The minimum space bet

The corroision allowanc


Input Req

Input Req
Input Req
From table
From table

e minimum space between the bolts are 18 inches


e corroision allowance of the bolts are taken to be 1/8 inches

AB
Cb
M
W
Sb
N

Bolt circle diameter


Area with in the bolt circle
Circumference of the bolt circle
Moment at the base due to the wind or earthquake
Weigth of the tower during erection
Max. allowable of the bolt mat.
No. fo bolts

Maximum tension per Lb/lin in.=12M/Ab-W/Cb

Ba

Required Area fo oen botl Sq in =TCb/SbN


Adding 1/8 inches for the corrosion
From table A the root area of the bolt
Stress in the anchor bolt=TCb/(BaN)
As the stress should be less than the allowable stress

S
Check

3.175 mm

30 in
707.1429 sqin
94.28571 in
86400 ft-lb
6000 lb
15000 psi
4
1402.545 lb/lin. In.
2.204 sqin
2.329 sqin
2.3 sqin
14373.91 psi
The Bolt dia. is sufficeint