DMV Series 50-250w

You might also like

You are on page 1of 168

942-943.

qxp

6/13/2011

3L

10:15 AM

Page 942

DMV Series 50-250W


For Combustible Dusts
Champ H.I.D. Luminaires

Applications:

Options:

DMV series Champ luminaires are used:

The following special options are available


from the factory by adding suffix to luminaire
Cat. No.:

In applications made hazardous by the


presence of combustible dusts
In areas in which ignitible concentrations of
flammable gases or vapors will be present
only due to abnormal, unusual, or
accidental conditions
In marine applications where water spray
and corrosive atmospheres are
considerations
In areas where combustible dusts and
flammable vapors are present
simultaneously
In elevated ambient temperatures often
found in industrial applications
In installations where moisture, dirt, dust,
vibration, corrosion and rough usage are
problems
Wherever the damaging effects of wind,
snow, sleet, or hot sun are found
In grain handling, storage and processing
plants, coal preparation plants, coal
conveying areas, food processing plants,
manufacturing plants, refineries, chemical,
petrochemical, and other industrial process
facilities, waste or sewage treatment
facilities, offshore, dockside, and harbor
installations, and other heavy industrial
applications

Features:

3L

Cl. II, Groups E, F, G; Cl. III &


Simultaneous Presence
(175W max)
Marine & Wet Locations
3, 3R, 4, 4X; IP66

Cl. I, Div. 2, Groups A, B, C, D


Restricted Breathing Cl. I, Div. 2
& Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

Cast copper-free aluminum construction


(less than 0.4 of 1% copper) and epoxy
powder finish provide excellent resistance
to corrosion.
Seven mounting arrangements to suit any
lighting layout pendant, flexible pendant,
ceiling, wall bracket, angle stanchion,
straight stanchion, and quad-mount.
Wide range of light sources and wattages
to meet specifiers' needs: 50, 70, 100, 150
watt high pressure sodium (HPS); 70, 100,
175, 250 watt metal halide.
Hinged ballast housing for ease of
installation and maintenance.
All luminaires designed to perform in a
40C ambient temperature. Selected
luminaires are suitable for ambient
temperatures up to 65C.
Superior gasketing seals between the
mounting module, housing, and optical
assembly for optimum performance in wet
and corrosive environments.
Hubs with an integral conduit stop and
bushing to help prevent damage to field
wiring during installation.
Low ambient capability to (40C.)
Dome and 30 angle reflectors made of
bright white Krydon material provide
superior reflectivity, with twist-on feature
requiring no tools or additional hardware.
Will not chip, peel, dent, rust, or corrode.
Mogul base porcelain lamp socket.
Stainless steel open bottom guard permits
direct access to the globe for easy
relamping.

942

www.crouse-hinds.com

Description

Grounding wire for safety.


Ballasts available in voltages of 120, 208,
240, 277, 347, 480, 600 and multi-tap.*

Certifications and
Compliances:
NEC/CEC:
Class I, Division 2, Groups A, B, C, D
175W max Class II, Class III &
Simultaneous Presence (Class I, Division 2
and Class II)
Class I, Zone 2
IEC:
Zone 2 Ex nR IIC
UL Standards:
844 Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations
CSA Standards:
C22.2 No. 137
IEC Standards:
60079-15

Standard Materials:
Ballast housings and mountings copperfree aluminum (less than 0.4 of 1% copper)
Guard and exterior hardware stainless
steel
Reflectors (dome and angle) Krydon
fiberglass-reinforced polyester material
Globes heat and impact resistant,
internally fluted glass

Standard Finishes:
Copper-free aluminum epoxy powder
coat
Krydon material high reflectance white
Stainless steel natural

Electrical Ratings:
120, multi-tap* (120, 208, 240 and 277),
tri-tap (120, 277, 347) 480, 600 volts
50250W HPS; 70250W MH

US: 1-866-764-5454

CAN: 1-800-265-0502

Suffix

Restricted Breathing Construction.... S826


Class I, Division 2 & Zone 2
Suitabilty
Cooler Operating Temperatures
(T-Numbers)
Restricted Breathing/Non-Sparking
S865
Class I, Division 2 & Zone 2
Provides T3 code without conduit
or cable seals
Certified for IEC Zone 2.................... S826TB
Furnished with terminal block,
crimp terminals and dedicated
voltage ballasts (no MT, DT or TT)
Fused to protect ballast and
capacitors against abnormal line
conditions.......................................... S658*
(Not available with /MT Ballast)
(Not for use in Canada)
(Not suitable for marine applications)
Quick-Clip - Holds weight of
housing when closed. No need to
support luminaire while screwing
the housing to the cover...................
S890
Ballast-Gard starter cut-out switch
prevents starter pulsing when
lamp is cycling or inoperative;
prolongs ballast and ignitor life.
Available for use with 50150W LX
HPS only...........................................
BG
Instant restrike enables a hot HPS
lamp to immediately restrike after a
momentary loss of arc due to
voltage fluctuation or power outage.
It has no effect on the warm-up
period of cold lamps. Available for
use with 50150W LX HPS only.......
IR
Quartz auxiliary lighting comes to
full brightness immediately and
remains lit until the HID lamp attains
6070% of full illumination. For
non-hazardous locations only.
(Note: QTZ lamp not included; use
100W single ended lamp Q100DC,
Q100CL/DC, or 100Q/CL/DC)
Consult factory for top-hat
limitations..........................................
QTZ
Factory assembled with H.I.D.
lamps installed for additional labor
savings..............................................
FA
TEFLON coated globe for
additional protection against
breakage. For use with 50150W
HPS and 70175W MH (G303 only).. S808
Note:

Some T-numbers (operating temperatures)


change. See "Temperature Performance Data"
section.

Stainless steel insert top hat with


stainless steel threaded insert to
attach ballast housing.......................
Note:

S806

BG and IR options cannot be used together. IR


and QTZ options cannot be used together.

Accessories:
See pages 977978 for complete listing.
TEFLON is a registered trademark of E.I. duPont Co.
*When ordering fuses for luminaires, option S658, you
must specify the operating voltage. S658 cannot be
ordered with /MT in the catalog number.

Copyright 2011 Cooper Crouse-Hinds

942-943.qxp

6/13/2011

10:15 AM

Page 943

DMV Series 50-150W


High Pressure Sodium
For Combustible Dust Applications
Champ H.I.D. Luminaires

Cl. I, Div. 2, Groups A, B, C, D


Restricted Breathing Cl. I, Div. 2
& Zone 2 (Suffix S826)
Certified for IEC Zone 2 (Suffix
S826TB)

Cl. II, Groups E, F, G; Cl. III


& Simultaneous Presence
Marine & Wet Locations
3, 3R, 4, 4X; IP66

3L

To complete the catalog #, include information in notes 1, 2 and 3 below. For guards and other optics see DMV Series - Ordering By Components page.
BASIC CATALOG NUMBER
Mounting
Hub
Lamp
With G303 Globe
With GR305 Glass
Style
Size
Watts
and P33 Guard
Refractor *
Pendant Mount

3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
3
/4
3
/4
3
/4

50

3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
3
/4
3
/4
3
/4

50

Stanchion Mount
25 Angle

Stanchion Mount
Straight

Flexible Pendant
Mount

Ceiling Mount
Thru-Feed

Wall Mount
Thru-Feed

Quad-Mount
Pendant,
Adjustable Thru-Feed,
25 Angle, 121/ 2 Angle

DMVS2A050GP
DMVS3A050GP
DMVS2A070GP
DMVS3A070GP
DMVS2A100GP
DMVS3A100GP
DMVS2A150GP
DMVS3A150GP
DMVS2HA050GP
DMVS2HA070GP
DMVS2HA100GP
DMVS2HA150GP

DMVS2A050GR305
DMVS3A050GR305
DMVS2A070GR305
DMVS3A070GR305
DMVS2A100GR305
DMVS3A100GR305
DMVS2A150GR305
DMVS3A150GR305
DMVS2HA050GR305
DMVS2HA070GR305
DMVS2HA100GR305
DMVS2HA150GR305

50
70
100
150

DMVS2C050GP
DMVS3C050GP
DMVS2C070GP
DMVS3C070GP
DMVS2C100GP
DMVS3C100GP
DMVS2C150GP
DMVS3C150GP
DMVS2TW050GP
DMVS3TW050GP
DMVS2TW070GP
DMVS3TW070GP
DMVS2TW100GP
DMVS3TW100GP
DMVS2TW150GP
DMVS3TW150GP
DMVS25Q050GP
DMVS25Q070GP
DMVS25Q100GP
DMVS25Q150GP

DMVS2C050GR305
DMVS3C050GR305
DMVS2C070GR305
DMVS3C070GR305
DMVS2C100GR305
DMVS3C100GR305
DMVS2C150GR305
DMVS3C150GR305
DMVS2TW050GR305
DMVS3TW050GR305
DMVS2TW070GR305
DMVS3TW070GR305
DMVS2TW100GR305
DMVS3TW100GR305
DMVS2TW150GR305
DMVS3TW150GR305
DMVS25Q050GR305
DMVS25Q070GR305
DMVS25Q100GR305
DMVS25Q150GR305

11/2
11/2
11/2
11/2

50
70
100
150

DMVSJ050GP
DMVSJ070GP
DMVSJ100GP
DMVSJ150GP

DMVSJ050GR305
DMVSJ070GR305
DMVSJ100GR305
DMVSJ150GR305

11/2
11/2
11/2
11/2

50
70
100
150

DMVSP050GP
DMVSP070GP
DMVSP100GP
DMVSP150GP

DMVSP050GR305
DMVSP070GR305
DMVSP100GR305
DMVSP150GR305

70
100
150
50
70
100
150

70
100
150
50
70
100
150

3L

* For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. DMVS2A050GR302
For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. DMVS2A050GR303
2. 150W HPS Luminaires: For 55V lamps - add suffix LX;
for 100V lamps - add suffix CE. 50W HPS luminaire
is dual tap only.

1. Add voltage suffix to end of catalog number


Standard Voltage Ballasts 60Hz
NEC/UL
Voltage
Suffix

Multi Tap
/MT

Dual Tap
/DT

CEC/CSA (cUL)
120V
/120

480V
/480

Tri Tap
/TT

Dual Tap
/DT

600V CWI
/600CWI

220V 60Hz
/220

220V 50Hz
/220 50

Optional Voltage Ballasts - 50 or 60Hz


CEC/CSA (cUL) - CWI Isolated Ballasts
Voltage
Suffix

208V CWI
/208CWI

240V CWI
/240CWI

480V CWI
/480CWI

120V
/120

3. Options - Add the required option suffixes,


see page 942, in alpha-numeric order.

EXPORT

www.crouse-hinds.com

230V 50Hz
/230 50

US: 1-866-764-5454

240V 50Hz
/240 50

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

943

944-945.qxp

6/13/2011

10:16 AM

Page 944

3L DMV Series - 150-250W


Pulse Start Metal Halide

Cl. I, Div. 2, Groups A, B, C, D


Restricted Breathing Cl. I, Div. 2
& Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

For Combustible Dust Applications


Champ H.I.D. Luminaires

Cl. II, Groups E, F, G; Cl. III &


Simultaneous Presence
(175W max)
Marine & Wet Locations
3, 3R, 4, 4X; IP66

To complete the catalog #, include information in notes 1 and 2 below. For guards and other optics see DMV Series - Ordering By Components page.

Mounting
Style

BASIC CATALOG NUMBER


With GR305 Glass
Refractor *

Hub
Size

Lamp
Watts

With G303 Globe


and P33 Guard

3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
3
/4
3
/4
3
/4

150

DMVM2A150GP S828
DMVM3A150GP S828
DMVM2A175GP S828
DMVM3A175GP S828
DMVM2A200GP S828
DMVM3A200GP S828
DMVM2A250GP S828
DMVM3A250GP S828
DMVM2HA150GP S828
DMVM2HA175GP S828
DMVM2HA200GP S828
DMVM2HA250GP S828

DMVM2A150GR305 S828
DMVM3A150GR305 S828
DMVM2A175GR305 S828
DMVM3A175GR305 S828
DMVM2A200GR305 S828
DMVM3A200GR305 S828
DMVM2A250GR305 S828
DMVM3A250GR305 S828
DMVM2HA150GR305 S828
DMVM2HA175GR305 S828
DMVM2HA200GR305 S828
DMVM2HA250GR305 S828

3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
3
/4
3
/4
3
/4

150

150
175
200
250

DMVM2C150GP S828
DMVM3C150GP S828
DMVM2C175GP S828
DMVM3C175GP S828
DMVM2C200GP S828
DMVM3C200GP S828
DMVM2C250GP S828
DMVM3C250GP S828
DMVM2TW150GP S828
DMVM3TW150GP S828
DMVM2TW175GP S828
DMVM3TW175GP S828
DMVM2TW200GP S828
DMVM3TW200GP S828
DMVM2TW250GP S828
DMVM3TW250GP S828
DMVM25Q150GP S828
DMVM25Q175GP S828
DMVM25Q200GP S828
DMVM25Q250GP S828

DMVM2C150GR305 S828
DMVM3C150GR305 S828
DMVM2C175GR305 S828
DMVM3C175GR305 S828
DMVM2C200GR305 S828
DMVM3C200GR305 S828
DMVM2C250GR305 S828
DMVM3C250GR305 S828
DMVM2TW150GR305 S828
DMVM3TW150GR305 S828
DMVM2TW175GR305 S828
DMVM3TW175GR305 S828
DMVM2TW200GR305 S828
DMVM3TW200GR305 S828
DMVM2TW250GR305 S828
DMVM3TW250GR305 S828
DMVM25Q150GR305 S828
DMVM25Q175GR305 S828
DMVM25Q200GR305 S828
DMVM25Q250GR305 S828

Stanchion Mount
25 Angle

11/2
11/2
11/2
11/2

150
175
200
250

DMVMJ150GP
DMVMJ175GP
DMVMJ200GP
DMVMJ250GP

S828
S828
S828
S828

DMVMJ150GR305
DMVMJ175GR305
DMVMJ200GR305
DMVMJ250GR305

S828
S828
S828
S828

Stanchion Mount
Straight

11/2
11/2
11/2
11/2

150
175
200
250

DMVMP150GP
DMVMP175GP
DMVMP200GP
DMVMP250GP

S828
S828
S828
S828

DMVMP150GR305
DMVMP175GR305
DMVMP200GR305
DMVMP250GR305

S828
S828
S828
S828

Pendant Mount

Flexible
Pendant
Mount

Ceiling Mount
Thru-Feed

Wall Mount
Thru-Feed

200
250
150
175
200
250

175
200
250
150
175
200
250

3L

Quad-Mount
Pendant, Adjustable
Thru-Feed, 25 Angle,
121/ 2 Angle

175

* For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. DMVM2A150GR302-S828
For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. DMVM2A150GR303-S828

1. Add voltage suffix to end of catalog number


Standard Voltage Ballasts 60Hz
NEC/UL
Voltage
Suffix

Multi Tap
/MT

CEC/CSA (cUL)

120V
/120

480V
/480

Tri Tap
/TT

230V 50Hz
/230 50

240V 50Hz
/240 50

120V
/120

Optional Voltage Ballasts - 50 or 60Hz


EXPORT
Voltage
Suffix

220V 60Hz
/220

220V 50Hz
/220 50

2. Options - Add the required option suffixes, see page 942, in alpha-numeric order.

944

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

944-945.qxp

6/13/2011

10:16 AM

Page 945

DMV Series 70250W


Metal Halide
For Combustible Dust Applications
Champ H.I.D. Luminaires

Cl. I, Div. 2, Groups A, B, C, D


Restricted Breathing Cl. I, Div. 2
& Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

Cl. II, Groups E, F, G; Cl. III &


Simultaneous Presence
(175W max)
Marine & Wet Locations
3, 3R, 4, 4X; IP66

3L

To complete the catalog #, include information in notes 1, 2 and 3 below. For guards and other optics see DMV Series - Ordering By Components page.
BASIC CATALOG NUMBER
With GR305 Glass
Refractor *

Mounting
Style

Hub
Size

Lamp
Watts

With G303 Globe


and P33 Guard

Pendant Mount

3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
3
/4
3
/4
3
/4

70

DMVM2A070GP
DMVM3A070GP
DMVM2A100GP
DMVM3A100GP
DMVM2A175GP
DMVM3A175GP
DMVM2A250GP
DMVM3A250GP
DMVM2HA070GP
DMVM2HA100GP
DMVM2HA175GP
DMVM2HA250GP

DMVM2A070GR305
DMVM3A070GR305
DMVM2A100GR305
DMVM3A100GR305
DMVM2A175GR305
DMVM3A175GR305
DMVM2A250GR305
DMVM3A250GR305
DMVM2HA070GR305
DMVM2HA100GR305
DMVM2HA175GR305
DMVM2HA250GR305

3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
3
/4
3
/4
3
/4

70

70
100
175
250

DMVM2C070GP
DMVM3C070GP
DMVM2C100GP
DMVM3C100GP
DMVM2C175GP
DMVM3C175GP
DMVM2C250GP
DMVM3C250GP
DMVM2TW070GP
DMVM3TW070GP
DMVM2TW100GP
DMVM3TW100GP
DMVM2TW175GP
DMVM3TW175GP
DMVM2TW250GP
DMVM3TW250GP
DMVM25Q070GP
DMVM25Q100GP
DMVM25Q175GP
DMVM25Q250GP

DMVM2C070GR305
DMVM3C070GR305
DMVM2C100GR305
DMVM3C100GR305
DMVM2C175GR305
DMVM3C175GR305
DMVM2C250GR305
DMVM3C250GR305
DMVM2TW070GR305
DMVM3TW070GR305
DMVM2TW100GR305
DMVM3TW100GR305
DMVM2TW175GR305
DMVM3TW175GR305
DMVM2TW250GR305
DMVM3TW250GR305
DMVM25Q070GR305
DMVM25Q100GR305
DMVM25Q175GR305
DMVM25Q250GR305

Stanchion Mount
25 Angle

11/2
11/2
11/2
11/2

70
100
175
250

DMVMJ070GP
DMVMJ100GP
DMVMJ175GP
DMVMJ250GP

DMVMJ070GR305
DMVMJ100GR305
DMVMJ175GR305
DMVMJ250GR305

Stanchion Mount
Straight

11/2
11/2
11/2
11/2

70
100
175
250

DMVMP070GP
DMVMP100GP
DMVMP175GP
DMVMP250GP

DMVMP070GR305
DMVMP100GR305
DMVMP175GR305
DMVMP250GR305

Flexible
Pendant
Mount

Ceiling Mount
Thru-Feed

Wall Mount
Thru-Feed

Quad-Mount
Pendant, Adjustable
Thru-Feed, 25 Angle,
121/2 Angle

100
175
250
70
100
175
250

100
175
250
70
100
175
250

3L

* For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. DMVM2A070GR302
For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. DMVM2A070GR303
1. Add voltage suffix to end of catalog number
Standard Voltage Ballasts 60Hz
NEC/UL
Voltage
Suffix

Multi Tap
/MT

120V
/120

CEC/CSA (cUL)
480V
/480

Tri Tap
/TT

120V
/120

220V 60Hz
/220

220V 50Hz
/220 50

Optional Voltage Ballasts - 50 or 60Hz


CEC/CSA (cUL) - CWI Isolated Ballasts - 175W and 250W MH only
Voltage
Suffix

208V CWI
/208CWI

240V CWI
/240CWI

600V CWI
/600CWI

EXPORT
230V 50Hz
/230 50

240V 50Hz
/240 50

2. 70W ballast not available in 480V.


3. Options - Add the required option suffixes, see page 942, in alpha-numeric order.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

945

946-947.qxp

5/30/2011

9:45 AM

Page 946

DMV Series
Ordering by Components

3L

DMV luminaires are available in components.


A complete luminaire consists of:
I.
Champ Cover (Mounting Module)
II.
DMV Ballast Housing Include voltage and required option(s)
III.
Globe, Refractor, Guard, Reflector

I. Champ Cover (Mounting Module):


Type
Pendant

Conduit

Cat. #

/4"
1"

APM2
APM3

Flexible Pendant

/4"

HPM2

Ceiling

/4"
1"

CM2
CM3

Wall

3
/4"
1"

TWM2
TWM3

Stanchion 25 Degree Angle

11/2"

JM5

Stanchion Straight

11/2"

PM5

Quad-Mount

/4"

QM25

II. Ballast Housings:


Complete catalog number must have the voltage suffix (MT shown) and any options suffixes.
Lamp Watts

Cat. #

50
70
100
150

DMVS050/MT
DMVS070/MT
DMVS100/MT
DMVS150/MT LX

Metal Halide

70
100
175
250

DMVM070/MT
DMVM100/MT
DMVM175/MT
DMVM250/MT

3L

Lamp Type
High Pressure Sodium

III. Globe, Reflectors, Refractors, Guards:


Type

Cat. #

Globe

G303

Globe Teflon Coated

G303S808

Globe Guard

P33

Reflector Dome

RD739

Reflector Angle

RA739

Refractor Type 2

GR302

Refractor Type 3
Refractor Type 5

GR303

Large Plastic Refractor Type 2

PGR302

Large Plastic Refractor Type 3

PGR303

Large Plastic Refractor Type 5

PGR305

Refractor Guard

P23

High Bay Reflector/Lens

GRD4

946

www.crouse-hinds.com

GR305

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

946-947.qxp

5/30/2011

9:45 AM

Page 947

DMV Series

3L

Family Tree

Champ H.I.D. Luminaires

3L

*Plastic refractors are non-hazardous areas only (50-100W Max.)

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

947

948-949.qxp

5/30/2011

3L

9:46 AM

Page 948

DMV Series

Temperature Performance Data

Champ H.I.D. Luminaires


Rated
Ambient
C

Lamp

Class II, Division 1

Class I, Zone 2

Cat. #
DMVS50
DMVS50
DMVS50
DMVS70
DMVS70
DMVS70
DMVS100
DMVS100
DMVS100
DMVS150
DMVS150
DMVS150

Wattage
50
50
50
70
70
70
100
100
100
150
150
150

Type
HPS
HPS
HPS
HPS
HPS
HPS
HPS
HPS
HPS
HPS
HPS
HPS

40
55
65
40
55
65
40
55
65
40
55
65

DMVM70
DMVM70
DMVM70
DMVM100
DMVM100
DMVM100
DMVM150
DMVM150
DMVM150
DMVM175
DMVM175
DMVM175
DMVM200
DMVM200
DMVM250
DMVM250

70
70
70
100
100
100
150
150
150
175
175
175
200
200
250
250

MH
MH
MH
MH
MH
MH
MH PS
MH PS
MH PS
MH
MH
MH
MH
MH
MH
MH

40
55
65
40
55
65
40
55
65
40
55
65
40
55
40
55

T3C*
T3B*
T3A*
T3*
T3*
T2D*
T2B
T2A
T2A
T2B*
T2A*
T2A*
T2
T1 (325)
T2
T1 (325)

T3C
T3C
T3A
T3A
T3A
T2D

T2
T2
T2

EFG
EFG

EFG
EFG

T3C

T3C

T4A
T4
T4
T3C

T4A
T4
T4
T3C

T2A

T6
T5
T5
T5
T5
T4
T4
T4
T4
T4
T4
T3
T4
T3
T4
T3

T6
T5
T5
T5
T5
T4
T4
T4
T4
T4
T4
T3
T4
T3
T4
T3

T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3

60
75
85
60
75
85
105
105
105
85
85
90
75
90
75
90

13
13
26
32
42

CF
CF
CF
CF
CF

40
40
40
40
40

T3A
T3A
T3
T3
T3A

EFG
EFG
EFG
EFG
EFG

T6
T6
T6
T6
T4A

T6
T6

T4A

T6
T6
T6
T6
T4

T6
T6
T6
T6
T4

T3
T3
T3
T3

60
60
60
60
90

Induction
Induction

40
40

T3
T3

T2D

T2D

T6
T5

T6

60
75

DMVF26
DMVF39
DMVF52
DMVF64
DMVF84
DMVIG85
DMVIG165

3L

Class I, Division 2
Globe
(G303)
w/ or w/o
Reflector
(RA739 or
RD739)*
T3A
T3
T3
T3A
T3
T3
T2D
T2C
T2C
T2B
T2B
T2A

2
3
2
2
2

/
/
/
/
/

(26)
(39)
(52)
(64)
(84)

85
165

Refractor
Refractor
(G302 or
(GR302
G303 or
or
G305) or
GR303 or
Globe
GR305)
Group (G303)
T3A
EFG
T6
T3
EFG
T5
T3
EFG
T4A
T3A
EFG
T6
T3
EFG
T5
T3
EFG
T4A
T2D
EFG
T5
T2C
EFG
T4A
T2C

T2B
EFG
T3C
T2B
EFG

T2B
EFG

Globe
Simultaneous Restricted
Globe
Factory
(G303)
Presence
Breathing
(G303)
Sealed
with
Class I, Div. 2
Suffix
with
Suffix Supply
Reflector Class II, Div. 1 S826 w/
Reflector
S865
Wire
(RA739 or
(with G303
Globe
(RA739 or
AEx
Suitable
RD739)
Globe only)
(G303)
RD739)
nA nR II for C
T6
T3A
T6
T6
T3
75
T5
T3
T5
T5
T3
85
T4A
T3
T5
T5
T3
90
T6
T3A
T6
T6
T3
75
T5
T3
T5
T5
T3
85
T4A
T3
T5
T5
T3
90
T5
T3D
T6
T6
T3
75
T4A
T2C
T5
T5
T3
85

T4
T4
T3
90
T3C
T2A
T5
T5
T3
75

T4
T4
T3
85

T3
85

The Class I, Division 2 T-codes apply to luminaires without the restricted breathing (S826) or factory sealed (S865) options. These luminaires
are listed to UL 844. UL 844 specifies how the temperatures are measured.
The Class I, Zone 2 T-codes are for luminaires that are additionally listed to UL 60079-15 that specify a different method for measuring
temperatures. Since NEC 501.1 states that equipment "...for use in Class I, Zone 0, 1, or 2 locations shall be permitted in Class I, Division 2
locations..." then these luminaires are suitable for Class I, Division 2 but with lower temperature ratings. They also have the advantage of
meeting the more rigorous mechanical tests of UL 844.
*All DMVM 175W and below MH luminaires provided with Catalog number G303-S808 have a T2A T-code.
For use with refractor only when this table indicates by means of a T-code that the refractor is suitable for use with Class I, Division 2 luminaires.

948

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

948-949.qxp

5/30/2011

9:46 AM

Page 949

Dimensions & Weights

DMV Series

3L

Champ H.I.D. Luminaires


Net Luminaire Weights (lbs.):

Dimensions
In Inches:

Pendant Mount

Luminaire
Series

Lamp
Watts

Luminaire with
Globe, Guard
(lbs.)

Lamp
Watts

Luminaire with
Globe, Guard
(lbs.)

DMVS

50
100

23
241/16

70
150

231/16
261/8

DMVM

70
175

21
221/4

100
250

211/16
24

Type
Lbs.
Add for mounting modules:
Pendant
11/4
Ceiling
23/4
Quad Mount
31/2
Straight Stanchion
41/2

Quad-Mount

Type

Lbs.

Flexible Pendant
Wall
Angle Stanchion

11/2
41/2
31/2

Add for reflectors:


30 Angle
Dome
11/4
Deduct: 1 lb. for luminaire without P33 Guard.
Add: 51/2 lbs. for luminaire with GR305 refractor.

25 Angle
Stanchion Mount

Straight Stanchion Mount

Top View

Ceiling Mount

13/4

3L

Wall Mount

Luminaire with Globe, Guard, Reflectors

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

949

950-951.qxp

6/13/2011

10:17 AM

Page 950

Photometric Data

DMV Series

3L

Champ H.I.D. Luminaires


Lamp: 150W/E23-1/2 clear high pressure sodium (HPS)
Total bare lamp lumens: 16000
NOTE: All data provided is for high pressure sodium luminaires with 150W/E23-1/2 clear lamps. Use conversion factors (multipliers) shown
below for other clear lamp types and wattages. Consult Cooper Crouse-Hinds for additional photometric data on any Champ series luminaires.

Luminaire with Globe and Dome Reflector


Multipliers (for use with candela
curve only).
ConLuminaire Lamp
version
Series
Watts Factor
50
70
100

DMVS

Isofootcandle Chart: Luminaire with Globe and


Dome Reflector

0.25
0.40
0.59

Luminaire spacing ratio: 1.90

Coefficient of Utilization
Effective Floor Cavity Reflectance 20%

3L

% Reflectance
Eff. Ceil.
Wall

Room Cavity Ratio


1
2
3

80

50
30
10

.759
.719
.683

.643
.582
.530

.551
.480
.424

.476
.400
.342

.418
.340
.283

70

50
30
10

.740
.703
.669

.627
.570
.523

.538
.471
.418

.465
.394
.338

.406
.334
.280

50

50
30
10

.703
.672
.645

.595
.548
.506

.512
.455
.408

.442
.381
.332

.388
.324
.276

30

50
30
10

.669
.646
.622

.567
.528
.492

.488
.439
.399

.422
.368
.325

.370
.314
.270

10

50
30
10

.640
.619
.600

.541
.508
.479

.466
.424
.389

.403
.356
.318

.354
.305
.265

.582

.459

.370

% Reflectance
Eff. Ceil.
Wall

.299

.247

Room Cavity Ratio


6
7
8

10

80

50
30
10

.371
.296
.243

.330
.257
.208

.294
.224
.174

.267
.198
.151

.231
.164
.121

70

50
30
10

.362
.291
.238

.323
.252
.204

.288
.221
.173

.262
.195
.151

.226
.164
.121

50

50
30
10

.345
.283
.235

.309
.244
.201

.275
.215
.170

.250
.190
.148

.218
.159
.119

30

50
30
10

.331
.275
.231

.294
.239
.196

.265
.208
.168

.240
.184
.146

.209
.154
.116

10

50
30
10

.317
.266
.227

.284
.233
.193

.253
.203
.165

.231
.180
.143

.201
.150
.114

.210

.177

.149

.128

.100

950

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Isofootcandle Chart: Luminaire with Globe and 30


Angle Reflector

Isofootcandle charts show illumination in footcandles on work plane


10 feet below light center. Multiply by factor shown to convert to
other mounting heights.
Height (Ft.)

Factor

Height (Ft.)

Factor

8
12
14

1.56
.694
.510

16
20

.391
.250

Copyright 2011 Cooper Crouse-Hinds

976-977.qxp

5/30/2011

9:59 AM

Page 977

Accessories

Champ H.I.D. Luminaires

3L

VMV, LMV, DMV, VMV High Wattage


& N2MV Series
Globes

Reflectors

Dome Krydon material


G54

G24

30 Angle
Krydon material

G303

Lamp
Watts

Luminaire Series

Type

35150
50175
50250
200400
250
50175

LMVS, LMVM
VMVM, VMVS
DMVM, DMVS
VMVS
VMVM
N2MVM, N2MVS

Heat/impact
Heat/impact
Heat/impact
Heat/impact
Heat/impact
Heat/impact

Cat. #
resistant
resistant
resistant
resistant
resistant
resistant

G54
G24
G303
G303
G303
G303

Lamp Watts

Luminaire Series

Dome Cat. #

Angle Cat. #

35150
50175
50250
200400
250
50175

LMVS, LMVM
VMVM, VMVS
DMVM, DMVS
VMVS
VMVM
N2MV, N2MVF(B)

RD636
RD70
RD739
RD739
RD739
RD739

RA636
RA70
RA739
RA739
RA739
RA740

Reflector / Lens
Guards

Etched Alzak aluminum reflector/tempered glass lens

P50 use with


G54 globe

P21 use with


G24 globe

P33 use with


G303 globe

Lamp Watts

Luminaire Series

Type

Cat. #

200400
70250

VMVM, VMVS
DMVS, DMVM

Reflector/Lens
Reflector/Lens

GRD4
GRD4

3L

Globes Teflon Coated


Teflon coated for increased shatter protection
Lamp Watts

Luminaire Series

Cat. #

50175
50175

VMVM, VMVS
DMVM, DMVS

G24 S808
G303 S808

Alzak is a registered trademark of Alcoa.


Teflon is a registered trademark of E.I. DuPont Co.

P23 use with refractors


Lamp
Watts

Luminaire Series

Type

Cat. #

35150
50175
50250
200400
250
Refractors
50175

LMVS, LMVM
VMVM, VMVS
DMVM, DMVS
VMVS
VMVM
All
N2MVM, N2MVS

Copper-free aluminum
Copper-free aluminum
Stainless steel
Stainless steel
Stainless steel
Stainless steel
Stainless steel

P50
P21
P33
P33
P33
P23
P33

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

977

978-979.qxp

5/30/2011

10:00 AM

Page 978

Champ H.I.D. Luminaires

3L

Accessories

VMV, LMV, DMV, VMV High Wattage


& N2MV Series
Refractors

Safety Lighting Options


Description
Suffix
Quartz Auxiliary Lamp
QTZ
The quartz auxiliary lamp comes to full brightness instantly and
remains lit until the H.I.D. lamp attains 6070% of full illumination.
Quartz auxiliary lamps can be used with all DMV, VMV and VMV
High Wattage series Champ luminaires. Use for non-hazardous
applications ONLY.
VMV luminaires (50175W) ordered with this option must use large
glass refractor optics, not compact refractors.

R2, R5, PR2, PR3, PR5

GR302, GR303, GR305

Lamp
Watts

Luminaire
Series

I.E.S.
Type

Glass
Cat. #

Plastic (100W max.


non-hazardous)
Cat. #

50175

VMVM,
VMVS

II
III
V

R2
R3
R5

PR2
PR3
PR5

200400

VMVM,
VMVS

II
III
V

GR302
GR305
GR305

50250

DMVS,
DMVM

II
III
V

GR302
GR303
GR305

50175

N2MV

100W single ended lamp Q100CL/DC, Q100DC or 100Q/CL/DC


NOT furnished
Instant Restrike
IR
Factory installed instant restrike device will restart a hot High
Pressure Sodium lamp after a momentary power interruption,
without the typical delay for cooling.
For use in 50150W "LX" HPS luminaires.
Ballast-Gard
BG
Ballast-Gard starter cut-out switch prevents starter pulsing after a
time delay of approximately two minutes if the lamp fails to start.

PGR302
PGR303
PGR305

For use in 50400 watt HPS luminaires only.

3L

I.E.S. Distribution Curves

Type I

Type II

Type III

Type V

Luminaire
Series

I.E.S.
Type

Glass
Cat. #

VMVM,
VMVS

I
III
V

G241
G243
G245
P241

Compact Refractors

Lamp
Watts
50175

Optional stainless steel wire guard

978

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

934-935.qxp

6/13/2011

3L

10:14 AM

Page 934

LMV Series 50-150W


Low Profile Medium Base
Champ H.I.D. Luminaires

Cl. II, Groups E, F, G; Cl. III


& Simultaneous Presence
(HPS 35W, 50W)
Marine & Wet Locations
3, 3R, 4, 4X; IP66

Applications:

Options:

LMV series Champ luminaires are used:


In applications involving low luminaire
mounting heights or restricted mounting
space or where luminaire weight is a
factor
In areas in which ignitible concentrations
of flammable gases or vapors will be
present only due to abnormal, unusual,
or accidental conditions
Where combustible dusts are present
Where combustible dusts and flammable
vapors are present simultaneously
In elevated ambient temperatures often
found in industrial applications
In marine applications where water
spray and corrosive atmospheres are
considerations
Wherever the damaging effects of wind,
snow, sleet, or hot sun are found
In manufacturing plants, chemical,
petrochemical, and other industrial
process facilities, waste or sewage
treatment facilities, offshore or dockside
installations, cold storage facilities,
parking garages or wherever dust, dirt,
water, vibration and rough usage are a
problem

The following special options are available


from the factory by adding suffix to
luminaire Cat. No.:
Description
Suffix
Restricted Breathing
Construction .............................
S826
Class I, Division 2 & Zone 2
Suitability
Cooler Operating
Temperatures (T-Numbers)
Certified for IEC Zone 2............. S826TB
Furnished with terminal block,
crimp terminals and dedicated
voltage ballasts (no MT, DT,
or TT)
Fused to protect ballast and
capacitors against abnormal
line conditions .......................... S658*
(Not for use in Canada)
(Not suitable for marine
applications)
Quick-Clip - Holds weight of
housing when closed. No need
to support luminaire while
screwing the housing to the
cover ........................................
S890
Ballast-Gard starter cut-out
switch prevents starter
pulsing when lamp is cycling
or inoperative; prolongs ballast
and ignitor life. Available for use
with 50100W HPS only ............
BG
Factory assembled with H.I.D.
lamps installed for additional
labor savings .............................
FA
Stainless steel insert top
hat with stainless steel
threaded insert to attach
ballast housing ..........................
S806

Features:

3L

Cl. I, Div. 2, Groups A, B, C, D


Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

Compact, lightweight design is ideal for


low mounting heights.
Cast copper-free aluminum construction
(less than 0.4 of 1% copper) and epoxy
powder finish provide excellent
resistance to corrosion.
Seven mounting arrangements to suit
any lighting layout pendant, flexible
pendant, ceiling, wall, straight stanchion,
angle stanchion, and quad-mount.
Wide range of lamp wattages to meet
specifiers' needs: 50, 70, 100 and 150
watt (HPS); 70 and 100 watt (MH)
medium base lamps.
Hinged ballast housing for ease of
installation and maintenance.
All luminaires designed to perform in a
40C ambient temperature. Selected
luminaires are suitable for ambient
temperatures up to 65C.
Superior gasketing seals between the
mounting module, housing, and optical
assembly for optimum performance in
wet and corrosive environments.
Hubs with an integral conduit stop and
bushing to help prevent damage to field
wiring during installation.
Low ambient capability to 40C.
Dome and 30 angle reflectors made of
bright white Krydon material provide
superior reflectivity, with twist-on feature
requiring no tools or additional
hardware. Will not chip, peel, dent, rust,
or corrode.
Grounding wire for safety.
Medium base lamp sockets.
934

www.crouse-hinds.com

Certifications and
Compliances:
NEC/CEC:
Class I, Division 2, Groups A, B, C, D
HPS 35W, 50W Class II, Class III &
Simultaneous Presence (Class I,
Division 2 and Class II)
Class I, Zone 2
IEC:
Zone 2 Ex nR IIC
UL Standards:
844 Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations
CSA Standards:
C22.2 No. 137
IEC Standards:
60079-15

Standard Materials:
Ballast housings and mountings
copper-free aluminum (less than
0.4 of 1%)
Exterior hardware stainless steel
Reflectors (dome and angle) Krydon
fiberglass-reinforced polyester material
Globes heat and impact resistant,
internally fluted glass
Guards copper-free aluminum

Accessories:
See pages 977978 for complete listing

Standard Finishes:
Copper-free aluminum epoxy powder
coat
Krydon material high reflectance white
Stainless steel natural

Electrical Ratings:
120 volts, dual-tap (120/277), multi-tap*
50, 70, 100, 150 watts HPS**
70 and 100 watts MH

* When ordering fuses for luminaires, option S658, you


must specify the operating voltage. S658 cannot be
ordered with /MT in the catalog number.
** 150W HPS is not avalable with multi tap ballast.
120V only.

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

934-935.qxp

6/13/2011

10:14 AM

Page 935

Cl. I, Div. 2, Groups A, B, C, D


Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

LMV Series 50150W


High Pressure Sodium
Low Profile - Medium Base
Champ H.I.D. Luminaires

Cl. II, Groups E, F, G; Cl. III


& Simultaneous Presence
(35W, 50W)
Marine & Wet Locations
3, 3R, 4, 4X; IP66

3L

To complete the catalog #, include information in notes 1, 2 and 3 below. For guards and other optics see LMV Series - Ordering By Components page.
BASIC CATALOG NUMBER
Mounting
Style

Hub
Size

Lamp
Watts

With G54 Globe


and P50 Guard

Pendant Mount

/4
1
3
/4
1
3
/4
1
3
/4
1

50

LMVS2A050GP
LMVS3A050GP
LMVS2A070GP
LMVS3A070GP
LMVS2A100GP
LMVS3A100GP
LMVS2A150GP
LMVS3A150GP

/4
/4
3
/4
3
/4

50
70
100
150

LMVS2HA050GP
LMVS2HA070GP
LMVS2HA100GP
LMVS2HA150GP

/4
1
/4
1
3
/4
1
3
/4
1

50

70

LMVS2C050GP
LMVS3C050GP
LMVS2C070GP
LMVS3C070GP
LMVS2C100GP
LMVS3C100GP
LMVS2C150GP
LMVS3C150GP

/4
1
3
/4
1
3
/4
1
3
/4
1

50

Flexible Pendant Mount

3
3

Ceiling Mount Thru-Feed

Wall Mount Thru-Feed

70
100
150

100
150

LMVS2TW050GP
LMVS3TW050GP
LMVS2TW070GP
LMVS3TW070GP
LMVS2TW100GP
LMVS3TW100GP
LMVS2TW150GP
LMVS3TW150GP

70
100
150

/4
/4
3
/4
3
/4

50
70
100
150

LMVS25Q050GP
LMVS25Q070GP
LMVS25Q100GP
LMVS25Q150GP

Stanchion Mount
25 Angle

11/2
11/2
11/2
11/2

50
70
100
150

LMVSJ050GP
LMVSJ070GP
LMVSJ100GP
LMVSJ150GP

Stanchion Mount
Straight

11/2
11/2
11/2
11/2

50
70
100
150

LMVSP050GP
LMVSP070GP
LMVSP100GP
LMVSP150GP

3L

Quad Mount
Pendant, Adjustable
Thru-Feed, 25 Angle,
121/ 2 Angle

1. Add voltage suffix to end of catalog number


Standard Voltage Ballasts 60Hz
NEC/UL
Voltage
Suffix

Multi Tap
/MT

Dual Tap
/DT

CEC/CSA (cUL)
120V
/120

480V
/480

Tri Tap
/TT

Dual Tap
/DT

120V
/120

2. 150W HPS Luminaires: For 55V lamps - add suffix LX. 50W HPS luminaire is dual tap only. 150W HPS is not avalable with multi tap ballast. 120V only.
3. Options - Add the required option suffixes, see page 934, in alpha-numeric order.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

935

936-937.qxp

6/13/2011

3L

10:14 AM

Page 936

LMV Series 70-100W


Metal Halide

Cl. I, Div. 2, Groups A, B, C, D


Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

Low Profile - Medium Base


Champ H.I.D. Luminaires

Marine & Wet Locations


3, 3R, 4, 4X; IP66

To complete the catalog #, include information in notes 1, 2 and 3 below. For guards and other optics see LMV Series - Ordering By Components page.
BASIC CATALOG NUMBER
Mounting Style
Pendant Mount

Hub
Size

Lamp
Watts

With G54 Globe


and P50 Guard

3
/4
1
3
/4
1

70

LMVM2A070GP
LMVM3A070GP
LMVM2A100GP
LMVM3A100GP

100

/4
/4

70
100

LMVM2HA070GP
LMVM2HA100GP

3
/4
1
3
/4
1

70

LMVM2C070GP
LMVM3C070GP
LMVM2C100GP
LMVM3C100GP

3
/4
1
3
/4
1

70

Stanchion Mount
25 Angle

11/2
11/2

70
100

LMVMJ070GP
LMVMJ100GP

Stanchion Mount
Straight

11/2
11/2

70
100

LMVMP070GP
LMVMP100GP

Flexible Pendant Mount

Ceiling Mount
Thru-Feed

LMVM2TW070GP
LMVM3TW070GP
LMVM2TW100GP
LMVM3TW100GP

100

3L

Wall Mount Thru-Feed

100

1. Add voltage suffix to end of catalog number


Standard Voltage Ballasts 60Hz
NEC/UL
Voltage
Suffix

Multi Tap
/MT

CEC/CSA (cUL)
120V
/120

480V
/480

Tri Tap
/TT

120V
/120

2. 70W ballast not available in 480V.


3. Options - Add the required option suffixes, see page 934, in alpha-numeric order.

936

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

936-937.qxp

6/13/2011

10:14 AM

Page 937

LMV Series Ordering by Components

3L

LMV luminaires are available in components.


A complete luminaire consists of:
I.
II.
III.

Champ Cover (Mounting Module)


LMV Ballast Housing Include voltage and required option(s)
Globe, Guard, Reflector

I. Champ Cover (Mounting Module):


Type
Pendant

Conduit

Cat. #

/4"
1"

APM2
APM3

Flexible Pendant

/4"

HPM2

Ceiling

/4"
1"

CM2
CM3

Wall

3
/4"
1"

TWM2
TWM3

Stanchion 25 Degree Angle

11/2"

JM5

Stanchion Straight

1 /2"

PM5

Quad-Mount

/4"

QM25

II. Ballast Housings:


Complete catalog number must have the voltage suffix (MT shown) and any options suffixes.
Lamp Type
Lamp Watts
Cat. #
High Pressure Sodium

50
70
100
150

LMVS050/120
LMVS070/MT
LMVS100/MT
LMVS150/120 LX

Metal Halide

70
100

LMVM070/MT
LMVM100/MT

Type

Cat. #

Globe
Globe Guard
Reflector Dome
Reflector Angle

G54
P50
RD636
RA636

www.crouse-hinds.com

US: 1-866-764-5454

3L

III. Globe, Guards and Reflectors:

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

937

938-939.qxp

3L

5/30/2011

9:41 AM

Page 938

LMV Series

Family Tree

3L

Champ H.I.D. Luminaires

938

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

938-939.qxp

5/30/2011

9:41 AM

Page 939

LMV Series

Temperature Performance Data

3L

Champ H.I.D. Luminaires


Rated
Ambient
C

Lamp

Cat. #

Wattage

Type

LMVS50
LMVS50
LMVS50
LMVS70
LMVS70
LMVS100
LMVS100

50
50
50
70
70
100
100

HPS
HPS
HPS
HPS
HPS
HPS
HPS

LMVM70
LMVM70
LMVM100

70
70
100

LMVM150

150

40
55
65
40
55
40

Class I,
Division 2
Globe (G54)
w/ or w/o
Reflector
(RA636 or
RD636)

Class II, Division 1


Globe (G54)
w/ or w/o
Reflector
(RA636 or
Group
RD636)

Simultaneous
Presence
Class I, Div. 2
Class II, Div. 1

Class I, Zone 2
Restricted
Factory
Breathing
Sealed
Suffix
Suffix
S826 w/
S865
Globe (G24) AEx nA nR II

Supply
Wire
Suitable
for C

50

T2D
T2C
T2C
T2B
T2B
T2

EFG

T3C

T2B

T5
T4
T4
T4
T4
T4
T3

T3
T3
T3
T3
T3
T3
T3

N/A
75
85
75
85
85
90

MH
MH
MH

40
55
40

T2B
T2B

T4
T4
T3

T3
T3
T3

75
85
85

HPS

40

T1 350C

85

The Class I, Division 2 T-codes apply to luminaires without the restricted breathing (S826) or factory sealed (S865) options. These luminaires
are listed to UL 844. UL 844 specifies how the temperatures are measured.
The Class I, Zone 2 T-codes are for luminaires that are additionally listed to UL 60079-15 that specify a different method for measuring
temperatures. Since NEC 501.1 states that equipment "...for use in Class I, Zone 0, 1, or 2 locations shall be permitted in Class I, Division 2
locations..." then these luminaires are suitable for Class I, Division 2 but with lower temperature ratings. They also have the advantage of
meeting the more rigorous mechanical tests of UL 844.

3L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

939

940-941.qxp

5/30/2011

9:42 AM

Page 940

LMV Series

3L

Dimensions and Weights

Champ H.I.D. Luminaires


Dimensions

Luminaire Net Weights:

In Inches:
Luminaire
Series
LMVS

LMVM
Pendant Mount

Wall Mount

Top View

Ceiling Mount

Lamp
Watts

Luminaire
with Globe,
Guard (lbs.)

