You are on page 1of 2
24623 Proform Crosswalk 375E Voltage Diagram ‘Gone (wits power it) “Dig mutimetrs may have ifcaty measuring te sana ‘and may aly show a ‘maximum of 1.5 VOC, ‘Speed Sensor Paising § VOC. when bells moving (tog spay Ove Wor I Ty Bee saees = |3| | Sg aialsaise . a P aes F euscx é ae HO? Hp Les ca ice Moe no-noWACar ow Mc-2100-12 A] BLACK ony BLACK. when icine increasing Motor Controler “42> _| 410-120 VAC R to W" Lc3 AS ___} wiantorosestouna\ AVY a seis eb as ye fz px ve |8)8 Sasa cat opin ee (ee, a , fC 0 —~ — : Fert Orfonacn Powergen Great brner Faun Part #: 241176 5/2006 Drawing #: 241176- © Icon Health & Fitness, Inc. (ON (Blinking Quicky- The contaller has recaived a spe inal rom the console greater than 0.0 MPH. tis now Sending OC votiage tothe drive motor. Cnscio wil ‘apie in calbration mode level 5. ‘ON (Binking and off once per sscond) The conta operating atts curent mit Ths wil only occur the ontote shaving to work too hard to maintain specs Chick or high fcbon between the board and bet or an vertightened bet Consol dipiey'"4 in calbraton made level, ON (Biking VERY stow: One socond on, ope second ‘off The controller nas entered Fatback’ mose whore it reduces volage and amperage tothe dive motor. Tris fs ‘generally caused by a locked sive motor. Console wil {splay 30 In calbraton modo lvel 8 MC-2100 Motor Controller LEDs “The MC-2100 motor conten has @ single LEO thal can be used to hap troubleshoot ‘lctcal problems wth tis adil. Tha LED inciates Several siferent conditions. Each ‘oncton and the satus of tha LED are given bot. (OFF- When the LED isnot ith control isnot receiving power. the LED doos not come on laten powers applied, check the AC wiring belwesn the wal out and the conta ON (Sala) The controler is reesiving 120 VAC ‘and is functorng nermally. No speed signal has been recalved from the console and the treacle at res. Congoia will apy in calbration mode ove 5 Treadmill Specifications 24623 Proform Crosswalk 375E 0-10 MPH 1.5-10% Power incline 2.25 Horsepower Motor 250 Ib. Max. User Weight 15 Amp Circuit Breaker 120 VAC 60 Hz Tech Sheet Part #: 241176 (Calibration Mode 4 butons whi insoing the caer key satty hoy. Being contgured return othe previous value. ‘Ves Current sofware version number (OL: Front Roller siza 6" 'SPd. Maximum Spood of the reas 10" I Maximum nine 0" ‘Ths console has a ealration mode to assist the technician in troubleshooting To enter iis mode, press and hod the Stop and Speed "Thar ar dv lvals otis mode, Move rom one ova tothe next by pressing tho Stop button. Ex this mods at any tme by removing ie Levelt. This level dspays how the console has been configured to ‘Operate, also ceplays the numeral value of each buton as ts pressed. The console wil baep she mes to Indes the controler is “The cancte wil deplay one function at tine, The Time window wi splay tho name ofthe function le tho Calores window deploys the Seltng. Prose Spood a to advance to tho next value, Prose Spoed Wo Ine Minimum PWM speed contol percentage (rtorcept) "12 ‘batons convol th speed ofthe ightng patra none &lopglos aot the LEDs on and off Incine W restarts the lighing route. Level 4 This eval splays the total Tne and Distanco of he tread, ‘liso shows the curent uns of measurement PRIORITY: Total ima in hours DISTANCE: Total distance in mies SPEED (Lot) Unie: © “Engh, =metic SPEED (Right) Demo mode status‘ ifan blank of Leva S-Functonal Tost Ths lev! allows the treadmil oe tested while illincalbraton mod, The tread wil run normaly afer the Start ‘ution is prossed, but the displays wil show arent Infomation. TIME. Elapsod Time GALORIES (Let - Curent PWM speed conte! signal output 085 CGALORIES (Right )- Actual speed the teadmil ruaning 'SPEED- Speed the treadmil see to ran Prassing both Spood buttons fr tuo seconds wil cause the console to splay anaterate sereon wits tha folowing information "TIME DC votage tothe ave moter in vats ‘SPEED. PWM spoed signal ofthe moter contaor PRIORITY (Let 4}: Moto curent draw intents of an amp PRIORITY (Right /4}- Conor Stats: Orof, 1sosol, 2-HV buss ie Software configuration resus ‘e=conigured. no=not configured, released, nrenot releases ‘eS. Memory chock (checksum), FP Flash Pass, FF= Fash Fall PLS: Pulse input flashes win han pulse," with chest pulse 04: Bulton test values (dspiay code valve ofeach button) Pressing both Specd butons for wo eacands wil eau te console to isla an atornate soroon with tho fcwing information “TIME Control Max. Speed Pot valve, GALORIES- Cantor software version number. PRIORITY (Lot. Current matin tenths ofan Amp "18° PRIORITY (Right 4} Compensation In tonths of vals per amp 08 Level 2- This levels used to calibrate the incline and speed ofthe ‘weadmil. To calbrate icine, press other Inne button. Th tread ‘wil calbate ise. To calibrate speed, press and hold the Speod a. Bulton und tho Distance window daplay an 65% speed signal. Adjust the MAX SPD pot on te contrat unfi tha Speed window splays 10°, Pross Speed W and alow the Yosdmil 9 como a compete stop. PRIORITY. Blank ‘SPEED. Actual speod of the treadmil DISTANCE. Curt PW sped signal (%) 0-85" Level 3- This levelights each LED onthe console in ore. The Speed HV buss ls charging: 6=volags to mote, reagmil Is. uront Lit has beon reached, 30= Fold-Back™ ‘mode... contol reduces valtage to dive matoro prevent Svorneating. Pressing both Speed buttons fortwo seconds wil cause tho deply to tune tera plays Units of Measurement The uns of measurement can be changed betwoen English and Meticin the User iformation Made. Enis this mode by pressing own the Stop button while inserting the key. The Spood window wl isola ether for Engian or for mote unt of measurement. Toggle between the two stings by pressing the Speed a bution. Demo Mode “Tho console has demo bul ino sofware, The demo mode toons the console display trough a ighing routine when tho reedm i plugged in, but he kay Ie not nsrted. Al buton proses ro isabiod. To clsabe this mode, ener the Usor Iormaton mode by pressing down the Stop button wa Insetng the kay. The Speed window wil display ae fdemo mages activo, Press tha Speed ¥ butlon to toggle the mode on and ot SERVICE HISTORY SERVICE PERFORMED. DATE TECH#

You might also like