=| J
eo SPECIFICATION FOR BEDD ssomeee
EP Any Engineering
Docne- avzasenae | PEONSTRATION RZ PSR ous tien e120
Rev.No : 4 Job No. : A11226 Page : 25 of 47
However, based on process considerations and designer's own
practice, heat exchanger can be designed without upgrading design
pressure by providir g tube rupture pressure relief valve after getting consent
on case to case basis from owner.
For feed / effluent exchanger, the tubesheet and tubes in high pressure
service need not be designed for full design pressure of the
shell and / or channel provided these components can never
experience these conditions. The same should be designed for maximum
differential pressue expected. Designer must consider start-up.
shut-down and emergency —depressurising while deciding
maximum differential pressure.
In cases where shell side pressure is very low compared to
tube side, for stbsequent testing of tube bundle, additional facility like
spare shell for testng shall be considered.
5.1.2.2. MECHANICAL D=SIGN PRESSURE FOR STORAGE TANKS AND
ATMOSPHERIC VESSELS
5.1.2.2.1 Design pressure of storage tanks shall be in accordance with API-620,
API-650 and API-2C00 (latest editions), as appropriate.
5.1.2.2.2 Blanketed storage: tanks shall have a blanketing pressure of 150 mmwec,
unless a higher pressure is deemed necessary from process considerations.
The design pressure of | blanketed storage tanks shall be
determined to allow adequate overpressure for out-breathing and
emergency relief devices. The blanketed tanks shall also be designed for 50
mmwe vacuum.
5.1.2.3 MECHANICAL DESIGN TEMPERATURE
5.1.2.3.1 For system operating at or above 0 °C, the mechanical design temperature
;
“