You are on page 1of 2

Thinwall Conduit Fittings (EMT)

Set Screw ConnectorsDie Cast Zinc

Cat. No. Noninsulated


B

Concrete Tight, when taped

Cat. No. Insulated

Conduit
Size

TC-221 Series

TC-821 Series

TC-821-SC
TC-822-SC
TC-823-SC
TC-824-SC
TC-825-SC
TC-826-SC
TC-827-SC
TC-828-SC
TC-829-SC
TC-8210-SC

2"
4"
1"
1
1 4"
112"
2"
212"
3"
312"
4"

1 32"
11332"
1916"
11516"
2932"
23364"
3316"
32564"
33164"
34764"

1 64"
13364"
12132"
2132"
238"
23964"
3932"
33164"
31932"
35364"

16"
1532"
27
1 64"
11316"
2364"
21732"
31964"
4116"
41732"
5116"

TC-221-SC
TC-222-SC
TC-223-SC
TC-224-SC
TC-225-SC
TC-226-SC
TC-227-SC
TC-228-SC
TC-229-SC
TC-2210-SC

Noninsulated
U.L. File No. E-1659212"-2"
U.L. File No. E-1275212"-4"
CSA File No. LR-18130M5712"-1", 212"-4"

17

15

Insulated
CSA File No. LR 18130M5712"-2"
U.L. File No. E-1659212"-2"
U.L. File No. E-1275212"-4"

Set Screw CouplingsDie Cast Zinc

Concrete Tight, when taped

Cat. No.

Conduit Size

TK-221
TK-222
TK-223
TK-224
TK-225
TK-226
TK-227
TK-228
TK-229
TK-2210

2"
3
4"
1"
114"
112"
2"
212"
3"
312"
4"

13364"
12932"
2"
23364"
22732"
31332"
4732"
41116"
42732"
51532"

59
64"
1532"
1716"
12732"
2116"
212"
31964"
4364"
41732"
4916"

CSA File No. LR-18130M5712"-114", 212"-4"


U.L. File No. E-1659212"-2"
U.L. File No. E-1275212"-4"

EMT Connectors 90 AngleDie Cast Zinc


Cat. No.

Trade Size

2"

1.27

1.15

0.45

2"
4"

1.37
1.86

1.15
0.95

0.45
0.52

SET SCREW TYPE


TC-921
COMPRESSION TYPE
TC-911-SC
TC-912-SC

137

1
3

Thinwall Conduit Fittings (EMT)

Heres How The Steel City


Part Number System Works
Easy to identify alphabetical prefixes:
BGBushings, Grounding
BIBushings, Insulated
BLBlanks
BUBushings
CBClamp Back
EK3 Piece Coupling
GAGround Clamp (armored ground
wire)
GCGround Clamp
HAHeavywall Adapter
HCHeavywall Connector
HKHeavywall Coupling
HOHeavywall Offset
HSHeavywall Strap
LGLocknut, Grounding
LNLocknut
LTLiquidtight
NCNon-Metallic Sheathed Cable
Connector
NSNon-Metallic Sheathed Cable
Strap
SHService Entrance Fitting
SLService Ells
SRSealing Rings
LSLocknut, Sealing
TCThinwall Connectors
TKThinwall Couplings
TOThinwall Offset
TSThinwall Strap
TXThinwall to Flexible Metallic
Conduit Fitting
UCUtility Connector
WAWasher
XCArmored Cable or Flexible
Metallic Conduit Connector
XKArmored Cable or Flexible
Metallic Conduit Coupling

1st DigitMaterial
1 = Steel
2 = Die Cast
3 = Combination Steel and Die Cast
4 = Malleable
5 = Plastic
6 = Aluminum
7 = Steel Insulated
8 = Die Cast Insulated
9 = Malleable Insulated
2nd DigitMethod
1 = Compression
2 = Set Screw
3 = Other
3rd/4th Digit Size
1 = 12"
2 = 34"
3 = 1"
4 = 114"
5 = 112"
6 = 2"
7 = 212"
8 = 3"
9 = 312"
10 = 4"
11 = 5"
12 = 6"
A few examples of the three digit identification system for thinwall fittings
are:
TK-111 12" steel, compression type
coupling
TC-714 114" steel insulated compression type connector
TC-822 34" die cast, insulated, setscrew type connector

(NOTE:SC suffix represents Steel City brand name products for some parts in this product line.)

STEEL CITY/THOMAS & BETTS CONDUIT FITTINGS


Federal Specification W-C-586
Federal Specification A-A-50552 (Superseding WF-406)
Federal Specification A-A-50553 (Superseding WF-406)
NEMA Standard FB-1
(Formerly ANSI C80.4)
Underwriters Laboratories, Inc., Standards ANSI UL-514B
Canadian Standards Association C22.2 No. 18

133