Triaxial Test: Xzdetermination of Shear Parameters by Triaxail Test
Triaxial Test: Xzdetermination of Shear Parameters by Triaxail Test
Triaxial Test Cell without transparent chamber capable of resisting internal fluid pressure of 1000
kN/m2.complete with all accessories.
2. An Apparatus for Applying and maintaining the Desired Pressure on the Fluid Within the Cell to an
accuracy 10 or 5 kN/m2.
3. Compression machine, capable of applying axial compression to the specimen at convenient speed to cover
the range 0.05 to 7.5 mm/min.
4. Dail guage to measure axial compression accurate to 0.04.
5. Seamless rubber membrane
6. Membrane stretcher
7. Rubber rings
8. Split mould, trimming knife, wire saw meter straight edge, sample extruder, thin walled tubes, soil lathe.
Meter box
9. Water containment determination tins
10. Balance
11. Stop watch
THEORY
Sample preparation
1.
Undisturbed specimen
a) If the undisturbed sample has been collected in a thin walled tube having the same internal diameter as
that of the specimen required for testing, the sample may be extruded out with the help of sample
extruder, and pushed into the split mould. The sample should be extruded from the tube pushing from
the cutting edge side. The ends of the specimen are trimmed flat and normal to its axis. The split mould
should be lightly oiled from inside. The specimen is then taken out, carefully, from the split mould, and
its length, diameter, weight should be measured to an accuracy enabling the bulk density to be
calculated to an accuracy of plus or minus 1 percent. A portion of the soil trimmings is placed for water
content determination. The specimen is then placed on one of the end caps and the other using the
membrane stretcher. The membrane is sealed to the end caps by means of rubber rings. The specimen
is then ready to be placed on the pedestal in the triaxial cell.
b) If the undisturbed soil sample brought from the field is of large diameter than the specimen diameter,
the sample may be cut to size either by means of thin walled tube or hand trimming or by a soil lathe.
If a block sample has been obtained from the field, a rectangular prism slightly larger than the required
final dimensions of the specimen is cut from the block sample. The ends of prism are made plane and
parallel using meter box. The prism is then placed in the soil lathe, and excess soil is cut off in thin
layers. The trimming operation, rotating the sample between end cutting operation, is continued until a
cylindrical specimen results. The rest of the procedure for enclosing the specimen in the membrane
etc., is the same as described in step (a).
Practical report
Page 1
Triaxial test
2.
Remoulded specimen.
Remoulded samples prepared at the desired moisture and density by static and dynamic methods of
compaction and then preparing the cylindrical specimen of required dimensions by the methods described
in (b) above.
Practical report
Page 2
Triaxial test
TEST PROCEDURE
1.
2.
3.
Prepare cylindrical remoulded specimens by compacting the soil manually in the compacting apparatus at
required water content.
Trim the soil specimen by using trimming apparatus if necessary and trimmed specimen should be 76mm
long and diameter should be 38mm
The specimen is then closed in 38 mm dia. and about 100mm long rubber machine using the membrane
stretcher. Spreading back the ends of the membrane over the stretcher and applying suction between the
stretcher and the rubber. Stretcher is then easily slide over the specimen, suction is released and the
membrane is unrolled from the ends of the stretcher.
4.
Use non-porous stone on either side of the specimen as neither any pressure is not to be measured nor any
drainage of air or water is allowed.
5.
Remove the porous cylinder from its base removing the bottom fly nuts.
6.
The pedestal at the center of the base of the cylinder on which the specimen is to be placed in cleaned and a
38 mm dia rubber 0-ring is rolled over to its bottom. The specimen along with the non-porous plate on
either side is centrally placed over the pedestal and the bottom edge of the machine covering the specimen
is sealed against the pedestal by rolling back the 0-ring over the membrane.
7.
The cap is placed over the top plate of the specimen and the top of the rubber membrane is sealed against
the cap by carefully rolling over it another 0-ring. This arrangement of the rubber 0-ring forms the effective
seal between the specimen with the membrane and the water under pressure. The specimen is checked for
its vertically and co-axially with the cylinder chamber.
8.
The chamber(cylinder) along with the loading plunger is carefully placed over its bases without disturbing
the soil specimen and taking care to see that the plunger rest on the cap adjusted so that it just touches the
plunger to by the naked eye. The chamber is than rotated if necessary such that the dial gauge recording
that compression rests centrally over the top of the screw which can be locked at any level and which is
Practical report
Page 3
Triaxial test
attached to the top of the cylindrical chamber carrying the specimen. The cylinder is then attached to the
base plate tightly by means of the tightening the nuts.
9.
The valve to drain out the chamber and the valve to drain out the air and the water from the sample are
closed and the air lock nuts at the top of the cylinder is kept open to facilitate the exit of air on the water
enters the cylinder
10. The water storage cylinder is filled with water completely and its top is then closed by mean s of a valve.
Desired pressure (50KN/m2) is built up in the cylinder by working the hand pump and pressure is
maintained constant in the cell.
11. For this position, adjust the deformation dial gauge and proving ring reading to zero.
12. Record the initial readings of the proving ring and compression dial gauge.
13. The vertical load is applied to the specimen by starting the mortars at the loading frame. The change in the
proving ring dial gauge gives the measure of the applied load. The deformation dial gauge gives the
measures of the applied load. The deformation dial gauge gives the deformation in the soil specimen, which
can be used to compute strains in the soil
14. Take the reading of proving ring dial gauge at 0.5, 1.0, 1.5, 2.0%(or any other smaller values)of the strain
and for every 0.5% strain thereafter up to failure or 20% strain whichever is the earlier .
15. Throughout the test, make sure that the chamber, containing pressure is kept constant at the desirable values
as indicated by the pressure gauge as the water cylinder.
16. After the specimen has failed or 20%strain is reached:a.
b.
Disconnect the chamber from the water storage cylindrically closing the lingers values
c.
d.
Open the valves to drain out the water in the cylinder. After a few seconds, open the air lock nut of
air at the top of the cylinder.
17. After the water is completely drained out, take out the cylinder from the loading frame carefully, loosen the
nuts and remove the Lucile cylinder from its base without disturbing the sample.
18. Note the space of the failed specimen, angle of the shear plane if any and dimensions of the specimen.
FORMULAE
A=
Ao
1e
Where,
Ao = initial area of the specimen normal to the axis
e = (Lo-L)/Lo
where,
Lo = initial length of the specimen, and
L = length of the specimen at the stage of test at which area is to be determined
Practical report
Page 4
Triaxial test
The principal stress difference (
76mm
38mm
50KN/m2
)=
OBSERVATION TABLE:
Strain
Displacemen
t
In dial gauge
Reading(div)
Displacemen
t
(mm)
L
*100
(%)
Proving
ring
Readin
g
(div)
Load
(KN)
Corrected
Area
(
Deviator
Stress
Shear
stress
1 3
2
m2 )
(
KN
m2
0
0.5
0
0.66
0
1.2
100
150
200
250
300
350
400
450
1
1.5
2
2.5
3
3.5
4
4.5
1.316
1.974
2.632
3.289
3.947
4.605
5.263
5.921
12
30
47
64
81
89
75
58.8
Practical report
0
0.02
4
0.24
0.6
0.94
1.28
1.62
1.78
1.5
1.17
0.001142 21.016
0.001149
0.001157
0.001165
0.001173
0.001181
0.001189
0.001197
0.00121
Page 5
208.88
518.58
806.87
1091.22
1371.72
1497.06
1253.13
971.9
1+ 3
2
(
KN
m2
0
50
Normal
stress
KN
m2
0
10.508
0
60.508
104.44
259.29
403.44
545.61
685.86
748.53
626.57
485.95
154.44
309.29
453.44
595.61
735.86
798.53
676.57
535.95
Triaxial test
6
Sample calculation:
Diameter of sample
38 mm=0.038 m
2
2
( A0 ) d =0.00113411 m
4
=0.5 mm=0.005 m
Displacement
Load 0.021.2=0.024 KN
Strain
0.005
( )= 100 =
100 =0.66
L
0.076
( A )=
A0
=0.001142 m2
1
load
0.024
Deviator stress
Principle stress
( 3 ) =50 KN /m2
Shear stress
( 1 ) = d + 3=71.016 KN /m2
1 3 71.01650
=
=10.508 KN /m2
2
2
Practical report
Page 6
Triaxial test
Normal stress=
1+ 3
=60.508 KN /m2
2
Graphical representation
Shear stress vs nominal stress
800
700
600
500
nominal stress(KN/m2)
Practical report
Page 7
Triaxial test
800
600
400
200
0
0
strain(%)
Result:
1.
Cohesion, Cu = 0
2.
3.
4.
5.
Recommendation:
Shear failure is diagonal. The soil used in this Triaxial test is found to be cohesion less as Cu=0.
Since it is cohesion less it cannot be used for building purposes.