Professional Documents
Culture Documents
Original drawing
1065m
1027m
Problems
1. How many people is going to be suppulied by this system?
2. What amount of water is necessay for each Taps?
3. Were distribution pipes considered Peak Flow Rate(PFR)?
In the Hydrailic
chart, elevation
says
1065m,Why
1250?
T1
In the Hydrailic chart,
elevation says 1027m
,
Why 1239m?
T2
T4
T6
T7
T5
T3
Problems
Where did these
flow rates come
from?
PFR is not
considered
Sample of design
Estimation of flow rate and peak flow rate are important. The following chart
present a sample of it assuming that
(1) Water consumption per day per capita is 150L
(2) Peak factor of water consumption is 1.5 looking at increased demand in
the morning and evening.
This system
has no
reservoir. So,
peak flow rater
should be
taken
Systems from T2 to
T7 have reservoir.
So, flow rater should
be taken
Intake rate
PFR 0.53(L/s)
T1
Population 200
PFR 0.53(L/s)
Population 300
PFR 0.78(L/s)
Population 100
PFR 0.26(L/s)
T2
T4
Population 400
PFR 1.04(L/s)
T3
T6
T7
Population 400
PFR 1.04(L/s)
T5
Population 200
PFR 0.53(L/s)
Population 400
PFR 1.04(L/s)
T2
T4
T3
0.5
2
(L/s
)
0.3
5
(L/s
)
T5
T6
T7
0.53
(L/s)
0.1
7
(L/
s)
0.8
7
(L/
s)
0.6
9
(L/
s)
0.6
9
(L/
s)
0.6
9
(L/
s)
)
3.1
1
(L/
s)
Hydraulic gradient
line 1
P5
4
2.9
4
(L/
s)P6
2.0
7
(L/
P7
s)
Hydraulic gradient
line 2
Hydraulic gradient
line 3
1.3
8
(L/
s)
Hydraulic gradient
line 4
P8
5
P54
1027m
P62
P78
P85