You are on page 1of 17

Kelas semen

p barite
p bentonite
p semen

A
4.33
2.65
3.14

semen(gr)

air (ml)

600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600

276
276
276
276
276
276
276
276
276
276
276
276
276
276
276
276

gr/cc
gr/cc
gr/cc
additive (gr)
barite
bentonite
0
0.75
1.5
2.25
3
0
0.75
1.5
2.25
3
3.75
4.5
5.25
6
6.75
7.5

vol air
vol semen

volume
additive (cc)

276

SG semen
gr/cc

cc
cc

SG semen
ppg

berat air
berat semen

600

gr
gr

Kelas Semen
WCR

A
46%

Semen (gram)

Air (ml)

600
600
600
600
600
600
600
600

276
276
276
276
276
276
276
276

Additive (gr)
Barite
Bentonite
0
2
4
6
0
2
4
6

C300

C600

135
172
187
202
172
162
154
130

155
217
237
262
242
227
217
177

p (cp)

Yp (lb/100ft2)

Semen
(gram)
600
600
600
600
600
600
600
600

Air (ml)
276
276
276
276
276
276
276
276

Additif (gram)
NaCl
CMC
0
1
2
3
0
1
2
3

Thickening
Time (uc)
14
16
22
23
15
14
10
8

Semen
(gram)
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600

Air (ml)
276
276
276
276
276
276
276
276
276
276
276
276
276
276
276
276

Additif (gram)
Bentonite
Barite
0
1
2
3
4
5
6
7
0
1
2
3
4
5
6
7

Free Water @ 2 jam


(ml)
0.5
0
0
0
0
0.75
0
0
0
0.25
0.1
0
0
0
0
0

Kelas Semen
WCR

A
46%

Semen
(gram)

Air (ml)

600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600

276
276
276
276
276
276
276
276
276
276
276
276
276
276
276
276

Additif (gram)
Bentonite
0
1
2
3
4
5
6
7

Kerosene

0
2
4
6
8
10
12
14

Filtration Loss @ Filtration Loss @ 30


30 menit percobaan Menit Perhitungan
(ml)
93
120
94
115.5
84.5
129
120
89
143.5
60.5
139.5
110.15
111.5
112.15
113
108.5

Faktor
Koreksi

Additif (gram)

Semen
(gram)

Air (ml)

600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600

276
276
276
276
276
276
276
276
276
276
276
276
276
276
276
276

Bentonite

NaCl

P (Pembebanan
Maksimum), psi

Diameter
bearing (in)

D (in)

1.5
2
2.5
3
3.5
4
4.5
6

257
250
249
242
235
231
229
226
140
149
150
170
182
202
220
224

6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5

0.96
1.01
1.06
1.11
1.16
1.21
1.26
1.31
0.96
1.01
1.06
1.11
1.16
1.21
1.26
1.31

0
0.5
1
1.5
2
2.5
3
3.5

f(x) =
R = 0

Chart Title
12.000
10.000
8.000

Axis Title

Column L

6.000

Linear (Column

4.000
2.000
0.000
0.000

5.000

Axis Title

10.000

15.000

r1 (in)

r2 (in)

3.25
3.25
3.25
3.25
3.25
3.25
3.25
3.25
3.25
3.25
3.25
3.25
3.25
3.25
3.25
3.25

t (in)

t/D

A1

A2

1.614
1.614
1.614
1.614
1.614
1.614
1.614
1.614
1.614
1.614
1.614
1.614
1.614
1.614
1.614
1.614
Rumus r2 = D/2

Grafik Hubungan Additive vs Compressive Str


12
10
8
Column L
Linear (Column L)

Compressive Strength (psi)

6
4
2
0

Additive (gr)

Compressive
Strength (Psi)

t/D

koefisien
faktor

1.75
1.5
1.25
1

0.98
0.96
0.93
0.87

tive vs Compressive Strength

Bentonite
NaCl

Additive (gr)

Additif (gram)

Semen
(gram)

Air (ml)

600
600
600
600
600
600
600
600
600
600
600
600
600
600
600
600

276
276
276
276
276
276
276
276
276
276
276
276
276
276
276
276

Bentonite

NaCl

P (Pembebanan
Maksimum), psi

Diameter
bearing (in)

d (in)

1.5
2
2.5
3
3.5
4
4.5
6

257
250
249
242
235
231
229
226
140
149
150
170
182
202
220
224

6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5

0.96
1.01
1.06
1.11
1.16
1.21
1.26
1.31
0.96
1.01
1.06
1.11
1.16
1.21
1.26
1.31

0
0.5
1
1.5
2
2.5
3
3.5

r1 (in)
3.25
3.25
3.25
3.25
3.25
3.25
3.25
3.25
3.25
3.25
3.25
3.25
3.25
3.25
3.25
3.25

A1 (in)

h (in)

t (in)

2.01
2.51
3.01
3.51
4.01
4.51
5.01
5.51
1.73
2.23
2.73
3.23
3.73
4.23
4.73
5.23

1.614
1.614
1.614
1.614
1.614
1.614
1.614
1.614
1.614
1.614
1.614
1.614
1.614
1.614
1.614
1.614

t/d

Shear Bond
Strength (psi)

Grafik Additive vs Shear Bond Strength


12.000
10.000
8.000

Shear Bond Strength (psi)

Bentonite

6.000

NaCl

4.000
2.000
0.000

Additive (gr)

ngth

Bentonite
NaCl

t/D

koefisien
faktor

1.75
1.5
1.25
1

0.98
0.96
0.93
0.87

@ 80 oF

0.04467 lb/ft.hour

@ 100 oF
468 Rn
500 Rn
semen
Tu
t
udara
udara
t
ops

0.04594 lb/ft.hour
0.55648
0.58233
1.377 gr/cc
27 C
12.14 detik

Rn

Visk
12
10
8

Temperature (oF)

6
4
2
0

Visk

oF)

Viskositas vs Temperatur
12
10
8
6

Viskositas vs Temperatur

4
2
0

Viskositas (lb/ft.hour)

10

12

You might also like