Professional Documents
Culture Documents
Cabling - Standards
Cabling - Standards
Cabl-New-2003-Engl - 1
May 2007
Copyright note
These slides are protected by copyright and international treaties. The title and the
copyrights concerning the slides (inclusive
(inclusive, but non only,
only every image
image, photograph,
photograph
animation, video, audio, music and text) are the authors (see Page 1) property.
The slides can be copied and used by research institutes, schools and universities
affiliated to the Ministry of Public Instruction and the Ministry of University and
S i tifi Research
Scientific
R
h and
d Technology,
T h l
for
f institutional
i tit ti
l purpose, nott for
f profit.
fit In
I this
thi
case there is not requested any authorization.
Any other complete or partial use or reproduction (inclusive, but not only,
reproduction
p
on discs,, networks and printers)
p
) is forbidden without written
authorization of the author in advance.
The information contained in these slides are believed correct at the moment of
publication. They are supplied only for didactic purpose and not to be used for
installation-projects
installation
projects, products,
products networks etc.
etc However,
However there might be changes
without notice. The authors are not responsible for the content of the slides.
In any case there can not be declared conformity with the information contained in
these slides.
In any case this note off copyright may never be removed and must be written also
in case of partial use.
Cabl-New-2003-Engl - 2
May 2007
Approved
pp
byy CENELEC in November 2002
This
Cabl-New-2003-Engl - 3
May 2007
Essential changes
g include the following:
g
Centralized
May 2007
EN 50173-1
50173 1 foreword (3th part)
The first edition of this European
p
Standard had been
developed to enable the application-independent precabling of office premises.
Its
I basic
b i principles,
i i l
however,
h
are applicable
li bl also
l in
i
various other situations including industrial premises and
residential buildings
Cabl-New-2003-Engl - 5
May 2007
EN 50173-1 scope
This European
p
Standard specifies
p
generic
g
cabling
g for use
within premises which may comprise single or multiple
buildings on a campus.
It covers balanced cabling and optical fibre cabling.
Safety (electrical safety and protection, fire, etc.) and
elect omagnetic compatibilit
electromagnetic
compatibility (EMC) requirements
eq i ements are
ae
outside the scope of this European Standard and are
covered byy other standards and regulations.
g
Cabl-New-2003-Engl - 6
May 2007
EN 50173-1: applications
The standard is optimised
p
for premises
p
in
which the maximum distance over which
telecommunications services have to be
distributed is 2000 m.
m
The principles of this European Standard
may also be applied to larger installations.
installations
This standard contain informations and
specifications
p
usefull for generic
g
cabling
g
system project
Cabl-New-2003-Engl - 7
May 2007
Building A
Building C
Telecommunication
Outlet
Floor
Distribution
Building B
Building
Distribution
Building
Backbone
Campus
Backbone
Campus
Di t ib ti
Distribution
Cabl-New-2003-Engl - 8
May 2007
EN 50174 -1
Information
EN 50174-2
Information
EN 50174-3
50174 3
Cabling
Cabl-New-2003-Engl - 9
May 2007
building
distributor (CD);
distributor (BD);
floor
distributor (FD);
h
horizontal
l cable;
bl
consolidation
point (CP);
multi-user
multi
user TO assembly;
work
area (WA);
telecommunications
Cabl-New-2003-Engl - 10
outlet (TO).
P. Nicoletti: see note pag. 2
May 2007
Campus
backbone
cabling subsystem
BD
FD
Building
backbone
cabling subsystem
CP
TO
Terminal Equipment
Work area
cabling
Cabl-New-2003-Engl - 11
May 2007
Optional cable
Optional
Optional dstributor
dstributor
Optional cable
Cabl-New-2003-Engl - 12
May 2007
Campus backbone
backbone cable
cable
Campus
Campus
backbone
cable
Equipment room
Cabl-New-2003-Engl - 13
External network
P. Nicoletti: see note pag. 2
May 2007
Interconnect model
Equipment Cord
Equipment Cord
Cabling sub-system
Cabling
sub-system
Cabling
g sub-system
y
C bli sub-system
Cabling
b
Cabling sub-system
Cabling
Cabling sub-system
sub-system
Trasmission/terminal
equipment
Trasmission/terminal
equipment
Cabl-New-2003-Engl - 14
May 2007
Crossconnect model
Equipment Cord
Cabling sub-system
Patch Cord or
Jmper
Patch Cord or
Jmper
Cabling sub
sub-system
system
Cabling sub-system
Trasmission/terminal equipment
Cabl-New-2003-Engl - 15
May 2007
Cabl-New-2003-Engl - 16
May 2007
The number
u b and
a d type
yp of
o subsystems
ub y
that
a are
a included
ud d in
a generic cabling implementation depends upon:
the
campus distributor;
one building distributor per building;
one floor distributor per floor.
