1 +, 1 +

01 ' 5

The Right to Information, The Right to Live

Step Out From the Old to the New

Mazdoor Kisan Shakti Sangathan

Jawaharlal Nehru

IS 207 (1964): Gate and Shutter Hooks and Eyes [PGD 31:
Bolts, Nuts and Fasteners Accessories]

! $ ' +-
Satyanarayan Gangaram Pitroda

Invent a New India Using Knowledge

! > 0 B

BharthariNtiatakam

Knowledge is such a treasure which cannot be stolen

Indian Standard

IS : 207 - 1964
(Reaffirmed 2001)

P*-* lg8*
)

SPECIFICATION FOR GATE AND


SHUTTER HOOKS AND EYES

(Revised)
Fourth Reprint OCTOBER

UDC

683.352:621.885

@ Cqyi<&
BUREAU
MANAK

OF
BHAVAN,

INDIAN
9 BAHADUR

NEW

Gr 3

1988

DELHI

1964
STANDARDS
SHAH

ZAFAR

MARG

110002

May

1964

Indian Standard
SPECIFICATION FOR GATE AND
SHUTTER HOOKS AND EYES

(Revised 1
Builders

Hardware

Sectional

Chairman
SHBX Yooeur

Committee,

BDC

15

Rcpruenting
Y. C. Mowjee & Co., C8lOutt8

M~WJEE

Members
SHBI SAHIBSINOH
(,#hmata
Shri Youeuf Mowjee )
SHBI 8. BALAKBI~HNAN
SHUL A. IL BHIMANI

to
Engineer-in-Chief% Branoh. Army Hesdquartera
The Vertex Menufscturing Co. Private Ltd.,
Bombay
)
Indian Aluminium Co. Ltd., Caloutta

SE= H. C. SAMPAT ( A&w&e


R. K. CHABI
SBBI N. Q~PALBBIBHNAw
(&em&)
Railway
CORTBOLLBB
oY STOBE (EAT-

Sau

BBlVuILWAY)
8HU R.L. &HLOTlI
8lSBI HAlWAM&NOH

SHBI C. 8. RAO ( AZmte


)
SJKBIJ. P. JAM
SHBI K. P. JAIN ( AiXewmte)
SHBI K. P. JAIN
SBBXM.
L. YAKADIA
SEBI AJOY~~NDUPAUL
SHBI B. PBAT~

Board ( Mmietry of Railways )

Indian Inetitute of Architects. Bombay


Directorate Q8nerel of Suppliee & Disposle
Indien Hardwen, Induetriee Ltd., New Delhi

Engineering Aeeociation of Indie. C8loutta


Jay8nt Met81 I&mfaoturing Co., Bomb8y
Oobindo Sheet Metel Worlca & Foundry, Calcutta
National Buildings Orgenit38tion (Ministry
of
Worke. Housing & Rehsbilitstion )
Governnmnt Teet House, cShtt8
SXXBIE. K. RAXCE~DBAN
Builders Hardware
Industries Aviation
of
SHBI B. D. SVB~KA
Indie. C8lOuttS
SVBVBYOB O~WOBK~ VI (ZONE I) Centrcrl Publio Works Department
(Con%sedonpogrt)

BUREAU
MANAK

OF
BHAVAN,

INDIAN

STANDARDS

9 BAHADUR
SHAH
NEW DELHI 110002

ZAFAR

MARG

is:207-1964
(

amt~nueii
ffom page 1)
Rqmaenting

MembaTi?

Dsfence Production Organiurtion


Defellce )
Director.BIS ( &-0$260 ddcmbr)

SEEI B. C. THADANI
Da H. C. VIEWEWABAYA.
Deputy Dire&or ( Bldg )

SHBI 0. P.

P~HABMA

Extra Aasi&ant Dire&or

Wire Products

of

(Mini8try

( Bldg ), BIS

Subcommittee,

BDC 15 : 2

uonamwt
Queet, Kee~n,Willieme, Ltd., bloutk

MB. R. A. BIXNE
Mh?BtbW8

SEBI 8. K. M~xar ( AUc*nots


Mr. R. A. Binna )
ABEIWEAWZ DIBEOTOB ( 8 6 R )
RIFBBABOH.Dmmtm & STAND-

to
Reilwey Baird ( Yirtry

of Reilweye )

ABDI3 tbUNIXATION

The Indian
Steel & Wire
Produota Ltd.,
Jemshedpur
SEBI R. R. K~~stlea ( &tern& )
The Sorew Msnufeoturera Aeeocietion, Celcntte
SEBI IHDBB MOHAN SAXEUJA
Directmute Uenerel of Suppliy &. Din-la
a&r z d S3JUIM
De~G~_~roduotiOn
Orgamrsbtion ( Miniby of
. .

