Professional Documents
Culture Documents
Shear Wall UBC and ACI Design Guide
Shear Wall UBC and ACI Design Guide
WT
INTRODUCTION
IR. WIRA TJONG, MSCE, SE
Area of Expertise
Codes Requirements and Applications
Seismic Design for New Buildings/Bridges and Retrofit
Modeling and Software Development
Biotechnology and Microelectronic Facilities
California School and Hospitals
WT
DEFINITION
SHEAR DESIGN
WT
DEFINITION
SHEAR WALL IS A STRUCTURAL ELEMENT USED TO
RESIST LATERAL/HORIZONTAL/SHEAR FORCES
PARALLEL TO THE PLANE OF THE WALL BY:
WT
WALL REINFORCEMENT
MINIMUM TWO CURTAINS OF WALL REINFORCEMENT SHALL BE PROVIDED IF
Vu > 2 Acv(f'c)1/2 [0.166 Acv(f'c)1/2 ]
OR
Lw
2 LAYERS IF T> 10" OR
Vu > CONCRETE SHEAR
CAPACITY
Av > Ah FOR
Hw/Lw < 2.0
Hw
WT
WALL REINFORCEMENT
0.0025
[0.083 Acv(fc)1/2 ]
WT
SHEAR DESIGN
Vn > Vu
A. SHEAR DEMAND
WT
SHEAR DESIGN
B. SHEAR STRENGTH
NOMINAL SHEAR STRENGTH
Vn = Acv [2(fc)1/2 + nfy]
Acv [0.166(fc)1/2 + nfy]
Hw
Lw
SEGMENT
1
SEGMENT
2
Hw/Lw SHALL BE TAKEN AS THE LARGEST RATIO FOR ENTIRE WALL OR SEGMENT OF
WALL
WT
SHEAR DESIGN
STRENGTH REDUCTION FACTOR FOR WALLS THAT WILL FAIL IN SHEAR INSTEAD OF
BENDING
=0.6
=0.6
OTHERWISE
=0.85
WT
0.70
OR
TENSION
10
WT
11
WT
WALLS WITH HIGH AXIAL LOAD SHALL NOT BE USED AS LATERAL RESISTING
ELEMENTS FOR EARTHQUAKE FORCE IF
Pu > 0.35 Po
WHERE
Po = 0.8[0.85fc'(Ag - Ast) + fy Ast]
12
WT
PER UBC :
a. Pu <= 0.10Agfc FOR SYMMETRICAL WALL
Pu <= 0.05Agfc FOR UNSYMMETRICAL WALL
AND EITHER
b. Mu/(VuLw) < = 1.0 (SHORT/SQUAT WALL OR
Hw/Lw < 1.0 FOR ONE STORY WALL)
OR
c. Vu <= 3 Acv (fc)1/2 [0.25 Acv (fc)1/2 ]
AND
PER ACI :
THE FACTORED AXIAL STRESS ON LINEAR ELASTIC GROSS SECTION < 0.2 fc
13
WT
0.15Lw
Lw
BZ
> 0.15 Lw
14
WT
BOUNDARY ZONE DETAIL SHALL BE PROVIDED OVER THE PORTION OF WALL WITH
COMPRESSIVE STRAIN > 0.003.
TENSION
COMPRESSION
u = t C 'u
0 .0 0 3
C'u
LENGTH OF
BOUNDARY
MEMBER
Lw
15
WT
16
WT
17
WT
CALCULATE YIELD DEFLECTION AT THE TOP OF WALL CORRESPONDING TO A COMPRESSIVE STRAIN OF 0.003
y = (Mn'/Me)e
18
WT
19
WT
y = 0.003/Lw
THE COMPRESSIVE STRAIN ALONG COMPRESSIVE BLOCK IN THE WALL MAY BE ASSUMED VARY LINEARLY OVER
THE DEPTH Cu' WITH A MAXIMUM VALUE EQUAL TO
cmax = (Cu' X t)
THE COMPRESSIVE BLOCK LENGTH Cu CAN BE DETERMINED USING STRAIN COMPATIBILITY AND REINFORCED
CONCRETE SECTION ANALYSIS.
20
WT
DIMENSIONAL REQUIREMENTS
ND
ST
FL
BZ
>lu/16
Ld of
Vert. Bar
FL
GROUND Fl
Vertical Extent of
Bound. Reinf.
Lu
BZ
> Lw
> M u/4Vu
Ec =0.003
B Z
>18" (46cm)
21
WT
CONFINEMENT REINFORCEMENT
L
BZ
6 d b (> 3 in )
(>75 mm)
6d
extension
Notes:
b
x/
hx
y
x
BZ
Alternate Vertical
Bars Shall Be
Confined
x
As > 0.005 L
minimum
4 -# 5(DIA 16 mm)
BZ
BZ
with
1. Per UBC:
'x' or 'y' < 12 inches (30 cm)
Per - ACI
' hx' < 14 inches (35 cm)
2. Hoop dimensional ratio
(3x/2y) or (2y/3x) <3
3. Adjacent hoops shall be
overlapping
4. Per ACI:
Sv < Tbz / 4
Sv < 4 +[(14-hx)/3]
in inches
< 10 + [(35-hx)/3]
in cm
22
WT
23
WT
Tsi = As fy
si < y :
Tsi = As fs WHERE fs = Es s
TENSION
COMPRESSION
S3
S2
S7
S5
S4
S6
STEEL STRAIN
c = 0.003
C'u
S1
CONCRETE
STRAIN
24
WT
FORCE EQUILIBRIUM
Pu + Tsi + Csi + Cc = 0
WHERE
Pu = 1.2 D + 0.5 L + E
AND
Cc= 0.85 fc B Cu
MOMENT EQUILIBRIUM
Mn = Tsi X esi + Csi X esi + Cc ec
SOLVE FOR Cu THAT SATISFIES THE ABOVE EQUILIBRIUM.
Center
Line
COMPRESSION
TENSION
B C'u
e
Cc
Pu
Lw
Cs7
C S6
TS5
TS4
TS3
TS2
0.85 f'c
STEEL FORCES
TS1
CONCRETE
STRESS
25
WT
SUMMARY
26