50
70
100
150

73/4
81/4
83/4
91/4

70
100

9
9

Type
Add for mounting modules:
Pendant
Flexible Pendant
Ceiling
Quad-Mount
Wall
Angle Stanchion
Straight Stanchion

Lbs.

Type
Add for reflectors:
Dome
30 Angle

lbs.

Deduct for luminaire without guard:


P50 Guard

Luminaire with Globe, Guard,


Reflectors

Straight Stanchion Mount

25 Angle Stanchion Mount

3L

Quad-Mount

940

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

11/4
11/2
23/4
31/2
41/2
31/2
41/2

1.0
1.0
/2

940-941.qxp

5/30/2011

9:42 AM

Page 941

Photometric Data

LMV Series

3L

Champ H.I.D. Luminaires


Lamp: 100W/E-17 high pressure sodium (HPS)
Total bare lamp lumens: 9500
All data provided is for high pressure sodium luminaires with 100W/E-17 clear lamps. Use conversion factors (multipliers) shown below for other lamp types and wattages. Consult Cooper
Crouse-Hinds for additional photometric data on any Champ Series.

Luminaire with Globe and Dome Reflector


Multipliers (for use with candela
curve only).
ConLuminaire Lamp
version
Series
Watts Factor
35
50
70
150

LMVS

Isofootcandle Chart: Luminaire with Globe


and Dome Reflector

0.24
0.42
0.67
1.68

Luminaire spacing ratio: 2.0

Coefficient of Utilization
Effective Floor Cavity Reflectance 20%
% Reflectance
Eff. Ceil.

Room Cavity Ratio


1

80

50
30
10

.722
.691
.663

.628
.579
.537

.545
.487
.441

.473
.408
.358

.413
.346
.296

70

50
30
10

.705
.676
.650

.613
.568
.531

.534
.479
.436

.463
.403
.355

.403
.340
.293

50

50
30
10

.671
.647
.627

.585
.548
.514

.511
.464
.426

.442
.390
.349

.387
.332
.289

30

50
30
10

.641
.623
.605

.560
.529
.501

.489
.450
.416

.424
.379
.342

.371
.322
.284

10

50
30
10

.614
.598
.584

.537
.510
.488

.470
.436
.407

.407
.367
.335

.356
.341
.279

.568

.471

.391

.319

.263

Wall

10

80

50
30
10

.366
.300
.253

.324
.259
.215

.288
.225
.180

.261
.199
.156

.226
.165
.127

70

50
30
10

.358
.295
.249

.318
.255
.212

.282
.223
.179

.256
.196
.156

.221
.165
.126

50

50
30
10

.343
.288
.246

.305
.248
.209

.271
.217
.177

.246
.192
.154

.214
.161
.124

30

50
30
10

.330
.280
.242

.292
.243
.205

.261
.210
.175

.237
.186
.152

.206
.157
.122

10

50
30
10

.317
.272
.238

.282
.237
.202

.251
.206
.172

.228
.182
.149

.199
.152
.120

.223

.187

.158

.136

.107

% Reflectance
Eff. Ceil

Isofootcandle Chart: Luminaire with Globe


and 30 Angle Reflector

3L

Wall

Room Cavity Ratio

www.crouse-hinds.com

Isofootcandle charts show illumination in footcandles on work plane


10 feet below light center. Multiply by factor shown to convert to
other mounting heights.

US: 1-866-764-5454

Height (Ft.)

Factor

Height (Ft.)

Factor

6
8
12

2.78
1.56
0.70

14
16

0.51
0.39

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

941

960-961.qxp

6/13/2011

3L

10:19 AM

Page 960

N2MV Series 50-175W


Non-metallic

3L

Champ H.I.D. Luminaires

Cl. I, Div. 2, Groups A, B, C, D


Cl. II, Groups F, G
Cl. III & Simultaneous
Presence (100W max)

Marine & Wet Locations


3, 3R, 4, 4X; IP56

Applications:

Options:

N2MV series Champ luminaires are used:


In areas in which ignitable
concentrations of flammable gases or
vapors will be present due to abnormal,
unusual or accidental conditions.
In installations where moisture, dirt,
vibration, corrosion or rough usage are
concerns.
Wherever the damaging effects of water,
wind, snow, sleet, hot sun or any
combination of these elements are
found.
Ideal for marine use; resists the harmful
effects of salt water.
Withstands the harshest of corrosive
environments.
To provide low wattage spot and
floodlighting.
For general area lighting.
In areas where the ambient temperature
will get as low as 40C (40F).
In manufacturing plants, refineries,
chemical, petrochemical and other
industrial process facilities, wastewater
and sewage treatment facilities,
offshore, dockside and harbor
installations as well as other heavy
industrial applications.

The following special options are available


from the factory by adding suffix to
luminaire Cat. No.:

Certifications and
Compliances:

Features:

Standard Materials:

Housing and mounting modules made of


polyphenylene sulfide (PPS) for strength
and maximum resistance to corrosion.
Pendant mounting module equipped
with integral hub set screws for vibration
resistance.
Hubs are provided with an integral
bushing to help prevent damage to field
wiring during installation and ground
connection for positive bonding.
Guard, hub inserts, stanchion elbow and
hardware made of stainless steel for
maximum resistance to corrosion.
Grounding wire for safety.
Stainless steel open bottom guard
permits direct access to the globe for
easy relamping.
Hinged assembly allows the luminaire to
hang free during installation to permit the
use of both hands when wiring.
One external captive screw for ease of
installation.
Handle hinge assembly doubles as a
handle for ease of installation, especially
when carrying up a ladder.

Housing, mounting modules,


component pallets polyphenylene
sulfide (PPS)
Guard, hub inserts, stanchion elbow,
hardware stainless steel
Globe heat tempered
Gaskets silicone rubber

960

www.crouse-hinds.com

NEC and CEC:


Class I, Division 2, Groups A, B, C, D
100W Maximum Class II, Class III &
Simultaneous Presence (Class I,
Division 2 and Class II)
UL Standards:
844 Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations
CSA Standards
C22.2 No. 137

Electrical Ratings:
120, multi-tap/MT (120, 208, 240 and
277), Dual-Tap/DT (120, 277 volts),
Tri-Tap/TT (120, 277, 347 volts) 480 volt,
600 volt, 220 / 240 volt-50 Hz
50150W HPS; 70175W MH and Pulse
Start MH

US: 1-866-764-5454

Description
Suffix
Wall Mount Arm. For converting
ceiling mount luminaire to a wall
mount. ................................. N2MV-WM1
Ballast-Gard starter cut-out
switch. Prevents starter pulsing
when lamp is cycling or
inoperative; prolongs ballast and
ignitor life. Available for use with
50150 watt HPS ......................
BG
Factory Assembled. For a factory
assembled luminaire with lamp
installed........................................
FA
Instant Restrike. Enables a hot
HPS lamp to immediately
restrike after a momentary loss
of arc due to voltage fluctuation
or power outage. It has no effect
on the warm-up period of cold
lamps. Available for use with
50150W LX HPS only.................
IR
Quartz Auxiliary Lighting. Comes
to full brightness immediately
and remains lit until the HID
lamp attains 6070% of full
illumination. For non-hazardous
locations only. (Note: QTZ lamp
not included; use 100W single
ended lamp Q100DC,
Q100CL/DC, or 100Q/CL/DC)
Consult factory for top-hat
limitations.....................................
QTZ
Fused. To protect ballast and
capacitor against abnormal line
conditions..................................... S658
(Not available with /MT ballast )
(Not for use in Canada)
(Not suitable for marine
applications)
Furnished with Lamps.................. S714
Teflon Coated Globe. For
additional protection against
breakage. For use with 50100W
HPS, 70175W MH and pulse
start MH....................................... S808

Accessories:
See pages 977978 for complete listing.

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

960-961.qxp

6/13/2011

10:19 AM

Page 961

N2MV Series 50150W


High Pressure Sodium

Cl. I, Div. 2, Groups A, B, C, D


Cl. II, Groups F, G
Cl. III & Simultaneous
Presence (100W max)

Non-metallic
Champ H.I.D. Luminaires

Marine & Wet Locations


3, 3R, 4, 4X; IP56

3L

To complete the catalog #, include information in notes 1, 2 and 3 below. For guards and other optics see N2MV Series - Ordering By Components page.

Mounting
Style
Pendant Mount

Ceiling Mount
Thru-Feed

Stanchion
Mount
25 Angle

Hub
Size

Lamp
Watts

/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
11/2
11/2
11/2
11/2

50

BASIC CATALOG NUMBER


With G303 Globe and
With GR305
P33 Guard
Glass Refractor *
N2MVS2A050GP
N2MVS3A050GP
N2MVS2A070GP
N2MVS3A070GP
N2MVS2A100GP
N2MVS3A100GP
N2MVS2A150GP
N2MVS3A150GP
N2MVS2C050GP
N2MVS3C050GP
N2MVS2C070GP
N2MVS3C070GP
N2MVS2C100GP
N2MVS3C100GP
N2MVS2C150GP
N2MVS3C150GP
N2MVSJ050GP
N2MVSJ070GP
N2MVSJ100GP
N2MVSJ150GP

70
100
150
50
70
100
150
50
70
100
150

N2MVS2A050GR305
N2MVS3A050GR305
N2MVS2A070GR305
N2MVS3A070GR305
N2MVS2A100GR305
N2MVS3A100GR305
N2MVS2A150GR305
N2MVS3A150GR305
N2MVS2C050GR305
N2MVS3C050GR305
N2MVS2C070GR305
N2MVS3C070GR305
N2MVS2C100GR305
N2MVS3C100GR305
N2MVS2C150GR305
N2MVS3C150GR305
N2MVSJ050GR305
N2MVSJ070GR305
N2MVSJ100GR305
N2MVSJ150GR305

* For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. N2MVS2A050GR302
For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. N2MVS2A050GR303

1. Add voltage suffix to end of catalog number


Standard Voltage Ballasts 60Hz
NEC/UL
Voltage
Suffix

Multi Tap
/MT

Dual Tap
/DT

CEC/CSA (cUL)
120V
/120

480V
/480

Tri Tap
/TT

Dual Tap
/DT

600V CWI
/600CWI

220V 60Hz
/220

220V 50Hz
/220 50

Optional Voltage Ballasts - 50 or 60Hz


CEC/CSA (cUL) - CWI Isolated Ballasts
Voltage
Suffix

208V CWI
/208CWI

240V CWI
/240CWI

480V CWI
/480CWI

120V
/120

EXPORT
230V 50Hz
/230 50

240V 50Hz
/240 50

2. 150W HPS Luminaires: For 55V lamps - add suffix LX; for 100V lamps - add suffix CE. 50W HPS luminaire is dual tap only.
3. Options - Add the required option suffixes, see page 960, in alpha-numeric order.

3L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

961

962-963.qxp

6/13/2011

3L

10:19 AM

Page 962

N2MV Series 150175W


Pulse Start Metal Halide
Non-metallic
Champ H.I.D. Luminaires

Cl. I, Div. 2, Groups A, B, C, D


Cl. II, Groups F, G
Cl. III & Simultaneous
Presence (100W max)

Marine & Wet Locations


3, 3R, 4, 4X; IP56

To complete the catalog #, include information in notes 1 and 2 below. For guards and other optics see N2MV Series - Ordering By Components page.
BASIC CATALOG NUMBER
Mounting
Style
Pendant Mount

Ceiling Mount
Thru-Feed

Hub
Size

Lamp
Watts

With G303 Globe and


P33 Guard *

With GR305S828 Glass


Refractor

3
/4
1
3
/4
1

150

N2MVM2A150GP
N2MVM3A150GP
N2MVM2A175GP
N2MVM3A175GP

S828
S828
S828
S828

N2MVM2A150GR305
N2MVM3A150GR305
N2MVM2A175GR305
N2MVM3A175GR305

S828
S828
S828
S828

3
/4
1
3
/4
1

150

N2MVM2C150GP
N2MVM3C150GP
N2MVM2C175GP
N2MVM3C175GP

S828
S828
S828
S828

N2MVM2C150GR305
N2MVM3C150GR305
N2MVM2C175GR305
N2MVM3C175GR305

S828
S828
S828
S828

Stanchion Mount 11/2


25 Angle
11/2

175

175

150
175

N2MVMJ150GP S828
N2MVMJ175GP S828

N2MVMJ150GR305 S828
N2MVMJ175GR305 S828

* For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. N2MVM2A150GR302-S828
For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. N2MVM2A150GR303-S828

1. Add voltage suffix to end of catalog number


Standard Voltage Ballasts 60Hz
NEC/UL
Voltage
Suffix

Multi Tap
/MT

CEC/CSA (cUL)

120V
/120

480V
/480

Tri Tap
/TT

230V 50Hz
/230 50

240V 50Hz
/240 50

120V
/120

Optional Voltage Ballasts - 50 or 60Hz


EXPORT
Voltage
Suffix

220V 60Hz
/220

220V 50Hz
/220 50

3L

2. Options - Add the required option suffixes, see page 960, in alpha-numeric order.

962

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

962-963.qxp

6/13/2011

10:19 AM

Page 963

N2MV Series 70175W


Metal Halide

Cl. I, Div. 2, Groups A, B, C, D


Cl. II, Groups F, G
Cl. III & Simultaneous
Presence (100W max)

Non-metallic
Champ H.I.D. Luminaires

Marine & Wet Locations


3, 3R, 4, 4X; IP56

3L

To complete the catalog #, include information in notes 1, 2 and 3 below. For guards and other optics see N2MV Series - Ordering By Components page.
BASIC CATALOG NUMBER
Mounting
Style
Pendant Mount

Hub
Size

Lamp
Watts

With G303 Globe and


P33 Guard

With GR305 Glass


Refractor *

/4
1
3
/4
1
3
/4
1

70

N2MVM2A070GP
N2MVM3A070GP
N2MVM2A100GP
N2MVM3A100GP
N2MVM2A175GP
N2MVM3A175GP

N2MVM2A070GR305
N2MVM3A070GR305
N2MVM2A100GR305
N2MVM3A100GR305
N2MVM2A175GR305
N2MVM3A175GR305

/4
1
3
/4
1
3
/4
1

70

N2MVM2C070GP
N2MVM3C070GP
N2MVM2C100GP
N2MVM3C100GP
N2MVM2C175GP
N2MVM3C175GP

N2MVM2C070GR305
N2MVM3C070GR305
N2MVM2C100GR305
N2MVM3C100GR305
N2MVM2C175GR305
N2MVM3C175GR305

11/2
11/2
11/2

70
100
175

N2MVMJ070GP
N2MVMJ100GP
N2MVMJ175GP

N2MVMJ070GR305
N2MVMJ100GR305
N2MVMJ175GR305

Ceiling Mount
Thru-Feed

100
175

Stanchion
Mount
25 Angle

100
175

* For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. N2MVM2A070GR302
For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. N2MVM2A070GR303

1. Add voltage suffix to end of catalog number


Standard Voltage Ballasts 60Hz
NEC/UL
Voltage
Suffix

Multi Tap
/MT

120V
/120

CEC/CSA (cUL)
480V
/480

Tri Tap
/TT

120V
/120

220V 60Hz
/220

220V 50Hz
/220 50

Optional Voltage Ballasts - 50 or 60Hz


CEC/CSA (cUL) - CWI Isolated Ballasts
Voltage
Suffix

208V CWI
/208CWI

240V CWI
/240CWI

600V CWI
/600CWI

EXPORT
230V 50Hz
/230 50

240V 50Hz
/240 50

3L

2. 70W ballast not available in 480V.


3. Options - Add the required option suffixes, see page 960, in alpha-numeric order.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

963

964-965.qxp

5/30/2011

3L

9:56 AM

Page 964

N2MV Series
Ordering by Components

N2MV luminaires are available in components.


A complete luminaire consists of:
I.
N2MV Cover (Mounting Module)
II.
N2MV Ballast Housing Include voltage and required option(s)
III.
Globe, Refractor, Guard, Reflector

I. N2MV Cover (Mounting Module):


Type
Pendant

Conduit

Cat. #

/4"
1"

N2APM2
N2APM3

Ceiling

/4"
1"

N2CM2
N2CM3

Wall (Use wall bracket accessory with


Ceiling Cover)
Stanchion 25 Degree Angle

/4"
1"

N2MV WM1 and N2CM2


N2MV WM1 and N2CM3

11/2"

N2JM5

II. Ballast Housings:


Complete catalog number must have the voltage suffix (MT shown) and any options suffixes.
Lamp
Lamp Type
Watts
Cat. #
High Pressure Sodium
50
N2MVS050/MT
70
N2MVS070/MT
100
N2MVS100/MT
150
N2MVS150/MT LX
Metal Halide

70
100
175

N2MVM070/MT
N2MVM100/MT
N2MVM175/MT

3L

III. Globe, Refractors, Guards and Reflectors:


Type

Cat. #

Globe
Globe Teflon Coated
Globe Guard
Reflector Dome
Reflector Angle
Refractor Type 2
Refractor Type 3
Refractor Type 5
Refractor Guard
Large Plastic Refractor Type 2
Large Plastic Refractor Type 3
Large Plastic Refractor Type 5

G303

964

www.crouse-hinds.com

G303S808
P33
RD739
RA739
GR302
GR303
GR305
P23
PGR302
PGR303
PGR305

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

N2MV Series

3L

Family Tree

Champ H.I.D Luminaires

*Plastic refractors are non-hazardous areas only (50-100W Max.)

3L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2012 Cooper Crouse-Hinds

965

966-967.qxp

6/14/2011

3L

1:15 PM

Page 966

N2MV Series

Temperature Performance Data

Champ H.I.D Luminaires

High Pressure Sodium


40
55
50
65

T4A

70

40
55
65

T3A
T3A

T4A

T2C/T4A

T2C/T4A

75
85

75
85

100

40
55
65

T2D
T2C

T4A

T2C/T4A

85
100

150

40
55
65

T2C

85

70

40
55
65

T3C
T3B

T4

T2B/T4

75
85

100

40
55
65

T2B
T2B

T4

T2B/T4

85

150
(S828)

40
55
65

T2

175
(Includes
S828)

40
55
65

T2

3L

T3A
T3A

Metal Halide

966

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

966-967.qxp

6/14/2011

1:15 PM

Page 967

N2MV Series

3L

Dimensions and Weights

Champ H.I.D. Luminaires


Dimensions
In Inches:

Ceiling Mount

Ceiling Mount Top View

3L

Pendant Mount

25 Angle Stanchion Mount

Net Luminaire Weights (lbs.):


Luminaire
Series

Lamp
Watts

Luminaire with
Globe, Guard
(lbs.)

Lamp
Watts

Luminaire with
Globe, Guard
(lbs.)

N2VMS

50
100

23
241/16

70
150

231/16
261/8

N2MVM

70
175

21
221/4

100
250

211/16
24

Type
Lbs.
Add for mounting modules:
Pendant
11/4
Ceiling
23/4
Quad-Mount
31/2
Straight Stanchion
41/2

Wall Arm Mount

www.crouse-hinds.com

Type

Lbs.

Flexible Pendant
Wall
Angle Stanchion

11/2
41/2
31/2

Add for reflectors:


30 Angle
Dome
11/ 4
Deduct: 1 lb. for luminaire without P33 Guard.
Add: 51/ 2 lbs. for luminaire with GR305 refractor.

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

13/4

967

968-969.qxp

5/30/2011

3L

9:57 AM

Page 968

N2MV Series

Photometric Data

Champ H.I.D Luminaires


Lamp: 150W/E-23-1/2 clear high pressure sodium (HPS)
Total bare lamp lumens: 16000
All data provided is for high pressure sodium luminaires with 150W/E-23-1/2 clear lamps. Use conversion factors (multipliers) shown below for other clear lamp types and wattages.
Consult Cooper Crouse-Hinds for additional photometric data on any Champ series luminiares.

Luminaire with Globe and Dome Reflector


Multipliers (for use with
candela curve only).

Luminaire
Series

Lamp
Watts

Conversion
Factor

N2MVS

50
70
100

0.25
0.40
0.59

Isofootcandle Chart: Luminaire with


Globe and Dome Reflector

Luminaire spacing ratio: 1.90

Coefficient of Utilization
Effective Floor Cavity Reflectance 20%

3L

% Reflectance
Eff. Ceil.
Wall

Room Cavity Ratio


1
2
3

80

50
30
10

.759
.719
.683

.643
.582
.530

.551
.480
.424

.476
.400
.342

.418
.340
.283

70

50
30
10

.740
.703
.669

.627
.570
.523

.538
.471
.418

.465
.394
.338

.406
.334
.280

50

50
30
10

.703
.672
.645

.595
.548
.506

.512
.455
.408

.442
.381
.332

.388
.324
.276

30

50
30
10

.669
.646
.622

.567
.528
.492

.488
.439
.399

.422
.368
.325

.370
.314
.270

10

50
30
10

.640
.619
.600

.541
.508
.479

.466
.424
.389

.403
.356
.318

.354
.305
.265

.582

.459

.370

.299

.247

Room Cavity Ratio


6
7
8

10

80

50
30
10

.371
.296
.243

.330
.257
.208

.294
.224
.174

.267
.198
.151

.231
.164
.121

70

50
30
10

.362
.291
.238

.323
.252
.204

.288
.221
.173

.262
.195
.151

.226
.164
.121

50

50
30
10

.345
.283
.235

.309
.244
.201

.275
.215
.170

.250
.190
.148

.218
.159
.119

30

50
30
10

.331
.275
.231

.294
.239
.196

.265
.208
.168

.240
.184
.146

.209
.154
.116

10

50
30
10

.317
.266
.227

.284
.233
.193

.253
.203
.165

.231
.180
.143

.201
.150
.114

.210

.177

.149

.128

.100

968

www.crouse-hinds.com

% Reflectance
Eff. Ceil.
Wall

US: 1-866-764-5454

CAN: 1-800-265-0502

Isofootcandle Chart: Luminaire with


Globe and 30 Angle Reflector

Isofootcandle charts show illumination in footcandles on work plane


10 feet below light center. Multiply by factor shown to convert to
other mounting heights.
Height (Ft.)

Factor

Height (Ft.)

Factor

8
12
14

1.56
.694
.510

16
20

.391
.250

Copyright 2011 Cooper Crouse-Hinds

968-969.qxp

5/30/2011

9:57 AM

Page 969

NVMV Series 70-400W Ex-Protected


Luminaire for IEC and ATEX Applications

Ex nR II T...Gc
Ex t IIIC T...C Db IP66
LCIE 09 ATEX 1002
LCIE 09 ATEX 3008

Champ H.I.D. Luminaires


The Champ NVMV design is optimized for
Zone 2 gas applications (with standard
restricted breathing Ex nR protection), as
well as Zone 21 dust applications.

Applications:
NVMV Ex-Protected Luminaires are suitable
for applications in Zone 2/Zone 21/Zone
22:
In manufacturing plants, refineries,
chemical, petrochemical, and other
industrial process facilities, waste or
sewage treatment facilities, dockside and
other heavy industrial applications
In areas where combustible dusts or
fibers may be present
In areas where ignitable concentrations
of flammable gases or vapors will be
present
In installations where moisture, dirt, dust,
vibration, corrosion, and rough usage are
problematic

Features:

Certifications and
Compliances:
Application in Zone 2 area acc. IEC
60079-15
Marking to 94/9/EC: Ex II 3 G Ex nR II
T*...Gc
EC - Type Examination: LCIE 09 ATEX
1002
Application in Zone 21 and 22 areas acc.
IEC 61241-1
Marking to 94/9/EC: Ex II 2 D Ex t IIIC
T...C(*) Db IP66
EC - Type Examination: LCIE 09 ATEX
3008
General per both application
Zone 2 and 21
Temperature ambient of use: -45C to
+55C
Electromagnetic compatibility: EN
61000-6-4
Degree of protection: acc. EN 60529
IP66

NVMV 70W - 250W (Small Housing)

Standard Materials and


Finishes:
Ballast housing and mountings
copper-free aluminum
Exterior hardware stainless steel
(type 304)
Reflectors (dome and angle) Krydon
fiberglass-reinforced polyester
Globes heat and impact-resistant
glass
Guards copper-free aluminum and
stainless steel (large housing - stainless
steel only)

NVMV 250W - 400W (Large Housing)

3L

One product offering for global


applications. The Champ family has the
required IEC and ATEX certifications to
provide solutions for specification
requirements around the world.
Restricted breathing (Ex nR)
protection is standard. This provides
better T-ratings, as gases will not enter
the lamp chamber and control gear
housing.
Provides an integrated ballast with
thermal cut-off functionality incorporated
into the control gear. In the event of
abnormal temperatures or when the lamp
approaches end of life, the cut-off
functionality protects the ballast from
overheating or burning out.
Identical mounting cover for IEC and
NEC applications - regardless of
wattage, options, and accessories.
Reduce inventory costs and provide
greater flexibility for engineering
designers, customers, and distributors.
HPS lamps restrike in 10-30 seconds
with the instant restrike option (IR) should
lamp extinguish due to system voltage
drop or momentary loss. Optional builtin cut-off feature will shut off the instant
restrike to avoid continuous high energy
pulsing when lamp is inoperative or
nearing end of life.
Available with the Champ Quick-Clip.
Quick-Clip secures the housing to the
cover, providing faster, easier, and safer
luminaire installation.

3L

Technical
Specifications:
Entry
Termination
Installation
Lamp Holder
Lamp Type
Lamp Power
Control Gear

Re-lamping
Burning Position
Ingress Protection
Electrical Supply

www.crouse-hinds.com

US: 1-866-764-5454

Up to 4 x M20, M25, M32, 1/ 2" NPT and 3/ 4" NPT and 1" NPT
cable entries (11/ 2" NPT for stanchion only)
3 Core 6mm2 max. (standard); 6 x 6mm2 for looping
(available upon request)
Ceiling Mount, Wall Mount, Stanchion Mount, Pendant Mount
E27 or E40
HSE/HST (high pressure sodium lamp) and HIE
(metal halide lamp)
70W, 100W, 150W, 250W, and 400W
Integrated ballast, thermal cut-off functionality incorporated
into control gear
Access via restricted breathing lamp chamber
Base up; up to 25 off vertical
IP66 to EN 60529
220, 230, 240V 50Hz and 220, 230V 60Hz

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

969

970-971.qxp

5/30/2011

9:57 AM

Page 970

NVMV Series 70-400W Ex-Protected


Luminaire for IEC and ATEX Applications

3L

Ex nR II T...Gc
Ex t IIIC T...C Db IP66
LCIE 09 ATEX 1002
LCIE 09 ATEX 3008

Champ H.I.D. Luminaires


Ordering Information:

Example of Completed Part Number - Small Body: NVMVS1MC075POO


NVMV
Series

S
Lamp

NVMV
S = HSE/HST
Luminaire (HPS)
IEC Gear
M = HIE (MH)

1M
Entry

C
Mounting*

07
5
Wattage Voltage

1M = M20
2M = M25
3M = M32
1N = 1/2" NPT
2N = 3/4" NPT
3N = 1" NPT
5N = 1 1/2" NPT
(For Stanchion)

C = Ceiling
W = Wall
J = Stanchion

07 =
70W
10 =
100W
15 =
150W
25 =
250W

3
5
6
4
7

=
=
=
=
=

220V
230V
240V
220V
230V

/
/
/
/
/

50
50
50
60
60

Hz
Hz
Hz
Hz
Hz

P
Guard

O
Body

O = Without
Guard G34
Globe
P = G251
Globe with
P22 Alum.
Guard
S = G251
Globe with
P22 SS304
Guard

O = Small Body

O = Standard

P
Guard

L
Body

Example of Completed Part Number - Large Body: NVMVS1MC255PLO


NVMV
Series

S
Lamp

3L

NVMV
S = HSE/HST
Luminaire (HPS)
IEC Gear M = HIE (MH)

1M
Entry

C
Mounting*

25
5
Wattage Voltage

1M = M20
2M = M25
3M = M32
1N = 1/2" NPT
2N = 3/4" NPT
3N = 1" NPT
5N = 1 1/2" NPT
(For Stanchion)

C = Ceiling
W = Wall
J = Stanchion

25 =
250W
40 =
400W

3
5
6
4
7

=
=
=
=
=

220V
230V
240V
220V
230V

/
/
/
/
/

50
50
50
60
60

Hz
Hz
Hz
Hz
Hz

O = Without L = Large Body


Guard G303
Globe
P = G303
Globe with
P33 SS
Guard

Options and Accessories:


Description

Suffix

Instant restrike (100W HPS and 150W HPS) (alternative solution to dual arc lamps) /IR
Dome reflector - small housing
/RD70
30 angle reflector - small housing
/RA70
Dome reflector - large housing
/RD739
30 angle reflector - large housing
/RA739
Champ Quick-Clip
/S890

*For pendant mounting, order ceiling mount with pendant bracket accessory - please consult factory.

970

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

O = Standard

970-971.qxp

5/30/2011

9:57 AM

Page 971

3L

Temperature Performance Data

NVMV Series
Champ H.I.D. Luminaires
Temperature Performance:

Refer to temperature performance data tables (below) to select luminaire that is suitable for your area specifications. These numbers are the
maximum surface temperature of the luminaire.
Note: T3 - maximum surface temperature 200C
T4 - maximum surface temperature 135C
For example: atmospheres that contain gasoline and have an ignition temperature of 536C, any fixture with the T-rating in this table can be
used.
Atmospheres that contain diethyl ether and have an ignition temperature of 160C require a luminaire with T4 ratings.

NVMV 70W - 250W (Small Housing)


GAS (Class I, Zone 2)
Ex nR II T...Gc
Catalog Number
Example

Watts

NVMVS1MC075*00

70W

NVMVS1MC105*00

100W

Lamp
Type

Rated Lamp With


Ambient Holder G34
C
Globe
Only

HSE/HST
(HPS)
150W

NVMVS1MC255*00

250W

NVMVM1MC075*00

70W

NVMVM1MC105*00

100W

NVMVM1MC155*00

150W

NVMVM1MC255*00

250W

HIE (MH)

T4
T4
T4
T4
T4
T4
T4
T3
T3
T3
T3
T3
T4
T4
T4
T4
T4
T4
T4
T3
T3
T3
T3
T3

E27
E40
E40
E40

E27
E27
E27
E40

T4
T4
T4
T4
T4
T3
T3
T3
T3
T3
T3
T3
T4
T4
T4
T4
T4
T3
T3
T3
T3
T3
T2
T2

With
With
With
G34
G251
G34
Globe
Globe Globe
and
and
Only
Reflector Reflector
T4
T4
99C
T4
T4
109C
T4
T4
114C
T4
T4
99C
T4
T3
109C
T4
T3
114C
T3
T3
122C
T3
T3
132C
T3
T3
137C
T3
T2
168C
T2
T2
178C
T2
T2
183C
T4
T4
99C
T4
T4
109C
T4
T4
114C
T4
T4
99C
T4
T3
109C
T4
T3
114C
T3
T3
122C
T3
T3
132C
T3
T3
137C
T3
T2
168C
T2
T2
178C
T2
T2
183C

With
G251
Globe
Only
109C
119C
124C
117C
127C
132C
140C
150C
155C
174C
184C
189C
109C
119C
124C
117C
127C
132C
140C
150C
155C
194C
204C
209C

With
With
G34
G251
Globe
Globe
and
and
Reflector Reflector
104C
109C
114C
119C
119C
124C
104C
128C
114C
138C
119C
143C
140C
140C
150C
150C
155C
155C
189C
218C
199C
228C
204C
233C
104C
109C
114C
119C
119C
124C
104C
128C
114C
138C
119C
143C
140C
140C
150C
150C
155C
155C
189C
218C
199C
228C
204C
233C

Cat. No. - shown with M20 Ceiling Mount, /230V, 50 Hz.

NVMV 250W - 400W (Large Housing)

Catalog Number
Example

Watts

NVMVS1MC255*L0

250W

NVMVS1MC405*L0

400W

NVMVM1MC255*L0

250W

NVMVM1MC405*L0

400W

Lamp
Type

Rated
Ambient
C

HSE/HST
(HPS)

40
50
55
40
50
55

HIE (MH)

40
50
55
40
50
55

www.crouse-hinds.com

Lamp
Holder

E40
E40

E40
E40

GAS (Class I, Zone 2)


Ex nR II T...Gc
With G303 With G303
Globe Only Globe and
Reflector

DUST (Class II, Zone 21)


Ex t IIIC T...Db
With G303 With G303
Globe Only Globe and
Reflector

T3
T3
T3
T3
T3
T3

T3
T3
T3
T3
T3
T3

137C
147C
152C
159C
169C
174C

137C
147C
152C
175C
185C
190C

T3
T3
T3
T3
T3
T3

T3
T3
T3
T3
T2
T2

137C
147C
152C
159C
169C
174C

137C
147C
152C
193C
203C
208C

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

971

3L

NVMVS1MC155*00

40
50
55
40
50
55
40
50
55
40
50
55
40
50
55
40
50
55
40
50
55
40
50
55

With
G251
Globe
Only

DUST (Class II, Zone 21)


Ex t IIIC T...Db

972-973.qxp

5/30/2011

9:58 AM

Page 972

NVMV Series

3L

Dimensions & Weights

Champ H.I.D. Luminaires

3L

Dimensions:

972

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

972-973.qxp

5/30/2011

9:58 AM

Page 973

NVMV Series

3L

Photometric Data

Champ H.I.D. Luminaires


Photometry - Large Housing:

3L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

973

974-975.qxp

3L

5/30/2011

9:59 AM

Page 974

Photometric Data

NVMV Series
Champ H.I.D. Luminaires

3L

Photometry - Large Housing:

974

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

974-975.qxp

5/30/2011

9:59 AM

Page 975

NVMV Series

3L

Photometric Data

Champ H.I.D. Luminaires


Photometry - Small Housing:

3L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

975

976-977.qxp

3L

5/30/2011

9:59 AM

Page 976

NVMV Series

Photometric Data

Champ H.I.D. Luminaires

3L

Photometry - Small Housing:

976

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

924-925.qxp

6/13/2011

3L

10:12 AM

Page 924

VMV Series 50175W


Champ H.I.D. Luminaires

Cl. I, Div. 2, Groups A, B, C, D


Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

Applications:

Options:

VMV series Champ luminaires are used:


In manufacturing plants, refineries,
chemical, petrochemical, and other
industrial process facilities, waste or
sewage treatment facilities, offshore,
dockside, and harbor installations, and
other heavy industrial applications
In areas in which ignitible concentrations
of flammable gases or vapors will be
present only due to abnormal, unusual,
or accidental conditions
Where combustible dusts are present
In marine applications where water
spray and corrosive atmospheres are
considerations
In elevated ambient temperatures often
found in industrial applications
In installations where moisture, dirt,
dust, vibration, corrosion, and rough
usage are problems
Wherever the damaging effects of water,
wind, snow, sleet, hot sun, or any
combination of these elements are found

3L

Features:
Compact, lightweight design is ideal for
medium and low mounting heights
Cast copper-free aluminum construction
(less than 0.4 of 1% copper) and epoxy
powder finish provide excellent resistance
to corrosion
Seven mounting arrangements to suit any
lighting layout pendant, flexible pendant,
ceiling, wall bracket, angle stanchion,
straight stanchion, and quad-mount
Wide range of light sources and wattages
to meet specifiers' needs: 50, 70, 100, and
150 watt high pressure sodium (HPS); 70,
100, 175 watt metal halide (MH and Pulse
Start MH)
Hinged ballast housing for ease of
installation and maintenance
Wide choice of photometric distributions.
Glass globes, refractors and compact
refractors available for all wattage
luminaires; plastic refractors (for nonhazardous applications only) for 50100
watt luminaires
All luminaires are designed to perform in a
40C ambient temperature. Selected
luminaires are suitable for ambient
temperatures up to 65C
Superior gasketing seals between the
mounting module, housing, and optical
assembly for optimum performance in wet
and corrosive environments
Hubs with an integral conduit stop and
bushing to help prevent damage to field
wiring during installation
Low ambient capability to (40C)
Dome and 30 angle reflectors made of
bright white Krydon material provide
superior reflectivity, with twist-on feature
requiring no tools or additional hardware.
Will not chip, peel, dent, rust, or corrode
Grounding wire for safety
High power factor ballasts (Min P.F. 90%)
and available in a variety of voltages to
meet local area requirements
Mogul base porcelain lamp socket
924

www.crouse-hinds.com

Cl. II, Groups E, F, G, Cl. III &


Simultaneous Presence
(HPS 50W, 70W)
Marine & Wet Locations
3, 3R, 4, 4X; IP56 to IP66

The following special options are available


from the factory by adding suffix to luminaire
Cat. No.:
Description
Suffix
Factory Sealed Champs .......................
S865
Class I, Division 2 & Zone 2
Provides T3 code without
conduit or cable seals
Restricted breathing/Non-sparking
Restricted Breathing Construction .......
S826
Class I, Division 2 & Zone 2
Suitabilty
Cooler Operating Temperatures
(T-Numbers)
Certified for IEC Zone 2........................ S826TB
Furnished with terminal block,
crimp terminals and dedicated
voltage ballasts (no MT, DT or TT)
Fused to protect ballast and
capacitors against abnormal line
Certifications and
conditions ............................................. S658*
Compliances:
(Not available with /MT Ballast)
(Not for use in Canada)
NEC & CEC:
(Not suitable for marine applications)
Class I, Division 2, Groups A, B, C, D
Quick-Clip - Holds weight of
HPS 50W, 70W Class II, Class III &
housing when closed. No need to
Simultaneous Presence (Class I,
support luminaire while screwing
Division 2 and Class II)
the housing to the cover.......................
S890
Class I, Zone 2
Ballast-Gard starter cut-out
IEC:
switch prevents starter pulsing
when lamp is cycling or inoperative;
Zone 2 Ex nR IIC
prolongs ballast and
UL Standards:
ignitor life. Available for use with
844 Hazardous (Classified) Locations
50150W LX HPS only .........................
BG
1598 Luminaires
Instant restrike enables a hot HPS
1598A Marine Locations
lamp to immediately restrike after a
momentary loss arc due to voltage
CSA Standards:
fluctuation or power outage. It has
C22.2 No. 137
no effect on the warm-up period of
IEC Standards:
cold lamps. Available for use with
60079-15
50150W LX HPS only .........................
IR
Quartz auxiliary lighting comes to
Standard Materials:
full brightness immediately and
remains lit until the HID lamp attains
Ballast housings and mountings
6070% of full illumination. For noncopper-free aluminum (less than 0.4 of
hazardous locations only. Must use
1%)
R2, R3 and R5 refractors......................
QTZ
Exterior hardware stainless steel
Refractor Mount - For ballast
Reflectors (dome and angle) Krydon
housing only. Used with R2, R3
fiberglass-reinforced polyester material
and R5 refractors ..................................
RM
Globes heat and impact resistant
Stainless steel insert top hat
internally fluted glass
with stainless steel threaded insert
Refractors glass (50175 watts); plastic to attach ballast housing ......................
S806
50100 watts), for non-hazardous
TEFLON coating on globe for
applications
increased shatter protection.................
S808
G24 only. T-Numbers not
Guards: Globe copper-free aluminum
affected
Refractor stainless steel
Factory assembled with H.I.D.
lamps installed for additional labor
Standard Finishes:
savings..................................................
FA
Copper-free aluminum epoxy powder Note: BG and IR options cannot be used together. IR and
coat
QTZ options cannot be used together.
Krydon material high reflectance white
Accessories:
Stainless steel natural
See pages 977978 for complete listing.

Electrical Ratings:

120, 208, 240, 277, 347, 480, 600, Multitap (120, 208, 240 and 277)
50 to 150W HPS; 70 to 175W MH

US: 1-866-764-5454

CAN: 1-800-265-0502

TEFLON is a registered trademark of E.I. duPont Co.


*When ordering fuses for luminaires, option S658, you must
specify the operating voltage. S658 cannot be ordered with
/MT in the catalog number.

Copyright 2011 Cooper Crouse-Hinds

924-925.qxp

6/13/2011

10:12 AM

Page 925

Cl. I, Div. 2, Groups A, B, C, D


Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

VMV Series 50150W


High Pressure Sodium
Champ H.I.D. Luminaires

Cl. II, Groups E, F, G, Cl. III &


Simultaneous Presence
(50W, 70W)
Marine & Wet Locations
3, 3R, 4, 4X; IP66

3L

To complete the catalog #, include information in notes 1, 2 and 3 below. For guards and other optics see VMV Series - Ordering By
Components page.
BASIC CATALOG NUMBER
Mounting
Hub
Lamp
With G24 Globe
With G241 Type I
With R5 Glass
Style
Size
Watts
and P21 Guard
Compact Refractor *
Refractor
50

3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
3
/4
3
/4
3
/4

50

Stanchion
Mount
25 Angle

Stanchion
Mount
Straight

Flexible
Pendant Mount

Ceiling Mount
Thru-Feed

Wall Mount
Thru-Feed

Quad-Mount
Pendant,
Adjustable,
Thru-Feed,
25 Angle,
12 Angle

VMVS2A050GP
VMVS3A050GP
VMVS2A070GP
VMVS3A070GP
VMVS2A100GP
VMVS3A100GP
VMVS2A150GP
VMVS3A150GP
VMVS2HA050GP
VMVS2HA070GP
VMVS2HA100GP
VMVS2HA150GP

VMVS2A050G241
VMVS3A050G241
VMVS2A070G241
VMVS3A070G241
VMVS2A100G241
VMVS3A100G241
VMVS2A150G241
VMVS3A150G241
VMVS2HA050G241
VMVS2HA070G241
VMVS2HA100G241
VMVS2HA150G241

VMVS2A050R5
VMVS3A050R5
VMVS2A070R5
VMVS3A070R5
VMVS2A100R5
VMVS3A100R5
VMVS2A150R5
VMVS3A150R5
VMVS2HA050R5
VMVS2HA070R5
VMVS2HA100R5
VMVS2HA150R5

50
70
100
150

VMVS2C050GP
VMVS3C050GP
VMVS2C070GP
VMVS3C070GP
VMVS2C100GP
VMVS3C100GP
VMVS2C150GP
VMVS3C150GP
VMVS2TW050GP
VMVS3TW050GP
VMVS2TW070GP
VMVS3TW070GP
VMVS2TW100GP
VMVS3TW100GP
VMVS2TW150GP
VMVS3TW150GP
VMVS25Q050GP
VMVS25Q070GP
VMVS25Q100GP
VMVS25Q150GP

VMVS2C050G241
VMVS3C050G241
VMVS2C070G241
VMVS3C070G241
VMVS2C100G241
VMVS3C100G241
VMVS2C150G241
VMVS3C150G241
VMVS2TW050G241
VMVS3TW050G241
VMVS2TW070G241
VMVS3TW070G241
VMVS2TW100G241
VMVS3TW100G241
VMVS2TW150G241
VMVS3TW150G241
VMVS25Q050G241
VMVS25Q070G241
VMVS25Q100G241
VMVS25Q150G241

VMVS2C050R5
VMVS3C050R5
VMVS2C070R5
VMVS3C070R5
VMVS2C100R5
VMVS3C100R5
VMVS2C150R5
VMVS3C150R5
VMVS2TW050R5
VMVS3TW050R5
VMVS2TW070R5
VMVS3TW070R5
VMVS2TW100R5
VMVS3TW100R5
VMVS2TW150R5
VMVS3TW150R5
VMVS25Q050R5
VMVS25Q070R5
VMVS25Q100R5
VMVS25Q150R5

11/2
11/2
11/2
11/2

50
70
100
150

VMVSJ050GP
VMVSJ070GP
VMVSJ100GP
VMVSJ150GP

VMVSJ050G241
VMVSJ070G241
VMVSJ100G241
VMVSJ150G241

VMVSJ050R5
VMVSJ070R5
VMVSJ100R5
VMVSJ150R5

11/2
11/2
11/2
11/2

50
70
100
150

VMVSP050GP
VMVSP070GP
VMVSP100GP
VMVSP150GP

VMVSP050G241
VMVSP070G241
VMVSP100G241
VMVSP150G241

VMVSP050R5
VMVSP070R5
VMVSP100R5
VMVSP150R5

70
100
150
50
70
100
150

70
100
150
50
70
100
150

3L

3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
3
/4
3
/4
3
/4

Pendant Mount

* For G243 Type III Compact Refractor, change "241" at end of catalog number to "243". Ex. VMVS2A050G243
For G245 Type V Compact Refractor, change "241" at end of catalog number to "245". Ex. VMVS2A050G245
For R2 Glass Refractor, change "R5" at end of catalog number to "R2". Ex. VMVS2A050R2.
For R3 Glass Refractor, change "R5" at end of catalog number to "R3". Ex. VMVS2A050R3.
2. 150W HPS Luminaires: For 55V lamps - add suffix LX; for 100V lamps
- add suffix CE. 50W HPS luminaire is dual tap only.

1. Add voltage suffix to end of catalog number


Standard Voltage Ballasts 60Hz
NEC/UL

CEC/CSA (cUL)

Voltage
Multi Tap
Dual Tap
120V
Suffix
/MT
/DT
/120
Multi Tap and Dual Tap ballasts are powered for 277V

480V
/480

Tri Tap
/TT

Dual Tap
/DT

600V CWI
/600CWI

220V 60Hz
/220

220V 50Hz
/220 50

Optional Voltage Ballasts - 50 or 60Hz


CEC/CSA (cUL) - CWI Isolated Ballasts
Voltage
Suffix

208V CWI
/208CWI

240V CWI
/240CWI

480V CWI
/480CWI

120V
/120

3. Options - Add the required option suffixes, see page 924,


in alpha-numeric order.

EXPORT

www.crouse-hinds.com

US: 1-866-764-5454

240V 50Hz
/240 50

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

925

926-927.qxp

6/13/2011

3L

10:13 AM

Page 926

VMV Series 150175W


Pulse Start Metal Halide

Marine & Wet Locations


3, 3R, 4, 4X; IP66

Cl. I, Div. 2, Groups A, B, C, D


Restricted Breathing Cl. I, Div. 2
& Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

Champ H.I.D. Luminaires

To complete the catalog #, include information in note 1 below. For guards and other optics see VMV Series - Ordering By Components page.

Mounting
Style

Hub
Size

Lamp
Watts

With G24 Globe


and P21 Guard

Pendant Mount

3
/4
1
3
/4
1

150

VMVM2A150GP
VMVM3A150GP
VMVM2A175GP
VMVM3A175GP

S828
S828
S828
S828

VMVM2A150G245
VMVM3A150G245
VMVM2A175G245
VMVM3A175G245

S828
S828
S828
S828

/4
/4

150
175

VMVM2HA150GP S828
VMVM2HA175GP S828

VMVM2HA150G245 S828
VMVM2HA175G245 S828

VMVM2HA150R5 S828
VMVM2HA175R5 S828

Ceiling Mount
Thru-Feed

3
/4
1
3
/4
1

150

VMVM2C150GP
VMVM3C150GP
VMVM2C175GP
VMVM3C175GP

VMVM2C150G245
VMVM3C150G245
VMVM2C175G245
VMVM3C175G245

VMVM2C150R5
VMVM3C150R5
VMVM2C175R5
VMVM3C175R5

3
/4
1
3
/4
1

150

175

S828
S828
S828
S828

VMVM2TW150GP
VMVM3TW150GP
VMVM2TW175GP
VMVM3TW175GP

175

S828
S828
S828
S828

S828
S828
S828
S828

VMVM2TW150G245
VMVM3TW150G245
VMVM2TW175G245
VMVM3TW175G245

S828
S828
S828
S828

VMVM2TW150R5
VMVM3TW150R5
VMVM2TW175R5
VMVM3TW175R5

S828
S828
S828
S828

/4
/4

150
175

VMVM25Q150GP S828
VMVM25Q175GP S828

VMVM25Q150G245 S828
VMVM25Q175G245 S828

VMVM25Q150R5 S828
VMVM25Q175R5 S828

Stanchion
Mount
25 Angle

11/2
11/2

150
175

VMVMJ150GP S828
VMVMJ175GP S828

VMVMJ150G245 S828
VMVMJ175G245 S828

VMVMJ150R5 S828
VMVMJ175R5 S828

Stanchion
Mount
Straight

11/2
11/2

150
175

VMVMP150GP S828
VMVMP175GP S828

VMVMP150G245 S828
VMVMP175G245 S828

VMVMP150R5 S828
VMVMP175R5 S828

1. Add voltage suffix to end of catalog number


Standard Voltage Ballasts 60Hz
NEC/UL
Multi Tap
/MT

120V
/120

480V
/480

CEC/CSA (cUL)
Tri Tap
/TT

120V
/120

Optional Voltage Ballasts - 50 or 60Hz


EXPORT

926

S828
S828
S828
S828

Quad-Mount
Pendant,
Adjustable ThruFeed, 25 Angle,
121/ 2 Angle

For R2 Glass Refractor, change "R5" at end of catalog number to "R2". Ex. VMVM2A150R2-S828.
For R3 Glass Refractor, change "R5" at end of catalog number to "R3". Ex. VMVM2A150R3-S828.

