You are on page 1of 1
A aay Engineering ee SPECIFICATION FOR BEDD Q sasoeneme | Decne :arrzzsenso | DEMONSTRATION HZ PSA | ous rinue sont 21 Rev.No: 4 Job No. : A11226 Page : 30 of 47 - TEMA type B or C stationary heads shall not be used when design pressure is higher than 140 kg/em?(a). Tubesheet shall not be full diameter extended type when TEMA type B stationary heat! is used. - For U tube bundles, consideration shal be given for hydrotesting of tubes for IBR / normal testing after preventive maintenance. If necessary, dummy shell shall be designed for testing for maintenance purpose. 5.1.3.1.7. For design of coolers and condensers, consider normal cooling water temperature conditions ie supply temperature of 33 °C and return temperature 0f 44°C. 5.1.3.1.8. All sea cooling water exchangers shall have 2 shells operating in parallel, ‘each designed for 60% of duty and flow. However, this is not applicable where. twin lube oil coolers are provided. 5.1.3.2, PREFERRED SIZES FOR SHELL AND TUBE EXCHANGER WITH REMOVABLE BUNDLES. Nominal straight tube length: __6.0"') _meters 2) Maximum tube bundle diameter: _1.4°2) _ meters Maximum tube bundle weight: __15(°2) _ tons (1) alternate tube length may be used to improve design. (2) This limitation does not apply to vertical combined feed exchangers, vertical reboilers or fixed tubesheet type heat exchangers. Preferred tube dimensions: