WSM W410, WSM W410X
MANUAL
FUNCTIONS
‘1 stpage: current wind speed
- current wind speed bar graph (setted max alarm level is always on % bar height)
- peak wind speed in last 2 minutes bar graph (setted max alarm level is always on % bar
height)
= temperature
= Max Alarm value
- Pre alarm 2 value
- unit of wind speed measurement
- signal strength value (in dB)
- received data package indicator
2nd page: 8 hours peak wind speed history graph with 5 minutes resolution, each row present peak wind
speed during 5 minutes
3th page: 8 hours Max. alarm history graph with 5 minutes resolution
‘Switching between pages:
‘With short presses of HIST key you can enter to page 2 and 3 to see the wind speed and max. alarm history.
Display will return on first page with 3 sec. press of HIST key or automatically after 1 minutes of inactivity.
OPERATION OF ALARMS
Pre alarm 1: when setted value is exceed the relay 1 will activate
Pre alarm 2: when setted value is exceed the relay 2 will activate, yellow light will start bli
sound with interrupted sound
1g and buzzer will
Max alarm: when setted value is exceed the relay 3 will activate, red light will flash and buzzer will continuously
sound.
‘When sound alarm is activated you can mute it by pressing upper key for 3 seconds.
SETTING OF PARAMETERS
1. Hold pressed the SET key to enter the setting menu. If the password protection is active, enter correct
password. The group of settings displays on display.
2. Select the group by using up and down keys and press SET key to enter into selected group.
3, By up and down keys select the parameter you wish to adjust and press SET key to enter into selected
parameter. The adjustable parameter blinks.
4, By up and down key adjust the parameter value, Press SET to enter new value and move to next
parameter.
5. Exiting setting menu: hold pressed the SET key to move back for one level
Anemometer also return to normal operation after 2 minutes of inactivity.SETTINGS
WSM W410 Settings
Max Alarm select to set Max Alarm parameters
Pre Alarm 2 select to set Pre Alarm 2 parameters
Pre Alarm 1 select to set Pre Alarm 1 parameters
General ‘select o set general parameters
Settings: Max Alarm
Factory _| Setting range: Description:
preset \
Wind Speed: | 72 km/h 4-80 mis Max Alarm limit
‘ON Delay: Os 0-600s Minimum time of exceed Wind speed to activate the Max
alarm
OFF Delay: Omin 0-60 min Delay of alarm switch OFF after wind speed drop below
preset level
Relay = Normal | NormaVinverted inverted operation of relay
Settings: Pre Alarm 2
Factory | Setting range Description:
preset:
Wind Speed: | §2 km/h | 4-80 mis Pre Alarm 2 limit
‘ON Delay: Os | 0-600 Minimum time of exceed Wind speed to activate the Pre
Alarm 2
‘OFF Delay. Omin 0=60 min Delay of alarm switch OFF after wind speed drop below
| preset level
Relay Normal | NormaVinverted Inverted operation of relay.
Settings: Pre Alarm 1
Factory | Setting range’ Description:
preset |
Wind Speed: | 42 km/h | 1-60 mis. Pre Alarm 4 limit
[ON Delay Os 0-6005 ‘Minimum time of exceed Wind speed to activate the Pre
Alarm 4
OFF Delay: Omin 0-60 min Delay of alarm switch OFF after wind speed drop below
| preset level
Rela Normal | Normaiinverted Inverted operation of relay
Settings: General
Factory | Setting range Deseription:
preset
‘Sensor Enclosed | 1-265 ‘Set the sensor address of your Wind speed sensor
Address: sensor
‘Averaging| 25 2 100r 30s ‘Averaging period for showed wind speed
WS units: kmh mis, kmih, mph or | Unit of displaying wind speed
| knots
| Temperature C Corr Unit of displaying Temperature
units:
20 mA Output* [480 kmih | 10-50 mis Wind speed at 20 mA output
mA =0 kmh
20 mA= seted value wind speed
* applicable only at model with additional 4-20 mA output
Password NO NOT Activation of password protection and setting of password
YES - 0000 to 9999
‘Sound Alarm: | ON
ON/OFF
‘Switching sound alarm ON and OFF.
