1e02013 13:22 A F00333427368 P.005/013 i 0333427368 Removable Bullat Resistant Guard Hut SAPS CIPS (Version 2) April 2013 REMOVABLE BULLET RESISTANT GUARD HUT 1, Structural design & dimensions{ xe Dimensions" } Structural design: © According to SANS 10400 Code of Practice for the application of the National Building Regulations; or © Alternatively a heavy duty trailer to be in compliance of the Road ‘Transportation Act. Dimension: Approximately 4, 000mm x 2,500mm = 10m? Helght: According to SANS 10400 Code of Practice for the application of the National Building Regulations. 2. Material 2.4. Walls According to SANS 10400 Code of Practice for the application of the National Building Regulations. Insulated and fire resistant 'sandwich’ wall type (outer) Material: Galvanised Steel / Chromadeck to prevent long term corrosion in coastal and other areas Thickness: (outside) To provide ballistic protection against 7,62 mm x 51 mm (R1.308) Fill: Granite chip Sand / Composite material/ Chromadeck: To provide ballistic protection against 7,62 mm x 61 mm (R1/,308) Finishing: High level of corrosion resistance to prevent long term corrosion In coastel and other areas. ‘The interior shall be insulated and sound proofed along the entire interlor eurface ‘area with a Sondor type *Soundseal" or similar approved to ensure flame and dust resistance. [Soncior Industries (PTY) LTD) 18/10/2013 13:22 o (FAXM393427368 P.008/013 0333427368, Removable Bullet Resistant Guard Hut SAPS CIPS (Version 2) April 2013, 22 23. 2.3.4. The ballistic capability of the walls must be tested at a SABS approved testing facility. Glass Weatherproof luminaire Tilted glazing — Desk lamp (cinmable) BRG glazing SANS 1263-part 3 Class RB. Glazing must provide protection against: 7.62mm X 51mm (R1/ .308). 800 mm x 900 mm (approximate). Minimum of 4 window panels to allow for 180 degree visual access. A one-way mirror type glass can be used to ensure the concealment of the occupants. (reverse effect at night as a result of illumination changes) The glass must be slanted/ angled away at approximately 15 to 20 degrees to the vertical to prevent reflections of light coloured objects ‘obstructing the police member's view of the outside. A_ ose ‘igure 1.SANS 10389-22007 £6! on 1.3 gure 7,37 Doors External doors Security door with BRG view panel and abiution door. Glazing must provide protection against 7.62mm X §1mm (R1 / .308) and the door must camply with the British G3 standard, fitted with a security key registered deadlock, 18/10/2013, 13:22 “ (F90333427368 007/013 0333427368 Removable Bullet Resistant Guard Hut SAPS CIPS (Version 2) April 2013, i Picture 3: Example of Security door 2.3.2. Interior doors Two sliding or single leaf solid wooden doors SANS 646:1989 class 1 2.4, IMlumInation Ail Illumination at the guard hut must be in compliance with SANS: 10389-2:2007 Edition 1.1. A number of important aspects pertaining to lighting sre however highlighted in paragraphs 2.4.1. to 2.4.3, infra Lux-levels, for Security, Domestic & Emergency ilumination, to be determined by an illumination Technologist. 2.44. Inside guard hut * Illumination is Important and it is essential thet the lighting level inside the guard hut is lower than that on the outside. © The Interior paint finish shall be in a dark colour and the lighting of the work surface, well shielded. ©. Lighting should be above the working surface end on a dimming device within easy reach, 2.4.2, Outside * The use of low brightness down lights away from the main tinted window is recommended to prevent that the fiting create bright spots on the window. ‘BRICKLIGHT’ type fittings around the guard house at approximately 350mm above finish floor level to "wash" the area should additionally be installed Refer to (BEKA (Pty) Lt}. © Abright spotiight/ floodiight to illuminate the area in front of the guard hut should be installed on the outside. Make sure that the surrounding light outside is brighter than inside during night time, © The use of energy saving LED technology is proposed. 