Symptom
Central Management Server does not start after applying BI 4.1 patch on top of BI 4.0 SP05 patch 12
Following Errors are captured in the Install logs,
l
ERROR: An unexpected internal error occurred. The CMS failed to start: CreateProcess error=14001, The application has failed to start
because its side-by-side configuration is incorrect. Please see the application event log or use the command-line sxstrace.exe tool for more
detail. (FWM 23026)
FollowingerrorisalsocapturedinEventViewer'sApplicationlog.
l
Activation context generation failed for "E:\APPS\BI4\SAP BusinessObjects Enterprise XI 4.0\win64_x64\SvcMgr.exe". Dependent
Assembly
Microsoft.VC80.CRT,processorArchitecture="amd64",publicKeyToken="1fc8b3b9a1e18e3b",type="win32",version="8.0.50727.6195"
could not be found. Please use sxstrace.exe for detailed diagnosis.
Environment
l
l
Cause
ThecorrectMicrosoftVisualC++2005distributablesarenotinstalled.
Resolution
1. UninstallSAPBusinessObjectsBI4.1patch.
2. Download and install the Microsoft Visual C++ 2005 Service Pack 1 Redistributable Package MFC Security Update x86 and x64
executables from http://www.microsoft.com/en-us/download/details.aspx?displaylang=en&id=26347.
3. Reinstall SAP BusinessObjects BI 4.1 patch.
See Also
1925761
Keywords
BI4.1,CMS,Activationcontextgenerationfailed
Header Data
Released On
Release Status
Component
Priority
Category
Database
27.11.2013 14:44:31
Released to Customer
BI-BIP-DEP SBOP Web Application Deployment, Wdeploy
Normal
Problem
MSSQLSRV 2008
Product
Product
Product Version
SAP BusinessObjects Business Intelligence platform SAP BusinessObjects Business Intelligence platform 4.1
References
This document refers to:
SAP Knowledge Base Articles
1925761 Error "side-by-side configuration incorrect" when starting the CCM and on the Crystal Reports and Dashboards Servers in the CMC