Professional Documents
Culture Documents
Canopy 2
Canopy 2
www.hilti.in
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
Benchmark Consultants
Mr. Vaibhav
Amedabad
|
Page:
Project:
Sub-Project I Pos. No.:
Date:
1
GSRTC
Subhash Bridge
10/08/2015
1 Input data
Anchor type and diameter:
Material:
5.8
ETA 12/0084
Issued I Valid:
15/04/2015 | 15/04/2020
Proof:
Design method SOFA design method + fib (07/2011) - after ETAG BOND testing
Stand-off installation:
eb = 0 mm (no stand-off); t = 16 mm
Anchor plate:
Profile:
no profile
Base material:
uncracked concrete, C20/25, fc = 20.00 N/mm2; h = 450 mm, Temp. short/long: 40/24 C
Installation:
Reinforcement:
no reinforcement or reinforcement spacing >= 150 mm (any ) or >= 100 mm ( <= 10 mm)
no longitudinal edge reinforcement
Reinforcement to control splitting according to
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in
Page:
Project:
Sub-Project I Pos. No.:
Date:
Benchmark Consultants
Mr. Vaibhav
Amedabad
|
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
2
GSRTC
Subhash Bridge
10/08/2015
3
Shear force y
0.000
0.000
0.000
0.000
x
Compression
Tension
Capacity [kN]
82.000
Utilization bN [%]
27
Status
OK
44.041
172.139
26
OK
44.041
102.568
43
OK
44.041
146.272
31
OK
Steel Strength*
Splitting failure**
* anchor having the highest loading
gM,s
1.500
NRd,s [kN]
82.000
NSd [kN]
22.021
A0p,N [mm2]
384000
yA,Np
1.022
2
tRk,ucr,25 [N/mm ]
18.00
scr,Np [mm]
620
yc
1.000
2
tRk,ucr [N/mm ]
18.00
yg,Np
1.000
yg,Np
1.000
ec1,N [mm]
0
yec1,Np
1.000
ec2,N [mm]
0
yec2,Np
1.000
ys,Np
0.894
N0Rk,p [kN]
282.743
NRk,p [kN]
258.208
gM,p
1.500
NRd,p [kN]
172.139
NSd [kN]
44.041
ccr,Np [mm]
310
cmin [mm]
200
yre,Np
1.000
A0c,N [mm2]
562500
yA,N
0.920
ccr,N [mm]
375
scr,N [mm]
750
ec1,N [mm]
0
yec1,N
1.000
ec2,N [mm]
0
yec2,N
1.000
ys,N
0.860
yre,N
1.000
N0Rk,c [kN]
194.454
gM,c
1.500
NRd,c [kN]
102.568
NSd [kN]
44.041
Ac,N [mm2]
448200
A0c,N [mm2]
462400
yA,N
0.969
ccr,sp [mm]
340
scr,sp [mm]
680
yh,sp
1.328
ec1,N [mm]
0
yec1,N
1.000
ec2,N [mm]
0
yec2,N
1.000
ys,N
0.876
yre,N
1.000
N0Rk,c [kN]
194.454
gM,sp
1.500
NRd,sp [kN]
146.272
NSd [kN]
44.041
k1
11.000
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
k1
11.000
www.hilti.in
Page:
Project:
Sub-Project I Pos. No.:
Date:
Benchmark Consultants
Mr. Vaibhav
Amedabad
|
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
3
GSRTC
Subhash Bridge
10/08/2015
Capacity [kN]
48.800
Utilization bV [%]
31
Status
OK
N/A
N/A
N/A
N/A
Pryout Strength**
60.000
214.055
29
OK
30.000
47.522
64
OK
gM,s
1.250
VRd,s [kN]
48.800
VSd [kN]
15.000
A0c,N [mm2]
562500
yA,N
0.960
ccr,N [mm]
375
scr,N [mm]
750
k4
2.000
ec1,V [mm]
0
yec1,N
1.000
ec2,V [mm]
0
yec2,N
1.000
ys,N
0.860
yre,N
1.000
N0Rk,c [kN]
194.454
gM,c,p
1.500
VRd,c1 [kN]
214.055
VSd [kN]
60.000
dnom [mm]
20.0
kV
2.400
a
0.077
c1 [mm]
400
Ac,V [mm2]
607500
A0c,V [mm2]
720000
yA,V
0.844
ys,V
1.000
yh,V
1.155
ya,V
1.000
ec,V [mm]
0
yec,V
1.000
V0Rk,c [kN]
146.330
n1
2
gM,c
1.500
VRd,c [kN]
47.522
VSd [kN]
30.000
b
0.055
yre,V
1.000
y90,V
2.000
5 Combined tension and shear loads SOFA (fib (07/2011), section 10.3)
steel
bN
0.269
bV
0.307
a
2.000
Status
OK
concrete
0.429
0.631
1.500
79
OK
bN + bV <= 1
16.311 [kN]
dN
0.062 [mm]
VSk
11.111 [kN]
dV
0.444 [mm]
dNV
0.449 [mm]
16.311 [kN]
dN
0.104 [mm]
VSk
11.111 [kN]
dV
0.667 [mm]
dNV
0.675 [mm]
Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!
The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
Benchmark Consultants
Mr. Vaibhav
Amedabad
|
Page:
Project:
Sub-Project I Pos. No.:
Date:
4
GSRTC
Subhash Bridge
10/08/2015
7 Warnings
Load re-distributions on the anchors due to elastic deformations of the anchor plate are not considered. The anchor plate is assumed to be
sufficiently stiff, in order not to be deformed when subjected to the loading!
Input data and results must be checked for agreement with the
existing conditions and for plausibility!
The design method ETAG (filled holes) assumes that no hole clearance between the anchors and the fixture is present. This can
be
achieved by filling the gap with mortar of sufficient compressive strength (e.g. by using the Hilti Dynamic Set) or by other suitable means
The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
Bore hole cleaning must be performed according to instructions for use (blow twice with oil-free compressed air (min. 6 bar), brush twice,
blow twice with oil-free compressed air (min. 6 bar)).
Characteristic bond resistances depend on short- and long-term temperatures.
Please contact Hilti to check feasibility of HIT-V rod supply.
The design method fib (07/2011) assumes that no hole clearance between the anchors and the fixture is present. This can be achieved by
filling the gap with mortar of sufficient sompressive strength (e.g. by using the Hilti Dynamic Set) or by other suitable means.
The compliance with current standards (e.g. EC3) is the responsibility of the user
Checking the transfer of loads into the base material is required in accordance with fib (07/2011)!
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in
5
GSRTC
Subhash Bridge
10/08/2015
Page:
Project:
Sub-Project I Pos. No.:
Date:
Benchmark Consultants
Mr. Vaibhav
Amedabad
|
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
8 Installation data
Anchor plate, steel: Profile: no profile
Hole diameter in the fixture: df = 22 mm
Plate thickness (input): 16 mm
Recommended plate thickness: not calculated
Cleaning: Premium cleaning of the drilled hole is required
Cleaning
Compressed air with required
accessories to blow from the bottom of
the hole
Proper diameter wire brush
y
150
50
150
Setting
Dispenser including cassette and mixer
Dynamic set
Torque wrench
150
125
125
50
50
200
x
-100
100
-100
100
y
-75
-75
75
75
c-x
200
400
200
400
c+x
400
200
400
200
c-y
-
c+y
-
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
50
www.hilti.in
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
Benchmark Consultants
Mr. Vaibhav
Amedabad
|
Page:
Project:
Sub-Project I Pos. No.:
Date:
6
GSRTC
Subhash Bridge
10/08/2015
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan