURBINE
(STMTUR)
DISTRIBUTOR
TROUGH & TRAY
LIQUID SPRAY
(PERFORATED)
VERTICAL
VESSEL
BASIC SYMBOL
(VES)
LIQUID SPRAY
(NOZZLE)
TOTAL DRAW-OFF
VACUUM PUMP
(PMPVAC)
PARTIAL DRAW-OFF
TURBINE WITH
PNEUMATIC
SPEED CONTROL
(STMTURPN)
SPHERE
(SPHERE)
CHIMNEY
HALF PIPE
MANWAY
(MANWAY)
CENTRIFUGAL FAN
OR BLOWER
(CFB)
HIGH SPEED
CENTRIFUGAL
PUMP
(PMPHSC)
RECIPROCATING
COMPRESSOR
(RCOMP)
DIFFUSER
OPEN TANK
(TKOPEN)
CYCLONE
TRAYS
PACKED SECTION
REDISTRIBUTION
(LIQUID/LIQUID)
TRAY WITH
DOWNCOMERS
REDISTRIBUTION
(GAS/LIQUID)
1) SINGLE PASS
BAFFLE WITH
PARTITION
INTERNAL FLGATER
(TKGF)
CETRIFUGAL SIDE
IN/OUT BETWEEN
BEARING PUMP
DOLLAR PLATE
GENERAL
GRID
SIEVE
VALVE
BUBBLE CAP
ROTARY LOBE
BLOWER (RLB)
VERTICAL IN-LINE
CANNED PUMP
(PMPICAN)
VORTEX BREAKER
DOUBLE PIPE
(DPIPE)
INTERNALS WHEN DRAWN TO BE DASHED
EXAMPLES:
METERING PUMP
(PMPMETER)
2) TWO PASSES
INDICATION OF
POINT OF CHANGE
NON-INTEGAL
GEAR BOX
(GEARBOX)
VENDOR
INJECTION PUMP
(PMPINJEC)
KETTLE REBOILER
(REBOIL)
M
ELEVATION FROM
FINISHED SURFACE
AT GRADE
LETTER OF
GROUP
DECSRIPTION
FIRED BOILERS
CG
COMPRESSOR GEARS
CT
COMPRESSOR TURBINE
CM
COMPRESSOR MOTOR
EG
EMERGENCY GENERATOR
EM
EXCHANGER MOTOR
ER
EMERGENCY EQUIPMENT.
GENERATORS
GT
MOTORS
ME
ELECTRIC MOTORS
MF
FAN MOTOR
MM
MIXER MOTORS
Mx
MIXERS, AGITATORS
PUMPS
PG
PUMP GEARS
PM
PUMP MOTORS
PT
PUMP TURBINE
3) CALMING
SECTION
CHANGE IN
RESPONSIBILITY
PACKED COLUMN
BASIC SYMBOL
ST
STEAM TURBINE
TURBINE
Tk
TANKS (ATMOSPHERIC)
HIC
XM
XZ
SEPARATE
CONVECTION COIL
(LOUVERS AS REQUIRED)
LOADING ARM
(LOADARM)
TRUCK LOADING
STATION
(TRKLOAD)
FILTER (FLT)
15
14
VFD
VARIABLE/SINGLE SPEED
MOTOR SHOWN AS REQUIRED
VFD_VARIABLE FREQUENCY
DRIVE
TRAYED COLUMN
BASIC SYMBOL
TRAY NUMBERS
FROM BOTTOM
EJECTOR/INJECTOR
EDUCTOR
BASIC SYMBOL
(EJECTOR)
OIL MIST
DISTRIBUTION
BLOCK WITH 2
RECLASSIFIERS.
ADD RECLASSIFIERS
AS REQUIRED.
(OILMIST)
AIR
ELIMINATOR
(AIREL)
REV
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
SHELL CANADA
QUEST CCS PROJECT
STEAM DRUM
ROTATING DISC
CONTACTOR
MUD DRUM
SHELL & TUBE
VERTICAL
(OVHD_EXCH)
SYNCHRONOUS MOTOR
*DC FOR DC MOTORS
(EMDC)
ADDITIONS / MODIFICATIONS
TIC
MAP
AV
ROTARY SCREW
COMPRESSOR (COMPROTS)
24
ROTARY SCREW
PUMP (PMPROTS)
SWIRL DECK
VORTEX BREAKER
(VORTEX)
MULTISTAGE
PUMP
(PMPMULTI)
1. AUTOCAD BLOCK NAMES ARE SHOWN IN ROUND BRACKETS UNDER THE SYMBOL
DESCRIPTION.
SCALE: NONE
SHELL DWG NO.:
200.0000.000.041.011
REV.
CENTRIFUGAL PUMP
(PMPCENT)
SCHOEPENTOETER
HORIZONTAL
VESSEL
WITH BOOT
(VESBOOT)
IDENTIFICATION OF EQUIPMENT
200.011
3
P
PIPING
INSTR.
PIPING
INSTR.
3/4"
PI
7
3/4"
SAMPLE BOMB
(BY SHELL)
S-3
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
17
S-2
S-3
S-4
S-2
S-3
S-4
S-4A
FL
S-8
S-4A
HYDROCARBONS
45C AND ABOVE
LIQUID HYDROCARBONS
BELOW 45C
S-1
S-8
17
3/4"
S-1
SAMPLE BOTTLE
(BY SHELL)
S-4A
17
FL
S-4
HYDROCARBONS
45C AND ABOVE
17
3/4"
MIN.
3/4"
3/4"
CWS
3/4"
FL
MAIN LINE CLASS
AU
16
13
SAMPLE BOMB
(BY SHELL)
3/4"
16
LIQUID HYDROCARBONS
BELOW 45C
3/4"
7
PI
S-2
PI
CWR
13
PIPING
INSTR.
3/4"
5
3/4"
3/4"
10
PIPING
INSTR.
S-1
PIPING
INSTR.
3/4"
3/4"
TG
PIPING
INSTR.
PI
16
LOWER PRESSURE
SIDE CLASS
MAIN LINE
CLASS
PIPING
INSTR.
1. SEE DRAWING 200.0000.000.041.007, 008, 009, 010, & 011 FOR SYMBOL
IDENTIFICATION AND GENERAL NOTES.
2. ARRANGEMENT S-1 TO BE USED ONLY WHERE THE SAMPLING VALVE CAN BE
WELDED DIRECTLY TO A NORMALLY FLOWING LINE IN AN ACCESSIBLE LOCATION.
TO BE CONFIRMED IN EPC.
3. BRIDGE WELD ALL ROOT VALVES TO THE MAIN LINE EXCEPT IN ARRANGEMENT
LOCATION. TO BE CONFIRMED IN EPC.
4. SEWER CHOICE PER AVAILABILITY.
5. SAMPLE COOLER MODEL NO. LATER.
6. ALL SAMPLE POINTS TO BE LOCATED AT GRADE. WHERE POSSIBLE, INCORPORATE
SAMPLE POINT WITH ANALYZER CONDITIONING TO REDUCE ADDITIONAL COOLING,
ETC. WHERE POSSIBLE, SAMPLES TO BE COOLED BELOW 45C FOR PERSONNEL
PROTECTION.
7. PRESSURE LIMIT FOR SNAP- ON SAMPLE BOMB FITTINGS IS 45 MPa AT 65C. FOR
HIGHER PRESSURES USE DIRECT SCREWED BOMB CONNECTIONS.
8. SAMPLE CONNECTION ON TOP OF HORIZONTAL LINE FOR GAS. SAMPLE
CONNECTION ON SIDE OF HORIZONTAL LINE FOR LIQUID SAMPLE.
9. DELETE SECOND VALVE WHEN ROOT VALVE IS ACCESSIBLE FROM THE SAMPLE
VALVE.
10. THE TYPE OF FITTING (SOCKOLET OR WELDOLET WITH FLANGE) AND THE FIRST
VALVE OR VALVES AT THE MAIN LINE SHALL BE AS PER VENT (OR DRAIN)
REQUIREMENTS FOR THE MAIN LINE PIPING CLASS. SEE SPECIFICATION
245.0311.035.005.
11. THE STEEL CABINET IS TO BE COMPLETE WITH AN INTEGRALLY MOUNTED AIR
EJECTOR. THE FRONT WALL TO BE A CLEAR PLASTIC DOOR. PROVIDE SLOTS IN
THE FLOOR FOR VENTILATION. SEVERAL SAMPLING CONNECTIONS CAN BE BROUGHT INTO THE SAME CABINET. HOWEVER EACH CONNECTION MUST HAVE ITS
OWN SPIGOT TO PREVENT CONTAMINATION.
12. ISOKINETIC SAMPLE PROBE (JONAS) REQUIRED FOR STEAM SAMPLE.
13. SAMPLE LINE PIPING CLASS SHALL CORRESPOND TO THE PIPING CLASS OF THE
MAIN LINE.
14. DO NOT MANIFOLD MORE THAN ONE SAMPLE LINE TO ONE COOLER TO PREVENT
CONTAMINATION.
15. ADD APPROPRIATE WINTERIZATION AND PERSONNEL PROTECTION.
16. SAMPLING VALVES MUST BE CLOSE CONNECTED TO FAST LOOP (SAMPLING
BYPASS).
17.
ANY DEVICE OR INSTRUMENT THAT CREATES A PRESSURE DROP
P
TO ASSURE OF SUFFICIENT FLOW THROUGH THE FAST LOOP.
P&ID SYMBOL MAY VARY ACCORDING TO DEVICE BEING USED.
MIN. 8m
ABOVE GRADE
NC
13
VA
NO
NO
PIPING
INSTR.
NO
NO
PIPING
INSTR.
PIPING
INSTR.
3/4"
S-8
75
8
3/4"
3/4"
3" BLIND
FLANGE
3/4" PIPE
PIPING
INSTR.
3/4" VALVE
3/4"
CWR
CWS
PIPING
INSTR.
5
CWR
CWR
3/4"
IG
PI
PI
3/4"
FLOW
16
3/4"
TG
LOWER PRESSURE
SIDE CLASS
MAIN LINE
CLASS
PIPING
INSTR.
3/4"
3/4"
MIN. 8m
ABOVE GRADE
AND AWAY FROM
OPERATING
PLATFORM
TO SAMPLE COOLER
3/4"
VA
3/4"
PIPING
INSTR.
PIPING INSTR.
NO
PIPING
INSTR.
NO
3/4"
MIN. DISTANCE
FOR ACCESS
TG
AU
16
13
3/4"
SAMPLE POINT
ACTUAL DETAIL ARRANGEMENT
SEE DETAIL
TO RIGHT
NO
FLOW
12
3/4"
13
7
3/4"
FL
3/4"
3/4"
11
SAMPLE BOTTLE
(BY SHELL)
CWS
3/4" VALVE
SAMPLE BOMB
(BY SHELL)
CWS
MIN.
B
S-9
S-12
17
17
17
S-5
S-9
S-5
S-9
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
3/4"
3/4"
3/4"
3/4"
REV
3/4"
S-12
S-12
SWEET/SOUR HYDROCARBON GAS/LIQUID
45C AND ABOVE
SHELL CANADA
QUEST CCS PROJECT
A
R
200.0000.000.041.012
REV.
200.012
S-5
12
3/4"
SAMPLE POINT
ACTUAL DETAIL ARRANGEMENT
APPLICATION AND DESCRIPTION
NO
NO
INST.
PIPING
PIPING SPECS
(UAB, UAZ, UAY, UJB, ULB)
X"
3/4"
X"
3/4"
X"
3/4"
3/4"
INST.
PIPING
INST.
PIPING
PIPING CLASSES
(150#, 300#, 600#)
PIPING CLASSES
(900#, 1500#, 2500#)
INST.
PIPING
3/4"
PURGE
BLEED
X"
1/2"
X"
3/4"
BLEED
X"
3/4"
INST.
PIPING
INST.
PIPING
X"
1/2"
PURGE
BLEED
1/2"
X"
INST.
PIPING
BLEED
1/2"
1. FOR GENERAL NOTES AND DETAILS SEE DWGS. 245.0311.000.053.005, 006, 007,
008, 009, 010, 011, 012, 013, 018 AND 019.
2. LEGEND:
3/4"
- 3/4" 'PHOENIX' DOUBLE BLOCK & BLEED GAUGE VALVE.
1/2"
- 1/2" 'SWAGELOK' DOUBLE BLOCK & BLEED GAUGE VALVE.
3. EXCEPT PIPING SPECS, UAB, UAZ, UAY, UJB, ULB.
4. PIPING/INSTRUMENTATION SCOPE BREAKS ARE NOT TO BE SHOWN ON THE P&ID'S.
DETAILS ON THESE CONNECTIONS SHOW IMPLIED BREAKS.
PURGE
PIPING CLASSES
(150#, 300#, 600#)
PIPING CLASSES
(900#, 1500#, 2500#)
1"
1"
INST.
PIPING
3/4"
3/4"
TT
2"
2"
TT
PIPING CLASSES
(150#, 300#, 600#)
1-1/2"
PIPING CLASSES
(900#, 1500#, 2500#)
TT
INST.
PIPING
PIPING SPECS
(150#, 300#, 600#, 1500#)
INST.
PIPING
PIPING SPECS
(1500#, 2500#)
ANALYZER CONNECTIONS
AT
3/4"
PIPING
INST.
X"x3/4"
PIPING
INST.
X"x3/4" 3/4"
PIPING SPECS
(UAB, UAZ, UAY, UJB, ULB)
(FOR VESSEL CONNECTION)
AT
2"
PIPING CLASSES
3
(150#, 300#, 600#, 900#, 1500#)
(FOR VESSEL CONNECTION)
2"
INST.
PIPING
PIPING SPECS
(150# TO 2500#)
INST.
PIPING
PIPING SPECS
(900# TO 2500#)
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
PIPING
INST.
X"x3/4"
REV
PIPING CLASSES
(150#, 300#, 600#, 900#, 1500#)
(FOR VESSEL CONNECTION)
SHELL CANADA
QUEST CCS PROJECT
A
PURGE
IF REQUIRED
3/4"
PIPING
INST.
PIPING CLASSES
(1500#, 2500#)
(FOR VESSEL CONNECTION)
SCALE: NONE
SHELL DWG NO.:
200.0000.000.041.013
REV.
200.013
X"x3/4"
PURGE
D
X"
3/4"
3/4"
INST.
PIPING
1/2"
PIPING
INST.
1/2"
3"
3"
INST.
PIPING
BLEED
PIPING CLASSES
(150#, 300#, 600#)
3"
3"
BLEED
PIPING SPECS
(UAB, UAZ, UAY, UJB, ULB)
3"
1/2"
3"
PIPING
INST.
X"x3/4" 3/4"
3/4"
3"
3"
PIPING
INST.
1/2"
3/4"
3/4"
X"
3/4"
X"x3/4" 3/4"
BLEED
PIPING
INST.
1/2"
PIPING
INST.
PIPING
INST.
BLEED
1. FOR GENERAL NOTES AND DETAILS SEE DWGS 245.0311.000.053.005, 006, 007,
008, 009, 010, 011, 012, 013, 018 AND 019.
2. LEGEND:
3/4"
- 3/4" "PHOENIX" DOUBLE BLOCK & BLEED GAUGE VALVE.
PIPING CLASSES
(600# H2 SERVICE, 900#, 1500#)
3/4"
3"
3"
3"
3"
1/2"
X"
PIPING
INST.
PIPING
INST.
1/2"
PURGE
3/4"
BLEED
INST.
PIPING
4
X"
3/4"
3/4"
INST.
PIPING
PURGE
BLEED
PIPING CLASSES
(150#, 300#, 600#, 900#, 1500#)
PIPING CLASSES
(1500# , 2500#)
PIPING
INST.
3/4"
3"
3"
3"
3"
1/2"
3/4"
PURGE
PIPING
INST.
1/2"
BLEED
PURGE
IF REQUIRED
X"
INST.
PIPING
4
X"
3/4"
3/4"
INST.
PIPING
PURGE
IF REQUIRED
PURGE
BLEED
PIPING CLASSES
(1500#, 2500#)
PIPING CLASSES
(1500#, 2500#)
(1500#, 2500#)
WITH UTILITY CONNECTION
PIPING
INST.
3/4"
3/4"
2"
2"
MAG/
CAPACITANCE/
GUIDED WAVE
PIPING
INST.
3/4"
PIPING
INST.
3/4"
3/4"
PIPING CLASSES
(600# H2 SERVICE, 900#, 1500#)
REV
ISSUED
DATE
DESCRIPTION
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
PURGE
1/2"
3/4"
V
2"
3/4"
2"
SHELL CANADA
V
INST.
PIPING
2"
BLEED
PIPING
INST.
INST.
PIPING
3/4"
2"
PIPING CLASSES
(600# H2 SERVICE, 900#, 1500#)
2"
2"
PIPING CLASSES
(150#, 300#, 600#)
200.0000.000.041.014
REV.
200.014
3"
GWR
3/4"
3"
GWR
PIPING
INSTR.
3"
PIPING SPECS
(UAB, UAZ, UAY, UJB, ULB)
BY
PIPING CLASSES
(150#, 300#, 600#)
PIPING
INST.
3"
3/4"
1/2"
3/4"
3"
PIPING CLASSES
(150#, 300#, 600#)
2"
PIPING
INST.
BLEED
PIPING
INSTR.
PURGE
1/2"
PIPING
INST.
PURGE
2"
BLEED
3"
3"
2"
PIPING SPECS
(UAB, UAZ, UAY, UJB, ULB)
3/4"
1/2"
3/4"
3"
2"
MAG/
CAPACITANCE/
GUIDED WAVE
BLEED
PURGE
2"
3/4"
INST.
PIPING
3/4"
PURGE
IF REQUIRED
2"
3/4"
2"
PIPING
INST.
2"
2"x3/4"
MAG/
CAPACITANCE/
GUIDED WAVE
PIPING
INST.
3/4"
2"
3/4"
X"x2"
3/4"
X"x3/4"
PIPING
INST.
3/4"
IF REQUIRED
PURGE
PIPING
INST.
FT
1. FOR GENERAL NOTES AND DETAILS SEE DWGS. 245.0311.000.053.005, 006, 007
008, 009, 010, 011, 012, 013, 018 AND 019.
2. LEGEND:
3/4"
- 3/4" "PHOENIX" DOUBLE BLOCK & BLEED GAUGE VALVE.
1/2"
- 1/2" "SWAGELOK" DOUBLE BLOCK & BLEED GAUGE VALVE.
3. PIPING/INSTRUMENTATION SCOPE BREAKS ARE NOT TO BE SHOWN ON THE P&ID'S.
DETAILS ON THESE CONNECTIONS SHOW IMPLIED BREAKS.
3/4"
INST.
PIPING
PIPING
INST.
INST.
PIPING
3/4"
PIPING
INST.
INST.
PIPING
3/4"
3/4"
3/4"
INST.
PIPING
PIPING
INST.
1/2" OR 3/4"
1/2" OR 3/4"
INST.
PIPING
3/4"
FT
PIPING
INST.
FE
FT
PIPING CLASSES
(150#, 300#, 600#, 900#)
PIPING CLASSES
(1500#, 2500#)
FE
1/2" OR 3/4"
1/2" OR 3/4"
INST.
PIPING
PIPING
INST.
INST.
PIPING
PIPING
INST.
PIPING
INST.
3/4"
PURGE
IF REQUIRED
3/4"
INST.
PIPING
PIPING
INST.
FE
PIPING CLASSES
(1500#, 2500#)
PIPING CLASSES
FT
FT
3/4"
PIPING
INST.
FE
PIPING
INST.
PURGE
IF REQUIRED
PIPING
INST.
3/4"
1/2" OR 3/4"
INST.
PIPING
3/4"
PURGE
IF REQUIRED
INST.
PIPING
3/4"
1/2" OR 3/4"
INST.
PIPING
PIPING
INST.
FE
FT
PIPING CLASSES
PIPING CLASSES
(150#, 300#, 600#, 900#, 1500#)
FT
FT
FT
PIPING
INST.
X"
PIPING
INST.
2"
1/2"
2"
3/4"
INST.
PIPING
2"
1/2"
2"
2"
PIPING
INST.
INST.
PIPING
BLEED
3/4"
3/4"
FE
BLEED
X"
BLEED
3/4"
PIPING
INST.
3/4"
3/4"
PIPING
INST.
INST.
PIPING
1/2"
2"
INST.
PIPING
2"
PIPING
INST.
1/2"
2"
BLEED
3/4"
3/4"
INST.
PIPING
PIPING
INST.
FE
REV
FE
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
PIPING CLASSES
(150#, 300#, 600#)
INST.
PIPING
PIPING
INST.
3/4"
3/4"
PURGE
X"
BLEED
BLEED
3/4"
INST.
PIPING
3/4"
PURGE
PIPING
INST.
1/2"
PURGE
BLEED
A
PURGE
PIPING
INST.
X"
FE
FE
PIPING CLASSES
(150#, 300#, 600#)
PIPING CLASSES
(900#, 1500#)
FT
SHELL CANADA
3/4"
PIPING
INST.
PIPING CLASSES
(150#, 300#, 600#, 900#, 1500#)
1/2"
PIPING
INST.
200.0000.000.041.015
REV.
200.015
3/4"
PIPING CLASSES
(900#, 1500#)
1/2"
2"
BLEED
PIPING
INST.
INST.
PIPING
2"
PIPING
INST.
FE
1/2"
2"
INST.
PIPING
2"
INST.
PIPING
3/4"
FT
3/4"
FT
3/4"
3/4"
PIPING CLASSES
(1500#, 2500#)
FT
FT
1/2"
INST.
PIPING
BLEED
2"
BLEED
1/2"
2"
1/2"
PURGE
IF REQUIRED
2"
2"
PURGE
IF REQUIRED
PIPING
INST.
X"
FE
PIPING CLASSES
(1500#, 2500#)
FT
FT
BLEED
BLEED
BLEED
BLEED
INST.
PIPING
1/2"
1/2"
1/2"
1/2"
BLEED
BLEED
BLEED
BLEED
3/4"
3/4"
2"
3/4"
3/4"
3/4"
3/4"
2"
2"
3/4"
INST.
PIPING
2"
1/2"
3/4"
2"
1/2"
2"
1/2"
2"
1/2"
FT
2"
FT
X"
PIPING
INST.
PIPING
INST.
FE
FE
PIPING CLASSES
(150#, 300#, 600#)
FT
PIPING CLASSES
(900#, 1500#)
FT
1/2"
1/2"
1/2"
1/2"
BLEED
BLEED
BLEED
BLEED
3/4"
3/4"
FT
INST.
PIPING
PURGE
PURGE
FT
1/2"
1/2"
1/2"
1/2"
BLEED
BLEED
BLEED
BLEED
3/4"
3/4"
3/4"
3/4"
PURGE
PURGE
X"
PIPING
INST.
PURGE
3/4"
PURGE
INST.
PIPING
3/4"
PURGE
PURGE
X"
PIPING
INST.
PIPING
INST.
FE
FE
PIPING CLASSES
(150#, 300#, 600#)
FT
PIPING CLASSES
(900#, 1500#)
REV
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
FT
1/2"
1/2"
1/2"
1/2"
BLEED
BLEED
BLEED
BLEED
3/4"
3/4"
PURGE
IF REQUIRED
X"
PIPING
INST.
3/4"
PURGE
IF REQUIRED
PURGE
IF REQUIRED
INST.
PIPING
3/4"
SHELL CANADA
PURGE
IF REQUIRED
A
R
X"
PIPING
INST.
FE
SCALE: NONE
SHELL DWG NO.:
PIPING CLASSES
(1500#, 2500#)
200.0000.000.041.016
REV.
200.016
PIPING
INST.
PIPING
INST.
HOA(TOA)
HIS
HOA(TOA)
SIS
ES
WINDING TEMP
SIS
VIB
VIB
VIB
TEMP
TEMP
TEMP
MCC
HOA(TOA)
VIB
TEMP
HOA(TOA)
HIS
HS
HSZ
A/B
HIS
HOA(TOA)
HOA(TOA)
HOA(TOA)
HS
SIS
SIS
CONTROL
CONTROL
MONITORING
MONITORING
B
MCC
ES
WINDING TEMP
MCC
WINDING TEMP
ES
HS
VIB
VIB
VIB
VIB
TEMP
TEMP
TEMP
TEMP
REV
'A' MOTOR
12/02/10
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
'B' MOTOR
SHELL CANADA
QUEST CCS PROJECT
A
R
SCALE: NONE
SHELL DWG NO.:
200.0000.000.041.XX1
REV.
200.XX1
VFD
WINDING TEMP
MONITORING
CONTROL
ES
HS
3/4"
3/4"
ANTI-FOAM
ET 10
38
3/4"-KP-246005-PJG(0.4)
246.014
12286
ET 10 FREE DRAINING
38
ET 10
38
TO V-24218
FROM P-24606
10
FREE DRAINING
CSO
12039
3/4" 3/4"
3/4"-KP-241001-PJG(0.4)
240.030
FL
6"-FL-241020-PAC
PAC
HJE(0.4)
S-4
12967
6"x3"
2"-P-241057-HJE(0.4)
SP
001
3/4" 3/4"
242.021
12981
TO UC-246002
I
104
HH
TT
030
16"-P-246080-DAG
LEAN AMINE
12"-P-241061-DAG
1-1/2"
16"x12" ET 10
50
246.011
12642
ET 10
50
241.022
TO V-24119
12"
4"
PJG(0.4)
DAG
MP-001
DETAIL 'A'
SP
007
FV
075
12"x8"
HOLDS:
12"-P-241062-DAE
MIN
12"-P-241063-DJE(0.4) 16"x12"
36"
MW
16"
12"x8" FC
D
3"
PDT
064
8"
V-24118
3"
25
LEAN AMINE
242.021
CSC
12633
8"
FO
3/4"
FROM P-24602A/B/C
FT
075
12
12055
FYE
075
3/4"
TI
030
H2 RAW GAS
3/4"
3/4"
FROM LX-246001
12"-P-241056-HJE(0.4)
DAE
DJE(0.4)
FC
075
246.002
E
451
DAG
DAE
SET POINT
12206
H
38
FREE DRAINING
10
RV
023
CSO
ANTI-FOAM
CSC
V-24118
AMINE ABSORBER 1
SIZE:
DESIGN PR. & TEMP:
MATERIAL(VESSEL/INTERNALS):
INSULATION TYPE/THK:
TRIM:
FIRE
1-1/2H3
SET@
3500 kPa-g
2"x1-1/2"
PDI
064
TO V-24218
12"-P-241074-DAG
DETAIL "A"
INJECTION QUILL
E
450
E
453
HZTE
015
I
104
FO
ET 38
75
I
102
12"x8" FO 12"x8"14"x12"
E
453
HIC
014
HZTE
014
TO HMU 1 PSA
HV
015
3"
3/4"
2"
SWING
ELBOW
2"
HHLL=4400 mm
NLL=2800 mm
24"
MW
2"
3"
LG
155
03/01/11
01/10/11
12/02/10
ISSUED
DATE
DESCRIPTION
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
2"-P-241065-DJE(0.4)
4"
12"x8"
3/4"
TT
031
XV
020
16"x12" 8"-P-241064-DJE(0.4)
16"
3/4"
FO
8"
6"
FC
LV
155
12
8"x6"
8"x6"
1-1/2"
FC
D
SHELL CANADA
8"-P-241064-DJE(0.4)
ET 10
50
8
RICH AMINE
12635
242.021
TO E-24602A/B
TWO PHASE FLOW
R
VACUUM TRUCK
SP
004
241.0000.000.041.021
REV.
241.021
S-9
4"-P-241066-DJE(0.4)
SP
003
BY
3/4"
4000 mm
3/4"
1"
XZTE
020
1"-SL-241XXX-SAB
TI
031
3/4"
3/4"
XYE
020
4"
12716
1"-SCL-241XXX-SAB
04/20/11
XZI
020
E
450
REV
A/S
3/4"
240.029
SCL
N/A
ET 10
LLLL=300 mm
3"
12715
LI
155B
LT
155B
2"x3/4"
3"-SL-240020-SAB
LC
155
06/13/11
2"
SO
240.029
SL
LHS
155
MAG
3"
3/4"
3"
SWING
ELBOW
LI
155A
LT
155A
HLL=3500 mm
LLL=1900 mm
2"
3/4"
2"
DP
2"
3/4"
2"
3/4"
3"
3"
3/4"
LL
GWR
3/4"
2"
HJE(0.4)
ULB
LTE
154
3/4" 3/4"
2"-GI-240022-ULB
START-UP
E
450
3/4"
D
CSC
E
451
PP
MIN
HH
3/4"
MIN
4
2"
18"
3/4"
FC
18"x14"
MIN
HV
014
SP
002
13
2"
FROM HMU 1
12717
241.022
3/4"
14"
ET 38
14"-P-241054-HJE(0.4)
75
240.028
GI
12054
24"
MW
3/4"
I
102
3/4"
241.009
BYPASS
H2 RAW GAS
HYE
014
FO
H2 RAW GAS
HIC
015
E
450
3"
11
FLOW
14"-P-241055-HJE(0.4)
14"x12"
8"
14
I
103
HYE
015
11
14"-P-241055-HJE(0.4)
PJG(0.4)
DAG
V-24119
ABSORBER 1 WASH WATER VESSEL
SIZE:
DESIGN PR. & TEMP:
MATERIAL(VESSEL/INTERNALS):
INSULATION TYPE/THK:
TRIM:
1
7
FI
074A
f(x)
FI
074B
HOLDS:
BYPASS
H
PC
067
AI
016
CO2
I
101
HJE(0.4)
PAC
HOLD
PV
067
10"-FL-241021-PAC
6" 10"x6"
3/4"
FC
TSO
FREE DRAINING
FT
076
246.022
2"-SCH-246003-SAG
2"x1"
ET 10
38
FV
076
2"x1"
1"
12"
AP
016B
14"x12"
3/4"
3/4" 3/4"
3/4" 3/4"
FREE DRAINING
INST
PIPING
AP
016A
INST
PIPING
TT
032
FT
074
C
1-1/2"
H2 RAW GAS
ET 38
14"-P-241058-HJE(0.4)
75
TO HMU 1 PSA
DETAIL "B"
2"
3"
3"
CSC
2"x1"
MIN
8
3"
3"x2"
1"
PDI
066
PDT
066
24"
MW
V-24119
9
2"-SCH-241XXX-SAD
7
CSC
4"
SAG
SAD
24"
MW
4"x3"
ET 10
38
3"-P-241XXX-HJE(0.4)
3"-P-241073-PJE(0.4)
CIRCULATING WATER
241.023
L
H
E
453
E
452
DP
HH
LL
3/4" 3/4"
HHLL=2450 mm
2"
LTE
159
6
3"
2"
2"
MAG
LG
157
24"
MW
HLL=2300 mm
2"
NLL=1050 mm
3"
3"
LLL=870 mm
2"
LLLL=300 mm
2"
3"
3"
LT
157A
LI
157A
DP
LT
157B
3/4"
3"
2"
3"
3/4"
3"
2"
3/4"
LI
159
2"
3/4"
LI
157B
06/13/11
04/20/11
03/01/11
01/10/11
12/02/10
LC SIGNAL
LHS
157A
12409
241.023
REV
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
TO LC-157
3/4"
LI
156
3"
14"
3/4"
FREE DRAINING
3"
3/4" 3/4"
14"x12"
3/4"
FROM V-24118
3/4"
241.021
H
38
12"-P-241056-HJE(0.4)
PP
3/4"
12055
GWR
3/4"
LTE
156
12408
FROM E-24129
H2 RAW GAS
241.009
24"
MW
FC
3/4"
FROM P-24609A/B
2"x1"
13045
PJE(0.4)
12968
FO
WASH WATER
PT
065
XV
019
HJE(0.4)
TO V-24219
AP
016C
3/4" 3/4"
240.030
FL
FYE
076
SAD
HJE(0.4)
12969
3/4"
242.022
2"-SCH-242XXX-SAG
2"-SCH-241XXX-SAG
WASH WATER
FC
076
DETAIL "B"
SAMPLE QUILL
3/4" 3/4"
FO
12"
V
3"
TO FX-246076
AE
016
A/S
3/4"
E
453
13030
XYE
019
FC
CO2 RICH
FLOW
FREE DRAINING
246.022
PI
065
E
453
XZTE
019
CO2 LEAN
12061
E
450
PT
067
TI
032
AIT
016
240.030
FL
ET 10
50
ET 38
63
6"-P-241059-HJE(0.4)
FLOW SIGNAL
SO
7860 mm
6"
ET 10
50
6"-P-241067-PJE(0.4)
SHELL CANADA
CIRCULATING WATER
12407
241.023
TO P-24108A/B
3"
D
R
241.0000.000.041.022
REV.
FROM HMU 1
FROM FC-377
FX
074A
ET 38
75
14"-P-241055-HJE(0.4)
241.009
241.022
241.021
12054
FC SIGNAL
FX
074B
H2 RAW GAS
FHS
074
SET POINT
TO PSA LOGIC
E-24129
ABSORBER 1 CIRCULATING WATER COOLER
RATED DUTY:
SURFACE AREA:
TEMA TYPE:
DESIGN PRESS:
DESIGN TEMP:
MATERIAL:
INSULATION TYPE/THK:
TRIM:
LC SIGNAL
12409
LC
157
241.022
FROM LHS-157A
0.2 MW
37.9 m^2
BEU
SHELL
3900 kPa-g / HV
60 C / 150 C
CS + 3 mm 304L SS CLAD
/
6
P-241082-PJE(0.4)
TUBE
3010 kPa-g /
58 C /
SUPER DUPLEX 2507 + 0.38 mm CA
/
6
CWR-241004-PJE(0.4)
LHS
157B
2"-P-242076-PJE(0.4)
PURGE WATER
242.023
12638
FROM E-24229
HOLDS:
LV
157A
2"x1" 1"
12407
241.022
TW
035
XV
018
ET 10
50
6"-P-241067-PJE(0.4)
PT
070
S-8
3/4" 3/4"
CIRCULATING WATER
3/4"
SP
005
FO
XZTE
018
6"x4"
246.006
1-1/2"
V
6"x4"
ET 10
38
4"-CWR-241003-UAB
3"-P-241072-PJE(0.4)
242.023
TO HEADER
CSO
FC
FROM V-24119
12637
PI
070
3/4" 3/4"
3/4"
A/S
PURGE WATER
2"x1"
FC
3/4" 3/4"
3"-P-241076-PJE(0.4)
TO V-24602
3/4"
NC
RS
LV
157B
3"x2"
ET 10
38
2"-P-241076-PJE(0.4)
2"
3/4"
XYE
018
FC
2"x1" 1"
2"-P-241075-PJE(0.4)
E
452
2"x1"
XZI
018
3/4"
UAB
PJE(0.4)
TG
033
3"x2"
ET 10
38
3"-P-241073-PJE(0.4)
3"
3/4"
TO V-24119
3"x2"
4"-CWS-242003-UAB
12618
FROM HEADER
6"x3"
D
BACK FLUSH
1-1/2"
6"x3"
TG
034
ET 10
50
SEL
LOCAL/
REMOTE
SI
016
VFD
3/4"
3/4"
TO
GRADE
PP
SP
006A
3/4"
P-24108A
VFD
FAULT
XL
017
LOCAL/
REMOTE
SI
017
PP
04/20/11
03/01/11
01/10/11
12/02/10
B
REV
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
3/4"
TO
GRADE
PP
SP
006B
3/4"
3/4
"
D
D
D
3/4"
3"x2"
6"x3"
3/4"
3/4"
3/4"
XA
017
06/13/11
3"x2"
6"x3"
VFD
D
PP
E
452
HOA
ET 10
N/A
XL
016
HS
017 A
MIN.
VFD
FAULT
I
100
3/4"
XA
016
R/S
3"-P-241071-PJE(0.4)
HIS
017
ET 10
50
HOA
6"-P-241069-PJE(0.4)
E
452
HS
016A
N/A10
ET
3/4"
I
100
ET 10
50
R/S
MIN.
HIS
016
P-24108B
SHELL CANADA
3/4
"
D
A
R
P-24108A /B 7
ABSORBER 1 CIRCULATING WATER WASH PUMPS
MATERIAL:
INSULATION TYPE/THK:
TRIM:
39.1 m^3/hr
322 kPa
5.6 kW
CASING
INTERNALS
316 SS
316 SS
/
6
P-241083-PJE(0.4)
241.0000.000.041.023
REV.
241.023
RATED FLOW:
DIFF. PR.:
DRIVER:
HS
XXX
3"-P-241070-PJE(0.4)
12408
3"-P-241073-PJE(0.4)
1-1/2"
6"x3"
6"x3"
6"-P-241068-PJE(0.4)
241.022
ET 10
38
UAB
FT
077
3/4"
CIRCULATING WATER
LL
PJE(0.4)
RS
I
103
3"-P-241077-PJE(0.4)
FC
077
3"-P-241072-PJE(0.4)
E-24129
2
FIRE
1-1/2H3
SET@
3500 kPa-g
2"x1-1/2"
ET 10
38
10
12982
2"-P-242057-HJE(0.4)
SP
001
TO UC-246002
H
38
FREE DRAINING
246.002
12403
FROM LX-246001
3/4"
FROM P-24602A/B/C
PJG(0.4)
DAG
12"-P-241074-DAG
DETAIL 'A'
SP
007
12"
12"x8"
D
MIN
12"-P-242062-DAE
12"x8"
3/4"
241.021
12633
12
ET 10
50
3/4"
LEAN AMINE
TO V-24219
HOLDS:
8" FV
075
FO
MP-001
242.022
12064
FYE
075
FT
075
H2 RAW GAS
4"
FC
075
E
451
12"-P-242063-DJE(0.4)
16"x12"
36"
MW
16"
FC
DAE DJE(0.4)
PDT
064
8"
CSC
DAG DAE
3/4"
SET POINT
12"-P-242056-HJE(0.4)
PDI
064
V-24218
3"
25
DETAIL "A"
INJECTION QUILL
E
450
PJG(0.4)
DAG
E
453
HZTE
015
I
104
11
FO
ET 38
75
14"-P-242055-HJE(0.4)
HZTE
014
TO HMU 2 PSA
HV
015
3"
9
14"-P-242054-HJE(0.4)
FC
2"
3/4"
2"
LL
GWR
3"
2"
2"
2"
3/4" 3/4"
LTE
154
3/4"
HJE(0.4)
ULB
HH
2"
HHLL=4400 mm
SWING
ELBOW
DP
HLL=3500 mm
NLL=2800 mm
2"
2"
2"
3"
LG
155
3"
3/4"
XYE
020
12712
03/01/11
01/10/11
12/02/10
REV
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
8"
8"-P-242064-DJE(0.4)
4"-P-242066-DJE(0.4)
TT
031
6"
FC
8"x6" FC 8"x6"
10"x8"
4"
SP
004
246.001
12634
FROM V-24118
241.021
FROM V-24118
TWO PHASE FLOW
RICH AMINE
RICH AMINE
SP
003
VACUUM TRUCK
ET 10
50
8"-P-241064-DJE(0.4)
S-9
10"-P-242064-DJE(0.4)
12
3/4"
SHELL CANADA
LV
155
1-1/2"
3/4"
12"x8"
XV
020
3/4"
4"
16"
16"x12"
3/4"
FO
XZTE
020
4000 mm
3/4"
1"-SL-242XXX-SAB
1"-SCL-242XXX-SAB
04/20/11
TI
031
3/4"
240.029
SCL
3"
N/A
ET 10
LLLL=300 mm
SO
A/S
12711
XZI
020
E
450
2"
2"x3/4"
3"-SL-240018-SAB
06/13/11
MAG
240.029
SL
LI
155B
LT
155B
3/4"
3/4"
SWING
ELBOW
LC
155
LHS
155
24"
MW
3/4"
LLL=1900 mm
LI
155A
LT
155A
3/4"
2"-GI-240020-ULB
START-UP
PP
3/4"
E
450
CSC
V
18"
3/4"
E
451
MIN
2"
18"x14"
MIN
MIN
15
ET 38
75
3/4"
13
SP
002
3/4"
HV
014
3/4"
FO
14"
242.022
12065
24"
MW
3/4"
3/4"
I
102
12713
H2 RAW GAS
HYE
014
3"
11
240.028
GI
14"-P-242055-HJE(0.4)
BYPASS
E
450
HIC
014
FROM HMU 2
HIC
015
I
102
E
453
242.009
FLOW
14"x12"
8"
14
I
103
HYE
015
H2 RAW GAS
242.0000.000.041.021
REV.
246.011
PAC
HJE(0.4)
ET 10
38
10
CSO
3/4"
12063
242.021
FREE DRAINING
S-4
FROM P-24606
240.030
FL
6"-FL-242020-PAC
CSC
3/4"-KP-241001-PJG(0.4)
6"x3"
CSO
241.021
12967
FREE DRAINING
ANTI FOAM
RV
023
3/4" 3/4"
3/4" 3/4"
V-24218
AMINE ABSORBER 2
3/4"
V-24219
ABSORBER 2 WASH WATER VESSEL
SIZE:
DESIGN PR. & TEMP:
MATERIAL(VESSEL/INTERNALS):
INSULATION TYPE/THK:
TRIM:
FHS
074
SET POINT TO
PSA LOGIC
FI
074B
3
FI
074A
FC SIGNAL
FX
074B
242.009
FROM FC-377
f(x)
FROM HMU 2
ET 38
75
14"-P-242055-HJE(0.4)
BYPASS
AI
016
PC
067
6" 10"x6"
ET 10
50
3/4"
FC
TSO
10"-FL-242021-PAC
FREE DRAINING
240.030
FL
ET 38
75
AP
016B
3/4" 3/4"
PT
065
14"x12"
INSTR
PIPING
12707
3/4" 3/4"
AP
016A
TT
032
FT
074
C
1-1/2"
H2 RAW GAS
ET 38
14"-P-242058-HJE(0.4)
75
TO HMU 2 PSA
DETAIL 'B'
3/4"
2"
3"
3"
FYE
076
24"
MW
2"x1"
ET 10
38
2"x1"
2"-SCH-242XXX-SAD
8
3"
3"x2"
FC
D
2"x1"
1"
3/4"
FROM P-24609A/B
2"x1"
3/4"
2"-SCH-241XXX-SAG
FV
076
1"
SAD HJE(0.4)
DETAIL 'B'
SAMPLE QUILL
24"
MW
V-24219
MIN
CSC
SAG SAD
PDI
066
PDT
066
HJE(0.4)
FT
076
4"
24"
MW
4"x3"
ET 10
38
3"-P-242XXX-HJE(0.4)
3"-P-242073-PJE(0.4)
CIRCULATING WATER
242.023
14"x12"
3"
3/4"
HHLL=2450 mm
2"
2"
E
452
HH
6
LL
2"
LTE
159
D
24"
MW
2"
NLL=1050 mm
5
3"
3"
2"
LLL=870 mm
3"
2"
LG
157
2"
3/4"
E
453
3/4"
MAG
HLL=2300 mm
DP
3/4"
LI
159
3"
3"
3"
LT
157A
LT
157B
LI
157B
06/13/11
04/20/11
03/01/11
01/10/11
12/02/10
LI
157A
DP
REV
LC SIGNAL
LHS
157A
12413
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
242.023
TO LC-157
LLLL=300 mm
3/4"
LI
156
3"
2"
3/4"
3"
3/4"
2"
3/4"
3/4"
FREE DRAINING
3"
14"
3/4"
FROM V-24218
3/4"
242.021
H
38
12"-P-242056-HJE(0.4)
FLOW
PP
3/4"
12064
GWR
3/4" 3/4"
LTE
156
INST.
PIPING
12411
FROM E-24229
H2 RAW GAS
242.009
CSC
FO
241.022
12"
AP
016C
240.030
FL
3/4" 3/4"
PJE(0.4)
TO FX-246076
12969
XZTE
019
PI
065
FC
12"
3"
FC
076
13031
WASH WATER
FLOW SIGNAL
246.022
FO
FREE DRAINING
E
453
019
XV
HOLDS:
CO2 RICH
12146
A/S
3/4" 3/4"
FREE DRAINING
6"-P-242059-HJE(0.4)
XYE
019
CO2 LEAN
AE
016
E
450
PT
067
TI
032
AIT
016
HJE(0.4) PAC
E
453
I
101
HOLD
PV
067
CO2
SO
7860 mm
6"
ET 10
50
6"-P-242067-PJE(0.4)
SHELL CANADA
CIRCULATING WATER
12412
242.023
TO P-24208A/B
3"
D
R
242.0000.000.041.022
REV.
242.021
242.022
12065
3/4" 3/4"
H2 RAW GAS
FX
074 A
E-24229
ABSORBER 2 CIRCULATING WATER COOLER
RATED DUTY:
SURFACE AREA:
TEMA TYPE:
DESIGN PRESS:
DESIGN TEMP:
MATERIAL:
INSULATION TYPE/THK:
TRIM:
LC SIGNAL
12413
LC
157
242.022
TUBE
3010 kPa-g /
58 C /
SUPER DUPLEX 2507 + 0.38 mm CA
/
6
WR-242004-PJE(0.4)
LHS
157B
HOLDS:
INSTRUMENT SIZING TO BE CONFIRMED DURING DETAILED ENGINEERING.
CONFIRM AVAILABILITY OF DCS AND SIS INTERLOCK SEQUENCE NUMBERS
ADDED FOR QUEST.
LV
157A
FROM LHS-157A
0.2 MW
37.9 m^2
BEU
SHELL
3900 kPa-g / HV
60 C / 150 C
CS + 3 mm 304L SS CLAD
/
6
P-242082-PJE(0.4)
1"
FC
3/4"
2"x1"
2"x1"
ET 10
38
D
LV
157B
2"-P-242076-PJE(0.4)
PURGE WATER
12638
241.023
TO V-24602
1"
3/4" 3/4"
SP
005
3/4" 3/4"
PI
070
FC
3"-P-242073-PJE(0.4)
6"x3"
1-1/2"
3"x2"
6"x3"
RS
3"-P-242077-PJE(0.4)
3"x2"
FROM HEADER
4"-CWS-240XXX-UAB
ET 10
38
4"-CWS-242003-UAB
241.023
TO E-24129
6"x3"
6"x3"
HS
E
452
ET 10
50
HIS
017
XA
016
VFD
FAULT
XL
016
LOCAL/
REMOTE
SI
016
VFD
3/4"
PP
3/4"
3/4"
E
452
SP
006B
XA
017
VFD
FAULT
XL
017
LOCAL/
REMOTE
SI
017
06/13/11
04/20/11
03/01/11
01/10/11
12/02/10
B
REV
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
3/4"
D
TO
GRADE
PP
3/4"
3"x2"
SHELL CANADA
3/4"
3/4
"
D
D
D
P-24208A
HOA
PP
3/4"
3/4"
6"x3"
3/4
"
D
HS
017A
VFD
3"x2"
6"x3"
I
100
3/4"
TO
GRADE
PP
SP
006A
R/S
3/4"
3/4"
HOA
ET 10
50
HS
016A
6"-P-242069-PJE(0.4)
I
100
N/A
R/S
SEL
ET 10
HIS
016
3/4"
240.003
1-1/2"
TG
034
ET 10
50
3"-P-242073-PJE(0.4)
6"-P-242068-PJE(0.4)
PJE(0.4)
UAB
6"-CWS-240015-UAB
D
BACK FLUSH
3/4"
TO V-24219
ET 10
50
FT
077
MIN.
12411
ET 10
38
LL
3"-P-242070-PJE(0.4)
CIRCULATING WATER
PJE(0.4)
3"
TG
033
UAB
E-24229
I
103
242.022
D
6
FC
077
CSO
NC
FROM V-24219
12619
P-24208B
A
R
P-24208A /B 7
ABSORBER 2 CIRCULATING WATER WASH PUMPS
RATED FLOW:
DIFF. PR.:
DRIVER:
MATERIAL:
INSULATION TYPE/THK:
TRIM:
39.1 m^3/hr
322 kPa
5.6 kW
CASING
INTERNALS
316 SS
316 SS
/
6
P-242083-PJE(0.4)
242.0000.000.041.023
REV.
6"-P-242067-PJE(0.4)
241.023
242.023
242.022
3/4"
ET 10
50
ET 10
N/A
12412
4"-CWR-241003-UAB
FROM E-24129
MIN.
CIRCULATING WATER
XV
018
ET 10
50
6"x4"
3"-P-242072-PJE(0.4)
3"-P-242071-PJE(0.4)
3/4" 3/4"
FO
240.003
4"-CWR-242XXX-UAB
1-1/2"
6"x4"
TW
035
PT
070
6"-CWR-242003-UAB
2"
A/S
XZTE
018
ET 10
50
S-8
XYE
018
2"x1"
RS
E
452
FC
2"x1"
3/4"
2"-P-242075-PJE(0.4)
XZI
018
E-24602A/B
LEAN / RICH AMINE EXCHANGER
64.5 MW (TOTAL)
1521.0 m^2
HOT
2700 kPa-g / HV
130 C / 150 C
PLATES: 316L SS / GRAPHITE
FRAME: CS
/
9
P-246121-DJE(0.4)
P-246122-DJE(0.4)
COMPABLOC
RATED DUTY:
SURFACE AREA:
DESIGN PRESS:
DESIGN TEMP:
MATERIAL:
INSULATION TYPE/THK:
TRIM:
TEMA TYPE:
COLD
3500 kPa-g / HV
120 C / 150 C
/
HOLDS:
INSTRUMENT SIZING TO BE CONFIRMED DURING DETAILED ENGINEERING.
FC SIGNAL
246.003
12225
TO FFX-001A
TI
004
PI
003
PT
003
3/4" 3/4"
TT
004
1-1/2"
ET 10
63
16"-P-246051-DAB
LEAN AMINE
246.008
12181
TO E-24604A
H
ET 10
38
S-9
3
ET 10
38
PI
028
2"-P-246105-DJE(0.4)
2"
D
2"-P-246106-DJE(0.4)
13145
DAB DJE(0.4)
2"
DJE(0.4) DAB
RS
20"
3"
V 2"
TI
002
2"
ET 10
63
246.033
DM
12227
2"-DM-246001-DAB
DO NOT POCKET
RS
E-24602B
2"
CSO
3"
14"-P-246007-DJE(0.4)
RICH AMINE
246.002
12212
TO V-24601
PI
004
06/13/11
04/20/11
03/01/11
01/10/11
12/02/10
REV
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
ET 10
50
20"
PT
004
TI
005
TT
005
002
2"
D
ET 10
63
1-1/2"
20"
2"
TT
002
ET 10
63
RS
RS
20"
2"
12230
10"-P-246006-DJE(0.4)
8
2"
246.007
NC
3/4"
START-UP
PT
002
3/4" 3/4"
14"x10"
10"
13144
2"-DM-246004-DAB
246.033
DM
2"-DM-246002-DAB
246.033
DM
LEAN AMINE
FROM P-24601A/B/C
8"
D
2"
2"
CSO
16"-P-246048-DJE(0.4)
1-1/2"
16"-P-246054-DAB
LEAN AMINE
SHELL CANADA
246.009
12252
TO E-24604B
A
R
8"-P-246085-DAE
START-UP / MINIMUM FLOW
LEAN AMINE
246.011
FROM P-24602A/B/C
12281
246.0000.000.041.001
REV.
246.001
ET 10
50
2"
3"
ET 10
63
1-1/2"
3/4" 3/4"
PI
002
12"-P-246050-DJE(0.4)
2"
TT
003
CSO
10"
CSO
3"
3/4"
FROM V-44118
ET 10
50
10
10"-P-246002-DJE(0.4)
13143
DJE(0.4) DAB
10"-P-246004-DJE(0.4)
7
246.101
1-1/2"
246.033
DM
2"-DM-246003-DAB
14"x10"
2"
12686
ET 10
63
RICH AMINE
14"-P-246001-DJE(0.4)
2"
20"
12"
14"x10"
14"x10"
DAE DJE(0.4)
242.021
ET 10
50
MIN
12634
10"-P-242064-DJE(0.4)
MIN
RICH AMINE
242 246
E-24602A
2"
10"
3"
10"
TT
001
FT
001
PT
001
3/4" 3/4"
PI
001
2"
14"x10"
TI
001
3/4" 3/4"
FC
001
10"-P-246003-DJE(0.4)
20"
3"
ET 10
50
3/4" 3/4"
RS
16"x12"
RS
PT
028
12"-P-246049-DJE(0.4)
16"x12"
20"
V
2"
20"
RS
12"
RS
8
2"
CSO
ET 10
63
TI
003
10"-P-246005-DJE(0.4)
DAB DJE(0.4)
2"
8"
SP
001
3/4" 3/4"
PDI
002
PI
013
PT
013
PJB(0.4)
DJB(0.4)
CSO
14"x10"
14"x8"
PDI
013
3/4"-KP-246001-PJE(0.4)
246.014
12283
TT
013
1-1/2"
FREE DRAINING
MIN
OVERHEAD VAPOURS
246.005
12275
TO E-24601A/B
FC
003
8"
ANTI-FOAM
TO FFX-001B
42"-P-246015-PJB(0.4)
42"
246.003
12211
10"-P-246100-DJB(0.4)
TC SIGNAL
TC
013
RV
005A
3/4"
CSO
CSO
10"-P-246107-DJB(0.4)
3/4"
3/4"
BLOCKED
DISCHARGE
8T10
SET@
375 kPa-g
12"x10"
8"-P-246100-DJB(0.4)
N/A
ET 10
SIZE:
DESIGN PR. & TEMP:
MATERIAL(VESSEL/INTERNALS):
INSULATION TYPE/THK:
TRIM:
10"x8"
12"x10"
RV
005B
12"-VA-246001-PJB(0.4)
PJB(0.4)
DJB(0.4)
PJB(0.4)
DJB(0.4)
N/A
ET 10
BLOCKED
DISCHARGE
8T10
SET@
375 kPa-g
10"x8"
RV
005C
8"x6"
N/A
ET 10
BLOCKED
DISCHARGE
6Q8
SET@
385 kPa-g
V-24601
AMINE STRIPPER
TO ATMOSPHERE
AT SAFE LOCATION
12"-VA-246002-PJB(0.4)
TO ATMOSPHERE
AT SAFE LOCATION
8"-VA-246003-PJB(0.4)
TO ATMOSPHERE
AT SAFE LOCATION
TO ATM
TO ATM
TO ATM
FROM P-24606
FREE DRAINING
3/4"
REBOILER FEED
12213
FL(C)
3/4"
D
30"-P-246029-DJB(0.4)
TO E-24603A
20"-P-246012-DJE(0.4)
3/4" 3/4"
H
75
15
20"x10"
DJE(0.4)
DJB(0.4)
DAB
10"
14"x10"
4"-P-246026-PJB(0.4)
WATER REFLUX
246.006
12282
SP
FROM P-24603A/B
002
14
TI
010
TT
010
FLOW
20"
10
10
36"
MW
36"
20"-P-246013-DJB(0.4)
10
TI
011
TT
011
2"
DAB
PDI
012
24"
MW
2"-DM-246045-DAB
FREE DRAINING
24"x20"
20
9
DJB(0.4)
36"x24"
HOLDS:
36"x24"
36"
24"x20"
20"-P-246011-DJB(0.4)
2"
DJB(0.4)
2"
DJE(0.4)
15
PV
010B
D
4"x3"
3/4"
MIN
DJB(0.4)
DJE(0.4)
DJB(0.4)
DJE(0.4) PJE(0.4)
CSO
FREE DRAINING
14"-P-246007-DJE(0.4)
TWO PHASE FLOW
12 DO NOT POCKET
FROM E-24602A/B
3/4"
ET 10
63
FO
MIN
4"x3"
4"x2"
2"
2"
7
8
14
24
4"x2"
DETAIL "A"
INJECTION QUILL
20"
FL(C)
3/4"
D
14"x10"
4"x3"
246.001
3/4"
MP-001
20"x10"
PT
010
4"
21
20"-P-246010-DJE(0.4)
24"
MW
PT
011
2"
8
PV
010A
ET 10
38
FREE DRAINING
PHS
010
13
CSC
4"-P-246008-DJE(0.4)
RICH AMINE
PC
010
CSO
PI
011
4"-P-246009-DJB(0.4)
B 3/4"
246.003
DJB(0.4) PJB(0.4)
RV
001
12212
14"
14"-P-246100-DJB(0.4)
FT
003
FV
003
3/4"
BLOCKED DISCHARGE
3L4
SET@
3500 kPa-g
30"
30"
H
75
30"-P-246035-DJB(0.4)
FREE DRAINING
REBOILER FEED
246.004
12210
TO E-24603B
PI
012
FREE DRAINING
2"
LT
002
LL
V
HHLL=7590 mm
HLL=6175 mm
12695
242.021
TO FC-242075
f(x)
1"-SCL-246010-SAB
11
24"
3"
SWING
ELBOW
24"
SET POINT
LX
001
H
50
241.021
12206
TO FC-241075
24"-P-246083-DJB(0.4)
FREE DRAINING
LLL=2175 mm
246.004
4"
04/20/11
03/01/11
01/10/11
12/02/10
REV
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
FROM E-24603B
ET 10
38
LLLL=475 mm
4"-P-246093-DAB
AMINE INVENTORY/MAKE-UP
246.012
SHELL CANADA
D
DJB(0.4)
DAB
ET 10
38
30"
3/4"
12696
FROM P-24605/24604
2"
30"x24"
TT
014
1-1/2"
TI
014
24"-P-246041-DJB(0.4)
LEAN AMINE
12182
246.007
TO P-24601A/B/C
DJB(0.4)
DAB
2"-DM-246005-DAB
6"
ET 10
50
6"-DM-246005-DAB
AMINE DRAIN
13125
TO V-24606
06/13/11
12207
MIN.
