You are on page 1of 39
(G+2) RESIDENTIAL VILLA FOR MR. SAEED RASHED AJTABI PLOT NO. 8411474 MARGHAM, DUBAI, UAE Division No. 07 ‘THERMAL & MOISTURE PROTECTION WORKS (G+1) RESIDENTIAL VILLA FOR MR. SAEED RASHED AITAB| : PLOT NO. #411474 MARGHAM, OUBAI, UAE : Mimcsenjss Division No. 07 - THERMAL AND MOISTURE PROTECTION” "= ace racigtie. z i Rae 7 Atrount iz ee | DlvIStoN 07 - THERMAL AND MOISTURE PROTECTION sy and apply moisture isolation wate includ | furnish all necessary labor, materials, tools and ete, to complete the! lwork, as snzcified in drawin 8 | Sub structure | ‘8 [supp and apply 1000 gauge alytheneshest under PCC for mt | 2090 [foundation and slab on grade, as shown on drawings and detailed i [specication 85 Supply and apaly one-coatsbituminaus coating; complete alas 1262 |“ [row on crwing and spcteaton oreoralyto ground lad, | © [supply and apolytwo-coats bituminaus coating; complete alas | mq? | 2583, shown an drawing and saseifcation, hozantallyand vertically to foundations | sundries 150 ceep isolation joints including 12mm thick ex colboard with {isin filler. Wot Areas, [supply and apply Cold fluid applied single component unmodified polyurethane waterproofing; coal tar free, pure slid, seamless, jaint free, water and weather-tight elastomeric membrane; complete; 2s specified; applied to floors and up stands, as on Drawing and specified in section 071416. € [wer Areas mt | 202 F {Balcony (over an Open Space) mi} | Cartied to Collection) Page 1 of S Div. O7 : Thermal and Moisture Protection, [(G+1) RESIDENTIAL VILLA FOR MR. SAEED RASHED AITABI |PLOT NO. £41474 MARGHAM, DUBA\, UAE mencsenfia 4. Division No. 07- THERMAL AND MOISTURE PROTECTION, “"" "78" Soro T = a ao Se DIVISION 07 - THERMAL AND MOISTURE PROTECTION (cont'd) ‘Roofing System A. |Suppiy and apply polyurethane foam with 4Smm thickness and 50 636 kkg/o3 density for roof Roors and up stand, as on Drawing and i ‘specified in section 975700, 8. Supelyendappy Pohtxliqudukrmioletprotecsoncost 600 | i | 686 micron thickness, fully bonded complete for rot floors and up stand and parapets. |Supoly and apsiyloosey laid geotextiles separation polveb iter | gx’ | 696 |embrane, 1300 micron thickness wt protective coating 120 65M) Icomplete for roof floors 1 |Suppiy and apply concrete screed 28 N/mm2 and 350 0PC to stone 696 Jutth average thickness 8 cm for raof floors complete with poyfiex |{sombo) elastromeric cementitious waterproof coating over entire roof area including up stands. 696 € JPolfox (combo) elastromeric cementitious waterprot costing | Jover entire root area neuding up stands. | | {Supp and aply 10s10em and cement angle il flly bonded for roo, up stands, parapets and mechanical openings complete m | 430 [Supply and install heavy duty elastomeric polysulphide olnt m | 430 | sealants and backing rede forall construction and contro joints as {shown in tne rauings and as per engineors recommendation, at |on Drawing nd spctiedn section 079200, i ‘aried to Collection = i Page 2 5 - DW. 07 : Thermal and Moisture Protection {(G+2) RESIDENTIAL VILLA FOR MR, SAEED RASHED AITABI PLOT NO, 8411474 MARGHAM, DUBAI, UAE EICSecpaa MOISTURE PROTECTION *” a Division No. DIVISION 07 THERMAL AND MOISTURE PROTECTION (cont'd) | ‘TENDER ADIUSTMENT: i au jeconiorwittsthereandricamytemsstewnonte | | | i leaves mentioned inte Specon oe eaed othe | fntacen compton beseten, tt rot mentoneain se | oa any ch tems tse xa be Seema be edad I | L ‘Garied to Collection) = Page dof Div, 07 : Thermal and Moleture Protection, | tt ((G+1) RESIDENTIAL VILLA FOR MR. SAEED RASHED AJTABI PLOT NO. 8411474 MARGHAM, DUBAl, UAE Division No. HERMAL AND MOISTURE Ten " Desuentn [DIVISION 07 - Thermal & Moisture Protection Works { { | ‘COMLECTION, From Page No, 1 ofS - Division O7 | From Page No, 2 of S- Division 7 From Page No. 3 of $- Division 07 From Page No. 4 of 5 - Division 07 SECTION 071 113 - BITUMINOUS DAMPPROOFING PART 1 GENERAL A 13 La RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section ‘SUMMARY ‘This Section includes the following: L.Colé-applied, emulsified-asphalt dampproofing Related Sections include the following: 1. Division 07. Section "Blastomeric Sheet Waterproofing Cold Fluid-Applied ‘Watesproofing” for waterproofing SUBMITTALS Product Data: For each type of product indicated. Include recommendations for method of application, primer, number of coats, coverage or thiciness, and protection course, ‘Samples: For the following products: |. 