You are on page 1of 7
TAR FOUNDATION RING WALL DESIGN CSA- A2B3-944 CCANADIAN CODB) 1.0 ENGINEERING AND DESIGN SKETCHES: & RING BEAM AND TANK INNER DIA. 1400 FGL TYPICAL CROSS SECTIONAL VIEW OF RING WALL FOUNDATION 2.0 DESIGN PARAMETERS (PER CANADIAN CODE CSA A23.3-94) Concrete Parameters Se eens conan eat ee reo = 40% ; fo 4 Sere ee eee eee adi late Factor tor corte jq=060 Fadertorveetorngtar, 4,» 088 Facer eonunt ks er deraty cress ee or @ TAR FOUNDATION RING WALL DESIGN CSA— A23B3-94 CCANAOLAN CopE) inforci ters ‘Specified Yield strength of Reinforcement, 400 MPa Elastic modulus of re-bar: = 200000 MPa ty Erebar Concrete Re-bar cover for pile, cover = 75 mm Anchor Bolt Parameters, Tensile strength of Anchor Bolt(A307), _-Fau_ap = 414 MPa Resistance fators for Anchorrods, ay = 067 sol Parameter Densiy oscil yyy = 210% Soi Heightunderthe Tank, Hyy =22m Densiy ofwater yy - 984 5 5 Allowable net Bearing Capacity, SBC yay gy = 200kPa Earth pressure coefficient at rest, k, = 0.45 etal 3.0 RING BEAM DESIGN: 3.1. TANK DATA (By Vendor) Inner dia. of Tank, 1D = $4870 mm Height of Tank, Hank = 17000 mm 0 Tank shell As built Metal load, Metal = 41781 % Corroded metal Load, Rooke Load, Ugg « st27™ snow Load, N . N Shelinsulation, Shelling = 1468 Roof insulation, Rooting = 485% N N Design Pressure, Prgxign = 27483 % External Design Vacuum = 3432 8 i m Pressure, iB Wind Load, Wind,yy = 12845 & Wind Shear, Shear = 461 kN Anchor Bolt dia. dyayy = 128 in Bolt circle dia, BCD = 55150 mm Total no of Bolts, gai, = 57 Total Wind Moment on ring wall foundation, Waygqy = 3936 KN m Maximum design Tension load on each Bolt, Tyajp= 19.7 KN (Design tension) TANK FOUNDATION RING WALL DESIGN CSA— A233-94 CCARADIAN CODE) Load on tank Bottom Plate: Product Static Pressure Pry = 150 kPa Bottom Plate Static Pressure, Pray, = 0.7 KPa Internal Design Pressure Prg = 20 KPa 3.2 Detail of Ring Beam (Refer sketch above ‘Assumption: Tank inner dia is considered as the centerline dimension of foundation ring beam. Depth of Ring Beam Depth = 2200 mm Width of Ring Beam, Width = 600 mm Inner dia of Ring Beam, Ring) 54270 mm, D— Width ——Ringy Outer dia of Ring Beam, —Ringgp) = ID + Width 3.3 Load Cases and Load Combinations: Following load cases and load combinations are considered for ring beamn design, Load cases: 1.0 Self Weight of the Tank (SW) 2.0 Wind Load (WL) 3.0 Product Weight (PW) 4.0 Operating Design Pressure in the tank (DP) 5.0 Vacuum Pressurein the Tank (empty condition) (VP) Load Combinations for Soil Bearing Pressure Check: LC1: SW+PW Loz; SW+PWHOP+SL. LC3: SW (corroded)+WL. LC4: SW (corroded)+WL+VP Load Combinations for Ring Beam design ULCT: 1.5*SW+1t S*PW#1.5°0P 3.4 — Ring Beam Sizing Check and Soil Beari check: ‘+ Design of ring wall shall ensure that the average soil stress under the ring wall shall be equivalent to the average Unit soil stress under the confined earth at the same depth ‘+ The thickness of ringwall shall be determined based on the soil bearing capacity. To reduce differential settlement, the long term bearing pressure beneath the wall and the tank shall be equal ‘+ Reinforced concrete ringwalls shall be designed in accordance CSA A23.3-94. The minimum thickness of reinforced concrete ringwalls shall be 500 mm, TANI FOUNDATION RING WALL DESIQN CSA- A233-949 CCARADIAN CODE) Soil net Bearing Pressure at 22m depth, SBC, wet alt = 200 KPa Soll Gross Bearing pressure at 22m depth, SBCyross atl = SBCyet all * Yooil 95M — SBCgrogg ai = 210.5KPa LOAD COMBINATION #LC1:_sWw+Pw. Metal + Shelling + Roofing Pest Load under Ring Beam, SBC St teone Depth SBCying_ 1 ~ 200.69 KPa ving_t Width Bearing Pressure Check, SBC ig 1 if(SBCfgg 1 SHC yous in"OK™. CHECK") SC uecg 1 = "OR" Soil Bearing pressure under the tank, SBCagg 1 = Pry Pat * Maat Yo S1Cank 1 = 1969KPa Bearing Pressure Check, SBCnocy 9 = Hf(SBC any j & SBC, SOK" ,*CIIECK") SBCyaqy 3= "0K" ‘gross_all LOAD COMBINATION #LC2_SW#PW+DP+SL. Metal + Shellin, + Roofing + SL + Pr, ins + Ro°fing design fing 2° ‘Width 2 Load under Ring Beam, SBC, SBC;ing 2 = 