18/10/2013, 13:22 a Fanoass4z7368 P.008/013 0333427368 Removable Bullet Resistant Guard Hut SAPS CIPS (Version 2) ‘Apri 2013 * _ Dayinight light sensor. 2.4.3, Checkpoint lighting [SANS 10389-2:2007 Edition 1.1] 26. 26. * The illumination of entry/exit areas, (checkpoints), shall be significantly higher than that of the adjoining area or perimeter fence and designed to allow easy identification of persons in vehicles, or on foot and comprehensive checking of vehicles, goods and documents. ¢ The lighting shall be arranged on both sides of the entrance to ensure adequate cover all around the vehicle, The use of street lighting luminaries 's recommended to avold glare causing a hazard to drivers entering or leaving the premises, or to security personnel in the execution of their duties. * Vandal proof bulkhead or fluorescent luminaries mounted above the guard hut window will enable police members to see into the driver's cab. * By coating the road surface with a light-coloured paint, light le reflected upward and facilitates inspection of the underside of vehicles. Roof The roof finishes, pitch, overhang, etcetera to be determined. Roof to provide ballistic protection against 7,62 mm x 51 mm (R4/.308), Floor Rubber/ non-slip, durable, fire retardant floor covering In all areas. Synthetic rubber ‘SaarFloor Noppe Stud tile’ © Copyright Polyfor Ltd 2010) or sitnilar. The tile shall be anti-static and easy cleanable. Colour to be determined. A material sample shall be presented to the SAPS for approval. 1871012013 13:23 ai ane333477368 P.009/013 0333427368 Removable Bullet Resistant Guard Hur SAPS CIPS (Version 2) April 2013 27, 42, 43, 44, Picture 2: SearFloce Noppa Stud la, sample Paint Paint colour and finish to be determined (both inside and outside). Alr conditioner 1 x AC/ Heater Combo with wall mount control unit Inside Control Room (relevant BTU would be determined by size of work area). Air conditioner for IT Cabinet (see paragraph 7 infra). Kitchenette (Approximately 2m?) Lightweight, durable and scratch-resistant utility counter. Dimensions to be determined, Standard type, powder coated steel kitchen cupboard sink unit- with sit-on type stainless steel sink and with steel sliding doors. Taps type to bo determined. “Hydroboil (FrankeSA, wiyw.zip.co.za} 2.5 litre or similar. ing 6 Figure 2:Schema cs of Hydroboll Installs on (wronw.2tp.c028) Pleturo 3: Hydrobolt,2.5 litre 18/10/2013 13:23 is 190383427388 P.o107013 0333427368 Removable Bullet Resistant Guard Hut SAPS CIPS (Version 2) ‘April 2013 4.5. Tiled splash-back, 300mm high 4.8. Additional cupboard above sink. Type to be determined, 4,7. Electrical power socket (220/240V) 4.8. Light. 5. Bathroom (Approximately 2.4m?) 5.1. Stainless stee! WC pan with pressed flushing rim and Integral 6s 110mm “P" trap and back entry flush pipe Inlet, complete with stainless steel cistem, seat and lid. 5.2, Integrated odour removal system’ ventilation system as “fresh flow’ or similar. 5.3. Stainless steel wall mounted whb, complete with taps. 5.4, Stainless steel towel rail 5.6. Stainless stee! lockable tollet paper dispenser. 5.6, Stainless steel liquid soap dispenser. 8.7. Dustbin 5.8. Two standard sheet metal lockers: epoxy coated, hasp-staple lock. 5.9. Ventilation gril aitbricks. 5.10. Light. 6. Control Room (Approximately 6.5m?) 6.1. Lightweight, durable and scratch-resistant counter top. Dimensions to be determined, 'U' or‘L’ shaped. 6.2. Under counter top (storage shelf), 300mm. 6.3, 2-channel, 2-cover power skirting above counter with dedicated socket-outlets. 