You are on page 1of 2
-edara. [ SUBMITTAL TRANSMITTAL SHEET # =U eSIeTeL Project Name | Motorcity-Uptown Area-1-Buildings [28 | IE ep y Date 07/12/06 [Submittal No.: 00050-0001 Revision: [1 [Submittal Title: [PT Design Raft Low Rise Terrace Blocks ABC (Basement and Ground Floor) We are sending herewith under separate cover the drawings documents /sampies listed below: la |=!TEM=|DWGS-SPECS— ——————— = —= NO. | BOO REF. DESCRIPTION TYPE |COPIES| REMARK: 1 NA |File with design calculations and model] OT 3 [These will be lprintouts. forthe syed os 2 NA _|Design Drawings (44 No.) sD 3 Re ett design. 3 NA _|CD containing all the above oT 2 [TYPE SD= Shop Drawings, SWi= Sample, GT= Guarantee, MO= Manufacturers Data, CT= Cerifiates, 11= Test Results, OT= Ofer |Subcontractor/ Supplier/Manufacturer:|[ANLOR |We certify that the documents 7 materials submitted herewith have been reviewed Jconformance with the contract drawings and specifications except as otherwise st (Contractor Name: Liam Walsh — [Signature: |Al Naboodah Laing O’Rourke Date:07/12/06 Design Consultant Review Comments Leura - Nob [© Approved aPprRved refer to O Approved As Noted arkachad com 5 ‘G_Approved as No! mit Ree O-hetReauted eee eR = Submit Shop dvawinns atten ol Se | Design Consultant (Name): Signature Rev'd By’ (( 07 nec 05 |) A NO Ad Date: Date: Ler wo] edara Project Manager Comments D Approved © Approved As Noted Approved as Noted, Resubmit © Not Required Not Approved ledara PM (Name): [Signature: Jt. WZ e Rev'd By: Antone Heston,’ Date: 4-/(/o > Date: | corecions or com ya submate duing Wis rovew donot eave To Sonate fom compliance wih he raqurenons [tho Convact. Thien on-ft en of gonealconomnance with he design concept of he pejen a pence crepes Bel Internet a contlectdocinjens. ‘The conrecr fe responsble fr coring and earelaing al quares td Serensons| selec atc proceso ad Inchigote of consiucton, coocinsing his wok wth tof hr Wades snd performing is wor ne st Prrerirn Sheet _X_ of _X recon ahi 202, cud. Dito EbarIABHGHGH L1] consutant [Jos L] contactor E] omers ¥ Dye Project: Motor City — UPTown Area 1 - Buildings Attachment to Transmittal # 10222/2/STS/003 Submittal No.: 00050-0001 ‘Comments : Not approved for the followings: 1. The model seems to be incorrect because the model run log shows warning. (log file attached) __2. Properties for the pour strip is not assigned in the model, 3. Raft slab thickness is not properly assigned. 4. Concrete Strength Specification to be corrected as per actual to be used. 5. Modeling to be made as per the sequence of construction. 6. Specify the method of post tensioning to allow free movement of RAFT slab over Blinding concrete / base soil while applying tension. 7. Material specification of tendons and reinforcement to be same in specific and model 8. Third Party review report to be submitted along with next submission. 9. Design re-review pending the attendance to the above noted comments. 03 Jol lo}

You might also like