an! (~ NAVIS WSM W410, WSM W410X MANUAL FUNCTIONS ‘1 stpage: current wind speed - current wind speed bar graph (setted max alarm level is always on % bar height) - peak wind speed in last 2 minutes bar graph (setted max alarm level is always on % bar height) = temperature = Max Alarm value - Pre alarm 2 value - unit of wind speed measurement - signal strength value (in dB) - received data package indicator 2nd page: 8 hours peak wind speed history graph with 5 minutes resolution, each row present peak wind speed during 5 minutes 3th page: 8 hours Max. alarm history graph with 5 minutes resolution ‘Switching between pages: ‘With short presses of HIST key you can enter to page 2 and 3 to see the wind speed and max. alarm history. Display will return on first page with 3 sec. press of HIST key or automatically after 1 minutes of inactivity. OPERATION OF ALARMS Pre alarm 1: when setted value is exceed the relay 1 will activate Pre alarm 2: when setted value is exceed the relay 2 will activate, yellow light will start bli sound with interrupted sound 1g and buzzer will Max alarm: when setted value is exceed the relay 3 will activate, red light will flash and buzzer will continuously sound. ‘When sound alarm is activated you can mute it by pressing upper key for 3 seconds. SETTING OF PARAMETERS 1. Hold pressed the SET key to enter the setting menu. If the password protection is active, enter correct password. The group of settings displays on display. 2. Select the group by using up and down keys and press SET key to enter into selected group. 3, By up and down keys select the parameter you wish to adjust and press SET key to enter into selected parameter. The adjustable parameter blinks. 4, By up and down key adjust the parameter value, Press SET to enter new value and move to next parameter. 5. Exiting setting menu: hold pressed the SET key to move back for one level Anemometer also return to normal operation after 2 minutes of inactivity. SETTINGS WSM W410 Settings Max Alarm select to set Max Alarm parameters Pre Alarm 2 select to set Pre Alarm 2 parameters Pre Alarm 1 select to set Pre Alarm 1 parameters General ‘select o set general parameters Settings: Max Alarm Factory _| Setting range: Description: preset \ Wind Speed: | 72 km/h 4-80 mis Max Alarm limit ‘ON Delay: Os 0-600s Minimum time of exceed Wind speed to activate the Max alarm OFF Delay: Omin 0-60 min Delay of alarm switch OFF after wind speed drop below preset level Relay = Normal | NormaVinverted inverted operation of relay Settings: Pre Alarm 2 Factory | Setting range Description: preset: Wind Speed: | §2 km/h | 4-80 mis Pre Alarm 2 limit ‘ON Delay: Os | 0-600 Minimum time of exceed Wind speed to activate the Pre Alarm 2 ‘OFF Delay. Omin 0=60 min Delay of alarm switch OFF after wind speed drop below | preset level Relay Normal | NormaVinverted Inverted operation of relay. Settings: Pre Alarm 1 Factory | Setting range’ Description: preset | Wind Speed: | 42 km/h | 1-60 mis. Pre Alarm 4 limit [ON Delay Os 0-6005 ‘Minimum time of exceed Wind speed to activate the Pre Alarm 4 OFF Delay: Omin 0-60 min Delay of alarm switch OFF after wind speed drop below | preset level Rela Normal | Normaiinverted Inverted operation of relay Settings: General Factory | Setting range Deseription: preset ‘Sensor Enclosed | 1-265 ‘Set the sensor address of your Wind speed sensor Address: sensor ‘Averaging| 25 2 100r 30s ‘Averaging period for showed wind speed WS units: kmh mis, kmih, mph or | Unit of displaying wind speed | knots | Temperature C Corr Unit of displaying Temperature units: 20 mA Output* [480 kmih | 10-50 mis Wind speed at 20 mA output mA =0 kmh 20 mA= seted value wind speed * applicable only at model with additional 4-20 mA output Password NO NOT Activation of password protection and setting of password YES - 0000 to 9999 ‘Sound Alarm: | ON ON/OFF ‘Switching sound alarm ON and OFF. Language: English English/French Language selection RESET OF DISPLAY UNIT With upper button pressed at power ON - the RESET is performed (all settings goes to default values). Please adjust the corresponding sensor address after resetting the display unit SENSOR UNIT switches ON automatically when the anemometer cups revolve. Sensor unit switches ON automatically when the anemometer cups revolve. It switches OFF 6 hours after the anemometer cups stop revolving. In ON state position it sends new wind speed data every two seconds. SIGNAL RECEPTION Sign on the display blinks when the display unit receives a signal from the sensor (every 2 seconds if reception is good). Signal strenth is numericaly shown in dB. ‘When the sensor doesn't send data (in OFF state) or when the signal is lost for a more than 30 seconds, the “No data’ appears on the display, indicating that the receiver doesn't receive data from the sensor (sensor OFF or out of range) SENSOR ADDRESS Correspondent sensor Address has already been preset at the factory Always set the address correspond to the address of the sensor from which the receiver will recelve data. ‘Address of the sensor is indicated on the label and in the interior of battery compartment. RANGE Connection between sensor and display unit works on free 868 MHz band (optionaly 908MHz). Reach is up to ‘500 meters (1300 meters at “X" models) - at 10 m sensor mounting height and when there is no obstacle between the sensor and the display unit. Inside buildings the range is much shorter. Normally the signal can be received through two to three walls. SENSOR BATTERY REPLACEMENT ‘When the ‘Lo battery” appears on the display, replace the sensor battery. Take off the battery cover by turning it anti clockwise. Pull out the battery holder and insert new battery (Lithium 3,6 V AA). TECHNICAL DATA ‘Measurement range: Unit of measurement ‘Averaging period: Operating voltage Power consumption: ‘Transmission distance: type WSM W410 type WSM W410X with 2 directional yagi antenna: Operating Frequency: ‘Temperature operating range: Outputs: Signal output (type WSM W410/4-20mA): ‘Sound signal (integrated): ‘Antenna input (receiver): Data transmission rate’ Resolution: Accuracy: Battery - sensor: Sensor bearings, Material-sensor. housing: cups (replaceable): Casing receiver: Dimensions receiver: Dimensions - sensor: Mounting Subject to technical modification without notice LIMITED WARRANTY 0,6 - 50,0 m/s m/s, km/h, knots, mph selectable 25, 105, 30s 12-24 VOC. max 300 mA up to 500 m uup to 1300 m 5-8 X nominal range 868 MHz (option 908 MHz) 25... 460°C 3x relay, contact rating 24/24 V 4..20 mA, (not isolated, common ground with supply) 4mA=0 mis 20 mA = programable 10 - 50 m/s 85 0B 50 Ohm, SMA connector every 2 sec 0.1 mis +-3% 3,6 V AA Lithium battery, Battery life up to 4 years 2 x precision stainless steel Ball bearing AUPVC PA ABS 130 x 80x36 mm Height 210 mm, overall diameter cup to cup 120 mm the sensor mounts on a pipe with o 20 mm diameter ‘This product is guaranted for one year after date of purchase. During limited warranty period any defective product will be repair cor replace with comparable product without charges. The limited waranty does not cover battery and damages of any kind including physical caused accidentally or from misuse. Manufacturer's responsibil is limited to repair or replace the product. Any liabiity for direct or indirect damage caused by product failure is excluded. The claimed product will be repaired or replaced only when returned to the store where it was purchased together with original invoice. Tels s5861 510620; FaRTEOT 851 O5DE wow nen ‘om NAVIS clektronita, Polska IT, STI2A Kamik Ennall nioGaavisatekionacom

You might also like