300-by-300-mmn square of waterproofing, Installer Certificates: Signed by manufacturers certifying that installers comply with requirements Qualification Data: For Tastaller, Product Test Reports: Based on evaluation of comprehensive tesis performed by a qualified testing agency, for waterproofing, Warranties: Special warranties specified in this Section Material Certificates: For each product, signed by manufacturers. QUALITY ASSURANCE, Source Limitations: bin primary dampproofing materials and primers through on source from 2 single manufacturer. Provide secondary materials recommended by ‘manufacturer of primary materials, BITUMINOUS DANPPROOFING wis (MR, SAEED RASHED AJTABI RESIDENTIAL VILLA 15 23 A mop @ PROJECT CONDITIONS ‘Weather Limitations: Proceed with installation only when existing and forecasted weather conditions permit dampproofing 10 be performed according to manufacturers’ written instructions. Ventilation: Provide adequate ventilation during application of dampproofing in enclosed spaces. Maintain ventilation until dampproofing has cured, PRODUCTS. ‘COLD-APPLIED, EMULSIFIED-ASPHALT DAMPPROOFING Available Manufacturers: Subject to compliance with requirements, manufacturers offering procucts that may be incorporated into the Work include, but are not limited to, the following: Degussa Building Systems; Sonneborn Brand Products. ‘Karnak Corporation. Meadows, W.R,, Ine. Fosroe Henkel ‘Trowel Coats: ASTM D 1227, Type TL, Class 1 Fibered Brush and Spray Coats: ASTM D 1227, Type Il, Class 1. Brush and Spray Coats: ASTM D 1227, Type Ill, Class 1 VOC Content: 30 gi. or less PROTECTION COURSE Protection Course, Asphalt Board Type: ASTM D 6506, premolded, 3-mm- thick, multi ply. semirigid board consisting of a mineral-stabilized asphalt core’ sandwiched between layers of asphalt-saturated felt, and faced on 1 sie with polyethylene film. ‘MISCELLANEOUS MATERIALS Emulsified-Asphalt Primer: ASTM D 1227, Type Ill, Class 1, except diluted with water as recommended by manufacturer Asphalt-Coated Glass Fabrie: ASTM D 1668, Type I Patching Compound: Epoxy or laex-modified repair mortar Manufacturers fibered mastic of type recommended by dampproofing manufacturer BITUMINOUS DAMPPROOFING Onis Me, Sako Raste AJTABIR: mecsejay) PART 3 - EXECUTION 31 32 A EXAMINATION Examine substrates, with Installer present, for compliance with requirements for surface ‘smoothness and other conditions affecting performance of work. 1, Proceed with dampprooting application only after substrate construction ard penetrating work have been completed and unsatisfactory conditions have been comecred. 2. Test for surface moisture according to ASTM D 4263, PREPARATION Protection of Other Work: Masi or otherwise protect adjoining exposed surfaces from being stained, spotied, or coated with dampproofing. Preveat dampproofing materials from entering and clogging weep holes and drains. Clean substrates of projections end substances detrimental to work; fll voids, seal joints, and apply bond breakers if any, as recommended! by prime material manufacturer Apply patching compound for filing and patching tie holes, honeycombs, reveals, and other Imperfections; cover with asphalt-voated glass fabric. APPLICATION, GENERAL Comply with manufacturer's written recommendations unless more stringent requirements ‘ue indicated ot required by Project conditions to ensure satisfactory performance of damppeooting, 1. Apply additional coats if recommended by manufacturer or if requited to achieve coverages indicated, 2. Allow each coat of dampproofing to cure 24 hours before applying subsequent coats 3. Allow 24 hours drying time prior to backfilling Apply dampproofing fo footings and foundation walls where opposite side of wall faces ‘occupied space. 1. Apply from finished-grade line to top of footing, extend over top of footing, and {down @ minimum of [50 mm over outside face of Footing, 2. Extend 300 mm onto intersecting walls and footings, but do not extend onto surfaces: exposed to view when Project is completed. 3. Install lashings and comer protection stcipping at intemal and extemal comers, changes in plane, construction joints, cracks, and where shown as “reinforced,” by fembedding an 200-mm- wide sirip of asphalt-coated glass fabric in a heavy coat of lampproofing. Dampproofing coat for embedding fabric isin addition to other coats required. Apply dampproofing to provide continuous plane of protection on exterior face of inner wwytle of exterior masonry cavity walls BITUMINOUS DAMPPROOFING ons 3 34 35 36 AJTAB! RESIDENTIAL VILLA 1, Lap dampproofing at least 6 mm onto flashing, masonry reinforcement, veneer ties, ‘and other items that penetrate inner Wythe. 2. Extend dampproofing over outer face of structural members and concrete slabs that interrupt inner wythe, and lap campproofing at least 6 mm onto shelf angles supporting veneer. Apply dampproofing to provide continuous plane of protection on interior face of above- srade, exterior concrete anc! masonry walls unless walls are indicated to receive direct application of paint. 