You are on page 1of 2

Technical Data Sheet

FlexLine

Weitergabe an Dritte nur mit Genehmigung der Fa. LEONI Kabel GmbH & Co. KG - Alle Rechte vorbehalten Transfer to third party only by authority of LEONI Kabel GmbH & Co. KG
Formular: W1-WW-PT-TDBL2-A-20 DV-Werk1 2000

Super flexible cable S (PE)

Design
Inner conductor: copper-clad aluminium wire
Insulation of foamed Polyethylene (PE) with skin
Outer conductor: copper-tape (thickness 0.25 mm)
longitudinal welded.
Spiral corrugated

3.6 mm (0.142 in)


9.1 mm (0.358 in)
(12.3 0.15) mm (0.484 0.006 in)

Jacket:
Polyethylene (PE) BK
Wall thickness about 0.6 mm (0.024 in)
Printing: LEONI L * FlexLine 1/2" S 50
+ marking every meter
Electrical data at 20C
Inner conductor resistance
Outer conductor resistance
Insulation resistance
Capacitance (1 kHz)
Characteristic Impedance
Relative velocity of propagation
Test voltage (wire/screen rms 50Hz 1min)
HF-operating voltage (peak)
Return loss 400 - 500 MHz
800 - 1000 MHz
1700 - 2700 MHz

(13.5 0.2) mm (0.531 0.008 in)


" internal order number " "month/year"

3.0
3.4
10
80
(50 1)
82
2000
1000

26

26

26

Ohm/km
Ohm/km
GOhm*km
nF/km
Ohm
%
V
V
dB
dB
dB

(0.92 Ohm/1000ft)
(1.04 Ohm/1000ft)
(32.8 GOhm*1000ft)
(24.4 nF/1000ft)

(VSWR 1.1)
(VSWR 1.1)
(VSWR 1.1)

P.O. Box 8817, Lake Charles, LA 70606, Ph. 866.598.5250 Fax:337.598.5290 e-mail: rlss@rlss.us Web: www.rlss.us
Page 1 of 2

Technical Data Sheet

Weitergabe an Dritte nur mit Genehmigung der Fa. LEONI Kabel GmbH & Co. KG - Alle Rechte vorbehalten Transfer to third party only by authority of LEONI Kabel GmbH & Co. KG
Formular: W1-WW-PT-TDBL2-A-20 DV-Werk1 2000

Screening attenuation
Passive intermodulation
Inductance
Max. operating frequency
Cut-off frequency
Max. peak power
Attenuation

120
160
0.195
10.2
13
19

dB
dBc
H/m (0.059 H/ft)
GHz
GHz
kW
s. table

Frequency (MHz)

100

450

800

900

1000 1800 1900 2200 2500 2700 3000

Attenuation typ. (dB/100m)


(dB/100ft)

3
(0,9)

6,8
(2,1)

9,3
(2,8)

9,9
(3,0)

10,5
(3,2)

14,6
(4,4)

15
(4,6)

16,3
(5,0)

17,6
(5,4)

18,4
(5,6)

19,5
(5,9)

Mean. Power (kW)


at 40C (104F)

2.6

1.2

0.87

0.81

0.77

0.55

0.54

0.49

0.46

0.44

0.41

Mechanical and thermal characteristics


Jacket material acc. to DIN EN 50290-2-24 (VDE 0819), table 1/2-L/MD (HD 624.4)
Screen material acc. to DIN EN 13602 Cu-ETP-R
Other characteristics:
Corrosivity of fire gases acc. to IEC 60754-2
Permissible temperature range, installation
Permissible temperature range, operation
Min. bending radius allowed
Number of bends. minimum (typical)
Tensile strength
Weight about

: -40 C (-40 F) up to +60 C (+140 F)


: -55C (-67F) up to +85C (+185F)
: repeated 2,15X , single 1,1X
: 20 (50)
: 700 N
: 190 Kg/km (127,3 lb/1000ft)

Application/Special feature:
Coaxial cabling for application cellular phone
Designation of order:
V45466-B19-C56
202937
02YWK2Y 3.6/9.1-50 ALCU
500 m (1640 ft) on non-returnable reel

P.O. Box 8817, Lake Charles, LA 70606, Ph. 866.598.5250 Fax:337.598.5290 e-mail: rlss@rlss.us Web: www.rlss.us
Page 2 of 2