SEBI HABUIAND

Smm

SRIU D. V. VIBMANI

Univerurl Sorea FIotory, C!hhehsrb ( Amritur

iS:207-1964

Indian Standard
SPECIFICATION FOR GATE AND
SHUTTER HOOKS AND EYES

( Revised)
0. FOREWORD
0.1 This revised Indian Standard was adopted by the Indian Standards
Institution on 10 March 1964, after the draft finalized by the Builders
Hardware Sectional Committee had been approved by the Building
Division Council.
0.2 This standard was first issued in 1950 specifying the various dimensions and other requirements of hooks and eyes in fps system. In view
of the adoption of the metric system of weights and measures by the
Government of India, the need for revision of this standard with a view
to metricizing it and bringing it in line with IS : 451-1961 Specification
for Wood Screws ( Revised) in regard to form of screw thread and other
relevant requirements has long been felt both by the trade and consumers.
This revision, therefore, specifies the various demensions and other
requirements of hooks and eyes made of mild steel and brass in the
metric units and the details of screw threads and other relevant requirements in accordance with IS : 451-1961.
0.3 The Sectional Committee responsible for the preparation of this
standard has taken into consideration the views of producers, consumers
and technologists and has related the standard to the manufacturing and
trade practices followed in the country in this field. Due weightage has
also been given to the need for international
co-ordination
among
standards prevailing in different countries of the world.
0.4 Wherever a reference to any Indian Standard
appears in
specification, it shall be taken as a reference to its latest version.

this

0.5 For the purpose of deciding whether a particular requirement of this


standard is complied with, the final value, observed or calculated, expressing the result of a test or analysis, shall be rounded off in accordance
with IS : 2-1960 Rules for Rounding Off Numerical. Values ( Revised ) .
3

IS:207-1964
The number of significant places retained in the rounded off value
should be the same as that of the specified value in this standard.
0.6 This standard is intended chiefly to cover the technical provisions
relating to gate and shutter hooks and eyes, and it does not cover all the
necessary provisions of a contract.
1. SCOPE
I.1 This standard lays down the requirements for gate and shutter hooks
and eyes which are commonly used on doors and windows for keeping
them in position when kept open.
2. TYPES
2.1 Nooks and eyes shall be of the following types:
Mild steel and hard-drawn brass hooks and eyes (see Fig. 1 ),
and
Type z--Cast
brass hooks and plates (see Fig. 2).

Type l-

3. SIZES
3.1 The standard
follows:

sizes of gate and shutter hooks and eyes shall be as

Type of Hook
and Eye

Type 1
Type 2

Nominal Size
65, 75, 100, 125, 150, 200,
250 and 300 mm
75, 100, 125, 150 and 200 mm

3.2 Gate and shutter hooks and eyes of sizes other than those specified
under 3.1 may be supplied by mutual agreement between the purchaser
and the su plier but the provisions laid down in this standard shall be
general+. fo; lowed.
4. MATERIAL
4.1 Mild Steel Wire -Mild
steel wire used in the manufacture of mild
steel hooks and eyes shall conform to IS : 1812-1961 Specification for
Mild Steel Wire for Manufacture of Wood Screws.
4.2 Brass Wire
4.2.1 Brass wire used in the manufacture of brass hooks and eyes,
when tested in accordance with*IS : 441-1955 Methods for Chemical
Since wirhdrawn.

Is:207-1964
nalysis of Brasses
bmposition:

and

Bronzes,

shall have

the following chemical

Percent

Constituent

60 to 72

Copper
Zinc

28 to 40

Tin, MUX

0.05

Iron, Max
Lead, Max

0.1
0.1

Total impurities including


tin, iron, lead, etc, Max

0.8

4.2.2 Brass wire shall have a minimum ultimate tensile strength of


12.5 kg/mm2 and a minimum elongation at break of 15 percent, when
tested in accordance withIS : 497-1953 Specification for Tensile Testing
of Metals ( Non-ferrous ).
brass used in the manufacture of cast type hooks
4.3 Cast Brass -Cast
shall conform to Grade 3 of IS : 292-1961 Specification for Brass Ingots
and Castings ( Revised ),
5. MANUFACTURE
5.1 Hooks, eyes and plates shall be well-made and free from defects.
They shall be finished to the correct shape and dimensions so as to function properly when they are in use. Cast hooks and plates shall be free
from casting and other defects.
5.2 The screw thread and the gimlet point of hooks and eyes shall
conform to the requirements laid down in IS: 451-1961 Specification for
Wood Screws ( Revised).
6. DIMENSIONS

AND TOLERANCES

6.1 The leading dimensions of hooks, eyes and plates, and tolerances
thereon shall conform to Tables I and II.
7. FINISH
7.1 Unless otherwise specified, the articles shall be finished bright.
8. INSPECTION

8.1 The purchaser

or his representative shall, if desired, be granted


facilities for inspection of finished goods prior to delivery.
*Since withdrawn.