2"
SO
LC
001
LT
001
SPLIT
3/4"
N/A
ET 10
LG
001
MIN.
3/4"
12694
NLL=4175 mm
2"
3"
3"-SL-246004-SAB
2"
2"
DJB(0.4)
DAB
246.029
SCL
DAB
24"
FREE DRAINING
246.029
SL
TO FC-441075
12403
MW
FROM E-24603A
441.029
12405
12697
SET POINT
MAG
NNF
24"-P-246082-DJB(0.4)
SET POINT
246.030
GI
2"
3/4"
246.003
ET 10
38
2"-P-246098-DAB
2"
6"
12215
2"
DJB(0.4)
2"
8600 mm
FROM V-24605
3/4"
FROM E-24603B
GWR
3/4"
246.013
2"-GI-246003-ULB
START-UP
12288
2"
1"-SL-246XXX-SAB
12401
V-24601
3/4"
RECOVERED AMINE
2"
PP
LL
246.004
246.007
SCALE: NONE
SHELL DWG NO.:
246.0000.000.041.002
REV.
I
001
FREE DRAINING
246.002
LI
002
2"x3/4"
2"
36"-P-246040-DJB(0.4)
3/4" 3/4"
I
002
HH
H
50
SWING
ELBOW
3/4"
3/4"
I
020
3/4"
PT
012
3/4"
FROM E-24603A
36"
36"
246.003
36"-P-246034-DJB(0.4)
3/4"
12214
H
50
2"x3/4"
E-24603A
STRIPPER REBOILER
V-24603A
STRIPPER REBOILER CONDENSATE POT
RATED DUTY:
SURFACE AREA:
TEMA TYPE:
DESIGN PRESS:
DESIGN TEMP:
MATERIAL:
INSULATION TYPE/THK:
TRIM:
TUBE
500 kPa-g / FV
250 C / 250 C
316L SS + 0.6 mm CA
NONE /
FFX
001A
246.001
FROM FC-001
FFX
001B
FC
005
TC SIGNAL
246.002
246.004
12234
TO FC-006
SPLIT
SP
251
PI
002 C
FROM TC-013
HOLDS:
L
LL
251.110
FROM PX-251022
LL
REBOILER FEED
12213
246.002
H
75
30"-P-246029-DJB(0.4)
PC
014
FREE DRAINING
FROM V-24601
FX
005
10
CB
101 A
CB
101 B
CB
101 C
I
020
CUTBACK SIGNAL
SP LIMIT
36"-P-246034-DJB(0.4)
FREE DRAINING
TO V-24601
FV
005
3/4"
24"x20"
24"-SL-246009-SAB
1-1/2"
10"
30"
2"
E-24603A
24"
N/A
ET 10
B
4"x2"
RV
010
24"
24"-P-246031-DJB(0.4)
24"-P-246030-DJB(0.4)
5
30"x24"
12215
N/A
ET 10
1/2" WEEP HOLE
PP
10"
HLL=4200 mm
ET 10
N/A
2"
FREE DRAINING
24"
MW
MAG
V-24603A
LG
005
2920 mm
FREE DRAINING
LT
005
LC
005
LX
005
NLL=1020 mm
LC SIGNAL
H
24"-P-246082-DJB(0.4)
FREE DRAINING
TO V-24601
13139
2"
LLL=250 mm
10"-SCL-246001-SAB
246.020
TO LV-005
10"
4
8"
06/13/11
04/20/11
03/01/11
01/10/11
12/02/10
REV
ET 10
50
8"-SCL-246002-SAB
TWO PHASE FLOW
3/4"
2"
246.002
4"-VA-246005-SAB
4"
2"-P-246108-DJB(0.4)
246.029
SCL
1"-SCL-246003-SAB
2"
ET 10
N/A
2"
2"
30"x24"
10"
RS
24"
2"
2"
4"x3"
3/4"
3"-SL-246005-SAB
12685
12228
3"x2"
30"
246.029
3/4"
24" MW
TO ATMOSPHERE AT
SAFE LOCATION
FIRE
2J3
SET@
500 kPa-g
LP STEAM
24"-SL-246009-SAB
CSO
TO ATM
DO NOT POCKET
30"-P-246033-DJB(0.4)
36"x30"
2"-SL-246010-SAB
30"-P-246032-DJB(0.4)
24"
N/A
ET 10
2"
36"x30"
FE
005
FROM DISTRIBUTION
D
RS
TT
015
H
50
24"x20"
20"
FC
2"
TI
015
FT
005
1"-SL-246009-SAB
12214
246.004
13128
TO FX-006
3/4"
246.002
PT
014
H
50
3/4"
I
021
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
CONDENSATE
12454
246.020
TO E-24606
SHELL CANADA
QUEST CCS PROJECT
A
R
246.0000.000.041.003
REV.
12211
FFX
001C
TRIM
RATIO
246.003
12225
SIZE:
DESIGN PR. & TEMP:
MATERIAL(VESSEL/INTERNALS):
INSULATION TYPE/THK:
TRIM:
FFIC
001
FC SIGNAL
E-24603B
STRIPPER REBOILER
RATED DUTY:
SURFACE AREA:
TEMA TYPE:
DESIGN PRESS:
DESIGN TEMP:
MATERIAL:
INSULATION TYPE/THK:
TRIM:
V-24603B
STRIPPER REBOILER CONDENSATE POT
TUBE
500 kPa-g / FV
250 C / 250 C
316L SS + 0.6 mm CA
NONE /
SP
246.003
FC
006
FROM FFX-001C
REBOILER FEED
12210
246.002
H
75
30"-P-246035-DJB(0.4)
HOLDS:
FREE DRAINING
FROM V-24601
9
REBOILER VAPOUR RETURN
246.002
12288
H
50
36"-P-246040-DJB(0.4)
PC
016
FREE DRAINING
TO V-24601
FX
006
I
020
10
SP LIMIT
24"x20"
24"-SL-246002-SAB
24" MW
FC
E-24603B
24"
N/A
ET 10
3
FIRE
2J3
SET@
500 kPa-g
N/A
ET 10
TO ATMOSPHERE AT
SAFE LOCATION
246.029
12665
1"-SCL-246006-SAB
246.029
SCL
12400
4"x3"
N/A
ET 10
4"-VA-246006-SAB
3"x2"
LP STEAM
3/4"
CSO
24"-P-246037-DJB(0.4)
30"x24"
3"-SL-246004-SAB
FREE DRAINING
2"
ET 10
N/A
2"
ET 10
N/A
2"
30"x24"
3/4"
4
24"-P-246036-DJB(0.4)
10"
2"
24"
4"x2"
24"
RS
2"
24"-SL-246002-SAB
RV
011
PP
24"
3/4"
2" V
FE
006
FROM DISTRIBUTION
2"
10"
30"
H
50
DO NOT POCKET
30"
24"x20"
20"
1"-SL-246002-SAB
30"-P-246039-DJB(0.4)
36"x30"
2"-SL-246003-SAB
30"-P-246038-DJB(0.4)
3/4"
36"x30"
FV
006
3/4"
FT
006
3/4"
1-1/2"
13128
FROM CB-101A/B/C
RS
TT
016
246.003
PT
016
2"
TI
016
CUTBACK SIGNAL
2"-P-246109-DJB(0.4)
2"
V
FREE DRAINING
4"
HLL=4200 mm
04/20/11
V-24603B
03/01/11
01/10/11
12/02/10
LG
006
NLL=1020 mm
24"
MW
10"-SCL-246004-SAB
LT
006
LC
006
LX
006
B
REV
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
LLL=250 mm
10"
LC SIGNAL
2"
13140
FREE DRAINING
246.020
TO LV-0006
4
8"
D
ET 10
50
8"-SCL-246005-SAB
TWO PHASE FLOW
CONDENSATE
12680
246.020
SHELL CANADA
TO E-24606
A
R
SCALE: NONE
SHELL DWG NO.:
246.0000.000.041.004
REV.
246.004
TO V-24601
06/13/11
3/4"
12207
2"
246.002
H
50
24"-P-246083-DJB(0.4)
2920 mm
10"
E-24601A
STRIPPER OVERHEAD CONDENSER
RATED DUTY:
SURFACE AREA:
TEMA TYPE:
DESIGN PRESS:
DESIGN TEMP:
MATERIAL:
INSULATION TYPE/THIK:
HEAT TRACE MEDIA/TEMP:
TRIM:
26.60 MW (TOTAL)
2272.0 m^2
BHU
SHELL
385.00 kPa-g /FV
150 C/150 C
CS + 3 mm 304L SS CLAD
PP/
TUBE
1100.00 kPa-g/
58 C/
DUPLEX 2205 + 0.38 mm CA
NONE/
P-246127-PJB(0.4)
P-246128-PJB(0.4)
CWR-246030-UAB
CWR-246031-UAB
TW
018
V
2"
N/A ET 10
30"-P-246016-PJB(0.4)
10"-CWR-246011-UAB
1-1/2"
10"-CWR-246011-UAB
FREE DRAINING
12274
CSO
14"x10"
CSO
2"
TW
017
1-1/2"
14"x10"
10"-CWR-246012-UAB
FREE DRAINING
28"
28"
14"
TT
019
6" BACK
FLUSH
42"x30"
2"
RS
30"x28"
1-1/2"
FREE DRAINING
42"x30"
E-24601B
14"
RS
30"x28"
30"x28"
OVERHEAD VAPOUR/LIQUID
12246
246.006
TO V-24602
ET 10
12"-CWS-246029-UAB
246.025
CWS
13146
10"-CWS-246030-UAB
N/A ET 10
14"x10"
10"-CWS-246030-UAB
246.025
CWS
12271
6"
30"-P-246019-PJB(0.4)
FREE DRAINING
42"-P-246020-PJB(0.4)
TWO PHASE FLOW
N/A
2"
28"
28"
PP
BACK
FLUSH
G
06/13/11
04/20/11
03/01/11
01/10/11
12/02/10
B
REV
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
SHELL CANADA
QUEST CCS PROJECT
A
R
SCALE: NONE
SHELL DWG NO.:
246.0000.000.041.005
REV.
246.005
30"-P-246017-PJB(0.4)
TI
019
3/4"
30"-P-246018-PJB(0.4)
FREE DRAINING
NC
4"
14"x12" 12"-CWS-246029-UAB
30"x28"
ET 10
D
4"
30"x28"
42"x30"
30"x28"
4"-CWS-246028-UAB
FREE DRAINING
FROM V-24601
14"
2"
42"-P-246015-PJB(0.4)
28"
RS
246.002
28"
3
12275
42"x30"
OVERHEAD VAPOURS
ET 10
38
E-24601A
NC
14"
4"-CWR-246014-UAB
28"
246.025
CWR
13147
N/A ET 10
28"
10"-CWR-246012-UAB
2"
30"x28"
RS
30"x28"
246.025
CWR
V-24602
STRIPPER REFLUX DRUM
SIZE:
DESIGN PR. & TEMP:
MATERIAL(VESSEL/INTERNALS):
INSULATION TYPE/THK:
TRIM:
36"-GC-246001-PJB(0.4)
FREE DRAINIING
36"
FREE DRAINIING
TO ATMOSPHERE
AT SAFE LOCATION
N/A
ET 10
2"-P-247004-PJB(0.4)
TWO PHASE FLOW
4"x3"
4"
4"-VA-246004-PJB(0.4)
ET 10
38
10"
CSO
ET 10
38
247.002
12244
FROM V-24702
PURGE WATER
241.023
12636
C
2"x1" 2"-SC-246020-SAB
NNF
WATER MAKE-UP
246.021
12131
FROM E-24607
SO
2"x1"
2"-P-246027-PJB(0.4)
2"x1"
1"
MINIMUM FLOW
FO
6"
FI
009
FT
009
PI
015
FC
007
PT
015
3"x1-1/2"
ET 10
38
3"x2"
FT
007
3"x1-1/2"
1-1/2"
FC
WASTE WATER
ET 10
3"-P-246028-PJB(0.4)
38
12653
246.027
TO WWTP 271
SP
003
S-8
3/4"
ET 10
50
4"
6"-P-246021-PJB(0.4)
3"x2"
LV
010
3/4" 3/4"
3/4"
2"
FV
007
3/4"
3/4"
KO LIQUIDS
3/4" 3/4"
LLLL=300 mm
FROM V-24704
LC
010A
2"
LLL=400 mm
2"
LT
010
FC
3/4"
2"
LG
010
LC
010B
2"x1" 2"x1"
1"
3/4"
MAG
NLL=675 mm
13032
FT
008
FV
008
2"x1"
ET 10
38
247.004
FC
008
SAB
HLL=3075 mm
3"-P-241076-PJE(0.4)
PJB(0.4)
H
24"
MW
K.O. LIQUID
2"
MIN
2"
4"x3"
4"x3"
ET 10
38
4"-P-246026-PJB(0.4)
WATER REFLUX
12282
246.002
TO V-24601
SEL
ET 10
38
3/4"
3/4"
HS
008A
3/4"
R/S
HIS
008
I
003
2"
3/4"
2"
MIN
MIN
HOA
D
D
P-24603A
PJB(0.4)
DAB
3/4"-DM-246007-DAB
ET 10
38
D
D
04/20/11
03/01/11
01/10/11
12/02/10
ISSUED
DATE
DESCRIPTION
3/4"
P-24603B
3/4
"
PJB(0.4)
DAB
3/4"-DM-246009-DAB
ET 10
38
3/4"
CS
MC
PDP
APE
PEM CLIENT
APP
A
2"-DM-246011-DAB
246.033
DM
12391
3/4"
P-24603A/B 8
STRIPPER REFLUX PUMPS
MATERIAL:
INSULATION TYPE/THK:
TRIM:
PRS
3/4"
D
50.3 m^3/hr
559 kPa
15.0 kW
CASING
316 SS
/
CKD
SHELL CANADA
ET 10
38
RATED FLOW:
DIFF. PR.:
DRIVER:
BY
4"-P-246025-PJB(0.4)
3/4"
3/4
"
PP
3/4"
3/4"
3/4"
3/4"
4"-P-246024-PJB(0.4)
REV
PP
SP
004B
ET 10
38
3/4"
PP
06/13/11
4"
4"
PP
SP
004A
PJB(0.4) DAB
3/4"
PJB(0.4) DAB
INTERNALS
316 SS
7
246.0000.000.041.006
REV.
HIS
007
I
003
R/S
2"-DM-246010-DAB
HS
007A
HOA
246.006
HS
109
6"-P-246022-PJB(0.4)
LI
011
ET 10
38
MIN
3/4"
2"
3/4"
4800 mm
LL
FROM V-24703
FROM E-24129/24229
V-24602
LT
011
13033
3"
PP
GWR
247.003
PJE(0.4)
MIN
42"
3"-P-241113-PJB(0.4)
I
003
PJB(0.4)
FREE DRAINING
3"
FREE DRAINING
6"-P-246023-PJB(0.4)
FROM E-24601A/B
2"-P-247002-PJB(0.4)
K.O. LIQUID
3/4"
2"-DM-246008-DAB
246.005
3"x2"
4"-P-246074-PJB(0.4)
12246
3/4"
42"-P-246020-PJB(0.4)
TWO PHASE FLOW
247.001
12368
HOLDS:
RV
013
CO2
TO V-24701
2"-P-247003-PJB(0.4)
BLOWTHROUGH
3K4
SET@
385 kPa-g
OVERHEAD VAPOUR/LIQUID
HOLDS:
INSTRUMENT SIZING TO BE CONFIRMED DURING DETAILED ENGINEERING.
FI
010
FT
010
LEAN AMINE
246.002
12182
14"
ET 10
75
24"-P-246041-DJB(0.4)
16"x14"
FROM V-24601
ET 10
63
16"-P-246048-DJE(0.4)
16"x14"
LEAN AMINE
246.001
12230
TO E-24602A/B
12"-P-246048-DJE(0.4)
C
ET 10
63
DJB(0.4)
DJE(0.4)
P-24601A
I
001
DAB
R/S
HIS
001
13130
12"-P-246047-DJE(0.4)
7
I
001
R/S
HS HOA
001A
HIS
002
DAB
3/4" 3/4"
2"
DAB
DJE(0.4)
DAB
LOCAL/
REMOTE
VFD
FAULT
16"x12"
DJE(0.4)
SI
003
"
3/4
2"-DM-246023-DAB
ET 10
63
2"-DM-246019-DAB
I
002
3/4" 3/4"
SP
005C
DJE(0.4)
MIN
MIN
VFD
P-24601B
XL
003
XA
003
VFD
I
002
P-24601C
I
001
R/S
HS HOA
002A
3/4"-DM-246018-DAB
3/4"-DM-246014-DAB
246.013
12"x8"
16"x12"
"
3/4
1"
1"
DJE(0.4)
VFD
FAULT
PP
HIS
003
06/13/11
04/20/11
03/01/11
01/10/11
12/02/10
HS HOA
003A
REV
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
3/4"-DM-246022-DAB
6"-DM-246006-DAB
TO V-24606
AMINE DRAIN
13125
246.002
SEL
SHELL CANADA
6"-DM-246005-DAB
FROM V-24601
246.011
4
MATERIAL:
INSULATION TYPE/THK:
TRIM:
755.3 m^3/hr
909 kPa
261.0 kW (EACH)
CASING
INTERNALS
316 SS
316 SS
H/
6
P-246132-DJE(0.4)
P-246133-DJE(0.4)
P-246134-DJE(0.4)
FROM PC-041
P-24601A /B /C
LEAN AMINE PUMPS
RATED FLOW:
DIFF. PR.:
DRIVER:
12904
246.0000.000.041.007
REV.
246.007
HS
104
DAB
LOCAL/
REMOTE
2"-DM-246021-DAB
XL
002
3/4"-DM-246020-DAB 3/4"
SI
002
XA
002
AMINE DRAIN
16"-P-246044-DJE(0.4)
MIN
MIN
VFD
DAB
DJE(0.4)
3/4" 3/4"
2"
DJE(0.4)
I
002
3/4" 3/4"
ET 10
63
VFD
FAULT
SP
005B
2"-DM-246017-DAB
DAB
"
3/4
LOCAL/
REMOTE
12"x8"
16"x12"
DJE(0.4)
2"
PP
PP
3/4"-DM-246016-DAB 3/4"
XL
001
XA
001
2"
2"-DM-246013-DAB
3/4"-DM-246012-DAB 3/4"
DJE(0.4)
DAB
PP
SI
001
2"-DM-246015-DAB
3/4" 3/4"
3/4" 3/4"
DJE(0.4)
DAB
2"
MIN
MIN
1"
ET 10
63
PP
SP
005A
DJE(0.4)
DAB
16"-P-246043-DJE(0.4)
DAB
DJE(0.4)
12"-P-246046-DJE(0.4)
ET 10
50
12"-P-246045-DJE(0.4)
16"-P-246042-DJE(0.4)
2"
PP
2"
DJE(0.4)
DAB
12"x8"
2"
ET 10
50
ET 10
50
MIN
2"
MIN
DJB(0.4)
DJE(0.4)
MIN
DJB(0.4)
DJE(0.4)
E-24604A
LEAN AMINE COOLER
RATED DUTY:
SURFACE AREA:
TEMA TYPE:
DESIGN PRESS:
DESIGN TEMP:
MATERIAL:
INSULATION TYPE/THK:
TRIM:
E-24605A
LEAN AMINE TRIM COOLER
20.8 MW
829.0 m^2
BEU
SHELL
1500 kPa-g / HV
130 C / 150 C
CS + 3mm 304L SS CLAD
/
5
P-246135-DAB
RATED DUTY:
SURFACE AREA:
TUBE
1155 kPa-g /
58 C /
DUPLEX 2205 + 0.38 mm CA
/
CWR-246032-UAB
DESIGN PRESS:
DESIGN TEMP:
MATERIAL:
INSULATION TYPE/THK:
TRIM:
TEMA TYPE:
FIRE
1-1/2G3
SET@
1500 kPa-g
COLD
1155 kPa-g /
58 C /
/
V
3"-DM-246062-DAB
TW
029
DM
246.033
CSO
1-1/2"
3/4"
12"
ET 10
N/A
ET 10
38
N/A
ET 10
3"x1-1/2"
3/4"
RV
002
15.5 MW
676.0 m^2
HOT
1500 kPa-g / HV
105 C / 150 C
PLATES: 316L SS / GRAPHITE
FRAME: CS
/
5
P-246136-DAB
PLATE & FRAME
HOLDS:
2"
246.025
CWR
12"-CWR-246001-UAB
ET 10
38
ET 10
63
FROM E-24602A/B
16"
2"
16"
16"
2"
D
RS
16"
4"-CWS-246019-UAB
4"
E-24604A
C
16"x12"
MIN.
16"-P-246057-DAB
BACK FLUSH
246.025
CWS
12"-CWS-246018-UAB
12958
ET 10
N/A
N/A
ET 10
6"
12"
16"-P-246105-DAB
LEAN AMINE
246.009
12949
FROM E-24605B
ET 10
63
16"-P-246051-DAB
4"-CWR-246002-UAB
TI
026
PP
TC
027
1-1/2"
RS
2"
2"
RS
RS
RS
2"
TT
026
ET 10
63
24"x16"
1-1/2"
2"
1-1/2"
24"-P-246059-DAB
LEAN AMINE
246.010
12253
TO FILTRATION/P-24602A/B/C
3
D
2"-DM-246063-DAB
ET 10
50
E-24605A
TT
027
24"x16"
ET 10
63
2"
3/4" 3/4"
TW
025
ET 10
50
3/4"
TW
028
12"-P-246104-DAB
12"x8"
8"-P-246052-DAB
3
12"x8"
6"
4"-CWR-246007-UAB
4"
10"-CWR-246006-UAB
NC
246.009
04/20/11
03/01/11
01/10/11
12/02/10
B
REV
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
12251
FROM E-24604B
ET 10
ET 10
N/A
4"-CWS-246024-UAB
SHELL CANADA
10"-CWS-246023-UAB
ET 10
38
ET 10
N/A
BACK FLUSH
ET 10
50
LEAN AMINE
06/13/11
N/A
10"
MIN.
N/A
ET 10
CSO
MIN.
2"
8"-P-246055-DAB
12960
246.0000.000.041.008
REV.
246.008
246.025
CWS
12959
246.025
CWR
8"
TV
027
12"x8"FC12"x8"
12596
246.033
DM
1-1/2"
10"
246.001
RS
12181
CSO
MIN.
NC
LEAN AMINE
CSO
3"-P-246053-DAB
16"x12"
12957
2
E-24605B
LEAN AMINE TRIM COOLER
E-24604B
LEAN AMINE COOLER
RATED DUTY:
SURFACE AREA:
TEMA TYPE:
DESIGN PRESS:
DESIGN TEMP:
MATERIAL:
INSULATION TYPE/THK:
TRIM:
RATED DUTY:
SURFACE AREA:
20.8 MW
829.0 m^2
BEU
SHELL
1500 kPa-g / HV
130 C / 150 C
CS + 3 mm 304L SS CLAD
/
4
P-246137-DAB
12251
3"-DM-246064-DAB
DM
246.033
1-1/2"
12"
CSO
3/4"
CWR
13026
16"
2"
16"
16"
4"-CWS-246021-UAB
4"
E-24604B
16"-P-246058-DAB
RS
16"
NC
2"
4"-CWR-246004-UAB
FROM E-24602A/B
ET 10
38
16"x12"
ET 10
63
RS
N/A
ET 10
16"x12"
MIN.
12"
12"-CWS-246020-UAB
CWS
6"
13027
BACK
FLUSH
PP
2"
2"
RS
RS
2"
2"
E-24605B
1-1/2"
ET 10
63
RS
3
16"-P-246110-DAB
LEAN AMINE
12949
246.008
TO FILTRATION /
P-24602A/B/C
TW
038
2"-DM-246065-DAB
CSO
MIN.
04/20/11
03/01/11
01/10/11
12/02/10
REV
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
APE
PEM CLIENT
APP
12262
246.033
DM
4"-CWS-246026-UAB
MIN.
10"
R
6"
N/A
ET 10
N/A
BACK
FLUSH
MC
PDP
13029
CS
SHELL CANADA
10"-CWS-246025-UAB
CWS
ET 10
38
4"
4"-CWR-246009-UAB
13028
06/13/11
246.0000.000.041.009
REV.
246.009
CWR
ET 10
38
10"-CWR-246008-UAB
ET 10 N/A
10"
2"
N/A
RS
ET 10
63
1-1/2"
2"
3/4" 3/4"
TW
035
NC
16"-P-246054-DAB
CSO
3
246.001
MIN.
3"-P-246056-DAB
12252
12"-CWR-246003-UAB
CSO
TO BYPASS
LEAN AMINE
HOLDS:
ET 10
N/A
ET 10
38
2"
3/4"
3"x1-1/2"
ET 10
50
ET 10
N/A
246.008
8"-P-246055-DAB
COLD
1155 kPa-g /
58 C /
TW
039
RV
003
INSULATION TYPE/THK:
TRIM:
TEMA TYPE:
15.5 MW
676.0 m^2
HOT
1500 kPa-g / HV
105 C / 150 C
PLATES: 316L SS / GRAPHITE
FRAME: CS
4
/
P-246138-DAB
PLATE & FRAME
FIRE
1-1/2G3
SET@
1500 kPa-g
LEAN AMINE
DESIGN PRESS:
DESIGN TEMP:
MATERIAL:
TUBE
1155 kPa-g /
58 C /
DUPLEX 2205 + 0.38 mm CA
/
CWR-246034-UAB
N/A
ET 10
V-24604
LEAN AMINE FILTER
246.012
12140
FROM P-24604
SIZE:
RATED FLOW:
DESIGN PR. &TEMP:
PRESSURE DROP (CLEAN/DIRTY):
MATERIAL:
INSULATION TYPE/THK:
TRIM:
SIZE:
RATED FLOW:
DESIGN PR. &TEMP:
PRESSURE DROP (CLEAN/DIRTY):
MATERIAL:
INSULATION TYPE/THK:
TRIM:
PARTICLE RETENTION SIZE:
4"-P-246088-DAB
START-UP
NC
FX
015
FV
015
MIN
246.008
3/4"
FROM E-24605A/B
24"-P-246059-DAB
16"
SP
006
6"-P-246XXX-DAB
PP
6"x4"
S8
ET 10
50
2"-P-246084-DAB
246.012
2"-DM-246030-DAB
246.033
DM
10"x6"
3/4"
246.033
DM
ET 10
3"-DM-246027-DAB 38
CSO
3/4"
1"
2"-P-246069-DAB
D
CSC
3/4" 3/4"
ET 10
38
RS
3"
4"
3/4"
MIN
13142
ET 10
50
13135
6"-P-246068-DAB
PP
3/4" 3/4"
RV
021
3/4"
10"-P-246066-DAB
6"x4"
246.011
3/4" 3/4"
FT
016
H
3/4" 3/4"
3"
2"
PDC
035
FIRE
1-1/2H3
SET@
1500 kPa-g
3/4"
SP
007
4
PDT
035
10"-P-246066-DAB
FX
016
CSO
13134
CSC
1"
CSO
FC
016
3/4" 3/4"
38
ET 10
ET 10
50
10"x8"
2"x1-1/2"
3/4"
3/4"
2"-DM-246025-DAB
FO
8"
246.033
DM
PP
10"-P-246063-DAB
2"x1"
2"-GI-246013-ULB
246.030
GI
3/4"
3/4"
V
RS
DAB ET 10
ULB N/A
DAB
SAB
2"-P-246065-DAB
10"x8"
ET 10
50
3/4"
FT
015
10"x8"
ET 10
50
CSO
10"x8"
MIN
MIN
12235
TO TK-24601
SHUT DOWN
FIRE
1D2
SET@
1500 kPa-g
RV
020
6"-P-246075-DAB
FC
FV
016
2"x1"
1"-P-246064-DAB
ET 10
38
FC
015
HZI
040
HZT
040
HV
040
S8
3
TO P-24602A/B/C
3/4"
3/4" 3/4"
3/4"
FO
ET 10
75
24"x16" FO 24"x16"
D
A/S
3/4" 3/4"
12253
16"
ET 10
75
HOLDS:
HYI
040
24"-P-246059-DAB
LEAN AMINE
O/C
HIS
040
ET 10
38
ID x F/T
71 m^3/hr
1500 kPa-g @ 90 C / HV @ 150 C
35 kPa / 103 kPa
CS + 3 mm CA + PWHT / 316L SS INTERNAL
/
5
P-246141-DAB
10 microns ABSOLUTE
13136
START-UP AMINE
ID x F/T
355 m^3/hr
1500 kPa-g @ 90 C / HV @ 150 C
35 kPa / 103 kPa
CS + 3 mm CA + PWHT / 316L SS INTERNAL
/
5
P-246139-DAB
10 microns ABSOLUTE
V-24609
LEAN AMINE POST FILTER
2"
SIZE:
RATED FLOW:
DESIGN PR. &TEMP:
PRESSURE DROP (CLEAN/DIRTY):
MATERIAL:
INSULATION TYPE/THK:
TRIM:
PARTICLE RETENTION SIZE:
V-24608
LEAN AMINE CARBON FILTER
V-24604
V-24608
3"
3/4" 3/4"
2"-SC-246015-SAB
B
PDC
036
PDT
036
PDC
037
SP
008
24"
MW
3/4" 3/4"
3
3"
V
3/4"
PP
PDT
037
S8
12690
246.030
GI
2"-GI-246014-ULB
DAB
SAB
12387
246.033
DM
ET 10
38
ET 10
2"-DM-246024-DAB
38
ET 10 DAB
N/A ULB
06/13/11
04/20/11
03/01/11
01/10/11
12/02/10
3"
2"
REV
6"-P-246072-DAB
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
SP
009
3"
S8
3"
3
246.034
SC
2"-SC-246012-SAB
ULB DAB
N/A ET 10
ET 10
38
ET 10
38
D
DAB
SAB
ET 10
38
12462
12390
2"x1"
2"-DM-246029-DAB
ET 10
38
246.0000.000.041.010
REV.
