oy SPECIFICATION FOR BEDD @ saseonezne AP hay ingineering DEMONSTRATION H2 PSA DOC.No. : A11226-PR-10 UNIT AT VR Date of Issue : Oct 12. 2012 Rev.No 24 Job No. : A11226 Page : 29 of 47 Shell side fouling resistance | Tube side fouling resistance | TEMA type (Hr-m?.°Cikcal) (Hr-m?-°Cikcal) (preferred) >0.0002 >0.0002 Floating head 20.0008 30.0002 Fixed tube sheet 30.0002 50.0002 Utube bundle Fixed tube sheet 7 U tube bundle 50.0002 0.0002 OR as specified by Licensor. 513.15. 5.1.3.1.6. All shell and tube t eat exchangers in a refinery application shall follow TEMA- R, unless required otherwise. Preferred exchanger type for refinery services shall be horizontal, single pass shell, floating head tube bundle (TEMA type 'S') arranged with two or more tube passes per shell Tube layout shall be square or rotated square for fouling services and triangular pitch for clean services (i.e. fouling factor <0.0002 Hr-m?-°Cik cal). General criteria for specifying U-tube construction shall be: -Services where steam is condensed or generated on tubeside; tube pitch shall be triangular if shell side fluid is clean and square / rotated square if shell side fluid is fouling - TEMA type B staionary head: hydrogen services or when steam or other clean fluid is on tube side, not requiring cleaning -TEMA type A stationary head when tube side fluid is cooling water or similar process fluids, requiring cleaning