6.4, Two powder coated steel drawer units/ cupboard-combo; ona each on both sides under counter. 6.5. Additional cupboard and/ or shelves (providing space exists). 66. Fixed Srrifle safe to SAPS specifications fixed to wall and floor. Safe (approximately 1448mm/360mm/300mm) to accommodate two assault rifles with extended butt; shelve for handguns and ammunition. The fixed templete to secure the rifle safe must be in compliance with the Firearm Control Act (60 of 2000) and SAPS Standing Order (Stores) 21 par 16. 19/10/2013 13:23 _ FaN00383427368 P.011/013 a 0333427368 Removable 6ullet Resistant Guard Hut SAPS CIPS (Version 2) ‘April 2013, Picture 4: Example of Rl e safe (1448/350/300) 6.7. Intercom system, 6.8. Mounted 4.5kg DCP fire extingulsher. 6.9. Mounted 1" Aid Kit. 6.10. Notice Board (1000mm/1000mm). 6.11. Emergency light, 6.12, Luminalre to be in compliance with SANS 10389-. 6.13. LED work tight (dimmable) 6.14, Airbricks. 6.16, Mounting panels for CCTV monitors (2), SAPS 2.way radio, intercom and telephone, 6.16. Conduil/ sleeves and fixing brackets to allow for the securing of wiring for radio communication system, antennae (roof), CCTV system, access control and security systems, fence energiser, power reticulation, etcetera. 6.17. Electrical DB. 6.18. Rifle ports to be considered. Rifle ports with a size of 150mmx160mm shall be Provided on at least three sides of the guard hut. The rifle ports shall allow firing angles of at least 45 * in all directions in front of the port. 2007 Edition 1.1. 18/10/2013 13:23, - (F49)0333427368 P.o12i013 “ 0333427368 Removable Bullet Resistant Guard Hut SAPS CIPS (Version 2) April 2013 Figure 4: RI e port- Inside view Figure 4: RI € port» outside view 6.19. A spotlight shall be fitted on top of the guard hut. The spotlight shall be operated from within the hut with an arc of 360°. Operation of the light shall be done by hand from the inside. The spotlight shall protrude at leest 150mm above the roof, 7. \T Cabinet Removable and externally fitted IT Cabinet with IP 65 rating: ‘Envirorack” or similar product. Picture 5: Example of envirorack’ 18/10/2013 13: a agoss377368 P.013/013 “ 0333427368 Removable Bullet Resistant Guard Hut SAPS CIPS (Version 2) April 2013 8 Concrete apron 1000mm x 100mm conerete apron around guard hut. 8. Annexure A — Proposed layout not to scal 91, Annexure B- Bullet Resistant Glazing; 9.2. Annexure C- Bullet Resistant Security Ooor, 10. Proviso 10.1. Drawings are for information purposes only and should be adapted to suit each particular site 10.2, Drawings are not to scale and measurements are approximate. The Architectural drawings, based on the user requirements, must be presented to SAPS Security Advisory Service for approval 10.3, The Control Room size should be increased should space be saved in other areas. 10.4. The outcome should be discussed with SAPS Security Advisory Service prior to implementation. 10.5. The exact position of the building (including fencing, gates, etc.) on each site, to be discussed with SAPS Security Advisory Service 10.6. The server and air conditioner must be located in a dedicated insulated location inside the IT Cabinet to ensure an ideal operating environment (dust and noise free). The energiser must be installed In @ suitable external housing adjacent to the guard hut. 10.7. All access doors to be located within the safe (secure) side of the perimeter fence. 10.8. All materials and work to be done according to PW 371- “Specification of Materials and Methods to be used”. Note and Disclaimer The graphics featured in this annexure may resemble similarities with Off-the-shelf and high-end user products. This is only done for detailing purposes, Similar Products complying with the relevant SABS or equivalent standards may also be used,

You might also like