246.010
2"-SC-246XXX-SAB
MIN
1"-P-246076-DAB
246.033
DM
GI
246.030
2"-GI-246012-ULB
DM
246.033
3/4"
13141
12687
SHELL CANADA
3/4" 3/4"
3"-DM-246026-DAB
MIN
ET 10
38
ET 10
38
V-24609
3/4" 3/4"
3/4"
ET 10
50
3/4"
3/4" 3/4"
6"-P-246070-DAB
MIN
2"-SC-246014-SAB
PP
UC
002
FROM FC-241075
LEAN AMINE FLOW SIGNAL
FC
020
I
002
441.029
FV
020
FROM FC-441075
DAE DAG
8"x6" FO 8"x6"
DM
DAG
DAB
24"-P-246059-DAB
10 . TWO CHECK VALVES IN SERIES, ONE IN THE HORIZONTAL AND ONE IN THE
VERTICAL POSITION, SEPARATED BY AT LEAST 500 mm.
I
002
PT
042
LL
PI
042
FT
020
ET 10
75
ET 10
63
24"x16"
24"-P-246080-DAG
16"-P-246080-DAG
DETAIL "A"
INJECTION QUILL
LEAN AMINE
241.021
12644
TO V-24118/V-24218
ET 10
75
SP
3/4"
12
PC
041
12904
TO P-24601A/B//C
I
001
I
002
13
PJG(0.4)
3/4" 3/4"
PT
041
LL
010
DAG
FLOW
MP-002
LL
24"x16"
13
24"x16"
ET 10
63
14"-P-246081-DAG
246.101
12238
HOLDS:
TO V-44118
DAG
PJG(0.4)
LEAN AMINE
3/4"
MIN.
5
ET 10
38
3/4"-KP-246003-PJG(0.4)
ANTI-FOAM
246.014
12239
FROM P-24606A/B
24"x18"
10
2"
ET 10
63
ET 10
63
16"-P-246077-DAG
PP
P-24602A
I
002
I
001
MIN
MIN
1"
P-24602B
4
HS
005A
HOA
I
002
I
001
3/4"-DM-246037-DAG
D
HIS
005
DAB
R/S
16"x8"
18"x12"
3/4
"
I
D
P-24602C
4
7
HS
006A
HOA
I
002
06/13/11
04/20/11
03/01/11
01/10/11
12/02/10
I
001
REV
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
3/4"-DM-246041-DAG
3/4"
DAG
3/4"
2"
D
3/4"
16"x8"
18"x12"
3/4
"
I
D
3/4"-DM-246033-DAG
HIS
004
PP
HIS
006
R/S
2"
3"x2"
3"-DM-246043-DAB
3/4"
2"-DM-246043-DAB
R/S
3/4"
D
DAB DAG
HOA
3/4" 3/4"
2"-DM-246040-DAG
7
HS
004A
SP
011C
3/4"-P-246039-DAG
D
2"-DM-246036-DAG
3/4"-DM-246035-DAG 3/4"
2"
16"x8"
18"x12"
PP
3/4
"
2"
2"-DM-246032-DAG
3/4"-DM-246031-DAG 3/4"
FO
108
3/4" 3/4"
SP
011B
2"
18"-P-246062-DAG
MIN
1"
MIN
18"-P-246061-DAG
3/4" 3/4"
3/4" 3/4"
3/4" 3/4"
PP
FO
107
PP
ET 10
63
2"-DM-246034-DAG
1"
MIN
MIN
18"-P-246060-DAG
SP
011A
16"-P-246079-DAG
2"
PP
3/4" 3/4"
11
16"-P-246078-DAG
2"
FO
106
2"
ET 10
63
2"
ET 10
63
11
MIN
MIN
11
DAB
DAG
11
ET 10
63
DAB
DAG
MIN
11
2"-DM-246038-DAG
DAB
DAG
11
10
HS
107
SHELL CANADA
SEL
A
ISSUED FOR HAZOP
P-24602A /B /C
LEAN AMINE CHARGE PUMPS
4
RATED FLOW:
DIFF. PR.:
DRIVER:
MATERIAL:
INSULATION TYPE/THK:
TRIM:
246.0000.000.041.011
REV.
24"x18"
246.011
246.007
DAB DAG
246.010
12235
8"-P-246XXX-DAG
2"-DM-246042-DAG
ET 10
50
6"
8 . UC-002 SHALL MONITOR LEAN AMINE FLOWS TO EACH HMU PLANT AND THE
TOTAL LEAN AMINE FLOW INCLUDING THE MINIMUM FLOW RECYCLE. UC-002
WILL PROVIDE A SET POINT TO FC-020 BASED ON THE NUMBER OF RUNNING
PUMPS AND WILL AUTOMATICALLY PREVENT EXCESSIVE PUMPING BY STOPPING
ONE OF THE RUNNING PUMPS VIA I-002.
3/4" 3/4"
TO E-24602A/B
ET 10
50
8"-P-246085-DAE
12985
12281
2"
246.001
2"-DM-246057-DAB
LEAN AMINE
3/4"
12983
SP
FROM FC-242075
LEAN AMINE FLOW SIGNAL
PV
242.021
12982
f(x)
PV
241.021
12981
3
TK-24601
AMINE MAKE-UP TANK
SIZE:
WORKING CAPACITY:
DESIGN PR. & TEMP.:
MATERIAL (SHELL/COIL):
INSULATION TYPE/THK:
TRIM:
PC
048A
CSO
?
?
2"x1-1/2"
?
?
?
?
LT
015
2"x1-1/2"
FROM V-24605
5063357
?
TK-24601
?
?
5163612
ET 10
N/A
5156168
MAKE-UP AMINE
1-1/2"
H
25
3/4"
?
?
2"-SCL-246015-SAB
ET 10
38
TK-24602
14
3/4"
D
4" ?
?
NLL=2600 mm
2"
ET 10
38
2"x1-1/2"
ET 10
63
NLL=2600 mm
2"
?
?
FO
N/A ET 10
24"
15
10
ET 10
38
?
?
3"
LT
017
5156893
3"
ET 10
38
ET 10
63
2"
3"
?
38
ET 10
0.75 M
FROM P-24608A/B
2"-SL-246020-SAB
2"x1-1/2"
0.75 M
246.029
SL
H
25
2"
6"
12125
1-1/2"
TV
041
ET 10 N/A
246.021
START-UP
FO
?
?
CONDENSATE
2"x1-1/2"
?
?
10
027
8
2"
LI
017
ET 10
63
FG
NC 5163480
5156168 C-1
C-1
LLL=1500 mm
ET 10
24"-P-246112-DAB
4"-SC-246009-SAB
4"
TT
041
2"
ET 10
63
2"-P-246111-DAB
DAB SAB
MIN
2"
TT
040
4"-P-246092-DAB
HLL=11500 mm
(TYPICAL OF 2)
TC
041
HHLL=12000 mm
24"
MW
?
?
12143
HORN
SILENCE
MIN. 2 m
LLL=1500 mm
2"x1-1/2"
2"
12144
246.029
SCL
HORN
TEST
LI
016
HLL=11500 mm
(TYPICAL OF 2)
TV
040
5115227
?
2"-SL-246009-SAB
LHS
016
HHLL=12000 mm
24"
MW
5115227
?
246.029
SL
TC
040
5156168
?
2"
4"
SP
019
5163612
C-1
?
?
2"-SCL-246007-SAB
ET 10
2"
13167
246.029
SCL
?
?
13168
6" 6"
SP
12
BERM
BERM
ET 10
63
2"-P-246091-DAB
4" 4"
NC 5163612
5156168 C-1
C-1
2"
ET 10
50
3/4"-DM-246047-DAB
3/4
"
INTERMITTENT
?
C-1
TO V-24601
246.023
DM
246.023
DM
13175
13176
2"-DM-246044-DAB
NC
?
C-1
?
?
07/11/11
04/20/11
03/01/11
01/10/11
12/02/10
REV
R/S
PP
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
?
C-2
2"x3"
3"x2"
3/4"
SP
022B
2"-DM-246055-DAB
?
C-1
HIS
010
3/4"-DM-246052-DAB
3/4"-DM-246048-DAB
I
005
PP
2"
5156893
C-1
5063357
C-1
2"-P-246091-DAB
HS
010A
3/4"-DM-246051-DAB
5061864
?
3"-P-246087-DAB
2"-DM-246050-DAB
3/4"
C- ?
1
246.002
ET 10
50
2"
5063357
C-1
ET 10
50
ET 10
50
ET 10
38
HOA
3/4"
4"x3"
3/4"-DM-246049-DAB
?
C-2
PP
ET 10
50
2"-DM-246056-DAB
3/4"
V
5061864
?
3/4"
P-24604
3/4"
ET 10
38
?
C-1
3/4"
D
?
C-1
3/4"
ET 10
38
C-2
3/4
"
P-24605
C- ?
1
SHELL CANADA
3/4"-DM-246054-DAB
2"-DM-246053-DAB
ET 10
50
13174
P-24605
AMINE MAKE-UP PUMP
RATED FLOW:
DIFF. PR.:
DRIVER:
RATED FLOW:
DIFF. PR.:
DRIVER:
60.0 m^3/hr
758 kPa
12.6 kW
CASING
INTERNALS
MATERIAL: 316 SS
316 SS
11
INSULATION TYPE/THK:
/
TRIM: P-246149-DAB
MATERIAL:
INSULATION TYPE/THK:
TRIM:
15.0 m^3/hr
3
300 kPa
1.3 kW
CASING
INTERNALS
316 SS
316 SS
11
/
P-246150-DAB
12620
P-24604
AMINE RE-INVENTORY PUMP
246.033
DM
246.0000.000.041.012
REV.
246.012
246.023
DM
R/S
6"x4"
3/4"-DM-246046-DAB
FO
110
?
C-2
3/4"
SP
022A
NC
?
C-2
NC
5156168
C-1
3/4"
5061864
?
HIS
009
12696
2"-P-246090-DAB
FT
025
4"-P-246088-DAB
PP
5063357 ?
C-1
C-1
?
C-2
2"x1-1/2"
3/4"
FO
C-1
ET 10
38
I
004
FV
025
2"x1-1/2"
2"
1-1/2"
?
C-1
D
FC
025
?
C-1
HOA
TO V-24604
AMINE INVENTORY/MAKE-UP
4"-P-246093-DAB
START-UP
NC
?
C-2
NC
?
C-1
2"-P-246089-DAB
HS
009A
246.010
?
C-1
3/4"
V
5061864
?
12140
6"x3"
5156168
C-1
SP
020
START-UP AMINE
4"-P-246088-DAB
START-UP
5163612
C-1
12
ET 10
50
6"-P-246086-DAB
3/4"
FC
C-1 C-1
4"
12
5156168
C-1
HS
116
HOLDS:
6"
5163612
?
4"
14
XZT
005
ET 10
63
FROM V-24609
SP
021
FO
?
?
6"-P-246075-DAB
246.010
12142
6"
24" MW
XV
005
FO
24" MW
A/S
GWR
N/A
ET 10
6"x4"
GAUGE
HATCH
8"
I
007
006
XYI
005
ET 10
38
6"
LT
016
PVSV
046
13
PV
048B
2"
2"-P-246099-DAB
NNF
246.013
LAH
016A
6"x4"
?
?
LI
016 A
GAUGE
HATCH
8"
6"
6"-P-246071-ULB
?
?
FC
12139
4"
RADAR
13
RECOVERED AMINE
3"
12145
LI
015
PIT
048
PV
048A
TO ATMOSPHERE AT
SAFE LOCATION
?
?
2"-GI-246010-ULB
1-1/2"
3/4"
246.030
GI
HH
I
006
5119160
?
PCV
045
3/4"
2"-GI-246011-ULB 2"
SET@
75 kPa-g
PC
048B
5119160
?
3/4"
3/4"
SIZE:
WORKING CAPACITY:
DESIGN PR. & TEMP.:
MATERIAL (SHELL/COIL):
INSULATION TYPE/THK:
TRIM:
?
?
3/4"
4"x3"
4"-VA-246010-ULB
TK-24602 3
AMINE MAKE-UP TANK
?
C-2
RV
046
6"-VA-246011-ULB
CV FAILURE
2J3
SET@
90 kPa-g
TO ATMOSPHERE
AT SAFE LOCATION
V-24606
AMINE DRAIN DRUM
V-24605
DRAINED AMINE FILTER
SIZE:
RATED FLOW:
DESIGN PR. &TEMP:
PRESSURE DROP (CLEAN/DIRTY):
MATERIAL:
INSULATION TYPE/THK:
TRIM:
PARTICLE RETENTION SIZE:
D
V
TO ATMOSPERE
AT SAFE
LOCATION
3/4"
LHS
021A
FREE DRAINING
TO V-24601
246.034
SC
12463
ET 10
38
RS
3"
3/4"
ET 10
38
2"-P-246094-DAB
S8
4"-P-246101-DAB
SP
013
HORN
SILENCE
36"
MW
2"
3/4"
ET 10
38
I
019
TI
045
LIT
021
TT
045
GWR
2"
I
008
NNF
WASTE WATER
12294
GWR
2"
TO WWTP 271
NC
36"
4"
2"
RS
CSO
6"
6"
RS
4
4"
6"
HHLL=2405 mm
HLL=2255 mm
6"-DM-246060-DAB
AMINE DRAINS
13037
246.033
13
3/4"
ET 10
50
6"-DM-246061-DAB
06/13/11
04/20/11
03/01/11
01/10/11
12/02/10
REV
6"
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
LLL=200 mm
CSO
FREE DRAINING
CSO
FREE DRAINING
V-24606
6"
13
246.033
13036
ET 10
50
3/4"
AMINE DRAINS
246.027
LT
020
2"
2"-WP-246003-DAB
P-24607
S-24601
2"
SHELL CANADA
QUEST CCS PROJECT
A
R
P-24607
AMINE DRAIN PUMP
RATED FLOW:
DIFF. PR.:
DRIVER:
S-24601
AMINE DRAIN DRUM SUMP
MATERIAL:
INSULATION TYPE/THK:
TRIM:
25.0 m^3/hr
641 kPa
7.5 kW
CASING
INTERNALS
316 SS
316 SS
/
12
P-246147-DAB
246.0000.000.041.013
REV.
246.013
246.002
6"
ET 10
50
RS
RS
246.033
12477
12401
13
AMINE DRAINS
1m x 1m
HOLD
3/4"
6"-DM-246006-DAB
3/4"
ET 10
38
2"
11
PP
2"
4"x2"
LI
020
RS
2"-SC-246013-SAB
3"x2"
SP
012B
2"
HH
RS
4"x2"
LI
021
HS
011A
LAH
021A
CSO
SP
012A
LHS
021
I
008
HOA
RS
3/4"
SO
FROM V-24701
2"
247.001
12626
HS
121
R/S
HIS
011
HORN HORN
TEST SILENCE
ET 10
38
2"-DM-247002-PJB(0.4)
NNF
TWO PHASE FLOW
PDI
052
RECOVERED AMINE
2"
SO
ET 10
50
PDT
052
ET 10
38
2"-P-246102-DAB
3/4"
6"-DM-246006-DAB
V-24605
2"-P-246098-DAB
RS
246.007
13130
ET 10
38
RS
AMINE DRAINS
HOLDS:
NC
FC
3/4"
12461
ULB DAB
1" 2"x1"
2"x1"
2"-GI-246007-ULB
TO TK-24601
3/4"
PCV
049
N/A ET 10
246.030
GI
PV
050A
2"-P-246097-DAB
DAB
SAB
FREE DRAINING
PT
050
246.012
2"-P-246096-DAB
2"-DM-246058-DAB
SET@
100 kPa-g
CSC
12139
NNF
3"
NC
8"-VA-246009-DAB
10
RECOVERED AMINE
2"
3"
CSC
4"-P-246103-DAB
CSO
3/4"
FO
3"x1-1/2"
3"
1-1/2"
3"x1-1/2"
4"x3"
PC
050A
PV
050B
FREE DRAINING
PC
050B
VAPOUR BLOWTHROUGH
4M6
SET@
350 kPa-g
6"-VA-246007-DAB
RV
025
2"-P-246099-DAB
2"
2"-P-246095-DAB
2"
3"-VA-246008-DAB
3/4"
CSO
CSO
ET 10
38
2"x1"
2"-DM-246059-DAB
FIRE
1D2
SET@
1050 kPa-g
RV
026
3/4"
ET 10
38
ID x
25 m^3/hr
1050 kPa-g @ 150 C / HV @ 150 C
35 kPa / 150 kPa
CS + 3 mm CA + PWHT / 316 SS INTERNAL
/
12
P-246146-DAB
10 microns ABSOLUTE
3/4"
SIZE:
DESIGN PR. & TEMP:
MATERIAL(VESSEL/INTERNALS):
INSULATION TYPE/THK:
TRIM:
S- 02NULL
ANTI-FOAM INJECTION PACKAGE
HOLDS:
NUMBER OF RVs AND SIZING TO BE CONFIRMED DURING DETAILED ENGINEERING.
INSTRUMENT SIZING TO BE CONFIRMED DURING DETAILED ENGINEERING.
PI
055
S- 02NULL
OUTSIDE
INSIDE
1"-VA-246017-PAB
VENDOR
SP
017
1" HOSE
1" HOSE
SP
016
SET@
3500 kPa-g
3/4" 3/4"
1"
(BY SHELL)
2"x1"
3/4"
FI
111
VENDOR
3/4"
1" HOSE
2"x1"
1-1/2"x1"
LHS
023A
2"
LG
024
LL
LT
023
LG
023
1000 L
TOTE TANK
(OPERATING)
MAG
I
010
2"
HORN
SILENCE
3/4" HOSE
3/4"
3/4"
3/4"
2"
P-24606
ET 10
38
N/A
INSIDE
SS TUBING PJE(0.4)
INSTR. PIPING
ANTI-FOAM
12286
241.021
ET 10
38
ET 10
OUTSIDE
ANTI-FOAM
12283
246.002
TO V-24601
HOA
I
010
D
3/4"
LI
023
3/4"-SS TUBING
TO V-24118/24218
3/4"-KP-246001-PJE(0.4)
HS
015A
3/4"
2"
2"x3/4"
246.011
PIPING SP
014B
SS TUBING PJG(0.4)
INSTR. PIPING SP
015
5
PP
1-1/2"x1"
I
009
LHS
023
2"x1"
4
LAH
023A
12239
PULSATION
DAMPENER
3/4"
3/4"
HORN
SILENCE
3/4"-SS TUBING
ANTI-FOAM
VENDOR
3/4" 3/4"
VENDOR
SP
018
3/4"-SS TUBING
2"
D
ET 10
38
TO V-44118
3/4"-KP-246005-PJG(0.4)
FI
112
3/4"
PG
057
INSTR.
6
PT
055
2"
3/4"-KP-246003-PJG(0.4)
SS TUBING PJG(0.4)
RV
030
1000 L
TOTE TANK
(REMOVABLE)
SP
014A
FI
110
2"
1"-VA-246016-PAB
CSC
1"-VA-246018-PAB
2"x1"
HS
015
R/S
I
009
06/13/11
04/20/11
03/01/11
01/10/11
12/02/10
HS
023
REV
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
CURB
CURB
SHELL CANADA
QUEST CCS PROJECT
A
7
P-24606 3
ANTI-FOAM INJECTION PUMP
MATERIAL:
INSULATION TYPE/THK:
TRIM:
160 L/hr
3850 kPa
0.75 kW
CASING
316 SS
NONE /
INTERNALS
316 SS
SCALE: NONE
SHELL DWG NO.:
246.0000.000.041.014
REV.
246.014
RATED FLOW:
DIFF. PR.:
DRIVER:
HORN
TEST
V-24607
CONDENSATE FLASH DRUM
SIZE:
DESIGN PR. & TEMP:
MATERIAL(VESSEL/INTERNALS):
INSULATION TYPE/THK:
TRIM:
E-24606A /B
LP COND. / DEMIN WATER EXCHANGER
RATED DUTY:
SURFACE AREA:
DESIGN PRESS:
DESIGN TEMP:
MATERIAL:
INSULATION TYPE/THK:
TRIM:
CONDENSATE
HOT
1150 kPa-g / FV
150 C / 150 C
PLATES: 304 SS
FRAME: CS
/
SCL-246030-SAB
WI-246020-UJB(0.4)
ET 10
100
8"-SCL-246002-SAB
246.003
COLD
1450 kPa-g / HV
125 C / 125 C
/
8"
5156140
C-2
13.5 MW (TOTAL)
ET 10
100
8"-SCL-246005-SAB
246.004
6"
5156140
C-2
5242525
C-2
6"
ET 10
75
8"
1-1/2"
1-1/2"
D
?
C-2
TW
055
1-1/2"
1-1/2"
?
C-2
TW
057
1-1/2"
TW
051
246.101
12681
TO V-25102
1-1/2"
D
?
C-2
?
C-2
HOLDS:
CSO
5242525
C-2
12454
1-1/2"
TW
054
1-1/2"
6"-WI-246011-UJB(0.4)
E-24606B
1-1/2"
TW
053
DEMIN WATER
246.023
1-1/2"
ET 10
50
1-1/2"
1-1/2"
?
C-2
?
C-2
1-1/2"
TW
056
D
?
C-2
?
C-2
5245480
C-2
ET 10
50
6"-WI-246010-UJB(0.4)
6"
CSO
5245480
C-2
C
246.003
4"
LV
005
FC
LV
006
FC
4"
6"x4"
FROM LX-005
13140
1-1/2"
6"
FROM P-24610A/B
13139
1-1/2"
D
TW
052
6"x4"
12270
6"-WI-246006-UJB(0.4)
E-24606A
246.004
FC
C-1
4"x3"
3/4" B
5115227
C-2
CSO
5156140
C-1
2"
4"-VA-246014-SAB
5156862
C-1
5070551
C-2
2"
C-1
ULB SAB
10"
5156140
?
TC
050
12"
PP
8"
8"-SC-246016-SAB
ET 10
75
TX
050
3"
5156140
C-1
5115277
C-3
3/4"
5156140
C-1
FROM FT-030
ET 10
50
4"x3"
FO
C-1
RECYCLED CONDENSATE
4"-SC-246016-SAB
246.021
5156140
C-1
12127
FROM E-24607
V-24607
5158143
2" C-2
HHLL=3800 mm
5158143
C-2
LG
025
HLL=2900 mm
ET 10
38
3"
5156863
C-1
FROM COLLECTION
5158143
2" C-1
LLLL=250 mm
03/01/11
01/10/11
12/02/10
ISSUED
DATE
DESCRIPTION
248.002
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
12427
FROM V-24805
SHELL CANADA
5158143
2" C-1
5158143
C-2
A
TT
050
04/20/11
HP CONDENSATE
2"-SCH-248002-SAG
TWO PHASE FLOW
5115277
C-3
SLOPE
1-1/2"
ET 10
88
RECOVERED CONDENSATE
10"-SC-246002-SAB
12128
TO P-24608A/B
246.021
246.0000.000.041.020
REV.
246.020
3"-SCL-246012-SAB
ET 10
38
3/4"
246.029
TO LC-025
5300 mm
12457
246.021
12129
2"
LLL=1150 mm
07/11/11
LEVEL SIGNAL
LT
025
24"
MW
5
REV
MAG
2"
LP CONDENSATE
12130
TV
050
4"x3"
8"x4"
FC
030
2"x1-1/2"
12126
FROM TK-25101
C-1
4"
246.027
5115227
C-2
2"x1-1/2"
6"x4"
8"x6"
FO 12"x10"
C-1
ET 10
88
V
5115277
C-2
CONDENSATE
6"-SC-246011-SAB
START-UP
3/4"
?
C-2
12664
PV
061A
ET 10
75
6"-SC-246XXX-SAB
ET 10
75
246.030
2"-GI-246005-ULB
GI
1-1/2"
5119160
C-2
PCV
060
ET 10
75
6"x4"
033
3/4"
PT
061
3/4"
2"-GI-246006-ULB
SET@
75 kPa-g
CSO
?
C-1
2"
5119160
C-2
TO ATMOSPHERE
CV FAILURE
AT SAFE LOCATION
3L4
SET@
500 kPa-g
6"-VA-246015-SAB
RV
8"-SC-246001-SAB
PV
061B
5156140
C-1
PC
061
C-1
3/4"
10"
SPLIT
12" 12"x10"
4"x3"
RV
034
?
C-1
4"-VA-246019-ULB
12"-VA-246020-SAB
6"
CV FAILURE
2J3
SET@
90 kPa-g
5156140
?
TO ATMOSPHERE
AT SAFE LOCATION
6"
TO ATMOSPHERE
AT SAFE LOCATION
6"x4"
FROM LX-006
E-24607A /B
CONDENSATE COOLER
RATED DUTY: 0.7 MW (TOTAL)
SURFACE AREA: TBD
TEMA TYPE: BEU
SHELL
DESIGN PRESS: 1200 kPa-g / FV
DESIGN TEMP: 150 C / 150 C
MATERIAL:
/
INSULATION TYPE/THK:
5
TRIM: SC-246040-SAB
CWR-246035-UAB
RECYCLED CONDENSATE
246.020
12127
TUBE
1200 kPa-g /
/ 58 C
/
ET 10
38
4"-SC-246016-SAB
ET 10
38
NNF
TO V-24607
ET 10
38
6"x4"
TT
062
3"
D
5115227
C-2
5115273
C-2
5156140
C-2
BACK
FLUSH
ET 10
50
6"x4"
246.006
TO V-24602
COOLED CONDENSATE
2"-SC-246017-SAB
12123
246.022
246.025
CWS
6"-CWS-246031-UAB
5307521
C-2
1-1/2"
12120
RS
6"x4"
TI
062
12131
TO P-24609A/B
3/4"
HOLDS:
WATER MAKE-UP
2"-SC-246020-SAB
E-24607B
RS
E-24607A
TW
064
6"x4"
1-1/2"
246.025
CWR
6"-CWR-246014-UAB
CSO
5307521
C-2
12119
5156140
C-2
6"x4"
5115273
C-2
1-1/2"
LC
025
4"-SC-246007-SAB
LL
ET 10
50
6"
5115227
C-2
FC
C-1
12129
FROM LT-025
RECOVERED CLEAN
CONDENSATE
6"-SC-246008-SAB
5156140
C-1
12654
246.027
TO TK-25101
ET 10
38
FLUSHING CONDENSATE
2"-SC-246010-SAB
12579
246.034
TO DISTRIBUTION
LL
HOA
MATERIAL:
INSULATION TYPE/THK:
TRIM:
04/20/11
03/01/11
01/10/11
12/02/10
3/4"
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
PP
SHELL CANADA
?
C-1
3/4
"
P-24608B
D
5115227
C-1
P-24608A /B 3
RECOVERED CLEAN CONDENSATE PUMP
RATED FLOW:
DIFF. PR.:
DRIVER:
5163480
C-1
?
C-1
3/4"
?
