You are on page 1of 8

Changing the Protection Mode from Maximum Protection

to Maximum Availability
Changing protection mode and 'LogXptMode' for Physical
Standby DB (affect spfile of Primary)

DGMGRL> show database verbose 'PEMDEVSTBY';


Database - PEMDEVSTBY
Role:
PHYSICAL STANDBY
Intended State:
APPLY-ON
Transport Lag:
0 seconds (computed 1 second ago)
Apply Lag:
0 seconds (computed 1 second ago)
Average Apply Rate: 2.00 KByte/s
Active Apply Rate: 774.00 KByte/s
Maximum Apply Rate: 1.38 MByte/s
Real Time Query: ON
Instance(s):
PEMDEVSTBY
Properties:
DGConnectIdentifier
= '(DESCRIPTION=(ADDRESS=(PROTOCOL=tcp)
(HOST=eunloo12c)(PORT=1521))(CONNECT_DATA=(SERVICE_NAME=PEMDEVSTBY)
(SERVER=DEDICATED)))'
ObserverConnectIdentifier
= ''
LogXptMode
= 'ASYNC'
RedoRoutes
= ''
DelayMins
= '0'
Binding
= 'optional'
MaxFailure
= '0'
MaxConnections
= '1'
ReopenSecs
= '300'
NetTimeout
= '30'
RedoCompression
= 'DISABLE'
LogShipping
= 'ON'
PreferredApplyInstance
= ''
ApplyInstanceTimeout
= '0'
ApplyLagThreshold
= '0'
TransportLagThreshold
= '0'
TransportDisconnectedThreshold = '30'
ApplyParallel
= 'AUTO'
StandbyFileManagement
= 'AUTO'
ArchiveLagTarget
= '0'
LogArchiveMaxProcesses
= '4'

LogArchiveMinSucceedDest
= '1'
DbFileNameConvert
= '/ora-data/oradata/PEMDEV/sysdata, /oradata/oradata/PEMDEV_STBY'
LogFileNameConvert
= '/ora-data/oradata/PEMDEV/redolog, /oradata/oradata/PEMDEV_STBY'
FastStartFailoverTarget
= ''
InconsistentProperties
= '(monitor)'
InconsistentLogXptProps
= '(monitor)'
SendQEntries
= '(monitor)'
LogXptStatus
= '(monitor)'
RecvQEntries
= '(monitor)'
StaticConnectIdentifier
= '(DESCRIPTION=(ADDRESS=(PROTOCOL=tcp)
(HOST=EUNLOO12c)(PORT=1521))
(CONNECT_DATA=(SERVICE_NAME=PEMDEVSTBY_DGMGRL)
(INSTANCE_NAME=PEMDEVSTBY)(SERVER=DEDICATED)))'
StandbyArchiveLocation
= 'USE_DB_RECOVERY_FILE_DEST'
AlternateLocation
= ''
LogArchiveTrace
= '0'
LogArchiveFormat
= 'c%t_%s_%r.dbf'
TopWaitEvents
= '(monitor)'
Database Status:
SUCCESS
DGMGRL> edit database 'PEMDEVSTBY' SET PROPERTY 'LogXptMode' = 'SYNC';
Property "LogXptMode" updated
Changing the Protection Mode
DGMGRL> EDIT CONFIGURATION SET PROTECTION MODE AS MaxAvailability;
Succeeded.
DGMGRL> show database verbose 'PEMDEVSTBY';
Database - PEMDEVSTBY
Role:
PHYSICAL STANDBY
Intended State:
APPLY-ON
Transport Lag:
0 seconds (computed 0 seconds ago)
Apply Lag:
0 seconds (computed 0 seconds ago)
Average Apply Rate: 2.00 KByte/s
Active Apply Rate: 717.00 KByte/s
Maximum Apply Rate: 1.38 MByte/s
Real Time Query: ON
Instance(s):
PEMDEVSTBY