..

TABL8 I

DIMENSIONS OF MILD ST%&L AND BRASS GA=


(

8zn

APP-

O&wut~6.1 and Fig. 1 )

a
APP-

D*
--Du$$io*

.
mm

mm

06

m*2

76

76 f

100

mm

AND SHUTTER HOOKS AND EYES

mm

&

Din of
Unthreaded

(o++l*5)

Ir
Appror

8harIk
mm

mm

mm

mm

10

4.17

6.7

14%

2-2

11

10

4-62

6-O

16.0

2.4

lQOf2

13

12

11

693

6.7

17.6

2.3

126

126f2

16

14

12

6-6Q

71

13.6

30

160

160 f

16

14

12

P6Q

7-l

13-6

3-O

200

zoo*2

18

14

14

6-30

I.8

2@6

3.4

260

26Of2

17

I6

I4

630

7-8

20-I

3.4

300

300*3

17

16

Ill

701

3.6

23-o

3-7

ti

..

*&raw deeignetion No. end die of unthreaded ahank conform to thorn given in IS
for wood Barewe ( Rsoised ).

: 461-1981 Speai5cation

Y
f

Fro.2 CAST BBAM

TABLE

II

DIMENSIONS

Hooxa

OF CAST

AND

BRASS

PLATIBI

HOOKS AND PLATES

( Clatme 6.1 and Fig. 2)


LJIZE

( AVE~AOE )

RI

SCBICW

HOLE8
g:D
SCBEW
No.

mm

mm

mm

mm

mm

mm

mm

mm

mm

76
100
126
160
200

75f2
lOOf
12a*2
16Of2
2OOf2

30fl
36fl
40*1
40fl
46fl

20* 1
26fl
30fl
30&:!
36&I

4yl*o*s
&O-p6
&6-&O-6
tPs*ea
8*O-j$6

2.6f0.6
3*6j$6
6-O-&Y6
6-09-6
&6-j$6

269.6
P-6&0-6
3*6-&l-6
3.6kO.6
BOj-96

16&l
20f1
22f1
22*1
26fl

4&O-6
6f0*6
69.6
7fO.6
s*O-6

mm
i.696
2-S&O-6
36f06
S-5*0.6
&O&06

mm
32fl
36&l
4Ofl
4Of 1
42&l

mm
6*0*&a
&a*@6
S-09-6
8.096
11.Of@6

6
8
8
8
10

IS : 207 - 1964

9. PACKING
9.1 Gate and shutter
in quantities

as given

Size

hooks and eyes shall be packed


below:

Number of Mild
Steel Hooks and
Eyes in One Packet

in cardboard
Number

boxes

of Brass

Hooks and Eyes


in One Packet

mm
65
75
100
125
150
200
250
300

100
50

5:

2::
25
25

;:
;5
25
25

5:

10. MARKING
10.1 Each

box shall be labelled


mark, particulars
of quantity,
article.

with the manufacturers


description
of contents

10.1.1 The box may also be marked

with the Standard

name or tradeand size of the


Mark.

NOTE - The use of the Standard


Mark is governed by the provisions of the
Bureau of Indian Standards Act, 1956 and the Rules and Regulations made thereunder. The Standard Mark on products covered by an Indian Standard conveys
the assurance that they have been produced to comply with the requirements of that
standard under a well defined system OF inspection,
testing and quality control
which is devised and supervised by EIS and operated by the producer.
Standard
marked products are also continuously
checked by BIS for conformity
to that
Details of conditions under which a licence for
standard as a further safeguard.
the use of the Standard Mark may be granted to manufacturers or producers may
be obtained from the Bureau of Indian Standards.

11. SCALE OF SAMPLING

AND CRITERION

FOR CONFORMITY

11.1 Lot -In

any consignment,
all the hooks and eyes of the same
type and size manufactured
at the same time shall be grouped together to
constitute a lot.
11.2 Lot Size and Sample Size -The
number of hooks and eyes to be
selected from the lot shall depend on the size of the lot and shall be in
accordance
with co1 1 and 2 of Table III.

11.2.1 Hooks and eyes for testing shall be selected at random from at
least 10 percent of the packages subject to a minimum of three packages,
equal number of hooks and eyes being selected from each such package.

Is:m-1964
TABLE III

SCALE OF SAMPLING AND CRITERION FOR ACCEPTANCE


(Chuseu

LOT SrzE

501 ,, 800
801 and above

SAMPLE

11.2 and 11.4)


Pmall~~v~.