1, Continue dampproofing through intersecting walls by keeping vertical mortar joints at intersection temporarily open or by delaying construction of intersecting walls until dampproofing is applied. COLD-APPLIED, EMULSIFIED-ASPHALT DAMPPROOFING n Concrete Founcitions and Parged Masonry Foundation Walls: Apply 2 brush or spray coats at not less than 0.6 sq, m for frst coat and 04 L/sq, m for second cont, 1 fibered torush or spray coat at not less than 1.2 Lisq, m, or I trowel coat at not less than 1.6 L/sq. m. ‘On Unexposed Face of Concrete Retaining Walls: Apply 1 brush or spray coat at not less than 0.5 Lisq. ‘On Unexposed Face of Masonry Retaining Walls: Apply primer and 1 brush or spray coat at not less than 0.5 Lisq.r, INSTALLATION OF PROTECTION COURSE Where indicated, install proiection course over completed-and-cured dampproofin. Cowply with dampproofing material manufacturer's written recommendations fer attaching protection course, 1. Install protection course on same day of installation of dampproofing (while coating is tacky) to ensure adhesion, CLEANING Remove dampproofing materials from surfaces not intended to receive dampprooting. END OF SECTION 071113 BITUMINOUS DAMPPROOFING OITIS-4 Meseqisa SHED ‘SECTION 071353 - ELASTOMERIC SHEET WATERPROOFING PART GENERAL Ll A 12 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. SUMMARY ‘This Section includes the following: 1, BPDM rubber sheet waterproofing. Related Sections include the following. Division 07 Section “Joint Sealants" for joint-sealant materials and installation, SUBMITTALS Product Data: Include manufacturer's writen instructions for evaluating, preparing, and treating substrate, technical data, and tested physical and performance properties of ‘waterproofing, ‘Shop Drawings: Show locations and extent of watemproofing, Include details for subsirwe joints and cracks, sheet flashings, penctrations, inside and outside comers, tie-ins with adjoining waterproofing, and other termination conditions. ‘Samples: For the following products: L. 300-by-200-aum square of waterproofing. Installer Certificates: Signed by manufacturers certifying that installers comply with requirements. (Qualification Data: For Installer. Product Test Reports; Based on evaluation of comprehensive tests performed by a qualified testing agency, for waterproofing, Warranties: Special warranties specified in this Section. QUALITY ASSURANCE Installee Qualifications: itm that is approved or licensed! by waterproofing manutecturer for installation of units required tor this Project. Source Limitations: Obtain waterproofing materials, protection course, through one source froma single manufacturer, ELASTOMERIC SHEET WATERPROOFING O35 T re Mockups: Before beginning installation, install waterproofing to 9.3 sq.m of wall to demonstrate surface prepartion, crack snd joint treatment, comer treatment, and execution quality 1. Af Architect determines mockups do not comply with requirements, reapply ‘waterproofing and reinstall overlying construction until mockups are approved. 2. Approved mockups may become part of the completed Work if undisturbed a: time of ‘Substantial Completion reinstallation Conference: Conduct conference at Project ste 1. Review waterproofing requirements including surface preparation, substrate condition and preteatment, minimum curing period, forecasted weather conditions, special details and sheet Mlashings, installation procedures, testing anc! inspection procedures, and protection and repaiz. DELIVERY, STORAGE, AND HANDLING Deliver liquid materials to Project site in original packages with seals unbroken, labeled with manufacturer's name, product brand name and ‘ype, date of manufacture, and rections for storiag and mixing with other components Store liquid materials in their original undamaged pacisages in a clean, dry, protected location and within temperature range required by waterproofing manufacturer. Remove andl replace liquid materials that cannot be applied within their stated shelf life Store rolls according to manufacturer's written instructions. Protect stored materials from direct sunlight. PROJECT CONDITIONS Environmenal Limitations: Apply waterproofing within the range of ambient and substrate ‘temperatures recommended by waterproofing manufacturer. Do not apply waterproofing to adamp or wet substrate 1. Do not apply waterproofing in snow, rain, fog, oF mist Maincain adequate ventilation curing preparation and application of waterproofing snaterials WARRANTY Special Manufacturer's Warranty: Manufacturer's standard form in which manufacturer ‘agrees to replace waterproofing material that does not comply with requirements or cha fails to remain watertight within specified warranty period. 1. Warranty Period: 20 years from date of Substantial Completion. Special Installe's Warranty: Specified form,signed by Installer, covering Werk of this Section, for warranty period of wo years ELASTONERIC SHEET WATERPROOFING WSS-2 (MR, SAEED RASHED AJTABI RESIDENTIAL VILLA PART 2 - PRODUCTS 21 SHEBT WATERPROOFING ‘A. EPDM Rubber Sheet: ASTM D 6134, Type .5-rim- thick exible sheet, unreinforced, forrned from EPDM. 1, Available Products: Subject to compliance with requirements, products that may be incorporated into the Work include, but are not limited to, the following: a. Carlisle Coatings & Waterproofing Inc.; Sure-Seal EPDM, b. Degussa Building Systems; Sonnebom Brand Products . Fosroc 4. Henkel 22 AUXILIARY MATERIALS, A. General: Fumish auxiliary materials recommended by waterproofing manufacturer for intended use and compatible with sheet waterproofing. 1. Fomish liquid-type auxiliary materials that comply with VOC limits of authorities having jurisdiction, B. Concealed Shoet Flashing: Same material, construction, and thickness as sheet ‘waterproofing or 1.5-mme thick, uncured EPDM as required by manufacturer. C. Exposed Sheet Flashing: 1.S-mm- thick EPDM, cured or uncured, as required by ‘manufacturer. 