CPUB-B was halted due to the CP fault therefore there was no redundancy of
CPs.If the only CPU,CPUB-A failed then the whole BSC was going to fail.
<dpwsp;
CP STATE
MAU SB SBSTATE
AAM B HA-FM
RPH-A
-
RPH-B
BUA STATE
1
PROBLEM SYMPTOMS
A3/APZ "ZWBSC06_G13B_IP" 244 141216 1436
CP FAULT
REMEDY CONDITIONS
1. CPUB board was faulty.
2. CPUB-B was halted.
3. CP fault was evidenced by commands:
(i) ALLIP:ALCAT=APZ;
ALARM LIST
A3/APZ "ZWBSC2_G13B_IPA" 033 150723 2044
CP FAULT
(ii) dpwsp;
CP STATE
MAU SB SBSTATE
NRM B WO
END
<repci;
REPCI;
<;
ORDERED
<
WO
ZWBSC2_G13B_IPA06
CP DIAGNOSIS
TEST RESULT
FAULT
FAULTTYPE
PERMANENT
MAG
PCB
REPLACED REASON
CPU
STUD-B-0
CPU
POWC-B
END
(5) End CP diagnosis
REPCE;
(6)Peform backup:
-Check System Functions Backup
SYBFP:FILE;
-Passivate the automatic output function.
SYBUE;
-Initiate the output of a system backup copy:
SYBUP:FILE;
-Initiate the updating of backup generations for a consecutively numbered sequence of
backup files within the same file range
SYTUC;
-Initiate a rotaion of the system backup to RELFSW0
SYBFP:FILE;
-Activation of automatic system backup:
SYBUI;
SOLUTION(S)
NB: PLEASE REPLACE ONE BOARD AT A TIME
RPH-A
-
RPH-B
BUA STATE
1
END
(6) Printing recorded information about hardware faults in the Central Processor
DIRCP;
(7) Printing the hardware identities of all the boards in the CP.
DPHIP;
(8)Checking processor load
PLLDP;