Shell side fouling resistance | Tube side fouling resistance | TEMA type
(Hr-m?.°Cikcal) (Hr-m?-°Cikcal) (preferred)
>0.0002 >0.0002 Floating head
20.0008 30.0002 Fixed tube sheet
30.0002 50.0002 Utube bundle
Fixed tube sheet 7 U
tube bundle
50.0002 0.0002
OR as specified by Licensor.
513.15.
5.1.3.1.6.
All shell and tube t eat exchangers in a refinery application shall follow TEMA-
R, unless required otherwise. Preferred exchanger type for refinery services
shall be horizontal, single pass shell, floating head tube bundle (TEMA type 'S')
arranged with two or more tube passes per shell
Tube layout shall be square or rotated square for fouling services and
triangular pitch for clean services (i.e. fouling factor <0.0002 Hr-m?-°Cik cal).
General criteria for specifying U-tube construction shall be:
-Services where steam is condensed or generated on tubeside; tube pitch
shall be triangular if shell side fluid is clean and square / rotated square if
shell side fluid is fouling
- TEMA type B staionary head: hydrogen services or when steam or other
clean fluid is on tube side, not requiring cleaning
-TEMA type A stationary head when tube side fluid is cooling
water or similar process fluids, requiring cleaning