1D. Bonding Adhesives: Adhesive for bonding polymeric sheets and sheet flashings to substrates and projections. E, Splicing Cement and Cleaner: Single-component butyl splicing cement and solvent-based splice cleaner. 1. Butyt Gum Tape: 0.76-mm- thick-by-160-mm- wide, uncured butyl with polyethylene release fim. F,_ Lap Sealant: Single-component sealant. G. Water Cutoff Mastic: Butyl mastic sealant H, Waterproofing and Sheet Flashing Accessories: Provide sealants, pourable sealers, cone and vent flashings, inside and outside comer flashings, termination reglets, end other accessories recommended by waterproofing manufacturer for intended use, 1. Metal ‘Termination Bars: Manufacturer’ standard aluminum bars, approximately 25 mm. ‘wide, prepunched, with zinc-alloy-body fasteners and stainless-siee! pins. J. Protection Course: ASTM D 6506, semirigid sheets of fiberglass or mineral-reinforced- asphaltic core, pressure laminated between two asphalt saturated fibrous liners and as follows: ELASTOMERIC SHEET WATERPROOFING OSI MR, SAEED RASHED AJTAG! RESIDENTIAL VILLA loa lee 1. Thickness: 6 mm, nominal 2, Thickness: 3 mum, nominal, for vertical applications; 6 mam, nominal, elsewhere. 3. Adhesive: Rubber-dased solvent type recommended by waterproofing manufacturer for type of protection course, Protection Course: Extruded-polystyrene board insulation, unfaced, ASTM C 518, Type X, 13 ram thick, PART3- EXECUTION 3 32 33 A EXAMINATION Examine substrates, areas, ancl conditions, with Installer present, for compliance with roquirements and other conditions affecting performance. 1. Do not proveed with installation until after the minimum concrete curing period recommended by waterproofing manufacturer. 2. Verify that substrate is visibly dry and free of moisture. Test for capillary moisture by plastic sheet method according to ASTM D 4263. 3. Notify Architect in writing of anticipated problems using waterproofing over substrate 4, Proceed with installation only after unsatisfactory conditions have been comected. ‘SURFACE PREPARATION Clem, prepare, and treat substrates according (© manufacturer's written instructions. Provide clean, dust-free, and dry substrates for waterproofing application. Mask off adjoining surfaces not receiving waterproofing to prevent spillage and overspray affecting other construction. Remove grease, cil, bitumen, formerelease agents, paints, curing compounds, and other penetrating contaminants or film-forming coatings from coveret, Remove fins, ridges, mortar, and other projections and fill honeycomb, aggregate pockets, holes, and other voids Prepare, fill, prime, and treat joints and cracks in substrates. Remove dust and dirt from Joints and cracks according to ASTM D 4258, Prepare, teat, and seal vertical ancl horizontal surfaces at terminations and penetrations through waterproofing and at drains and protrusions. PARTIALLY ADHERED SHEET INSTALLATION Install partially adhered sheots over entire aren to receive waterproofing according %© manufacturer's written instructions. Accurstely align sheets and maintain uniform side and end laps of minimum dimensions required, Stagger end laps, BLASTONERIC SHEET WATERPROOFING Wasa F c 34 38 Massas Apply boning adhesive to the following areas of substrates and to each sheet at cequired rate and allow to partially dey 1. Upper 25 percent of length of each sheet and 457 mm around perimeter of each sheet. Firmly adhere sheeis to substrate. Do not apply bonding adhesive to splice area of sheet. Install partially adhered sheets and auxiliary materials to tie into existing waterproofing. Repair tears, voids, and lapped seams in waterproofing aot complying with cequirements. Slit and flaten fishmouths and blisters. Patch with sheet waterproofing extending beyond repaired areas in all directions. (COMPARTMENTED, LOOSELY LAID SHEET INSTALLATION Testall compartmented, loosely laid sheets over entire area to receive waterproofing ‘according to manufacturer's writen instructions. ‘Accurately align sheets and maintain uniform side and end laps of minimum dimensions required, Stagger end laps. Apply continuous beads of waier cutoff mastic, of size recommended by waterproofing manufacturer, to subsiraes in a 1500-by-1500-mm grid pattern before installing sheet Apply sheets wit side laps shingled with slope of deck whete possible, Spread sealant bed over deck drain flange at deck drains and securely seal sheet ‘waterproofing in place with clamping ring, Install compartmented, loosely laid sheets and auxiliary materials 10 tie into existing waterproofing Repair tears, voids, and lapped seams in waterproofing not complying with requirements, Slit and flatten fishimouths and bliswrs. Patch with sheet waterproofing extending beyond repaired areas in all directions SEAM INSTALLATION ‘Cement and Tape Splice: Clean splice areas, apply splicing cement and butyl gum tape, and firmly roll side and end laps of overlapping sheets according to manufacturers written instructions to ensure a watertight seam installation, Apply lap sealant and seal exposed edges of sheet Lerminations. ‘SHEET FLASHING INSTALLATION Install sheet Hlashings and preformed flashing accessories and adhere to substrates according, to waterproofing manufacturer's written instructions. Form wall lashings using exposed sheet fash Extend deck sheet waterproofing « form wall Mushings, ELASTOMERIC SHEET WATERPROOFING WISTS masaajaa MP, SAEED RASHED AJTABI RESIDENTIAL VILLA _ Patera {. Flash penetrations and field-formed inside and outside comers with uncured sheet flashing, 2 Clean splice areas, apply splicing cement, and firmly roll side and end laps of overlapping sheets to ensure a watertight installation. Apply lap sealant and seal exposed edges of sheet Mashing terminations, D. Cover expansion joints and discontinuous ceck-o-wall or decic-to-deck joints by extending deck sheet waterproofing over joints. E, Terminate and seal top of sheet flashings with mechanically anchored termination bars. 3.7 PROTECTION COURSE INSTALLATION A, Install protection course over waterproofing membrane according to manufacturer's written instructions and before beginning subsequent construction operations. Minimize exposure ‘of membrane, 3.8 FIELD QUALITY CONTROL, A. Flood Testing: Flood test each deck area for leaks, according to recommendations in ASTM D 5957, after completing waterproofing but before overlying construction is placed, Install temporary containment assemblies, plug oc dam drains, and flood with potable water. L. Flood to an average depth of 65 mm with @ minimum depth of 25 mm and not exceeding 4 depth of 100 mm, Maintain $1 mm of clearance from top of sheet flashings, Flood each area for 48 hours, Alter flood testing, repair leaks, repeat flood tests, and! make further repaits until ‘waterproofing installation is watertight. 1B, Engage an independent testing agency to observe flood testing and examine underside of decks and terminations for evidence of leaks during flood testing, 3.9 PROTECTION AND CLEANING A, Bo not permit foot or vehicular traffic on unprotected membrane, B, Protect waterproofing from damage and wear during remainder of construction period, C. Clean spillage and soiling from adjacent construction using cleaning agents and procedures recommended by manufacturer of affected construction, END OF SECTION 071353 TELASTOMERIC SHEET WATERPROOFING we ‘SECTION 071354 - THERMOPLASTIC SHEET WATERPROOFING PART | - GENERAL 1.1 RELATED DOCUMENTS ‘A. Drawings and general provisions of she Contract, including General and Supplementary Conditions and Division O1 Specification Sections, apply to this Section, 12 SUMMARY ‘A. This Section includes the following: 1. PVC sheet waterproofing. 2 This Section govems Glass Reinforced Plastic lining system installed by all trades throughout the building, including work under Division 7. B. Related Sections include the following: L.__Division 07 Section "Joint Sealants” for jointsealant materials and installation, 13 SUBMITTALS A. Product Data: Include manufacturer's written instructions for evaluating, preparing, and treating substrate, technical data, and tested physical and performance properties of waterproofing, B. Shop Drawings: Show locations and extent of waterproofing. Include details for substrate Jints and cracks, sheet flashings, penetrations, inside and outside comers, tie-ins with adjoining waterproofing, and other termination concitions. C. Samples: For the following products: 1, 300-by-300-mm square of waterproofing including all colors available of GRP lining ‘with all ts layers shall be used, D. Method statement and risk assessinent plan shall be submitted by the contractor for the approval of the Architect. Details of the layers shall be submitied by the contractor in accordance withthe design recommendation ofthe product's manufacturer. E, Installer Certificates: Signed by manufacturers certifying that installers comply with requirements. F,Qualifcstion Data: For Installer G. Product Test Repons: Based on evaluation of comprehensive tests performed by a qualified testing ageney, for waterproofing HE, — Warranties: Special warranties specified in this Seetion "THERMOPLASTIC SAEET WATERPROOFING OHSS MR, SAEED RASHED AJTASI RESIDENTIAL VILLA Cre 1 A mencsenjay QUALITY ASSURANCE Installer Qualifications: A firm that is approved or licensed by waterproofing manufacturer for installation of waterproofing required for this Project. Source Limiations: Obtain waerproofing materials, protection course, through one source froma single manufacture. Mockups: Before beginning installation, install waterproofing to 9.3 sq.m of wall to demonstrate sucface preparation, crack and joint treatment, corner treatment, and execution quality 1. If Architect determines mockups do not comply with requirements, reapply ‘waterproofing and reinstall overlying construction until mockups are approved, 2. Approved mockups may become part of the completed Work iF undisturbed at time of Substantial Completion reinstallation Conference: Conduct conference at Project site. L._Review waterproofing requirements including surface preparation, substrate condition and pretreatment, minimum curing period, forecasted weather conditions, special . Degussa Building Systems; Sonneborn Brand Products. ce. Fostac di Henkel, EXECUTION EXAMINATION Examine substrates, areas, and conditions, with Installer present, for compliance with requirements and other conditions affecting performance, L. Verify that concrete has cured and aged for minimum time period recommended by ‘waterproofing manufactures 2. Verily that substrate is visibly dry and free of moisture. Test for capillary moisture by plastic sheet method according to ASTM D 4263. 3, Proceed with installation only after unsatisfactory conditions have been corrected. SURFACE PREPARATION Clean and prepare substrate according to manufacturer's writen recommendations. Provide clean, dust-tee, and dy substrate for waterproofing application. Mask off adjoining surfaces not receiving waterproofing to prevent spillage or overspray affecting other construction, Close off deck drains and other deck penetrations to prevent spillage and migration of waterproofing fluid. Remove grease, oil, bitumen, form-release agents, painis, curing compounds, acid residues, and other penetrating contaminants or film-forming coatings from concrete. ‘COLD FLUID-APPLIED WATERPROOFING DiaIe-T MR. SAEED RASHED AJTASI RESIDENTIAL VILLA 35 pa wp (ean 1 Abrasive blast clean concrete surfaces uniformly to expose top surface of fine aggregate according to ASTM D 4259 with a scli-contained, recalculating, blast- leaning apparatus, Remove material to provide a sound surface fee of laitance, slaze, efflorescence, curing compounds, concrete hardeners, or form-release agents. Remove remaining loose material and clean surfaces according to ASTM D 4258, Remove fins, ridges, and other projections and fill honeycomb, aggregate pockets, and other voids. PREPARATION AT TERMINATIONS AND PENETRATIONS Prepare vertical and horizontal surfaces at terminations and penetrations through ‘waterproofing and at expansion joints, drains, and sleeves according to ASTM C 1471 and manufacturer's written instructions. Prime substrate unless otherwise instructed by waterproofing manufacturer Apply waterproofing in two separate applications, and embed a joint ceinforeing swip in the first preparation coat when recommended by waterproofing manufacturer 1. Provide sealant cants around penetrations and at inside comers of deck-1o-wall butt Joints when recommended by waterproofing manufacuurer. JOINT AND CRACK TREATMENT Prepare, reat, rout, and fill joints and cracks in substrawe according to ASTM C 1471 and waterproofing manufacturers written instructions. Remove dust and dir: from joints and cracks, complying with ASTM D 4258, belare coating surfaces. L. Comply with ASTM C 1193 for joint-scalant installation, 2. Apply bond breaker between sealant and preparation strip. 3. Prime substrate and apply a single thickness of preparation stsip extending a ‘minimum of 75 mm along each side of joint. Apply waterproofing in (wo separate applications and embed a joint reinforcing strip inthe First preparation coat. Install sheet flashing and bond to deck and wall substcates where indicated or required according to waterproofing manufacturer's written iasituctions, 1, Bxtend sheet flashings onto perpendicular surfaces and other work penetrating substrate according to ASTM C 898, WATERPROOFING APPLICATION Apply waterproofing according to ASTM C 1471 and manufacturer's written instructions. ‘Start installing waterproofing in presence of manufacturer's technical representative, Apply primer over prepared substrate Reinforced Waterproofing Applications: Mix materials and apply waterproofing by roller, notched squeegee, trowel, or other suitable application method. ‘COLD FLUID-APPLIED WATERPROOFING O71416-8 (MB, SAEED RASHED AJTABI RESIDENTIAL VILLA 36 a7 ed mesclas | 1. Apply first coat of waterproofing, embed membrane-reinforcing fabric, and apply second coat of waterproofing t completely saturate reinforeing fabric and to obtain a seamless reinforced memibrane free of entrapped gases, with an average dry film total thickness of 3 mm, 2. Apply reinforced waterproofing to prepared wall terminations and vertical surfaces 3. Verify wet film thickness of waterproofing every 9.3 sq, m. Tnstall protection course with butted joints over nominally cured membrane before stating subsequent construction operations 1, Insulation drainage panels Board insulation may be used in place of a separate protection course 19 vertical applications when approved by waterproofing ‘manufacturer, INSULATION INSTALLATION Install one or more layers of board insulation to achieve required thickness over waterproofed surfaces, Cut and fit to within 19 mm of projections and penetrations, On vertical surfaces, set insulation units in adhesive applied according to manufacturer's ‘writen instructions, Use type of adhesive recommended in writing by insulation ‘manufacturer. (On horizontal surfaces, place insulation units unadhered according to manufacturer's writen