167:56Pa Bearing Pressure Check, SBC.necy 3 = it (SBCyiy 1hs"0K" ,"CHECK™) SBCyygcy 3 = 70K" Soil Bearing pressure under the tank, SBC, ott Prat + Pg + Hoot Yeoit SBCyank_2 = 198.9KPa Bearing Pressure Check, 8BC ioc, 4 = SBCank 2 £ SBC, ‘gross alls"OK" CHECK") SBC agg 4 = "OK" LOAD COMBINATION #LC3_SW (corroded)+ WL Metal Wenom (08 Rig Load under Ring BESM, SBCng 3-may [et + Yeone Dent) + —Yemom (0S Ringoo) wt ‘Width: sone 2 Bpin 4 Ri +) ea iRingop ~ Ringyp $B Cying max 111-94 KPa ( Mealy Wnam (05 Ri Load underRing Beam. S8Cjg. min ~ (ea » Siro (05 Ringo) ing_3_min ~ | Wah a 7 a) Fa VRingop ~ Ringyp') SBCying 3 min =10633kPa_((No tension) Bearing Pressure SBCheex $= if(SBCing 4a ©SBCyrns ae"OK"."CHECK") SBC ay 5 = 70K" Check, @4@ TARK FOUNDATION RING WALL DBSIGN CSA— A2LBD-IF CCATRCADIAN Cope) LOAD COMBINATION #LC4_ SW (corr +VvP (Meta Load under Ring Beam, SBC; = ring 4_max = | Wig 7 9 Ringo’ ~ Ring} SBCying_4_max = 117-66 KPa Metiloge Wom (0-5 Rin + eame Deh + ) mom (05 Ringo) Load under Ring Beam, SBC, ing 4 min (tisgop! Rip gatRinson ~ Ringyy ) \Wiath SBC, =112.05kPa (No tension) ring 4_min Bearing Pressure Check, SBCoheck 6 = if(SBCyin ng 4 as 5g "OK" CHECK") Bearing pressure under ring beam and tank pad is compared for Load combination no. LC1 and found SBC values are close to each other. Hence, width of ring beam is ok. However, ring beam width shall be checked for anchor bolt. 35 tension Calculation forRing Beam © ULC1:_1.5*SW+1.5*PW+1.5°0P RING BEAM SURCHARGE SOIL PRESSURE WATER PRESSURE LATERAL PRESSURE ON RING WALL Pressure on wall due to weight of product and base plate, Lsges = hy (Prpte + Pret) pres. = 67.81 KPa Pressure on wall due to design pressure inside the tank, La 9 = hy (Pra) pres? = 0.9KPa © 4@ TANK FOUNDATION RING WALL DESIGN CSA - A2B3-94 CCANADIAN Cope) Pressure on wall due to compacted sand fillinside the ring, 1 pres3 * Ko[Hoit(Yooit~Yw)] pres 3 = Pressure on wall due to water fill inside the ring, Lprest = (Heoit tu) L pres = 216K Lores3_. Lpres.t ) Total utimate Hoop Tension on Ring Beam, HT = 1.5 [yen + Upyena + EEE? « BEA | HT = 7699.05 kN BS Reinforcement Calculation for Ring Beam ANCHOR BOLT LENGTH - 1025 nm 425_| PROJ 10.30M TOP & BTM 11-30M. Ea sPco ASM @ 300 cic REBAR DETAIL OF RING WALL 36.1 Horizontal Rebar calculation, Hoop tension in the ring wall due to surcharge and compacted soil pressure shall be taken care by Horizontal Re-bar only, 1644.26 mm Ast HI ‘Area of re-bar required for Hoop tension, Ace it O#r® TANK FOURTDATION RAIN] WALL DASIGN CSA - A23:3- 94 COAMAOIAN CODE) Minimum horizontal rebar for vertical wall, (Refer cl#14.3.3) “Ha = 0.002 Depth Width Minimum Horizontal rebar required, — Axe Ht eg = (Mc 1A HB) Use 42 - 30M horizontal rebar, distributed on the wall faces as shown in the above sketch, Total Horizontal Rebar Provided, Agen prov = 42 Asp Ag H_proy = 200 mm? orion Rebar Check = if(Ay it prov ©Ax tt reqds"CHECK”.*OK") —_Horizotal_Rebar Check = "OK" 352 Vertical Rebar calculation Minimum vertical rebar for wall, (Refer cH#14.3.2) Ag, y agg = 0.002 1000 mm Width Age gag = 120mm? Uso 15M @ 300 cic verteal rebar on each face of the wal, Tal vertical Rebar Provided, Ag y pry = $22 ays? Act V_prov = 1333.33 min? Vertical Rebar Check = if(Ace y prow S AstV_reqds"CHECK" "0K") Veatical_Rebar_ Check = "OK" 3:7 Anchor Bolt Checking for Ring Beam Dia of Anchor Bolt, djyg= 32mm Anchor Bot Spacing, Spacing = 3038 mm Projection = 425 mm Bolt Edge distance, Edge = 160 mm Check Edge = if(Edge <4 Upajy,"CHECK","OK") Check Edge = "OK" E hoot Maximum Tension on Anchor Bolt, Tygjy = 19.7KN Factor Tension, y= 1.5 Tyoje Tp= 29.55KN Ductile failure of anchor bolt is checked for ultimate capacity of anchor bolt Ultimate tension for each bolt, T,, = 165 kN Provide Embedment length of bolt, Lemb bolt = 600 mm MPA Tong = 709.85 KN Tension capacity of concrete beam, Tapge = (Width Lem pole 2) 0.3 one Conerete_capacitycheck = if(Teope 2 Ty." re S"CHECK") Concrete capacity ches Total Length of Bol Lyoit = Lami bote > Proiestiod gg = 1025 mnt

You might also like