shall be the higher of the following,
Tdes = 65°C
Tes Tmax + 28°C
Tdes = Trelief (excluding fire relief temperatures)
Where,
Tmax = Maximum operating temperature expected —_ considering
different possible operations for the equipment or system, including air
drying or gas drying conditions.
Trolief= Temperature corresponding to pressure relief conditions
for an operational failure case (specifically excluding fire relief case).
5.1.2.3.2 For system operating below 0 °C, the mechanical design temperature shall
be equal to the lowest anticipated operati ig temperature.
5.1.23.3 For pressure vessels storing refrigerants or liquefied hydrocarbons at
ambient temperature, the design temperature (based on depressurization) shall
correspond to the coincident design pressure when this lowest temperature is,
reached. The coincident design pressure can be different from the maximum
design pressure. specified for the vessel depending upon tre
system under consideration. However, if this calls for a change in
metallurgy, then other fool proof stratecies to avoid this situation shall oe
evaluated. Otherwise select the metalluray to suit the minimum temperature
5.1.2.3.4 For heat exchangers, consideration should be given to possible failure of
cooling medium and resultant impact of higher temperature on tubes,
tubesheets and floating head (inlet_maximum temperature). The design
temperature is highest anticipated temperature in such an event.
5.1.2.4 STEM-OUT CONDITIONS