el SPECIFICATION FORBEDD | = © "*sseietane AP horton DEMONSTRATION H2 PSA DOG.No. : A11226-PR-10 UNITAT VR Date of Issue : Oct 12, 2012 Rev.No: 4 Job No. : A11226 Page : 33 of 47 5.1.4.2. WORKING HOLDUPS Unit feed surge drum, upstream unit in same control room : 15 minutes Unit feed surge drum, upstream unit in separate control room : 15 minutes For fired heater feeds: 10 minutes For tower feecs. same control station : 8 minutes For tower feeds, remote control station : 12 minutes - For pumped rundown to storage / other unit surge drums : 3 minutes (min) - For gravity runcown to storage / other unit surge drum: 3 minutes - For tower reflux streams in distillate drums. : 5 minutes (this surge is add tive to surge for downstream tower feed or rundown) ~ Compressor suction KOD (based on 5 %wt of inlet vapor) : 3 minutes ~ Compressor intar-stage KOD (automated drain) : 3 minutes = Compressor inter-stage KOD (manual drain if <5m°): 8 -24 hours ~ Refrigeration in ermediate-surge drum : § minutes ~ Refrigeration accumulator : 15 minutes 5.1.4.3. ADDITIONAL HCILDUPS: - Additional surge, LOL to LLL, normal pumps : 2 minutes - Additional surge, LOL to LLL, large / high speed pumps : 3 minutes Additional surge, HOL to HHL, gas to fuel gas system : 2 minutes - Additional surge, HOL to HHL, gas to large compressors: 3 minutes - Additional surge, HOL to HHL, critical compressors : 5-10 minutes For horizontal vessels, the normal liquid level shall be fixed at 50% of the vessel diameter,