C-1
5115227
C-1
D
5115227
C-1
5115227
C-1
3/4"
5156140
C-1
07/11/11
D
5115227
C-1
8"-SC-246004-SAB
3/4
"
P-24608A
SP
023B
3/4"
5115227
C-1
3/4"
D
3/4"
R/S
PP
?
C-1
246.012
PP
3/4"
6"-SC-246005-SAB
?
C-1
3/4"
D
5115227
C-1
5156140
C-1
8"-SC-246003-SAB
3/4"
5115227
C-1
3"
FROM V-24607
10"x8"
SP
023A
5115227
C-1
ET 10
50
HIS
018
5163480
C-1
ET 10
50
V
10"-SC-246002-SAB
I
012
D
5115227
C-1
3/4"
12125
REV
SEL
3/4"
PP
5156140
C-1
5156140
C-1
HS
119
I
012
RECOVERED CONDENSATE
HS
018A
6"-SC-246006-SAB
HIS
017
R/S
CONDENSATE
4"-SC-246009-SAB
TO TK-24601 / Tk-24602
4
HOA
HS
017A
ET 10
38
183.0 m^3/hr
602 kPa
30.5 kW
CASING
INTERNALS
CS
CS
5
/
SC-246041-SAB
SC-246042-SAB
246.0000.000.041.021
REV.
012
START-UP
246.021
PT
065
?
C-2
246.020
246.020
12128
NC
5156140
C-2
4"
TO FC-030
PI
065
C-2
FT
030
12130
011
6"
5156140
C-1
246.020
LEVEL SIGNAL
LV
025
6"
3/4"
3/4"
D
5115227
C-2
ET 10
50
6"x4"
3/4"
TW
061
D
FLOW SIGNAL
241.022
13030
FROM FC-241076
FI
076
I
018
LL
FX
076
FLOW SIGNAL
242.022
13031
FROM FC-242076
ET 10
38
WASH WATER
2"-SCH-246003-SAG
12133
241.022
TO V-24119 / V-24219
3/4"
?
C-2
I
014
PT
070
PI
070
LL
HOA
HOA
HS
020A
HS
021A
I
018
SEL
HS
122
I
011
I
011
HIS
021
I
014
R/S
?
C-1
3/4"
3/4"
SAB
2"-SCH-246002-SAG
?
C-1
3/4"
2"-SC-246019-SAG
3/4
"
P-24609A
?
C-1
D
5115277
C-1
C-1
SAB SAG
?
C-1
?
C-1
SAG
?
C-1
FROM E-24607
?
C-1
3/4"
2"-SC-246018-SAG
PP
C-1?
?
C-1
?
C-1
3/4"
ET 10
38
3/4"
3/4"
PP
?
C-1
3/4
"
P-24609B
D
5115277
C-1
07/11/11
04/20/11
03/01/11
01/10/11
12/02/10
B
REV
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
SHELL CANADA
QUEST CCS PROJECT
A
R
P-24609A /B
WATER MAKE-UP PUMPS
3
RATED FLOW:
DIFF. PR.:
DRIVER:
MATERIAL:
INSULATION TYPE/THK:
TRIM:
9.9 m^3/hr
2741 kPa
7.5 kW
CASING
INTERNALS
CS
CS
/
4
SCH-246XXX-SAG
SCH-246XXX-SAG
246.0000.000.041.022
REV.
246.022
246.021
2"-SC-246017-SAB
?
C-1
12123
3/4"
COOLED CONDENSATE
PP
3/4"
3/4"
ET 10
38
PP
?
C-1
5063246
C-1
2"-SCH-246001-SAG
?
C-1
I
014
5063246
C-1
R/S
?
C-1
HIS
020
I
018
HOLDS:
DEMIN WATER
ET 10
50
6"-WI-246006-UJB(0.4)
12270
246.020
TO E-24606
C-2
RV
032
FROM LC-251001D
PI
075
ET 10
50
O/C
HIS
027
I
015
FC
035
HV
027
3/4"
PT
075
6"x4"
HOA
SI
025
HS
025A
XL
025
6"x4"
CSO
5242525
C-1
LOCAL/ VFD
REMOTE FAULT
XA
025
B
5134289
C-2
4"
5242525 5248450
C-1 C-1
FO
C-1
3/4"
?
C-1
5242525
C-1
?
C-2
6"
6"-WI-246021-UJB(0.4)
3/4"
C
TO GRADE
LOCAL/ VFD
REMOTE FAULT
HOA
SI
026
HS
026A
XL
026
XA
026
3/4"
3/4"
VFD
HIS
026
R/S
I
015
4"-WI-246005-UJB(0.4)
PP
?
C-1
3/4"
4"-WI-246004-UJB(0.4)
PP
3/4"
PP
?
C-1
D
5134289
C-1
?
C-1
P-24610A
5242525
C-1
3/4"
3/4
"
3/4"
6"-WI-246003-UJB(0.4)
6"-WI-246002-UJB(0.4)
5242525
C-1
FROM FV-251001
?
C-1
3/4"
ET 10
50
?
C-1
3/4
"
P-24610B
D
5134289
C-1
07/11/11
04/20/11
03/01/11
01/10/11
12/02/10
B
REV
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
SHELL CANADA
QUEST CCS PROJECT
A
R
P-24610A /B 3
DEMIN WATER SUPPLY PUMPS
RATED FLOW:
DIFF. PR.:
DRIVER:
MATERIAL:
INSULATION TYPE/THK:
TRIM:
92.5 m^3/hr
503 kPa
26.0 kW
CASING
INTERNALS
316 SS
316 SS
/
5
WI-246031-UJB(0.4)
WI-246032-UJB(0.4)
246.0000.000.041.023
REV.
246.023
6"-WI-246001-UJB(0.4)
5134289
C-1
3/4"
246.101
3/4"
12137
4
PP
DEMIN WATER
VFD
5248450
C-1
I
015
?
C-2
?
C-1
R/S
5134289
C-1
HIS
025
?
C-2
5248450
C-1
ET 10
50
ET 10
50
4"-WI-246009-UJB(0.4)
C-1
CSO
5242525
C-1
251.103
4"x3"
4"x3"
SP
4"-WI-246008-UJB(0.4)
SET POINT
CSO
5242525
C-1
FT
035
BLOCKED DISCHARGE
3L4
SET@
1450 kPa-g
HOLDS:
INSTRUMENT SIZING TO BE CONFIRMED DURING DETAILED ENGINEERING.
PUMP SIZING TO BE CONFIRMED PENDING SHELL COOLING WATER SURVEY &
FINAL HEAT EXCHANGER COOLING WATER FLOWRATES.
DESIGN CONDITIONS TO BE CONFIRMED.
PUMP SELECTION, SIZING, TYPE, NUMBER AND LAYOUT FOR COOLING WATER
PUMPS.
TOTAL REQUIRED FLOW WILL NOT CHANGE.
XHIS
006
I
016
XYI
006
O/C
12135
246.025
TO DISTRIBUTION
s
A/S
XZT
006
XV
006
24"
24"-CWS-246002-UAB
UG
AG
TW
070
30"-CWS-246001-UAB
30"-CWS-282015-UAB
N/A
5280764 30"x24"
C-1
FO
C-1
ET 10
24"
D
5115273
C-1
1-1/2"
5307853
C-1
N/A
ET 10
030
ET 10
88
5307853
C-1
N/A ET 10
"
3/4
D
5115273
C-1
HIS
030
ET 10
88
"
3/4
D
5115273
C-1
016
P-24611A
5115273
C-1
HS
030A
2"
JSLL
?
C-1
5115273
C-1
HOA
6
3/4"
SP
024B
R/S
5280764
C-1
5280764
C-1
2"
30"-CWS-246004-UAB
2"
5115273
C-1
JSLL
031
HOA
HS
031A
5115273
C-1
?
C-1
PP
5115273
C-1
ET 10
5115273
C-1
3/4"
5307853
C-1
N/A
3/4"
ET 10
88
5115273
C-1
6
?
C-1
2"
SP
024A
3/4"
30"-CWS-246003-UAB
D
5115273
C-2
3/4"
PP
ET 10
88
?
C-1
3/4"
D
5115273
C-2
3/4"
PP
24"-CWS-246006-UAB
3/4"
24"-CWS-246005-UAB
PP
N/A
ET 10
30"-CWS-246001-UAB
016
P-24611B
HIS
031
R/S
G
07/11/11
04/20/11
03/01/11
01/10/11
12/02/10
B
REV
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
SHELL CANADA
QUEST CCS PROJECT
A
R
HOLD
P-24611A/B 3
COOLING WATER BOOSTER PUMP
MATERIAL:
INSULATION TYPE/THK:
TRIM:
3118.0 m^3/hr
260 kPa
225.0 kW
CASING
INTERNALS
CS
CS
/
5
CWS-246036-UAB
CWS-246037-UAB
246.0000.000.041.024
REV.
246.024
RATED FLOW:
DIFF. PR.:
DRIVER:
30"-CWS-246001-UAB
5307853
C-1
HOLD
4
5115273
C-1 3/4"
ET 10
N/A
3/4"
5307853
C-1
24"
FROM HEADER
1
ET 10
50
E-24703
COMPRESSOR 12321
3RD STAGE
247.003
COOLER
CWS
6"-CWR-247004-UAB
ET 10
63
6"-CWS-246013-UAB
ET 10
63
6"-CWR-247005-UAB
ET 10
63
6"-CWS-246014-UAB
ET 10
63
N/A
ET 10
ET 10
N/A
N/A
ET 10
6"x4"
10"x6"
247.003
CWR
12895
CWR
12894
CWS
C-24701
LUBE OIL
COOLING
ET 10
N/A
10"x6"
ET 10
N/A
ET 10
N/A
N/A
ET 10
10"x6"
12352
5156140
C-3
ET 10
N/A
10"x6"
ET 10
63
10"x6"
6"-CWS-246015-UAB
10"x6"
ET 10
63
10"x6"
E-24705
COMPRESSOR 12351
5TH STAGE
247.005
COOLER
CWS
6"-CWR-247006-UAB
10"x6"
247.005
CWR
12"x6"
6"x4"
4"
12"x6"
N/A
ET 10
HOLDS:
ET 10
N/A
4"
6"-CWR-246014-UAB
ET 10
63
246.021
CWR
247.004
CWR
E-24704
COMPRESSOR 12344
4TH STAGE
247.004
COOLER
CWS
2"-CWR-247003-UAB
ET 10
63
2"-CWS-246012-UAB
HOLD
16"x12"
HOLD
16"x12"
12322
12345
E-24607
CONDENSATE
246.021
COOLER
CWS
12119
?
C-3
6"-CWS-246031-UAB
12120
ET 10
38
2"-CWS-246032-UAB
ET 10
38
246.028
CWS
LCP-XXX
CONDENSATE
RECOVERY
246.028
SAMPLING
CWR
ET 10
38
2"-CWR-246015-UAB
ET 10
38
12434
12433
247.002
CWR
ET 10
63
6"-CWS-246011-UAB
ET 10
63
13047
12311
247.001
CWR
10"-CWS-246025-UAB
E-24701
COMPRESSOR 12364
1ST STAGE
247.001
COOLER
CWS
6"-CWR-247001-UAB
ET 10
63
6"-CWS-246010-UAB
ET 10
63
3"-CWR-248001-UAB
ET 10
50
12363
248.001
CWR
12918
248.001
CWS
3"-CWS-246009-UAB
ET 10
50
12919
2"
?
C-2
ET 10
63
18"x6"
ET 10
30"x24"
24"x18"
30"-CWS-246016-UAB
30"x16"
16"-CWS-246008-UAB
N/A
pH
AE
001
AIT
001
AI
001
L
G
07/11/11
04/20/11
03/01/11
01/10/11
12/02/10
ET 10
63
18"x6"
24"x18"
30"x24"
ET 10 N/A
TO UTILITY/COGEN CWS
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
16"-CWR-246017-UAB
30"-CWR-282015-UAB
282.001
REV
TW
075
UG AG
282 246
30"-CWR-246016-UAB
30"x16"
3/4"
S-1
SHELL CANADA
30"-CWS-246007-UAB
FROM P-24611A/B
A
R
246.0000.000.041.025
REV.
246.025
12135
E-24701
TEG COOLER
PIPING
INST
CWR
246.009
246.009
CWS
12271
13046
E-24605B
LEAN AMINE
TRIM COOLER
10"-CWS-246008-UAB
12"-CWS-246030-UAB
246.005
CWS
12274
246.005
CWR
12"-CWR-246012-UAB
12898
10"-CWS-246023-UAB
12899
CWR
246.008
246.008
CWS
10"-CWR-246006-UAB
13146
246.005
CWS
12"-CWS-246029-UAB
246.005
CWR
12"-CWR-246011-UAB
13049
12"-CWS-246020-UAB
E-24601B
STRIPPER
OVERHEAD
CONDENSER
E-24605A
LEAN AMINE
TRIM COOLER
18"x12"
12896
13048
CWS
246.008
246.009
CWS
12"-CWS-246018-UAB
18"x12"
12"-CWR-246003-UAB
18"x12"
12957
CWR
246.008
246.009
CWR
12"-CWR-246001-UAB
18"x12"
13147
E-24601A
STRIPPER
OVERHEAD
CONDENSER
E-24604A/B
LEAN AMINE
COOLER
E-24702
COMPRESSOR 12300
2ND STAGE
247.002
COOLER
CWS
6"-CWR-247002-UAB
S-24603
CO2 VENT STACK
HOLDS:
FE
080B
2"
4
TI
080
2"
TT
080
4"
AP
005
S-24603
2"
4
FE
080A
VENT GAS
13011
246.032
FQI
080
FT
080
8"
8"x6"
6"-VA-247009-PJB(C)
FREE DRAINING
DERRICK SUPPORT
STRUCTURE
VENT GAS
24"-VA-247001-PJB(0.4)
FREE DRAINING
24"
MW
6"
PJB(C)
?
3"
C-2
?
2"
LIT
030
LI
030
ET 10
50
2"-WP-246004-PJB
07/11/11
04/20/11
03/01/11
01/10/11
12/02/10
NC
?
REV
C-1
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
8
POSWS
SHELL CANADA
QUEST CCS PROJECT
A
R
SCALE: NONE
SHELL DWG NO.:
246.0000.000.041.026
REV.
246.026
PJB(C)
PJB
246.032
PJB(0.4)
12474
HOLDS:
INSTRUMENT SIZING TO BE CONFIRMED DURING DETAILED ENGINEERING.
FI
085
CONDENSATE
ET 10
50
6"-SC-246011-SAB
START-UP
RECOVERED CLEAN
CONDENSATE
ET 10
50
6"-SC-246008-SAB
PROM P-24608A/B
RECOVERED CLEAN
CONDENSATE
ET 10
50
6"-SC-246008-SAB
AP
003
2"
246.101
12615
TO TK-25101
C-2
PIPING
INSTR.
ET 10
38
3"-P-246026-PJB(0.4)
FROM P-24603A/B
246.006
12653
WASTE WATER
WASTE WATER
ET 10
38
?
C-2
2"
?
C-1
HOLD
12614
246.101
TO WWTP 271
3
S-1
PJB(0.4)
DAB
4"-WP-246002-PJB(0.4)
3/4"
4"x3"
?
C-2
ET 10
38
SP
025
WASTE WATER
2"-WP-246003-DAB
246.013
NNF
12294
FROM P-24607
INDOOR TUBING
PP 25
PP
25
316 SS TUBING
RECOVERED CLEAN
CONDENSATE
12430
TO AE-003
246.028
07/11/11
04/20/11
03/01/11
01/10/11
12/02/10
B
REV
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
SHELL CANADA
QUEST CCS PROJECT
A
R
246.0000.000.041.027
REV.
OUTDOOR TUBING
ET 10
246.027
246.021
5097550
C-2
12654
MIN
TO V-24607
NC
5156140
?
FT
085
246.020
12126
RECOVERED CLEAN
CONDENSATE
12430
246.027
FROM P-24608A/B
PP
25
316 SS TUBING
?
?
4.
FLUOR
RC
VENDOR
HOLDS:
TO SINK (TYP.)
1"
5115273
?
FLUOR
VENDOR
NC
INDOOR OUTDOOR
ET 10
38
2"-CWR-246015-UAB
246.025
CWR
12433
1"
5115273
?
FLUOR
VENDOR
TO SINK (TYP.)
INDOOR OUTDOOR
ET 10
38
2"-CWS-246032-UAB
246.025
CWS
12434
SET@
69 kPa-g
TCV
090
PCV
085
SET@
79 kPa-g
RV
035
TG
091
FI
093
FI
091
FI
092
PG
086
AE
002
RC
HOLD
AE
003
TO SINK (TYP.)
PCV
087
SET@
61 kPa-g
AI
003
AIT
003
5
TO SINK (TYP.)
I
017
ANALYZER INDICATION
07/11/11
251.XXX
04/20/11
03/01/11
01/10/11
12/02/10
TO UNIT 251
HH
REV
pH
AI
002
LL
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
ANALYZER INDICATION
251.XXX
TO UNIT 251
GRAB SAMPLE
SHELL CANADA
SAMPLE SINK
A
VENDOR
FLUOR
1"-DO-246XXX-SAB
SCALE: NONE
SHELL DWG NO.:
246.0000.000.041.028
REV.
246.028
GRADE
CC
CC
LP STEAM
36"-SL-246001-SAB
246.101
12438
H
50
FROM HEADER
D
ET 10
38
U/S #2
2"x1"
H
38
2"-SL-246002-SAB
3"x2"
2"x1"
LP STEAM
H 38
H 50
LP STEAM
H
50
1"-SCL-246010-SAB
ET 10
38
246.002
2"x1"
2"-SCL-246019-SAB
2"x1"
STEAM OUT
246.002
12694
2"-SL-246015-SAB
LP STEAM
H
38
2"-SL-246016-SAB
H
50
3"-SL-246004-SAB
247.011
12610
TO E-24709A/B
36"x10"
FROM V-24601
LP STEAM
H
38
3"x2"
CONDENSATE
3"x2"
TO E-24603A
12695
2"-SL-246018-SAB
H
38
246.003
24"-SL-246009-SAB
12685
3"-SCL-246009-SAB
TO E-24603B
U/S #9
H
38
24"-SL-246002-SAB
36"x24"
12665
36"x24"
246.004
247.012
12449
TO E-24709C/D
C
10"x8"
TO V-24601
CONDENSATE
ET 10
38
2"-SCL-247008-SAB
247.012
12456
2"-SCL-246011-SAB
ET 10
38
3"-SCL-246012-SAB
ET 10
38
LP CONDENSATE
H
38
TO V-24607
2"-SCL-246013-SAB
H
38
2"-SL-246014-SAB
ET 10
38
2"-SCL-246018-SAB
2"x1"
2"x1"
ET 10
38
ET 10
38
ET 10
38
2"-SL-246020-SAB
ET 10
H
50
2"-SCL-246022-SAB
07/11/11
04/20/11
03/01/11
01/10/11
12/02/10
U/S #5
U/S #6
2"-SL-246021-SAB
2"x1"
2"x1"
2"x1"
2"x1"
H
50
2"x1"
B
REV
U/S #7
ET 10
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
2"-SCL-246023-SAB
2"-SL-246022-SAB
2"-SCL-246024-SAB
SHELL CANADA
2"-SCL-247002-SAB
2"-SL-246011-SAB
3"-SL-246009-SAB
2"-SCL-246015-SAB
ET 10
SCALE: NONE
SHELL DWG NO.:
246.0000.000.041.029
REV.
246.029
247.007
12455
FROM E-24708A/B
TO E-24708A/B
CONDENSATE
247.007
12447
LP STEAM
FROM TK-24601
12661
246.012
TO TK-24601
CONDENSATE
246.012
12884
LP STEAM
2"-SL-246013-SAB
2"-SCL-246017-SAB
H
38
H
38
H
38
ET 10
38
2"-SCL-246016-SAB
2"-SL-246010-SAB
H
38
ET 10
H
50
ET 10
38
3"-SL-246014-SAB
ET 10
38
2"-SCL-246014-SAB
H
38
8"x3"
2"-SL-246008-SAB
2"x1"
2"-SL-246007-SAB
2"x1"
2"x1"
12611
FROM E-24709A/B
U/S #10
12457
U/S #4
246.020
247.011
U/S #8
H
38
2"-SCL-247005-SAB
U/S #11
2"x1"
2"-SL-246006-SAB
CONDENSATE
ET 10
38
U/S #12
U/S #3
2"x1"
ET 10
38
H
50
FROM E-24709C/D
3"
? 5178780
C-2 C-2
INSTRUMENT AIR
12459
246.101
2"
3"-AI-246001-ULB
?
?
2"-AI-246001-ULB
FROM HEADER
2"
UTILITY AIR
12458
246.101
? ?
C-2 C-2
2"-AU-246001-ULB
FROM HEADER
FI
094
2"
?
?
2"
NITROGEN
12460
246.101
? ?
C-2 C-2
FT
094
2"-GI-246001-ULB
FROM HEADER
2"
1"-GI-246002-ULB
U/S #2
?
?
1"-AU-246002-ULB
C
NITROGEN
12697
2"
2"-GI-246003-ULB
1"-AU-246009-ULB
?
?
TO V-24601
U/S #9
246.002
1"-GI-246022-ULB
U/S #3
1"-GI-246004-ULB
1"-AU-246003-ULB
2"
2"
?
?
?
?
1"-AU-246008-ULB
246.020
12664
U/S #8
NITROGEN
2"-GI-246005-ULB
TO V-24607
?
?
2"
?
?
2"
1"-GI-246021-ULB
NITROGEN
246.013
12461
2"-GI-246007-ULB
NITROGEN
TO V-24606
2"-GI-246020-ULB
12808
247.001
TO V-24701
1"-GI-246008-ULB
U/S #4
1"-AU-246004-ULB
12995
247.010
TO E-24707
NITROGEN
2"-GI-246018-ULB
12425
TO V-24806
07/11/11
04/20/11
03/01/11
01/10/11
12/02/10
248.002
REV
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
U/S #10
1"-AU-246011-ULB
U/S #5
U/S #6
U/S #7
NITROGEN
246.010
13159
SHELL CANADA
2"-GI-246014-ULB
1"-GI-246024-ULB
NITROGEN
13141
2"-GI-246012-ULB
1"-AU-246012-ULB
U/S #12
246.010
1"-GI-246025-ULB
246.0000.000.041.030
REV.
2"-GI-246010-ULB
246.030
12729
1"-GI-246023-ULB
U/S #11
246.012
2"-GI-246026-ULB
NITROGEN
2"-AU-246013-ULB
1"-GI-246017-ULB
2"-GI-246013-ULB
1"-AU-246007-ULB
13142
1"-GI-246016-ULB
246.010
1"-AU-246006-ULB
NITROGEN
1"-GI-246009-ULB
1"-AU-246005-ULB
1"-AU-246010-ULB
SP
026
SP
027
HOLDS:
FAH
095
FSH
095
FAH
096
FSH
096
LAL
095
LSL
095
LAL
096
LSL
096
UA
UA
UA
UTILITY WATER
12470
246.101
UA
ET 10
38
2"-WU-246001-UAB
FROM HEADER
COMPRESSION AREA/
TEG DEHYDRATION AREA
U/S #2
1"-WU-246003-UAB
1"-WU-246004-UAB
2"x1"
U/S #3
1"-WU-246010-UAB
U/S #9
U/S #4
1"-WU-246009-UAB
1"-WU-246005-UAB
U/S #8
07/11/11
04/20/11
03/01/11
01/10/11
12/02/10
1"-WU-246008-UAB
1"-WU-246007-UAB
1"-WU-246006-UAB
REV
1"-WU-246011-UAB
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
U/S #10
SHELL CANADA
QUEST CCS PROJECT
1"-WU-246012-UAB
U/S #5
U/S #6
U/S #11
U/S #7
U/S #12
246.0000.000.041.031
REV.
246.031
1"-WU-246013-UAB
247.001
FROM RV-247013
20"-VA-247002-PJB(0.4)
DO NOT POCKET
3
CO2 VENT
247.001
FROM PV-247001
FREE DRAINING
3
246.026
TO S-24603
CO2
VENT GAS
247.010
6"-VA-247009-PJB(C)
6"-VA-247009-PJB(C)
FREE DRAINING
13011
246.026
TO S-24603
07/11/11
04/20/11
03/01/11
01/10/11
12/02/10
B
REV
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
SHELL CANADA
QUEST CCS PROJECT
A
R
246.0000.000.041.032
REV.
12327
12474
246.032
12471
VENT GAS
24"-VA-247001-PJB(0.4)
24"-VA-247001-PJB(0.4)
DO NOT POCKET
FROM P-24603A/B
246.006
2"-DM-246011-DAB
DM
12391
FROM E-24605A
246.008
DM
2"-DM-246063-DAB
ET 10
50
2"-DM-246065-DAB
ET 10
50
12596
FROM P-24605B
246.009
DM
12262
FROM FV-246020
246.011
DM
AMINE DRAINS
ET 10
75
2"-DM-246057-DAB
ET 10
50
2"-DM-246043-DAB
ET 10
50
6"-DM-246061-DAB
FREE DRAINING
13037
246.013
TO V-24606
13152
FROM P-24602A/B/C
246.011
DM
13151
AMINE DRAINS
ET 10
75
6"-DM-246060-DAB
FREE DRAINING
13036
246.013
TO V-24606
C
FROM E-24602A
246.001
DM
2"-DM-246004-DAB
ET 10
50
2"-DM-246001-DAB
ET 10
50
2"-DM-246026-DAB
ET 10
50
2"-DM-246024-DAB
ET 10
50
2"-DM-246029-DAB
ET 10
50
13144
FROM E-24602B
246.001
DM
12227
FROM V-24608
246.010
DM
12687
FROM V-24604
246.010
DM
12387
FROM V-24609
246.010
DM
12390
FROM HV-246040
246.010
2"-DM-246030-DAB
DM
ET 10
50
13136
FROM P-24605
246.012
DM
2"-DM-246055-DAB
13155
FROM P-24605
246.012
2"-DM-246XXX-DAB
DM
12620
FROM P-24604
246.012
2"-DM-246056-DAB
DM
13153
FROM P-24604
246.012
2"-DM-246050-DAB
DM
07/11/11
04/20/11
03/01/11
01/10/11
12/02/10
B
REV
13154
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
AMINE DRAINS
6"-DM-246006-DAB
FREE DRAINING
12477
246.013
TO V-24606
SHELL CANADA
FROM RV-246020
246.010
DM
2"-DM-246064-DAB
2"-DM-246025-DAB
13134
FROM RV-246003
246.009
DM
13150
FROM RV-246021
246.010
DM
2"-DM-246022-DAB
2"-DM-246062-DAB
12240
FROM RV-246002
246.008
DM
13132
SCALE: NONE
SHELL DWG NO.:
246.0000.000.041.033
REV.
246.033
ET 10
75
FLUSHING CONDENSATE
2"-SC-246012-SAB
12462
246.010
TO V-24604/V-24608/V-24609
CONDENSATE
12579
246.021
ET 10
38
2"-SC-246010-SAB
FROM P-24608A/B
FLUSHING CONDENSATE
2"-SC-246013-SAB
12463
246.013
TO V-24605
07/11/11
04/20/11
03/01/11
01/10/11
12/02/10
REV
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
SHELL CANADA
QUEST CCS PROJECT
A
R
SCALE: NONE
SHELL DWG NO.:
246.0000.000.041.034
REV.
246.034
MH-246004
MH-246003
C
HS
R/S
HS
PP
P-246012
ET 10
2"-WW-246001-UAB
MH-246005
MH-246002
3/4"
TO HMU1/2 MH-006
MH-246001
TEG/DEHYDRATION CATCHMENT
MH-246006
07/11/11
REV
ISSUED
DATE
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
SHELL CANADA
QUEST CCS PROJECT
A
P-246012
STORM WATER PUMP
RATED FLOW:
DIFF. PR.:
DRIVER:
INSULATION TYPE/THK:
HEAT TRACE MEDIA/TEMP:
10.00 m^3/hr
112.00 kPa
0.30 kW @
/
2.
CASING
INTERNALS
MATERIAL:
TRIM:
SCALE: NONE
SHELL DWG NO.:
246.0000.000.041.035
REV.
240.031
LI
246.035
STORMWATER
H
I
LT
4
3
TO E-24802
2
246.011
FROM P-24602A/B/C
12238
LEAN AMINE
TO E-24602A/B
12686
14"-P-246081-DAG
5242525
C-1
3/4"
1"-SCL-285003-SAB
2"x1"
2"-SCL-285001-SAB
6"-SC-285210-SAB
6"-WI-285003-UJB(0.4)
10"-P-285156-DJE(0.4)
14"-P-285155-DAG
ET 10
50
ET 10
50
ET 10
50
ET 10
63
2"-SS-285058-SAG
H
50
ET 10
38
36"-SL-285145-SAB
H
50
2"-AU-285148-ULB
2"-WU-285041-UAB
3"-AI-285150-ULB
4"-WP-285034-PJB(0.4)
2"-GI-285068-ULB
6"-WI-285002-UJB(0.4)
FROM HEADER
LP STEAM
FROM HEADER
UTILITY AIR
FROM HEADER
UTILITY WATER
FROM HEADER
FROM HEADER
TO V-44118
LEAN AMINE
285.217
TO TK-25102
285.217
FROM V-44118
RICH AMINE
285.217
TO TK-25101
285.217
RECOVERED CLEAN
CONDENSATE
285.217
LP CONDENSATE
285.217
285.217
285.217
285.217
285.217
INSTRUMENT AIR
TO WWTP 271
285.217
FROM HEADER
NITROGEN
FROM HEADER
WASTE WATER
285.217
285.217
DEMIN WATER
2"-AU-285149-ULB
07/11/11
ISSUED FOR PHA III
04/20/11
ISSUED FOR ESTIMATE
03/01/11
ISSUED FOR PHA II
01/10/11
ISSUED FOR CLIENT REVIEW
12/02/10
ISSUED FOR INTERNAL REVIEW
REV
ISSUED
DATE
DESCRIPTION
SCALE: NONE
SHELL DWG NO.:
BY
CKD
PRS
246.0000.000.041.101
CS
PDP
MC
APE
SHELL CANADA
QUEST CCS PROJECT
G
FILE:\\F:\1025\DRAWINGS\CO2\246\246.101.pid MODEL DATE:7/7/2011 11:16:46 AM BY:ahm14887
ET 10
75
246.001
?
C-2
ET 10
50
?
C-2
10"-P-246002-DJE(0.4)
2"
RICH AMINE
FROM E-24606
3/4"
246.020
285
246
6"
3/4" 3/4"
D
5115277
?
ET 10
50
5115227
C-3
5115227
C-3
6"-WI-246007-UJB(0.4)
285
248
?
?
12681
ET 10
38
D
5156140
C-1
?
C-3
3/4"
H
ET 10
SAG SAB
?
?
6"
?
?
3/4" 3/4"
?
C-3
ET 10
50
?
C-1
2"
?
?
ET 10
38
FROM P-24608A/B
6"-SC-246008-SAB
?
C-1
2"
1"
246.027
H
50
1"
12615
12545
2"-SS-248001-SAG
C-1
2"
H
ET 10
RECOVERED CLEAN
CONDENSATE
248.002
TO DISTRIBUTION
12438
?
C-2
246.029
H
50
?
C-2
36"-SL-246001-SAB
LP STEAM
3/4"
TO DISTRIBUTION
246.030
3/4"
2"-AU-246001-ULB
?
C-3
12458
2"-GI-285069-ULB
UTILITY AIR
C-1
ET 10
38
ET 10
38
ET 10
50
246.101
12470
2"
5178780
C-1
3"
TO DISTRIBUTION
246.031
ET 10
38
?
C-2
2"-WU-246001-UAB
UTILITY WATER
3/4"
TO DISTRIBUTION
12459
246.030
?
C-2
3"-AI-246001-ULB
3/4"
INSTRUMENT AIR
5242525
C-1
4"
C-1
2"
2"
FROM P-24608A/B
246.027
?
C-2
12614
ET 10
38
4"-WP-246002-PJB(0.4)
WASTE WATER
2"-GI-246001-ULB
2"
TO DISTRIBUTION
246.030
12460
NITROGEN
6"
5242525
C-1
285
246
TO P-24610A/B
12137
ET 10
50
6"-WI-246001-UJB(0.4)
246.023
DEMIN WATER
4
1
HOLDS:
1"-SCL-285002-SAB
U/S #1
2"
?
C-3
2"
?
C-2
D
V-24701
COMPRESSOR SUCTION KO DRUM
2.5 MW
317.0 m^2
BXU
SHELL
385 kPa-g / HV
130 C / 150 C
CS + 3 mm 304L SS CLAD
H/
GC-247072-PJB(0.4)
DESIGN PRESS:
DESIGN TEMP:
MATERIAL:
INSULATION TYPE/THK:
TRIM:
UC SIGNAL
TI
002
PI
003
PI
021
UY
001B
HOLDS:
12"x10"
SURGE
COUNTER
ET 10
75
12"
UQI
001
TO UV-001
TT SIGNAL
AUTO/MAN
HC
022
247.010
12331
FROM TT-057
PT SIGNAL
CSO
?
C-1
12"-GC-247003-PJB(0.4)
247.010
12569
FROM PT-021
ET 10
N/A
246.030
GI
247.010
12571
001A
UC SIGNAL
UC
5
TO UV-003
TI
057
247.010
12578
001B
PDI
029
TUBE
1200 kPa-g /
58 C /
DUPLEX 2205 + 0.38 mm CA
/
CWR-247010-UAB
UC
CSC
5242525
C-1
C-1
N/A
ET 10
10"
18"x10"
RATED DUTY:
SURFACE AREA:
TEMA TYPE:
(V)
3/4"
?
C-1
RV
013B
C-1
10"x8"
POWER
FAILURE
8T10
SET@
385 kPa-g
10"x8"
TO S-24603
CSO
?
C-1
10"-GC-247032-PJB(0.4)
FREE DRAINING
RV
013A
18"x10"
N/A
ET 10
20"
20"-VA-247002-PJB(0.4)
12809
20"x18"
18"-VA-247013-PJB(0.4)
246.032
?
C-1
3/4"
POWER
FAILURE
8T10
SET@
385 kPa-g
E-24701
COMPRESSOR 1st STAGE COOLER
10"-VA-247012-PJB(0.4)
N/A
ET 10
SIZE:
DESIGN PR. & TEMP:
MATERIAL(VESSEL/INTERNALS):
INSULATION TYPE/THK:
TRIM:
2"-GI-246020-ULB
24"-GC-247045-PJB(0.4)
DO NOT POCKET
FREE DRAINING
12808
247.010
12326
FROM C-24701H
ANALYZER FAST LOOP
FREE DRAINING
E
001
HH
FROM AX-001
PC
PC
034
023
PERFORMANCE
CONTROLLER
3/4"
3/4"
?
C-2
HLL=700 mm
MAG
LT
001
HHLL=800 mm
5134289
C-2
START/STOP
HIS
001
24"
MW
?
C-2
2"
2"
5115273
C-2
H
38
CO2
30"-GC-247006-PJB(0.4)
TWO PHASE FLOW
3/4"
PT
024
247.002
12305
TO V-24702
?
C-2
3/4"
3/4"
(V)
PI
024
(V)
?
C-2
E
001
6"-CWS-246010-UAB
PZTE
023
E
001
07/11/11
04/20/11
03/01/11
01/10/11
12/02/10
L
REV
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
I
MCC
3"x2"
HSE
MIN
3"
?
C-1
C-2
3"
FC
C-1
2"
5134289
C-2
?
C-1
1-1/2"
2"x1-1/2"
3/4"
5097550
C-2
2"x1-1/2"
3"-DM-247001-PJB(0.4)
5134289
C-2
?
C-2
FREE DRAINING
?
C-2
(V)
246.025
CWS
?
PDT
029
001
3/4"
?
C-2
3/4"
ON/OFF
LLL=250 mm
?
C-2
PV
023
?
C-2
C-2
2"
2"
3/4"
PT
003
3/4"
LG
001
RS
PT
004
12363
TI
059
TT
059
RS
NNF
2"
001
RS
TO V-24606
ET 10
38
30"-GC-247005-PJB(0.4)
PI
004
3/4"
?
C-2
3"
4"
BACK FLUSH
5156140
C-2
1-1/2"
1-1/2"
2"
2"
30"x24"
OUTSIDE
INSIDE
V-24701
3"
2"
30"x24"
?
C-2
HH
LTE
002
24"
6"
GWR
LV
001
3/4"
5307521
C-2
NC
?
C-2
3"
N/A
H
24"
TI
003
TT
003
?
C-2
2"-DM-247002-PJB(0.4)
LL
PTE
002
5134289
C-2
LC
001
12626
HH
?
C-2
24"
E-24701
PP
E
001
36"
GAP
246.013
DO NOT POCKET
3"
MIN
H
25
KO LIQUIDS
3/4"
?
C-2
?
C-2
3/4"
3/4"
?
C-3
3"
FREE DRAINING
2"
12364
C-24701A
001
?
C-1
FROM V-24803
3/4"
248.003
36"-GC-247004-PJB(0.4)
36"
3/4"
3"-GC-248004-PJB(0.4)
DO NOT POCKET
10
30"x24"
30"x24"
246.025
CWR
6"-CWR-247001-UAB
CSO
5307521
C-2
1-1/2"
RS
NC
?
C-2
5097550
C-2
2"-GC-247002-PJB(0.4)
ET 10
38
2"
24"-GC-247001-PJB(0.4)
5134289
C-2
ET 10
N/A
12367
24"
3/4"
?
C-1
FLASHED CO2
1-1/2"
T.S.
36"
DO NOT POCKET
TW
052
?
C-1
FROM V-24602
SP
001
ET 10
50
6"
3/4"
246.006
36"-GC-246001-PJB(0.4)
PJB(0.4)
3/4"
V
5134289
C-2
ET 40 N/A 1-1/2"
ET 40 OUTSIDE INSIDE
88
36"
5242893
C-2
12368
ET 10
N/A
?
C-1
3/4"
CO2
2"
ULB
DO NOT POCKET
NNF
?
C-2
2"
FO
C-1
3/4"
PT
001
S-4
N/A
ET 10
5242526
C-1
24"
PC
001
N/A
ET 10
ET 10
75
SP
002
TT
002
TTE
001
PV
001
PT
034
?
C-2
PP
?
C-1
EMERGENCY STOP
SHELL CANADA
OUTSIDE INSIDE
CASING DRAIN
3"-WP-247001-PJB(0.4)
247.002
13160
FROM C-24701B/C/D
TO GRADE AT
SAFE LOCATION
C-24701A
CO2 COMPRESSOR 1st STAGE
RATED CAPACITY:
DIFF. PR.:
DRIVER :
MATERIAL :
INSULATION TYPE/THK:
TRIM:
79877 Nm^3/hr
3
9163 kPa
16500 kW
304 SS
PP /
GC-247071-PJB(0.4)
247.0000.000.041.001
REV.
24"-VA-247001-PJB(0.4)
NNF
12471
13165
247.001
246.032
247.009
V-24702
COMPRESSOR 2nd STAGE KO DRUM
SIZE:
DESIGN PR. & TEMP:
MATERIAL(VESSEL/INTERNALS):
INSULATION TYPE/THK:
TRIM:
E-24702
COMPRESSOR 2nd STAGE COOLER
RATED DUTY:
SURFACE AREA:
TEMA TYPE:
DESIGN PRESS:
DESIGN TEMP:
MATERIAL:
INSULATION TYPE/THK:
TRIM:
3.1 MW
507.0 m^2
BJU
SHELL
530 kPa-g / HV
130 C / 150 C
CS + 3 mm 304L SS CLAD
PP /
GC-247075-PJB(0.4)
TUBE
1200 kPa-g /
58 C /
DUPLEX 2205 + 0.38 mm CA
/
CWR-247011-UAB
D
HOLDS:
ET 10
50
6"-CWR-247002-UAB
246.025
CWR
TW
053
CSO
5307521
C-2
6"
12300
1-1/2"
2"
2"
?
C-2
RS
?
C-2
26"x24"
2"
?
C-2
26"
ET 45
88
1-1/2"
4"
BACK FLUSH
5156140
C-2
1-1/2"
6"
30"-GC-247007-PJB(0.4)
PP
?
C-2
?
C-2
ET 10
50
6"-CWS-246011-UAB
3"
TI
006
SP
004
TT
006
246.025
CWS
12311
H
38
OUTSIDE
INSIDE
CO2
24"-GC-247009-PJB(0.4)
TWO PHASE FLOW
FREE DRAINING
T.S.
5242893
C-3
3/4"
PP
3"
FREE DRAINING
30"
30"
OUTSIDE INSIDE
ET 45 N/A
TT
005
20"
5307521
C-2
TTE
004
20"
RS
24"x20"
001
24"x20"
TI
005
24"-GC-247008-PJB(0.4)
HH
2"
E-24702
247.003
12310
TO V-24703
1-1/2"
PI
006
FREE DRAINING
30"
GWR
LTE
004
5134289
C-2
HHLL=800 mm
?
C-1
3/4"
07/11/11
04/20/11
03/01/11
01/10/11
12/02/10
5134289
C-2
REV
3/4"
B
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
MIN
?
C-1
3"
C-2
FC
C-1
3"x2"
3" ?
C-2
?
C-2
5242893
3"
2"
2"
5134289
C-2
3/4"
?
C-1
3"-P-247002-PJB(0.4)
2"
C-24701B
2"
2"
5134289
C-2
TO V-24602
ET 10
38
2"-P-247002-PJB(0.4)
5134289
C-2
LG
003
ON/OFF
12244
?
C-2
3"
4
LLL=250 mm
3/4"
246.006
3/4"
24"
MW
LV
003
KO LIQUIDS
HLL=700 mm
2"
RS
LT
003
?
C-2
RS
2"
MAG
?
C-2
3/4"
B
?
C-2
LC
003
001
3/4"
SHELL CANADA
CASING DRAIN
CASING DRAIN
3"-WP-247001-PJB(0.4)
3"-WP-247001-PJB(0.4)
TO SAFE LOCATION
247.003
12304
FROM C-24701C/D
C-24701B
CO2 COMPRESSOR 2nd STAGE
RATED CAPACITY:
DIFF. PR.:
DRIVER :
MATERIAL :
INSULATION TYPE/THK:
TRIM:
79877 Nm^3/hr
9163 kPa
3
16500 kW
304 SS
PP /
GC-247074-PJB(0.4)
247.0000.000.041.002
REV.
247.002
247.001
13160
3/4"
V-24702
GAP
PT
005
HH
PT
006
3/4"
FROM E-24701
30"-GC-247006-PJB(0.4)
TWO PHASE FLOW
DO NOT POCKET
247.001
12305
PI
005
H
38
?
C-1
CO2
V-24703
COMPRESSOR 3rd STAGE KO DRUM
SIZE:
DESIGN PR. & TEMP:
MATERIAL(VESSEL/INTERNALS):
INSULATION TYPE/THK:
TRIM:
E-24703
COMPRESSOR 3rd STAGE COOLER
RATED DUTY:
SURFACE AREA:
TEMA TYPE:
DESIGN PRESS:
DESIGN TEMP:
MATERIAL:
INSULATION TYPE/THK:
TRIM:
3.0 MW
425.0 m^2
BEU
SHELL
1200 kPa-g / HV
130 C / 150 C
CS + 3 mm 304 L SS CLAD
PP /
GC-247078-PJB(0.4)
TUBE
1200 kPa-g /
58 C /
DUPLEX 2205 + 0.38 mm CA
/
CWR-247012-UAB
HOLDS:
NUMBER OF RVs AND SIZING TO BE CONFIRMED DURING DETAILED ENGINEERING.
INSTRUMENT SIZING TO BE CONFIRMED DURING DETAILED ENGINEERING.
ET 10
50
246.025
CWR
6"-CWR-247004-UAB
HH
TI
008
001
TW
054
CSO
5307521
C-2
6"
12321
1-1/2"
FROM E-24702
SP
006
PI
007
24"
GWR
5134289
C-2
3/4"
V-24703
3/4"
HLL=700 mm
?
C-2
5134289
C-2
PI
008
PT
008
3/4"
?
C-2
HH
?
C-2
RS
2"
2"
PP
?
C-2
BACK 4"
FLUSH
5156140
C-2
3/4"
?
C-2
?
C-2
2"
22"
ET 10
50
246.025
CWS
6"-CWS-246013-UAB
12322
CO2
20"-GC-247013-PJB(0.4)
TWO PHASE FLOW
12320
247.004
TO V-24704
RS
?
C-2
HHLL=800 mm
2"
1-1/2"
RS
2"
E
001
LTE
006
PT
007
OUTSIDE
INSIDE
RS
?
C-2
2"
FREE DRAINING
TT
009
E-24703
6"
ET 10
38
3/4"
22"
5307521
C-2
24"-GC-247009-PJB(0.4)
TWO PHASE FLOW
PP
CSO
?
C-1
2"
247.002
12310
H
38
2"
2"-GC-247010-PJB(0.4)
CO2
TI
009
FREE DRAINING
V
5134289
C-1
1-1/2"
?
C-2
22"x20"
24"
1-1/2"
DO NOT POCKET
3/4"
ET 45
88
?
C-3
C-1
24"-GC-247011-PJB(0.4)
2"
2"-VA-247004-PJB(0.4)
RV
004
ET 10
38
2"x1"
N/A
ET 10
FREE DRAINING
24"
OUTSIDE INSIDE
ET 45 N/A
TT
008
T.S.
FIRE
1D2
SET@
530 kPa-g
TTE
007
22"x20"
TO ATMOSPHERE
AT SAFE LOCATION
20"-GC-247012-PJB(0.4)
2"
3"
GAP
MAG
LC
005
LT
005
LG
005
24"
MW
C-24701C
3"
LV
005
?
C-1
3/4"
?
C-1
04/20/11
03/01/11
01/10/11
12/02/10
D
C-2
REV
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
CASING DRAIN
3"-WP-247001-PJB(0.4)
3"-WP-247001-PJB(0.4)
TO SAFE LOCATION
247.004
13161
FROM C-24701D
SHELL CANADA
QUEST CCS PROJECT
A
R
C-24701C
CO2 COMPRESSOR 3rd STAGE
RATED CAPACITY:
DIFF. PR.:
DRIVER :
MATERIAL :
INSULATION TYPE/THK:
TRIM:
79877 Nm^3/hr
9163 kPa
3
16500 kW
304 SS
PP /
GC-247077-PJB(0.4)
247.0000.000.041.003
REV.
247.003
12304
CASING DRAIN
247.002
07/11/11
FC
C-1
MIN
2"
TO V-24602
?
C-1
2"
2"
2"
13033
2"
5134289
C-2
246.006
ET 10
38
2"-P-247003-PJB(0.4)
3/4"
KO LIQUIDS
3/4"
?
C-2
5134289
C-2
LLL=250 mm
?
C-2
3/4"
5134289
C-2
3/4"
ON/OFF
2"
?
C-1
2"
V-24704
COMPRESSOR 4th STAGE KO DRUM
SIZE:
DESIGN PR. & TEMP:
MATERIAL(VESSEL/INTERNALS):
INSULATION TYPE/THK:
TRIM:
E-24704
COMPRESSOR 4th STAGE COOLER
RATED DUTY:
SURFACE AREA:
TEMA TYPE:
DESIGN PRESS:
DESIGN TEMP:
MATERIAL:
INSULATION TYPE/THK:
TRIM:
2.9 MW
343.0 m^2
BEU
SHELL
2200 kPa-g / HV
130 C / 150 C
CS + 3 mm 304L SS CLAD
PP /
GC-247081-PJE(0.4)
TUBE
1700 kPa-g /
58 C /
DUPLEX 2205 + 0.38 mm CA
/
CWR-247013-UAB
HOLDS:
ET 10
50
6"-CWR-247005-UAB
246.025
CWR
TW
055
CSO
5307521
C-2
6"
12344
1-1/2"
2"
6"x4"
?
C-2
SP
007
20"
10"
RS
2"
2"
?
C-2
3"
20"
HHLL=800 mm
LT
007
LG
007
PT
009
HH
3/4"
5134289
C-2
PJB(0.4)
PJE(0.4)
24"
MW
?
C-2
C-24701D
C-1
3/4"
3/4"
3"
ET 10
38
?
C-1 PJE(0.4)
PJB(0.4)
2"-P-247006-PJB(0.4)
247.005
07/11/11
04/20/11
03/01/11
KO LIQUIDS
01/10/11
12346
12/02/10
FROM V-24705
ET 10
38
B
REV
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
KO LIQUID
2"-P-247010-PJB(0.4)
247.009
12372
FROM V-24707
C-2
2"
MIN
2"
?
C-1
5134289
C-2
?
C-2
?
C-2
3/4"
5134289
C-2
3/4"
1-1/2"
2"x1-1/2" 2"
2"x1-1/2" FC
C-1
LLL=250 mm
2"
3/4"
?
C-1
2"
5134289
C-2
ON/OFF
TO V-24602
2"
5307521
C-2
?
C-2
3/4"
?
C-2
3"
PT
010
2"
ET 10
38
TO V-24705
RS
HLL=700 mm
MAG
GWR
E
001
LTE
008
2"
2"
2"-P-247004-PJB(0.4)
247.005
RS
GAP
13032
12348
D
ET 10
38
KO LIQUID
2"-P-247005-PJB(0.4)
TWO PHASE FLOW
247.006
12353
FROM V-24706
SHELL CANADA
QUEST CCS PROJECT
CASING DRAIN
13161
TO SAFE LOCATION
R
C-24701D
CO2 COMPRESSOR 4th STAGE
247.0000.000.041.004
REV.
247.004
247.003
3"-WP-247001-PJB(0.4)
5134289
C-2
3/4"
V-24704
?
C-2
246.006
RS
FREE DRAINING
1-1/2"
CO2
16"-GC-247017-PJE(0.4)
TWO PHASE FLOW
?
C-2
ET 10
38
2"
KO LIQUIDS
246.025
CWS
PI
010
FREE DRAINING
LC
007
TT
012
PI
009
LV
007
6"-CWS-246014-UAB
3/4"
3/4" 3/4"
FROM E-24703
ET 10
50
TI
012
PP
20"-GC-247013-PJB(0.4)
TWO PHASE FLOW
1-1/2"
2"
CSO
5242893
C-1
3"
3"-GC-247014-PJB(0.4)
247.003
12320
1-1/2"
T.S.
3/4"
V
5134289
C-1
CO2
ET 45
88
BACK 4"
FLUSH
5156140
C-2
12345
C-1
20"-GC-247015-PJB(0.4)
OUTSIDE
INSIDE
DO NOT POCKET
ET 10
50
OUTSIDE INSIDE
ET 45 N/A
18"
TT
011
?
C-3
ET 10
6"-VA-247005-PJB(0.4)
FREE DRAINING
N/A
RV
006
TTE
010
6"
CONTROL VALVE
FAILURE
3L4
SET@
1200 kPa-g
TI
011
E-24704
PP
TO ATMOSPHERE
AT SAFE LOCATION
HH
18"
18"x16"
E
001
16"-GC-247016-PJE(0.4)
?
C-2
18"x16"
?
C-2
V-24705
COMPRESSOR 5th STAGE KO DRUM
SIZE:
DESIGN PR. & TEMP:
MATERIAL(VESSEL/INTERNALS):
INSULATION TYPE/THK:
TRIM:
E-24705
COMPRESSOR 5th STAGE COOLER
RATED DUTY:
SURFACE AREA:
TEMA TYPE:
3.0 MW
281.0 m^2
BEU
SHELL
DESIGN PRESS: 4200 kPa-g / HV
DESIGN TEMP: 130 C / 150 C
MATERIAL: CS + 3 mm 304L SS CLAD
INSULATION TYPE/THK: PP /
TRIM: GC-247084-PJG(0.4)
TUBE
3300 kPa-g /
58 C /
DUPLEX 2205 + 0.38 mm CA
/
CWR-247014-PJE(0.4)
HOLDS:
NUMBER OF RVs AND SIZING TO BE CONFIRMED DURING DETAILED ENGINEERING.
INSTRUMENT SIZING TO BE CONFIRMED DURING DETAILED ENGINEERING.
ET 10
50
6"-CWR-247006-UAB
246.025
CWR
TW
056
CSO
5307521
C-2
6"
12351
1-1/2"
PJB(0.4) ET 10
PJE(0.4) ET 25
2"
?
C-2
PI
012
PT
012
001
3/4" 3/4"
2"
?
C-2
?
C-2
HHLL=800 mm
HLL=700 mm
?
C-2
2"
?
C-2
2"
?
C-2
3/4" 3/4"
?
C-2
?
C-2
3/4"
?
C-2
3/4"
2"
2"
?
C-2
3"
2"
3/4"
?
C-2
5134289
C-2
PJE(0.4)
PJG(0.4)
C-24701E
C-1
3/4"
3/4"
?
C-2
C-2
07/11/11
04/20/11
03/01/11
01/10/11
12/02/10
B
REV
PJB(0.4)
3/4"
C-2
?
C-2
3"
?
C-1 PJG(0.4)
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
5134289
C-2
?
C-2
2"
?
C-2
2"
3/4"
2"
3/4"
5134289
C-2
3/4"
LLL=250 mm
2"
2"
?
C-1
D
OUTSIDE INSIDE
CASING DRAIN
3"-WP-247002-PJB(0.4)
247.006
13163
SHELL CANADA
FROM C-24701F/G/H
TO GRADE AT
SAFE LOCATION
R
C-24701E
CO2 COMPRESSOR 5th STAGE
SCALE: NONE
SHELL DWG NO.:
247.0000.000.041.005
REV.
247.005
ET 25
38
MIN
FC 2"x1-1/2"
C-1
2"
C-2
1-1/2"
2"
2"x1-1/2"
HH
V-24705
?
C-1
PT
013
008
2"
16"
5134289
C-2
3/4"
ET 10
PJB(0.4)
PJE(0.4)
ET 25
2"
TO V-24706
2"-P-247007-PJE(0.4)
5134289
C-2
TO V-24704
ET 10
38
247.006
12350
24"
MW
3/4"
12346
CO2
14"-GC-247021-PJG(0.4)
TWO PHASE FLOW
SP.
ET 25
38
LG
009
ON/OFF
247.004
LV
009
246.025
CWS
12352
RS
2"-P-247006-PJB(0.4)
KO LIQUIDS
6"-CWS-246015-UAB
RS
ET 10
50
3/4"
PP
10"
MAG
LT
009
1-1/2"
FREE DRAINING
LTE
010
LC
009
6"
GWR
GAP
H
TT
015
PI
013
16"
FREE DRAINING
FROM E-24704
1-1/2"
16"-GC-247017-PJE(0.4)
TWO PHASE FLOW
OUTSIDE
INSIDE
PJE(0.4)
UAB
BACK 4"
FLUSH
5156140
C-2
6
FREE DRAINING
CSO
?
C-1
2"
247.004
1-1/2"
3/4"
2"-GC-247018-PJE(0.4)
12348
ET 45
75
16"-GC-247019-PJE(0.4)
V
5134289
C-1
CO2
OUTSIDE INSIDE
ET 45 N/A
TI
015
TT
014
T.S.
C-1
TTE
013
DO NOT POCKET
ET 10
38
RV
008
?
C-3
2"-VA-247006-PJB(0.4)
14"
2"x1"
N/A
ET 10
TI
014
E-24705
5307521
C-2
FIRE
1D2
SET@
2200 kPa-g
HH
14"
RS
E
001
PP
TO ATMOSPHERE
AT SAFE LOCATION
UAB
PJE(0.4)
?
C-2
RS
14"-GC-247020-PJG(0.4)
2"
V-24706
COMPRESSOR 6th STAGE KO DRUM
SIZE:
DESIGN PR. & TEMP:
MATERIAL(VESSEL/INTERNALS):
INSULATION TYPE/THK:
TRIM:
D
HOLDS:
NUMBER OF RVs AND SIZING TO BE CONFIRMED DURING DETAILED ENGINEERING.
INSTRUMENT SIZING TO BE CONFIRMED DURING DETAILED ENGINEERING.
HH
E
001
ET 45
75
C-1
TI
018
2"
PI
015
FREE DRAINING
14"
GWR
E
001
?
C-2
?
C-2
MAG
?
C-2
C-24701F
3/4"
5134289
C-2
?
C-2
5134289
C-2
3/4"
3/4"
5134289
C-2
3/4"
LLL=250 mm
1" 2"x1"
2"x1"
FC
C-1
2"
?
C-1
ET 25
38
2"
C-1
?
C-1 PJG(0.4)
PJB(0.4)
MIN
?
C-1
?
C-2
2"
?
C-2
TWO PHASE
FLOW
C-2
2"
2"
TO V-24704
2"
5134289
C-2
ET 10
38
12353
24"
MW
2"
2"-P-247009-PJG(0.4)
3/4"
247.004
5134289
C-2
5134289
C-2
3/4"
ON/OFF
ET 10
PJB(0.4)
PJG(0.4)
ET 25
KO LIQUID
LV
011
HH
1-1/2"
HLL=700 mm
LG
011
2"
2"-P-247005-PJB(0.4)
?
C-2
3/4"
?
C-2
?