Voltage
Suffix

S828
S828
S828
S828

* For G241 Type I Compact Refractor, change "245" at end of catalog number to "241". Ex. VMVM2A150G241-S828
For G243 Type III Compact Refractor, change "245" at end of catalog number to "243". Ex. VMVM2A150G243-S828

Voltage
Suffix

VMVM2A150R5
VMVM3A150R5
VMVM2A175R5
VMVM3A175R5

Flexible
Pendant Mount

Wall Mount
Thru-Feed

3L

175

BASIC CATALOG NUMBER


With G245 Type V
With R5 Glass
Compact Refractor *
Refractor

220V 60Hz
/220

www.crouse-hinds.com

220V 50Hz
/220 50

US: 1-866-764-5454

230V 50Hz
/230 50

CAN: 1-800-265-0502

240V 50Hz
/240 50

Copyright 2011 Cooper Crouse-Hinds

926-927.qxp

6/13/2011

10:13 AM

Page 927

Cl. I, Div. 2, Groups A, B, C, D


Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2 (Suffix S826TB)

VMV Series 70175W


Metal Halide
Champ H.I.D. Luminaires

Marine & Wet Locations


3, 3R, 4, 4X; IP66

3L

To complete the catalog #, include information in notes 1, 2 and 3 below. For guards and other optics see VMV Series - Ordering By Components page.

Mounting
Style

Hub
Size

Pendant Mount

3
/4
1
3
/4
1
3
/4
1

Lamp
Watts

With G24 Globe


and P21 Guard

BASIC CATALOG NUMBER


With G241 Type I
With R5 Glass
Compact Refractor *
Refractor

70

VMVM2A070GP
VMVM3A070GP
VMVM2A100GP
VMVM3A100GP
VMVM2A175GP
VMVM3A175GP

VMVM2A070G241
VMVM3A070G241
VMVM2A100G241
VMVM3A100G241
VMVM2A175G241
VMVM3A175G241

VMVM2A070R5
VMVM3A070R5
VMVM2A100R5
VMVM3A100R5
VMVM2A175R5
VMVM3A175R5

100
175

Flexible
Pendant Mount

/4
/4
3
/4

70
100
175

VMVM2HA070GP
VMVM2HA100GP
VMVM2HA175GP

VMVM2HA070G241
VMVM2HA100G241
VMVM2HA175G241

VMVM2HA070R5
VMVM2HA100R5
VMVM2HA175R5

Ceiling Mount
Thru-Feed

3
/4
1
3
/4
1
3
/4
1

70

VMVM2C070GP
VMVM3C070GP
VMVM2C100GP
VMVM3C100GP
VMVM2C175GP
VMVM3C175GP

VMVM2C070G241
VMVM3C070G241
VMVM2C100G241
VMVM3C100G241
VMVM2C175G241
VMVM3C175G241

VMVM2C070R5
VMVM3C070R5
VMVM2C100R5
VMVM3C100R5
VMVM2C175R5
VMVM3C175R5

VMVM2TW070GP
VMVM3TW070GP
VMVM2TW100GP
VMVM3TW100GP
VMVM2TW175GP
VMVM3TW175GP

VMVM2TW070G241
VMVM3TW070G241
VMVM2TW100G241
VMVM3TW100G241
VMVM2TW175G241
VMVM3TW175G241

VMVM2TW070R5
VMVM3TW070R5
VMVM2TW100R5
VMVM3TW100R5
VMVM2TW175R5
VMVM3TW175R5

Wall Mount
Thru-Feed

3
/4
1
3
/4
1
3
/4
1

Quad-Mount

100
175

70
100
175

/4
/4
3
/4

70
100
175

VMVM25Q070GP
VMVM25Q100GP
VMVM25Q175GP

VMVM25Q070G241
VMVM25Q100G241
VMVM25Q175G241

VMVM25Q070R5
VMVM25Q100R5
VMVM25Q175R5

Stanchion
Mount
25 Angle

11/2
11/2
11/2

70
100
175

VMVMJ070GP
VMVMJ100GP
VMVMJ175GP

VMVMJ070G241
VMVMJ100G241
VMVMJ175G241

VMVMJ070R5
VMVMJ100R5
VMVMJ175R5

Stanchion
Mount
Straight

11/2
11/2
11/2

70
100
175

VMVMP070GP
VMVMP100GP
VMVMP175GP

VMVMP070G241
VMVMP100G241
VMVMP175G241

VMVMP070R5
VMVMP100R5
VMVMP175R5

3L

Pendant,
Adjustable
Thru-Feed,
25 Angle,
121/ 2 Angle

* For G243 Type III Compact Refractor, change "241" at end of catalog number to "243". Ex. VMVM2A070G243
For G245 Type V Compact Refractor, change "241" at end of catalog number to "245". Ex. VMVM2A070G245
For R2 Glass Refractor, change "R5" at end of catalog number to "R2". Ex. VMVM2A070R2.
For R3 Glass Refractor, change "R5" at end of catalog number to "R3". Ex. VMVM2A070R3.
1. Add voltage suffix to end of catalog number
Standard Voltage Ballasts 60Hz

2. 70W ballast not available in 480V.


NEC/UL

Voltage
Suffix

Multi Tap
/MT

120V
/120

480V
/480

Tri Tap
/TT

Optional Voltage Ballasts - 50 or 60Hz


CEC/CSA (cUL) - CWI Isolated Ballasts
Voltage
Suffix

208V CWI
/208CWI

480V CWI
/240CWI

3. Options - Add the required option suffixes, see page 924,


in alpha-numeric order.

CEC/CSA (cUL)

600V CWI
/600CWI

120V
/120

EXPORT
220V 60Hz
/220

www.crouse-hinds.com

220V 50Hz
/220 50

230V 50Hz
/230 50

US: 1-866-764-5454

240V 50Hz
/240 50

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

927

928-929.qxp

5/30/2011

9:37 AM

Page 928

VMV Series
Ordering by Components

3L

VMV luminaires are available in components.


A complete luminaire consists of:
I.

Champ Cover (Mounting Module)

II.

VMV Ballast Housing Include voltage and required option(s)

III.

Optical & Guard components Globe, Reflector, Refractor, Guard

I. Champ Cover (Mounting Module):


Type
Pendant

Conduit

Cat. #

/4"
1"

APM2
APM3

Flexible Pendant

/4"

HPM2

Ceiling

/4"
1"

CM2
CM3

Wall

3
/4"
1"

TWM2
TWM3

Stanchion 25 Degree Angle

11/2"

JM5

Stanchion Straight

1 /2"

PM5

Quad-Mount

/4"

QM25

II. Ballast Housings:


Complete catalog number must have the voltage suffix (MT shown) and any options suffixes.
Cat. #
For Globe and
Compact Refractor

Cat. #
For Large
Refractor

Lamp Watts

High
Pressure
Sodium

50
70
100
150

VMVS050/DT
VMVS070/MT
VMVS100/MT
VMVS150/MT LX

VMVS050/MT RM
VMVS070/MT RM
VMVS100/MT RM
VMVS150/MT LX RM

Metal
Halide

70
100
175

VMVM070/MT
VMVM100/MT
VMVM175/MT

VMVM070/TT RM
VMVM100/MT RM
VMVM175/MT RM

3L

Lamp Type

III. Globe, Reflectors, Refractors, Guards:


Type

Cat. #

Globe
Globe Teflon Coated
Globe Guard
Reflector Dome
Reflector Angle
Compact Refractor Type 1
Compact Refractor Type 3
Compact Refractor Type 5
Compact Refractor Guard
Large Refractor Type 2
Large Refractor Type 3
Large Refractor Type 5
Large Refractor Guard
Large Plastic Refractor Type 2
Large Plastic Refractor Type 3
Large Plastic Refractor Type 5

G24
G24 S808
P21
RD70
RA70

928

www.crouse-hinds.com

G241
G243
G245
P241
R2
R3
R5
P23
PR2
PR3
PR5

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

928-929.qxp

5/30/2011

9:37 AM

Page 929

VMV Series

3L

Family Tree

Champ H.I.D. Luminaires

3L

*Plastic refractors are for non-hazardous areas only (50100W Max.)

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

929

3L

Temperature Performance Data

VMV Series
Champ H.I.D. Luminaires

Lamp

Cat. #

Rated
Ambient
C

Class II,
Division 1

Class I, Division 2
Globe
(G24,
G241,
G245)

Class I, Zone 2

Supply Wire
Suitable For C

Globe
Globe (G24)
Restricted
(G24) w/
w/ or w/o Simultaneous Breathing Suffix
Factory
Globe
Reflector Refractor
Reflector
Presence
S826 w/
Sealed
(G24, Refractor
(RA70 or (R2, R3,
(RA70 or
Class I, Div. 2
Globe (G24,
Suffix S865 G241, (R2, R3,
RD70)
or R5)
Group
RD70)
Class II, Div. 2
G241, G245)
AEx nA nR II G245)
or R5)

Wattage

Type

VMVM70
VMVM70
VMVM70
VMVM100
VMVM100 S849
VMVM100
VMVM150
VMVM175

70
70
70
100
100
100
150
175

MH
MH
MH
MH
MH
MH
MH
MH

40
55
65
40
40
55
40
40

T3A
T3
T3
T2D
T2
T2D
T2A
T2A

T3A
T3
T3
T2D
T2
T2D
T2A
T2A

T3A
T3
T3
T2D
T2
T2D
T2B
T2B

VMVS50
VMVS50
VMVS50
VMVS70
VMVS70
VMVS100
VMVS100
VMVS150
VMVS150

50
50
50
70
70
100
100
150
150

HPS
HPS
HPS
HPS
HPS
HPS
HPS
HPS
HPS

40
55
65
40
55
40
55
40
55

T3A
T3A
T3
T3
T3
T2C
T2B
T2A
T2

T3A
T3A
T3
T3
T3
T2C
T2B
T2A
T2

T3B
T3A
T3
T3B
T3
T2D
T2C
T2B
T2A

VMVIG055
VMVIG055

55
55

Induction
Induction

40
55

T2C
T2C

T2C
T2C

EFG
EFG
EFG
EFG
EFG
EFG
EFG

T4A
T4
T4
T3C
T3C
T3A

T3A
T3
T2D
T2C
T2B
T2A

T5
T4
T4
T4
T4
T4
T3
T3

T3
T3
T3
T3
T3
T3
T3
T3

90
90
90
90
75
90
90
90

90
90
90
90
75
90
90
90

T5
T5
T5
T4
T4
T4
T3
T3
T3

T3
T3
T3
T3
T3
T3
T3
T3
T3

75
75
75
75
90
90
105
90
105

65
75
75
65
90
75
90
85
105

T6
T5

65
65

The Class I, Division 2 T-codes apply to luminaires without the restricted breathing (S826) or factory sealed (S865) options. These luminaires
are listed to UL 844. UL844 specifies how the temperatures are measured.

3L

The Class I, Zone 2 T-codes are for luminaires that are additionally listed to UL 60079-15 that specify a different method for measuring
temperatures. Since NEC 501.1 states that equipment "for use in Class I, Zone 0, 1, or 2 locations shall be permitted in Class I, Division 2
locations" then these luminaires are suitable for Class I, Division 2 but with cooler temperature ratings. They also have the advantage of
meeting the more rigorous mechanical tests of UL 844.

930

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2012 Cooper Crouse-Hinds

930-931.qxp

5/30/2011

9:38 AM

Page 931

Dimensions and Weights

VMV Series

3L

Champ H.I.D. Luminaires

Dimensions

Net Luminaire Weights:

In Inches:

Lamp Watts
Luminaire Series
50
70
Luminaire with Globe, Guards (lbs.):
VMVS
131/2
141/2
VMVM
13
Luminaire with Glass Refractor (lbs.):
VMVS
213/4
223/4
VMVM
21

Pendant Mount

Ceiling Mount Top View

Type
Lbs.
Add for mounting modules:
Pendant
11/4
Flexible Pendant
11/2
Ceiling
23/4
Wall
41/2
Add for reflectors:
Dome

11/2

100

150

141/2
131/4

141/2

223/4
211/2

223/4

175

151/2

233/4

Type

Lbs.

Quad-Mount
Angle Stanchion
Straight Stanchion

31/ 2
31/ 2
41/ 2

30 Angle

11/ 2

Deduct: /2" lb. for fixture without P21 Guard


1

Quad-Mount

Ceiling Mount

25 Angle Stanchion Mount

Straight Stanchion Mount

Luminaire With: Refractors,


Guard

3L

Wall Mount

Compact Refractor

Globe, Guard, Reflectors

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

931

932-933.qxp

5/30/2011

9:38 AM

Page 932

VMV Series

3L

Photometric Data

Champ H.I.D. Luminaires


Lamp: 100W/E 231/2 high pressure sodium (HPS)
Total bare lamp lumens: 9500
NOTE: All data provided is for high pressure sodium luminaires with 100W/E23-1/2 clear lamps. Use conversion factors (multipliers) shown below for other clear lamp types and wattages.
Consult Cooper Crouse-Hinds for additional photometric data on any Champ Series luminaire.

Luminaire with Globe and Dome Reflector


Multipliers (for use with
candela curve only).
ConLuminaire Lamp version
Series
Watts Factor
VMVS

50
70
150

Isofootcandle Chart: Luminaire with Globe and


Dome Reflector

0.42
0.67
1.68

Luminaire spacing ratio: 1.85

Coefficient of Utilization
Effective Floor Cavity Reflectance 20%

3L

% Reflectance
Eff. Ceil.
Wall

Room Cavity Ratio


1
2
3

80

50
30
10

.823
.784
.749

.707
.646
.594

.610
.538
.482

.529
.451
.391

.464
.384
.324

70

50
30
10

.804
.767
.734

.690
.633
.587

.597
.530
.477

.517
.445
.388

.452
.377
.321

50

50
30
10

.765
.735
.709

.658
.611
.569

.571
.513
.466

.494
.431
.381

.434
.368
.318

30

50
30
10

.731
.708
.685

.629
.591
.555

.546
.497
.456

.473
.419
.375

.416
.357
.312

10

50
30
10

.701
.681
.662

.603
.569
.541

.524
.482
.446

.454
.406
.367

.399
.348
.307

.644

.521

.427

.348

.288

Room Cavity Ratio


6
7
8

10

80

50
30
10

.412
.334
.278

.366
.290
.239

.326
.253
.201

.296
.224
.175

.258
.187
.142

70

50
30
10

.403
.329
.274

.359
.285
.235

.320
.250
.200

.291
.221
.174

.252
.187
.142

50

50
30
10

.386
.320
.271

.344
.277
.231

.307
.244
.197

.279
.216
.172

.244
.182
.140

30

50
30
10

.371
.312
.267

.329
.272
.227

.296
.237
.195

.269
.210
.170

.235
.178
.137

Isofootcandle charts show illumination in footcandles on work plane


10 feet below light center. Multiply by factor shown to convert to
other mounting heights.

50
30
10

.357
.304
.263

.319
.266
.224

.285
.232
.192

.260
.206
.167

.227
.173
.135

Height (Ft.)

Factor

Height (Ft.)

Factor

10

0.51
0.39

.245

.207

.176

.152

.120

2.78
1.56
0.70

14
16

6
8
12

932

www.crouse-hinds.com

% Reflectance
Eff. Ceil.
Wall

US: 1-866-764-5454

CAN: 1-800-265-0502

Isofootcandle Chart: Luminaire with Globe and 30


Angle Reflector

Copyright 2011 Cooper Crouse-Hinds

932-933.qxp

5/30/2011

9:38 AM

Page 933

VMV Series

Photometric Data

3L

Champ H.I.D. Luminaires


Lamp: 100W/E0 231/2 high pressure sodium (HPS)

Coefficient of Utilization
Effective Floor Cavity Reflectance 20%

Luminaire with I.E.S. Type V Glass Refractor

Room Cavity Ratio


1
2
3

80

50
30
10

.848
.796
.750

.709
.631
.566

.597
.509
.439

.508
.414
.341

.437
.343
.271

70

Conversion
Factor

50
30
10

.818
.770
.726

.682
.611
.552

.576
.493
.428

.489
.402
.334

.419
.331
.264

50

0.42
0.67
1.68

50
30
10

.759
.720
.685

.632
.574
.521

.533
.464
.407

.451
.377
.318

.389
.312
.253

30

50
30
10

.706
.675
.645

.586
.538
.495

.493
.435
.386

.417
.354
.302

.359
.291
.240

10

50
30
10

.658
.632
.608

.544
.504
.469

.457
.408
.366

.385
.331
.286

.331
.274
.227

.581

.441

.340

.260

.203

NOTE: Photometric data was


developed using a 100 watt
clear high pressure sodium
lamp (9500 lumens). For other
clear lamps, use the following
conversion factors (multipliers):
Luminaire Lamp
Series
Watts
VMVS

50
70
150

% Reflectance
Eff. Ceil.
Wall

Luminaire spacing ratio: 2.0

% Reflectance
Eff. Ceil.
Wall

10

80

50
30
10

.384
.292
.226

.337
.249
.189

.299
.214
.154

.272
.189
.132

.238
.159
.103

70

50
30
10

.369
.283
.218

.325
.240
.182

.288
.203
.150

.262
.183
.130

.229
.156
.105

50

50
30
10

.341
.266
.209

.301
.225
.173

.266
.195
.143

.243
.173
.124

.214
.146
.099

30

50
30
10

.316
.249
.199

.277
.213
.163

.248
.182
.136

.225
.161
.117

.198
.136
.093

10

50
30
10

.292
.233
.188

.258
.200
.154

.223
.171
.128

.209
.151
.110

.134
.127
.087

.165

.133

.108

.091

.070

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

3L

www.crouse-hinds.com

Room Cavity Ratio


6
7
8

933

950-951.qxp

6/13/2011

10:17 AM

Page 951

VMV High Wattage Series


200-400W For Medium and
High Mounting Heights

Cl. I, Div. 2, Groups A, B, C, D


Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

Champ H.I.D. Luminaires

Cl. II, Groups E, F, G; Cl. III &


Simultaneous Presence
(with Glass Refractor)
Marine (with Globe or Glass
Refractor) & Wet Locations
3, 3R, 4, 4X; IP66

Applications:

Standard Materials:

VMV high wattage series Champ luminaires are used:


In manufacturing plants, refineries, chemical, petrochemical, and
other industrial process facilities, waste or sewage treatment
facilities, and other heavy industrial applications
In applications involving medium and high mounting heights
In applications where energy-efficient, high lumen output is
required
In areas in which ignitible concentrations of flammable gases or
vapors will be present only due to abnormal, unusual, or accidental
conditions
In marine applications where water spray and corrosive
atmospheres are considerations
In elevated ambient temperatures often found in industrial
applications
In installations where moisture, dirt, dust, vibration, corrosion and
rough usage are problems
Wherever the damaging effects of water, wind, snow, sleet, hot
sun, or any combination of these elements, are problems

Ballast housings and mountings


copper-free aluminum (less than 0.4
of 1%)
Exterior hardware and guards
stainless steel
Reflectors (dome and angle)
Krydon fiberglass-reinforced
polyester material
Globes heat and impact resistant
internally fluted glass
Refractors glass
Reflector lens spun Alzak
aluminum, tempered glass, stainless
steel door frame

Features:

Certifications and Compliances:


NEC/CEC:
Class I, Division 2, Groups A, B, C, D
With Glass Refractor - Class II, Class III & Simultaneous Presence
(Class I, Division 2 and Class II)
Class I, Zone 2
IEC:
Zone 2 Ex nR IIC
UL Standards:
844 Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations
CSA Standards:
C22.2 No. 137
IEC Standards:
60079-15
www.crouse-hinds.com

Standard Finishes:

Copper-free aluminum epoxy powder coat


Alzak aluminum natural
Stainless steel natural
Krydon material high reflectance white

Options:
The following special options are available from the factory by
adding suffix to luminaire Cat. No.:
Description
Suffix
Restricted Breathing Construction...................................
S826
Class I, Division 2 & Zone 2 Suitability
Cooler Operating Temeratures (T-Numbers)
Certified for IEC Zone 2.................................................... S826TB
Furnished with terminal block crimp terminals and
dedicated voltage ballasts (no MT, DT, or TT)
Fused to protect ballast and capacitors against
abnormal line conditions
(Not available with /MT ballast)
(Not suitable for marine applications)................................ S658*
Quick-Clip - Holds weight of housing when closed.
No need to support luminaire while screwing the
housing to the cover..........................................................
S890
Quartz auxilliary lighting comes to full brightness
immediately and remains lit until the HID lamp attains
6070% of full illumination. For non-hazardous locations
only.....................................................................................
QTZ
Ballast-Gard starter cutout switch prevents starter
pulsing when lamp is cycling or inoperative; prolongs
ballast and ignitor life. Available for use with 200400W
HPS only............................................................................
BG
Factory assembled with H.I.D. lamps installed for
additional labor savings.....................................................
FA
Top hat with stainless steel threaded insert to attach
ballast housing...................................................................
S806
Note:

(Quartz lamp not included use 100W single ended lamp Q100DC,
Q100CL/DC, or 100Q/CL/DC). Consult factory for top-hat limitations.

Electrical Ratings:
120 to 600 volts and multi-tap
200, 250, 400W HPS and MH

Accessories:
See pages 977978 for complete listing.
Alzak is a registered trademark of ALCOA.
*When ordering fuses for luminaires, option S658, you must specify the operating voltage.
S658 cannot be ordered with /MT in the catalog number.
Not for use in Canada.
Suffix S826 and S826TB cannot be used with GRD4 Reflector/Lens.

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

951

3L

Cast copper-free aluminum construction (less than 0.4 of 1%


copper) and epoxy powder finish provide excellent resistance to
corrosion
Six mounting arrangements to suit any lighting layout pendant, ceiling,
wall bracket, angle stanchion, straight stanchion and quad-mount
Wide range of light sources and wattages to meet specifiers'
needs: 200, 250, 400 watt high pressure sodium (HPS); 250 and
400 watt metal halide (MH) and pulse start metal halide
Hinged ballast housing for ease of installation and maintenance
Wide choice of photometric distributions. Glass globes, glass
refractors, and reflector/lens are available
All luminaires designed to perform in a 40C ambient temperature.
Selected luminaires are suitable for ambient temperatures up to 65C
Superior gasketing seals between the mounting module, housing,
and optical assembly for optimum performance in wet and
corrosive environments
Hubs with integral conduit stop and bushing to help prevent
damage to field wiring during installation
Low ambient capability to (40C)
Dome and 30 angle reflectors made of bright white Krydon
material and etched Alzak high bay reflectors provide superior
reflectivity
Grounding wire for safety
High power factor ballasts (Min. P. F. 90%) are available in a
variety of voltages to meet local area requirements
Mogul base lamp socket

3L

952-953.qxp

6/13/2011

10:17 AM

Page 952

Cl. I, Div. 2, Groups A, B, C, D


Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

3L VMV High Wattage Series


200-400W High Pressure Sodium
For Medium and High Mounting Heights
Champ H.I.D. Luminaires

Cl. II, Groups E, F, G; Cl. III &


Simultaneous Presence
(with Glass Refractor)
Marine (with Globe or Glass
Refractor) & Wet Locations
3, 3R, 4, 4X; IP56 to IP66

To complete the catalog #, include information in notes 1 and 2 below. For guards and other optics see VMV High Wattage Series - Ordering
By Components page.
BASIC CATALOG NUMBER
Mounting
Style

Hub
Size

Lamp
Watts

With G303 Globe


and P33 Guard

With GR305 Glass


Refractor *

With GRD4
Reflector/Lens

Pendant Mount
(Rigid or Flexible)

/4
1
3
/4
1
3
/4
1

200

VMVS2A200GP
VMVS3A200GP
VMVS2A250GP
VMVS3A250GP
VMVS2A400GP
VMVS3A400GP

VMVS2A200GR305
VMVS3A200GR305
VMVS2A250GR305
VMVS3A250GR305
VMVS2A400GR305
VMVS3A400GR305

VMVS2A200GRD4
VMVS3A200GRD4
VMVS2A250GRD4
VMVS3A250GRD4
VMVS2A400GRD4
VMVS3A400GRD4

/4
1
/4
1
3
/4
1

200

250

VMVS2C200GP
VMVS3C200GP
VMVS2C250GP
VMVS3C250GP
VMVS2C400GP
VMVS3C400GP

VMVS2C200GR305
VMVS3C200GR305
VMVS2C250GR305
VMVS3C250GR305
VMVS2C400GR305
VMVS3C400GR305

VMVS2C200GRD4
VMVS3C200GRD4
VMVS2C250GRD4
VMVS3C250GRD4
VMVS2C400GRD4
VMVS3C400GRD4

/4
1
/4
1
3
/4
1

200

250

VMVS2TW200GP
VMVS3TW200GP
VMVS2TW250GP
VMVS3TW250GP
VMVS2TW400GP
VMVS3TW400GP

VMVS2TW200GR305
VMVS3TW200GR305
VMVS2TW250GR305
VMVS3TW250GR305
VMVS2TW400GR305
VMVS3TW400GR305

Ceiling Mount
Thru-Feed

Wall Mount
Thru-Feed

250
400

400

400

3
3

/4
/4
3
/4

200
250
400

VMVS25Q200GP
VMVS25Q250GP
VMVS25Q400GP

VMVS25Q200GR305
VMVS25Q250GR305
VMVS25Q400GR305

VMVS25Q200GRD4
VMVS25Q250GRD4
VMVS25Q400GRD4

Stanchion Mount
25 Angle

11/2
11/2
11/2

200
250
400

VMVSJ200GP
VMVSJ250GP
VMVSJ400GP

VMVSJ200GR305
VMVSJ250GR305
VMVSJ400GR305

VMVSJ200GRD4
VMVSJ250GRD4
VMVSJ400GRD4

Stanchion Mount
Straight

11/2
11/2
11/2

200
250
400

VMVSP200GP
VMVSP250GP
VMVSP400GP

VMVSP200GR305
VMVSP250GR305
VMVSP400GR305

3L

Quad-Mount
Pendant, Adjustable
Thru-Feed, 25 Angle,
121/ 2 Angle

* For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. VMVS2A200GR302
For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. VMVS2A200GR303

1. Add voltage suffix to end of catalog number


Standard Voltage Ballasts 60Hz
NEC/UL
Voltage
Suffix

Multi Tap
/MT

120V
/120

CEC/CSA (cUL)
480V
/480

Tri Tap
/TT

120V
/120

220V 60Hz
/220

220V 50Hz
/220 50

Optional Voltage Ballasts - 50 or 60Hz


CEC/CSA (cUL) - CWI Isolated Ballasts
Voltage
Suffix

208V CWI
/208CWI

240V CWI
/240CWI

480V CWI
/480CWI

600V CWI
/600CWI

EXPORT
230V 50Hz
/230 50

240V 50Hz
/240 50

2. Options - Add the required option suffixes, see page 951, in alpha-numeric order.

952

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

VMV High Wattage Series 250400W Pulse Start Metal Halide

Cl. I, Div. 2, Groups A, B, C, D


Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

For Medium and High Mounting Heights


Champ H.I.D. Luminaires

Cl. II, Groups E, F, G; Cl. III &


Simultaneous Presence
(with Glass Refractor)
Marine (with Globe or Glass
Refractor) & Wet Locations
3, 3R, 4, 4X; IP56 to IP66

3L

To complete the catalog #, include information in notes 1 and 2 below. For guards and other optics see VMV High Wattage Series - Ordering
By Components page.
BASIC CATALOG NUMBER
Mounting
Style

Hub
Size

Lamp
Watts

With G303 Globe


and P33 Guard

With GR305 Glass


Refractor *

Pendant
Mount
(Rigid or
Flexible)

3
/4
1
3
/4
1
3
/4
1

250

VMVM2A250GP
VMVM3A250GP
VMVM2A320GP
VMVM3A320GP
VMVM2A400GP
VMVM3A400GP

S828
S828
S828
S828
S828
S828

VMVM2A250GR305
VMVM3A250GR305
VMVM2A320GR305
VMVM3A320GR305
VMVM2A400GR305
VMVM3A400GR305

S828
S828
S828
S828
S828
S828

VMVM2A250GRD4
VMVM3A250GRD4
VMVM2A320GRD4
VMVM3A320GRD4
VMVM2A400GRD4
VMVM3A400GRD4

S828
S828
S828
S828
S828
S828

3
/4
1
3
/4
1
3
/4
1

250

VMVM2C250GP
VMVM3C250GP
VMVM2C320GP
VMVM3C320GP
VMVM2C400GP
VMVM3C400GP

S828
S828
S828
S828
S828
S828

VMVM2C250GR305
VMVM3C250GR305
VMVM2C320GR305
VMVM3C320GR305
VMVM2C400GR305
VMVM3C400GR305

S828
S828
S828
S828
S828
S828

VMVM2C250GRD4
VMVM3C250GRD4
VMVM2C320GRD4
VMVM3C320GRD4
VMVM2C400GRD4
VMVM3C400GRD4

S828
S828
S828
S828
S828
S828

3
/4
1
3
/4
1
3
/4
1

250

Ceiling Mount
Thru-Feed

Wall Mount
Thru-Feed

320
400**

320
400**

320
400**

VMVM2TW250GP
VMVM3TW250GP
VMVM2TW320GP
VMVM3TW320GP
VMVM2TW400GP
VMVM3TW400GP

S828
S828
S828
S828
S828
S828

With GRD4
Reflector/Lens

VMVM2TW250GR305
VMVM3TW250GR305
VMVM2TW320GR305
VMVM3TW320GR305
VMVM2TW400GR305
VMVM3TW400GR305

S828
S828
S828
S828
S828
S828

/4
/4
/4

250
320
400**

VMVM25Q250GP S828
VMVM25Q320GP S828
VMVM25Q400GP S828

VMVM25Q250GR305 S828
VMVM25Q320GR305 S828
VMVM25Q400GR305 S828

VMVM25Q250GRD4 S828
VMVM25Q320GRD4 S828
VMVM25Q400GRD4 S828

Stanchion
Mount
25 Angle

11/2
11/2
11/2

250
320
400**

VMVMJ250GP S828
VMVMJ320GP S828
VMVMJ400GP S828

VMVMJ250GR305 S828
VMVMJ320GR305 S828
VMVMJ400GR305 S828

VMVMJ250GRD4 S828
VMVMJ320GRD4 S828
VMVMJ400GRD4 S828

Stanchion
Mount
Straight

11/2
11/2
11/2

250
320
400**

VMVMP250GP S828
VMVMP320GP S828
VMVMP400GP S828

VMVMP250GR305 S828
VMVMP320GR305 S828
VMVMP400GR305 S828

3
3

3L

Quad-Mount
Pendant,
Adjustable
Thru-Feed,
25 Angle,
121/ 2 Angle

* For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. VMVM2A250GR302-S828
For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. VMVM2A250GR303-S828
** To be used with ED28 (bulb shaped lamp).

1. Add voltage suffix to end of catalog number


Standard Voltage Ballasts 60Hz
NEC/UL
Voltage
Suffix

Multi Tap
/MT

120V
/120

Lamp Selection Table:


CEC/CSA (cUL)

480V
/480

Tri Tap
/TT

230V 50Hz
/230 50

240V 50Hz
/240 50

Fixture

Lamp Type

Bulb

120V
/120

Venture

Phillips

Sylvania

MP 320W/BU/ED28/UVS/PS/EM/950 MS320/U/PS

MS320/PS/BU-HOR

MP 320W/BU/ED28/UVS/PS/740

MS320/C/BU/PS

MP 320W/C/BU/ED28/EVS/PS/737

Optional Voltage Ballasts - 50 or 60Hz


EXPORT
Voltage
Suffix

220V 60Hz
/220

220V 50Hz
/220 50

VMVM320GP

320W PS MH

ED28, BT28

2. Options - Add the required option suffixes, see page 0000,


in alpha-numeric order.
VMVM400GP

www.crouse-hinds.com

400W PS MH

US: 1-866-764-5454

ED28, BT28

MP 400W/BU/ED28/UVS/PS/EM/950 N/A

CAN: 1-800-265-0502

Copyright 2012 Cooper Crouse-Hinds

M400/PS/U/BT28

953

954-955.qxp

6/13/2011

3L

10:18 AM

Page 954

VMV High Wattage Series


250-400W Metal Halide

Cl. I, Div. 2, Groups A, B, C, D


Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
For Medium and High Mounting Heights (Suffix S826TB)

Champ H.I.D. Luminaires

Cl. II, Groups E, F, G; Cl. III &


Simultaneous Presence
(with Glass Refractor)
Marine (with Globe or Glass
Refractor) & Wet Locations
3, 3R, 4, 4X; IP56 to IP66

To complete the catalog #, include information in notes 1 and 2 below. For guards and other optics see VMV High Wattage Series - Ordering
By Components page.
BASIC CATALOG NUMBER
Mounting
Hub
Lamp
With G303 Globe
With GR305 Glass
With GRD4
Style
Size
Watts
and P33 Guard
Refractor *
Reflector/Lens
Pendant Mount
(Rigid or Flexible)

Ceiling Mount
Thru-Feed

/4
1
/4
1

250

400

/4
1
3
/4
1

250

/4
1
3
/4
1

250

Wall Mount
Thru-Feed

400

400

VMVM2A250GP
VMVM3A250GP
N/A
N/A

VMVM2A250GR305
VMVM3A250GR305
VMVM2A400GR305
VMVM3A400GR305

VMVM2A250GRD4
VMVM3A250GRD4
VMVM2A400GRD4
VMVM3A400GRD4

VMVM2C250GP
VMVM3C250GP
N/A
N/A

VMVM2C250GR305
VMVM3C250GR305
VMVM2C400GR305
VMVM3C400GR305

VMVM2C250GRD4
VMVM3C250GRD4
VMVM2C400GRD4
VMVM3C400GRD4

VMVM2TW250GP
VMVM3TW250GP
N/A
N/A

VMVM2TW250GR305
VMVM3TW250GR305
VMVM2TW400GR305
VMVM3TW400GR305

Quad-Mount
Pendant, Adjustable
Thru-Feed, 25
Angle, 121/2 Angle

/4
/4

250
400

VMVM25Q250GP
N/A

VMVM25Q250GR305
VMVM25Q400GR305

VMVM25Q250GRD4
VMVM25Q400GRD4

Stanchion Mount
25 Angle

11/2

250

VMVMJ250GP

VMVMJ250GR305

VMVMJ250GRD4

11/2

400

N/A

VMVMJ400GR305

VMVMJ400GRD4

11/2
11/2

250
400

VMVMP250GP
N/A

VMVMP250GR305
VMVMP400GR305

3L

Stanchion Mount
Straight

* For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. VMVM2A250GR302
For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. VMVM2A250GR303
1. Add voltage suffix to end of catalog number
Standard Voltage Ballasts 60Hz
NEC/UL
Voltage
Suffix

Multi Tap
/MT

120V
/120

CEC/CSA (cUL)
480V
/480

Tri Tap
/TT

120V
/120

220V 60Hz
/220

220V 50Hz
/220 50

Optional Voltage Ballasts - 50 or 60Hz


CEC/CSA (cUL) - CWI Isolated Ballasts
Voltage
Suffix

208V CWI
/208CWI

240V CWI
/240CWI

600V CWI
/600CWI

EXPORT
230V 50Hz
/230 50

240V 50Hz
/240 50

2. Options - Add the required option suffixes, see page 951, in alpha-numeric order.

954

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

954-955.qxp

6/13/2011

10:18 AM

Page 955

3L

VMV High Wattage Series


Ordering by Components

VMV High Wattage Luminaires are available in components.


A complete luminaire consists of:
I.
II.
III.

Champ Cover (Mounting Module)


VMV Ballast Housing Include voltage and required option(s)
Optical & Guard Components Globe, Reflector, Refractor, Guard

I. Champ Cover (Mounting Module):


Type
Pendant

Conduit

Cat. #

/4"
1"

APM2
APM3

Ceiling

/4"
1"

CM2
CM3

Wall

/4"
1"

TWM2
TWM3

Stanchion 25 Degree Angle

11/2"

JM5

Stanchion Straight

11/2"

PM5

Quad-Mount

/4"

QM25

II. Ballast Housings:


Complete catalog number must have the voltage suffix (MT shown) and any options suffixes.
Lamp Type
High Pressure Sodium

Metal Halide

Lamp Watts

Cat. #

200
250
400
250
400

VMVS200/MT
VMVS250/MT
VMVS400/MT
VMVM250/MT
VMVM400/MT

III. Globe, Reflectors, Refractors, Guards:


Cat. #

Globe

G303

Globe Guard

P33

Reflector Dome

RD739

Reflector Angle

RA739

Refractor Type 2

GR302

Refractor Type 3

GR303

Refractor Type 5

GR305

Refractor Guard

P23

High Bay Reflector/Lens

GRD4

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

3L

Type

Copyright 2011 Cooper Crouse-Hinds

955

956-957.qxp

3L

5/30/2011

9:52 AM

Page 956

VMV High Wattage Series

Family Tree

3L

Champ H.I.D. Luminaires

956

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

VMV High Wattage Series

Temperature Performance Data

3L

Champ H.I.D. Luminaires

High Pressure Sodium


200

40
55
65

325 C 350 C
325 C 350 C
325 C 350 C

250

40
55
65

400

40
55

T2
T2
T2

T3
T3
T3

T4
T4

T3C

T1/T3C

T3C

75
75
85

350 C 350 C 325 C


350 C 350 C 350 C
350 C 350 C

T3
T3
T3

T4
T4

T3C

T1/T3C

T3C

75
85

350 C 350 C
350 C 350 C

T3
T3

T4
T4

T3C

T1/T3C

T3C

85
90

T1
T1

Metal Halide
40
55

350 C 325 C 350 C


350 C 350 C 350 C

T3
T3

T4
T4

T3B

350 C/T3B

T3B

85
90

250

40
55

350 C 325 C 350 C


350 C 350 C 350 C

T3
T3

T4
T4

T3B

350 C/T3B

T3B

85
90

400

40
55

T4

T3B

350 C/T3B

T3B

85

T3
T3

T4
T4

T3B

350 C/T3B

T3B

85
90

325 C
350 C

T1
T1

3L

200

Pulse Start Metal Halide (S828)


250

40
55

350 C 350 C 325 C


350 C 350 C 350 C

320

40

T1

325 C

T2A

T3

90

400

40

T1

T1

T1

T3

T4

90

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2012 Cooper Crouse-Hinds

957

958-959.qxp

5/30/2011

9:53 AM

Page 958

VMV High Wattage Series

3L

Dimensions & Weights

Champ H.I.D. Luminaires


Dimensions
In Inches:

Pendant Mount

Ceiling Mount

Wall Mount

25 Angle
Stanchion Mount

Luminaire with
Glass Refractor, Guard

3L

Quad-Mount

Luminaire with Etched Alzak


Reflector/Lens

Straight Stanchion Mount

Luminaire with Globe,


Guard, Reflectors

Net Luminaire Weights (lbs.):


Luminaire
Series
VMVS
VMVM

Lamp
Watts
200
250
400
250
400

Luminaire with:
Globe,
Reflector/
Guard (lbs.) Lens
291/2
291/2
381/2
321/2

30
30
39
33
34

Type
Lbs.
Type
Add for mounting modules:
Quad-Mount
Pendant
11/4
Angle Stanchion
Ceiling
23/4
Straight Stanchion
Wall
41/2
Add for reflectors:
30 Angle
Dome
11/2
High Bay
13/4
Deduct: 11/2 lb. for luminaire without P33 Guard
958

www.crouse-hinds.com

US: 1-866-764-5454

Glass
Refractor (lbs.)
321/2
321/2
411/2
353/4
351/2
Lbs.
31/2
31/2
41/2
11/2

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

958-959.qxp

5/30/2011

9:53 AM

Page 959

3L

Photometric Data

VMV High Wattage Series


Champ H.I.D. Luminaires

Lamp: 250W/E18 high pressure sodium (HPS)


Total bare lamp lumens: 27500
Note: All data provided is for high pressure sodium luminaires with 250W/E18 clear lamps. Use conversion factors (multipliers) shown below for other clear lamp types and wattages.
Consult Cooper Crouse-Hinds for additional photometric data on any Champ series luminaire.

Luminaire with Globe and Dome Reflector


Multipliers (for use with
candela curve only).
ConLuminaire Lamp version
Series
Watts Factor
VMVS

200
400

0.80
1.82

Luminaire spacing ratio: 2.0

Coefficient of Utilization
Effective Floor Cavity Reflectance 20%
% Reflectance
Eff. Ceil.
Wall

80

50
30
10

.750
.711
.677

.640
.582
.532

.550
.482
.429

.476
.402
.346

.416
.341
.285

70

50
30
10

.732
.696
.664

.625
.570
.526

.538
.474
.424

.465
.397
.343

.405
.335
.282

50

50
30
10

.695
.666
.641

.594
.549
.509

.513
.458
.414

.443
.384
.336

.388
.326
.279

30

50
30
10

.663
.640
.618

.567
.530
.496

.490
.443
.405

.423
.372
.330

.371
.316
.273

10

50
30
10

.635
.615
.597

.542
.510
.483

.469
.429
.395

.405
.360
.323

.355
.307
.268

.580

.464

.377

.251

10

80

50
30
10

.369
.295
.243

.327
.255
.208

.290
.222
.173

.263
.196
.150

.229
.163
.121

70

50
30
10

.360
.291
.239

.320
.251
.204

.285
.219
.172

.258
.193
.149

.224
.163
.121

50

50
30
10

.344
.283
.236

.306
.243
.200

.272
.213
.170

.247
.189
.147

.216
.159
.119

30

50
30
10

.330
.275
.233

.292
.238
.196

.262
.207
.167

.238
.183
.145

.207
.154
.116

10

50
30
10

.317
.267
.229

.282
.233
.194

.251
.202
.165

.229
.179
.142

.200
.150
.114

.212

.178

.149

.128

.101

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

3L

.305

Room Cavity Ratio


6
7
8

% Reflectance
Eff. Ceil.
Wall

www.crouse-hinds.com

Room Cavity Ratio


1
2
3

959

1000-1001.qxp

5/30/2011

10:13 AM

Page 1001

EVLP Low Profile HazardGard


(H.I.D.) Luminaires

Cl. I, Div. 1, Groups B


(GB suffix), C, D
Cl. I, Zone 1, Groups IIB + H2
(with suffix GB), IIB, IIA
Cl. II, Div. 1, Groups E, F, G;
Class III

Medium and Mogul Base

Marine & Wet


Locations
3, 3R, 4, 4X; IP66

4L

Applications:

Standard Materials:

Cooper Crouse-Hinds Low Profile


HazardGard luminaires are used in:
Areas where flammable or explosive
vapors or gases are present
Hazardous areas, both indoors and
outdoors, where long life and low
maintenance costs are desired
Petroleum refineries, chemical,
petrochemical and pharmaceutical
plants, oil terminals, gas plants and other
heavy process industry facilities
Waste treatment facilities
Drilling platforms and other coastal and
offshore hazardous areas

Mounting modules, cover, ballast


housing, globe holder copper-free
aluminum
Globe heat and impact resistant glass
Exterior hardware stainless steel
Reflectors (dome & angle) Krydon
fiberglass-reinforced polyester

Copper-free aluminum Corro-free


powdered epoxy
Krydon white
Stainless steel guard

Features and Benefits:

Ratings (Electrical/Size):
Certifications and
Compliances:
NEC and CEC:
Class I, Division 1, Groups B
(with suffix GB), C, D All Wattages
Class I, Zone 1, Groups IIB + H2
(with suffix GB), IIB, IIA All Wattages
Class II and Class III
UL Standards:
844, Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations
CSA Standards
C22.2 No. 137

Sources/Wattage:
Medium Base 70150W HPS, 70175W
MH
Mogul Base 70150W HPS, 70250W
MH
Voltages:
Medium & Mogul H.I.D.
120V 60Hz
Multi-tap (120, 208, 240, 277V 60Hz)
Tri-tap (120, 277, 347V 60Hz)
480V 60Hz
Other voltages consult Cooper
Crouse-Hinds
Conduit Entries:
3/4", 1" NPT pendant, wall bracket,
ceiling
11/4" NPT stanchion

Options:
Description
Suffix
Group B suitability ........................................................................................... GB
Ballast-Gard (HPS only) ................................................................................. BG
Instant restrike (Mogul Base only) ...................................................................
IR
70150W LX HPS
Cannot use with BG Option
Fused (not suitable for marine applications).................................................... S658*
Quartz auxiliary lighting
(Mogul Base only) ............................................................................................ QTZ
Cannot use with IR option
Uses 100W single ended double contract lamp
Quartz lamp not included
Factory assembled with lamps ........................................................................
FA

4L

Small, compact size is perfect where low


mounting restrictions are a concern.
Two start Acme threaded construction
allows for easier assembly, installation
and maintenance.
Lightweight copper-free aluminum
housing with powdered epoxy finish for
superior corrosion resistance.
All exterior hardware is corrosionresistant stainless steel.
Four mounting arrangements: pendant,
ceiling, wall bracket and stanchion suit
any lighting layout.
Wide range of light sources and
wattages to meet specific lighting needs.
Marine and NEMA 4X construction
suitable for outdoor, hose down, marine
and corrosive environments.
Integral ballast for lowest installed cost.
High power factor (90%+) ballasts allows
more fixtures per circuit.
Uses same mounting modules as the
standard HazardGard for easy
retrofitting when the Lo-Pro is the
preferred choice.
Internally fluted glass globe reduces
glare and distributes light evenly ideal
for adverse enviroments typical of
industrial facilities.
Krydon construction dome and angle
reflectors wont rust, corrode, dent,
chip or peel
Now available in components luminaire
body, mounting module, guard,
reflectors allowing for easy stocking for
Quick Ship requirements.

Standard Finishes:

*When ordering fuses for luminaires, option S658, you must specify the operating voltage.
S658 cannot be ordered with /MT in the catalog number.