If the premises comprise only a single building which is
small enough to be served by a single building distributor,
distributor
there is no need for a campus backbone cabling
subsystem.
Cabl-New-2003-Engl - 17
May 2007
Cabl-New-2003-Engl - 18
May 2007
Cabl-New-2003-Engl - 19
May 2007
Combined
BD and FD
Cabl-New-2003-Engl - 20
May 2007
1st floor
Basement
Building entrance
cable 1
Cabl-New-2003-Engl - 21
Building entrance
cable 2
P. Nicoletti: see note pag. 2
May 2007
Category 5 and 6
connecting hardware
Cabl-New-2003-Engl - 22
Category 7
connecting hardware
May 2007
Cabl-New-2003-Engl - 23
May 2007
Category 5, 6 or 7
The
Category
g y 5,, 6 or 7
Each
Cabl-New-2003-Engl - 24
May 2007
Single
S
g e use
user TO
O asse
assembly:
by
serves
Cabl-New-2003-Engl - 25
May 2007
Multi-user
u t use TO
O asse
assembly
b y ((MUTO)in
U O) a
an ope
open office
o ce
environment, a single assembly of TOs may be used to
serve more than one work area:
Shall
May 2007
Consolidation Point
Cabl-New-2003-Engl - 27
May 2007
Consolidation Point
May 2007
Cabl-New-2003-Engl - 29
May 2007
Cabl-New-2003-Engl - 30
May 2007
Equipment cord
Cabl-New-2003-Engl - 31
May 2007
Model
Equipment
q p
cord
Cabl-New-2003-Engl - 32
Patch cord/
jumper
May 2007
Model
Equipment cord
CP cable
bl
Cabl-New-2003-Engl - 33
W k area cordd
Work
May 2007
Model
cord/
Equipment cord Patch
jumper
Cabl-New-2003-Engl - 34
CP cable
May 2007
If
Cabl-New-2003-Engl - 35
May 2007
Cross-connect TO
H = 109 - FX
H = 107 - FX
Interconnect - CP TO
H = 107 - FX - CY
Cross-connect - CP TO
H = 105 - FX - CY
Class E
Class F
H = 107 3(a) FX
H = 107 2(a) FX
H = 106 3(a) FX
H = 106 3(a) FX
H = 106 3(a) FX CY
H = 106 3(a) FX CY
H = 105 3(a) FX CY
H = 105 3(a) FX CY
Combined length of patch cords, jumpers, equipment and work area cords (m)
Ratio of flexible cable attenuation (dB/m) to fixed horizontal cable attenuation (dB/m)
(a) This length reduction is to provide an allocated margin to accommodate insertion loss deviation.
For operating temperatures above 20 C, H should be reduced by 0,2% per C for screened cables
and 0,4% per C (20 C to 40 C) and 0,6% per C (> 40 C to 60 C) for unscreened cables.
Cabl-New-2003-Engl - 36
May 2007
the p
physical
y
length
g of the fixed horizontal cable shall not
exceed 90 m and may be less depending on the length of
CP cables and cords used and the number of connections;
where
h
a multi-user
lti
TO assembly
bl is
i used,
d the
th length
l
th off the
th
work area cord should not exceed 20 m;
when
used,
used a CP should be located at least 15 m from the
floor distributor in order to reduce the effect of multiple
connections in close proximity on NEXT and return loss;
the
Cabl-New-2003-Engl - 37
May 2007
Class
B is specified up to 1 MHz.
Class
C is specified up to 16 MHz.
Class
Class
Class
Cabl-New-2003-Engl - 38
May 2007
loss
NEXT
PSNEXT
ACR
PSACR
Return
R t
LLoss
ELFEXT
PSELFEXT
link
channel
Cabl-New-2003-Engl - 39
May 2007
Permanent
PermanentLink
Link
Link
Permanent
Equipment cord
Cabl-New-2003-Engl - 40
Work area
cord
May 2007
Permanent Link
C
CP
Equipment cord
Consolidation
Point
Cabl-New-2003-Engl - 41
Work area
cord
May 2007
Channel attenuation
Cabl-New-2003-Engl - 42
May 2007
Channel NEXT
Cabl-New-2003-Engl - 43
May 2007
Channel PSNEXT
Cabl-New-2003-Engl - 44
May 2007
Channel ACR
Cabl-New-2003-Engl - 45
May 2007
Channel PSACR
Cabl-New-2003-Engl - 46
May 2007
Cabl-New-2003-Engl - 47
May 2007
Channel ELFEXT
Cabl-New-2003-Engl - 48
May 2007
Channel PSELFEXT
Cabl-New-2003-Engl - 49
May 2007
Cabl-New-2003-Engl - 50
May 2007
Cabl-New-2003-Engl - 51
May 2007
Cabl-New-2003-Engl - 52
May 2007
Cabl-New-2003-Engl - 53
May 2007
Cabl-New-2003-Engl - 54
May 2007
Cabl-New-2003-Engl - 55
May 2007
Cabl-New-2003-Engl - 56
May 2007
Cabl-New-2003-Engl - 57
May 2007
Backward compatibility
p
y means that mated connections
with plugs and sockets from different categories shall
meet all requirements for the lower category component.
