SPECIFICATION FOR BEDD
DOC.No. : A11226-PR-10
DEMONSTRATION H2 PSA
UNIT AT VR _
Date of Issue : Oct 12. 2012
Rev.No: 4
Job No. : A11226 Page : 22 of 47
5.1.2.4.2
5.1.2.1.3
51214
5.1.2.1.5.
- Maximum operating pressure + 2.0 kg/cm?g
= 3.5 kglom2g
2) For operating pressures above 7C kg/cm?g, design pressure shall be
as per designer and as permissible by applicable code
The design pressure calculated ac per 5.1.2.1.1 is at the location of
relieving device such as the top of a vertical vessel. The design pressure
at the bottom of the vessel and of associated pieces of equipment
shall be determined by adding applicable maximum operating liquid
heads and pressure gradients,
Vessels operating under vacuum shall be, in general, designed for an
external pressure of 1.033 kg/em®(a) and full internal vacuum, unless
otherwise specified. Vacuum design stipulations shall be as per section 5.3.
(VACUUM DESIGN CONSIDERATION)
Vacuum equipments shall be designed additionally for water filing / LP steam
flushing
Emergency vacuum pressure of 0.4 kg/cm2(a) can be considered by
designer based on the process requirements and assessment of transient
operations,
For a full liquid system at the discharge of a centrifugal pump, the
mechanical design pressure shall be as under:
Pdes = Pmax suction +