Accessories:
Description

Cat. #

Dome reflector
Angle reflector

RD739
RA739

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

1001

1002-1003.qxp

4L

5/30/2011

10:13 AM

Page 1002

EVLP Low Profile


HazardGard

Marine & Wet Locations


3, 3R, 4, 4X; IP66

Cl. I, Div. 1, Groups B


(GB suffix), C, D
Cl. I, Zone 1, Groups IIB + H2
(with GB suffix), IIB, IIA
Cl. II, Div. 1, Groups E, F, G;
Class III

Medium Base
Ordering Information:

Pendant
Hub
With Guard
Watt Size (In.) Cat. #

Wall Bracket

Ceiling

Stanchion

Luminaire Body
Less Mounting
Module & Guard

With Guard
Cat. #

With Guard
Cat. #

With Guard
Cat. #

Cat. #

High Pressure Sodium


/4
1
11/4

EVLPA142071
EVLPA143071

EVLPBX142071
EVLPBX143071

EVLPCX142071
EVLPCX143071

/4
100W 1
11/4

EVLPA142101
EVLPA143101

EVLPBX142101
EVLPBX143101

EVLPCX142101
EVLPCX143101

/4
150W 1
11/4

EVLPA142151
EVLPA143151

EVLPBX142151
EVLPBX143151

EVLPCX142150
EVLPCX143151

70W
Pendant Mount

EVLP14070
EVLPJ144071
EVLP14100
EVLPJ144101
EVLP14151
EVLPJ144151

Pulse Start Metal Halide


3
/4
150W 1
11/4

EVLPA192151 S828 EVLPBX192151 S828 EVLPCX192151 S828


EVLPA193151 S828 EVLPBX193151 S828 EVLPCX193151 S828

/4
175W 1
11/4

EVLPA192171 S828 EVLPBX192171 S828 EVLPCX192171 S828


EVLPA193171 S828 EVLPBX193171 S828 EVLPCX193171 S828

Wall Bracket
Mount

EVLP19150 S828
EVLPJ194151 S828
EVLP19175 S828
EVLPJ194171 S828

Metal Halide
3
/4
1
11/4

EVLPA192071
EVLPA193071

/4
100W 1
11/4

EVLPA192101
EVLPA193101

/4
175W 1
11/4

EVLPA192171
EVLPA193171

70W

4L

EVLPBX192071
EVLPBX193071

EVLPCX192071
EVLPCX193071

EVLP19070
EVLPJ194071

EVLPBX192101
EVLPBX193101

EVLPCX192101
EVLPCX193101

EVLP19100
EVLPJ194101

EVLPBX192171
EVLPBX193171

EVLPCX192171
EVLPCX193171

EVLP19175
EVLPJ194171

Ceiling Mount

Complete Catalog Number as follows:


Standard Voltage Ballasts 60Hz
1.

NEC/UL
Voltage
Suffix

Multi Tap
/MT

120V
/120

CEC/CSA (cUL)
480V
/480

Tri Tap
/TT

120V
/120

Optional Voltage Ballasts 50 or 60Hz


*CEC/CSA (cUL) CWI Isolated Ballasts
Voltage
Suffix

208V CWI
/208CWI

240V CWI
/240CWI

EXPORT

600V CWI
/600CWI

220V 60Hz
/220

220V 50Hz
/220 50

2. 150W HPS Luminaires only

Stanchion Mount

55V lamps add suffix "LX"


100V lamps add suffix "CE"

Ceiling and bracket mounts have 4 hubs: 3 are plugged.


*CWI Isolated Ballasts are only available for high pressure sodium and 175W metal halide (non pulse start) luminaires.

1002

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

230V 50Hz
/230 50

240V 50Hz
/240 50

1002-1003.qxp

5/30/2011

10:13 AM

Page 1003

EVLP Low Profile


HazardGard

Cl. I, Div. 1, Groups B (GB suffix), C, D


Cl. I, Zone 1, Groups IIB + H2
(with GB suffix), IIB, IIA
Cl. II, Div. 1, Groups E, F, G; Class III

Mogul Base

4L

Marine & Wet Locations


3, 3R, 4, 4X; IP66

Ordering Information:

Pendant
With
Guard
Hub
Watt Size(In.) Cat. #

Wall Bracket
With Guard
Cat. #

Ceiling
With Guard
Cat. #

Stanchion
With Guard
Cat. #

Luminaire Body
Less Mounting
Module & Guard
Cat. #

High Pressure Sodium


3
/4
1
11/4

EVLPA042071
EVLPA043071

EVLPBX042071
EVLPBX043071

EVLPCX042071
EVLPCX043071

/4
100W 1
11/4

EVLPA042101
EVLPA043101

EVLPBX042101
EVLPBX043101

EVLPCX042101
EVLPCX043101

/4
150W 1
11/4

EVLPA042151
EVLPA043151

EVLPBX042151
EVLPBX043151

EVLPCX042151
EVLPCX043151

70W

EVLPJ044071

Pendant Mount

EVLP04070

EVLP04100
EVLPJ044101

EVLP04150
EVLPJ044151

Pulse Start Metal Halide


3
/4
150W 1
11/4

EVLPA092151S828 EVLPBX092151S828 EVLPCX092151S828


EVLPA093151S828 EVLPBX093151S828 EVLPCX093151S828

/4
175W 1
11/4

EVLPA092171S828 EVLPBX092171S828 EVLPCX092171S828


EVLPA093171S828 EVLPBX093171S828 EVLPCX093171S828

/4
200W 1
11/4

EVLPA092201S828 EVLPBX092201S828 EVLPCX092201S828


EVLPA093201S828 EVLPBX093201S828 EVLPCX093201S828

/4
250W 1
11/4

EVLPA092251S828 EVLPBX092251S828 EVLPCX092251S828


EVLPA093251S828 EVLPBX093251S828 EVLPCX093251S828

EVLPJ094151S828

EVLP09170S828
EVLPJ094171S828

Wall Bracket
Mount

EVLP09150S828

EVLP09201S828
EVLPJ094201S828

EVLP09250S828
EVLPJ094251S828

Metal Halide
3
/4
1
11/4

EVLPA092071
EVLPA093071

/4
100W 1
11/4

EVLPA092101
EVLPA093101

EVLPBX092101
EVLPBX093101

EVLPCX092101
EVLPCX093101

/4
175W 1
11/4

EVLPA092171
EVLPA093171

EVLPBX092171
EVLPBX093171

EVLPCX092171
EVLPCX093171

/4
250W 1
11/4

EVLPA092251
EVLPA093251

70W

Ceiling Mount

EVLPCX092071
EVLPCX093071

EVLP09070
EVLPJ094071
EVLP09100
EVLPJ094101

4L

EVLPBX092071
EVLPBX093071

EVLP09170
EVLPJ094171

EVLPBX092251
EVLPBX093251

EVLPCX092251
EVLPCX093251

EVLP09250
EVLPJ094251

Complete Catalog Number as follows:


Standard Voltage Ballasts 60Hz
1.
Voltage
Multi Tap
Suffix
/MT

NEC/UL
120V
/120

CEC/CSA (cUL)
480V
/480

Tri Tap
/TT

Optional Voltage Ballasts 50 or 60Hz


*CEC/CSA (cUL) CWI Isolated Ballasts
Voltage
Suffix

Stanchion Mount

208V CWI
/208CWI

240V CWI
/240CWI

600V CWI
/600CWI

120V
/120

EXPORT
220V 60Hz
/220

220V 50Hz
/220 50

230V 50Hz
/230 50

240V 50Hz
/240 50

2. 150W HPS Luminaires only


55V lamps add suffix "LX"
100V lamps add suffix "CE"
Example: EVLPA043151/MT-LX

Ceiling and wall bracket mounts have 4 hubs: 3 are plugged.


*CWI Isolated Ballasts are only available for high pressure sodium and 175W250W metal halide (non pulse start) luminaires.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

1003

1004-1005.qxp

5/30/2011

10:14 AM

Page 1004

EVLP Low Profile


HazardGard

4L

Ordering by Components
EVLP Luminaires are available in components.
A

complete luminaire consists of:


Mounting Module
Luminaire Body
Guard, Dome Reflector or Angle Reflector

Mounting Modules:
Type
Pendant

Conduit

Cat. #

/4"
1"

EVMP2
EVMP3

/4"
1"

EV22
EV33

Ceiling & Wall Box


Wall Bracket Arm

Use EV22 or EV33 box with EV87

EV87

Stanchion

11/4"

EVMJ4

Guards
Medium
Mogul

EV511
EV512

Reflectors
Dome
Angle

RD739
RA739
Pendant

Ceiling

Stanchion

Ceiling

Wall Bracket

EVMP2
EVMP3

EV22
EV33

EVMJ4

EV22
EV33

EV87 & EV22 or EV33

4L

Luminaire Body
EVLP0 Series H.I.D. Mogul Lamp
EVLP1 Series H.I.D. Medium Lamp

1004

Guards

Dome Reflector

Angle Reflector

EV511
EV512

RD739

RA739

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

1004-1005.qxp

5/30/2011

10:14 AM

Page 1005

4L

Temperature Performance Data

EVLP Low Profile


HazardGard

Medium Base Lamp Luminaires:

Maximum Ambient

Watts

Class I, Group B
(w/GB suffix)
Groups C, D
40C
55C

65C

Class II, Groups E, F, G


Class III
Simultaneous
Presence
40C

High Pressure Sodium

70W
100W
150W

T5
T4A
T4

T4A
T4A
T3C

T4A
T4

T4A
T4

90C
90C
90C

Metal Halide
(including pulse start)

70W
100W
150W
175W

T5
T3C
T3C
T3C

T4A
T3C
T3B
T3B

T4A

T4

85C
90C
90C
90C

Supply Wire C

Mogul Base Lamp Luminaires:


Class II, Groups E, F, G
Class III
Simultaneous
Presence

Class I, Group B
(w/GB suffix)
Groups C, D
Maximum Ambient

Watts

40C

55C

65C

40C

Supply Wire C

High Pressure Sodium

70W
100W
150W

T6
T5
T4A

T5
T4A
T4

T5

T5
T4A
T4

90C
90C
90C

Metal Halide
(including pulse start)

70W
100W
150W
175W
200W
250W

T6
T5
T4
T4
T3C
T3C

T5
T4A
T3C
T3C

T5
T4A

T5
T4A
T3C
T3C

85C
90C
90C
90C
90C
90C

4L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

1005

1006-1007.qxp

5/30/2011

4L

10:16 AM

Page 1006

EVLP Low Profile


HazardGard
Dimensions and Weights

Dimensions
In Inches:

4L

Medium Base
Mogul Base

13.92
15.69

12.73
14.69

16.50
18.25

16.71
18.46

20.59
22.34

19.36
21.30

Weights
(lbs.):
Luminaire w/guard
Source
High Pressure Sodium

Watts

Medium

Mogul

70
100
150

34
36
36.5

36.5
38.5
39

70
100
150
175
200
250

33.5
34.5
36
36

36
37
38.5
38.5
40.5
40.5

Metal Halide

Medium

Mogul

Add Mounting Modules:


Pendant
Ceiling
Bracket
Stanchion

1
2
4.5
2.5

1
2
4.5
2.5

Add For Reflectors:


RA739
RD739
Deduct for Wire Guard

1
1
0.5

1
1
0.5

1006

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

1006-1007.qxp

5/30/2011

10:16 AM

Page 1007

Photometric Data

EVLP Low Profile


HazardGard

4L

Medium Base
Medium Base
Luminaire with Globe and Guard
EVLPA143151 Lamp: 150W/B17 High Pressure Sodium (HPS)

Medium Base
Luminaire with Globe and Dome Reflector (Less Guard)
EVLPA143150RD Lamp: 150W/B17 High Pressure Sodium (HPS)

4L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

1007

1008-1009.qxp

5/30/2011

4L

10:16 AM

Page 1008

Photometric Data

EVLP Low Profile


HazardGard
Medium and Mogul Base

Medium Base
Luminaire with Globe and 30 Angle Reflector (Less Guard)
EVLPA143150RA Lamp: 150W/B17 High Pressure Sodium (HPS)

Mogul Base
Luminaire with Globe and Guard
4L

EVLPA043151 Lamp: 150W/E23-1/2 High Pressure Sodium (HPS)

1008

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

1008-1009.qxp

5/30/2011

10:16 AM

Page 1009

EVLP Low Profile


HazardGard

4L

Photometric Data

Mogul Base
Mogul Base
Luminaire with Globe and Dome Reflector (Less Guard)
EVLPA043150RD Lamp: 150W/E23-1/2 High Pressure Sodium (HPS)

Mogul Base
Luminaire with Globe and 30 Angle Reflector (Less Guard)
EVLPA043150RA Lamp: 150W/E23-1/2 High Pressure Sodium (HPS)

4L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

1009

1010-1011.qxp

5/30/2011

4L

10:17 AM

Page 1010

Photometric Data

EVLP Low Profile


HazardGard
Mogul Base

Mogul Base
Luminaire with Globe and Guard
EVLPA093171 Lamp: 175W/ED28 Metal Halide (MH)

Mogul Base
Luminaire with Globe and Dome Reflector (Less Guard)
4L

EVLPA093170RD Lamp: 175W/ED28 Metal Halide (MH)

1010

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

1010-1011.qxp

5/30/2011

10:17 AM

Page 1011

4L

Photometric Data

EVLP Low Profile


HazardGard
Mogul Base
Mogul Base

Luminaire with Globe and 30 Angle Reflector (Less Guard)


EVLPA093170RA Lamp: 175W/ED28 Metal Halide (MH)

4L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

1011

984-985.qxp

5/30/2011

10:03 AM

Page 985

EVLS HazardGard
Compact & Rugged, Class I, Zone 1,
Div. 1 Explosionproof Luminaire

Cl. I, Div. 1, Group B


(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III & Simultaneous Presence

Introducing a compact, affordable,


explosionproof luminaire that has the best
overall temperature performance ratings in
its class!
Cooper Crouse-Hinds EVLS HazardGard
is perfect as a general area lighting
workhorse where space constraints exist.
EVLS HazardGard is easy to install, 175
watts and less, has select options that are
just right for your budget AND its
Class I, Division 1, Group B with GB option!

Standard Materials:

Applications:

Ratings (Electrical Size):

Cooper Crouse-Hinds EVLS HazardGard


Lighting Fixures are used for general
lighting and task lighting in:
Areas where flammable or explosive
vapors or gases are present
Confined spaces or heavy process
industry facilities
Petroleum refineries; chemical,
petrochemical and pharmaceutical
plants; oil terminals; gas plants
Waste treatment facilities
Drilling platforms and other coastal and
offshore hazardous areas

Features:

Certification &
Compliances:

4L

Bodies, mounting modules and cast


guards copper-free aluminum
Wire guard stainless steel
Globe heat- and impact-resistant glass
Gaskets silicone and neoprene

Standard Finishes:
Epoxy powder coat paint

Sources/Wattages:
HID Medium Base (initial offering)
HPS: 50, 70, 100, 150 watt
Metal Halide: 70, 100, 175 watt
Pulse Start Metal Halide: 150, 175 watt
Voltages:
Multi-tap (120, 208, 240, 277V/60 Hz)
480V/60 Hz
Tri-tap (120, 277, 347V/60 Hz)
220V/60 Hz
220/240V (or 230V)/50 Hz
Transformer Types:
HX-HPF Standard
CWA Standard on 175W
CWA Constant Wattage Autotransformer
CWI Constant Wattage Insulation
Transformer
Available for HPS and MH, for most
voltages and wattages (Additional
voltages available on request.)
Conduit Entries:
3/4" and 1" NPT pendant, ceiling and
wall mount
11/2" NPT stanchion

Two Start Acme Threads

4L

Compact and rugged - a Division 1


luminaire that fits in tight spaces
Smooth turning two start Acme threads
for mounting modules and globe
attachments save time and eliminate
installation damage
Quick-connect design facilitates easy
installation and saves money - install and
wire the mounting module, and then
screw in luminaire to make the electrical
connection
Best overall T-rating in the industry for a
medium-base HID lamp - use in elevated
ambient and illuminate the most volatile
areas of your facility - optimal safety in
your high-risk areas
Factory-sealed - wired and sealed with
no external sealing fittings required in
Groups B, C, and D
An adapter module is available for direct
connection to existing HazardGard
modules such as the EV22 ceiling mount

UL and cUL Listed


Wet locations (UL1598)
Marine locations (UL1598A)
Type 4X, IP66

Options:
Description
Instant Restrike (HPS)
Ballast-Gard (HPS)
Group B Suitability

Suffix
IR
BG
GB

Accessories:
Description
Dome Reflector
Angle Reflector
Guard

Suffix
RD725
RA725
EV502 or P515

UL (844) and cUL Listed (CSA C22.2


No. 137) for:
Class I, Division 1, Groups B (with suffix
GB), C, D
Class I, Zone 1, Group IIB + H2 (with
suffix GB)
Class II, Class III & Simultaneous
Presence
Wet locations (UL1598), Marine locations
(UL1598A), Type 4X, IP66

www.crouse-hinds.com

Quick Connect Design

Adapter Module Available

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

985

986-987.qxp

5/30/2011

10:04 AM

Page 986

4L EVLS HazardGard

Cl. I, Div. 1, Groups B


(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Compact & Rugged, Class I, Zone 1, Cl. II, Cl. III & Simultaneous Presence

UL and cUL Listed


Wet locations (UL1598),
Marine locations (UL1598A)
Type 4X, IP66

Div. 1 Explosionproof Luminaire


Mounting Modules:

New Mounting Modules

Existing For EVI, EVLP, EVM (must use EVSA adapter)


Conduit
Catalog Number

Type
Adapter
Pendant

"
1"

EVSA
EVMP2
EVMP3

Ceiling & Wall Box

"
1"

EV22
EV33

Wall Bracket Arm

Use EV22 or EV33 box with

EV87

Stanchion
Bulkhead

1"
1"

EVMJ4
EVJ2

Conduit
"
1"
25mm
32mm
"
1"
25mm
32mm
"
1"
25mm
32mm
1"
"
25mm

For EVLS Only


Catalog Number
EVSP2
EVSP3
EVSP25
EVSP32
EVSC2
EVSC3
EVSC25
EVSC32
EVSW2
EVSW3
EVSW25
EVSW32
EVSJ5
EVSB2
EVSB25

Family Tree:
Existing Mounting
Modules used on
EVI, EVLP, EVM
(must use EVSA adapter)
EVMP2
EVMP3

EV22
EV33

EVMJ4

EVJ2
EV22
EV33

EV87

EVSA ADAPTER
EVSJ5

4L

New Mounting
Modules for EVLS

EVSC2
EVSC3
EVSC25
EVSC32

EVSB2
EVSB25

EVSP2
EVSP3
EVSP25
EVSP32

EVSW2
EVSW3
EVSW25
EVSW32

EVLS (For example: EVLS9170)

RA725

RD725

EV502

986

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

P515

Copyright 2011 Cooper Crouse-Hinds

986-987.qxp

5/30/2011

10:04 AM

Page 987

EVLS HazardGard

UL and cUL Listed


4L
Wet locations (UL1598),
Marine locations (UL1598A)
Type 4X, IP66

Cl. I, Div. 1, Groups B


(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III & Simultaneous Presence

Compact & Rugged, Class I, Zone 1,


Div. 1 Explosionproof Luminaire
Ordering Reference Sheet:
EVLS

HazardGard
Low-Profile Luminaire
Class I, Div. 1/Class I, Zone 1
Class II, Groups F & G

10

/MT

-IR

A = Pendant
Mounting Type
BX = Wall
CX = Ceiling
BH = Bulkhead
J = Stanchion
M = Mounting Module Adapter
4 = High-Press. Sodium
9 = Metal Halide

Lamp Type

Conduit Entry (specify with mtg. modules)


2 = 3/4" NPT (Pendant, Ceiling, Bulkhead & Wall mounts only)
3 = 1" NPT (Pendant, Ceiling & Wall mounts only)
5 = 1-1/2" NPT (Stanchion only)
25 = 25 mm (Pendant, Ceiling, Bulkhead & Wall mounts only)
32 = 32 mm (Pendant, Ceiling & Wall mounts only)
Note: Omit for mounting module adapter
05 = 50W HPS
07 = 70W HPS, MH
10 = 100W HPS, MH
15 = 150 HPS, MH Pulse Start
17 = 175W MH, MH Pulse Start
0 = globe only, no guard
1 = stainless steel wire guard
2 = cast aluminum guard

Lamp Wattage
by lamp type

Guard
(optional)
Voltage and Frequency
HPS
70

100

150

70

100

150 PS

MT

TT

DT

120

175 PS

208
220
220 50

175

4L

50

MH

240

240 50

277

347

480

BG = Ballast Guard (lamp type S only)


CWI = SCE Ballast
GB = Group B suitability
IR = Instant Restrike (lamp type S only)
S828 = Pulse Start (175W & 150W MH only)

x
x

Options

Note: BG and IR options cannot be installed together.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

987

988-989.qxp

5/30/2011

10:05 AM

Page 988

4L EVLS HazardGard

Cl. I, Div. 1, Groups B


(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Compact & Rugged, Class I, Zone 1, Cl. II, Cl. III & Simultaneous Presence

UL and cUL Listed


Wet locations (UL1598),
Marine locations (UL1598A)
Type 4X, IP66

Div. 1 Explosionproof Luminaire


Temperature Performance Data:
Watts
Ambient Temp C
High Pressure Sodium

Class I,
Div. 1 & Zone 1

Class II
(Dust) and Class III

Supply Wire Temp C

T5
T4A
T4A
T5
T4A
T4A
T4A
T4
T4
T4A
T4

T5

T5

T3C

T3C

90
90
105
90
90
105
90
90
105
90
90

T4A

T4

90
90
105
90
90
105
90
90
90

40
55
65
40
55
65
40
55
65
40
55

50W

70W

100W

150W

Metal Halide (including Pulse Start [PS] as indicated)


40
55
65
40
55
65
40
40
40

70W

100W
150 PS
175W
175 PS

T5
T4A
T4A
T4A
T4A
T4
T3C
T3C
T3C

Net Luminaire Weights (lbs.):


Luminaire Series
High Pressure Sodium
EVLS4

Lamp Watts

Weight with Globe &


Wire Guard
18.5
21.5
22.5
24

70W
100W
150 PS
175W
175 PS

Add for cast guard:

20
20.5
23
23
23
1

Add for mounting modules:


Pendant
Ceiling
Stanchion
Bulkhead
Wall
Adapter

2
3.5
3
2.5
5.5
2

Add for reflectors:


Dome
Angle

1.5
2

4L

50W
70W
100W
150W

Metal Halide
EVLS9

988

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

988-989.qxp

5/30/2011

10:06 AM

Page 989

EVLS HazardGard
Compact & Rugged, Class I,
Zone 1, Div. 1 Explosionproof Luminaire

Cl. I, Div. 1, Groups B


(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2 (with
suffix GB)
Cl. II, Cl. III & Simultaneous Presence

UL and cUL Listed


4L
Wet locations (UL1598),
Marine locations (UL1598A)
Type 4X, IP66

Ordering Information High Pressure Sodium:

Wattage

Hub Size

No Guard

PENDANT
Wire Guard

Cast Guard

No Guard

BULKHEAD
Wire Guard

Cast Guard

/4"
1"
11/2"
25 mm
32 mm
3
/4"
1"
11/2"
25 mm
32 mm
3
/4"
1"
11/2"
25 mm
32 mm
3
/4"
1"
11/2"
25 mm
32 mm

EVLSA42050
EVLSA43050

EVLSA42051
EVLSA43051

EVLSA42052
EVLSA43052

EVLSBH42050

EVLSBH42051

EVLSBH42052

EVLSA425050
EVLSA432050
EVLSA42070
EVLSA43070

EVLSA425051
EVLSA432051
EVLSA42071
EVLSA43071

EVLSA425052
EVLSA432052
EVLSA42072
EVLSA43072

EVLSBH425050

EVLSBH425051

EVLSBH425052

EVLSBH42070

EVLSBH42071

EVLSBH42072

EVLSA425070
EVLSA432070
EVLSA42100
EVLSA43100

EVLSA425071
EVLSA432071
EVLSA42101
EVLSA43101

EVLSA425072
EVLSA432072
EVLSA42102
EVLSA43102

EVLSBH425070

EVLSBH425071

EVLSBH425072

EVLSBH42100

EVLSBH42101

EVLSBH42102

EVLSA425100
EVLSA432100
EVLSA42150
EVLSA43150

EVLSA425101
EVLSA432101
EVLSA42151
EVLSA43151

EVLSA425102
EVLSA432102
EVLSA42152
EVLSA43152

EVLSBH425100

EVLSBH425101

EVLSBH425102

EVLSBH42150

EVLSBH42151

EVLSBH42152

EVLSA425150
EVLSA432150

EVLSA425151
EVLSA432151

EVLSA425152
EVLSA432152

EVLSBH425150

EVLSBH425151

EVLSBH425152

50W

70W

100W

150W

Complete
Standard Voltage Ballasts
catalog
number
as follows: NEC/UL

CEC/CSA (cUL)

Export

Multi-tap

120V

480V

Suffix

/MT

/120

/480

/TT

/120

www.crouse-hinds.com

/208CWI

240V
CWI

480V
CWI

600V
CWI

220V
60 Hz

220V
50 Hz

240V
50 Hz

/240CWI

/480CWI

/600CWI

/220

/220 50

/240 50

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

4L

Voltage

Tri-Tap 120V 208V


CWI

989

4L EVLS HazardGard

Cl. I, Div. 1, Groups B


(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Compact & Rugged, Class I, Zone 1, Cl. II, Cl. III & Simultaneous Presence

UL and cUL Listed


Wet locations (UL1598),
Marine locations (UL1598A)
Type 4X, IP66

Div. 1 Explosionproof Luminaire

Ordering Information High Pressure Sodium (Cont'd):

Wattage

/4"
1"
11/2"
25 mm
32 mm
3
/4"
1"
11/2"
25 mm
32 mm
3
/4"
1"
11/2"
25 mm
32 mm
3
/4"
1"
11/2"
25 mm
32 mm
3

50W

70W

100W

4L

150W

WALL
Wire Guard

Cast Guard

No Guard

CEILING
Wire Guard

Cast Guard

EVLSBX42050
EVLSBX43050

EVLSBX42051
EVLSBX43051

EVLSBX42052
EVLSBX43052

EVLSCX42050
EVLSCX43050

EVLSCX42051
EVLSCX43051

EVLSCX42052
EVLSCX43052

EVLSBX425050
EVLSBX432050
EVLSBX42070
EVLSBX43070

EVLSBX425051
EVLSBX432051
EVLSBX42071
EVLSBX43071

EVLSBX425052
EVLSBX432052
EVLSBX42072
EVLSBX43072

EVLSCX425050
EVLSCX432050
EVLSCX42070
EVLSCX43070

EVLSCX425051
EVLSCX432051
EVLSCX42071
EVLSCX43071

EVLSCX425052
EVLSCX432052
EVLSCX42072
EVLSCX43072

EVLSBX425070
EVLSBX432070
EVLSBX42100
EVLSBX43100

EVLSBX425071
EVLSBX432071
EVLSBX42101
EVLSBX43101

EVLSBX425072
EVLSBX432072
EVLSBX42102
EVLSBX43102

EVLSCX425070
EVLSCX432070
EVLSCX42100
EVLSCX43100

EVLSCX425071
EVLSCX432071
EVLSCX42101
EVLSCX43101

EVLSCX425072
EVLSCX432072
EVLSCX42102
EVLSCX43102

EVLSBX425100
EVLSBX432100
EVLSBX42150
EVLSBX43150

EVLSBX425101
EVLSBX432101
EVLSBX42151
EVLSBX43151

EVLSBX425102
EVLSBX432102
EVLSBX42152
EVLSBX43152

EVLSCX425100
EVLSCX432100
EVLSCX42150
EVLSCX43150

EVLSCX425101
EVLSCX432101
EVLSCX42151
EVLSCX43151

EVLSCX425102
EVLSCX432102
EVLSCX42152
EVLSCX43152

EVLSBX425150
EVLSBX432150

EVLSBX425151
EVLSBX432151

EVLSBX425152
EVLSBX432152

EVLSCX425150
EVLSCX432150

EVLSCX425151
EVLSCX432151

EVLSCX425152
EVLSCX432152

Hub Size No Guard

Complete
Standard Voltage Ballasts
catalog
number
as follows: NEC/UL
CEC/CSA (cUL)
208V
Voltage
Multi-tap 120V 480V Tri-Tap 120V
CWI

240V
CWI

480V
CWI

600V
CWI

Suffix

/240CWI

/480CWI

/600CWI /220

990

/MT

/120

/480

www.crouse-hinds.com

/TT

/120

US: 1-866-764-5454

/208CWI

CAN: 1-800-265-0502

Export
220V
60 Hz

Copyright 2012 Cooper Crouse-Hinds

220V
50 Hz

240V
50 Hz

/220 50

/240 50

990-991.qxp

5/30/2011

10:07 AM

Page 991

EVLS HazardGard

Cl. I, Div. 1, Groups B


(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III & Simultaneous Presence

Compact & Rugged, Class I, Zone 1,


Div. 1 Explosionproof Luminaire

UL and cUL Listed


4L
Wet locations (UL1598),
Marine locations (UL1598A)
Type 4X, IP66

Ordering Information High Pressure Sodium (Cont'd):

ADAPTER

STANCHION

Wattage Hub Size


50W
70W
100W
150W

Adapter
11/2"
Adapter
11/2"
Adapter
11/2"
Adapter
11/2"

No Guard

Wire Guard

Cast Guard

EVLSJ45050

EVLSJ45051

EVLSJ45052

EVLSJ45070

EVLSJ45071

EVLSJ45072

EVLSJ45100

EVLSJ45101

EVLSJ45102

EVLSJ45150

EVLSJ45151

EVLSJ45152

No Guard

Wire Guard

Cast Guard

Luminaire less
mounting module
and guard

EVLSM4050

EVLSM4051

EVLSM4052

EVLS4050

EVLSM4070

EVLSM4071

EVLSM4072

EVLS4070

EVLSM4100

EVLSM4101

EVLSM4102

EVLS4100

EVLSM4150

EVLSM4151

EVLSM4152

EVLS4100

Complete
STANDARD VOLTAGE BALLASTS
catalog
number as
NEC/UL
CEC/CSA (cUL)
follows:
Voltage

Multi-tap 120V 480V

Tri-Tap 120V 208V


CWI

Suffix

/MT

/TT

/120

/480

/120

Export

/208CWI

240V
CWI

480V
CWI

600V
CWI

220V
60 Hz

/240CWI

/480CWI

/600CWI /220

220V
50 Hz

240V
50 Hz

/220 50

/240 50

4L

Photometrics - EVLS High Pressure Sodium


Fixture with Globe and Domed Reflector (less guard) EVLSA42150RD725
Lamp: 150W/B17 High Pressure Sodium (HPS)

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

991

992-993.qxp

5/30/2011

10:08 AM

Page 992

4L EVLS HazardGard
Compact & Rugged, Class I, Zone 1,
Div. 1 Explosionproof Luminaire

Cl. I, Div. 1, Groups B


(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III & Simultaneous Presence

Photometrics - EVLS High Pressure Sodium:


Fixture with Globe and Guard EVLSA42151
Lamp: 150W/B17 High Pressure Sodium (HPS)

Photometrics - EVLS High Pressure Sodium:

4L

Fixture with Globe and Angled Reflector (less guard) EVLSA42150RA725


Lamp: 150W/B17 High Pressure Sodium (HPS)

992

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

UL and cUL Listed


Wet locations (UL1598),
Marine locations (UL1598A)
Type 4X, IP66

992-993.qxp

5/30/2011

10:08 AM

Page 993

EVLS HazardGard
Compact & Rugged, Class I, Zone 1,
Div. 1 Explosionproof Luminaire

Cl. I, Div. 1, Groups B


(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III & Simultaneous Presence

UL and cUL Listed


4L
Wet locations (UL1598),
Marine locations (UL1598A)
Type 4X, IP66

Ordering Information Pulse Start Metal Halide:

Wattage Hub
Size

150W

175W

3/4"
1"
11/2"
25 mm
32 mm
3
/4"
1"
11/2"
25 mm
32 mm

No Guard

PENDANT
Wire Guard

Cast Guard

No Guard

BULKHEAD
Wire Guard

Cast Guard

EVLSA92150-S828
EVLSA93150-S828

EVLSA92151-S828
EVLSA93151-S828

EVLSA92152-S828
EVLSA93152-S828

EVLSBH92150-S828

EVLSBH92151-S828

EVLSBH92152-S828

EVLSA925150-S828
EVLSA932150-S828
EVLSA92170-S828
EVLSA93170-S828

EVLSA925151-S828
EVLSA932151-S828
EVLSA92171-S828
EVLSA93171-S828

EVLSA925152-S828
EVLSA932152-S828
EVLSA92172-S828
EVLSA93172-S828

EVLSBH925150-S828 EVLSBH925151-S828

EVLSBH925152-S828

EVLSBH92170-S828

EVLSBH92172-S828

EVLSA925170-S828 EVLSA925171-S828 EVLSA925172-S828


EVLSA932170-S828 EVLSA932171-S828 EVLSA932172-S828

EVLSBH925170-S828 EVLSBH925171-S828

EVLSBH92171-S828

EVLSBH925172-S828

Ordering Information Pulse Start Metal Halide:

4L

Wattage Hub
Size
3
/4"
1"
11/2"
150W
25 mm
32 mm
3
/4"
1"
175W
11/2"
25 mm
32 mm

No Guard

WALL
Wire Guard

Cast Guard

No Guard

CEILING
Wire Guard

EVLSBX92150-S828
EVLSBX93150-S828

EVLSBX92151-S828
EVLSBX93151-S828

EVLSBX92152-S828
EVLSBX93152-S828

EVLSCX92150-S828
EVLSCX93150-S828

EVLSCX92151-S828 EVLSCX92152-S828
EVLSCX93151-S828 EVLSCX93152-S828

EVLSBX925150-S828
EVLSBX932150-S828
EVLSBX92170-S828
EVLSBX93170-S828

EVLSBX925151-S828
EVLSBX932151-S828
EVLSBX92171-S828
EVLSBX93171-S828

EVLSBX925152-S828
EVLSBX932152-S828
EVLSBX92172-S828
EVLSBX93172-S828

EVLSCX925150-S828
EVLSCX932150-S828
EVLSCX92170-S828
EVLSCX93170-S828

EVLSCX925151-S828
EVLSCX932151-S828
EVLSCX92171-S828
EVLSCX93171-S828

Cast Guard

EVLSCX925152-S828
EVLSCX932152-S828
EVLSCX92172-S828
EVLSCX93172-S828

EVLSBX925170-S828 EVLSBX925171-S828 EVLSBX925172-S828 EVLSCX925170-S828 EVLSCX925171-S828 EVLSCX925172-S828


EVLSBX932170-S828 EVLSBX932171-S828 EVLSBX932172-S828 EVLSCX932170-S828 EVLSCX932171-S828 EVLSCX932172-S828

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

993

994-995.qxp

5/30/2011

10:09 AM

Page 994

4L EVLS HazardGard
Compact & Rugged, Class I, Zone 1,
Div. 1 Explosionproof Luminaire

Cl. I, Div. 1, Groups B


(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III & Simultaneous Presence

UL and cUL Listed


Wet locations (UL1598),
Marine locations (UL1598A)
Type 4X, IP66

Ordering Information Pulse Start Metal Halide (Cont'd):

STANCHION

4L

Hub
Wattage Size
Adapter
3
/4"
1"
150W
11/2"
25 mm
32 mm
Adapter
3
/4"
1"
175W
11/2"
25 mm
32 mm

No Guard

Wire Guard

ADAPTER

Cast Guard

Wire Guard

Cast Guard

EVLSM9150-S828 EVLSM9151-S828 EVLSM9152-S828 EVLS9150-S828

EVLSJ95150-S828 EVLSJ95151-S828 EVLSJ95152-S828

EVLSM9170-S828 EVLSM9171-S828 EVLSM9172-S828 EVLS9100-S828


EVLS9170-S828
EVLSJ95170-S828 EVLSJ95171-S828 EVLSJ95172-S828

Complete
catalog
Standard Voltage Ballasts
number as
NEC/UL
follows:
Multi-tap
120V
Voltage

480V

Suffix

/480

994

No Guard

Luminaire
less
mounting
module and
guard

/MT

www.crouse-hinds.com

/120

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

994-995.qxp

5/30/2011

10:09 AM

Page 995

EVLS HazardGard

Cl. I, Div. 1, Groups B


(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III & Simultaneous Presence

Compact & Rugged, Class I, Zone 1,


Div. 1 Explosionproof Luminaire

UL and cUL Listed


4L
Wet locations (UL1598),
Marine locations (UL1598A)
Type 4X, IP66

Ordering Information Metal Halide:

PENDANT
Wattage

70W

100W

175W

Hub Size
3
/4"
1"
11/2"
25 mm
32 mm
3
/4"
1"
11/2"
25 mm
32 mm
3
/4"
1"
11/2"
25 mm
32 mm

BULKHEAD

No Guard
EVLSA92070
EVLSA93070

Wire Guard
EVLSA92071
EVLSA93071

Cast Guard
EVLSA92072
EVLSA93072

No Guard
EVLSBH92070

Wire Guard
EVLSBH92071

Cast Guard
EVLSBH92072

EVLSA925070
EVLSA932070
EVLSA92100
EVLSA93100

EVLSA925071
EVLSA932071
EVLSA92101
EVLSA93101

EVLSA925072
EVLSA932072
EVLSA92102
EVLSA93102

EVLSBH925070

EVLSBH925071

EVLSBH925072

EVLSBH92100

EVLSBH92101

EVLSBH92102

EVLSA425100
EVLSA432100
EVLSA92170
EVLSA93170

EVLSA425101
EVLSA432101
EVLSA92171
EVLSA93171

EVLSA425102
EVLSA432102
EVLSA92172
EVLSA93172

EVLSBH425100

EVLSBH425101

EVLSBH425102

EVLSBH92170

EVLSBH92171

EVLSBH92172

EVLSA925170
EVLSA932170

EVLSA925171
EVLSA932171

EVLSA925172
EVLSA932172

EVLSBH925170

EVLSBH925171

EVLSBH925172

Complete
Standard Voltage Ballasts
catalog
number
CEC/CSA (cUL)
as follows: NEC/UL

Export

Multi-tap

120V

480V

Tri-Tap

120V

Suffix

/MT

/120

/480

/TT

/120

/208CWI

www.crouse-hinds.com

240V
CWI

480V
CWI

600V
CWI

220V
60 Hz

220V
50 Hz

240V
50 Hz

/240CWI

/480CWI

/600CWI

/220

/220 50

/240 50

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

4L

Voltage

208V
CWI

995

996-997.qxp

5/30/2011

4L

10:11 AM

Page 996

EVLS HazardGard
Compact & Rugged, Class I, Zone 1,
Div. 1 Explosionproof Luminaire

Cl. I, Div. 1, Group B


(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III &
Simultaneous Presence

UL and cUL Listed


Wet locations (UL1598)
Marine locations (UL1598A)
Type 4X, IP66

Ordering Information Metal Halide (Cont'd):

WALL
Wattage

70W

100W

4L

175W

Hub
Size
3
/4"
1"
11/2"
25 mm
32 mm
3
/4"
1"
11/2"
25 mm
32 mm
3
/4"
1"
11/2"
25 mm
32 mm

CEILING

No Guard
EVLSBX92070
EVLSBX93070

Wire Guard
EVLSBX92071
EVLSBX93071

Cast Guard
EVLSBX92072
EVLSBX93072

No Guard
EVLSCX92070
EVLSCX93070

Wire Guard
EVLSCX92071
EVLSCX93071

Cast Guard
EVLSCX92072
EVLSCX93072

EVLSBX925070
EVLSBX932070
EVLSBX92100
EVLSBX93100

EVLSBX925071
EVLSBX932071
EVLSBX92101
EVLSBX93101

EVLSBX925072
EVLSBX932072
EVLSBX92102
EVLSBX93102

EVLSCX925070
EVLSCX932070
EVLSCX92100
EVLSCX93100

EVLSCX925071
EVLSCX932071
EVLSCX92101
EVLSCX93101

EVLSCX925072
EVLSCX932072
EVLSCX92102
EVLSCX93102

EVLSBX425100
EVLSBX432100
EVLSBX92170
EVLSBX93170

EVLSBX425101
EVLSBX432101
EVLSBX92171
EVLSBX93171

EVLSBX425102
EVLSBX432102
EVLSBX92172
EVLSBX93172

EVLSCX925100
EVLSCX932100
EVLSCX92170
EVLSCX93170

EVLSCX925101
EVLSCX932101
EVLSCX92171
EVLSCX93171

EVLSCX925102
EVLSCX932102
EVLSCX92172
EVLSCX93172

EVLSBX925170
EVLSBX932170

EVLSBX925171
EVLSBX932171

EVLSBX925172
EVLSBX932172

EVLSCX925170
EVLSCX932170

EVLSCX925171
EVLSCX932171

EVLSCX925172
EVLSCX932172

Complete
catalog
number as
follows:

Standard Voltage Ballasts

Voltage

Multi-tap 120V

480V

Tri-Tap

120V

208V
CWI

240V
CWI

480V
CWI

600V
CWI

220V
60 Hz

220V
50 Hz

230V*
50 Hz

240V
50 Hz

Suffix

/MT

/480

/TT

/120

/208CWI

/240CWI

/480CWI

/600CWI

/220

/220 50

/230 50

/240 50

NEC/UL

/120

CEC/CSA (cUL)

Export

*Available for 175W only.

996

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

996-997.qxp

5/30/2011

10:11 AM

Page 997

Cl. I, Div. 1, Group B


(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III &
Simultaneous Presence

EVLS HazardGard
Compact & Rugged, Class I, Zone 1,
Div. 1 Explosionproof Luminaire

UL and cUL Listed


Wet locations (UL1598)
Marine locations (UL1598A)
Type 4X, IP66

4L

Ordering Information Metal Halide (Cont'd):

STANCHION

Wattage
70W
100W
175W

Complete
catalog
number as
follows:

Hub
Size
Adapter
11/2"
Adapter
11/2"
Adapter
3
/4"
11/2"

No
Guard

Wire
Guard

ADAPTER
Cast
Guard

EVLSJ95070 EVLSJ95071

EVLSJ95072

EVLSJ95100 EVLSJ95101

EVLSJ95102

EVLSJ95170 EVLSJ95171

No Guard
Wire Guard
EVLSM9070 EVLSM9071

Cast Guard
EVLSM9072

Luminaire less
mounting module
and guard
EVLS9070

EVLSM9100 EVLSM9101

EVLSM9102

EVLS9100

EVLSM9170 EVLSM9171

EVLSM9172

EVLS9100
EVLS9170

EVLSJ95172

Standard Voltage Ballasts


NEC/UL

CEC/CSA (cUL)

Voltage

Multi-tap

120V

480V

Tri-Tap

120V

208V
CWI

Suffix

/MT

/120

/480

/TT

/120

/208CWI

Export

240V
CWI

480V
CWI

600V
CWI

220V
60 Hz

220V
50 Hz

230V*
50 Hz

240V
50 Hz

/240CWI

/480CWI

/600CWI

/220

/220 50 /230 50 /240 50

*Available for 175W only.

EVLS Metal Halide:

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

4L

Fixture with Globe and Domed Reflector (less guard) EVLSA92170RD725


Lamp: 150W/ED17 Metal Halide (MH)

Copyright 2011 Cooper Crouse-Hinds

997

998-999.qxp

4L

6/13/2011

10:35 AM

Page 998

EVLS HazardGard
Compact & Rugged, Class I, Zone 1,
Div. 1 Explosionproof Luminaire

Cl. I, Div. 1, Group B


(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III &
Simultaneous Presence

EVLS Metal Halide:


Fixture with Globe and Guard EVLSA92171
Lamp: 175W/ED17 Metal Halide (MH)

EVLS Metal Halide:

4L

Fixture with Globe and Angled Reflector (less guard) EVLSA92170RA725


Lamp: 175W/ED17 Metal Halide (MH)

998

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

UL and cUL Listed


Wet locations (UL1598)
Marine locations (UL1598A)
Type 4X, IP66

998-999.qxp

6/13/2011

10:35 AM

Page 999

Cl. I, Div. 1, Group B


(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III &
Simultaneous Presence

EVLS HazardGard
Compact & Rugged, Class I, Zone 1,
Div. 1 Explosionproof Luminaire

UL and cUL Listed


Wet locations (UL1598)
Marine locations (UL1598A)
Type 4X, IP66

4L

Dimensions - Shown with new mounting modules:


10.97

3.16

15

16.47

16.36
16.97

17.85

.61
8.47

.61

BULKHEAD MOUNT

CEILING MOUNT

4.11

15.45

3.61

25

17.43
8.28

17.18

16.82

4L

.61

13.78
15.45

8.47

STANCHION MOUNT

.61

PENDANT MOUNT

9.51

16.78
17.39

8.47

.61

WALL MOUNT

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

999

1000-1001.qxp

4L

5/30/2011

10:13 AM

Page 1000

EVLS HazardGard

Cl. I, Div. 1, Group B


(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III &
Simultaneous Presence

Compact & Rugged, Class I, Zone 1,


Div. 1 Explosionproof Luminaire

UL and cUL Listed


Wet locations (UL1598)
Marine locations (UL1598A)
Type 4X, IP66

Dimensions - Shown with existing mounting modules plus EVSA Adapter:


11 15/16"

15
18 5/8"
19 3/16"
21 5/8"

CEILING MOUNT EV22, EV33


BULKHEAD MOUNT EVJ2

18 7/16"

19 1/16"
19 11/16"

20 1/16"
19 9/16"

4L

25

8 7/16"

STANCHION MOUNT EVMJ4

PENDANT MOUNT EVMP2, EVMP3

9 1/2"

3 5/16"

19"

19 5/8"

WALL MOUNT BRACKET EV87

1000

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

1012-1013.qxp

6/13/2011

4L

10:36 AM

Page 1012

EVM HazardGard
H.I.D. Luminaires
Mogul Base
Factory Sealed (Groups C, D)

Cl. I, Div. 1, Groups B (GB suffix), C, D


Cl. I, Zone 1, Groups IIB + H2
(with suffix GB), IIB IIA
Cl. II, Div. 1, Groups E, F, G; Class III

Applications:

Options:

HazardGard luminaires are used in:


Heavy process industries where
flammable or explosive vapors, gases or
combustible dusts are present
Hazardous areas, both indoors and
outdoors where long life and low
maintenance costs are desired
Petroleum refineries, chemical,
petrochemical and other heavy process
industry facilities
Paint spray facilities
Hazardous locations requiring elevated
ambient capability

NEC and CEC:


Class I, Division 1, Groups B
(with suffix GB), C, D
Class I, Zone 1, Groups IIB + H2 (with
suffix GB), IIB, IIA
100W max Paint Spray Suitability
175W max Class II, Class III
UL Standards:
844 Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations
CSA Standards:
C22.2 No. 137

Description
Suffix
Fused to protect ballast and
capacitor against abnormal line
conditions. (Not suitable for
marine applications).................... S658
Instant restrike enables a hot
HPS lamp to immediately
restrike after a momentary
loss of arc due to voltage
fluctuation or power outage. It
has no effect on the warm-up
period of a cold lamp (50-150W
LX HPS only). ..............................
IR*
Quartz auxiliary lighting quartz
lamp comes to full brightness
instantly upon restoration of
power to provide emergency
illumination during the normal
restrike period of the H.I.D. lamp
(for use with ED28 lamp).
(Quartz lamp not included; use
100 W single-ended lamp
Q100DC, Q100CL/DC, or
100Q/CL/DC.) ............................. QTZ
Ballast-Gard to eliminate
the normally continuous high
voltage pulsing in the event
of a cycling lamp, inoperative
lamp, or no lamp in the
socket extending the life of the
ballast. (For use with 50-400W
HPS lamps.) ................................
BG*
Group B suitability luminaires
suitable for use in Class I,
Group B hazardous (classified)
locations......................................
GB
HazardGard supplied with
trunnion arm for floodlighting
applications. For use on pendant
mount luminaires only. See
Floodlight Section .......................
S812

Standard Materials:

Size Ranges:

Mounting modules, cover, ballast


housing, guard, globe ring copper-free
aluminum
Globe heat and impact resistant glass
Exterior hardware stainless steel
Lamp socket porcelain with stainless
steel screw shell
Reflectors dome and angle: Krydon
fiberglass-reinforced polyester material;
high bay: Alzak aluminum

3/4", 1" and 11/4" hubs (see ordering


information see pages 10131014)

Features:

4L

Paint Spray
(100W max)
Marine & Wet
Locations
3, 3R, 4, 4X; IP66

Luminaire is factory wired; power is


fed through "wireless" connection
block which serves as a mechanical
seal between conduit and ballast
compartments, eliminating the need
for an external, field installed seal.
The result is fast, easy installation.
Dome and 30 angle reflectors made of
Krydon material won't rust, corrode,
dent, chip or peel (order separately
see page 1015).
High bay reflectors of Alzak aluminum
for high wattage applications.
Internally fluted glass globes
reduce glare and provide comfortable
viewing light.
Wide range of light sources and
wattages to meet specific lighting needs
50 400W high pressure sodium
(HPS); 70 400W metal halide (MH).
High power factor (90%+) ballasts
reduce power costs allow more
luminaires per circuit.
Four mounting arrangements to suit any
lighting layout pendant, ceiling, wall
bracket and stanchion.
Paint spray booth suitability on 50 to
100 watt luminaires provides efficient,
economical H.I.D. lighting for areas
where paint residue may accumulate
on luminaires.
Elevated ambient capability permits
reliable operation at high ambient
temperature. Selected luminaires are
suitable for ambient temperature up
to 75C.
Integral ballasts separate ballasts are
not required. Lowest installed cost.
Factory sealed, porcelain, mogul
base socket.