C-2
TT
018
RS
HHLL=800 mm
2"
3/4" 3/4"
RS
LT
011
2"
5134289
C-2
LC
011
2"
3/4"
GAP
V-24706
5134289
C-2
2"
3/4"
3/4"
5134289
C-2
LTE
012
PT
015
07/11/11
04/20/11
03/01/11
01/10/11
12/02/10
B
REV
CASING DRAIN
247.005
13163
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
CASING DRAIN
3"-WP-247002-PJB(0.4)
3"-WP-247002-PJB(0.4)
TO SAFE LOCATION
247.009
13162
FROM C-24701G/H
SHELL CANADA
QUEST CCS PROJECT
A
R
C-24701F
CO2 COMPRESSOR 6th STAGE
247.0000.000.041.006
REV.
FROM E-24705
10"
14"-GC-247021-PJG(0.4)
TWO PHASE FLOW
247.006
247.005
12350
SP
009
3/4"
CO2
TO E-24706
OUTSIDE
?
?
14"
ET 25
38
247.007
12313
3/4" 3/4"
PP
INSIDE
CO2
12"-GC-247024-PJG(0.4)
DO NOT POCKET
2"
2"-GC-247022-PJG(0.4) 2"
CSO
?
C-1
V
5134289
C-1
PP
1-1/2"
PP
3/4"
1-1/2"
?
C-3
PJB(0.4) ET 10
PJG(0.4) ET 25
FREE DRAINING
OUTSIDE INSIDE
ET 45 N/A
14"-GC-247023-PJG(0.4)
TT
017
3/4" 3/4"
RV
010
ET 10
38
2"-VA-247007-PJB(0.4)
TTE
016
?
C-2
PT
016
FIRE
1D2
SET@
4200 kPa-g
2"x1"
N/A
ET 10
TI
017
T.S.
TO ATMOSPHERE AT
SAFE LOCATION
PI
016
2
E-24708A /B
COMPRESSOR 6th STAGE COOLER SPACE HEATERS
E-24706
COMPRESSOR 6th STAGE COOLER
RATED DUTY:
SURFACE AREA [FINNED]:
TUBE DESIGN PR. & TEMP:
TUBE MATERIAL:
DRIVER & Nos.:
WINTERIZATION:
INSULATION TYPE/THK:
TRIM:
RATED DUTY:
TYPE:
MATERIAL: 304 SS
TRIM: (A) SCL-247020-SAB
(B) SCL-247021-SAB
3.9 MW
9596.0 m^2
6500 kPa-g @ 130 C / HV @ 150 C
304L SS + 0.38 mm CA
22.0 kW & 2
TYPE 3, MODE C
/
GC-247087-PJG(0.4)
HOLDS:
CO2
247.006
12313
PP
12"-GC-247024-PJG(0.4)
FROM C-24701F
TV
021B
(V)
C-1
TX
021B
FC
E-24706
TV
021A
C-1
TX
021A
8"
8"
8"
8"
FO
1-1/2"
1-1/2"
TW
043
PP
3/4" 3/4"
TW
042
?
C-2
(V)
CO2
H
MIN 10D
12"-GC-247031-PJG(0.4)
FREE DRAINING
12314
247.009
TO V-24707
1-1/2"
C
FAN NO. 1
FAN NO. 2
TT
019
E
001
FROM HEADER
?
C-2
(V)
SI
001
?
C-2
TV
021C
3/4"
2"-SL-246011-SAB
TT
021B
TX
021C
C-1
2"
VFD
XL
002
XA
002
VFD
XA
003
LOCAL/ FAULT
REMOTE
XL
003
SI
002
FAULT LOCAL/
REMOTE
-SL-247001-SAB
FC
2"
FREE DRAINING
TI
021B
5115227
C-2
TX
021
5115227
C-2
TC
021
TT
021A
3/4"
246.029
12447
TI
021A
H
ET 10
LP STEAM
E
001
TC
019
TV
021D
C-1
FC
(V)
TX
021D
FREE DRAINING
HS
005
E-24708B
11 Jul 2011
MANUAL
HIS
002
R/S
I
001
HIS
003
I
001
R/S
07/11/11
04/20/11
03/01/11
01/10/11
12/02/10
-SCL-247001-SAB
REV
CONDENSATE
HS
003A
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
HOA
?
C-2
HOA
ISSUED
DATE
?
C-2
SHELL CANADA
QUEST CCS PROJECT
A
R
247.0000.000.041.007
REV.
247.007
TO HEADER
ET 10
38
2"-SCL-247002-SAB
5115227
C-2
12455
3/4"
246.029
HS
002A
HS
004
?
C-2
5115227
C-2
3/4"
D
E-24708A
R/S
MANUAL
?
C-2
R/S
-SL-247004-SAB
-SL-247003-SAB
-SL-247002-SAB
V-24707
TEG INLET SCRUBBER
SIZE:
DESIGN PR. & TEMP:
MATERIAL(VESSEL/INTERNALS):
INSULATION TYPE/THK:
TRIM:
V-24708
COMPRESSOR 7th STAGE KO DRUM
DO NOT POCKET
3/4"
NO
5242964
C-1
5134289
C-3
12"
12"
12"-GC-248001-PJG(0.4)
NO
5242964
C-1
ET 25
N/A
AI
001A
TO ATMOSPHERE AT
SAFE LOCATION
AI
001B
FI
005
FT
005
FI
006
12
FT
006
ET 10
38
HH
001
TI
026
TTE
025
TT
026
CO2 PURITY
TO ATMOSPHERE AT
SAFE LOCATION
TO ATMOSPHERE AT
SAFE LOCATION
AE
001B
2"x1"
C-1
PJB(0.4) ET 10
PJG(0.4) ET 25
3/4"
V
5134289
C-1
ET 45
75
12
FIRE
1D2
SET@
6500 kPa-g
RV
011
2"-VA-247008-PJB(0.4)
12375
AX
001
13165
N/A
ET 10
248.001
AT
001B
AE
001A
FROM V-24801
H2O
TO V-24801
CO2
AT
001A
247.001
248.001
12376
HOLDS:
N/A
ET 25
12"-GC-247038-PJG(0.4)
ET 25
H
CSC
5242963
C-1
10"
CO2
H
75
CSO
5242964
C-1
CSO
5242964
C-1
H
ET 25
12"
5134289
C-3
3/4"
12"
3/4"
5134289
C-3
ET 45 N/A
OUTSIDE
INSIDE
12"-GC-247040-PJG(0.4)
AP
001
1-1/2"
1-1/2"
10
CO2
10"-GC-247041-PJL(C)
2"
247.010
12325
TO C-24701H
13
TO ATMOSPHERE AT
SP
SAFE LOCATION
005
8
3/4" 3/4"
S-4A
?
C-1
5134289
C-2
T.S.
PI
026
3/4" 3/4"
?
C-2
?
C-2
PT
019
PJG(0.4)
PJL(C)
13162
07/11/11
04/20/11
03/01/11
01/10/11
12/02/10
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
LZTE
015
3/4"
C-1
?
C-1 PJL(C)
PJB(0.4)
APE
PEM CLIENT
APP
2"x1"
?
C-1
FC 2"x1"
C-1
LV
015
KO TEG
ET 10
38
248.003
12373
SHELL CANADA
ET 25 ET 10
PJG(0.4) PJB(0.4)
A
CASING DRAIN
3"-WP-247002-PJB(0.4)
TO SAFE LOCATION
C-24701G
CO2 COMPRESSOR 7th STAGE
RATED CAPACITY: 79877 Nm^3/hr
DIFF. PR.: 9163 kPa
3
DRIVER : 16500 kW
MATERIAL : 304 SS
INSULATION TYPE/THK: PP /
TRIM: GC-247091-PJL(C)
MC
PDP
2"
1"
3"-WP-247002-PJB(0.4)
CS
C-24701G
CASING DRAIN
247.006
2"-KP-247002-PJB(0.4)
2"
?
C-1
5134289
C-2
ET 25
38
PI
019
2"-KP-247001-PJG(0.4)
2"
12
11 Jul 2011
3/4" 3/4"
3/4"
5134289
C-2
3/4"
3/4"
3"
PT
026
12
REV
ON/OFF
SO
?
C-2
LYE
015
TI
027
3/4"
2"
?
C-2
TT
027
?
C-2
E
003
3/4"
?
C-2
?
C-2
LLL=250 mm
LT
015
2"
2"
5134289
C-2
2"
?
C-2
LC
015
5134289
C-2
?
C-1
?
C-2
5134289
C-2
2"
ET 25
38
2"
2"
3/4"
?
C-2
LG
015
TI
060
GAP
H
MAG
24"
MW
5134289
C-2
?
C-2
2"
?
C-2
?
C-2
2"x1"
?
C-2
HLL=700 mm
2"
FC
C-1
?
C-2
2"
MIN
2"x1"
?
C-2
MIN
?
C-1
2"
1"
5134289
C-2
?
C-2
TO V-24704
2"
?
C-2
HHLL=800 mm
LLL=250 mm
3/4"
2"
5134289
C-2
2"
2"
12372
ET 10
38
5134289
C-2
247.004
2"-P-247010-PJB(0.4)
?
C-2
2"
3"
2"-P-247011-PJG(0.4)
3/4"
KO LIQUID
2"
3/4"
LV
013
ET 10 ET 25
3/4"
PT
018
?
C-2
PJB(0.4) PJG(0.4)
3/4"
24"
MW
3/4"
ON/OFF
3/4"
2"
LG
013
5134289
C-2
LT
013
3/4"
?
C-2
MAG
2"
PI
018
V-24708
RS
LC
013
HLL=800 mm
?
C-2
?
C-2
GAP
2"
5134289
C-2
2"
5134289
C-2
3/4"
5134289
C-2
3/4"
V-24707
LTE
016
3/4"
12"
TT
060
3/4" 3/4"
12"
GWR
5134289
C-2
FREE DRAINING
LL
LT
017
SP
010
5134289
C-2
GWR
?
C-2
2"
3/4"
12"-GC-247031-PJG(0.4)
TWO PHASE FLOW
3/4"
FROM E-24706
E
003
5134289
C-2
247.007
12314
001
1-1/2"
3/4" 3/4"
PP
HH
5134289
C-2
CO2
3/4"
LI
017
1-1/2"
247.010
13166
FROM C-24701H
247.0000.000.041.009
REV.
ET 25
38
247.009
10"
DO NOT POCKET
12"
10"
PP
CSO
?
C-1
2"
2"
12"
?
C-3
RS
?
C-3
2"
RS
11
2"-GC-247039-PJG(0.4)
FREE DRAINING
13
CO2 VENT
6"-VA-247010-PJB(C)
DO NOT POCKET
N/A ET 120
PJB(C) PJL(C)
FREE DRAINING
TO S-24603
?
C-1
6"
6"-VA-247009-PJB(C)
C-1
?
C-1
4"x3"
12327
UV
003
3/4"
FO
C-1
UYE
003
V
5136407
C-1
HOLDS:
NUMBER OF RVs AND SIZING TO BE CONFIRMED DURING DETAILED ENGINEERING.
INSTRUMENT SIZING TO BE CONFIRMED DURING DETAILED ENGINEERING.
FO
4"
E
001
RV
012
CSO
5349470
C-1
246.032
3/4"
13039
BLOCKED DISCHARGE
3K6
SET@
14790 kPa-g
247.014
2"
?
C-1
UC SIGNAL
PX
034
247.001
12578
FROM UC-001B
E
002
E
001
FO
MIN
HH
PC
022
001
5
10"
5351323
C-1 INSIDE OUTSIDE
5136407
C-3
XYE
001
?
C-2
NC
?
C-2
VISIBLE
2"-GI-246019-ULB
246.030
GI
12995
8
7
A/S
FO
XZTE
001
10"
FC
2"
PG
028
XV
001
2"
6"
5343525
C-1
10"
5349475
C-1
C-1
ET 120 PP
PP
CO2
10"-GC-247043-PJL(C)
12332
247.011
TO E-24707A/B
ET 120
100
MIN
5351323
C-1
10"
?
C-3
SP
003B
3/4"
SP
003A
3/4"
PT
022
?
C-2
?
C-2
?
C-2
3/4" 3/4"
3/4" 3/4"
TO UC-001A/B
4"-GC-247046-PJL(C)
12569
PTE
020
3/4" 3/4"
247.001
PT
021
8"-GC-247044-PJL(C)
001
PT SIGNAL
5119160
C-2
FREE DRAINING
UV
001
E
002
3/4"
24"x8" C-1 FO
PJB(0.4) PJL(C)
N/A ET 120
3/4" 3/4"
TO V-24701
FREE DRAINING
ET 120
75
ET 120
75
12326
24"-GC-247045-PJB(0.4)
DO NOT POCKET
?
C-2
8"
? ?
C-2 C-2
FROM UC-001A
247.001
UZTE
001
2" 2"
247.001
12571
TT SIGNAL
1-1/2"
TT
057
12331
TO UC-001A/B
4
CO2
247.009
PP
10"-GC-247041-PJL(C)
FROM C-24701G
DO NOT POCKET
10
10"-GC-247042-PJL(C)
12325
1-1/2"
TTE
029
E
001
HH
07/11/11
04/20/11
03/01/11
01/10/11
12/02/10
ISSUED
REV
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
RS
ET 120
PP
C-24701H
?
C-1
3/4"
SHELL CANADA
?
C-1 PJL(C)
PJB(0.4)
CASING DRAIN
13166
3"-WP-247002-PJB(0.4)
TO SAFE LOCATION
C-24701H
CO2 COMPRESSOR 8th STAGE
RATED CAPACITY:
DIFF. PR.:
DRIVER :
MATERIAL :
INSULATION TYPE/THK:
TRIM:
79877 Nm^3/hr
9163 kPa
3
16500 kW
304 SS
PP /
GC-247092-PJL(C)
REV.
247.0000.000.041.010
247.010
247.009
247.001
3/4"
UYE
001
UC SIGNAL
2
E-24709A /B
CO2 COMPRESSOR AFTERCOOLER SPACE HEATERS
E-24707A 6
CO2 COMPRESSOR AFTERCOOLER
RATED DUTY:
SURFACE AREA [FINNED]:
TUBE DESIGN PR. & TEMP:
TUBE MATERIAL:
DRIVER & Nos.:
WINTERIZATION:
INSULATION TYPE/THK:
TRIM:
RATED DUTY:
TYPE:
MATERIAL: 304 SS
TRIM: (A) SCL-247025-SAB
(B) SCL-247024-SAB
10.3 MW 3
1385.0 m^2
14790 kPa-g @ 175 C
304L SS + 0.38 mm CA
22.0 kW & 2
TYPE 3, MODE C
/
GC-247093-PJL(C)
6
CO2
247.010
12332
CO2
PP
10"-GC-247043-PJL(C)
FROM C-24701H
12558
HOLDS:
247.012
TO E-24707B
TV
032B
(V)
TX
032B
C-1
FC
TV
032A
6"
(V)
TX
032A
E-24707A
6"
BAY A
C-1
6"
FO
6"
1-1/2"
1-1/2"
TW
047
PP
3/4" 3/4"
TW
046
?
C-2
6
CO2
6"-GC-247055-PJL(C)
MIN 10D
12556
247.014
C
FAN NO. 1
FAN NO. 2
TT
030
TI
032A
E
001
2"
TT
032A
TC
030
246.029
5115227
C-2
VFD
VFD
(V)
TX
032C
SI
005
V
3/4"
C-1
FC
247.014
12557
FROM TC-031
001
?
C-2
TV
032C
TC SIGNAL
XL
006
XA
006
XA
007
LOCAL/ FAULT
REMOTE
XL
007
FREE DRAINING
FROM HEADER
SP
?
C-2
5115227
C-2
12610
2"-SL-246015-SAB
2"
TT
032B
3/4"
LP STEAM
TI
032B
TX
032
H
ET 10
TC
032
SI
006
FAULT LOCAL/
REMOTE
2"-SL-247010-SAB
-SL-247009-SAB
TV
032D
C-1
FC
(V)
TX
032D
R/S
R/S
E-24709A
HS
012
HS
013
E-24709B
MANUAL
11 Jul 2011
MANUAL
HIS
010
2"-SCL-247006-SAB
?
C-2
5115227
C-2
3/4"
?
C-2
CONDENSATE
TO HEADER
HS
010A
ET 10
38
2"-SCL-247005-SAB
?
C-2
HIS
011
I
001
R/S
07/11/11
04/20/11
03/01/11
01/10/11
12/02/10
HOA
HS
011A
B
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
HOA
-SL-247012-SAB
5115227
C-2
12611
I
001
REV
3/4"
246.029
R/S
?
C-2
SHELL CANADA
QUEST CCS PROJECT
A
R
247.0000.000.041.011
REV.
-SL-247011-SAB
FREE DRAINING
247.011
PP
10"-GC-247043-PJL(C)
2
E-24709C /D
CO2 COMPRESSOR AFTERCOOLER SPACE HEATERS
E-24707B 6
CO2 COMPRESSOR AFTERCOOLER
RATED DUTY:
SURFACE AREA [FINNED]:
TUBE DESIGN PR. & TEMP:
TUBE MATERIAL:
DRIVER & Nos.:
WINTERIZATION:
INSULATION TYPE/THK:
TRIM:
RATED DUTY:
TYPE:
MATERIAL:
TRIM:
10.3 MW
3
1385.0 m^2
14790 kPa-g @ 175 C
304L SS + 0.38 mm CA
22.0 kW & 2
TYPE 3, MODE C
/
GC-247094-PJL(C)
304 SS
(C) SCL-247026-SAB
(D) SCL-247027-SAB
6
CO2
12558
247.011
PP
10"-GC-247043-PJL(C)
HOLDS:
FROM C-24701H
TV
035B
TX
035B
(V)
C-1
FC
E-24707B
TV
035A
6"
(V)
6"
BAY B
TX
035A
C-1
6"
6"
FO
1-1/2"
TW
048
1-1/2"
TW
049
6
CO2
6"-GC-247058-PJL(C)
MIN 10D
12560
247.014
1-1/2"
FAN NO. 1
2"
TT
035A
TT
033
TC
033
TX
035C
C-1
-SL-247015-SAB
FC
247.014
12561
FROM TC-031
XL
009
SI
008
FAULT LOCAL/
REMOTE
TV
035D
C-1
FREE DRAINING
-SL-247014-SAB
R/S
E-24709C
R/S
HS
016
HS
017
(V)
TX
035D
E-24709D
11 Jul 2011
MANUAL
I
001
HIS
015
I
001
HOA
HS
015A
HOA
R/S
07/11/11
04/20/11
03/01/11
01/10/11
12/02/10
B
REV
-SL-247016-SAB
R/S
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
?
C-2
5115227
C-2
?
C-2
SHELL CANADA
QUEST CCS PROJECT
A
R
247.0000.000.041.012
REV.
247.012
TO HEADER
ET 10
38
2"-SCL-247008-SAB
XA
009
FC
HS
014A
3/4"
12456
TC SIGNAL
E
001
-SL-247013-SAB
-SCL-247007-SAB
246.029
VFD
LOCAL/ FAULT
REMOTE
HIS
014
CONDENSATE
XA
008
?
C-2
5115227
C-2
3/4"
D
XL
008
MANUAL
?
C-2
SI
007
?
C-2
TV
035C
VFD
5115227
C-2
?
C-2
(V)
FREE DRAINING
FROM HEADER
3/4"
H
38
2"-SL-246016-SAB
SP
3/4"
246.029
12449
2"
TT
035B
5115227
C-2
LP STEAM
TI
035B
TX
035
H
ET 10
TC
035
TI
035A
E
001
FAN NO. 2
HOLDS:
INSTRUMENT SIZING TO BE CONFIRMED DURING DETAILED ENGINEERING.
CO2 VENT
247.010
13039
TO S-24603
6"-VA-247010-PJB(C)
DO NOT POCKET
?
C-1
6"
C-1
PJB(C)
PJL(C)
TO TC-030
NC
12557
247.011
3"
TC SIGNAL
TV
058
6"x3"
C-1
FC
12561
NC
?
C-1
3"
TO TC-033
3"
C
3
PI
025
CO2
12556
247.011
6"-GC-247055-PJL(C)
NC
?
C-1
247.012
3"
TC SIGNAL
FQI
004
MIN 10D
8"-GC-247059-PJL(C)
8"
FP
5349475
C-1
8"x4"
MIN 5D
8"x4"
6
5351323
C-1
TT
058
1-1/2"
7
8"
5349475
C-1
5136407
C-3
?
C-3
FT
004
3/4"
NC
5349470
C-1
4"
3/4"
V
5136407
C-1
3/4"
1-1/2"
3/4"
V
5136407
C-1
TC
058
NC
5349470
C-1
1-1/2"
TTE
041
?
C-2
TT
031
3/4" 3/4"
FROM E-24707B
4"
6"-GC-247058-PJL(C)
FI
004
3"
NC
5349470
C-1
PT
025
4"
7
CO2
8"
5349475
C-1
12993
MIN
TO PIPELINE
PJL(C)
11 Jul 2011
07/11/11
04/20/11
03/01/11
01/10/11
12/02/10
REV
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
SHELL CANADA
QUEST CCS PROJECT
A
R
247.0000.000.041.014
REV.
247.014
247.012
HH
4"
12560
E
002
NC
5349470
C-1
CO2
NC
5349470
C-1
TC
031
3"-GC-247027-PJL(C)
FROM E-24707A
RV
004
3"x2"
C-1
RATED DUTY:
SURFACE AREA:
TEMA TYPE:
DESIGN PRESS:
DESIGN TEMP:
MATERIAL:
INSULATION TYPE/THK:
TRIM:
3/4"
V
5134289
C-1
2"
190 kW
74.0 m^2
DOUBLE PIPE
SHELL
7200 kPa-g / HV
210 C / 150 C
CS
/
KP-248025-PAN
TUBE
1200 kPa-g /
58 C /
CS
/
CWR-248002-UAB
C-2
C-1
?
D
C-2
TW
011
2"
12"
2"
FI
003
5242963
C-2
24"
MW
2"
2"
5063244
C-2
6"x2"
2"
1-1/2"
6"x2"
3/4"
3"
246.025
CWR
ET 10
38
CSO
5156863
C-2
12918
2"
2"
RS
L
2" RS
FT
003
5063244
C-2
6"x3"
6"x3"
3"x2"
2" RS
E-24804A
TT
010
3"
3"
5242963
C-2
RS
2"
5134289
C-2
3/4"
3"
TC
010
3"-CWR-248001-UAB
1-1/2"
2"
TO V-24708
HOLDS:
ET 10
38
12"-GC-248001-PJG(0.4)
12616
FROM P-24801A/B
2"
ET 25
N/A
248.004
2"
E-24804B
ET 10
38
12375
?
C-3
247.009
C-1
FC
C-1
2"-KP-248016-PAN
ET 10
38
2"
2"-KP-248024-PAN
CO2
3/4"
2"-GC-248002-PJG(0.4)
1"
2"
2"x1"
LEAN TEG
ET 10
38
3/4"
2"x1"
ET 25
38
TV
010
5115273
C-2
2" 2"
ET 10
PJB(0.4)
PJG(0.4)
ET 25
E-24804A /B /C /D /E
LEAN TEG COOLER
V-24801
TEG ABSORBER
SIZE:
DESIGN PR. & TEMP:
MATERIAL(VESSEL/INTERNALS):
INSULATION TYPE/THK:
TRIM:
CSO
?
C-1
ET 10
38
2"x1"
3"-VA-248002-PJB(0.4)
CSC CSC
? ?
C-1 C-1
N/A
ET 10
FIRE
1E2
SET@
6500 kPa-g
PJG(0.4)
ET 25
ET 10
PJB(0.4)
TO ATMOSPHERE
AT SAFE LOCATION
2"
2"
RS
ET 10
38
2" RS
2"
ET 10
38
E-24804C
2"
2"
PDI
002
RS
PDT
002
2" RS
2"
ET 10
38
2"
2"
TO ATMOSPHERE
AT SAFE LOCATION
RS
3"x2"
3"
2"
2" RS
6
3/4"-VA-248001-PJG(0.4)
ET 25
38
E-24804E
7
N/A
ET 25
S-4A
V-24801
2"
?
C-2
E-24804D
ET 10
38
3"-CWS-246009-UAB
5156863
C-2
246.025
CWS
12919
BACK
FLUSH
11 Jul 2011
2"-KP-248021-PAN
2"
SO
2"
5134289
C-2
3/4"
MAG
LG
002
2"
2"
?
C-2
?
C-2
?
C-2
LT
002
LC
002
03/01/11
01/10/11
12/02/10
ISSUED
DATE
DESCRIPTION
LYE
002
CS
MC
PDP
APE
PEM CLIENT
APP
?
C-1
5134289
C-2
?
C-1
1-1/2" 1-1/2"
3/4"
1-1/2"
5134289
C-2
1-1/2"
3/4"
?
C-2
2"
3"x1-1/2"
FC
C-1
1-1/2"
?
C-1
1-1/2"
3"x1-1/2"
?
C-1
ET 10
38
RICH TEG
3"-KP-248002-PJG(0.4)
TWO PHASE FLOW
12379
248.002
TO E-24801
ET 10
38
CSC
5096787
C-1
PRS
SHELL CANADA
LV
002
3" 3"-KP-248001-PJG(0.4)
CKD
E
003
BY
5134289
C-2
?
C-2
04/20/11
3/4"
5134289
C-2
2"
REV
?
C-2
LLLL=300 mm
248.0000.000.041.001
REV.
LLL=700 mm
07/11/11
248.001
?
C-2
2"
5134289
C-2
NLL=880 mm
?
C-2
24"
MW
?
C-2
2"
3/4"
?
C-2
HLL=1050 mm
5134289
C-2
5134289
C-2
2"
5134289
C-2
2"
HHLL=1450 mm
3/4"
3/4"
12"
3/4"
GWR
3/4"
LL
LTE
001
5242963
C-2
5134289
C-2
5134289
C-2
3/4"
E
003
3/4"
12"-GC-247038-PJG(0.4)
DO NOT POCKET
5242963
C-2
MIN
FROM V-24707
247.009
3"
3"
5134289
C-2
12376
H
38
3"
SP
001
3/4"
CO2
ET 25
H
?
C-1
3/4"
SIZE:
DESIGN PR. & TEMP:
MATERIAL(VESSEL/INTERNALS):
INSULATION TYPE/THK:
TRIM:
RATED DUTY:
SURFACE AREA:
TEMA TYPE:
DESIGN PRESS:
DESIGN TEMP:
MATERIAL:
INSULATION TYPE / THK:
TRIM:
PJG(0.4) PJB(0.4)
TV
002B
3"x1-1/2"
1-1/2"
1-1/2"
?
C-1
FO
C-1
TO ATMOSPHERE
AT SAFE LOCATION
?
C-1
SHELL
350 kPa-g / HV
230C / 150C
CS + 3 mm 316 CLAD
H
KP-248029-PJB(0.4)
DESIGN PRESS:
DESIGN TEMP:
MATERIAL:
INSULATION TYPE / THK:
TRIM:
FO
C-1
3"
E-24801
?
C-1
RICH TEG
ET 10
38
3"-KP-248005-PJB(0.4)
TWO PHASE FLOW
3"
H
TC
002
2"
S-24801
H
ET 10
2"
2"
2"-SS-248002-SAG
?
C-2
LG
008
E-24802
MAG
V
5115277
C-1
1"
?
C-3
2"
1"-SS-248003-SAG
?
C-2
V-24806
2"
5134289
C-2
?
C-2
3/4"
5119160
C-2
3/4"
?
C-1
12425
NC
5069816
C-1
07/11/11
04/20/11
03/01/11
01/10/11
12/02/10
LT
004
LC
004
LC SIGNAL
12328
248.003
REV
ISSUED
DATE
DESCRIPTION
5115277
C-2
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
TO LV-004
TI
003
?
C-2
5134289
C-2
3/4"
7000 mm MIN.
?
C-2
NLL=690 mm
3/4"
5115277
C-2
1"
C-1
2"
11 Jul 2011
2"
LLL=260 mm
SHELL CANADA
TT
003
1-1/2"
6"x3"
2"
ET 10
38
LEAN TEG
3"-KP-248008-PJB(0.4)
12386
248.003
TO E-24803
?
C-2
?
C-1
?
C-1
2"x1"
2"x1"
FT
001
246.030
GI
MAG
2"
FC
C-1
?
C-1
2"
?
C-2
?
C-2
248.0000.000.041.002
REV.
248.002
2"
2"x1"
2"
2"
12427
1"
2"x1"
5115277
C-2
246.020
ET 10
38
3/4"
3
HP CONDENSATE
LV
003
2"
FREE DRAINING
2"
2"
HLL=1120 mm
3/4"
2"-SCH-248002-SAG
2"-SCH-248001-SAG
LG
004
LLLL=150 mm
SO
?