SIZlC

(2)
::

(3)
0

30
40
66

:
2
3

OP

No~p ---The Bampling plan given here ie euoh that late with 1% peroent
or lees defeotive will be aooepted moe.t of the times.

11.3 Number of Tests- All the hooks and eyes selected as in lL2 shall be
checked for defects in manufacture (see 5), dimensional requirements
Any hook or eye which fails to satisfy any
(see6)
and finish (see7).
one or more of the requirements for the characteristics shall be considered as a defective.
ll.4 Criterion for Conformity - The lot shall be considered as conforming to the requirements of this standard if the number of defective hooks
and eyes among those inspeeted does not exceed the corresponding
number given in co1 3 of Table III.
Otherwise it- shall be considered
as not conforming to the requirements of the standard.
.
11.41 For conformity to the requirements of the material the manufacturer shall provide a certificate of compliance to the requirements of
the corresponding Indian Standards ( see 4 ).

10

BUREAU OF

INDIAN STANDARDS

Headquarters :
Manak Bhavan. 9 Bahadur
Telephones

Shah Zafar Marg, NEW DELHI 110002

: 3 31 01 31.3

Telegrams : Manaksanstha
( Common to i 1 Offices I

31 13 75

Telephone

Regional Offices :
*Western

; Manakalaya,

E9 MIDC, Marol, Andheri ( East ), 6 32 92 95


BOMBAY 400093
tEastern : l/l4
C. I. T. Scheme VII M, V. I. P. Road,
36 24 99
Maniktola, CALCUTTA 700054
Northern : SC0 445-446,
Sector 35-C
21843
CHANDIGARH
160036
( 31641
Southern : C. I. T. Campus, MADRAS 600113
41 2442
{ dl2:

::

Branch Offices :
Pushpak, Nurmohamed Shaikh Marg, Khanpur,
AHMADABAD
380001
F Block, Unity Bldg. Narasimharaja Square,
BANGALORE 560002
Gangotri Complex, 5th Floor, Bhadbhada Road, T. T. Nagar,
BHOPAL 462003
Plot No. 82/83, Lewis Road, BHUBANESHWAR 751002
5315 Ward No. 29. R. G. Barua Road,
5th Byelane. GUWAHATI 781003
5-8-56C L N. Gupta Marg. (Nampally Station Road),
HYDERABAD 500001
Al 4 Yudhister Marg. C Scheme, JAIPUR 302005
117/418B

Sarvodaya

22 10 83
63471
{ 6 98 32
21 68 76
21 82 92
6 23 05
52 27

Patliputra Industrial Estate, PATNA 800013


Hantex Bldg ( 2nd Floor ), Rly Station Road,
TRIVANDRUM 695001
lnspecfion Office ( With Sale Point ):
( India ) Building,

1332 Shivaji

6 27 16
5 36 27

Nagar. KANPUR 208005

Institution
of Engineers
PUNE 410005

2 63 48
C 2 63 49
22 48 05

Nagar, 5 24 35

*Salea Office in Bombav is 6t Nov6lty


Chambers, Grant Road,
Bombay 400007
tSale6 Office in CSkUfta is at 6 Chowringhrr Approsch. P. 0. Princop
Street. CSkUtta 700072

89 66 29
27 68 00

Reprography Unit, BIS, New Delhi, India

AMENDMENT NO. 1

APRIL

1982

TO
1j:2(j7-?9~~

SpEclFlmTI~N
FOR GATE AND SHU7TER
HOOKS AND EYES

Altepzi~ions
--(Page

$,

c2ause

4.2)

Substitute

the following

for the existing clause:

4.1
Steel Mire - Mild Steel wire used in the manufactur~~f-h~o~and eyes shall conformto
1s:1812-1973
Specificationfor Carbon Steel Wire for Manufactureof
Mood Screws (fir6treV+SiOn).

(Page 4, cku6e 4.2.1, ttke8

2ant13) -Substitute

1S:3685-1966
Methods of CnemicalAnalysis of Brasses
~o~ 1s:441-1955
Method for Chemi:ca2 Analysis
or Brasses

and Bronzes.
(Pqe
S, ckuse
4.2.2) - Substitutethe following
for the existingclause:

b.2.2
Brass
wire
shall
have a minimum ultimatetensile
kg/mm2) and a
tensile st?ength0? 425 MPa (Sk2,5
minimum elongationat break of 15 percent,when tested
in accordancevith 1S:2656-1964
Method for Tensile
Testing of Copper and Copper Alloy Wire.

(page S, ch.U?Q S.2, Zine8 2 and 3) - Substitute


1S:451-1972TechnicalSupply Conditionsfor Wood
Screws (secondrevjdon)
for 1s:451-1961
Specification
far Wood Scwews (revi8ed).