1012

www.crouse-hinds.com

Certifications and
Compliances:

Standard Finishes:
Copper-free aluminum epoxy
powder coat
Krydon high reflectance white
Alzak natural (anodized)

US: 1-866-764-5454

CAN: 1-800-265-0502

Electrical Rating Ranges:


120, 208, 240, 277, 347, 480,
600, multi-tap*
50 to 400 watts
*IR and BG options cannot be used together.
When ordering fuses for luminaires, option S658, you
must specify the operating voltage. S658 cannot be
ordered with /MT in the catalog number.
Can be used with BG option.
CSA Certified are not available with multi-tap ballast or
S658 fuse option.
Alzak is a registered trademark of ALCOA.

Copyright 2011 Cooper Crouse-Hinds

1012-1013.qxp

6/13/2011

10:36 AM

Page 1013

50400W EVM
HazardGard
H.I.D. Luminaires

Cl. I, Div. 1, Groups B (GB suffix), C, D


Cl. I, Zone 1, Groups IIB + H2
(with suffix GB), IIB, IIA
Cl. II, Div. 1, Groups E, F, G; Class III

Mogul Base
Factory Sealed (Groups C, D)

Pendant Luminaires
Hub
Without
Size
Guard
Watts (In.)
Cat. #
High Pressure Sodium
3
/4
EVMA42050
1
EVMA43050
50
1
1 /4

Wall Bracket Luminaires


Without
Guard
Cat. #

Ceiling Luminaires

With
Guard
Cat. #

Without
Guard
Cat. #

EVMA42051 EVMBX42050
EVMA43051 EVMBX43050

EVMBX42051
EVMBX43051

EVMCX42050 EVMCX42051
EVMCX43050 EVMCX43051

70

/4
1
11/4

EVMA42070 EVMA42071 EVMBX42070


EVMA43070 EVMA43071 EVMBX43070

EVMBX42071
EVMBX43071

EVMCX42070 EVMCX42071
EVMCX43070 EVMCX43071

100

/4
1
11/4

EVMA42100 EVMA42101 EVMBX42100


EVMA43100 EVMA43101 EVMBX43100

EVMBX42101
EVMBX43101

EVMCX42100 EVMCX42101
EVMCX43100 EVMCX43101

150

/4
1
11/4

EVMA42150 EVMA42151 EVMBX42150


EVMA43150 EVMA43151 EVMBX43150

EVMBX42151
EVMBX43151

EVMCX42150 EVMCX42151
EVMCX43150 EVMCX43151

200

/4
1
11/4

EVMA42200 EVMA42201 EVMBX42200


EVMA43200 EVMA43201 EVMBX43200

EVMBX42201
EVMBX43201

EVMCX42200 EVMCX42201
EVMCX43200 EVMCX43201

250

/4
1
11/4

EVMA42250 EVMA42251 EVMBX42250


EVMA43250 EVMA43251 EVMBX43250

EVMBX42251
EVMBX43251

EVMCX42250 EVMCX42251
EVMCX43250 EVMCX43251

400

/4
1
11/4

EVMA42400 EVMA42401 EVMBX42400


EVMA43400 EVMA43401 EVMBX43400

EVMBX42401
EVMBX43401

EVMCX42400 EVMCX42401
EVMCX43400 EVMCX43401

With
Guard
Cat. #

Paint Spray
(100W max)
Marine & Wet
Locations
3, 3R, 4, 4X; IP66

With
Guard
Cat. #

4L

Stanchion Luminaires (25)


Without
Guard
Cat. #

With
Guard
Cat. #

EVMJ44050 EVMJ44051

EVMJ44070 EVMJ44071

EVMJ44100 EVMJ44101

EVMJ44150 EVMJ44151

EVMJ44200 EVMJ44201

EVMJ44250 EVMJ44251

Complete the Catalog Number by Adding Voltage and Options Suffixes as Follows:
Standard Voltage Ballasts 60Hz
NEC/UL
1.

Voltage
Suffix

Multi Tap
/MT

CEC/CSA (cUL)
120V
/120

480V
/480

Tri Tap
/TT

Optional Voltage Ballasts 50 or 60Hz


CEC/CSA (cUL) CWI Isolated Ballasts
Voltage
Suffix

208V CWI
/208CWI

240V CWI
/240CWI

480V CWI
/480CWI

600V CWI
/600CWI

120V
/120

EXPORT
220V 60Hz
/220

2.

150W HPS Luminaires, 55V Lamps is Standard, for 100V lamps - Add suffix "CE"

3.

Options - Add the Required Options Suffixes, see page 1012, in alpha-numeric order.

www.crouse-hinds.com

220V 50Hz
/220 50

230V 50Hz
/230 50

US: 1-866-764-5454

240V 50Hz
/240 50

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

1013

4L

EVMJ44400 EVMJ44401

1014-1015.qxp

6/13/2011

4L

10:37 AM

Page 1014

Cl. I, Div. 1, Groups B


(GB suffix), C, D
Cl. I, Zone 1, Groups IIB + H2
(with suffix GB), IIB, IIA
Cl. II, Div. 1, Groups E, F, G;
Class III

70400W EVM
HazardGard
H.I.D Luminaires
Factory Sealed (Groups C, D)

Pendant Luminaires
Watts

Hub
Size (In.)

Without Guard
Cat. #

Pulse Start Metal Halide


3
EVMA92150 S828
/4
EVMA93150 S828
1
150
1
1 /4

4L

EVMCX92151 S828

EVMCX93150 S828

EVMCX93151 S828

EVMCX93170 S828

EVMCX93171 S828

/4
1
11/4

EVMA92200 S828

EVMA92201 S828

EVMBX92200 S828 EVMBX92201 S828

EVMCX92200 S828

EVMCX92201 S828

EVMA93200 S828

EVMA93201 S828

EVMBX93200 S828 EVMBX93201 S828

EVMCX93200 S828

EVMCX93201 S828

/4
1
11/4

EVMA92250 S828

EVMA92251 S828

EVMBX92250 S828 EVMBX92251 S828

EVMCX92250 S828

EVMCX92251 S828

EVMA93250 S828

EVMA93251 S828

EVMBX93250 S828 EVMBX93251 S828

EVMCX93250 S828

EVMCX93251 S828

/4
1
11/4

EVMA92320 S828

EVMA92321 S828

EVMBX92320 S828

EVMBX92321 S828 EVMCX92320 S828

EVMCX92321 S828

EVMA93320 S828

EVMA93321 S828

EVMBX93320 S828

EVMBX93321 S828 EVMCX93320 S828

EVMCX93321 S828

/4
1
11/4

EVMA92400 S828

EVMA92401 S828

EVMBX92400 S828 EVMBX92401 S828

EVMCX92400 S828

EVMCX92401 S828

EVMA93400 S828

EVMA93401 S828

EVMBX93400 S828 EVMBX93401 S828

EVMCX93400 S828

EVMCX93401 S828

EVMA92070

EVMA92071

EVMBX92070

EVMBX92071

EVMCX92070

EVMCX92071

EVMA93070

EVMA93071

EVMBX93070

EVMBX93071

EVMCX93070

EVMCX93071

/4
1
11/4

EVMA92100

EVMA92101

EVMBX92100

EVMBX92101

EVMCX92100

EVMCX92101

EVMA93100

EVMA93101

EVMBX93100

EVMBX93101

EVMCX93100

EVMCX93101

/4
1
11/4

EVMA92170

EVMA92171

EVMBX92170

EVMBX92171

EVMCX92170

EVMCX92171

EVMA93170

EVMA93171

EVMBX93170

EVMBX93171

EVMBX93170

EVMCX93171

/4
1
11/4

EVMA92250

EVMA92251

EVMBX92250

EVMBX92251

EVMCX92250

EVMCX92251

EVMA93250

EVMA93251

EVMBX93250

EVMBX93251

EVMCX93250

EVMCX93251

/4
1
11/4

EVMA92400

EVMA92401

EVMBX92400

EVMBX92401

EVMCX92400

EVMCX92401

EVMA93400

EVMA93401

EVMBX93400

EVMBX93401

EVMCX93400

EVMCX93401

Complete the Catalog Number by Adding Voltage


and Options Suffixes as Follows:
Standard Voltage Ballasts 60Hz
NEC/UL
1.

Voltage
Suffix

Multi Tap
/MT

Dual-Tap
/DT

CEC/CSA (cUL)
120V
/120

480V
/480

Tri Tap
/TT

Dual-Tap
/DT

120V
/120

Optional Voltage Ballasts 50 or 60Hz


*CEC/CSA (cUL) CWI Isolated Ballasts
Voltage
Suffix

208V CWI
/208CWI

240V CWI
/240CWI

600V CWI
/600CWI

EXPORT
220V 60Hz 220V 50Hz 230V 50Hz
/220
/220 50
/230 50

2.

150W HPS Luminaires, 55V Lamps is Standard, for 100V lamps - Add suffix "CE"

3.

Options - Add the Required Options Suffixes, see page 1012, in alpha-numeric order.

240V 50Hz
/240 50

*CWI Isolated Ballasts are only available for 175W400W metal halide (non pulse start) luminaires.

1014

Stanchion Luminaires (25)


Without Guard
Cat. #

EVMJ94150 S828

EVMBX93170 S828 EVMBX93171 S828

400

EVMCX92150 S828

EVMBX93150 S828 EVMBX93151 S828

EVMA93171 S828

250

EVMBX92150 S828 EVMBX92151 S828

EVMA93151 S828

EVMA93170 S828

175

EVMA92151 S828

EVMCX92171 S828

Metal Halide
3
/4
1
70
11/4
100

With Guard
Cat. #

EVMCX92170 S828

400

Without Guard
Cat. #

EVMBX92170 S828 EVMBX92171 S828

320

With Guard
Cat. #

EVMA92171 S828

250

Without Guard
Cat. #

EVMA92170 S828

200

With Guard
Cat. #

Ceiling Luminaires

/4
1
11/4
3

175

Wall Bracket Luminaires

Paint Spray (100W max.)


Marine & Wet Locations
3, 3R, 4, 4X; IP66

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

With Guard
Cat. #

EVMJ94151 S828

EVMJ94170 S828

EVMJ94171 S828

EVMJ94200 S828

EVMJ94201 S828

EVMJ94250 S828

EVMJ94251 S828

EVMJ94320 S828

EVMJ94321 S828

EVMJ94400 S828

EVMJ94401 S828

EVMJ94070

EVMJ94071

EVMJ94100

EVMJ94101

EVMJ94170

EVMJ94171

EVMJ94250

EVMJ94251

EVMJ94400

EVMJ94401

1014-1015.qxp

6/13/2011

10:37 AM

Page 1015

Accessories and
Temperature Performance Data

EVM HazardGard H.I.D.


Luminaires

4L

Reflectors

Dome

30 Angle

High Bay
Type

Cat. #

Dome
30 Angle
High Bay

RD739
RA739
EV3912

Temperature Performance Data


Maximum Ambient

Class I

Simultaneous
Presence

Paint
Spray
Booth

Supply
Wire

65C

75C

40C

40C

40C

T6
T5
T4A
T4
T4

T5
T4A
T4A

T4
T4
T4
T3C

T4
T4
T4
T3C

T4A
T4A
T4A

90
90
90
90
90
90
90

T3
T3

T3C
T3C
T3C
T3C

T3C
T3C
T3C
T3C

T4A
T4A

90
90
90
90
90
90
90
90

Metal Halide (Including Pulse Start)


70
T6
T6
T5
100
T5
T5
T4A
150
T4A
T4
T4
175
T4A
T4
T4
200
T4
T3C

250
T4
T3C

320
T3A

400
T3A

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

4L

Watts
40C
55C
High Pressure Sodium
50
T6
T6
70
T6
T6
100
T5
T5
150
T4A
T4A
200
T4A
T4A
250
T4
T3C
400
T3C

Class II
(E, F, G)

1015

1016-1017.qxp

5/30/2011

10:20 AM

Page 1016

EVM HazardGard H.I.D.


Luminaires

4L

Dimensions and Weights


Dimensions:

Luminaire Net Weights:


H.I.D.
Source

Lamp
Watts

50
70
100
High
150 (55V)
Pressure 150 (100V)
Sodium
200
250
400
70
100
175
250
400

Metal
Halide

Luminaire Only
with Globe and
Guard (lbs.)
40
40
44
45
44
46
46
55
39
39
42
43
51

Type
Lbs.
Type
Add for Mounting Modules:
Pendant
Bracket
1
Ceiling
Stanchion
2

Lbs.
41/4
21/4

4L

Add for Reflectors:


RD739
13/4
RA739
2
EV3912
21/2
Deduct: 11/2 lbs. for luminaire without guard.

Guard
EV503
EV5140

All Reflectors

100, 175, 250W MV 50, 70, 100, All luminaires with QTZ option
150W HPS 70, 100, 175, 250W
and 200, 250, 400W HPS
MH
400W MV & MH

Type
EVMA
EVMBX
EVMCX
EVMJ

1016

a
25 /16
277/8
24
2211/16
1

www.crouse-hinds.com

26
2813/16
2415/16
241/8

27 /16
301/8
261/4
251/4

US: 1-866-764-5454

g
5

CAN: 1-800-265-0502

28 /4
311/16
273/16
261/8
1

Dome

High
Bay

30
Angle

23 /8
2611/16
2213/16
253/8
7

Copyright 2011 Cooper Crouse-Hinds

26 /16
293/4
253/8
2711/16
7

289/16
313/8
271/2
283/4

1016-1017.qxp

5/30/2011

10:20 AM

Page 1017

EVM HazardGard H.I.D.


Luminaires

Photometric Data

Lamp: 150W/E-23-1/2 high pressure sodium (HPS)


Total bare lamp lumens: 16,000

Coefficient of Utilization

Luminaire With Globe and Without Guard


Note: Photometric data was
developed using a 150 watt
clear high pressure sodium
lamp (16,000 lumens). For
other clear lamps, use the
following conversion factors
(multipliers): 50W HPS .25;
70W HPS .40; 100W HPS
.59. Multipliers are for use
with candela curve only.
Luminaire spacing ratio is
0.80.

Effective Floor Cavity Reflectance 20%


% Reflectance
Eff. Ceil.
Wall

Room Cavity Ratio


1
2
3

80

50
30
10

.695
.644
.599

.579
.509
.450

.494
.417
.356

.410
.326
.262

.382
.305
.246

70

50
30
10

.659
.613
.570

.549
.484
.431

.469
.397
.341

.387
.311
.251

.363
.291
.236

50

50
30
10

.592
.555
.522

.491
.439
.393

.419
.360
.312

.344
.279
.229

.327
.265
.218

30

50
30
10

.531
.502
.474

.438
.396
.358

.373
.325
.284

.304
.250
.207

.292
.240
.200

10

50
30
10

.476
.451
.429

.390
.355
.325

.331
.291
.257

.267
.222
.184

.260
.217
.181

.399

.295

.230

.159

10

80

50
30
10

.342
.266
.212

.306
.234
.184

.278
.209
.160

.265
.198
.153

.233
.168
.127

70

50
30
10

.324
.254
.202

.292
.223
.176

.265
.201
.155

.253
.191
.149

.222
.163
.123

50

50
30
10

.292
.232
.187

.263
.203
.162

.240
.184
.143

.231
.177
.139

.203
.150
.114

30

50
30
10

.262
.211
.172

.236
.186
.148

.218
.167
.132

.210
.162
.129

.185
.138
.105

10

50
30
10

.234
.190
.156

.213
.169
.135

.195
.152
.121

.191
.149
.118

.167
.125
.096

.135

.116

.103

.103

.081

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

1017

4L

.159

Room Cavity Ratio


6
7
8

% Reflectance
Eff. Ceil.
Wall

www.crouse-hinds.com

4L

1018-1019.qxp

6/13/2011

10:38 AM

Page 1018

EVM HazardGard H.I.D.


Luminaires

4L

Photometric Data

Lamp: 150W/E-23-1/2 high pressure sodium (HPS)


Total bare lamp lumens: 16000

Lamp: 150W/E-23-1/2 high pressure sodium (HPS)


Total bare lamp lumens: 16000

Luminaire With Globe, Hi-Bay Reflector


and Without Guard

Luminaire With Globe, Dome Reflector and


Without Guard

Note: Photometric data was


developed using a 150 watt clear
high pressure sodium lamp
(16,000 lumens). For other clear
lamps, use the following
conversion factors (multipliers):
50W HPS .25; 70W HPS .40;
100W HPS .59. Multipliers are
for use with candela curve only.

Note: Photometric data was


developed using a 150 watt
clear high pressure sodium
lamp (16,000 lumens). For
other clear lamps, use the
following conversion factors
(multipliers): 50W HPS .25;
70W HPS .40; 100W HPS
.59. Multipliers are for use with
candela curve only.

Luminaire spacing ratio is 1.00.

Luminaire spacing ratio is 1.20.

Coefficient of Utilization

Coefficient of Utilization

Effective Floor Cavity Reflectance 20%

Effective Floor Cavity Reflectance 20%

4L

% Reflectance
Eff. Ceil. Wall

Room Cavity Ratio


1
2
3

% Reflectance
Eff. Ceil. Wall

Room Cavity Ratio


1
2
3

80

50
30
10

.668
.651
.636

.618
.592
.569

.573
.542
.517

.531
.495
.468

.494
.455
.427

80

50
30
10

.716
.689
.666

.637
.596
.561

.568
.519
.480

.507
.452
.410

.455
.398
.355

70

50
30
10

.655
.639
.625

.608
.583
.564

.566
.536
.513

.525
.491
.464

.487
.452
.425

70

50
30
10

.700
.675
.653

.624
.585
.555

.559
.512
.476

.498
.447
.407

.446
.393
.353

50

50
30
10

.629
.616
.606

.587
.568
.550

.550
.525
.505

.511
.482
.459

.476
.446
.422

50

50
30
10

.668
.648
.631

.598
.567
.539

.538
.498
.466

.479
.435
.400

.432
.385
.349

30

50
30
10

.606
.597
.588

.569
.554
.539

.535
.514
.497

.498
.474
.454

.466
.438
.418

30

50
30
10

.640
.625
.610

.575
.549
.526

.518
.485
.457

.463
.425
.394

.417
.376
.344

10

50
30
10

.586
.578
.570

.553
.539
.528

.522
.504
.489

.487
.466
.449

.457
.433
.413

10

50
30
10

.615
.602
.590

.554
.532
.513

.500
.472
.448

.447
.415
.388

.404
.369
.339

.560

.517

.479

.439

.404

.575

.498

.434

.373

.326

% Reflectance
Eff. Ceil. Wall

% Reflectance
Eff. Ceil. Wall

Room Cavity Ratio


6
7
8

10

80

50
30
10

.460
.420
.394

.427
.388
.361

.396
.358
.330

.369
.330
.303

.328
.288
.262

70

50
30
10

.455
.418
.391

.423
.385
.359

.392
.356
.329

.366
.328
.303

50

50
30
10

.444
.412
.388

.414
.380
.357

.385
.352
.328

30

50
30
10

.436
.407
.385

.406
.377
.354

10

50
30
10

.428
.402
.382

.373

1018

Room Cavity Ratio


6
7
8

10

80

50
30
10

.413
.355
.316

.373
.318
.280

.339
.285
.246

.312
.258
.221

.275
.222
.187

.325
.288
.262

70

50
30
10

.405
.352
.312

.368
.314
.277

.334
.283
.245

.308
.256
.221

.271
.222
.187

.360
.325
.301

.320
.285
.261

50

50
30
10

.392
.345
.309

.356
.307
.274

.324
.277
.243

.299
.252
.219

.264
.217
.185

.379
.348
.326

.354
.322
.300

.315
.282
.259

30

50
30
10

.380
.338
.306

.345
.303
.270

.316
.272
.241

.291
.247
.217

.257
.214
.183

.400
.373
.352

.373
.345
.324

.348
.319
.298

.311
.280
.258

10

50
30
10

.369
.331
.301

.337
.298
.267

.307
.267
.238

.283
.244
.215

.251
.210
.181

.343

.315

.290

.249

.289

.255

.226

.203

.170

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

Cl. I, Div. 2, Groups A, B, C, D


Maintains Cl. I, Div. 2 Suitability of Cooper
Crouse-Hinds Champ Series Luminaires

Photocells

3L

V2PC, D2S and EV2IH Series


The only UL recognized photocells for Class I, Division 2 areas.
Eliminates the need for an explosionproof box!
Cooper Crouse-Hinds factory-sealed, field installed photocells offer
reliable, dusk-to-dawn lighting control in Class I, Division 2 locations.
These photocells are ideal for walkways, security lighting, and any
other outdoor lighting application that utilizes Champ H.I.D. lighting
luminaires.

Applications:
Cooper Crouse-Hinds photocells are designed:
To provide control for automatic dusk-to-dawn lighting.
For safety by turning on outdoor luminaires in critical passageways
at night.
To save energy by operating luminaires only when necessary.
For walkways, parking areas, outdoor process areas, security
lighting, or any outdoor lighting application in Class I, Division 2
locations and corrosive environments.
For use with LMV, DMV, VMV, VMV High Wattage, and FMV Series
Champ lighting luminaires (V2PC Series).
For use on 35400 watt H.I.D., incandescent, or fluorescent
lighting luminaires.

Certifications and Compliances:


V2PC Series and D2S Series
NEC/CEC:
Class I, Division 2, Groups A, B, C, D

For remote mounting in FS boxes (D2S Series).

UL Standard: 844 Hazardous (Classified) Locations

For mounting in EIH enclosures for Class I, Division 1 applications


(EV2IH Series).

CSA: C22.2 No. 55

Features:

EV2IH Series
NEC/CEC:
Class I, Division 1 and 2, Groups B, C, D

Field-installable.

Class II, Division 1, Groups E, F, G

Solid-state design for performance and dependability.

Class II, Division 2, Groups F, G

Factory sealed components.


Explosionproof enclosure not required for Class I, Division 2
locations.

UL Standard: 844 Hazardous (Classified) Locations

3L

Luminaires turn on at 3 footcandles, off at 8 footcandles insuring


that the luminaires are operating only when needed.

Class III
NEMA: 3, 4, 7BCD, 9EFG

CSA: C22.2 No. 30, 55

Built-in 10 second time delay to eliminate nuisance tripping.


Eight-year operating life.

Electrical Rating Ranges:

Furnished with 6" stranded 600 volt color coded wire leads.

120, 208, 220, 240, 277 VAC

Constructed from corrosion-resistant thermoplastic polyester.

50 / 60 Hz

Available on a DS cover for use with any FS/FD box (D2S Series).

35400 watt H.I.D., incandescent, or fluorescent

Available in an EIH enclosure for use in Class I, Division 1, Groups


B*, C, and D locations (EV2IH Series). No seals required.

V2PC20 3.3A max. current rating


V2PC22 1.8A max. current rating

*For Group B applications, seal within 11/2" of enclosure in accordance with Section 501-5 of
the National Electric Code.

www.crouse-hinds.com

V2PC27 1.4A max. current rating

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2012 Cooper Crouse-Hinds

979

980-981.qxp

5/30/2011

3L

10:01 AM

Page 980

Photocells

Cl. I, Div. 2, Groups A, B, C, D


Maintains Cl. I, Div. 2 Suitability of Cooper
Crouse-Hinds Champ Series Luminaires

V2PC, D2S and EV2IH Series


Ordering Information:
Photocell for field installation in lighting fixtures*
Cat. #

Voltage Range

Current Rating

V2PC20
V2PC22
V2PC27

120V, 50/60Hz
208240V, 50/60Hz
277V, 50/60Hz

3.3A
1.8A
1.4A

Photocell in DS cover for use with FS/FD box


Cat. #

Voltage Range

D2S20
D2S208 277

120V, 50/60Hz
208V-277V

Photocell in EIH enclosure for use in Class I, Division 1, Groups B, C, and D;


Class II, Division 1, Groups E, F, and G; and Class III locations
Cat. #

Voltage Range

EV2IH20
EV2IH208 277

120V, 50/60Hz
208-277V 50/60Hz

3L

Replacement Photocell for D2S Cover or EIH


Enclosure *
Cat. #

Voltage Range

Current Rating

V2PCT20
V2PCT208 277

120V, 50/60Hz
208V-277V 50/60Hz

8.33A
4.81A - 3.61A depending on voltage

* Must be factory installed in Canada.


When mounting in EIH enclosures for Class I, Division 1 applications (EV21H Series) seals are not required for Groups C & D.

Options:
To order luminaire with photocell factory installed:
1. Specify luminaire dedicated supply voltage (not MT, DT, or TT)
2. Add photocell Cat. No. to fixture Cat. No. as follows:
V2PC20
V2PC22
V2PC27
Example: VMVSJ070GP/120-V2PC20 is a 120V 60Hz luminaire with
a factory installed photocell.
Note: Only the V2PC is available as a factory installed photocell.

980

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

980-981.qxp

5/30/2011

10:01 AM

Page 981

Photocells

Cl. I, Div. 2, Groups A, B, C, D


Maintains Cl. I, Div. 2 Suitability of Cooper
Crouse-Hinds Champ Series Luminaires

3L

V2PC, D2S and EV2IH Series


Dimensions:
In Inches:
V2PC

EV2IH

V2PCT

D2S

Cat. #

EV2IH

5.00

4.25

2.60

4.54

5.25

3L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

981

976-977.qxp

5/30/2011

9:59 AM

Page 977

Accessories

Champ H.I.D. Luminaires

3L

VMV, LMV, DMV, VMV High Wattage


& N2MV Series
Globes

Reflectors

Dome Krydon material


G54

G24

30 Angle
Krydon material

G303

Lamp
Watts

Luminaire Series

Type

35150
50175
50250
200400
250
50175

LMVS, LMVM
VMVM, VMVS
DMVM, DMVS
VMVS
VMVM
N2MVM, N2MVS

Heat/impact
Heat/impact
Heat/impact
Heat/impact
Heat/impact
Heat/impact

Cat. #
resistant
resistant
resistant
resistant
resistant
resistant

G54
G24
G303
G303
G303
G303

Lamp Watts

Luminaire Series

Dome Cat. #

Angle Cat. #

35150
50175
50250
200400
250
50175

LMVS, LMVM
VMVM, VMVS
DMVM, DMVS
VMVS
VMVM
N2MV, N2MVF(B)

RD636
RD70
RD739
RD739
RD739
RD739

RA636
RA70
RA739
RA739
RA739
RA740

Reflector / Lens
Guards

Etched Alzak aluminum reflector/tempered glass lens

P50 use with


G54 globe

P21 use with


G24 globe

P33 use with


G303 globe

Lamp Watts

Luminaire Series

Type

Cat. #

200400
70250

VMVM, VMVS
DMVS, DMVM

Reflector/Lens
Reflector/Lens

GRD4
GRD4

3L

Globes Teflon Coated


Teflon coated for increased shatter protection
Lamp Watts

Luminaire Series

Cat. #

50175
50175

VMVM, VMVS
DMVM, DMVS

G24 S808
G303 S808

Alzak is a registered trademark of Alcoa.


Teflon is a registered trademark of E.I. DuPont Co.

P23 use with refractors


Lamp
Watts

Luminaire Series

Type

Cat. #

35150
50175
50250
200400
250
Refractors
50175

LMVS, LMVM
VMVM, VMVS
DMVM, DMVS
VMVS
VMVM
All
N2MVM, N2MVS

Copper-free aluminum
Copper-free aluminum
Stainless steel
Stainless steel
Stainless steel
Stainless steel
Stainless steel

P50
P21
P33
P33
P33
P23
P33

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

977

978-979.qxp

5/30/2011

10:00 AM

Page 978

Champ H.I.D. Luminaires

3L

Accessories

VMV, LMV, DMV, VMV High Wattage


& N2MV Series
Refractors

Safety Lighting Options


Description
Suffix
Quartz Auxiliary Lamp
QTZ
The quartz auxiliary lamp comes to full brightness instantly and
remains lit until the H.I.D. lamp attains 6070% of full illumination.
Quartz auxiliary lamps can be used with all DMV, VMV and VMV
High Wattage series Champ luminaires. Use for non-hazardous
applications ONLY.
VMV luminaires (50175W) ordered with this option must use large
glass refractor optics, not compact refractors.

R2, R5, PR2, PR3, PR5

GR302, GR303, GR305

Lamp
Watts

Luminaire
Series

I.E.S.
Type

Glass
Cat. #

Plastic (100W max.


non-hazardous)
Cat. #

50175

VMVM,
VMVS

II
III
V

R2
R3
R5

PR2
PR3
PR5

200400

VMVM,
VMVS

II
III
V

GR302
GR305
GR305

50250

DMVS,
DMVM

II
III
V

GR302
GR303
GR305

50175

N2MV

100W single ended lamp Q100CL/DC, Q100DC or 100Q/CL/DC


NOT furnished
Instant Restrike
IR
Factory installed instant restrike device will restart a hot High
Pressure Sodium lamp after a momentary power interruption,
without the typical delay for cooling.
For use in 50150W "LX" HPS luminaires.
Ballast-Gard
BG
Ballast-Gard starter cut-out switch prevents starter pulsing after a
time delay of approximately two minutes if the lamp fails to start.

PGR302
PGR303
PGR305

For use in 50400 watt HPS luminaires only.

3L

I.E.S. Distribution Curves

Type I

Type II

Type III

Type V

Luminaire
Series

I.E.S.
Type

Glass
Cat. #

VMVM,
VMVS

I
III
V

G241
G243
G245
P241

Compact Refractors

Lamp
Watts
50175

Optional stainless steel wire guard

978

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

934-935.qxp

6/13/2011

3L

10:14 AM

Page 934

LMV Series 50-150W


Low Profile Medium Base
Champ H.I.D. Luminaires

Cl. II, Groups E, F, G; Cl. III


& Simultaneous Presence
(HPS 35W, 50W)
Marine & Wet Locations
3, 3R, 4, 4X; IP66

Applications:

Options:

LMV series Champ luminaires are used:


In applications involving low luminaire
mounting heights or restricted mounting
space or where luminaire weight is a
factor
In areas in which ignitible concentrations
of flammable gases or vapors will be
present only due to abnormal, unusual,
or accidental conditions
Where combustible dusts are present
Where combustible dusts and flammable
vapors are present simultaneously
In elevated ambient temperatures often
found in industrial applications
In marine applications where water
spray and corrosive atmospheres are
considerations
Wherever the damaging effects of wind,
snow, sleet, or hot sun are found
In manufacturing plants, chemical,
petrochemical, and other industrial
process facilities, waste or sewage
treatment facilities, offshore or dockside
installations, cold storage facilities,
parking garages or wherever dust, dirt,
water, vibration and rough usage are a
problem

The following special options are available


from the factory by adding suffix to
luminaire Cat. No.:
Description
Suffix
Restricted Breathing
Construction .............................
S826
Class I, Division 2 & Zone 2
Suitability
Cooler Operating
Temperatures (T-Numbers)
Certified for IEC Zone 2............. S826TB
Furnished with terminal block,
crimp terminals and dedicated
voltage ballasts (no MT, DT,
or TT)
Fused to protect ballast and
capacitors against abnormal
line conditions .......................... S658*
(Not for use in Canada)
(Not suitable for marine
applications)
Quick-Clip - Holds weight of
housing when closed. No need
to support luminaire while
screwing the housing to the
cover ........................................
S890
Ballast-Gard starter cut-out
switch prevents starter
pulsing when lamp is cycling
or inoperative; prolongs ballast
and ignitor life. Available for use
with 50100W HPS only ............
BG
Factory assembled with H.I.D.
lamps installed for additional
labor savings .............................
FA
Stainless steel insert top
hat with stainless steel
threaded insert to attach
ballast housing ..........................
S806

Features:

3L

Cl. I, Div. 2, Groups A, B, C, D


Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

Compact, lightweight design is ideal for


low mounting heights.
Cast copper-free aluminum construction
(less than 0.4 of 1% copper) and epoxy
powder finish provide excellent
resistance to corrosion.
Seven mounting arrangements to suit
any lighting layout pendant, flexible
pendant, ceiling, wall, straight stanchion,
angle stanchion, and quad-mount.
Wide range of lamp wattages to meet
specifiers' needs: 50, 70, 100 and 150
watt (HPS); 70 and 100 watt (MH)
medium base lamps.
Hinged ballast housing for ease of
installation and maintenance.
All luminaires designed to perform in a
40C ambient temperature. Selected
luminaires are suitable for ambient
temperatures up to 65C.
Superior gasketing seals between the
mounting module, housing, and optical
assembly for optimum performance in
wet and corrosive environments.
Hubs with an integral conduit stop and
bushing to help prevent damage to field
wiring during installation.
Low ambient capability to 40C.
Dome and 30 angle reflectors made of
bright white Krydon material provide
superior reflectivity, with twist-on feature
requiring no tools or additional
hardware. Will not chip, peel, dent, rust,
or corrode.
Grounding wire for safety.
Medium base lamp sockets.
934

www.crouse-hinds.com

Certifications and
Compliances:
NEC/CEC:
Class I, Division 2, Groups A, B, C, D
HPS 35W, 50W Class II, Class III &
Simultaneous Presence (Class I,
Division 2 and Class II)
Class I, Zone 2
IEC:
Zone 2 Ex nR IIC
UL Standards:
844 Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations
CSA Standards:
C22.2 No. 137
IEC Standards:
60079-15

Standard Materials:
Ballast housings and mountings
copper-free aluminum (less than
0.4 of 1%)
Exterior hardware stainless steel
Reflectors (dome and angle) Krydon
fiberglass-reinforced polyester material
Globes heat and impact resistant,
internally fluted glass
Guards copper-free aluminum

Accessories:
See pages 977978 for complete listing

Standard Finishes:
Copper-free aluminum epoxy powder
coat
Krydon material high reflectance white
Stainless steel natural

Electrical Ratings:
120 volts, dual-tap (120/277), multi-tap*
50, 70, 100, 150 watts HPS**
70 and 100 watts MH

* When ordering fuses for luminaires, option S658, you


must specify the operating voltage. S658 cannot be
ordered with /MT in the catalog number.
** 150W HPS is not avalable with multi tap ballast.
120V only.

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

934-935.qxp

6/13/2011

10:14 AM

Page 935

Cl. I, Div. 2, Groups A, B, C, D


Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

LMV Series 50150W


High Pressure Sodium
Low Profile - Medium Base
Champ H.I.D. Luminaires

Cl. II, Groups E, F, G; Cl. III


& Simultaneous Presence
(35W, 50W)
Marine & Wet Locations
3, 3R, 4, 4X; IP66

3L

To complete the catalog #, include information in notes 1, 2 and 3 below. For guards and other optics see LMV Series - Ordering By Components page.
BASIC CATALOG NUMBER
Mounting
Style

Hub
Size

Lamp
Watts

With G54 Globe


and P50 Guard

Pendant Mount

/4
1
3
/4
1
3
/4
1
3
/4
1

50

LMVS2A050GP
LMVS3A050GP
LMVS2A070GP
LMVS3A070GP
LMVS2A100GP
LMVS3A100GP
LMVS2A150GP
LMVS3A150GP

/4
/4
3
/4
3
/4

50
70
100
150

LMVS2HA050GP
LMVS2HA070GP
LMVS2HA100GP
LMVS2HA150GP

/4
1
/4
1
3
/4
1
3
/4
1

50

70

LMVS2C050GP
LMVS3C050GP
LMVS2C070GP
LMVS3C070GP
LMVS2C100GP
LMVS3C100GP
LMVS2C150GP
LMVS3C150GP

/4
1
3
/4
1
3
/4
1
3
/4
1

50

Flexible Pendant Mount

3
3

Ceiling Mount Thru-Feed

Wall Mount Thru-Feed

70
100
150

100
150

LMVS2TW050GP
LMVS3TW050GP
LMVS2TW070GP
LMVS3TW070GP
LMVS2TW100GP
LMVS3TW100GP
LMVS2TW150GP
LMVS3TW150GP

70
100
150

/4
/4
3
/4
3
/4

50
70
100
150

LMVS25Q050GP
LMVS25Q070GP
LMVS25Q100GP
LMVS25Q150GP

Stanchion Mount
25 Angle

11/2
11/2
11/2
11/2

50
70
100
150

LMVSJ050GP
LMVSJ070GP
LMVSJ100GP
LMVSJ150GP

Stanchion Mount
Straight

11/2
11/2
11/2
11/2

50
70
100
150

LMVSP050GP
LMVSP070GP
LMVSP100GP
LMVSP150GP

3L

Quad Mount
Pendant, Adjustable
Thru-Feed, 25 Angle,
121/ 2 Angle

1. Add voltage suffix to end of catalog number


Standard Voltage Ballasts 60Hz
NEC/UL
Voltage
Suffix

Multi Tap
/MT

Dual Tap
/DT

CEC/CSA (cUL)
120V
/120

480V
/480

Tri Tap
/TT

Dual Tap
/DT

120V
/120

2. 150W HPS Luminaires: For 55V lamps - add suffix LX. 50W HPS luminaire is dual tap only. 150W HPS is not avalable with multi tap ballast. 120V only.
3. Options - Add the required option suffixes, see page 934, in alpha-numeric order.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

935

936-937.qxp

6/13/2011

3L

10:14 AM

Page 936

LMV Series 70-100W


Metal Halide

Cl. I, Div. 2, Groups A, B, C, D


Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

Low Profile - Medium Base


Champ H.I.D. Luminaires

Marine & Wet Locations


3, 3R, 4, 4X; IP66

To complete the catalog #, include information in notes 1, 2 and 3 below. For guards and other optics see LMV Series - Ordering By Components page.
BASIC CATALOG NUMBER
Mounting Style
Pendant Mount

Hub
Size

Lamp
Watts

With G54 Globe


and P50 Guard

3
/4
1
3
/4
1

70

LMVM2A070GP
LMVM3A070GP
LMVM2A100GP
LMVM3A100GP

100

/4
/4

70
100

LMVM2HA070GP
LMVM2HA100GP

3
/4
1
3
/4
1

70

LMVM2C070GP
LMVM3C070GP
LMVM2C100GP
LMVM3C100GP

3
/4
1
3
/4
1

70

Stanchion Mount
25 Angle

11/2
11/2

70
100

LMVMJ070GP
LMVMJ100GP

Stanchion Mount
Straight

11/2
11/2

70
100

LMVMP070GP
LMVMP100GP

Flexible Pendant Mount

Ceiling Mount
Thru-Feed

LMVM2TW070GP
LMVM3TW070GP
LMVM2TW100GP
LMVM3TW100GP

100

3L

Wall Mount Thru-Feed

100

1. Add voltage suffix to end of catalog number


Standard Voltage Ballasts 60Hz
NEC/UL
Voltage
Suffix

Multi Tap
/MT

CEC/CSA (cUL)
120V
/120

480V
/480

Tri Tap
/TT

120V
/120

2. 70W ballast not available in 480V.


3. Options - Add the required option suffixes, see page 934, in alpha-numeric order.

936

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

936-937.qxp

6/13/2011

10:14 AM

Page 937

LMV Series Ordering by Components

3L

LMV luminaires are available in components.


A complete luminaire consists of:
I.
II.
III.

Champ Cover (Mounting Module)


LMV Ballast Housing Include voltage and required option(s)
Globe, Guard, Reflector

I. Champ Cover (Mounting Module):


Type
Pendant

Conduit

Cat. #

/4"
1"

APM2
APM3

Flexible Pendant

/4"

HPM2

Ceiling

/4"
1"

CM2
CM3

Wall

3
/4"
1"

TWM2
TWM3

Stanchion 25 Degree Angle

11/2"

JM5

Stanchion Straight

1 /2"

PM5

Quad-Mount

/4"

QM25

II. Ballast Housings:


Complete catalog number must have the voltage suffix (MT shown) and any options suffixes.
Lamp Type
Lamp Watts
Cat. #
High Pressure Sodium

50
70
100
150

LMVS050/120
LMVS070/MT
LMVS100/MT
LMVS150/120 LX

Metal Halide

70
100

LMVM070/MT
LMVM100/MT

Type

Cat. #

Globe
Globe Guard
Reflector Dome
Reflector Angle

G54
P50
RD636
RA636

www.crouse-hinds.com

US: 1-866-764-5454

3L

III. Globe, Guards and Reflectors:

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

937

938-939.qxp

3L

5/30/2011

9:41 AM

Page 938

LMV Series

Family Tree

3L

Champ H.I.D. Luminaires

938

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

938-939.qxp

5/30/2011

9:41 AM

Page 939

LMV Series

Temperature Performance Data

3L

Champ H.I.D. Luminaires


Rated
Ambient
C

Lamp

Cat. #

Wattage

Type

LMVS50
LMVS50
LMVS50
LMVS70
LMVS70
LMVS100
LMVS100

50
50
50
70
70
100
100

HPS
HPS
HPS
HPS
HPS
HPS
HPS

LMVM70
LMVM70
LMVM100

70
70
100

LMVM150

150

40
55
65
40
55
40

Class I,
Division 2
Globe (G54)
w/ or w/o
Reflector
(RA636 or
RD636)

Class II, Division 1


Globe (G54)
w/ or w/o
Reflector
(RA636 or
Group
RD636)

Simultaneous
Presence
Class I, Div. 2
Class II, Div. 1

Class I, Zone 2
Restricted
Factory
Breathing
Sealed
Suffix
Suffix
S826 w/
S865
Globe (G24) AEx nA nR II

Supply
Wire
Suitable
for C

50

T2D
T2C
T2C
T2B
T2B
T2

EFG

T3C

T2B

T5
T4
T4
T4
T4
T4
T3

T3
T3
T3
T3
T3
T3
T3

N/A
75
85
75
85
85
90

MH
MH
MH

40
55
40

T2B
T2B

T4
T4
T3

T3
T3
T3

75
85
85

HPS

40

T1 350C

85

The Class I, Division 2 T-codes apply to luminaires without the restricted breathing (S826) or factory sealed (S865) options. These luminaires
are listed to UL 844. UL 844 specifies how the temperatures are measured.
The Class I, Zone 2 T-codes are for luminaires that are additionally listed to UL 60079-15 that specify a different method for measuring
temperatures. Since NEC 501.1 states that equipment "...for use in Class I, Zone 0, 1, or 2 locations shall be permitted in Class I, Division 2
locations..." then these luminaires are suitable for Class I, Division 2 but with lower temperature ratings. They also have the advantage of
meeting the more rigorous mechanical tests of UL 844.

3L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

939

940-941.qxp

5/30/2011

9:42 AM

Page 940

LMV Series

3L

Dimensions and Weights

Champ H.I.D. Luminaires


Dimensions

Luminaire Net Weights:

In Inches:
Luminaire
Series
LMVS

LMVM
Pendant Mount

Wall Mount

Top View

Ceiling Mount

Lamp
Watts

Luminaire
with Globe,
Guard (lbs.)

50
70
100
150

73/4
81/4
83/4
91/4

70
100

9
9

Type
Add for mounting modules:
Pendant
Flexible Pendant
Ceiling
Quad-Mount
Wall
Angle Stanchion
Straight Stanchion

Lbs.

Type
Add for reflectors:
Dome
30 Angle

lbs.

Deduct for luminaire without guard:


P50 Guard

Luminaire with Globe, Guard,


Reflectors

Straight Stanchion Mount

25 Angle Stanchion Mount

3L

Quad-Mount

940

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

11/4
11/2
23/4
31/2
41/2
31/2
41/2

1.0
1.0
/2

940-941.qxp

5/30/2011

9:42 AM

Page 941

Photometric Data

LMV Series

3L

Champ H.I.D. Luminaires


Lamp: 100W/E-17 high pressure sodium (HPS)
Total bare lamp lumens: 9500
All data provided is for high pressure sodium luminaires with 100W/E-17 clear lamps. Use conversion factors (multipliers) shown below for other lamp types and wattages. Consult Cooper
Crouse-Hinds for additional photometric data on any Champ Series.

Luminaire with Globe and Dome Reflector


Multipliers (for use with candela
curve only).
ConLuminaire Lamp
version
Series
Watts Factor
35
50
70
150

LMVS

Isofootcandle Chart: Luminaire with Globe


and Dome Reflector

0.24
0.42
0.67
1.68

Luminaire spacing ratio: 2.0

Coefficient of Utilization
Effective Floor Cavity Reflectance 20%
% Reflectance
Eff. Ceil.

Room Cavity Ratio


1

80

50
30
10

.722
.691
.663

.628
.579
.537

.545
.487
.441

.473
.408
.358

.413
.346
.296

70

50
30
10

.705
.676
.650

.613
.568
.531

.534
.479
.436

.463
.403
.355

.403
.340
.293

50

50
30
10

.671
.647
.627

.585
.548
.514

.511
.464
.426

.442
.390
.349

.387
.332
.289

30

50
30
10

.641
.623
.605

.560
.529
.501

.489
.450
.416

.424
.379
.342

.371
.322
.284

10

50
30
10

.614
.598
.584

.537
.510
.488

.470
.436
.407

.407
.367
.335

.356
.341
.279

.568

.471

.391

.319

.263

Wall

10

80

50
30
10

.366
.300
.253

.324
.259
.215

.288
.225
.180

.261
.199
.156

.226
.165
.127

70

50
30
10

.358
.295
.249

.318
.255
.212

.282
.223
.179

.256
.196
.156

.221
.165
.126

50

50
30
10

.343
.288
.246

.305
.248
.209

.271
.217
.177

.246
.192
.154

.214
.161
.124

30

50
30
10

.330
.280
.242

.292
.243
.205

.261
.210
.175

.237
.186
.152

.206
.157
.122

10

50
30
10

.317
.272
.238

.282
.237
.202

.251
.206
.172

.228
.182
.149

.199
.152
.120

.223

.187

.158

.136

.107

% Reflectance
Eff. Ceil

Isofootcandle Chart: Luminaire with Globe


and 30 Angle Reflector

3L

Wall

Room Cavity Ratio

www.crouse-hinds.com

Isofootcandle charts show illumination in footcandles on work plane


10 feet below light center. Multiply by factor shown to convert to
other mounting heights.