Language: English
English/French
Language selection
RESET OF DISPLAY UNIT
With upper button pressed at power ON - the RESET is performed (all settings goes to default values).
Please adjust the corresponding sensor address after resetting the display unitSENSOR UNIT switches ON automatically when the anemometer cups revolve. Sensor unit switches ON
automatically when the anemometer cups revolve. It switches OFF 6 hours after the anemometer cups stop
revolving. In ON state position it sends new wind speed data every two seconds.
SIGNAL RECEPTION
Sign on the display blinks when the display unit receives a signal from the sensor (every 2 seconds if reception
is good). Signal strenth is numericaly shown in dB.
‘When the sensor doesn't send data (in OFF state) or when the signal is lost for a more than 30 seconds, the
“No data’ appears on the display, indicating that the receiver doesn't receive data from the sensor (sensor
OFF or out of range)
SENSOR ADDRESS
Correspondent sensor Address has already been preset at the factory
Always set the address correspond to the address of the sensor from which the receiver will recelve data.
‘Address of the sensor is indicated on the label and in the interior of battery compartment.
RANGE
Connection between sensor and display unit works on free 868 MHz band (optionaly 908MHz). Reach is up to
‘500 meters (1300 meters at “X" models) - at 10 m sensor mounting height and when there is no obstacle
between the sensor and the display unit. Inside buildings the range is much shorter. Normally the signal can be
received through two to three walls.
SENSOR BATTERY REPLACEMENT
‘When the ‘Lo battery” appears on the display, replace the sensor battery. Take off the battery cover by turning
it anti clockwise. Pull out the battery holder and insert new battery (Lithium 3,6 V AA).
TECHNICAL DATA
‘Measurement range:
Unit of measurement
‘Averaging period:
Operating voltage
Power consumption:
‘Transmission distance: type WSM W410
type WSM W410X
with 2 directional yagi antenna:
Operating Frequency:
‘Temperature operating range:
Outputs:
Signal output (type WSM W410/4-20mA):
‘Sound signal (integrated):
‘Antenna input (receiver):
Data transmission rate’
Resolution:
Accuracy:
Battery - sensor:
Sensor bearings,
Material-sensor. housing:
cups (replaceable):
Casing receiver:
Dimensions receiver:
Dimensions - sensor:
Mounting
Subject to technical modification without notice
LIMITED WARRANTY
0,6 - 50,0 m/s
m/s, km/h, knots, mph
selectable 25, 105, 30s
12-24 VOC.
max 300 mA
up to 500 m
uup to 1300 m
5-8 X nominal range
868 MHz (option 908 MHz)
25... 460°C
3x relay, contact rating 24/24 V
4..20 mA, (not isolated, common ground with supply)
4mA=0 mis
20 mA = programable 10 - 50 m/s
85 0B
50 Ohm, SMA connector
every 2 sec
0.1 mis
+-3%
3,6 V AA Lithium battery, Battery life up to 4 years
2 x precision stainless steel Ball bearing
AUPVC
PA
ABS
130 x 80x36 mm
Height 210 mm, overall diameter cup to cup 120 mm
the sensor mounts on a pipe with o 20 mm diameter
‘This product is guaranted for one year after date of purchase. During limited warranty period any defective product will be
repair cor replace with comparable product without charges. The limited waranty does not cover battery and damages of any
kind including physical caused accidentally or from misuse. Manufacturer's responsibil is limited to repair or replace the
product. Any liabiity for direct or indirect damage caused by product failure is excluded. The claimed product will be
repaired or replaced only when returned to the store where it was purchased together with original invoice.