Duty head

Design head
Pipe diameter U/s of header
Header diamter
Force in pipe

m
m
mm
mm
kN

100
100
800
1100
493.104383

Force in header

kN

932.275474

Soil above pipe


Soil density
Ws
Pipe thickness
Wp
Ww

m
kN/cubm
kN/m
mm
kN/m
kN/m

1
8.19
9.009
10
2.66461281
9.32275474

Soil height
Soil pressure at base
Coefficient of friction,
Kp
Ka

m
kN/sq.m
rad

Sliding Calculation
Passive pressure at block base
Active pressure at block base
Net passive pressure at block base
Total net force above block base
Point of application above base
Resisting forces
FOS

kN/sqm
kN/sqm
kN/sqm
kN
m
kN