Properties:
DGConnectIdentifier
= '(DESCRIPTION=(ADDRESS=(PROTOCOL=tcp)
(HOST=eunloo12c)(PORT=1521))(CONNECT_DATA=(SERVICE_NAME=PEMDEVSTBY)
(SERVER=DEDICATED)))'
ObserverConnectIdentifier
= ''
LogXptMode
= 'SYNC'
RedoRoutes
= ''
DelayMins
= '0'
Binding
= 'optional'
MaxFailure
= '0'
MaxConnections
= '1'
ReopenSecs
= '300'
NetTimeout
= '30'
RedoCompression
= 'DISABLE'
LogShipping
= 'ON'
PreferredApplyInstance
= ''
ApplyInstanceTimeout
= '0'
ApplyLagThreshold
= '0'
TransportLagThreshold
= '0'
TransportDisconnectedThreshold = '30'
ApplyParallel
= 'AUTO'
StandbyFileManagement
= 'AUTO'
ArchiveLagTarget
= '0'
LogArchiveMaxProcesses
= '4'
LogArchiveMinSucceedDest
= '1'
DbFileNameConvert
= '/ora-data/oradata/PEMDEV/sysdata, /oradata/oradata/PEMDEV_STBY'
LogFileNameConvert
= '/ora-data/oradata/PEMDEV/redolog, /oradata/oradata/PEMDEV_STBY'
FastStartFailoverTarget
= ''
InconsistentProperties
= '(monitor)'
InconsistentLogXptProps
= '(monitor)'
SendQEntries
= '(monitor)'
LogXptStatus
= '(monitor)'
RecvQEntries
= '(monitor)'
StaticConnectIdentifier
= '(DESCRIPTION=(ADDRESS=(PROTOCOL=tcp)
(HOST=EUNLOO12c)(PORT=1521))
(CONNECT_DATA=(SERVICE_NAME=PEMDEVSTBY_DGMGRL)
(INSTANCE_NAME=PEMDEVSTBY)(SERVER=DEDICATED)))'
StandbyArchiveLocation
= 'USE_DB_RECOVERY_FILE_DEST'
AlternateLocation
= ''
LogArchiveTrace
= '0'
LogArchiveFormat
= 'c%t_%s_%r.dbf'
TopWaitEvents
= '(monitor)'
Database Status:
SUCCESS
DGMGRL> show configuration;

Configuration - PEMDEV
Protection Mode: MaxAvailability
Members:
PEMDEV
- Primary database
PEMDEVSTBY - Physical standby database
Fast-Start Failover: DISABLED
Configuration Status:
SUCCESS (status updated 33 seconds ago)
DGMGRL>
DGMGRL> show database verbose 'PEMDEV';
Database - PEMDEV
Role:
PRIMARY
Intended State:
TRANSPORT-ON
Instance(s):
PEMDEV
Properties:
DGConnectIdentifier
= '(DESCRIPTION=(ADDRESS=(PROTOCOL=tcp)
(HOST=eunloo12c)(PORT=1521))(CONNECT_DATA=(SERVICE_NAME=PEMDEV)
(SERVER=DEDICATED)))'
ObserverConnectIdentifier
= ''
LogXptMode
= 'ASYNC'
RedoRoutes
= ''
DelayMins
= '0'
Binding
= 'optional'
MaxFailure
= '0'
MaxConnections
= '1'
ReopenSecs
= '300'
NetTimeout
= '30'
RedoCompression
= 'DISABLE'
LogShipping
= 'ON'
PreferredApplyInstance
= ''
ApplyInstanceTimeout
= '0'
ApplyLagThreshold
= '0'
TransportLagThreshold
= '0'
TransportDisconnectedThreshold = '30'
ApplyParallel
= 'AUTO'
StandbyFileManagement
= 'AUTO'
ArchiveLagTarget
= '0'
LogArchiveMaxProcesses
= '4'
LogArchiveMinSucceedDest
= '1'

DbFileNameConvert
= ''
LogFileNameConvert
= ''
FastStartFailoverTarget
= ''
InconsistentProperties
= '(monitor)'
InconsistentLogXptProps
= '(monitor)'
SendQEntries
= '(monitor)'
LogXptStatus
= '(monitor)'
RecvQEntries
= '(monitor)'
StaticConnectIdentifier
= '(DESCRIPTION=(ADDRESS=(PROTOCOL=tcp)
(HOST=EUNLOO12c)(PORT=1521))
(CONNECT_DATA=(SERVICE_NAME=PEMDEV_DGMGRL)(INSTANCE_NAME=PEMDEV)
(SERVER=DEDICATED)))'
StandbyArchiveLocation
= '/ora-arch/PEMDEV/archivelog'
AlternateLocation
= ''
LogArchiveTrace
= '0'
LogArchiveFormat
= '%t_%s_%r.dbf'
TopWaitEvents
= '(monitor)'
Database Status:
SUCCESS

Tried to Modify the LogXptMode from SYNC to ASYNC


when the database in Maximum Availabilty Mode.