US: 1-866-764-5454

Height (Ft.)

Factor

Height (Ft.)

Factor

6
8
12

2.78
1.56
0.70

14
16

0.51
0.39

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

941

960-961.qxp

6/13/2011

3L

10:19 AM

Page 960

N2MV Series 50-175W


Non-metallic

3L

Champ H.I.D. Luminaires

Cl. I, Div. 2, Groups A, B, C, D


Cl. II, Groups F, G
Cl. III & Simultaneous
Presence (100W max)

Marine & Wet Locations


3, 3R, 4, 4X; IP56

Applications:

Options:

N2MV series Champ luminaires are used:


In areas in which ignitable
concentrations of flammable gases or
vapors will be present due to abnormal,
unusual or accidental conditions.
In installations where moisture, dirt,
vibration, corrosion or rough usage are
concerns.
Wherever the damaging effects of water,
wind, snow, sleet, hot sun or any
combination of these elements are
found.
Ideal for marine use; resists the harmful
effects of salt water.
Withstands the harshest of corrosive
environments.
To provide low wattage spot and
floodlighting.
For general area lighting.
In areas where the ambient temperature
will get as low as 40C (40F).
In manufacturing plants, refineries,
chemical, petrochemical and other
industrial process facilities, wastewater
and sewage treatment facilities,
offshore, dockside and harbor
installations as well as other heavy
industrial applications.

The following special options are available


from the factory by adding suffix to
luminaire Cat. No.:

Certifications and
Compliances:

Features:

Standard Materials:

Housing and mounting modules made of


polyphenylene sulfide (PPS) for strength
and maximum resistance to corrosion.
Pendant mounting module equipped
with integral hub set screws for vibration
resistance.
Hubs are provided with an integral
bushing to help prevent damage to field
wiring during installation and ground
connection for positive bonding.
Guard, hub inserts, stanchion elbow and
hardware made of stainless steel for
maximum resistance to corrosion.
Grounding wire for safety.
Stainless steel open bottom guard
permits direct access to the globe for
easy relamping.
Hinged assembly allows the luminaire to
hang free during installation to permit the
use of both hands when wiring.
One external captive screw for ease of
installation.
Handle hinge assembly doubles as a
handle for ease of installation, especially
when carrying up a ladder.

Housing, mounting modules,


component pallets polyphenylene
sulfide (PPS)
Guard, hub inserts, stanchion elbow,
hardware stainless steel
Globe heat tempered
Gaskets silicone rubber

960

www.crouse-hinds.com

NEC and CEC:


Class I, Division 2, Groups A, B, C, D
100W Maximum Class II, Class III &
Simultaneous Presence (Class I,
Division 2 and Class II)
UL Standards:
844 Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations
CSA Standards
C22.2 No. 137

Electrical Ratings:
120, multi-tap/MT (120, 208, 240 and
277), Dual-Tap/DT (120, 277 volts),
Tri-Tap/TT (120, 277, 347 volts) 480 volt,
600 volt, 220 / 240 volt-50 Hz
50150W HPS; 70175W MH and Pulse
Start MH

US: 1-866-764-5454

Description
Suffix
Wall Mount Arm. For converting
ceiling mount luminaire to a wall
mount. ................................. N2MV-WM1
Ballast-Gard starter cut-out
switch. Prevents starter pulsing
when lamp is cycling or
inoperative; prolongs ballast and
ignitor life. Available for use with
50150 watt HPS ......................
BG
Factory Assembled. For a factory
assembled luminaire with lamp
installed........................................
FA
Instant Restrike. Enables a hot
HPS lamp to immediately
restrike after a momentary loss
of arc due to voltage fluctuation
or power outage. It has no effect
on the warm-up period of cold
lamps. Available for use with
50150W LX HPS only.................
IR
Quartz Auxiliary Lighting. Comes
to full brightness immediately
and remains lit until the HID
lamp attains 6070% of full
illumination. For non-hazardous
locations only. (Note: QTZ lamp
not included; use 100W single
ended lamp Q100DC,
Q100CL/DC, or 100Q/CL/DC)
Consult factory for top-hat
limitations.....................................
QTZ
Fused. To protect ballast and
capacitor against abnormal line
conditions..................................... S658
(Not available with /MT ballast )
(Not for use in Canada)
(Not suitable for marine
applications)
Furnished with Lamps.................. S714
Teflon Coated Globe. For
additional protection against
breakage. For use with 50100W
HPS, 70175W MH and pulse
start MH....................................... S808

Accessories:
See pages 977978 for complete listing.

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

960-961.qxp

6/13/2011

10:19 AM

Page 961

N2MV Series 50150W


High Pressure Sodium

Cl. I, Div. 2, Groups A, B, C, D


Cl. II, Groups F, G
Cl. III & Simultaneous
Presence (100W max)

Non-metallic
Champ H.I.D. Luminaires

Marine & Wet Locations


3, 3R, 4, 4X; IP56

3L

To complete the catalog #, include information in notes 1, 2 and 3 below. For guards and other optics see N2MV Series - Ordering By Components page.

Mounting
Style
Pendant Mount

Ceiling Mount
Thru-Feed

Stanchion
Mount
25 Angle

Hub
Size

Lamp
Watts

/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
11/2
11/2
11/2
11/2

50

BASIC CATALOG NUMBER


With G303 Globe and
With GR305
P33 Guard
Glass Refractor *
N2MVS2A050GP
N2MVS3A050GP
N2MVS2A070GP
N2MVS3A070GP
N2MVS2A100GP
N2MVS3A100GP
N2MVS2A150GP
N2MVS3A150GP
N2MVS2C050GP
N2MVS3C050GP
N2MVS2C070GP
N2MVS3C070GP
N2MVS2C100GP
N2MVS3C100GP
N2MVS2C150GP
N2MVS3C150GP
N2MVSJ050GP
N2MVSJ070GP
N2MVSJ100GP
N2MVSJ150GP

70
100
150
50
70
100
150
50
70
100
150

N2MVS2A050GR305
N2MVS3A050GR305
N2MVS2A070GR305
N2MVS3A070GR305
N2MVS2A100GR305
N2MVS3A100GR305
N2MVS2A150GR305
N2MVS3A150GR305
N2MVS2C050GR305
N2MVS3C050GR305
N2MVS2C070GR305
N2MVS3C070GR305
N2MVS2C100GR305
N2MVS3C100GR305
N2MVS2C150GR305
N2MVS3C150GR305
N2MVSJ050GR305
N2MVSJ070GR305
N2MVSJ100GR305
N2MVSJ150GR305

* For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. N2MVS2A050GR302
For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. N2MVS2A050GR303

1. Add voltage suffix to end of catalog number


Standard Voltage Ballasts 60Hz
NEC/UL
Voltage
Suffix

Multi Tap
/MT

Dual Tap
/DT

CEC/CSA (cUL)
120V
/120

480V
/480

Tri Tap
/TT

Dual Tap
/DT

600V CWI
/600CWI

220V 60Hz
/220

220V 50Hz
/220 50

Optional Voltage Ballasts - 50 or 60Hz


CEC/CSA (cUL) - CWI Isolated Ballasts
Voltage
Suffix

208V CWI
/208CWI

240V CWI
/240CWI

480V CWI
/480CWI

120V
/120

EXPORT
230V 50Hz
/230 50

240V 50Hz
/240 50

2. 150W HPS Luminaires: For 55V lamps - add suffix LX; for 100V lamps - add suffix CE. 50W HPS luminaire is dual tap only.
3. Options - Add the required option suffixes, see page 960, in alpha-numeric order.

3L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

961

962-963.qxp

6/13/2011

3L

10:19 AM

Page 962

N2MV Series 150175W


Pulse Start Metal Halide
Non-metallic
Champ H.I.D. Luminaires

Cl. I, Div. 2, Groups A, B, C, D


Cl. II, Groups F, G
Cl. III & Simultaneous
Presence (100W max)

Marine & Wet Locations


3, 3R, 4, 4X; IP56

To complete the catalog #, include information in notes 1 and 2 below. For guards and other optics see N2MV Series - Ordering By Components page.
BASIC CATALOG NUMBER
Mounting
Style
Pendant Mount

Ceiling Mount
Thru-Feed

Hub
Size

Lamp
Watts

With G303 Globe and


P33 Guard *

With GR305S828 Glass


Refractor

3
/4
1
3
/4
1

150

N2MVM2A150GP
N2MVM3A150GP
N2MVM2A175GP
N2MVM3A175GP

S828
S828
S828
S828

N2MVM2A150GR305
N2MVM3A150GR305
N2MVM2A175GR305
N2MVM3A175GR305

S828
S828
S828
S828

3
/4
1
3
/4
1

150

N2MVM2C150GP
N2MVM3C150GP
N2MVM2C175GP
N2MVM3C175GP

S828
S828
S828
S828

N2MVM2C150GR305
N2MVM3C150GR305
N2MVM2C175GR305
N2MVM3C175GR305

S828
S828
S828
S828

Stanchion Mount 11/2


25 Angle
11/2

175

175

150
175

N2MVMJ150GP S828
N2MVMJ175GP S828

N2MVMJ150GR305 S828
N2MVMJ175GR305 S828

* For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. N2MVM2A150GR302-S828
For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. N2MVM2A150GR303-S828

1. Add voltage suffix to end of catalog number


Standard Voltage Ballasts 60Hz
NEC/UL
Voltage
Suffix

Multi Tap
/MT

CEC/CSA (cUL)

120V
/120

480V
/480

Tri Tap
/TT

230V 50Hz
/230 50

240V 50Hz
/240 50

120V
/120

Optional Voltage Ballasts - 50 or 60Hz


EXPORT
Voltage
Suffix

220V 60Hz
/220

220V 50Hz
/220 50

3L

2. Options - Add the required option suffixes, see page 960, in alpha-numeric order.

962

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

962-963.qxp

6/13/2011

10:19 AM

Page 963

N2MV Series 70175W


Metal Halide

Cl. I, Div. 2, Groups A, B, C, D


Cl. II, Groups F, G
Cl. III & Simultaneous
Presence (100W max)

Non-metallic
Champ H.I.D. Luminaires

Marine & Wet Locations


3, 3R, 4, 4X; IP56

3L

To complete the catalog #, include information in notes 1, 2 and 3 below. For guards and other optics see N2MV Series - Ordering By Components page.
BASIC CATALOG NUMBER
Mounting
Style
Pendant Mount

Hub
Size

Lamp
Watts

With G303 Globe and


P33 Guard

With GR305 Glass


Refractor *

/4
1
3
/4
1
3
/4
1

70

N2MVM2A070GP
N2MVM3A070GP
N2MVM2A100GP
N2MVM3A100GP
N2MVM2A175GP
N2MVM3A175GP

N2MVM2A070GR305
N2MVM3A070GR305
N2MVM2A100GR305
N2MVM3A100GR305
N2MVM2A175GR305
N2MVM3A175GR305

/4
1
3
/4
1
3
/4
1

70

N2MVM2C070GP
N2MVM3C070GP
N2MVM2C100GP
N2MVM3C100GP
N2MVM2C175GP
N2MVM3C175GP

N2MVM2C070GR305
N2MVM3C070GR305
N2MVM2C100GR305
N2MVM3C100GR305
N2MVM2C175GR305
N2MVM3C175GR305

11/2
11/2
11/2

70
100
175

N2MVMJ070GP
N2MVMJ100GP
N2MVMJ175GP

N2MVMJ070GR305
N2MVMJ100GR305
N2MVMJ175GR305

Ceiling Mount
Thru-Feed

100
175

Stanchion
Mount
25 Angle

100
175

* For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. N2MVM2A070GR302
For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. N2MVM2A070GR303

1. Add voltage suffix to end of catalog number


Standard Voltage Ballasts 60Hz
NEC/UL
Voltage
Suffix

Multi Tap
/MT

120V
/120

CEC/CSA (cUL)
480V
/480

Tri Tap
/TT

120V
/120

220V 60Hz
/220

220V 50Hz
/220 50

Optional Voltage Ballasts - 50 or 60Hz


CEC/CSA (cUL) - CWI Isolated Ballasts
Voltage
Suffix

208V CWI
/208CWI

240V CWI
/240CWI

600V CWI
/600CWI

EXPORT
230V 50Hz
/230 50

240V 50Hz
/240 50

3L

2. 70W ballast not available in 480V.


3. Options - Add the required option suffixes, see page 960, in alpha-numeric order.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

963

964-965.qxp

5/30/2011

3L

9:56 AM

Page 964

N2MV Series
Ordering by Components

N2MV luminaires are available in components.


A complete luminaire consists of:
I.
N2MV Cover (Mounting Module)
II.
N2MV Ballast Housing Include voltage and required option(s)
III.
Globe, Refractor, Guard, Reflector

I. N2MV Cover (Mounting Module):


Type
Pendant

Conduit

Cat. #

/4"
1"

N2APM2
N2APM3

Ceiling

/4"
1"

N2CM2
N2CM3

Wall (Use wall bracket accessory with


Ceiling Cover)
Stanchion 25 Degree Angle

/4"
1"

N2MV WM1 and N2CM2


N2MV WM1 and N2CM3

11/2"

N2JM5

II. Ballast Housings:


Complete catalog number must have the voltage suffix (MT shown) and any options suffixes.
Lamp
Lamp Type
Watts
Cat. #
High Pressure Sodium
50
N2MVS050/MT
70
N2MVS070/MT
100
N2MVS100/MT
150
N2MVS150/MT LX
Metal Halide

70
100
175

N2MVM070/MT
N2MVM100/MT
N2MVM175/MT

3L

III. Globe, Refractors, Guards and Reflectors:


Type

Cat. #

Globe
Globe Teflon Coated
Globe Guard
Reflector Dome
Reflector Angle
Refractor Type 2
Refractor Type 3
Refractor Type 5
Refractor Guard
Large Plastic Refractor Type 2
Large Plastic Refractor Type 3
Large Plastic Refractor Type 5

G303

964

www.crouse-hinds.com

G303S808
P33
RD739
RA739
GR302
GR303
GR305
P23
PGR302
PGR303
PGR305

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

N2MV Series

3L

Family Tree

Champ H.I.D Luminaires

*Plastic refractors are non-hazardous areas only (50-100W Max.)

3L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2012 Cooper Crouse-Hinds

965

966-967.qxp

6/14/2011

3L

1:15 PM

Page 966

N2MV Series

Temperature Performance Data

Champ H.I.D Luminaires

High Pressure Sodium


40
55
50
65

T4A

70

40
55
65

T3A
T3A

T4A

T2C/T4A

T2C/T4A

75
85

75
85

100

40
55
65

T2D
T2C

T4A

T2C/T4A

85
100

150

40
55
65

T2C

85

70

40
55
65

T3C
T3B

T4

T2B/T4

75
85

100

40
55
65

T2B
T2B

T4

T2B/T4

85

150
(S828)

40
55
65

T2

175
(Includes
S828)

40
55
65

T2

3L

T3A
T3A

Metal Halide

966

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

966-967.qxp

6/14/2011

1:15 PM

Page 967

N2MV Series

3L

Dimensions and Weights

Champ H.I.D. Luminaires


Dimensions
In Inches:

Ceiling Mount

Ceiling Mount Top View

3L

Pendant Mount

25 Angle Stanchion Mount

Net Luminaire Weights (lbs.):


Luminaire
Series

Lamp
Watts

Luminaire with
Globe, Guard
(lbs.)

Lamp
Watts

Luminaire with
Globe, Guard
(lbs.)

N2VMS

50
100

23
241/16

70
150

231/16
261/8

N2MVM

70
175

21
221/4

100
250

211/16
24

Type
Lbs.
Add for mounting modules:
Pendant
11/4
Ceiling
23/4
Quad-Mount
31/2
Straight Stanchion
41/2

Wall Arm Mount

www.crouse-hinds.com

Type

Lbs.

Flexible Pendant
Wall
Angle Stanchion

11/2
41/2
31/2

Add for reflectors:


30 Angle
Dome
11/ 4
Deduct: 1 lb. for luminaire without P33 Guard.
Add: 51/ 2 lbs. for luminaire with GR305 refractor.

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

13/4

967

968-969.qxp

5/30/2011

3L

9:57 AM

Page 968

N2MV Series

Photometric Data

Champ H.I.D Luminaires


Lamp: 150W/E-23-1/2 clear high pressure sodium (HPS)
Total bare lamp lumens: 16000
All data provided is for high pressure sodium luminaires with 150W/E-23-1/2 clear lamps. Use conversion factors (multipliers) shown below for other clear lamp types and wattages.
Consult Cooper Crouse-Hinds for additional photometric data on any Champ series luminiares.

Luminaire with Globe and Dome Reflector


Multipliers (for use with
candela curve only).

Luminaire
Series

Lamp
Watts

Conversion
Factor

N2MVS

50
70
100

0.25
0.40
0.59

Isofootcandle Chart: Luminaire with


Globe and Dome Reflector

Luminaire spacing ratio: 1.90

Coefficient of Utilization
Effective Floor Cavity Reflectance 20%

3L

% Reflectance
Eff. Ceil.
Wall

Room Cavity Ratio


1
2
3

80

50
30
10

.759
.719
.683

.643
.582
.530

.551
.480
.424

.476
.400
.342

.418
.340
.283

70

50
30
10

.740
.703
.669

.627
.570
.523

.538
.471
.418

.465
.394
.338

.406
.334
.280

50

50
30
10

.703
.672
.645

.595
.548
.506

.512
.455
.408

.442
.381
.332

.388
.324
.276

30

50
30
10

.669
.646
.622

.567
.528
.492

.488
.439
.399

.422
.368
.325

.370
.314
.270

10

50
30
10

.640
.619
.600

.541
.508
.479

.466
.424
.389

.403
.356
.318

.354
.305
.265

.582

.459

.370

.299

.247

Room Cavity Ratio


6
7
8

10

80

50
30
10

.371
.296
.243

.330
.257
.208

.294
.224
.174

.267
.198
.151

.231
.164
.121

70

50
30
10

.362
.291
.238

.323
.252
.204

.288
.221
.173

.262
.195
.151

.226
.164
.121

50

50
30
10

.345
.283
.235

.309
.244
.201

.275
.215
.170

.250
.190
.148

.218
.159
.119

30

50
30
10

.331
.275
.231

.294
.239
.196

.265
.208
.168

.240
.184
.146

.209
.154
.116

10

50
30
10

.317
.266
.227

.284
.233
.193

.253
.203
.165

.231
.180
.143

.201
.150
.114

.210

.177

.149

.128

.100

968

www.crouse-hinds.com

% Reflectance
Eff. Ceil.
Wall

US: 1-866-764-5454

CAN: 1-800-265-0502

Isofootcandle Chart: Luminaire with


Globe and 30 Angle Reflector

Isofootcandle charts show illumination in footcandles on work plane


10 feet below light center. Multiply by factor shown to convert to
other mounting heights.
Height (Ft.)

Factor

Height (Ft.)

Factor

8
12
14

1.56
.694
.510

16
20

.391
.250

Copyright 2011 Cooper Crouse-Hinds

968-969.qxp

5/30/2011

9:57 AM

Page 969

NVMV Series 70-400W Ex-Protected


Luminaire for IEC and ATEX Applications

Ex nR II T...Gc
Ex t IIIC T...C Db IP66
LCIE 09 ATEX 1002
LCIE 09 ATEX 3008

Champ H.I.D. Luminaires


The Champ NVMV design is optimized for
Zone 2 gas applications (with standard
restricted breathing Ex nR protection), as
well as Zone 21 dust applications.

Applications:
NVMV Ex-Protected Luminaires are suitable
for applications in Zone 2/Zone 21/Zone
22:
In manufacturing plants, refineries,
chemical, petrochemical, and other
industrial process facilities, waste or
sewage treatment facilities, dockside and
other heavy industrial applications
In areas where combustible dusts or
fibers may be present
In areas where ignitable concentrations
of flammable gases or vapors will be
present
In installations where moisture, dirt, dust,
vibration, corrosion, and rough usage are
problematic

Features:

Certifications and
Compliances:
Application in Zone 2 area acc. IEC
60079-15
Marking to 94/9/EC: Ex II 3 G Ex nR II
T*...Gc
EC - Type Examination: LCIE 09 ATEX
1002
Application in Zone 21 and 22 areas acc.
IEC 61241-1
Marking to 94/9/EC: Ex II 2 D Ex t IIIC
T...C(*) Db IP66
EC - Type Examination: LCIE 09 ATEX
3008
General per both application
Zone 2 and 21
Temperature ambient of use: -45C to
+55C
Electromagnetic compatibility: EN
61000-6-4
Degree of protection: acc. EN 60529
IP66

NVMV 70W - 250W (Small Housing)

Standard Materials and


Finishes:
Ballast housing and mountings
copper-free aluminum
Exterior hardware stainless steel
(type 304)
Reflectors (dome and angle) Krydon
fiberglass-reinforced polyester
Globes heat and impact-resistant
glass
Guards copper-free aluminum and
stainless steel (large housing - stainless
steel only)

NVMV 250W - 400W (Large Housing)

3L

One product offering for global


applications. The Champ family has the
required IEC and ATEX certifications to
provide solutions for specification
requirements around the world.
Restricted breathing (Ex nR)
protection is standard. This provides
better T-ratings, as gases will not enter
the lamp chamber and control gear
housing.
Provides an integrated ballast with
thermal cut-off functionality incorporated
into the control gear. In the event of
abnormal temperatures or when the lamp
approaches end of life, the cut-off
functionality protects the ballast from
overheating or burning out.
Identical mounting cover for IEC and
NEC applications - regardless of
wattage, options, and accessories.
Reduce inventory costs and provide
greater flexibility for engineering
designers, customers, and distributors.
HPS lamps restrike in 10-30 seconds
with the instant restrike option (IR) should
lamp extinguish due to system voltage
drop or momentary loss. Optional builtin cut-off feature will shut off the instant
restrike to avoid continuous high energy
pulsing when lamp is inoperative or
nearing end of life.
Available with the Champ Quick-Clip.
Quick-Clip secures the housing to the
cover, providing faster, easier, and safer
luminaire installation.

3L

Technical
Specifications:
Entry
Termination
Installation
Lamp Holder
Lamp Type
Lamp Power
Control Gear

Re-lamping
Burning Position
Ingress Protection
Electrical Supply

www.crouse-hinds.com

US: 1-866-764-5454

Up to 4 x M20, M25, M32, 1/ 2" NPT and 3/ 4" NPT and 1" NPT
cable entries (11/ 2" NPT for stanchion only)
3 Core 6mm2 max. (standard); 6 x 6mm2 for looping
(available upon request)
Ceiling Mount, Wall Mount, Stanchion Mount, Pendant Mount
E27 or E40
HSE/HST (high pressure sodium lamp) and HIE
(metal halide lamp)
70W, 100W, 150W, 250W, and 400W
Integrated ballast, thermal cut-off functionality incorporated
into control gear
Access via restricted breathing lamp chamber
Base up; up to 25 off vertical
IP66 to EN 60529
220, 230, 240V 50Hz and 220, 230V 60Hz

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

969

970-971.qxp

5/30/2011

9:57 AM

Page 970

NVMV Series 70-400W Ex-Protected


Luminaire for IEC and ATEX Applications

3L

Ex nR II T...Gc
Ex t IIIC T...C Db IP66
LCIE 09 ATEX 1002
LCIE 09 ATEX 3008

Champ H.I.D. Luminaires


Ordering Information:

Example of Completed Part Number - Small Body: NVMVS1MC075POO


NVMV
Series

S
Lamp

NVMV
S = HSE/HST
Luminaire (HPS)
IEC Gear
M = HIE (MH)

1M
Entry

C
Mounting*

07
5
Wattage Voltage

1M = M20
2M = M25
3M = M32
1N = 1/2" NPT
2N = 3/4" NPT
3N = 1" NPT
5N = 1 1/2" NPT
(For Stanchion)

C = Ceiling
W = Wall
J = Stanchion

07 =
70W
10 =
100W
15 =
150W
25 =
250W

3
5
6
4
7

=
=
=
=
=

220V
230V
240V
220V
230V

/
/
/
/
/

50
50
50
60
60

Hz
Hz
Hz
Hz
Hz

P
Guard

O
Body

O = Without
Guard G34
Globe
P = G251
Globe with
P22 Alum.
Guard
S = G251
Globe with
P22 SS304
Guard

O = Small Body

O = Standard

P
Guard

L
Body

Example of Completed Part Number - Large Body: NVMVS1MC255PLO


NVMV
Series

S
Lamp

3L

NVMV
S = HSE/HST
Luminaire (HPS)
IEC Gear M = HIE (MH)

1M
Entry

C
Mounting*

25
5
Wattage Voltage

1M = M20
2M = M25
3M = M32
1N = 1/2" NPT
2N = 3/4" NPT
3N = 1" NPT
5N = 1 1/2" NPT
(For Stanchion)

C = Ceiling
W = Wall
J = Stanchion

25 =
250W
40 =
400W

3
5
6
4
7

=
=
=
=
=

220V
230V
240V
220V
230V

/
/
/
/
/

50
50
50
60
60

Hz
Hz
Hz
Hz
Hz

O = Without L = Large Body


Guard G303
Globe
P = G303
Globe with
P33 SS
Guard

Options and Accessories:


Description

Suffix

Instant restrike (100W HPS and 150W HPS) (alternative solution to dual arc lamps) /IR
Dome reflector - small housing
/RD70
30 angle reflector - small housing
/RA70
Dome reflector - large housing
/RD739
30 angle reflector - large housing
/RA739
Champ Quick-Clip
/S890

*For pendant mounting, order ceiling mount with pendant bracket accessory - please consult factory.

970

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

O = Standard

970-971.qxp

5/30/2011

9:57 AM

Page 971

3L

Temperature Performance Data

NVMV Series
Champ H.I.D. Luminaires
Temperature Performance:

Refer to temperature performance data tables (below) to select luminaire that is suitable for your area specifications. These numbers are the
maximum surface temperature of the luminaire.
Note: T3 - maximum surface temperature 200C
T4 - maximum surface temperature 135C
For example: atmospheres that contain gasoline and have an ignition temperature of 536C, any fixture with the T-rating in this table can be
used.
Atmospheres that contain diethyl ether and have an ignition temperature of 160C require a luminaire with T4 ratings.

NVMV 70W - 250W (Small Housing)


GAS (Class I, Zone 2)
Ex nR II T...Gc
Catalog Number
Example

Watts

NVMVS1MC075*00

70W

NVMVS1MC105*00

100W

Lamp
Type

Rated Lamp With


Ambient Holder G34
C
Globe
Only

HSE/HST
(HPS)
150W

NVMVS1MC255*00

250W

NVMVM1MC075*00

70W

NVMVM1MC105*00

100W

NVMVM1MC155*00

150W

NVMVM1MC255*00

250W

HIE (MH)

T4
T4
T4
T4
T4
T4
T4
T3
T3
T3
T3
T3
T4
T4
T4
T4
T4
T4
T4
T3
T3
T3
T3
T3

E27
E40
E40
E40

E27
E27
E27
E40

T4
T4
T4
T4
T4
T3
T3
T3
T3
T3
T3
T3
T4
T4
T4
T4
T4
T3
T3
T3
T3
T3
T2
T2

With
With
With
G34
G251
G34
Globe
Globe Globe
and
and
Only
Reflector Reflector
T4
T4
99C
T4
T4
109C
T4
T4
114C
T4
T4
99C
T4
T3
109C
T4
T3
114C
T3
T3
122C
T3
T3
132C
T3
T3
137C
T3
T2
168C
T2
T2
178C
T2
T2
183C
T4
T4
99C
T4
T4
109C
T4
T4
114C
T4
T4
99C
T4
T3
109C
T4
T3
114C
T3
T3
122C
T3
T3
132C
T3
T3
137C
T3
T2
168C
T2
T2
178C
T2
T2
183C

With
G251
Globe
Only
109C
119C
124C
117C
127C
132C
140C
150C
155C
174C
184C
189C
109C
119C
124C
117C
127C
132C
140C
150C
155C
194C
204C
209C

With
With
G34
G251
Globe
Globe
and
and
Reflector Reflector
104C
109C
114C
119C
119C
124C
104C
128C
114C
138C
119C
143C
140C
140C
150C
150C
155C
155C
189C
218C
199C
228C
204C
233C
104C
109C
114C
119C
119C
124C
104C
128C
114C
138C
119C
143C
140C
140C
150C
150C
155C
155C
189C
218C
199C
228C
204C
233C

Cat. No. - shown with M20 Ceiling Mount, /230V, 50 Hz.

NVMV 250W - 400W (Large Housing)

Catalog Number
Example

Watts

NVMVS1MC255*L0

250W

NVMVS1MC405*L0

400W

NVMVM1MC255*L0

250W

NVMVM1MC405*L0

400W

Lamp
Type

Rated
Ambient
C

HSE/HST
(HPS)

40
50
55
40
50
55

HIE (MH)

40
50
55
40
50
55

www.crouse-hinds.com

Lamp
Holder

E40
E40

E40
E40

GAS (Class I, Zone 2)


Ex nR II T...Gc
With G303 With G303
Globe Only Globe and
Reflector

DUST (Class II, Zone 21)


Ex t IIIC T...Db
With G303 With G303
Globe Only Globe and
Reflector

T3
T3
T3
T3
T3
T3

T3
T3
T3
T3
T3
T3

137C
147C
152C
159C
169C
174C

137C
147C
152C
175C
185C
190C

T3
T3
T3
T3
T3
T3

T3
T3
T3
T3
T2
T2

137C
147C
152C
159C
169C
174C

137C
147C
152C
193C
203C
208C

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

971

3L

NVMVS1MC155*00

40
50
55
40
50
55
40
50
55
40
50
55
40
50
55
40
50
55
40
50
55
40
50
55

With
G251
Globe
Only

DUST (Class II, Zone 21)


Ex t IIIC T...Db

972-973.qxp

5/30/2011

9:58 AM

Page 972

NVMV Series

3L

Dimensions & Weights

Champ H.I.D. Luminaires

3L

Dimensions:

972

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

972-973.qxp

5/30/2011

9:58 AM

Page 973

NVMV Series

3L

Photometric Data

Champ H.I.D. Luminaires


Photometry - Large Housing:

3L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

973

974-975.qxp

3L

5/30/2011

9:59 AM

Page 974

Photometric Data

NVMV Series
Champ H.I.D. Luminaires

3L

Photometry - Large Housing:

974

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

974-975.qxp

5/30/2011

9:59 AM

Page 975

NVMV Series

3L

Photometric Data

Champ H.I.D. Luminaires


Photometry - Small Housing:

3L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

975

976-977.qxp

3L

5/30/2011

9:59 AM

Page 976

NVMV Series

Photometric Data

Champ H.I.D. Luminaires

3L

Photometry - Small Housing:

976

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

924-925.qxp

6/13/2011

3L

10:12 AM

Page 924

VMV Series 50175W


Champ H.I.D. Luminaires

Cl. I, Div. 2, Groups A, B, C, D


Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

Applications:

Options:

VMV series Champ luminaires are used:


In manufacturing plants, refineries,
chemical, petrochemical, and other
industrial process facilities, waste or
sewage treatment facilities, offshore,
dockside, and harbor installations, and
other heavy industrial applications
In areas in which ignitible concentrations
of flammable gases or vapors will be
present only due to abnormal, unusual,
or accidental conditions
Where combustible dusts are present
In marine applications where water
spray and corrosive atmospheres are
considerations
In elevated ambient temperatures often
found in industrial applications
In installations where moisture, dirt,
dust, vibration, corrosion, and rough
usage are problems
Wherever the damaging effects of water,
wind, snow, sleet, hot sun, or any
combination of these elements are found

3L

Features:
Compact, lightweight design is ideal for
medium and low mounting heights
Cast copper-free aluminum construction
(less than 0.4 of 1% copper) and epoxy
powder finish provide excellent resistance
to corrosion
Seven mounting arrangements to suit any
lighting layout pendant, flexible pendant,
ceiling, wall bracket, angle stanchion,
straight stanchion, and quad-mount
Wide range of light sources and wattages
to meet specifiers' needs: 50, 70, 100, and
150 watt high pressure sodium (HPS); 70,
100, 175 watt metal halide (MH and Pulse
Start MH)
Hinged ballast housing for ease of
installation and maintenance
Wide choice of photometric distributions.
Glass globes, refractors and compact
refractors available for all wattage
luminaires; plastic refractors (for nonhazardous applications only) for 50100
watt luminaires
All luminaires are designed to perform in a
40C ambient temperature. Selected
luminaires are suitable for ambient
temperatures up to 65C
Superior gasketing seals between the
mounting module, housing, and optical
assembly for optimum performance in wet
and corrosive environments
Hubs with an integral conduit stop and
bushing to help prevent damage to field
wiring during installation
Low ambient capability to (40C)
Dome and 30 angle reflectors made of
bright white Krydon material provide
superior reflectivity, with twist-on feature
requiring no tools or additional hardware.
Will not chip, peel, dent, rust, or corrode
Grounding wire for safety
High power factor ballasts (Min P.F. 90%)
and available in a variety of voltages to
meet local area requirements
Mogul base porcelain lamp socket
924

www.crouse-hinds.com

Cl. II, Groups E, F, G, Cl. III &


Simultaneous Presence
(HPS 50W, 70W)
Marine & Wet Locations
3, 3R, 4, 4X; IP56 to IP66

The following special options are available


from the factory by adding suffix to luminaire
Cat. No.:
Description
Suffix
Factory Sealed Champs .......................
S865
Class I, Division 2 & Zone 2
Provides T3 code without
conduit or cable seals
Restricted breathing/Non-sparking
Restricted Breathing Construction .......
S826
Class I, Division 2 & Zone 2
Suitabilty
Cooler Operating Temperatures
(T-Numbers)
Certified for IEC Zone 2........................ S826TB
Furnished with terminal block,
crimp terminals and dedicated
voltage ballasts (no MT, DT or TT)
Fused to protect ballast and
capacitors against abnormal line
Certifications and
conditions ............................................. S658*
Compliances:
(Not available with /MT Ballast)
(Not for use in Canada)
NEC & CEC:
(Not suitable for marine applications)
Class I, Division 2, Groups A, B, C, D
Quick-Clip - Holds weight of
HPS 50W, 70W Class II, Class III &
housing when closed. No need to
Simultaneous Presence (Class I,
support luminaire while screwing
Division 2 and Class II)
the housing to the cover.......................
S890
Class I, Zone 2
Ballast-Gard starter cut-out
IEC:
switch prevents starter pulsing
when lamp is cycling or inoperative;
Zone 2 Ex nR IIC
prolongs ballast and
UL Standards:
ignitor life. Available for use with
844 Hazardous (Classified) Locations
50150W LX HPS only .........................
BG
1598 Luminaires
Instant restrike enables a hot HPS
1598A Marine Locations
lamp to immediately restrike after a
momentary loss arc due to voltage
CSA Standards:
fluctuation or power outage. It has
C22.2 No. 137
no effect on the warm-up period of
IEC Standards:
cold lamps. Available for use with
60079-15
50150W LX HPS only .........................
IR
Quartz auxiliary lighting comes to
Standard Materials:
full brightness immediately and
remains lit until the HID lamp attains
Ballast housings and mountings
6070% of full illumination. For noncopper-free aluminum (less than 0.4 of
hazardous locations only. Must use
1%)
R2, R3 and R5 refractors......................
QTZ
Exterior hardware stainless steel
Refractor Mount - For ballast
Reflectors (dome and angle) Krydon
housing only. Used with R2, R3
fiberglass-reinforced polyester material
and R5 refractors ..................................
RM
Globes heat and impact resistant
Stainless steel insert top hat
internally fluted glass
with stainless steel threaded insert
Refractors glass (50175 watts); plastic to attach ballast housing ......................
S806
50100 watts), for non-hazardous
TEFLON coating on globe for
applications
increased shatter protection.................
S808
G24 only. T-Numbers not
Guards: Globe copper-free aluminum
affected
Refractor stainless steel
Factory assembled with H.I.D.
lamps installed for additional labor
Standard Finishes:
savings..................................................
FA
Copper-free aluminum epoxy powder Note: BG and IR options cannot be used together. IR and
coat
QTZ options cannot be used together.
Krydon material high reflectance white
Accessories:
Stainless steel natural
See pages 977978 for complete listing.

Electrical Ratings:

120, 208, 240, 277, 347, 480, 600, Multitap (120, 208, 240 and 277)
50 to 150W HPS; 70 to 175W MH

US: 1-866-764-5454

CAN: 1-800-265-0502

TEFLON is a registered trademark of E.I. duPont Co.


*When ordering fuses for luminaires, option S658, you must
specify the operating voltage. S658 cannot be ordered with
/MT in the catalog number.

Copyright 2011 Cooper Crouse-Hinds

924-925.qxp

6/13/2011

10:12 AM

Page 925

Cl. I, Div. 2, Groups A, B, C, D


Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

VMV Series 50150W


High Pressure Sodium
Champ H.I.D. Luminaires

Cl. II, Groups E, F, G, Cl. III &


Simultaneous Presence
(50W, 70W)
Marine & Wet Locations
3, 3R, 4, 4X; IP66

3L

To complete the catalog #, include information in notes 1, 2 and 3 below. For guards and other optics see VMV Series - Ordering By
Components page.
BASIC CATALOG NUMBER
Mounting
Hub
Lamp
With G24 Globe
With G241 Type I
With R5 Glass
Style
Size
Watts
and P21 Guard
Compact Refractor *
Refractor
50

3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
3
/4
3
/4
3
/4

50

Stanchion
Mount
25 Angle

Stanchion
Mount
Straight

Flexible
Pendant Mount

Ceiling Mount
Thru-Feed

Wall Mount
Thru-Feed

Quad-Mount
Pendant,
Adjustable,
Thru-Feed,
25 Angle,
12 Angle

VMVS2A050GP
VMVS3A050GP
VMVS2A070GP
VMVS3A070GP
VMVS2A100GP
VMVS3A100GP
VMVS2A150GP
VMVS3A150GP
VMVS2HA050GP
VMVS2HA070GP
VMVS2HA100GP
VMVS2HA150GP

VMVS2A050G241
VMVS3A050G241
VMVS2A070G241
VMVS3A070G241
VMVS2A100G241
VMVS3A100G241
VMVS2A150G241
VMVS3A150G241
VMVS2HA050G241
VMVS2HA070G241
VMVS2HA100G241
VMVS2HA150G241

VMVS2A050R5
VMVS3A050R5
VMVS2A070R5
VMVS3A070R5
VMVS2A100R5
VMVS3A100R5
VMVS2A150R5
VMVS3A150R5
VMVS2HA050R5
VMVS2HA070R5
VMVS2HA100R5
VMVS2HA150R5

50
70
100
150

VMVS2C050GP
VMVS3C050GP
VMVS2C070GP
VMVS3C070GP
VMVS2C100GP
VMVS3C100GP
VMVS2C150GP
VMVS3C150GP
VMVS2TW050GP
VMVS3TW050GP
VMVS2TW070GP
VMVS3TW070GP
VMVS2TW100GP
VMVS3TW100GP
VMVS2TW150GP
VMVS3TW150GP
VMVS25Q050GP
VMVS25Q070GP
VMVS25Q100GP
VMVS25Q150GP

VMVS2C050G241
VMVS3C050G241
VMVS2C070G241
VMVS3C070G241
VMVS2C100G241
VMVS3C100G241
VMVS2C150G241
VMVS3C150G241
VMVS2TW050G241
VMVS3TW050G241
VMVS2TW070G241
VMVS3TW070G241
VMVS2TW100G241
VMVS3TW100G241
VMVS2TW150G241
VMVS3TW150G241
VMVS25Q050G241
VMVS25Q070G241
VMVS25Q100G241
VMVS25Q150G241

VMVS2C050R5
VMVS3C050R5
VMVS2C070R5
VMVS3C070R5
VMVS2C100R5
VMVS3C100R5
VMVS2C150R5
VMVS3C150R5
VMVS2TW050R5
VMVS3TW050R5
VMVS2TW070R5
VMVS3TW070R5
VMVS2TW100R5
VMVS3TW100R5
VMVS2TW150R5
VMVS3TW150R5
VMVS25Q050R5
VMVS25Q070R5
VMVS25Q100R5
VMVS25Q150R5

11/2
11/2
11/2
11/2

50
70
100
150

VMVSJ050GP
VMVSJ070GP
VMVSJ100GP
VMVSJ150GP

VMVSJ050G241
VMVSJ070G241
VMVSJ100G241
VMVSJ150G241

VMVSJ050R5
VMVSJ070R5
VMVSJ100R5
VMVSJ150R5

11/2
11/2
11/2
11/2

50
70
100
150

VMVSP050GP
VMVSP070GP
VMVSP100GP
VMVSP150GP

VMVSP050G241
VMVSP070G241
VMVSP100G241
VMVSP150G241

VMVSP050R5
VMVSP070R5
VMVSP100R5
VMVSP150R5

70
100
150
50
70
100
150

70
100
150
50
70
100
150

3L

3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
3
/4
3
/4
3
/4

Pendant Mount

* For G243 Type III Compact Refractor, change "241" at end of catalog number to "243". Ex. VMVS2A050G243
For G245 Type V Compact Refractor, change "241" at end of catalog number to "245". Ex. VMVS2A050G245
For R2 Glass Refractor, change "R5" at end of catalog number to "R2". Ex. VMVS2A050R2.
For R3 Glass Refractor, change "R5" at end of catalog number to "R3". Ex. VMVS2A050R3.
2. 150W HPS Luminaires: For 55V lamps - add suffix LX; for 100V lamps
- add suffix CE. 50W HPS luminaire is dual tap only.

1. Add voltage suffix to end of catalog number


Standard Voltage Ballasts 60Hz
NEC/UL

CEC/CSA (cUL)

Voltage
Multi Tap
Dual Tap
120V
Suffix
/MT
/DT
/120
Multi Tap and Dual Tap ballasts are powered for 277V

480V
/480

Tri Tap
/TT

Dual Tap
/DT

600V CWI
/600CWI

220V 60Hz
/220

220V 50Hz
/220 50

Optional Voltage Ballasts - 50 or 60Hz


CEC/CSA (cUL) - CWI Isolated Ballasts
Voltage
Suffix

208V CWI
/208CWI

240V CWI
/240CWI

480V CWI
/480CWI

120V
/120

3. Options - Add the required option suffixes, see page 924,


in alpha-numeric order.

EXPORT

www.crouse-hinds.com

US: 1-866-764-5454

240V 50Hz
/240 50

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

925

926-927.qxp

6/13/2011

3L

10:13 AM

Page 926

VMV Series 150175W


Pulse Start Metal Halide

Marine & Wet Locations


3, 3R, 4, 4X; IP66

Cl. I, Div. 2, Groups A, B, C, D


Restricted Breathing Cl. I, Div. 2
& Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

Champ H.I.D. Luminaires

To complete the catalog #, include information in note 1 below. For guards and other optics see VMV Series - Ordering By Components page.

Mounting
Style

Hub
Size

Lamp
Watts

With G24 Globe


and P21 Guard

Pendant Mount

3
/4
1
3
/4
1

150

VMVM2A150GP
VMVM3A150GP
VMVM2A175GP
VMVM3A175GP

S828
S828
S828
S828

VMVM2A150G245
VMVM3A150G245
VMVM2A175G245
VMVM3A175G245

S828
S828
S828
S828

/4
/4

150
175

VMVM2HA150GP S828
VMVM2HA175GP S828

VMVM2HA150G245 S828
VMVM2HA175G245 S828

VMVM2HA150R5 S828
VMVM2HA175R5 S828

Ceiling Mount
Thru-Feed

3
/4
1
3
/4
1

150

VMVM2C150GP
VMVM3C150GP
VMVM2C175GP
VMVM3C175GP

VMVM2C150G245
VMVM3C150G245
VMVM2C175G245
VMVM3C175G245

VMVM2C150R5
VMVM3C150R5
VMVM2C175R5
VMVM3C175R5

3
/4
1
3
/4
1

150

175

S828
S828
S828
S828

VMVM2TW150GP
VMVM3TW150GP
VMVM2TW175GP
VMVM3TW175GP

175

S828
S828
S828
S828

S828
S828
S828
S828

VMVM2TW150G245
VMVM3TW150G245
VMVM2TW175G245
VMVM3TW175G245

S828
S828
S828
S828

VMVM2TW150R5
VMVM3TW150R5
VMVM2TW175R5
VMVM3TW175R5

S828
S828
S828
S828

/4
/4

150
175

VMVM25Q150GP S828
VMVM25Q175GP S828

VMVM25Q150G245 S828
VMVM25Q175G245 S828

VMVM25Q150R5 S828
VMVM25Q175R5 S828

Stanchion
Mount
25 Angle

11/2
11/2

150
175

VMVMJ150GP S828
VMVMJ175GP S828

VMVMJ150G245 S828
VMVMJ175G245 S828

VMVMJ150R5 S828
VMVMJ175R5 S828

Stanchion
Mount
Straight

11/2
11/2

150
175

VMVMP150GP S828
VMVMP175GP S828

VMVMP150G245 S828
VMVMP175G245 S828

VMVMP150R5 S828
VMVMP175R5 S828

1. Add voltage suffix to end of catalog number


Standard Voltage Ballasts 60Hz
NEC/UL
Multi Tap
/MT

120V
/120

480V
/480

CEC/CSA (cUL)
Tri Tap
/TT

120V
/120

Optional Voltage Ballasts - 50 or 60Hz


EXPORT

926

S828
S828
S828
S828

Quad-Mount
Pendant,
Adjustable ThruFeed, 25 Angle,
121/ 2 Angle

For R2 Glass Refractor, change "R5" at end of catalog number to "R2". Ex. VMVM2A150R2-S828.
For R3 Glass Refractor, change "R5" at end of catalog number to "R3". Ex. VMVM2A150R3-S828.

Voltage
Suffix

S828
S828
S828
S828

* For G241 Type I Compact Refractor, change "245" at end of catalog number to "241". Ex. VMVM2A150G241-S828
For G243 Type III Compact Refractor, change "245" at end of catalog number to "243". Ex. VMVM2A150G243-S828

Voltage
Suffix

VMVM2A150R5
VMVM3A150R5
VMVM2A175R5
VMVM3A175R5

Flexible
Pendant Mount

Wall Mount
Thru-Feed

3L

175

BASIC CATALOG NUMBER


With G245 Type V
With R5 Glass
Compact Refractor *
Refractor

220V 60Hz
/220

www.crouse-hinds.com

220V 50Hz
/220 50

US: 1-866-764-5454

230V 50Hz
/230 50

CAN: 1-800-265-0502

240V 50Hz
/240 50

Copyright 2011 Cooper Crouse-Hinds

926-927.qxp

6/13/2011

10:13 AM

Page 927

Cl. I, Div. 2, Groups A, B, C, D


Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2 (Suffix S826TB)

VMV Series 70175W


Metal Halide
Champ H.I.D. Luminaires

Marine & Wet Locations


3, 3R, 4, 4X; IP66

3L

To complete the catalog #, include information in notes 1, 2 and 3 below. For guards and other optics see VMV Series - Ordering By Components page.

Mounting
Style

Hub
Size

Pendant Mount

3
/4
1
3
/4
1
3
/4
1

Lamp
Watts

With G24 Globe


and P21 Guard

BASIC CATALOG NUMBER


With G241 Type I
With R5 Glass
Compact Refractor *
Refractor

70

VMVM2A070GP
VMVM3A070GP
VMVM2A100GP
VMVM3A100GP
VMVM2A175GP
VMVM3A175GP

VMVM2A070G241
VMVM3A070G241
VMVM2A100G241
VMVM3A100G241
VMVM2A175G241
VMVM3A175G241

VMVM2A070R5
VMVM3A070R5
VMVM2A100R5
VMVM3A100R5
VMVM2A175R5
VMVM3A175R5

100
175

Flexible
Pendant Mount

/4
/4
3
/4

70
100
175

VMVM2HA070GP
VMVM2HA100GP
VMVM2HA175GP

VMVM2HA070G241
VMVM2HA100G241
VMVM2HA175G241

VMVM2HA070R5
VMVM2HA100R5
VMVM2HA175R5

Ceiling Mount
Thru-Feed

3
/4
1
3
/4
1
3
/4
1

70

VMVM2C070GP
VMVM3C070GP
VMVM2C100GP
VMVM3C100GP
VMVM2C175GP
VMVM3C175GP

VMVM2C070G241
VMVM3C070G241
VMVM2C100G241
VMVM3C100G241
VMVM2C175G241
VMVM3C175G241

VMVM2C070R5
VMVM3C070R5
VMVM2C100R5
VMVM3C100R5
VMVM2C175R5
VMVM3C175R5

VMVM2TW070GP
VMVM3TW070GP
VMVM2TW100GP
VMVM3TW100GP
VMVM2TW175GP
VMVM3TW175GP

VMVM2TW070G241
VMVM3TW070G241
VMVM2TW100G241
VMVM3TW100G241
VMVM2TW175G241
VMVM3TW175G241

VMVM2TW070R5
VMVM3TW070R5
VMVM2TW100R5
VMVM3TW100R5
VMVM2TW175R5
VMVM3TW175R5

Wall Mount
Thru-Feed

3
/4
1
3
/4
1
3
/4
1

Quad-Mount

100
175

70
100
175

/4
/4
3
/4

70
100
175

VMVM25Q070GP
VMVM25Q100GP
VMVM25Q175GP

VMVM25Q070G241
VMVM25Q100G241
VMVM25Q175G241

VMVM25Q070R5
VMVM25Q100R5
VMVM25Q175R5

Stanchion
Mount
25 Angle

11/2
11/2
11/2

70
100
175

VMVMJ070GP
VMVMJ100GP
VMVMJ175GP

VMVMJ070G241
VMVMJ100G241
VMVMJ175G241

VMVMJ070R5
VMVMJ100R5
VMVMJ175R5

Stanchion
Mount
Straight

11/2
11/2
11/2

70
100
175

VMVMP070GP
VMVMP100GP
VMVMP175GP

VMVMP070G241
VMVMP100G241
VMVMP175G241

VMVMP070R5
VMVMP100R5
VMVMP175R5

3L

Pendant,
Adjustable
Thru-Feed,
25 Angle,
121/ 2 Angle

* For G243 Type III Compact Refractor, change "241" at end of catalog number to "243". Ex. VMVM2A070G243
For G245 Type V Compact Refractor, change "241" at end of catalog number to "245". Ex. VMVM2A070G245
For R2 Glass Refractor, change "R5" at end of catalog number to "R2". Ex. VMVM2A070R2.
For R3 Glass Refractor, change "R5" at end of catalog number to "R3". Ex. VMVM2A070R3.
1. Add voltage suffix to end of catalog number
Standard Voltage Ballasts 60Hz

2. 70W ballast not available in 480V.


NEC/UL

Voltage
Suffix

Multi Tap
/MT

120V
/120

480V
/480

Tri Tap
/TT

Optional Voltage Ballasts - 50 or 60Hz


CEC/CSA (cUL) - CWI Isolated Ballasts
Voltage
Suffix

208V CWI
/208CWI

480V CWI
/240CWI

3. Options - Add the required option suffixes, see page 924,


in alpha-numeric order.

CEC/CSA (cUL)

600V CWI
/600CWI

120V
/120

EXPORT
220V 60Hz
/220

www.crouse-hinds.com

220V 50Hz
/220 50

230V 50Hz
/230 50

US: 1-866-764-5454

240V 50Hz
/240 50

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

927

928-929.qxp

5/30/2011

9:37 AM

Page 928

VMV Series
Ordering by Components

3L

VMV luminaires are available in components.


A complete luminaire consists of:
I.

Champ Cover (Mounting Module)

II.

VMV Ballast Housing Include voltage and required option(s)

III.

Optical & Guard components Globe, Reflector, Refractor, Guard

I. Champ Cover (Mounting Module):


Type
Pendant

Conduit

Cat. #

/4"
1"

APM2
APM3

Flexible Pendant

/4"

HPM2

Ceiling

/4"
1"

CM2
CM3

Wall

3
/4"
1"

TWM2
TWM3

Stanchion 25 Degree Angle

11/2"

JM5

Stanchion Straight

1 /2"

PM5

Quad-Mount

/4"

QM25

II. Ballast Housings:


Complete catalog number must have the voltage suffix (MT shown) and any options suffixes.
Cat. #
For Globe and
Compact Refractor

Cat. #
For Large
Refractor

Lamp Watts

High
Pressure
Sodium

50
70
100
150

VMVS050/DT
VMVS070/MT
VMVS100/MT
VMVS150/MT LX

VMVS050/MT RM
VMVS070/MT RM
VMVS100/MT RM
VMVS150/MT LX RM

Metal
Halide

70
100
175

VMVM070/MT
VMVM100/MT
VMVM175/MT

VMVM070/TT RM
VMVM100/MT RM
VMVM175/MT RM

3L

Lamp Type

III. Globe, Reflectors, Refractors, Guards:


Type

Cat. #

Globe
Globe Teflon Coated
Globe Guard
Reflector Dome
Reflector Angle
Compact Refractor Type 1
Compact Refractor Type 3
Compact Refractor Type 5
Compact Refractor Guard
Large Refractor Type 2
Large Refractor Type 3
Large Refractor Type 5
Large Refractor Guard
Large Plastic Refractor Type 2
Large Plastic Refractor Type 3
Large Plastic Refractor Type 5

G24
G24 S808
P21
RD70
RA70

928

www.crouse-hinds.com

G241
G243
G245
P241
R2
R3
R5
P23
PR2
PR3
PR5

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

928-929.qxp

5/30/2011

9:37 AM

Page 929

VMV Series

3L

Family Tree

Champ H.I.D. Luminaires

3L

*Plastic refractors are for non-hazardous areas only (50100W Max.)

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

929

3L

Temperature Performance Data

VMV Series
Champ H.I.D. Luminaires

Lamp

Cat. #

Rated
Ambient
C

Class II,
Division 1

Class I, Division 2
Globe
(G24,
G241,
G245)

Class I, Zone 2

Supply Wire
Suitable For C

Globe
Globe (G24)
Restricted
(G24) w/
w/ or w/o Simultaneous Breathing Suffix
Factory
Globe
Reflector Refractor
Reflector
Presence
S826 w/
Sealed
(G24, Refractor
(RA70 or (R2, R3,
(RA70 or
Class I, Div. 2
Globe (G24,
Suffix S865 G241, (R2, R3,
RD70)
or R5)
Group
RD70)
Class II, Div. 2
G241, G245)
AEx nA nR II G245)
or R5)

Wattage

Type

VMVM70
VMVM70
VMVM70
VMVM100
VMVM100 S849
VMVM100
VMVM150
VMVM175

70
70
70
100
100
100
150
175

MH
MH
MH
MH
MH
MH
MH
MH

40
55
65
40
40
55
40
40

T3A
T3
T3
T2D
T2
T2D
T2A
T2A

T3A
T3
T3
T2D
T2
T2D
T2A
T2A

T3A
T3
T3
T2D
T2
T2D
T2B
T2B

VMVS50
VMVS50
VMVS50
VMVS70
VMVS70
VMVS100
VMVS100
VMVS150
VMVS150

50
50
50
70
70
100
100
150
150

HPS
HPS
HPS
HPS
HPS
HPS
HPS
HPS
HPS

40
55
65
40
55
40
55
40
55

T3A
T3A
T3
T3
T3
T2C
T2B
T2A
T2

T3A
T3A
T3
T3
T3
T2C
T2B
T2A
T2

T3B
T3A
T3
T3B
T3
T2D
T2C
T2B
T2A

VMVIG055
VMVIG055

55
55

Induction
Induction

40
55

T2C
T2C

T2C
T2C

EFG
EFG
EFG
EFG
EFG
EFG
EFG

T4A
T4
T4
T3C
T3C
T3A

T3A
T3
T2D
T2C
T2B
T2A

T5
T4
T4
T4
T4
T4
T3
T3

T3
T3
T3
T3
T3
T3
T3
T3

90
90
90
90
75
90
90
90

90
90
90
90
75
90
90
90

T5
T5
T5
T4
T4
T4
T3
T3
T3

T3
T3
T3
T3
T3
T3
T3
T3
T3

75
75
75
75
90
90
105
90
105

65
75
75
65
90
75
90
85
105

T6
T5

65
65

The Class I, Division 2 T-codes apply to luminaires without the restricted breathing (S826) or factory sealed (S865) options. These luminaires
are listed to UL 844. UL844 specifies how the temperatures are measured.

3L

The Class I, Zone 2 T-codes are for luminaires that are additionally listed to UL 60079-15 that specify a different method for measuring
temperatures. Since NEC 501.1 states that equipment "for use in Class I, Zone 0, 1, or 2 locations shall be permitted in Class I, Division 2
locations" then these luminaires are suitable for Class I, Division 2 but with cooler temperature ratings. They also have the advantage of
meeting the more rigorous mechanical tests of UL 844.

930

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2012 Cooper Crouse-Hinds

930-931.qxp

5/30/2011

9:38 AM

Page 931

Dimensions and Weights

VMV Series

3L

Champ H.I.D. Luminaires

Dimensions

Net Luminaire Weights:

In Inches:

Lamp Watts
Luminaire Series
50
70
Luminaire with Globe, Guards (lbs.):
VMVS
131/2
141/2
VMVM
13
Luminaire with Glass Refractor (lbs.):
VMVS
213/4
223/4
VMVM
21

Pendant Mount

Ceiling Mount Top View

Type
Lbs.
Add for mounting modules:
Pendant
11/4
Flexible Pendant
11/2
Ceiling
23/4
Wall
41/2
Add for reflectors:
Dome

11/2

100

150

141/2
131/4

141/2

223/4
211/2

223/4

175

151/2

233/4

Type

Lbs.

Quad-Mount
Angle Stanchion
Straight Stanchion

31/ 2
31/ 2
41/ 2

30 Angle

11/ 2

Deduct: /2" lb. for fixture without P21 Guard


1

Quad-Mount

Ceiling Mount

25 Angle Stanchion Mount

Straight Stanchion Mount

Luminaire With: Refractors,


Guard

3L

Wall Mount

Compact Refractor

Globe, Guard, Reflectors

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

931

932-933.qxp

5/30/2011

9:38 AM

Page 932

VMV Series

3L

Photometric Data

Champ H.I.D. Luminaires


Lamp: 100W/E 231/2 high pressure sodium (HPS)
Total bare lamp lumens: 9500
NOTE: All data provided is for high pressure sodium luminaires with 100W/E23-1/2 clear lamps. Use conversion factors (multipliers) shown below for other clear lamp types and wattages.
Consult Cooper Crouse-Hinds for additional photometric data on any Champ Series luminaire.

Luminaire with Globe and Dome Reflector


Multipliers (for use with
candela curve only).
ConLuminaire Lamp version
Series
Watts Factor
VMVS

50
70
150

Isofootcandle Chart: Luminaire with Globe and


Dome Reflector

0.42
0.67
1.68

Luminaire spacing ratio: 1.85

Coefficient of Utilization
Effective Floor Cavity Reflectance 20%

3L

% Reflectance
Eff. Ceil.
Wall

Room Cavity Ratio


1
2
3

80

50
30
10

.823
.784
.749

.707
.646
.594

.610
.538
.482

.529
.451
.391

.464
.384
.324

70

50
30
10

.804
.767
.734

.690
.633
.587

.597
.530
.477

.517
.445
.388

.452
.377
.321

50

50
30
10

.765
.735
.709

.658
.611
.569

.571
.513
.466

.494
.431
.381

.434
.368
.318

30

50
30
10

.731
.708
.685

.629
.591
.555

.546
.497
.456

.473
.419
.375

.416
.357
.312

10

50
30
10

.701
.681
.662

.603
.569
.541

.524
.482
.446

.454
.406
.367

.399
.348
.307

.644

.521

.427

.348

.288

Room Cavity Ratio


6
7
8

10

80

50
30
10

.412
.334
.278

.366
.290
.239

.326
.253
.201

.296
.224
.175

.258
.187
.142

70

50
30
10

.403
.329
.274

.359
.285
.235

.320
.250
.200

.291
.221
.174

.252
.187
.142

50

50
30
10

.386
.320
.271

.344
.277
.231

.307
.244
.197

.279
.216
.172

.244
.182
.140

30

50
30
10

.371
.312
.267

.329
.272
.227

.296
.237
.195

.269
.210
.170

.235
.178
.137

Isofootcandle charts show illumination in footcandles on work plane


10 feet below light center. Multiply by factor shown to convert to
other mounting heights.

50
30
10

.357
.304
.263

.319
.266
.224

.285
.232
.192

.260
.206
.167

.227
.173
.135

Height (Ft.)

Factor

Height (Ft.)

Factor

10

0.51
0.39

.245

.207

.176

.152

.120

2.78
1.56
0.70

14
16

6
8
12

932

www.crouse-hinds.com

% Reflectance
Eff. Ceil.
Wall

US: 1-866-764-5454

CAN: 1-800-265-0502

Isofootcandle Chart: Luminaire with Globe and 30


Angle Reflector

Copyright 2011 Cooper Crouse-Hinds

932-933.qxp

5/30/2011

9:38 AM

Page 933

VMV Series

Photometric Data

3L

Champ H.I.D. Luminaires


Lamp: 100W/E0 231/2 high pressure sodium (HPS)

Coefficient of Utilization
Effective Floor Cavity Reflectance 20%

Luminaire with I.E.S. Type V Glass Refractor

Room Cavity Ratio


1
2
3

80

50
30
10

.848
.796
.750

.709
.631
.566

.597
.509
.439

.508
.414
.341

.437
.343
.271

70

Conversion
Factor

50
30
10

.818
.770
.726

.682
.611
.552

.576
.493
.428

.489
.402
.334

.419
.331
.264

50

0.42
0.67
1.68

50
30
10

.759
.720
.685

.632
.574
.521

.533
.464
.407

.451
.377
.318

.389
.312
.253

30

50
30
10

.706
.675
.645

.586
.538
.495

.493
.435
.386

.417
.354
.302

.359
.291
.240

10

50
30
10

.658
.632
.608

.544
.504
.469

.457
.408
.366

.385
.331
.286

.331
.274
.227

.581

.441

.340

.260

.203

NOTE: Photometric data was


developed using a 100 watt
clear high pressure sodium
lamp (9500 lumens). For other
clear lamps, use the following
conversion factors (multipliers):
Luminaire Lamp
Series
Watts
VMVS

50
70
150

% Reflectance
Eff. Ceil.
Wall

Luminaire spacing ratio: 2.0

% Reflectance
Eff. Ceil.
Wall

10

80

50
30
10

.384
.292
.226

.337
.249
.189

.299
.214
.154

.272
.189
.132

.238
.159
.103

70

50
30
10

.369
.283
.218

.325
.240
.182

.288
.203
.150

.262
.183
.130

.229
.156
.105

50

50
30
10

.341
.266
.209

.301
.225
.173

.266
.195
.143

.243
.173
.124

.214
.146
.099

30

50
30
10

.316
.249
.199

.277
.213
.163

.248
.182
.136

.225
.161
.117

.198
.136
.093

10

50
30
10

.292
.233
.188

.258
.200
.154

.223
.171
.128

.209
.151
.110

.134
.127
.087

.165

.133

.108

.091

.070

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

3L

www.crouse-hinds.com

Room Cavity Ratio


6
7
8

933

950-951.qxp

6/13/2011

10:17 AM

Page 951

VMV High Wattage Series


200-400W For Medium and
High Mounting Heights

Cl. I, Div. 2, Groups A, B, C, D


Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

Champ H.I.D. Luminaires

Cl. II, Groups E, F, G; Cl. III &


Simultaneous Presence
(with Glass Refractor)
Marine (with Globe or Glass
Refractor) & Wet Locations
3, 3R, 4, 4X; IP66

Applications:

Standard Materials:

VMV high wattage series Champ luminaires are used:


In manufacturing plants, refineries, chemical, petrochemical, and
other industrial process facilities, waste or sewage treatment
facilities, and other heavy industrial applications
In applications involving medium and high mounting heights
In applications where energy-efficient, high lumen output is
required
In areas in which ignitible concentrations of flammable gases or
vapors will be present only due to abnormal, unusual, or accidental
conditions
In marine applications where water spray and corrosive
atmospheres are considerations
In elevated ambient temperatures often found in industrial
applications
In installations where moisture, dirt, dust, vibration, corrosion and
rough usage are problems
Wherever the damaging effects of water, wind, snow, sleet, hot
sun, or any combination of these elements, are problems

Ballast housings and mountings


copper-free aluminum (less than 0.4
of 1%)
Exterior hardware and guards
stainless steel
Reflectors (dome and angle)
Krydon fiberglass-reinforced
polyester material
Globes heat and impact resistant
internally fluted glass
Refractors glass
Reflector lens spun Alzak
aluminum, tempered glass, stainless
steel door frame

Features:

Certifications and Compliances:


NEC/CEC:
Class I, Division 2, Groups A, B, C, D
With Glass Refractor - Class II, Class III & Simultaneous Presence
(Class I, Division 2 and Class II)
Class I, Zone 2
IEC:
Zone 2 Ex nR IIC
UL Standards:
844 Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations
CSA Standards:
C22.2 No. 137
IEC Standards:
60079-15
www.crouse-hinds.com

Standard Finishes:

Copper-free aluminum epoxy powder coat


Alzak aluminum natural
Stainless steel natural
Krydon material high reflectance white

Options:
The following special options are available from the factory by
adding suffix to luminaire Cat. No.:
Description
Suffix
Restricted Breathing Construction...................................
S826
Class I, Division 2 & Zone 2 Suitability
Cooler Operating Temeratures (T-Numbers)
Certified for IEC Zone 2.................................................... S826TB
Furnished with terminal block crimp terminals and
dedicated voltage ballasts (no MT, DT, or TT)
Fused to protect ballast and capacitors against
abnormal line conditions
(Not available with /MT ballast)
(Not suitable for marine applications)................................ S658*
Quick-Clip - Holds weight of housing when closed.
No need to support luminaire while screwing the
housing to the cover..........................................................
S890
Quartz auxilliary lighting comes to full brightness
immediately and remains lit until the HID lamp attains
6070% of full illumination. For non-hazardous locations
only.....................................................................................
QTZ
Ballast-Gard starter cutout switch prevents starter
pulsing when lamp is cycling or inoperative; prolongs
ballast and ignitor life. Available for use with 200400W
HPS only............................................................................
BG
Factory assembled with H.I.D. lamps installed for
additional labor savings.....................................................
FA
Top hat with stainless steel threaded insert to attach
ballast housing...................................................................
S806
Note:

(Quartz lamp not included use 100W single ended lamp Q100DC,
Q100CL/DC, or 100Q/CL/DC). Consult factory for top-hat limitations.

Electrical Ratings:
120 to 600 volts and multi-tap
200, 250, 400W HPS and MH

Accessories:
See pages 977978 for complete listing.
Alzak is a registered trademark of ALCOA.
*When ordering fuses for luminaires, option S658, you must specify the operating voltage.
S658 cannot be ordered with /MT in the catalog number.
Not for use in Canada.
Suffix S826 and S826TB cannot be used with GRD4 Reflector/Lens.

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

951

3L

Cast copper-free aluminum construction (less than 0.4 of 1%


copper) and epoxy powder finish provide excellent resistance to
corrosion
Six mounting arrangements to suit any lighting layout pendant, ceiling,
wall bracket, angle stanchion, straight stanchion and quad-mount
Wide range of light sources and wattages to meet specifiers'
needs: 200, 250, 400 watt high pressure sodium (HPS); 250 and
400 watt metal halide (MH) and pulse start metal halide
Hinged ballast housing for ease of installation and maintenance
Wide choice of photometric distributions. Glass globes, glass
refractors, and reflector/lens are available
All luminaires designed to perform in a 40C ambient temperature.
Selected luminaires are suitable for ambient temperatures up to 65C
Superior gasketing seals between the mounting module, housing,
and optical assembly for optimum performance in wet and
corrosive environments
Hubs with integral conduit stop and bushing to help prevent
damage to field wiring during installation
Low ambient capability to (40C)
Dome and 30 angle reflectors made of bright white Krydon
material and etched Alzak high bay reflectors provide superior
reflectivity
Grounding wire for safety
High power factor ballasts (Min. P. F. 90%) are available in a
variety of voltages to meet local area requirements
Mogul base lamp socket

3L

952-953.qxp

6/13/2011

10:17 AM

Page 952

Cl. I, Div. 2, Groups A, B, C, D


Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

3L VMV High Wattage Series


200-400W High Pressure Sodium
For Medium and High Mounting Heights
Champ H.I.D. Luminaires

Cl. II, Groups E, F, G; Cl. III &


Simultaneous Presence
(with Glass Refractor)
Marine (with Globe or Glass
Refractor) & Wet Locations
3, 3R, 4, 4X; IP56 to IP66

To complete the catalog #, include information in notes 1 and 2 below. For guards and other optics see VMV High Wattage Series - Ordering
By Components page.
BASIC CATALOG NUMBER
Mounting
Style

Hub
Size

Lamp
Watts

With G303 Globe


and P33 Guard

With GR305 Glass


Refractor *

With GRD4
Reflector/Lens

Pendant Mount
(Rigid or Flexible)

/4
1
3
/4
1
3
/4
1

200

VMVS2A200GP
VMVS3A200GP
VMVS2A250GP
VMVS3A250GP
VMVS2A400GP
VMVS3A400GP

VMVS2A200GR305
VMVS3A200GR305
VMVS2A250GR305
VMVS3A250GR305
VMVS2A400GR305
VMVS3A400GR305

VMVS2A200GRD4
VMVS3A200GRD4
VMVS2A250GRD4
VMVS3A250GRD4
VMVS2A400GRD4
VMVS3A400GRD4

/4
1
/4
1
3
/4
1

200

250

VMVS2C200GP
VMVS3C200GP
VMVS2C250GP
VMVS3C250GP
VMVS2C400GP
VMVS3C400GP

VMVS2C200GR305
VMVS3C200GR305
VMVS2C250GR305
VMVS3C250GR305
VMVS2C400GR305
VMVS3C400GR305

VMVS2C200GRD4
VMVS3C200GRD4
VMVS2C250GRD4
VMVS3C250GRD4
VMVS2C400GRD4
VMVS3C400GRD4

/4
1
/4
1
3
/4
1

200

250

VMVS2TW200GP
VMVS3TW200GP
VMVS2TW250GP
VMVS3TW250GP
VMVS2TW400GP
VMVS3TW400GP

VMVS2TW200GR305
VMVS3TW200GR305
VMVS2TW250GR305
VMVS3TW250GR305
VMVS2TW400GR305
VMVS3TW400GR305

Ceiling Mount
Thru-Feed

Wall Mount
Thru-Feed

250
400

400

400

3
3

/4
/4
3
/4

200
250
400

VMVS25Q200GP
VMVS25Q250GP
VMVS25Q400GP

VMVS25Q200GR305
VMVS25Q250GR305
VMVS25Q400GR305

VMVS25Q200GRD4
VMVS25Q250GRD4
VMVS25Q400GRD4

Stanchion Mount
25 Angle

11/2
11/2
11/2

200
250
400

VMVSJ200GP
VMVSJ250GP
VMVSJ400GP

VMVSJ200GR305
VMVSJ250GR305
VMVSJ400GR305

VMVSJ200GRD4
VMVSJ250GRD4
VMVSJ400GRD4

Stanchion Mount
Straight

11/2
11/2
11/2

200
250
400

VMVSP200GP
VMVSP250GP
VMVSP400GP

VMVSP200GR305
VMVSP250GR305
VMVSP400GR305

3L

Quad-Mount
Pendant, Adjustable
Thru-Feed, 25 Angle,
121/ 2 Angle

* For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. VMVS2A200GR302
For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. VMVS2A200GR303

1. Add voltage suffix to end of catalog number


Standard Voltage Ballasts 60Hz
NEC/UL
Voltage
Suffix

Multi Tap
/MT

120V
/120

CEC/CSA (cUL)
480V
/480

Tri Tap
/TT

120V
/120

220V 60Hz
/220

220V 50Hz
/220 50

Optional Voltage Ballasts - 50 or 60Hz


CEC/CSA (cUL) - CWI Isolated Ballasts
Voltage
Suffix

208V CWI
/208CWI

240V CWI
/240CWI

480V CWI
/480CWI

600V CWI
/600CWI

EXPORT
230V 50Hz
/230 50

240V 50Hz
/240 50

2. Options - Add the required option suffixes, see page 951, in alpha-numeric order.

952

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

VMV High Wattage Series 250400W Pulse Start Metal Halide

Cl. I, Div. 2, Groups A, B, C, D


Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)

For Medium and High Mounting Heights


Champ H.I.D. Luminaires

Cl. II, Groups E, F, G; Cl. III &


Simultaneous Presence
(with Glass Refractor)
Marine (with Globe or Glass
Refractor) & Wet Locations
3, 3R, 4, 4X; IP56 to IP66

3L

To complete the catalog #, include information in notes 1 and 2 below. For guards and other optics see VMV High Wattage Series - Ordering
By Components page.
BASIC CATALOG NUMBER
Mounting
Style

Hub
Size

Lamp
Watts

With G303 Globe


and P33 Guard

With GR305 Glass


Refractor *

Pendant
Mount
(Rigid or
Flexible)

3
/4
1
3
/4
1
3
/4
1

250

VMVM2A250GP
VMVM3A250GP
VMVM2A320GP
VMVM3A320GP
VMVM2A400GP
VMVM3A400GP

S828
S828
S828
S828
S828
S828

VMVM2A250GR305
VMVM3A250GR305
VMVM2A320GR305
VMVM3A320GR305
VMVM2A400GR305
VMVM3A400GR305

S828
S828
S828
S828
S828
S828

VMVM2A250GRD4
VMVM3A250GRD4
VMVM2A320GRD4
VMVM3A320GRD4
VMVM2A400GRD4
VMVM3A400GRD4

S828
S828
S828
S828
S828
S828

3
/4
1
3
/4
1
3
/4
1

250

VMVM2C250GP
VMVM3C250GP
VMVM2C320GP
VMVM3C320GP
VMVM2C400GP
VMVM3C400GP

S828
S828
S828
S828
S828
S828

VMVM2C250GR305
VMVM3C250GR305
VMVM2C320GR305
VMVM3C320GR305
VMVM2C400GR305
VMVM3C400GR305

S828
S828
S828
S828
S828
S828

VMVM2C250GRD4
VMVM3C250GRD4
VMVM2C320GRD4
VMVM3C320GRD4
VMVM2C400GRD4
VMVM3C400GRD4

S828
S828
S828
S828
S828
S828

3
/4
1
3
/4
1
3
/4
1

250

Ceiling Mount
Thru-Feed

Wall Mount
Thru-Feed

320
400**

320
400**

320
400**

VMVM2TW250GP
VMVM3TW250GP
VMVM2TW320GP
VMVM3TW320GP
VMVM2TW400GP
VMVM3TW400GP

S828
S828
S828
S828
S828
S828

With GRD4
Reflector/Lens

VMVM2TW250GR305
VMVM3TW250GR305
VMVM2TW320GR305
VMVM3TW320GR305
VMVM2TW400GR305
VMVM3TW400GR305

S828
S828
S828
S828
S828
S828

/4
/4
/4

250
320
400**

VMVM25Q250GP S828
VMVM25Q320GP S828
VMVM25Q400GP S828

VMVM25Q250GR305 S828
VMVM25Q320GR305 S828
VMVM25Q400GR305 S828

VMVM25Q250GRD4 S828
VMVM25Q320GRD4 S828
VMVM25Q400GRD4 S828

Stanchion
Mount
25 Angle

11/2
11/2
11/2

250
320
400**

VMVMJ250GP S828
VMVMJ320GP S828
VMVMJ400GP S828

VMVMJ250GR305 S828
VMVMJ320GR305 S828
VMVMJ400GR305 S828

VMVMJ250GRD4 S828
VMVMJ320GRD4 S828
VMVMJ400GRD4 S828

Stanchion
Mount
Straight

11/2
11/2
11/2

250
320
400**

VMVMP250GP S828
VMVMP320GP S828
VMVMP400GP S828

VMVMP250GR305 S828
VMVMP320GR305 S828
VMVMP400GR305 S828

3
3

3L

Quad-Mount
Pendant,
Adjustable
Thru-Feed,
25 Angle,
121/ 2 Angle

* For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. VMVM2A250GR302-S828
For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. VMVM2A250GR303-S828
** To be used with ED28 (bulb shaped lamp).

1. Add voltage suffix to end of catalog number


Standard Voltage Ballasts 60Hz
NEC/UL
Voltage
Suffix

Multi Tap
/MT

120V
/120

Lamp Selection Table:


CEC/CSA (cUL)

480V
/480

Tri Tap
/TT

230V 50Hz
/230 50

240V 50Hz
/240 50

Fixture

Lamp Type

Bulb

120V
/120

Venture

Phillips

Sylvania

MP 320W/BU/ED28/UVS/PS/EM/950 MS320/U/PS

MS320/PS/BU-HOR

MP 320W/BU/ED28/UVS/PS/740

MS320/C/BU/PS

MP 320W/C/BU/ED28/EVS/PS/737

Optional Voltage Ballasts - 50 or 60Hz


EXPORT
Voltage
Suffix

220V 60Hz
/220

220V 50Hz
/220 50

VMVM320GP

320W PS MH

ED28, BT28

2. Options - Add the required option suffixes, see page 0000,


in alpha-numeric order.
VMVM400GP

www.crouse-hinds.com

400W PS MH

US: 1-866-764-5454

ED28, BT28

MP 400W/BU/ED28/UVS/PS/EM/950 N/A

CAN: 1-800-265-0502

Copyright 2012 Cooper Crouse-Hinds

M400/PS/U/BT28

953

954-955.qxp

6/13/2011

3L

10:18 AM

Page 954

VMV High Wattage Series


250-400W Metal Halide

Cl. I, Div. 2, Groups A, B, C, D


Restricted Breathing Cl. I,
Div. 2 & Zone 2 (Suffix S826)
Certified for IEC Zone 2
For Medium and High Mounting Heights (Suffix S826TB)

Champ H.I.D. Luminaires

Cl. II, Groups E, F, G; Cl. III &


Simultaneous Presence
(with Glass Refractor)
Marine (with Globe or Glass
Refractor) & Wet Locations
3, 3R, 4, 4X; IP56 to IP66

To complete the catalog #, include information in notes 1 and 2 below. For guards and other optics see VMV High Wattage Series - Ordering
By Components page.
BASIC CATALOG NUMBER
Mounting
Hub
Lamp
With G303 Globe
With GR305 Glass
With GRD4
Style
Size
Watts
and P33 Guard
Refractor *
Reflector/Lens
Pendant Mount
(Rigid or Flexible)

Ceiling Mount
Thru-Feed

/4
1
/4
1

250

400

/4
1
3
/4
1

250

/4
1
3
/4
1

250

Wall Mount
Thru-Feed

400

400

VMVM2A250GP
VMVM3A250GP
N/A
N/A

VMVM2A250GR305
VMVM3A250GR305
VMVM2A400GR305
VMVM3A400GR305

VMVM2A250GRD4
VMVM3A250GRD4
VMVM2A400GRD4
VMVM3A400GRD4

VMVM2C250GP
VMVM3C250GP
N/A
N/A

VMVM2C250GR305
VMVM3C250GR305
VMVM2C400GR305
VMVM3C400GR305

VMVM2C250GRD4
VMVM3C250GRD4
VMVM2C400GRD4
VMVM3C400GRD4

VMVM2TW250GP
VMVM3TW250GP
N/A
N/A

VMVM2TW250GR305
VMVM3TW250GR305
VMVM2TW400GR305
VMVM3TW400GR305

Quad-Mount
Pendant, Adjustable
Thru-Feed, 25
Angle, 121/2 Angle

/4
/4

250
400

VMVM25Q250GP
N/A

VMVM25Q250GR305
VMVM25Q400GR305

VMVM25Q250GRD4
VMVM25Q400GRD4

Stanchion Mount
25 Angle

11/2

250

VMVMJ250GP

VMVMJ250GR305

VMVMJ250GRD4

11/2

400

N/A

VMVMJ400GR305

VMVMJ400GRD4

11/2
11/2

250
400

VMVMP250GP
N/A

VMVMP250GR305
VMVMP400GR305

3L

Stanchion Mount
Straight

* For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. VMVM2A250GR302
For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. VMVM2A250GR303
1. Add voltage suffix to end of catalog number
Standard Voltage Ballasts 60Hz
NEC/UL
Voltage
Suffix

Multi Tap
/MT

120V
/120

CEC/CSA (cUL)
480V
/480

Tri Tap
/TT

120V
/120

220V 60Hz
/220

220V 50Hz
/220 50

Optional Voltage Ballasts - 50 or 60Hz


CEC/CSA (cUL) - CWI Isolated Ballasts
Voltage
Suffix

208V CWI
/208CWI

240V CWI
/240CWI

600V CWI
/600CWI

EXPORT
230V 50Hz
/230 50

240V 50Hz
/240 50

2. Options - Add the required option suffixes, see page 951, in alpha-numeric order.

954

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

954-955.qxp

6/13/2011

10:18 AM

Page 955

3L

VMV High Wattage Series


Ordering by Components

VMV High Wattage Luminaires are available in components.


A complete luminaire consists of:
I.
II.
III.

Champ Cover (Mounting Module)


VMV Ballast Housing Include voltage and required option(s)
Optical & Guard Components Globe, Reflector, Refractor, Guard

I. Champ Cover (Mounting Module):


Type
Pendant

Conduit

Cat. #

/4"
1"

APM2
APM3

Ceiling

/4"
1"

CM2
CM3

Wall

/4"
1"

TWM2
TWM3

Stanchion 25 Degree Angle

11/2"

JM5

Stanchion Straight

11/2"

PM5

Quad-Mount

/4"

QM25

II. Ballast Housings:


Complete catalog number must have the voltage suffix (MT shown) and any options suffixes.
Lamp Type
High Pressure Sodium

Metal Halide

Lamp Watts

Cat. #

200
250
400
250
400

VMVS200/MT
VMVS250/MT
VMVS400/MT
VMVM250/MT
VMVM400/MT

III. Globe, Reflectors, Refractors, Guards:


Cat. #

Globe

G303

Globe Guard

P33

Reflector Dome

RD739

Reflector Angle

RA739

Refractor Type 2

GR302

Refractor Type 3

GR303

Refractor Type 5

GR305

Refractor Guard

P23

High Bay Reflector/Lens

GRD4

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

3L

Type

Copyright 2011 Cooper Crouse-Hinds

955

956-957.qxp

3L

5/30/2011

9:52 AM

Page 956

VMV High Wattage Series

Family Tree

3L

Champ H.I.D. Luminaires

956

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

VMV High Wattage Series

Temperature Performance Data

3L

Champ H.I.D. Luminaires

High Pressure Sodium


200

40
55
65

325 C 350 C
325 C 350 C
325 C 350 C

250

40
55
65

400

40
55

T2
T2
T2

T3
T3
T3

T4
T4

T3C

T1/T3C

T3C

75
75
85

350 C 350 C 325 C


350 C 350 C 350 C
350 C 350 C

T3
T3
T3

T4
T4

T3C

T1/T3C

T3C

75
85

350 C 350 C
350 C 350 C

T3
T3

T4
T4

T3C

T1/T3C

T3C

85
90

T1
T1

Metal Halide
40
55

350 C 325 C 350 C


350 C 350 C 350 C

T3
T3

T4
T4

T3B

350 C/T3B

T3B

85
90

250

40
55

350 C 325 C 350 C


350 C 350 C 350 C

T3
T3

T4
T4

T3B

350 C/T3B

T3B

85
90

400

40
55

T4

T3B

350 C/T3B

T3B

85

T3
T3

T4
T4

T3B

350 C/T3B

T3B

85
90

325 C
350 C

T1
T1

3L

200

Pulse Start Metal Halide (S828)


250

40
55

350 C 350 C 325 C


350 C 350 C 350 C

320

40

T1

325 C

T2A

T3

90

400

40

T1

T1

T1

T3

T4

90

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2012 Cooper Crouse-Hinds

957

958-959.qxp

5/30/2011

9:53 AM

Page 958

VMV High Wattage Series

3L

Dimensions & Weights

Champ H.I.D. Luminaires


Dimensions
In Inches:

Pendant Mount

Ceiling Mount

Wall Mount

25 Angle
Stanchion Mount

Luminaire with
Glass Refractor, Guard

3L

Quad-Mount

Luminaire with Etched Alzak


Reflector/Lens

Straight Stanchion Mount

Luminaire with Globe,


Guard, Reflectors

Net Luminaire Weights (lbs.):


Luminaire
Series
VMVS
VMVM

Lamp
Watts
200
250
400
250
400

Luminaire with:
Globe,
Reflector/
Guard (lbs.) Lens
291/2
291/2
381/2
321/2

30
30
39
33
34

Type
Lbs.
Type
Add for mounting modules:
Quad-Mount
Pendant
11/4
Angle Stanchion
Ceiling
23/4
Straight Stanchion
Wall
41/2
Add for reflectors:
30 Angle
Dome
11/2
High Bay
13/4
Deduct: 11/2 lb. for luminaire without P33 Guard
958

www.crouse-hinds.com

US: 1-866-764-5454

Glass
Refractor (lbs.)
321/2
321/2
411/2
353/4
351/2
Lbs.
31/2
31/2
41/2
11/2

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

958-959.qxp

5/30/2011

9:53 AM

Page 959

3L

Photometric Data

VMV High Wattage Series


Champ H.I.D. Luminaires

Lamp: 250W/E18 high pressure sodium (HPS)


Total bare lamp lumens: 27500
Note: All data provided is for high pressure sodium luminaires with 250W/E18 clear lamps. Use conversion factors (multipliers) shown below for other clear lamp types and wattages.
Consult Cooper Crouse-Hinds for additional photometric data on any Champ series luminaire.

Luminaire with Globe and Dome Reflector


Multipliers (for use with
candela curve only).
ConLuminaire Lamp version
Series
Watts Factor
VMVS

200
400

0.80
1.82

Luminaire spacing ratio: 2.0

Coefficient of Utilization
Effective Floor Cavity Reflectance 20%
% Reflectance
Eff. Ceil.
Wall

80

50
30
10

.750
.711
.677

.640
.582
.532

.550
.482
.429

.476
.402
.346

.416
.341
.285

70

50
30
10

.732
.696
.664

.625
.570
.526

.538
.474
.424

.465
.397
.343

.405
.335
.282

50

50
30
10

.695
.666
.641

.594
.549
.509

.513
.458
.414

.443
.384
.336

.388
.326
.279

30

50
30
10

.663
.640
.618

.567
.530
.496

.490
.443
.405

.423
.372
.330

.371
.316
.273

10

50
30
10

.635
.615
.597

.542
.510
.483

.469
.429
.395

.405
.360
.323

.355
.307
.268

.580

.464

.377

.251

10

80

50
30
10

.369
.295
.243

.327
.255
.208

.290
.222
.173

.263
.196
.150

.229
.163
.121

70

50
30
10

.360
.291
.239

.320
.251
.204

.285
.219
.172

.258
.193
.149

.224
.163
.121

50

50
30
10

.344
.283
.236

.306
.243
.200

.272
.213
.170

.247
.189
.147

.216
.159
.119

30

50
30
10

.330
.275
.233

.292
.238
.196

.262
.207
.167

.238
.183
.145

.207
.154
.116

10

50
30
10

.317
.267
.229

.282
.233
.194

.251
.202
.165

.229
.179
.142

.200
.150
.114

.212

.178

.149

.128

.101

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

3L

.305

Room Cavity Ratio


6
7
8

% Reflectance
Eff. Ceil.
Wall

www.crouse-hinds.com

Room Cavity Ratio


1
2
3

959

1000-1001.qxp

5/30/2011

10:13 AM

Page 1001

EVLP Low Profile HazardGard


(H.I.D.) Luminaires

Cl. I, Div. 1, Groups B


(GB suffix), C, D
Cl. I, Zone 1, Groups IIB + H2
(with suffix GB), IIB, IIA
Cl. II, Div. 1, Groups E, F, G;
Class III

Medium and Mogul Base

Marine & Wet


Locations
3, 3R, 4, 4X; IP66

4L

Applications:

Standard Materials:

Cooper Crouse-Hinds Low Profile


HazardGard luminaires are used in:
Areas where flammable or explosive
vapors or gases are present
Hazardous areas, both indoors and
outdoors, where long life and low
maintenance costs are desired
Petroleum refineries, chemical,
petrochemical and pharmaceutical
plants, oil terminals, gas plants and other
heavy process industry facilities
Waste treatment facilities
Drilling platforms and other coastal and
offshore hazardous areas

Mounting modules, cover, ballast


housing, globe holder copper-free
aluminum
Globe heat and impact resistant glass
Exterior hardware stainless steel
Reflectors (dome & angle) Krydon
fiberglass-reinforced polyester

Copper-free aluminum Corro-free


powdered epoxy
Krydon white
Stainless steel guard

Features and Benefits:

Ratings (Electrical/Size):
Certifications and
Compliances:
NEC and CEC:
Class I, Division 1, Groups B
(with suffix GB), C, D All Wattages
Class I, Zone 1, Groups IIB + H2
(with suffix GB), IIB, IIA All Wattages
Class II and Class III
UL Standards:
844, Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations
CSA Standards
C22.2 No. 137

Sources/Wattage:
Medium Base 70150W HPS, 70175W
MH
Mogul Base 70150W HPS, 70250W
MH
Voltages:
Medium & Mogul H.I.D.
120V 60Hz
Multi-tap (120, 208, 240, 277V 60Hz)
Tri-tap (120, 277, 347V 60Hz)
480V 60Hz
Other voltages consult Cooper
Crouse-Hinds
Conduit Entries:
3/4", 1" NPT pendant, wall bracket,
ceiling
11/4" NPT stanchion

Options:
Description
Suffix
Group B suitability ........................................................................................... GB
Ballast-Gard (HPS only) ................................................................................. BG
Instant restrike (Mogul Base only) ...................................................................
IR
70150W LX HPS
Cannot use with BG Option
Fused (not suitable for marine applications).................................................... S658*
Quartz auxiliary lighting
(Mogul Base only) ............................................................................................ QTZ
Cannot use with IR option
Uses 100W single ended double contract lamp
Quartz lamp not included
Factory assembled with lamps ........................................................................
FA

4L

Small, compact size is perfect where low


mounting restrictions are a concern.
Two start Acme threaded construction
allows for easier assembly, installation
and maintenance.
Lightweight copper-free aluminum
housing with powdered epoxy finish for
superior corrosion resistance.
All exterior hardware is corrosionresistant stainless steel.
Four mounting arrangements: pendant,
ceiling, wall bracket and stanchion suit
any lighting layout.
Wide range of light sources and
wattages to meet specific lighting needs.
Marine and NEMA 4X construction
suitable for outdoor, hose down, marine
and corrosive environments.
Integral ballast for lowest installed cost.
High power factor (90%+) ballasts allows
more fixtures per circuit.
Uses same mounting modules as the
standard HazardGard for easy
retrofitting when the Lo-Pro is the
preferred choice.
Internally fluted glass globe reduces
glare and distributes light evenly ideal
for adverse enviroments typical of
industrial facilities.
Krydon construction dome and angle
reflectors wont rust, corrode, dent,
chip or peel
Now available in components luminaire
body, mounting module, guard,
reflectors allowing for easy stocking for
Quick Ship requirements.

Standard Finishes:

*When ordering fuses for luminaires, option S658, you must specify the operating voltage.
S658 cannot be ordered with /MT in the catalog number.

Accessories:
Description

Cat. #

Dome reflector
Angle reflector

RD739
RA739

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

1001

1002-1003.qxp

4L

5/30/2011

10:13 AM

Page 1002

EVLP Low Profile


HazardGard

Marine & Wet Locations


3, 3R, 4, 4X; IP66

Cl. I, Div. 1, Groups B


(GB suffix), C, D
Cl. I, Zone 1, Groups IIB + H2
(with GB suffix), IIB, IIA
Cl. II, Div. 1, Groups E, F, G;
Class III

Medium Base
Ordering Information:

Pendant
Hub
With Guard
Watt Size (In.) Cat. #

Wall Bracket

Ceiling

Stanchion

Luminaire Body
Less Mounting
Module & Guard

With Guard
Cat. #

With Guard
Cat. #

With Guard
Cat. #

Cat. #

High Pressure Sodium


/4
1
11/4

EVLPA142071
EVLPA143071

EVLPBX142071
EVLPBX143071

EVLPCX142071
EVLPCX143071

/4
100W 1
11/4

EVLPA142101
EVLPA143101

EVLPBX142101
EVLPBX143101

EVLPCX142101
EVLPCX143101

/4
150W 1
11/4

EVLPA142151
EVLPA143151

EVLPBX142151
EVLPBX143151

EVLPCX142150
EVLPCX143151

70W
Pendant Mount

EVLP14070
EVLPJ144071
EVLP14100
EVLPJ144101
EVLP14151
EVLPJ144151

Pulse Start Metal Halide


3
/4
150W 1
11/4

EVLPA192151 S828 EVLPBX192151 S828 EVLPCX192151 S828


EVLPA193151 S828 EVLPBX193151 S828 EVLPCX193151 S828

/4
175W 1
11/4

EVLPA192171 S828 EVLPBX192171 S828 EVLPCX192171 S828


EVLPA193171 S828 EVLPBX193171 S828 EVLPCX193171 S828

Wall Bracket
Mount

EVLP19150 S828
EVLPJ194151 S828
EVLP19175 S828
EVLPJ194171 S828

Metal Halide
3
/4
1
11/4

EVLPA192071
EVLPA193071

/4
100W 1
11/4

EVLPA192101
EVLPA193101

/4
175W 1
11/4

EVLPA192171
EVLPA193171

70W

4L

EVLPBX192071
EVLPBX193071

EVLPCX192071
EVLPCX193071

EVLP19070
EVLPJ194071

EVLPBX192101
EVLPBX193101

EVLPCX192101
EVLPCX193101

EVLP19100
EVLPJ194101

EVLPBX192171
EVLPBX193171

EVLPCX192171
EVLPCX193171

EVLP19175
EVLPJ194171

Ceiling Mount

Complete Catalog Number as follows:


Standard Voltage Ballasts 60Hz
1.

NEC/UL
Voltage
Suffix

Multi Tap
/MT

120V
/120

CEC/CSA (cUL)
480V
/480

Tri Tap
/TT

120V
/120

Optional Voltage Ballasts 50 or 60Hz


*CEC/CSA (cUL) CWI Isolated Ballasts
Voltage
Suffix

208V CWI
/208CWI

240V CWI
/240CWI

EXPORT

600V CWI
/600CWI

220V 60Hz
/220

220V 50Hz
/220 50

2. 150W HPS Luminaires only

Stanchion Mount

55V lamps add suffix "LX"


100V lamps add suffix "CE"

Ceiling and bracket mounts have 4 hubs: 3 are plugged.


*CWI Isolated Ballasts are only available for high pressure sodium and 175W metal halide (non pulse start) luminaires.

1002

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

230V 50Hz
/230 50

240V 50Hz
/240 50

1002-1003.qxp

5/30/2011

10:13 AM

Page 1003

EVLP Low Profile


HazardGard

Cl. I, Div. 1, Groups B (GB suffix), C, D


Cl. I, Zone 1, Groups IIB + H2
(with GB suffix), IIB, IIA
Cl. II, Div. 1, Groups E, F, G; Class III

Mogul Base

4L

Marine & Wet Locations


3, 3R, 4, 4X; IP66

Ordering Information:

Pendant
With
Guard
Hub
Watt Size(In.) Cat. #

Wall Bracket
With Guard
Cat. #

Ceiling
With Guard
Cat. #

Stanchion
With Guard
Cat. #

Luminaire Body
Less Mounting
Module & Guard
Cat. #

High Pressure Sodium


3
/4
1
11/4

EVLPA042071
EVLPA043071

EVLPBX042071
EVLPBX043071

EVLPCX042071
EVLPCX043071

/4
100W 1
11/4

EVLPA042101
EVLPA043101

EVLPBX042101
EVLPBX043101

EVLPCX042101
EVLPCX043101

/4
150W 1
11/4

EVLPA042151
EVLPA043151

EVLPBX042151
EVLPBX043151

EVLPCX042151
EVLPCX043151

70W

EVLPJ044071

Pendant Mount

EVLP04070

EVLP04100
EVLPJ044101

EVLP04150
EVLPJ044151

Pulse Start Metal Halide


3
/4
150W 1
11/4

EVLPA092151S828 EVLPBX092151S828 EVLPCX092151S828


EVLPA093151S828 EVLPBX093151S828 EVLPCX093151S828

/4
175W 1
11/4

EVLPA092171S828 EVLPBX092171S828 EVLPCX092171S828


EVLPA093171S828 EVLPBX093171S828 EVLPCX093171S828

/4
200W 1
11/4

EVLPA092201S828 EVLPBX092201S828 EVLPCX092201S828


EVLPA093201S828 EVLPBX093201S828 EVLPCX093201S828

/4
250W 1
11/4

EVLPA092251S828 EVLPBX092251S828 EVLPCX092251S828


EVLPA093251S828 EVLPBX093251S828 EVLPCX093251S828

EVLPJ094151S828

EVLP09170S828
EVLPJ094171S828

Wall Bracket
Mount

EVLP09150S828

EVLP09201S828
EVLPJ094201S828

EVLP09250S828
EVLPJ094251S828

Metal Halide
3
/4
1
11/4

EVLPA092071
EVLPA093071

/4
100W 1
11/4

EVLPA092101
EVLPA093101

EVLPBX092101
EVLPBX093101

EVLPCX092101
EVLPCX093101

/4
175W 1
11/4

EVLPA092171
EVLPA093171

EVLPBX092171
EVLPBX093171

EVLPCX092171
EVLPCX093171

/4
250W 1
11/4

EVLPA092251
EVLPA093251

70W

Ceiling Mount

EVLPCX092071
EVLPCX093071

EVLP09070
EVLPJ094071
EVLP09100
EVLPJ094101

4L

EVLPBX092071
EVLPBX093071

EVLP09170
EVLPJ094171

EVLPBX092251
EVLPBX093251

EVLPCX092251
EVLPCX093251

EVLP09250
EVLPJ094251

Complete Catalog Number as follows:


Standard Voltage Ballasts 60Hz
1.
Voltage
Multi Tap
Suffix
/MT

NEC/UL
120V
/120

CEC/CSA (cUL)
480V
/480

Tri Tap
/TT

Optional Voltage Ballasts 50 or 60Hz


*CEC/CSA (cUL) CWI Isolated Ballasts
Voltage
Suffix

Stanchion Mount

208V CWI
/208CWI

240V CWI
/240CWI

600V CWI
/600CWI

120V
/120

EXPORT
220V 60Hz
/220

220V 50Hz
/220 50

230V 50Hz
/230 50

240V 50Hz
/240 50

2. 150W HPS Luminaires only


55V lamps add suffix "LX"
100V lamps add suffix "CE"
Example: EVLPA043151/MT-LX

Ceiling and wall bracket mounts have 4 hubs: 3 are plugged.


*CWI Isolated Ballasts are only available for high pressure sodium and 175W250W metal halide (non pulse start) luminaires.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

1003

1004-1005.qxp

5/30/2011

10:14 AM

Page 1004

EVLP Low Profile


HazardGard

4L

Ordering by Components
EVLP Luminaires are available in components.
A

complete luminaire consists of:


Mounting Module
Luminaire Body
Guard, Dome Reflector or Angle Reflector

Mounting Modules:
Type
Pendant

Conduit

Cat. #

/4"
1"

EVMP2
EVMP3

/4"
1"

EV22
EV33

Ceiling & Wall Box


Wall Bracket Arm

Use EV22 or EV33 box with EV87

EV87

Stanchion

11/4"

EVMJ4

Guards
Medium
Mogul

EV511
EV512

Reflectors
Dome
Angle

RD739
RA739
Pendant

Ceiling

Stanchion

Ceiling

Wall Bracket

EVMP2
EVMP3

EV22
EV33

EVMJ4

EV22
EV33

EV87 & EV22 or EV33

4L

Luminaire Body
EVLP0 Series H.I.D. Mogul Lamp
EVLP1 Series H.I.D. Medium Lamp

1004

Guards

Dome Reflector

Angle Reflector

EV511
EV512

RD739

RA739

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

1004-1005.qxp

5/30/2011

10:14 AM

Page 1005

4L

Temperature Performance Data

EVLP Low Profile


HazardGard

Medium Base Lamp Luminaires:

Maximum Ambient

Watts

Class I, Group B
(w/GB suffix)
Groups C, D
40C
55C

65C

Class II, Groups E, F, G


Class III
Simultaneous
Presence
40C

High Pressure Sodium

70W
100W
150W

T5
T4A
T4

T4A
T4A
T3C

T4A
T4

T4A
T4

90C
90C
90C

Metal Halide
(including pulse start)

70W
100W
150W
175W

T5
T3C
T3C
T3C

T4A
T3C
T3B
T3B

T4A

T4

85C
90C
90C
90C

Supply Wire C

Mogul Base Lamp Luminaires:


Class II, Groups E, F, G
Class III
Simultaneous
Presence

Class I, Group B
(w/GB suffix)
Groups C, D
Maximum Ambient

Watts

40C

55C

65C

40C

Supply Wire C

High Pressure Sodium

70W
100W
150W

T6
T5
T4A

T5
T4A
T4

T5

T5
T4A
T4

90C
90C
90C

Metal Halide
(including pulse start)

70W
100W
150W
175W
200W
250W

T6
T5
T4
T4
T3C
T3C

T5
T4A
T3C
T3C

T5
T4A

T5
T4A
T3C
T3C

85C
90C
90C
90C
90C
90C

4L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

1005

1006-1007.qxp

5/30/2011

4L

10:16 AM

Page 1006

EVLP Low Profile


HazardGard
Dimensions and Weights

Dimensions
In Inches:

4L

Medium Base
Mogul Base

13.92
15.69

12.73
14.69

16.50
18.25

16.71
18.46

20.59
22.34

19.36
21.30

Weights
(lbs.):
Luminaire w/guard
Source
High Pressure Sodium

Watts

Medium

Mogul

70
100
150

34
36
36.5

36.5
38.5
39

70
100
150
175
200
250

33.5
34.5
36
36

36
37
38.5
38.5
40.5
40.5

Metal Halide

Medium

Mogul

Add Mounting Modules:


Pendant
Ceiling
Bracket
Stanchion

1
2
4.5
2.5

1
2
4.5
2.5

Add For Reflectors:


RA739
RD739
Deduct for Wire Guard

1
1
0.5

1
1
0.5

1006

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

1006-1007.qxp

5/30/2011

10:16 AM

Page 1007

Photometric Data

EVLP Low Profile


HazardGard

4L

Medium Base
Medium Base
Luminaire with Globe and Guard
EVLPA143151 Lamp: 150W/B17 High Pressure Sodium (HPS)

Medium Base
Luminaire with Globe and Dome Reflector (Less Guard)
EVLPA143150RD Lamp: 150W/B17 High Pressure Sodium (HPS)

4L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

1007

1008-1009.qxp

5/30/2011

4L

10:16 AM

Page 1008

Photometric Data

EVLP Low Profile


HazardGard
Medium and Mogul Base

Medium Base
Luminaire with Globe and 30 Angle Reflector (Less Guard)
EVLPA143150RA Lamp: 150W/B17 High Pressure Sodium (HPS)

Mogul Base
Luminaire with Globe and Guard
4L

EVLPA043151 Lamp: 150W/E23-1/2 High Pressure Sodium (HPS)

1008

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

1008-1009.qxp

5/30/2011

10:16 AM

Page 1009

EVLP Low Profile


HazardGard

4L

Photometric Data

Mogul Base
Mogul Base
Luminaire with Globe and Dome Reflector (Less Guard)
EVLPA043150RD Lamp: 150W/E23-1/2 High Pressure Sodium (HPS)

Mogul Base
Luminaire with Globe and 30 Angle Reflector (Less Guard)
EVLPA043150RA Lamp: 150W/E23-1/2 High Pressure Sodium (HPS)

4L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

1009

1010-1011.qxp

5/30/2011

4L

10:17 AM

Page 1010

Photometric Data

EVLP Low Profile


HazardGard
Mogul Base

Mogul Base
Luminaire with Globe and Guard
EVLPA093171 Lamp: 175W/ED28 Metal Halide (MH)

Mogul Base
Luminaire with Globe and Dome Reflector (Less Guard)
4L

EVLPA093170RD Lamp: 175W/ED28 Metal Halide (MH)

1010

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

1010-1011.qxp

5/30/2011

10:17 AM

Page 1011

4L

Photometric Data

EVLP Low Profile


HazardGard
Mogul Base
Mogul Base

Luminaire with Globe and 30 Angle Reflector (Less Guard)


EVLPA093170RA Lamp: 175W/ED28 Metal Halide (MH)

4L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

1011

984-985.qxp

5/30/2011

10:03 AM

Page 985

EVLS HazardGard
Compact & Rugged, Class I, Zone 1,
Div. 1 Explosionproof Luminaire

Cl. I, Div. 1, Group B


(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III & Simultaneous Presence

Introducing a compact, affordable,


explosionproof luminaire that has the best
overall temperature performance ratings in
its class!
Cooper Crouse-Hinds EVLS HazardGard
is perfect as a general area lighting
workhorse where space constraints exist.
EVLS HazardGard is easy to install, 175
watts and less, has select options that are
just right for your budget AND its
Class I, Division 1, Group B with GB option!

Standard Materials:

Applications:

Ratings (Electrical Size):

Cooper Crouse-Hinds EVLS HazardGard


Lighting Fixures are used for general
lighting and task lighting in:
Areas where flammable or explosive
vapors or gases are present
Confined spaces or heavy process
industry facilities
Petroleum refineries; chemical,
petrochemical and pharmaceutical
plants; oil terminals; gas plants
Waste treatment facilities
Drilling platforms and other coastal and
offshore hazardous areas

Features:

Certification &
Compliances:

4L

Bodies, mounting modules and cast


guards copper-free aluminum
Wire guard stainless steel
Globe heat- and impact-resistant glass
Gaskets silicone and neoprene

Standard Finishes:
Epoxy powder coat paint

Sources/Wattages:
HID Medium Base (initial offering)
HPS: 50, 70, 100, 150 watt
Metal Halide: 70, 100, 175 watt
Pulse Start Metal Halide: 150, 175 watt
Voltages:
Multi-tap (120, 208, 240, 277V/60 Hz)
480V/60 Hz
Tri-tap (120, 277, 347V/60 Hz)
220V/60 Hz
220/240V (or 230V)/50 Hz
Transformer Types:
HX-HPF Standard
CWA Standard on 175W
CWA Constant Wattage Autotransformer
CWI Constant Wattage Insulation
Transformer
Available for HPS and MH, for most
voltages and wattages (Additional
voltages available on request.)
Conduit Entries:
3/4" and 1" NPT pendant, ceiling and
wall mount
11/2" NPT stanchion

Two Start Acme Threads

4L

Compact and rugged - a Division 1


luminaire that fits in tight spaces
Smooth turning two start Acme threads
for mounting modules and globe
attachments save time and eliminate
installation damage
Quick-connect design facilitates easy
installation and saves money - install and
wire the mounting module, and then
screw in luminaire to make the electrical
connection
Best overall T-rating in the industry for a
medium-base HID lamp - use in elevated
ambient and illuminate the most volatile
areas of your facility - optimal safety in
your high-risk areas
Factory-sealed - wired and sealed with
no external sealing fittings required in
Groups B, C, and D
An adapter module is available for direct
connection to existing HazardGard
modules such as the EV22 ceiling mount

UL and cUL Listed


Wet locations (UL1598)
Marine locations (UL1598A)
Type 4X, IP66

Options:
Description
Instant Restrike (HPS)
Ballast-Gard (HPS)
Group B Suitability

Suffix
IR
BG
GB

Accessories:
Description
Dome Reflector
Angle Reflector
Guard

Suffix
RD725
RA725
EV502 or P515

UL (844) and cUL Listed (CSA C22.2


No. 137) for:
Class I, Division 1, Groups B (with suffix
GB), C, D
Class I, Zone 1, Group IIB + H2 (with
suffix GB)
Class II, Class III & Simultaneous
Presence
Wet locations (UL1598), Marine locations
(UL1598A), Type 4X, IP66

www.crouse-hinds.com

Quick Connect Design

Adapter Module Available

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

985

986-987.qxp

5/30/2011

10:04 AM

Page 986

4L EVLS HazardGard

Cl. I, Div. 1, Groups B


(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Compact & Rugged, Class I, Zone 1, Cl. II, Cl. III & Simultaneous Presence

UL and cUL Listed


Wet locations (UL1598),
Marine locations (UL1598A)
Type 4X, IP66

Div. 1 Explosionproof Luminaire


Mounting Modules:

New Mounting Modules

Existing For EVI, EVLP, EVM (must use EVSA adapter)


Conduit
Catalog Number

Type
Adapter
Pendant

"
1"

EVSA
EVMP2
EVMP3

Ceiling & Wall Box

"
1"

EV22
EV33

Wall Bracket Arm

Use EV22 or EV33 box with

EV87

Stanchion
Bulkhead

1"
1"

EVMJ4
EVJ2

Conduit
"
1"
25mm
32mm
"
1"
25mm
32mm
"
1"
25mm
32mm
1"
"
25mm

For EVLS Only


Catalog Number
EVSP2
EVSP3
EVSP25
EVSP32
EVSC2
EVSC3
EVSC25
EVSC32
EVSW2
EVSW3
EVSW25
EVSW32
EVSJ5
EVSB2
EVSB25

Family Tree:
Existing Mounting
Modules used on
EVI, EVLP, EVM
(must use EVSA adapter)
EVMP2
EVMP3

EV22
EV33

EVMJ4

EVJ2
EV22
EV33

EV87

EVSA ADAPTER
EVSJ5

4L

New Mounting
Modules for EVLS

EVSC2
EVSC3
EVSC25
EVSC32

EVSB2
EVSB25

EVSP2
EVSP3
EVSP25
EVSP32

EVSW2
EVSW3
EVSW25
EVSW32

EVLS (For example: EVLS9170)

RA725

RD725

EV502

986

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

P515

Copyright 2011 Cooper Crouse-Hinds

986-987.qxp

5/30/2011

10:04 AM

Page 987

EVLS HazardGard

UL and cUL Listed


4L
Wet locations (UL1598),
Marine locations (UL1598A)
Type 4X, IP66

Cl. I, Div. 1, Groups B


(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III & Simultaneous Presence

Compact & Rugged, Class I, Zone 1,


Div. 1 Explosionproof Luminaire
Ordering Reference Sheet:
EVLS

HazardGard
Low-Profile Luminaire
Class I, Div. 1/Class I, Zone 1
Class II, Groups F & G

10

/MT

-IR

A = Pendant
Mounting Type
BX = Wall
CX = Ceiling
BH = Bulkhead
J = Stanchion
M = Mounting Module Adapter
4 = High-Press. Sodium
9 = Metal Halide

Lamp Type

Conduit Entry (specify with mtg. modules)


2 = 3/4" NPT (Pendant, Ceiling, Bulkhead & Wall mounts only)
3 = 1" NPT (Pendant, Ceiling & Wall mounts only)
5 = 1-1/2" NPT (Stanchion only)
25 = 25 mm (Pendant, Ceiling, Bulkhead & Wall mounts only)
32 = 32 mm (Pendant, Ceiling & Wall mounts only)
Note: Omit for mounting module adapter
05 = 50W HPS
07 = 70W HPS, MH
10 = 100W HPS, MH
15 = 150 HPS, MH Pulse Start
17 = 175W MH, MH Pulse Start
0 = globe only, no guard
1 = stainless steel wire guard
2 = cast aluminum guard

Lamp Wattage
by lamp type

Guard
(optional)
Voltage and Frequency
HPS
70

100

150

70

100

150 PS

MT

TT

DT

120

175 PS

208
220
220 50

175

4L

50

MH

240

240 50

277

347

480

BG = Ballast Guard (lamp type S only)


CWI = SCE Ballast
GB = Group B suitability
IR = Instant Restrike (lamp type S only)
S828 = Pulse Start (175W & 150W MH only)

x
x

Options

Note: BG and IR options cannot be installed together.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

987

988-989.qxp

5/30/2011

10:05 AM

Page 988

4L EVLS HazardGard

Cl. I, Div. 1, Groups B


(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Compact & Rugged, Class I, Zone 1, Cl. II, Cl. III & Simultaneous Presence

UL and cUL Listed


Wet locations (UL1598),
Marine locations (UL1598A)
Type 4X, IP66

Div. 1 Explosionproof Luminaire


Temperature Performance Data:
Watts
Ambient Temp C
High Pressure Sodium

Class I,
Div. 1 & Zone 1

Class II
(Dust) and Class III

Supply Wire Temp C

T5
T4A
T4A
T5
T4A
T4A
T4A
T4
T4
T4A
T4

T5

T5

T3C

T3C

90
90
105
90
90
105
90
90
105
90
90

T4A

T4

90
90
105
90
90
105
90
90
90

40
55
65
40
55
65
40
55
65
40
55

50W

70W

100W

150W

Metal Halide (including Pulse Start [PS] as indicated)


40
55
65
40
55
65
40
40
40

70W

100W
150 PS
175W
175 PS

T5
T4A
T4A
T4A
T4A
T4
T3C
T3C
T3C

Net Luminaire Weights (lbs.):


Luminaire Series
High Pressure Sodium
EVLS4

Lamp Watts

Weight with Globe &


Wire Guard
18.5
21.5
22.5
24

70W
100W
150 PS
175W
175 PS

Add for cast guard:

20
20.5
23
23
23
1

Add for mounting modules:


Pendant
Ceiling
Stanchion
Bulkhead
Wall
Adapter

2
3.5
3
2.5
5.5
2

Add for reflectors:


Dome
Angle

1.5
2

4L

50W
70W
100W
150W

Metal Halide
EVLS9

988

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

988-989.qxp

5/30/2011

10:06 AM

Page 989

EVLS HazardGard
Compact & Rugged, Class I,
Zone 1, Div. 1 Explosionproof Luminaire

Cl. I, Div. 1, Groups B


(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2 (with
suffix GB)
Cl. II, Cl. III & Simultaneous Presence

UL and cUL Listed


4L
Wet locations (UL1598),
Marine locations (UL1598A)
Type 4X, IP66

Ordering Information High Pressure Sodium:

Wattage

Hub Size

No Guard

PENDANT
Wire Guard

Cast Guard

No Guard

BULKHEAD
Wire Guard

Cast Guard

/4"
1"
11/2"
25 mm
32 mm
3
/4"
1"
11/2"
25 mm
32 mm
3
/4"
1"
11/2"
25 mm
32 mm
3
/4"
1"
11/2"
25 mm
32 mm

EVLSA42050
EVLSA43050

EVLSA42051
EVLSA43051

EVLSA42052
EVLSA43052

EVLSBH42050

EVLSBH42051

EVLSBH42052

EVLSA425050
EVLSA432050
EVLSA42070
EVLSA43070

EVLSA425051
EVLSA432051
EVLSA42071
EVLSA43071

EVLSA425052
EVLSA432052
EVLSA42072
EVLSA43072

EVLSBH425050

EVLSBH425051

EVLSBH425052

EVLSBH42070

EVLSBH42071

EVLSBH42072

EVLSA425070
EVLSA432070
EVLSA42100
EVLSA43100

EVLSA425071
EVLSA432071
EVLSA42101
EVLSA43101

EVLSA425072
EVLSA432072
EVLSA42102
EVLSA43102

EVLSBH425070

EVLSBH425071

EVLSBH425072

EVLSBH42100

EVLSBH42101

EVLSBH42102

EVLSA425100
EVLSA432100
EVLSA42150
EVLSA43150

EVLSA425101
EVLSA432101
EVLSA42151
EVLSA43151

EVLSA425102
EVLSA432102
EVLSA42152
EVLSA43152

EVLSBH425100

EVLSBH425101

EVLSBH425102

EVLSBH42150

EVLSBH42151

EVLSBH42152

EVLSA425150
EVLSA432150

EVLSA425151
EVLSA432151

EVLSA425152
EVLSA432152

EVLSBH425150

EVLSBH425151

EVLSBH425152

50W

70W

100W

150W

Complete
Standard Voltage Ballasts
catalog
number
as follows: NEC/UL

CEC/CSA (cUL)

Export

Multi-tap

120V

480V

Suffix

/MT

/120

/480

/TT

/120

www.crouse-hinds.com

/208CWI

240V
CWI

480V
CWI

600V
CWI

220V
60 Hz

220V
50 Hz

240V
50 Hz

/240CWI

/480CWI

/600CWI

/220

/220 50

/240 50

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

4L

Voltage

Tri-Tap 120V 208V


CWI

989

4L EVLS HazardGard

Cl. I, Div. 1, Groups B


(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Compact & Rugged, Class I, Zone 1, Cl. II, Cl. III & Simultaneous Presence

UL and cUL Listed


Wet locations (UL1598),
Marine locations (UL1598A)
Type 4X, IP66

Div. 1 Explosionproof Luminaire

Ordering Information High Pressure Sodium (Cont'd):

Wattage

/4"
1"
11/2"
25 mm
32 mm
3
/4"
1"
11/2"
25 mm
32 mm
3
/4"
1"
11/2"
25 mm
32 mm
3
/4"
1"
11/2"
25 mm
32 mm
3

50W

70W

100W

4L

150W

WALL
Wire Guard

Cast Guard

No Guard

CEILING
Wire Guard

Cast Guard

EVLSBX42050
EVLSBX43050

EVLSBX42051
EVLSBX43051

EVLSBX42052
EVLSBX43052

EVLSCX42050
EVLSCX43050

EVLSCX42051
EVLSCX43051

EVLSCX42052
EVLSCX43052

EVLSBX425050
EVLSBX432050
EVLSBX42070
EVLSBX43070

EVLSBX425051
EVLSBX432051
EVLSBX42071
EVLSBX43071

EVLSBX425052
EVLSBX432052
EVLSBX42072
EVLSBX43072

EVLSCX425050
EVLSCX432050
EVLSCX42070
EVLSCX43070

EVLSCX425051
EVLSCX432051
EVLSCX42071
EVLSCX43071

EVLSCX425052
EVLSCX432052
EVLSCX42072
EVLSCX43072

EVLSBX425070
EVLSBX432070
EVLSBX42100
EVLSBX43100

EVLSBX425071
EVLSBX432071
EVLSBX42101
EVLSBX43101

EVLSBX425072
EVLSBX432072
EVLSBX42102
EVLSBX43102

EVLSCX425070
EVLSCX432070
EVLSCX42100
EVLSCX43100

EVLSCX425071
EVLSCX432071
EVLSCX42101
EVLSCX43101

EVLSCX425072
EVLSCX432072
EVLSCX42102
EVLSCX43102

EVLSBX425100
EVLSBX432100
EVLSBX42150
EVLSBX43150

EVLSBX425101
EVLSBX432101
EVLSBX42151
EVLSBX43151

EVLSBX425102
EVLSBX432102
EVLSBX42152
EVLSBX43152

EVLSCX425100
EVLSCX432100
EVLSCX42150
EVLSCX43150

EVLSCX425101
EVLSCX432101
EVLSCX42151
EVLSCX43151

EVLSCX425102
EVLSCX432102
EVLSCX42152
EVLSCX43152

EVLSBX425150
EVLSBX432150

EVLSBX425151
EVLSBX432151

EVLSBX425152
EVLSBX432152

EVLSCX425150
EVLSCX432150

EVLSCX425151
EVLSCX432151

EVLSCX425152
EVLSCX432152

Hub Size No Guard

Complete
Standard Voltage Ballasts
catalog
number
as follows: NEC/UL
CEC/CSA (cUL)
208V
Voltage
Multi-tap 120V 480V Tri-Tap 120V
CWI

240V
CWI

480V
CWI

600V
CWI

Suffix

/240CWI

/480CWI

/600CWI /220

990

/MT

/120

/480

www.crouse-hinds.com

/TT

/120

US: 1-866-764-5454

/208CWI

CAN: 1-800-265-0502

Export
220V
60 Hz

Copyright 2012 Cooper Crouse-Hinds

220V
50 Hz

240V
50 Hz

/220 50

/240 50

990-991.qxp

5/30/2011

10:07 AM

Page 991

EVLS HazardGard

Cl. I, Div. 1, Groups B


(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III & Simultaneous Presence

Compact & Rugged, Class I, Zone 1,


Div. 1 Explosionproof Luminaire

UL and cUL Listed


4L
Wet locations (UL1598),
Marine locations (UL1598A)
Type 4X, IP66

Ordering Information High Pressure Sodium (Cont'd):

ADAPTER

STANCHION

Wattage Hub Size


50W
70W
100W
150W

Adapter
11/2"
Adapter
11/2"
Adapter
11/2"
Adapter
11/2"

No Guard

Wire Guard

Cast Guard

EVLSJ45050

EVLSJ45051

EVLSJ45052

EVLSJ45070

EVLSJ45071

EVLSJ45072

EVLSJ45100

EVLSJ45101

EVLSJ45102

EVLSJ45150

EVLSJ45151

EVLSJ45152

No Guard

Wire Guard

Cast Guard

Luminaire less
mounting module
and guard

EVLSM4050

EVLSM4051

EVLSM4052

EVLS4050

EVLSM4070

EVLSM4071

EVLSM4072

EVLS4070

EVLSM4100

EVLSM4101

EVLSM4102

EVLS4100

EVLSM4150

EVLSM4151

EVLSM4152

EVLS4100

Complete
STANDARD VOLTAGE BALLASTS
catalog
number as
NEC/UL
CEC/CSA (cUL)
follows:
Voltage

Multi-tap 120V 480V

Tri-Tap 120V 208V


CWI

Suffix

/MT

/TT

/120

/480

/120

Export

/208CWI

240V
CWI

480V
CWI

600V
CWI

220V
60 Hz

/240CWI

/480CWI

/600CWI /220

220V
50 Hz

240V
50 Hz

/220 50

/240 50

4L

Photometrics - EVLS High Pressure Sodium


Fixture with Globe and Domed Reflector (less guard) EVLSA42150RD725
Lamp: 150W/B17 High Pressure Sodium (HPS)

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

991

992-993.qxp

5/30/2011

10:08 AM

Page 992

4L EVLS HazardGard
Compact & Rugged, Class I, Zone 1,
Div. 1 Explosionproof Luminaire

Cl. I, Div. 1, Groups B


(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III & Simultaneous Presence

Photometrics - EVLS High Pressure Sodium:


Fixture with Globe and Guard EVLSA42151
Lamp: 150W/B17 High Pressure Sodium (HPS)

Photometrics - EVLS High Pressure Sodium:

4L

Fixture with Globe and Angled Reflector (less guard) EVLSA42150RA725


Lamp: 150W/B17 High Pressure Sodium (HPS)

992

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

UL and cUL Listed


Wet locations (UL1598),
Marine locations (UL1598A)
Type 4X, IP66

992-993.qxp

5/30/2011

10:08 AM

Page 993

EVLS HazardGard
Compact & Rugged, Class I, Zone 1,
Div. 1 Explosionproof Luminaire

Cl. I, Div. 1, Groups B


(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III & Simultaneous Presence

UL and cUL Listed


4L
Wet locations (UL1598),
Marine locations (UL1598A)
Type 4X, IP66

Ordering Information Pulse Start Metal Halide:

Wattage Hub
Size

150W

175W

3/4"
1"
11/2"
25 mm
32 mm
3
/4"
1"
11/2"
25 mm
32 mm

No Guard

PENDANT
Wire Guard

Cast Guard

No Guard

BULKHEAD
Wire Guard

Cast Guard

EVLSA92150-S828
EVLSA93150-S828

EVLSA92151-S828
EVLSA93151-S828

EVLSA92152-S828
EVLSA93152-S828

EVLSBH92150-S828

EVLSBH92151-S828

EVLSBH92152-S828

EVLSA925150-S828
EVLSA932150-S828
EVLSA92170-S828
EVLSA93170-S828

EVLSA925151-S828
EVLSA932151-S828
EVLSA92171-S828
EVLSA93171-S828

EVLSA925152-S828
EVLSA932152-S828
EVLSA92172-S828
EVLSA93172-S828

EVLSBH925150-S828 EVLSBH925151-S828

EVLSBH925152-S828

EVLSBH92170-S828

EVLSBH92172-S828

EVLSA925170-S828 EVLSA925171-S828 EVLSA925172-S828


EVLSA932170-S828 EVLSA932171-S828 EVLSA932172-S828

EVLSBH925170-S828 EVLSBH925171-S828

EVLSBH92171-S828

EVLSBH925172-S828

Ordering Information Pulse Start Metal Halide:

4L

Wattage Hub
Size
3
/4"
1"
11/2"
150W
25 mm
32 mm
3
/4"
1"
175W
11/2"
25 mm
32 mm

No Guard

WALL
Wire Guard

Cast Guard

No Guard

CEILING
Wire Guard

EVLSBX92150-S828
EVLSBX93150-S828

EVLSBX92151-S828
EVLSBX93151-S828

EVLSBX92152-S828
EVLSBX93152-S828

EVLSCX92150-S828
EVLSCX93150-S828

EVLSCX92151-S828 EVLSCX92152-S828
EVLSCX93151-S828 EVLSCX93152-S828

EVLSBX925150-S828
EVLSBX932150-S828
EVLSBX92170-S828
EVLSBX93170-S828

EVLSBX925151-S828
EVLSBX932151-S828
EVLSBX92171-S828
EVLSBX93171-S828

EVLSBX925152-S828
EVLSBX932152-S828
EVLSBX92172-S828
EVLSBX93172-S828

EVLSCX925150-S828
EVLSCX932150-S828
EVLSCX92170-S828
EVLSCX93170-S828

EVLSCX925151-S828
EVLSCX932151-S828
EVLSCX92171-S828
EVLSCX93171-S828

Cast Guard

EVLSCX925152-S828
EVLSCX932152-S828
EVLSCX92172-S828
EVLSCX93172-S828

EVLSBX925170-S828 EVLSBX925171-S828 EVLSBX925172-S828 EVLSCX925170-S828 EVLSCX925171-S828 EVLSCX925172-S828


EVLSBX932170-S828 EVLSBX932171-S828 EVLSBX932172-S828 EVLSCX932170-S828 EVLSCX932171-S828 EVLSCX932172-S828

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

993

994-995.qxp

5/30/2011

10:09 AM

Page 994

4L EVLS HazardGard
Compact & Rugged, Class I, Zone 1,
Div. 1 Explosionproof Luminaire

Cl. I, Div. 1, Groups B


(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III & Simultaneous Presence

UL and cUL Listed


Wet locations (UL1598),
Marine locations (UL1598A)
Type 4X, IP66

Ordering Information Pulse Start Metal Halide (Cont'd):

STANCHION

4L

Hub
Wattage Size
Adapter
3
/4"
1"
150W
11/2"
25 mm
32 mm
Adapter
3
/4"
1"
175W
11/2"
25 mm
32 mm

No Guard

Wire Guard

ADAPTER

Cast Guard

Wire Guard

Cast Guard

EVLSM9150-S828 EVLSM9151-S828 EVLSM9152-S828 EVLS9150-S828

EVLSJ95150-S828 EVLSJ95151-S828 EVLSJ95152-S828

EVLSM9170-S828 EVLSM9171-S828 EVLSM9172-S828 EVLS9100-S828


EVLS9170-S828
EVLSJ95170-S828 EVLSJ95171-S828 EVLSJ95172-S828

Complete
catalog
Standard Voltage Ballasts
number as
NEC/UL
follows:
Multi-tap
120V
Voltage

480V

Suffix

/480

994

No Guard

Luminaire
less
mounting
module and
guard

/MT

www.crouse-hinds.com

/120

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

994-995.qxp

5/30/2011

10:09 AM

Page 995

EVLS HazardGard

Cl. I, Div. 1, Groups B


(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III & Simultaneous Presence

Compact & Rugged, Class I, Zone 1,


Div. 1 Explosionproof Luminaire

UL and cUL Listed


4L
Wet locations (UL1598),
Marine locations (UL1598A)
Type 4X, IP66

Ordering Information Metal Halide:

PENDANT
Wattage

70W

100W

175W

Hub Size
3
/4"
1"
11/2"
25 mm
32 mm
3
/4"
1"
11/2"
25 mm
32 mm
3
/4"
1"
11/2"
25 mm
32 mm

BULKHEAD

No Guard
EVLSA92070
EVLSA93070

Wire Guard
EVLSA92071
EVLSA93071

Cast Guard
EVLSA92072
EVLSA93072

No Guard
EVLSBH92070

Wire Guard
EVLSBH92071

Cast Guard
EVLSBH92072

EVLSA925070
EVLSA932070
EVLSA92100
EVLSA93100

EVLSA925071
EVLSA932071
EVLSA92101
EVLSA93101

EVLSA925072
EVLSA932072
EVLSA92102
EVLSA93102

EVLSBH925070

EVLSBH925071

EVLSBH925072

EVLSBH92100

EVLSBH92101

EVLSBH92102

EVLSA425100
EVLSA432100
EVLSA92170
EVLSA93170

EVLSA425101
EVLSA432101
EVLSA92171
EVLSA93171

EVLSA425102
EVLSA432102
EVLSA92172
EVLSA93172

EVLSBH425100

EVLSBH425101

EVLSBH425102

EVLSBH92170

EVLSBH92171

EVLSBH92172

EVLSA925170
EVLSA932170

EVLSA925171
EVLSA932171

EVLSA925172
EVLSA932172

EVLSBH925170

EVLSBH925171

EVLSBH925172

Complete
Standard Voltage Ballasts
catalog
number
CEC/CSA (cUL)
as follows: NEC/UL

Export

Multi-tap

120V

480V

Tri-Tap

120V

Suffix

/MT

/120

/480

/TT

/120

/208CWI

www.crouse-hinds.com

240V
CWI

480V
CWI

600V
CWI

220V
60 Hz

220V
50 Hz

240V
50 Hz

/240CWI

/480CWI

/600CWI

/220

/220 50

/240 50

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

4L

Voltage

208V
CWI

995

996-997.qxp

5/30/2011

4L

10:11 AM

Page 996

EVLS HazardGard
Compact & Rugged, Class I, Zone 1,
Div. 1 Explosionproof Luminaire

Cl. I, Div. 1, Group B


(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III &
Simultaneous Presence

UL and cUL Listed


Wet locations (UL1598)
Marine locations (UL1598A)
Type 4X, IP66

Ordering Information Metal Halide (Cont'd):

WALL
Wattage

70W

100W

4L

175W

Hub
Size
3
/4"
1"
11/2"
25 mm
32 mm
3
/4"
1"
11/2"
25 mm
32 mm
3
/4"
1"
11/2"
25 mm
32 mm

CEILING

No Guard
EVLSBX92070
EVLSBX93070

Wire Guard
EVLSBX92071
EVLSBX93071

Cast Guard
EVLSBX92072
EVLSBX93072

No Guard
EVLSCX92070
EVLSCX93070

Wire Guard
EVLSCX92071
EVLSCX93071

Cast Guard
EVLSCX92072
EVLSCX93072

EVLSBX925070
EVLSBX932070
EVLSBX92100
EVLSBX93100

EVLSBX925071
EVLSBX932071
EVLSBX92101
EVLSBX93101

EVLSBX925072
EVLSBX932072
EVLSBX92102
EVLSBX93102

EVLSCX925070
EVLSCX932070
EVLSCX92100
EVLSCX93100

EVLSCX925071
EVLSCX932071
EVLSCX92101
EVLSCX93101

EVLSCX925072
EVLSCX932072
EVLSCX92102
EVLSCX93102

EVLSBX425100
EVLSBX432100
EVLSBX92170
EVLSBX93170

EVLSBX425101
EVLSBX432101
EVLSBX92171
EVLSBX93171

EVLSBX425102
EVLSBX432102
EVLSBX92172
EVLSBX93172

EVLSCX925100
EVLSCX932100
EVLSCX92170
EVLSCX93170

EVLSCX925101
EVLSCX932101
EVLSCX92171
EVLSCX93171

EVLSCX925102
EVLSCX932102
EVLSCX92172
EVLSCX93172

EVLSBX925170
EVLSBX932170

EVLSBX925171
EVLSBX932171

EVLSBX925172
EVLSBX932172

EVLSCX925170
EVLSCX932170

EVLSCX925171
EVLSCX932171

EVLSCX925172
EVLSCX932172

Complete
catalog
number as
follows:

Standard Voltage Ballasts

Voltage

Multi-tap 120V

480V

Tri-Tap

120V

208V
CWI

240V
CWI

480V
CWI

600V
CWI

220V
60 Hz

220V
50 Hz

230V*
50 Hz

240V
50 Hz

Suffix

/MT

/480

/TT

/120

/208CWI

/240CWI

/480CWI

/600CWI

/220

/220 50

/230 50

/240 50

NEC/UL

/120

CEC/CSA (cUL)

Export

*Available for 175W only.

996

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

996-997.qxp

5/30/2011

10:11 AM

Page 997

Cl. I, Div. 1, Group B


(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III &
Simultaneous Presence

EVLS HazardGard
Compact & Rugged, Class I, Zone 1,
Div. 1 Explosionproof Luminaire

UL and cUL Listed


Wet locations (UL1598)
Marine locations (UL1598A)
Type 4X, IP66

4L

Ordering Information Metal Halide (Cont'd):

STANCHION

Wattage
70W
100W
175W

Complete
catalog
number as
follows:

Hub
Size
Adapter
11/2"
Adapter
11/2"
Adapter
3
/4"
11/2"

No
Guard

Wire
Guard

ADAPTER
Cast
Guard

EVLSJ95070 EVLSJ95071

EVLSJ95072

EVLSJ95100 EVLSJ95101

EVLSJ95102

EVLSJ95170 EVLSJ95171

No Guard
Wire Guard
EVLSM9070 EVLSM9071

Cast Guard
EVLSM9072

Luminaire less
mounting module
and guard
EVLS9070

EVLSM9100 EVLSM9101

EVLSM9102

EVLS9100

EVLSM9170 EVLSM9171

EVLSM9172

EVLS9100
EVLS9170

EVLSJ95172

Standard Voltage Ballasts


NEC/UL

CEC/CSA (cUL)

Voltage

Multi-tap

120V

480V

Tri-Tap

120V

208V
CWI

Suffix

/MT

/120

/480

/TT

/120

/208CWI

Export

240V
CWI

480V
CWI

600V
CWI

220V
60 Hz

220V
50 Hz

230V*
50 Hz

240V
50 Hz

/240CWI

/480CWI

/600CWI

/220

/220 50 /230 50 /240 50

*Available for 175W only.

EVLS Metal Halide:

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

4L

Fixture with Globe and Domed Reflector (less guard) EVLSA92170RD725


Lamp: 150W/ED17 Metal Halide (MH)

Copyright 2011 Cooper Crouse-Hinds

997

998-999.qxp

4L

6/13/2011

10:35 AM

Page 998

EVLS HazardGard
Compact & Rugged, Class I, Zone 1,
Div. 1 Explosionproof Luminaire

Cl. I, Div. 1, Group B


(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III &
Simultaneous Presence

EVLS Metal Halide:


Fixture with Globe and Guard EVLSA92171
Lamp: 175W/ED17 Metal Halide (MH)

EVLS Metal Halide:

4L

Fixture with Globe and Angled Reflector (less guard) EVLSA92170RA725


Lamp: 175W/ED17 Metal Halide (MH)

998

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

UL and cUL Listed


Wet locations (UL1598)
Marine locations (UL1598A)
Type 4X, IP66

998-999.qxp

6/13/2011

10:35 AM

Page 999

Cl. I, Div. 1, Group B


(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III &
Simultaneous Presence

EVLS HazardGard
Compact & Rugged, Class I, Zone 1,
Div. 1 Explosionproof Luminaire

UL and cUL Listed


Wet locations (UL1598)
Marine locations (UL1598A)
Type 4X, IP66

4L

Dimensions - Shown with new mounting modules:


10.97

3.16

15

16.47

16.36
16.97

17.85

.61
8.47

.61

BULKHEAD MOUNT

CEILING MOUNT

4.11

15.45

3.61

25

17.43
8.28

17.18

16.82

4L

.61

13.78
15.45

8.47

STANCHION MOUNT

.61

PENDANT MOUNT

9.51

16.78
17.39

8.47

.61

WALL MOUNT

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

999

1000-1001.qxp

4L

5/30/2011

10:13 AM

Page 1000

EVLS HazardGard

Cl. I, Div. 1, Group B


(with suffix GB), C, D
Cl. I, Zone 1, Group IIB + H2
(with suffix GB)
Cl. II, Cl. III &
Simultaneous Presence

Compact & Rugged, Class I, Zone 1,


Div. 1 Explosionproof Luminaire

UL and cUL Listed


Wet locations (UL1598)
Marine locations (UL1598A)
Type 4X, IP66

Dimensions - Shown with existing mounting modules plus EVSA Adapter:


11 15/16"

15
18 5/8"
19 3/16"
21 5/8"

CEILING MOUNT EV22, EV33


BULKHEAD MOUNT EVJ2

18 7/16"

19 1/16"
19 11/16"

20 1/16"
19 9/16"

4L

25

8 7/16"

STANCHION MOUNT EVMJ4

PENDANT MOUNT EVMP2, EVMP3

9 1/2"

3 5/16"

19"

19 5/8"

WALL MOUNT BRACKET EV87

1000

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

Cl. I, Div. 2, Groups A, B, C, D


Maintains Cl. I, Div. 2 Suitability of Cooper
Crouse-Hinds Champ Series Luminaires

Photocells

3L

V2PC, D2S and EV2IH Series


The only UL recognized photocells for Class I, Division 2 areas.
Eliminates the need for an explosionproof box!
Cooper Crouse-Hinds factory-sealed, field installed photocells offer
reliable, dusk-to-dawn lighting control in Class I, Division 2 locations.
These photocells are ideal for walkways, security lighting, and any
other outdoor lighting application that utilizes Champ H.I.D. lighting
luminaires.

Applications:
Cooper Crouse-Hinds photocells are designed:
To provide control for automatic dusk-to-dawn lighting.
For safety by turning on outdoor luminaires in critical passageways
at night.
To save energy by operating luminaires only when necessary.
For walkways, parking areas, outdoor process areas, security
lighting, or any outdoor lighting application in Class I, Division 2
locations and corrosive environments.
For use with LMV, DMV, VMV, VMV High Wattage, and FMV Series
Champ lighting luminaires (V2PC Series).
For use on 35400 watt H.I.D., incandescent, or fluorescent
lighting luminaires.

Certifications and Compliances:


V2PC Series and D2S Series
NEC/CEC:
Class I, Division 2, Groups A, B, C, D

For remote mounting in FS boxes (D2S Series).

UL Standard: 844 Hazardous (Classified) Locations

For mounting in EIH enclosures for Class I, Division 1 applications


(EV2IH Series).

CSA: C22.2 No. 55

Features:

EV2IH Series
NEC/CEC:
Class I, Division 1 and 2, Groups B, C, D

Field-installable.

Class II, Division 1, Groups E, F, G

Solid-state design for performance and dependability.

Class II, Division 2, Groups F, G

Factory sealed components.


Explosionproof enclosure not required for Class I, Division 2
locations.

UL Standard: 844 Hazardous (Classified) Locations

3L

Luminaires turn on at 3 footcandles, off at 8 footcandles insuring


that the luminaires are operating only when needed.

Class III
NEMA: 3, 4, 7BCD, 9EFG

CSA: C22.2 No. 30, 55

Built-in 10 second time delay to eliminate nuisance tripping.


Eight-year operating life.

Electrical Rating Ranges:

Furnished with 6" stranded 600 volt color coded wire leads.

120, 208, 220, 240, 277 VAC

Constructed from corrosion-resistant thermoplastic polyester.

50 / 60 Hz

Available on a DS cover for use with any FS/FD box (D2S Series).

35400 watt H.I.D., incandescent, or fluorescent

Available in an EIH enclosure for use in Class I, Division 1, Groups


B*, C, and D locations (EV2IH Series). No seals required.

V2PC20 3.3A max. current rating


V2PC22 1.8A max. current rating

*For Group B applications, seal within 11/2" of enclosure in accordance with Section 501-5 of
the National Electric Code.

www.crouse-hinds.com

V2PC27 1.4A max. current rating

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2012 Cooper Crouse-Hinds

979

980-981.qxp

5/30/2011

3L

10:01 AM

Page 980

Photocells

Cl. I, Div. 2, Groups A, B, C, D


Maintains Cl. I, Div. 2 Suitability of Cooper
Crouse-Hinds Champ Series Luminaires

V2PC, D2S and EV2IH Series


Ordering Information:
Photocell for field installation in lighting fixtures*
Cat. #

Voltage Range

Current Rating

V2PC20
V2PC22
V2PC27

120V, 50/60Hz
208240V, 50/60Hz
277V, 50/60Hz

3.3A
1.8A
1.4A

Photocell in DS cover for use with FS/FD box


Cat. #

Voltage Range

D2S20
D2S208 277

120V, 50/60Hz
208V-277V

Photocell in EIH enclosure for use in Class I, Division 1, Groups B, C, and D;


Class II, Division 1, Groups E, F, and G; and Class III locations
Cat. #

Voltage Range

EV2IH20
EV2IH208 277

120V, 50/60Hz
208-277V 50/60Hz

3L

Replacement Photocell for D2S Cover or EIH


Enclosure *
Cat. #

Voltage Range

Current Rating

V2PCT20
V2PCT208 277

120V, 50/60Hz
208V-277V 50/60Hz

8.33A
4.81A - 3.61A depending on voltage

* Must be factory installed in Canada.


When mounting in EIH enclosures for Class I, Division 1 applications (EV21H Series) seals are not required for Groups C & D.

Options:
To order luminaire with photocell factory installed:
1. Specify luminaire dedicated supply voltage (not MT, DT, or TT)
2. Add photocell Cat. No. to fixture Cat. No. as follows:
V2PC20
V2PC22
V2PC27
Example: VMVSJ070GP/120-V2PC20 is a 120V 60Hz luminaire with
a factory installed photocell.
Note: Only the V2PC is available as a factory installed photocell.

980

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

980-981.qxp

5/30/2011

10:01 AM

Page 981

Photocells

Cl. I, Div. 2, Groups A, B, C, D


Maintains Cl. I, Div. 2 Suitability of Cooper
Crouse-Hinds Champ Series Luminaires

3L

V2PC, D2S and EV2IH Series


Dimensions:
In Inches:
V2PC

EV2IH

V2PCT

D2S

Cat. #

EV2IH

5.00

4.25

2.60

4.54

5.25

3L

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright 2011 Cooper Crouse-Hinds

981

You might also like