Cabl-New-2003-Engl - 58
May 2007
The optical
p
fibre shall be multimode,, graded-index
g
optical
p
fibre waveguide with nominal 50/125 m or 62,5/125 m
core/cladding diameter complying with A1a or A1b optical
fibre respectively,
fibre,
respectively of EN 60793
60793-2-10:2002.
2 10:2002
Maximum attenuation
dB/K
dB/Km
Category
850 nm
1300 nm
850 nm
Effective Laser
Launch
1300 nm
OM1
3,5
1,5
200
500
not specified
OM2
3,5
1,5
500
500
not specified
OM3
3,5
1,5
1500
500
2000
May 2007
optical
p
fibre shall comply
p y with B1 fibre of EN 60793-250:2002.
The
The
Cabl-New-2003-Engl - 60
Maximum attenuation
dB/km
1310
1,0
1550
1
1,0
0
May 2007
copper cables
Fiber optic cables
characteristics
Applications and connection Classes
Cabl-New-2003-Engl - 61
May 2007
Channel
Backbonecable
cable
Backbone
Equipment
cord
Equipment cord
Cabl-New-2003-Engl - 62
Patch cord/
j
jumper
May 2007
Component
Category
A
2000
B = 250 - FX B = 170 - FX
B = 105 - FX
2000
B = 260 - FX B = 185 - FX
B = 111 - FX
B = 105 - 3(b) - FX
2000
B = 260 - FX B = 190 - FX
B = 115 - FX
B = 107 - 3(b) - FX
Length
g of the fixed backbone cable ((m))
F
X
B = 105 - 3(b) - FX
((a)) Applications
pp
limited by
yp
propagation
p g
delay
y or skew may
y not be supported
pp
if channel lengths
g
exceed 100 m.
(b) This length reduction is to provide an allocated margin to accommodate insertion loss deviation..
Where channels contain a different number of connections than in the model shown in Figure 8, the fixed cable length shall
be reduced (where more connections exist) or may be increased (where fewer connections exist) by 2 m per connection for
Category 5 cabling and 1 m per connection for Category 6 and 7 components. Additionally, the NEXT, Return Loss and
ELFEXT performance should be verified.
For operating temperatures above 20 C, B should be reduced by 0,2% per C for screened cables and 0,4 % per C (20 C
t 40 C) and
to
d 0,6%
0 6% per C ((> 40 C tto 60 C) for
f unscreened
d cables.
bl
Cabl-New-2003-Engl - 63
May 2007
Patched
P h d
combined
bi d channel
h
l
Spliced
combined channel
Di
Direct
t combined
bi d channel
h
l
Cabl-New-2003-Engl - 64
May 2007
Patched
Patched combined channel
Backbone cable
Channel
Patch cord/
jumper
Fixed horizontal
cable
Area
CP Cable Work
cord
Fixed horizontal
cable
Cabl-New-2003-Engl - 65
May 2007
Fixed horizontal
cable
bl
Fixed horizontal
cable
Cabl-New-2003-Engl - 66
May 2007
CP Cable
Work Area
cord
Cabl-New-2003-Engl - 67
May 2007
Optical
p
fibre channel parameters
p
Optical fiber type
Class
Multimode
Cable Category
OM1/OM2/OM3
850 nm
1300 nm
OF-300
L = 735 145 x X 90 x Y
300
OF-500
L = 935 145 x X 90 x Y
500
OF-2000
L = 2435 145 x X 90 x Y
2000
Singlemode
OS1
Maximum
length m
Implementation equations(a)
1310 nm
1550 nm
OF-300
300
OF-500
500
OF-2000
2000
(a) These equations assume 0,5 dB attenuation per mated connection (as for a two connection system only 0,25 %
would exceed that value)
Cabl-New-2003-Engl - 68
May 2007
Singlemode
g
(physical
(p y
contact):
) blue
Cabl-New-2003-Engl - 69
May 2007
maximum attenuation:
0,5
, dB for 95% of matings
g
Splice
p
Minimum
return loss:
Multimode 20 dB
Siglemode 35 dB
Cabl-New-2003-Engl - 70
May 2007
ELECTROMAGNETIC CHARACTERISTICS
Cabl-New-2003-Engl - 71