DGMGRL> edit database 'PEMDEVSTBY' SET PROPERTY 'LogXptMode' = 'ASYNC';


Error: ORA-16900: change of LogXptMode or RedoRoutes property violates overall
protection mode

Modified the LogXptMode from ASYNC to SYNC for the


Primary DB ( affect spfile of Physical Standby)
DGMGRL> show database verbose 'PEMDEV';
Database - PEMDEV
Role:
PRIMARY
Intended State:
TRANSPORT-ON
Instance(s):
PEMDEV
Properties:
DGConnectIdentifier
= '(DESCRIPTION=(ADDRESS=(PROTOCOL=tcp)
(HOST=eunloo12c)(PORT=1521))(CONNECT_DATA=(SERVICE_NAME=PEMDEV)
(SERVER=DEDICATED)))'
ObserverConnectIdentifier
= ''
LogXptMode
= 'ASYNC'
RedoRoutes
= ''
DelayMins
= '0'
Binding
= 'optional'
MaxFailure
= '0'
MaxConnections
= '1'
ReopenSecs
= '300'
NetTimeout
= '30'
RedoCompression
= 'DISABLE'
LogShipping
= 'ON'
PreferredApplyInstance
= ''
ApplyInstanceTimeout
= '0'
ApplyLagThreshold
= '0'
TransportLagThreshold
= '0'
TransportDisconnectedThreshold = '30'
ApplyParallel
= 'AUTO'
StandbyFileManagement
= 'AUTO'
ArchiveLagTarget
= '0'
LogArchiveMaxProcesses
= '4'
LogArchiveMinSucceedDest
= '1'
DbFileNameConvert
= ''
LogFileNameConvert
= ''
FastStartFailoverTarget
= ''
InconsistentProperties
= '(monitor)'
InconsistentLogXptProps
= '(monitor)'
SendQEntries
= '(monitor)'
LogXptStatus
= '(monitor)'
RecvQEntries
= '(monitor)'

StaticConnectIdentifier
= '(DESCRIPTION=(ADDRESS=(PROTOCOL=tcp)
(HOST=EUNLOO12c)(PORT=1521))
(CONNECT_DATA=(SERVICE_NAME=PEMDEV_DGMGRL)(INSTANCE_NAME=PEMDEV)
(SERVER=DEDICATED)))'
StandbyArchiveLocation
= '/ora-arch/PEMDEV/archivelog'
AlternateLocation
= ''
LogArchiveTrace
= '0'
LogArchiveFormat
= '%t_%s_%r.dbf'
TopWaitEvents
= '(monitor)'
Database Status:
SUCCESS
DGMGRL> edit database 'PEMDEV' SET PROPERTY 'LogXptMode' = 'SYNC';
Property "LogXptMode" updated

DGMGRL> show database verbose 'PEMDEV';


Database - PEMDEV
Role:
PRIMARY
Intended State:
TRANSPORT-ON
Instance(s):
PEMDEV
Properties:
DGConnectIdentifier
= '(DESCRIPTION=(ADDRESS=(PROTOCOL=tcp)
(HOST=eunloo12c)(PORT=1521))(CONNECT_DATA=(SERVICE_NAME=PEMDEV)
(SERVER=DEDICATED)))'
ObserverConnectIdentifier
= ''
LogXptMode
= 'SYNC'
RedoRoutes
= ''
DelayMins
= '0'
Binding
= 'optional'
MaxFailure
= '0'
MaxConnections
= '1'
ReopenSecs
= '300'
NetTimeout
= '30'
RedoCompression
= 'DISABLE'
LogShipping
= 'ON'
PreferredApplyInstance
= ''
ApplyInstanceTimeout
= '0'
ApplyLagThreshold
= '0'
TransportLagThreshold
= '0'
TransportDisconnectedThreshold = '30'

ApplyParallel
= 'AUTO'
StandbyFileManagement
= 'AUTO'
ArchiveLagTarget
= '0'
LogArchiveMaxProcesses
= '4'
LogArchiveMinSucceedDest
= '1'
DbFileNameConvert
= ''
LogFileNameConvert
= ''
FastStartFailoverTarget
= ''
InconsistentProperties
= '(monitor)'
InconsistentLogXptProps
= '(monitor)'
SendQEntries
= '(monitor)'
LogXptStatus
= '(monitor)'
RecvQEntries
= '(monitor)'
StaticConnectIdentifier
= '(DESCRIPTION=(ADDRESS=(PROTOCOL=tcp)
(HOST=EUNLOO12c)(PORT=1521))
(CONNECT_DATA=(SERVICE_NAME=PEMDEV_DGMGRL)(INSTANCE_NAME=PEMDEV)
(SERVER=DEDICATED)))'
StandbyArchiveLocation
= '/ora-arch/PEMDEV/archivelog'
AlternateLocation
= ''
LogArchiveTrace
= '0'
LogArchiveFormat
= '%t_%s_%r.dbf'
TopWaitEvents
= '(monitor)'
Database Status:
SUCCESS