Professional Documents
Culture Documents
INSPECTION CERTIFICATE
PAGE: 1/3
3 2P14S036902
DATE: 2002-09-10
QUANTITY:258pcs.
Mn
S
*2
30
Cu
Ni
190
P
*2
30
25
Al
*2
-
*1 R:LADLE &
PRODUCT ANALYSIS
L:LADLE ANALYSIS
P:PRODUCT ANALYSIS
35
138
141
141
138
141
142
142
143
145
22
20
19
18
18
18
18
17
18
5
4
4
4
4
4
4
4
4
4
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
43
41
39
35
35
34
46
41
46
*2: X1000
OTHER:X100
TENSILE TEST
YS
*1 *2 *3
SPEC. MIN. H/T LOT L B
P 80.0
MAX. NO.
L B
P 95.0
HEAT NO.
J2K8335
001 L BT
P 88.6
007 L BT
P 86.6
J2K8338
002 L BE
P 87.9
003 L BT
P 86.4
004 L BE
P 87.7
006 L BE
P 81.8
J2K8340
005 L BT
P 86.3
TS
*3
P
P
95.0
-
EL
%
19.5
-
P
P
P
P
P
P
P
108.1
106.6
107.2
106.5
106.7
102.8
106.5
33.9
33.9
34.2
36.8
35.8
35.4
34.6
TYPE OF SPECIMEN
STRIP 1-1/2"(38mm)
WIDTH
GAUGE LENGTH
2.0"
KIND OF YS
0.5% EXTENSION
UNDER LOAD
*1 DIRECTION
L:LONGITUDINAL
*2 SAMPLING POSITION
B:BASE METAL
BT:BASE METAL(TOP)
BE:BASE METAL(BOTTOM)
*3 UNIT
P:ksi
SMI CERTIFY THAT THE MATERIAL HEREIN DESCRIBED HAS BEEN MANUFACTURED, SAMPLED, TESTED AND
INSPECTED IN ACCORDANCE WITH THE CONTRACT REQUIREMENTS AND IS FULLY IN COMPLIANCE.
William H.
Stevenson-BP-NIB
I have reviewed,
accepted and digitally
signed this document
on 25-09-02
Page 1 of 3
IN-SPEC
INSPECTION CERTIFICATE
PAGE: 2/3
DATE: 2002-09-10
IMPACT TEST
SPEC. MIN.
MAX.
MIN. H/T LOT
MAX. NO.
HEAT NO.
J2K8335
001
001
007
007
J2K8338
002
002
003
003
004
004
006
006
J2K8340
005
005
14.0F
*1 *2
L
B
L
B
L
B
L
B
L
L
L
L
L
L
L
L
L
L
L
L
L
L
BT
BT
BT
BT
BE
BE
BT
BT
BE
BE
BE
BE
BT
BT
2V
*3
E
E
S
S
E
S
E
S
E
S
E
S
E
S
E
S
E
S
10x10
*4
F
F
%
%
F
%
F
%
F
%
F
%
F
%
F
%
F
%
(1)
25
-
(2)
37
-
(3)
37
-
AVG.
37
-
100
100
108
100
112
100
126
100
125
100
98
94
127
100
84
100
100
100
108
100
117
100
125
100
85
90
119
100
100
100
105
100
120
100
119
100
128
100
93
95
122
100
95
100
104
100
113
100
121
100
126
100
92
93
123
100
*1 DIRECTION
L:LONGITUDINAL
*2 SAMPLING POSITION
B:BASE METAL
BT:BASE METAL(TOP)
BE:BASE METAL(BOTTOM)
*3 CONTENTS OF TEST
E:ABSORBED ENERGY
S:SHEAR AREA
*4 UNIT
F:ftlbf
%
THE FOLLOWING OPERATIONS HAVE BEEN CARRIED OUT ON THIS MATERIAL AND WHERE FOUND TO COMPLY WITH
THE CALL OFF AND CONTRACT REQUIREMENTS.
THE SPECIFIC REQUIREMENTS ARE DETAILED IN THE SPECIFICATION REFERRED TO ON PAGE 1 OF THIS
MILL CERTIFICATE.
1)
A) VISUAL AND DIMENSIONAL INSPECTION
B) VOLUMETRIC ULTRASONIC EXAMINATION FOR WALL THICKNESS, LONGITUDINAL AND TRANSVERSE
INDICATIONS.
C) MAGNETIC PARTICLE EXAMINATION OF PIPE END NOT COVERED BY ULTRASONIC EXAMINATION
D) FULL LENGTH MAGNETIC PARTICLE EXAMINATION OF PIPE BODY IF REQUIRED BY SPECIFICATION
E) ELECTROMAGNETIC EXAMINATION
F) RESIDUAL MAGNETISM
G) DRIFT TEST (IF DRIFT SIZE IS SPECIAL, THE SIZE IS REFERRED TO ABOVE)
H) HYDROSTATIC TEST
I) HARDNESS IF REQUIRED BY SPECIFICATION
2)
3) IF A VOCAB NUMBER IS APPLICABLE FOR THIS ITEM IT CAN BE FOUND EITHER ON PAGE 1 OF THIS
MILL CERTIFICATE OR
THE ASSOCIATED TALLY LIST
SMI CERTIFY THAT THE MATERIAL HEREIN DESCRIBED HAS BEEN MANUFACTURED, SAMPLED, TESTED AND
INSPECTED IN ACCORDANCE WITH THE CONTRACT REQUIREMENTS AND IS FULLY IN COMPLIANCE.
IN-SPEC
INSPECTION CERTIFICATE
PAGE: 3/3
DATE: 2002-09-10
HARDNESS TEST(HRC)
SPEC. MIN.
MAX.
- 23.0
MID WALL
V.A.
H/T
SAMPLING AVG. QUAD
OUTER WALL
INNER WALL
LOT
POSITION
-RANT IMPRESSION NO.
IMPRESSION NO.
IMPRESSION NO.
(1) (2) (3) AVG. (1) (2) (3) AVG. (1) (2) (3) AVG.
HEAT NO.
NO.
J2K8335
001
TOP 19.9
A 18.8 19.2 18.5 18.8 21.1 20.5 20.8 20.8 19.8 20.0 20.1 20.0 2.0
007
TOP 18.7
A 17.1 17.3 17.6 17.3 19.4 19.5 19.8 19.6 18.8 19.8 18.7 19.1 2.3
J2K8338
002 BOTTOM 19.1
A 17.9 18.1 17.1 17.7 20.1 19.7 20.2 20.0 20.0 19.8 19.3 19.7 2.3
003
TOP 18.8
A 18.0 18.2 18.6 18.3 19.2 19.5 19.9 19.5 19.0 18.6 18.1 18.6 1.2
004 BOTTOM 18.6
A 17.1 18.6 17.3 17.7 18.0 19.4 19.2 18.9 19.5 19.0 19.0 19.2 1.5
006 BOTTOM 17.6
A 15.9 16.4 16.9 16.4 18.4 18.9 18.9 18.7 17.5 18.0 17.2 17.6 2.3
J2K8340
005
TOP 18.9
A 18.0 18.6 18.0 18.2 19.5 19.3 19.6 19.5 18.9 18.8 19.6 19.1 1.3
ALL AVG. 18.8
V.A.:VARIATION AVERAGE MAX.-MIN.
SMI CERTIFY THAT THE MATERIAL HEREIN DESCRIBED HAS BEEN MANUFACTURED, SAMPLED, TESTED AND
INSPECTED IN ACCORDANCE WITH THE CONTRACT REQUIREMENTS AND IS FULLY IN COMPLIANCE.
IN-SPEC