instructions. Singger end joints and tightly abut insulation units (CURING, PROTECTION, AND CLEANING Cure waterproofing aeconding to manufacturer's written recommendations, taking care 10 prevent contamination and damage during application siages and curing, 1. Do not permit foot or vehicular traffic on unprotected membrane, Provect waterproofing from damage and wear dusing remainder of construction period, Protect installed board insulation insulation drainage panels from damage due to ulteaviolet light, harmful weather exposures, physical abuse, and other causes, Immediately after installation, provide temporary coverings where insulation will be subject Co abuse and ‘cannot be concealed and protected by permanent construction, Clean spillage and soiling from adjacent construction using cleaning agents and procedures recoramended by manufacturer of affected construction END OF SECTION 071416 COLD PLUID-APPLIED WATERPROOFING Was-9 Maz SageD, ‘SECTION 071616 - CRYSTALLINE WATERPROOFING PART 1 - GENERAL Li 13 ‘RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary ‘Conditions and Division 01 Specification Sections, apply to this Section. SUMMARY Section includes crystalline waterproofing for positive negative-side application to concrete ‘and conerete unit masonry, Related Sections: 1. Division 03 Section °Cast-in-Place Concrete" for waterstops, concrete slabs serving 4s floor toppings to protect waterproofing, and finishing concrete walls and slabs t0 receive waterproofing. 2. Division 04 Section "Concrete Unit Masonry" for construction cleaning of concrete unit masonry walls to receive waterproofing. 3. Division 7 Section “Joint Sealants” for elastomeric and preformed sealants in concrete and concrete unit masonry walls anc floors. 4, Division 09 Section "Portland Cement Plastering” for plaster finishes to be applied over waterproofing. SUBMITTALS Product Data: For each type of product indicaed. Include construction deals, material descriptions and installation instructions for crystalline waterproofing. (Qualification Data: For Applicator. Product Certificates: For wauegproofing, patching, and plugging materials, from manufacturer Product Test Repors: Based on evaluation of comprehensive tests performed by manufacturer and witnessed by a qualified testing agency, fr crystalline watesproofing, Field quality-control reports, QUALITY ASSURANCE, Applicator Qualifications: A firm experienced in applying crystalline waterproofing similar in material, design, and extent to that indicated for tis Project, whose work has eesulted in applications with a record of successful in-service performance, al that employs workers ‘rained and approved by manufactu ‘CRYSTALLINE WATERPROOFING WiGIe-T ae | MB. SAEED RASHED AJTAB! RESIDENTIAL VILLA Evora B. Mockups: Provide mockups to verify selections made under sample submittals and to demonstrate aesthetic effects and set quality suandards for materials and execution, 1. Build mockup of typical vertical horizontal surfaces shown on Drawings 0.9 39, m in size. 2. Approval of mockups does not constitute approval of deviations from the Contract Documents contained in mockups unless Architect specifically approves such deviations in writing 3. Approved mockups may become part ofthe completed Work i Substantial Completion. ©. Preinstallation Conference: Conduct conference at Project site LS PROJECT CONDITIONS A. Weather Limitations: Proceed with application only when existing anc forecasted weather ‘conditions permit crystalline waterproofing to be performed according to manufacturer's written instructions. B. Proceed with waterproofing work only after pipe sleeves, ven, curbs, insets, drains, and ‘ther projections through the sudstate to be waterproofed have been completed. Proceed only ater substrate defects, including honeycombs, voids, and eracks, have been repaired 10 provide a sound subsite fre of forming materials, including reveal inserts C. Ambient Conditions: Proceed with waterproofing work only if temperature is maintained at 4.4 deg C 0 above during work and cure period, and space is well ventilated and kept free of water. PART2- PRODUCTS: 2.1 WATERPROOFING MATERIALS AL Crystalline Waterpro Prepackaged, gray-colored proprietary blend of portland jeement, specially eared sand, and active chemicals that, when mixed with water and ‘ppl, posal in ont and cont unt nan and ence chencaly Wid he | byproducts of cement hydration in the presence of water to develop crystalline growth within substrate capillaries to produce an impervious, dense, waterproof substrate; that bas VOC content complying with limits of authorities having jurisdiction; with properties meeting or exceeding the criteria specified below. 