C-2
3/4"
V-24805
8"
HH
LG
003
FC
C-1 1"
?
C-1
2"
2"-GI-246018-ULB
?
C-2
MIN
LT
003
2"x1"
PCV
009
5115277
C-2
3/4"
5115277
C-2
3/4"
H
HLL=880 mm
1"
2"x1"
LLL=290 mm
?
C-2
MAG
2"
PT
008
FV
001
2"
NLL=700 mm
2"
?
C-2
?
C-2
HHLL=1000 mm
2"
2"
2"
5097550
C-2
2"
V
5134289
C-2
2"
2"
3/4"
CSO
C-1
?
FC
001
5134289
C-2
SAB SAG
LL
TT
001
3/4"
3/4"
2"
PI
008
ULB
001
24" MW
PJB(0.4)
LTE
010
2"x3/4" 3/4"
PI
016
PT
016
?
C-2
2"
?
C-2
002
C-1
E
PTE
004
2"x3/4" 3/4"
ET 10
38
ET 10
38
RV
001
HH
5134289
C-2
2"
2"
ET 10
38
2"-VA-248004-SAB
FIRE
1D2
SET@
5170 kPa-g
5134289
C-2
2"
?
C-1
2"x1"
2"
LC
003
10"
?
C-2
FROM E-24803
CSC
5062543
C-1
N/A
ET 10
12385
1"
TO ATMOSPHERE
AT SAFE LOCATION
248.003
8"
HH
3/4"
FC
C-1
3"-KP-248023-PJB(0.4)
TWO PHASE FLOW
MIN. 10D
4"
3/4"
?
C-1
FROM HEADER
RICH TEG
ET 10
38
4"x3"
1"
2"x1"
2"
5115277
C-2
H
50
2"-SS-248001-SAG
TYE
001
TV
001
3/4"
246.101
12545
8"
HH
TC
001
TO V-24803
?
C-3
FT
004
LOW TEMP HP STEAM
248.003
12380
2"
TT
002
V-24802
HOLDS:
ET 10
38
PJG(0.4) PJB(0.4)
1-1/2" 1-1/2" 3"x1-1/2"
3"x1-1/2" 1-1/2"
E
002
SCH-248006-SAG
ET 10
38
TV
002A
?
C-1
FI
004
TUBE
5170 kPa-g / FV
415C / 415C
316L SS
3"-KP-248002-PJG(0.4)
TWO PHASE FLOW
TUBE
350 kPa-g / HV
230C / 150C
316L SS + 0.38 mm CA
396 kW
8"
5134289
C-2
FROM V-24801
ET 10
38
SHELL
1400 kPa-g / FV
105C / 105C
CS + 3 mm 316 CLAD
H
KP-248028-PJB(0.4)
RATED DUTY:
SURFACE AREA:
TEMA TYPE:
8"-VA-248003-PJB(0.4)
3/4"
248.001
12379
3"-KP-248003-PJG(0.4)
RICH TEG
92 kW
3"-KP-248004-PJB(0.4)
TWO PHASE FLOW
ET 10
38
1-1/2" 3"x1-1/2"
E-24802
TEG STRIPPER REBOILER
?
C-2
E-24801
TEG STRIPPER CONDENSER
S-24801
TEG REGENERATION PACKAGE
5134289
C-2
SIZE:
DESIGN PR. & TEMP:
MATERIAL(VESSEL/INTERNALS):
INSULATION TYPE/THK:
TRIM:
V-24806
TEG SURGE DRUM
V-24802
TEG STRIPPER
3/4"
V-24805
TEG STRIPPER REBOILER CONDENSATE POT
V-24803
TEG FLASH DRUM
SIZE:
DESIGN PR. & TEMP:
MATERIAL(VESSEL/INTERNALS):
INSULATION TYPE/THK:
TRIM:
E-24803
LEAN/RICH TEG EXCHANGER
RATED DUTY:
SURFACE AREA:
DESIGN PRESS:
DESIGN TEMP:
MATERIAL:
INSULATION TYPE/THK:
TRIM:
TEMA TYPE:
0.6 MW
HOT
400 kPa-g / HV
230 C / 150 C
PLATES: 304L SS
FRAME: CS
/
KP-248031-PJB(0.4)
COMPABLOC
COLD
520 kPa-g / FV
210 C / 210 C
/
HOLDS:
TI
006
E-24803
LEAN TEG
12386
248.002
3"
FROM V-24806
RICH TEG
248.002
12385
TO V-24802
TT
006
ET 10
38
3"-KP-248008-PJB(0.4)
ET 10
38
3"-KP-248023-PJB(0.4)
6"x3"
3"
6"x3"
1-1/2"
6"x3"
3"
6"x3"
ET 10
38
LEAN TEG
3"-KP-248009-PAB
3"
1-1/2"
12378
248.004
TO P-24801A/B
PJB(0.4) PAB
TT
005
PC
005
TI
005
PT
005
12367
TO V-24701
3"-GC-248004-PJB(0.4)
DO NOT POCKET
3"
5242893
C-1
3/4"
H
25
3"x1" 1"
TO ATMOSPHERE
AT SAFE LOCATION
2"
FO
C-1
2"x1"
?
C-1
D
1"
5134289
C-2
247.001
3/4"
FLASHED CO2
PV
005
?
C-2
RV
002
NC
5096787
C-1
N/A
ET 10
8"-VA-248005-PJB(0.4)
8"x6"
C-1
3/4"
24"
MW
CSO
5242525
C-1
10"
2"
3/4"
8"
2"
2"-KP-247002-PJB(0.4)
TWO PHASE FLOW NNF
FROM V-24708
V-24803
?
2" C-2
HHLL=1100 mm
HLL=750 mm
NLL=710 mm
5063244
C-2
LLL=350 mm
2"-KP-248022-PAB
INTERMITTENT
LG
005
LI
005
LT
005
MAG
LLLL=250 mm
2"
MAKE-UP TEG
ET 10
38
TT
004
?
C-1
FC
C-1
?
C-1
3"-KP-248007-PJB(0.4)
04/20/11
03/01/11
01/10/11
12/02/10
B
REV
ISSUED
DATE
DESCRIPTION
S-3
TI
004
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
?
C-1
?
C-1
1-1/2"
07/11/11
ET 10
38
3"x1-1/2" 1-1/2"
3/4" 3/4"
ET 10
38
5134289
C-2
3"-KP-248006-PJB(0.4)
3/4"
6"x3"
6"x3"
3/4" 3/4"
?
C-2
2"
3"
?
C-2
LV
004
3/4" 3/4"
3/4"
248.002
5134289
C-2
?
C-2
3/4"
MIN
LC SIGNAL
FROM LC-004
L
HH
2"
12328
11 Jul 2011
?
C-2
?
C-2
12831
004
SO
248.005
SHELL CANADA
5
SP
002
A
R
248.0000.000.041.003
REV.
248.003
247.009
PAB
12373
ET 10
38
PJB(0.4)
KO TEG
MIN 10D
4"
5134289
C-2
FROM E-24801
TO GRADE WITHIN
TEG CONTAINMENT AREA
2"-GC-248003-PJB(0.4)
248.002
4"x3"
ET 10
38
?
C-3
12380
3"-KP-248005-PJB(0.4)
3/4"
2"
RICH TEG
8"-GC-248005-PJB(0.4)
8"
V
5134289
C-1
3
V-24808
LEAN TEG POST FILTER
SIZE:
RATED FLOW:
DESIGN PR. &TEMP:
PRESSURE DROP (CLEAN/DIRTY):
MATERIAL:
INSULATION TYPE/THK:
TRIM:
PARTICLE RETENTION SIZE:
2
V-24804A /B
LEAN TEG FILTER
V-24807
LEAN TEG CARBON FILTER
SIZE:
RATED FLOW:
DESIGN PR. &TEMP:
PRESSURE DROP (CLEAN/DIRTY):
MATERIAL:
INSULATION TYPE/THK:
TRIM:
mm ID x mm T/T x
1 m^3/hr
7200 kPa-g @ 210 C / HV @ 150C
/
304L SS + 0.4 mm CA
/
7
KP-248035-PAN
5 MICRONS
SIZE:
RATED FLOW:
DESIGN PR. &TEMP:
PRESSURE DROP (CLEAN/DIRTY):
MATERIAL:
INSULATION TYPE/THK:
TRIM:
mm ID x mm T/T x
1 m^3/hr
7200 kPa-g @ 210 C / HV @ 150C
/
304L SS + 0.4 mm CA
/
7
KP-248034-PAN
mm ID x mm T/T x
6 m^3/hr
7200 kPa-g @ 210 C / HV @ 150C
/
304L SS + 0.4 mm CA
/
7
KP-248032-PAN
KP-248033-PAN
5 MICRONS
PDI
007
HOLDS:
PI
003
PDT
007
2"
2"
?
C-2
NC
?
C-2
3/4" 3/4"
?
C-2
3/4" 3/4"
ET 10
38
2"-KP-248014-PAN
2"-KP-248015-PAN
?
C-1
3/4" 3/4"
3/4"
5115273
C-2
?
C-2
2"
RS
V-24804B
NC
?
C-2
V-24807
?
C-2
RS
2"
1"
5115273
C-2
1"
D
2"
3/4"-KP-248039-PAN
V-24808
5115273
C-2
2"-KP-248019-PAN
TO SAFE LOCATION
3/4"
RS
3/4"
RS
1"-VA-248011-PAB
2"
3/4" 3/4"
5115273
C-2
3/4" 3/4"
?
C-2
3/4" 3/4"
5115273
C-2
?
C-2
3/4"
RS
RV
008
C-1
FT
005
TO SAFE
LOCATION
FIRE
3/4"x1"
3/4
SET@
7200 kPa-g
PAB PAN
5115273
C-2
RS
5115273
C-2
?
C-2
3/4"
2"
5115273
C-2
3/4" 3/4"
FC
005
3/4"
PDT
015
FX
005
2"-KP-248017-PAN
FIRE
3/4
3/4"x1"
SET@
7200 kPa-g
RV
PAN PAB
009
2"
ET 10
38
?
C-2
V-24804A
2"-KP-248018-PAN
PDC
015
C-1
1-1/2"
NC
5062541
C-1
2"
RS
5115273
C-2
5115273
C-2
?
C-2
?
C-1
1"-VA-248009-PAB
ET 10
38
PDT
016
2"-KP-248020-PAN
2"
?
C-2
5115273 3/4"-KP-248044-PAN
C-2
?
C-1
3/4" 3/4"
PDC
016
FO
C-1
2"x1"
TO SAFE LOCATION
3/4"-KP-248038-PAN
2"
RS
3/4"
?
C-1
TO E-24804
1"
2"x1"
3/4" 3/4"
2"
3/4"
ET 10
63
3/4"
248.001
12616
?
C-2
LEAN TEG
5115273
C-2
2"-KP-248016-PAN
?
C-2
C-1
PT
003
?
C-2
1"-VA-248010-PAB
FV
005
FIRE
3/4
3/4"x1"
SET@
7200 kPa-g
RV
007
?
C-2
PAB PAN
SP
004
S-9
6
3/4"
D
5115273
C-1
3/4"
C-1
PG
012
RV
005
C-1
5063244
C-1
BLOCKED
DISCHARGE
1D2
SET@
7200 kPa-g
PG
013
07/11/11
04/20/11
03/01/11
01/10/11
12/02/10
2"-KP-248043-PAN
3/4" 3/4"
?
C-2
HOA
E
01
?
C-2
3/4" 3/4"
PAB
PAN
5115273
C-1
5115273
C-1 3/4"
3/4"
?
C-1
01
HIS
005
R/S
SP
003B
P-24801A
MC
PDP
APE
PEM CLIENT
APP
01
SHELL CANADA
QUEST CCS PROJECT
VFD
P-24801A /B
LEAN TEG PUMPS
MATERIAL:
INSULATION TYPE/THK:
TRIM:
CS
R/S
P-24801B
VFD
6.2 m^3/hr
5742 kPa
10.0 kW
CASING
INTERNALS
CS
CS
/
KP-248037-PAN
KP-248036-PAN
HIS
006
3"-KP-248011-PAN
RATED FLOW:
DIFF. PR.:
DRIVER:
PRS
HS
006A
E
01
CKD
3"
?
C-1
BY
HOA
?
C-2
3"
?
C-2
HS
005A
3"-KP-248010-PAN
DESCRIPTION
3/4" 3/4"
?
C-2
?
C-2
SP
003A
PP
3/4" 3/4"
PP
ISSUED
DATE
1"-KP-248042-PAN
PP
5115273
C-1
3/4"
PP
REV
5115273
C-1
2"-KP-248041-PAN
1"-KP-248040-PAN
XA
002
XL
002
VFD
LOCAL/
FAULT REMOTE
XA
001
XL
001
VFD
LOCAL/
FAULT REMOTE
SI
001
HIC
012
HS
007
PUMP DUTY
SELECTOR
SI
002
R
248.0000.000.041.004
REV.
RV
003
ET 10
38
2"-KP-248013-PAN
BLOCKED
DISCHARGE
1D2
SET@
7200 kPa-g
2"-KP-248012-PAN
5063244
C-1
D
5115273
C-1
248.004
FROM E-24803
?
C-1
2"
2"
ET 10
38
3"-KP-248009-PAB
3/4"
248.003
PAB
PAN
12378
?
C-1
LEAN TEG
ET 10
38
ET 10
38
S- 24802
TEG MAKE-UP PACKAGE
HOLDS:
NUMBER OF RVs AND SIZING TO BE CONFIRMED DURING DETAILED ENGINEERING.
INSTRUMENT SIZING TO BE CONFIRMED DURING DETAILED ENGINEERING.
3/4"-VA-248007-PAB
?
?
1" HOSE
SP
005
?
?
1"-VA-248006-PAB
INSIDE OUTSIDE
SET@
530 kPa-g
RV
006
1000L
TOTE TANK
(REMOVABLE)
(BY SHELL)
3/4" 3/4"
2"x1"
2"
I
02
?
?
2"
?
?
SP
006
2"
C-1
C-1
INSIDE
N/A
OUTSIDE
ET 10
ET 10
38
MAKE-UP TEG
2"-KP-248022-PAB
12831
248.003
TO V-24803
PG
010
LI
011
2"
L
C-2
1" HOSE
PI
011
PT
011
C-1
C-2
1-1/2"x3/4"
2"x1"
6" FILL CAP
2"x1"
2" HOSE
3/4"
2"
1000 L
TOTE TANK
(OPERATING)
X2
LG
009
PP
C-2
2"
MAG
3/4" 3/4"
C-2
2" HOSE
2"
004
2"
D
D
I
002
HIS
008
P-24802
07/11/11
04/20/11
03/01/11
01/10/11
12/02/10
B
REV
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
CURB
SHELL CANADA
QUEST CCS PROJECT
A
R
P-24802
TEG MAKE-UP PUMP
RATED FLOW:
DIFF. PR.:
DRIVER:
MATERIAL:
INSULATION TYPE/THK:
TRIM:
620 L/hr
380 kPa
1.00 kW
CASING
CS
/
INTERNALS
CS
SCALE: NONE
SHELL DWG NO.:
248.0000.000.041.005
REV.
CURB
R/S
C-1
3/4"
C-1
3/4"
HS
008A
11 Jul 2011
2"
3/4"
3/4"
2"
2"
HOA
E
C-2
LT
011
1-1/2"x3/4"
LG
011
248.005
1"-VA-248008-PAB
2"
3/4"
S-24802
C-2
2"x1"
E-44014
WASH WATER MAKE-UP COOLER
RATED DUTY:
SURFACE AREA:
TEMA TYPE:
0.7 MW (TOTAL)
31.8 m^2
BEU
4
SHELL
TUBE
4025 kPa-g / FV
DESIGN PRESS: 3100 kPa-g /
150 C / 150 C
DESIGN TEMP: 58 C /
CS + 0.38 mm CA
MATERIAL: CS + 3 mm CA
3
/
/ 3
INSULATION TYPE/THK:
TRIM: PROCESS SIDE: WB-440012-SAD
COOLING WATER SIDE: CWS-440077-SAD
D
441
FC
076
HH
E
453
FYE
076
FO
FT
076
2"x1-1/2"
ET 10
38
1-1/2"
2"x1-1/2"
?
?
?
?
FROM HEADER
D
3/4"
5115277
?
3/4"
1"
?
?
1-1/2"
1-1/2"
5115277
?
2"x1-1/2"
5115277
?
440.021
2"
2"-WB-440010-SAG
3/4"
FV
076
FC
2"x1-1/2"
?
?
TW
010
1"
CSC 5062543
?
6"-CWR-441045-UAB
ET 10
38
3"
8"x3"
8"-CWR-440045-UAB
440.012
CSO
?
?
12722
FROM E-44129
1-1/2"
SAG SAD
441.031
TO HEADER
3/4"
TW
008
1-1/2"
V
5115277
?
C
RS
C
UAB
SAD
E-44014
SAD
UAB
RS
TI
009
TT
009
4
1-1/2"
?
?
WASH WATER
12113
441.030
TO V-44119
3"
3"
2"-WB-440011-SAD
5115277
?
3/4"
ET 10
38
ET 10
38
8"x3"
440.012
?
?
FROM HEADER
BACK FLUSH
12721
441.031
TO E-44129
11 Jul 2011
07/11/11
04/20/11
03/01/11
01/10/11
12/02/10
REV
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
SHELL CANADA
QUEST CCS PROJECT
A
R
SCALE: NONE
SHELL DWG NO.:
440.0000.000.041.048
REV.
440.048
12983
TO UC-246002
I
104
HH
3/4" 3/4"
PAC
HJE(0.4)
5
S-4
SP.
4"-P-441097-HJE(0.4)
050
16"-P-441096-HJE(0.4)
485.213
14"-P-441101-DAG
11
ET 10
10"
3/4"
FROM P-24602A/B/C
TO V-44119
HOLDS:
NUMBER OF RVs AND SIZING TO BE CONFIRMED DURING DETAILED ENGINEERING.
INSTRUMENT SIZING TO BE CONFIRMED DURING DETAILED ENGINEERING.
CONFIRM AVAILABILITY OF DCS AND SIS INTERLOCK SEQUENCE NUMBERS ADDED
FOR QUEST.
14"-P-441102-DAE
1-1/2"
M
441.030
16"
FV
075
FO
14"-P-441103-DJE(0.4)
14"x10" FC 14"x10"
3/4"
LEAN AMINE
FT
075
12074
FYE
075
TT
030
H2 RAW GAS
V
6"
TI
030
E
451
18"x14"
36"
MW
18"
MIN
DAE DJE(0.4)
D
10"
CSC
DAG DAE
3"
PDT
064
3/4"
FC
075
246.002
FROM LX-246001
12072
12777
FREE DRAINING
SET POINT
12405
FREE DRAINING
CSO
440.049
FL
6"-FL-441035-PAC
3/4" 3/4"
6"x3"
ET 10 FREE DRAINING
3/4"
B
V
3/4"
CSC
RV
023
FIRE
1-1/2H3
SET@
kPa-g
CSO
V-44118
AMINE ABSORBER 3
4"x1-1/2"
V-44118
3"
25
PDI
064
E
450
E
453
HZTE
015
I
104
I
103
HYE
015
ET 35
88
10
I
102
FO
20"-P-441095-HJE(0.4)
HIC
015
12"
20"x12"
20"-P-441095-HJE(0.4)
FO 20"x12"
HIC
014
BYPASS
H2 RAW GAS
441.030
12110
TO HMU 3 PSA
HV
015
E
453
E
450
1
24"
MW
2"
HHLL=4000 mm
7
24"
MW
NLL=2550 mm
LLL=1800 mm
2"
3"
LG
155
3/4"
3/4"
3"
3/4"
4500 mm
3/4"
03/01/11
01/10/11
12/02/10
ISSUED
DATE
DESCRIPTION
20"
D
3/4"
20"x12"
XV
020
10"
10"-P-441104-DJE(0.4)
12"x10"
4"
3/4"
FO
TT
031
8"
1-1/2"
10"x8"
FC
FC
LV
155
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
11
ET 10
10"x8"
SP
052
SHELL CANADA
10"-P-441104-DJE(0.4)
SP
053
RICH AMINE
485.213
TO E-24602A/B
8
S-9
VACUUM TRUCK
CKD
12076
4"-P-441106-DJE(0.4)
BY
441.0000.000.041.029
REV.
441.029
2"-P-441105-DJE(0.4)
3/4"
12723
1"-SCL-441XXX-SAB
04/20/11
TI
031
A/S
4"
440.018
SCL
XYE
020
s
XZTE
020
1"-SL-441XXX-SAB
XZI
020
450
3"
LLLL=300 mm
SO
N/A
ET 10
06/13/11
REV
2"
12724
LI
155B
LT
155B
3
3"-SL-440XXX-SAB
LC
155
2"x3/4"
440.018
SL
LHS
155
MAG
2"
3"
SWING
ELBOW
3/4"
LI
155A
LT
155A
HLL=3300 mm
2"
14
DP
HJE(0.4)
ULB
SWING
ELBOW
2"
2"
3"
3/4"
13014
2"
2"
3"
3/4"
V
2"-GI-440072-ULB
START-UP
LL
3/4"
440.046
GI
GWR
LTE
154
3/4"
CSC
PP
MIN
HH
3/4" 3/4"
MIN
E
450
24"
3/4"
E
451
24"x20"
3/4"
20"x16" FC 20"x16"
MIN
HV
014
FROM HMU 3
051
3/4"
441.016
12
2"
12077
ET 35
20"-P-441094-HJE(0.4)
88
3/4"
H2 RAW GAS
SP.
16"
3"
3"
FO
HZTE
014
3/4"
I
102
3/4"
10
HYE
014
1
FI
074B
V-44119
ABSORBER 3 WASH WATER VESSEL
SIZE:
DESIGN PR. & TEMP:
MATERIAL(VESSEL/INTERNALS):
INSULATION TYPE/THK:
TRIM:
FC SIGNAL
FX
074B
441.016
FROM HMU 3
ET 35
88
20"-P-441095-HJE(0.4)
443.003
HOLDS:
BYPASS
PC
067
AI
016
3/4"
6" 10"x6"
FC
TSO
10"-FL-441036-PAC
FREE DRAINING
440.049
FL
PI
065
PT
065
XV
019
20"x16"
INST
PIPING
FLOW
AP
016A
TT
032
FT
074
20"-P-441098-HJE(0.4)
1-1/2"
H2 RAW GAS
ET 35
88
FC
12111
441.016
TO HMU 3 PSA
DETAIL "B"
2"
3/4"
3/4"
3/4"
AP
016B
FO
16"
12912
AP
016C
A/S
XZTE
019
440.049
FL
3/4" 3/4"
INST
PIPING
XYE
019
3/4" 3/4"
FREE DRAINING
AE
016
E
453
3"
16"
CSC
3"
3"
CO2 RICH
DETAIL "B"
E
450
PT
067
TI
032
AIT
016
CO2 LEAN
12775
PAC
HJE(0.4)
ET 38
88
6"-P-441099-HJE(0.4)
ET 10
FREE DRAINING
I
101
HOLD
PV
067
CO2
3/4" 3/4"
441.029
12864
FX
074A
3/4" 3/4"
12110
SET POINT
FHS
074
f(x)
H2 RAW GAS
12714
FROM FC-377
FI
074A
24"
MW
440.048
3"
3"x2"
2"-WB-440011-SAD
MIN
FROM E-44014
24"
MW
V-44119
9
SAD HJE(0.4)
HJE(0.4) PJE(0.4)
7
6"
24"
MW
6"x4"
ET 10
4"-P-441113-PJE(0.4)
CIRCULATING WATER
441.031
FROM E-44129
3"
E
452
3/4"
3/4"
2"
DP
HH
6
LL
2"
LTE
159
2"
LG
157
24"
MW
HLL=2380 mm
2"
2"
NLL=1070 mm
5
3"
3"
LLL=910 mm
3"
DP
LI
157A
06/13/11
04/20/11
03/01/11
01/10/11
12/02/10
LI
157B
LC SIGNAL
LHS
157A
12416
441.031
REV
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
TO LC-157
3/4"
2"
3"
LT
157A
LT
157B
3/4"
2"
HHLL=2550 mm
3"
MAG
L
E
453
3"
3/4"
3"
2"
3/4"
LI
159
2"
3/4"
3"
3/4"
LI
156
3/4"
FREE DRAINING
FROM V-44118
3"
18"
3/4"
441.029
18"x16"
16"-P-441096-HJE(0.4)
3/4"
12074
PP
3/4"
H2 RAW GAS
GWR
3/4" 3/4"
LTE
156
12415
LLLL=300 mm
SO
SHELL CANADA
7860 mm
8"
8"x6"
ET 10
6"-P-441107-PJE(0.4)
CIRCULATING WATER
12414
441.031
3"
TO P-44108A/B
D
R
441.0000.000.041.030
REV.
441.030
12113
WASH WATER
PDI
066
PDT
066
E-44129
ABSORBER 3 CIRCULATING WATER COOLER
0.3 MW
49.3 m^2
BEU
SHELL
3800 kPa-g / HV
60 C / 150 C
CS + 3 mm 304L SS CLAD
/
6
P-441122-PJE(0.4)
RATED DUTY:
SURFACE AREA:
TEMA TYPE:
DESIGN PRESS:
DESIGN TEMP:
MATERIAL:
INSULATION TYPE/THK:
TRIM:
TUBE
2950 kPa-g /
58 C /
SUPER DUPLEX 2507 + 0.38 mm CA
/
6
CWR-441XXX-PJE(0.4)
D
HOLDS:
LC
157
441.030
LHS
157B
LV
157A
FROM LHS-157A
2"x1"
1"
3/4"
FC
2"x1"
3/4"
FC
SP
054
3/4"
FO
XZTE
018
ET 10
50
6"-P-441107-PJE(0.4)
FC
6"x4"
1-1/2"
3/4"
6"x4"
I
103
TO V-44119
6"x4"
1-1/2"
4"x3"
6"x4"
4"x3"
440.048
RS
UAB
PJE(0.4)
E-44129
PJE(0.4)
UAB
ET 10
50
4"-P-441113-PJE(0.4)
6"-CWS-440076-UAB
12721
FROM HEADER
4"
D
BACK FLUSH
SEL
ET 10
50
HS
SI
3/4"
D
PP
TO
GRADE
PP
SP
055
3/4"
P-44108A
XL
017
VFD
FAULT
LOCAL/
REMOTE
SI
06/13/11
04/20/11
03/01/11
01/10/11
12/02/10
3/4"
REV
ISSUED
DATE
DESCRIPTION
BY
CKD
PRS
CS
MC
PDP
APE
PEM CLIENT
APP
D
PP
TO
GRADE
PP
SP
055
3/4"
3/4
"
D
3/4"
3/4"
3/4"
D
D
VFD
MIN.
VFD
E
452
XA
017
HOA
3/4"
D
D
P-44108B
3/4
"
D
SHELL CANADA
QUEST CCS PROJECT
A
R
P-44108A /B 7
ABSORBER 3 CIRCULATING WATER WASH PUMPS
RATED FLOW:
DIFF. PR.:
DRIVER:
MATERIAL:
INSULATION TYPE/THK:
TRIM:
56.5 m^3/hr
233 kPa
5.6 kW
CASING
INTERNALS
316 SS
316 SS
/
6
P-441123-PJE(0.4)
441.0000.000.041.031
REV.
LOCAL/
REMOTE
3/4"
HS
017A
MIN.
XL
016
I
100
4"-P-441111-PJE(0.4)
VFD
FAULT
R/S
3/4"
E
452
XA
016
HIS
017
ET 10
50
3/4"
HOA
6"-P-441109-PJE(0.4)
HS
016A
ET
I
100
ET 10
50
R/S
ET 10
HIS
016
4"-P-441110-PJE(0.4)
12415
ET 10
38
6"-P-441108-PJE(0.4)
441.030
4"-P-441113-PJE(0.4)
12722
CSO
FT
077
3/4"
CIRCULATING WATER
LL
RS
TG
033
6"-CWR-441045-UAB
TO HEADER
4"-P-441XXX-PJE(0.4)
FC
077
ET 10
50
4"-P-441112-PJE(0.4)
NC
FROM V-44119
1-1/2"
441.031
441.030
XV
018
TG
034
ET 10
12414
TW
035
3/4"
CIRCULATING WATER
PT
070
S-8
A/S
441.013
TO V-44111
PI
070
3/4"
PURGE WATER
2"x1"
3/4" 3/4"
XYE
018
2"x1" 1"
2"-P-441115-PJE(0.4)
XZI
018
2"-P-441116-PJE(0.4)
3/4"
LV
157B
E
452
ET 10
38
ET
12416
2"
LC SIGNAL