1. Products: Subject to compliance with requirements, available products that may be ineorporated into the Work include, but are not limited to, the following: Anti-Hydro Intemational, Iac.; A-H Hydrocap. BASF Building Systems; Tegraproof. Buelid Tamms; HEYDI K-11. Gemite Products fne.; Cem-Kore CW Pls. Intemational Chema-Crete, Ine.; Chem-Cretex Cem 600. Kryton Group of Companies (The); Keystol TI & T2 Waterproofing System. Xypex Chemical Corporation; Xypex. ersense ‘CRYSTALLINE WATERPROOFING OF1GS-Z 2.2 A » 23 A ORSeiaa 2. Water Permeability: Maximum zero for water at 9m when (ested according «© CECRD-C 48, 3. Compressive Strength: Minimum 27,6 MPa at 28 days when tested according «© ASTM C 109/C 109M, ACCESSORY MATERIALS Patching Compound: Factory-premixed cementitious repair mortar, crack filler, or sealant recommended by waterproofing manufacturer for filling and patching tie holes, bhoneycombs, reveals, and other itaperfections; compatible with substrate and other materials indicated; and VOC content complying with limits of authorities having jurisdiction Portland Cement: ASTM C 150, Type I Sand: ASTM C 144. Polymer Admixture for Protective Topping: Polymer bonding agent and admixture signed to improve adhesion to prepared substrates and not to este a vapor barrier Water: Potnble. MIXES Crystalline Waterproofing: Add prepackaged dry ingredients wo water according to ‘manufacturer's written instructions. Mix together with mechanical mixer or by hand (0 requited consistency. PART 3 - EXECUTION 31 A B. c. 32 A B. c. EXAMINATION [Examine substrates, areas, and conditions, with Applicator present, for suitable conditions ‘where waterproofing isto be applied. Proceed with application only after unsatisfactory conditions have been corrected Notify Architect in writing of active leaks or defects that would affect system peeformance. PREPARATION Protect other work from damage caused by cleaning, preparation, and application of \aterprooting. Provide temporary enclosure to confine spraying operation and to ensure iadequate ambient cemperatures and vertilaion conditions for spplication, Do not allow waterproofing, patching, anc plugging materials co enter reveals or annular spaces intended for resilient sealants or gaskets, such as joint spaces between pipes and pipe sleeves. ‘Stop active water leaks with plugging compound according to waterproofing manufacturer's ‘written instructions. CRYSTALLINE WATERPROOFING 7161-3 MB. SASED RASHED AJTABI RESIDENTIAL VILLA 33 D, cesealas g Repair damaged or unsatisfactory substrate with patching compound according to ‘manufacturer's writen instructions. L.A boles and cracks in substrate, remove loosened chips and eut reveal with sides perpendicular to surface, not tapered, and approximately 25.4 mm deep. Fill reveal ‘with patching compound flush with surface, Surface Preparation: Comply with waterproofing manufacturer's written instructions to remove efflorescence, chalks, dust, dit, mortar spatter, grease, oils, paint, curing compounds, and form-release agents to ensure that waterproofing bonds 10 surfaces. 1. Clean concrete surfaces according to ASTM D 4258, a. Prepare smooth-formed and towel-inished concrete by mechanical sbrading. or abrasive-blast cleaning according to ASTM D 4259, 2. Clean conerete unit masonry surfaces according to ASTM D 4261. 8, Medium and Normal-Weight Concrete Unit Masonry: Sandblast or bushhammer to a depth of 1.6 mm. Concrete Joints: Clean reveals according to waterproofing manufacturer's written instructions. APPLICATION General: Comply with waterproofing manulacturer’s written instructions for application and curing L. — Saturate surface with water for several hours prior to application and maintain damp condition until applying waterproofing. Remove standing water. Apply waterproofing to surfaces indicated on Drawings Number of Coats: Number required for specified’ water permeability Three. Application Method: Brush Spray, Apply to ensure that each coat fills voids and is in full contact with substrate or previous coat 5. Dampen surface between coats, Final Coat Finish: Smooth Brushed Spray Textured. Curing: Moist-cure waterproofing for three days immediately after final coat has set, followed by air drying, unless otherwise recommended in writing by manufacturer, ‘Waterproofing Treatment Extensions: Extend waterproofing treatment as follows’ 1, Onto columns integral with created walls 2. Onto interior nontreated walls intersecting exterior treated walls, for a distance of 600 sm for cast-in-place concrete anc) 1200 mm for mason. 3. Onto exterior walls and onto both exterior and interior colurnns, for a height of 300 ‘nim, where floors, but not walls are treated. 4. Onio every subsizate in areas indicated for treatment, including pipe trenches pipe chases pits sumps and similar offsets and features, ‘CRYSTALLINE WATERPROOFING Wisi6-4 MR, SAEED RASHED AJTAS! RESIDENTIAL VILLA 34 FIELD QUALITY CONTROL, A. Inspection: Engage manufacturer's representative to inspect completed application and provide a written report that application complies with manufacturer's written instructions, END OF SECTION 071616 CRYSTALLINE WATERPROOFING 161-5 i 1 i i | nese |sa ! | a { | | | (@) DEANAGELAYOUT SERVICE BLOCKLOOR FLA ‘i | suas | i i 1 } 1 4 i i i 1 i i | i | ~ HECHANICAL DRAWINGS (@-BPANAGE LAYOUT. SERVICE BLOCK ROOF PLAN ——— DRANGAE | Te ro LAYOUT-SERVICE BLOCK "Vila or Saeed Rashed ‘abi usa UAE ~ "WECHANIGAL DRAWINGS j DRAINAGE LAYOUT - ROOF FLOORPLAN

You might also like