DATA SHEET SHEET 1 OF 2
PDVSA DUAL POLARITY ELECTROSTATIC DEHYDRATOR (AC/DC)
‘GLENT: POVSA EGUIPWENT: ELECTROSTATIC DEAYDRATOR QTY: ONE @
PROJECT N" ODE: DE-t01/704
DEHYDRATION PLANT UNFT SERVICE: WET CRUDE srawe: ves
LOCATION: JUSEPINEPJUS-2 PRESSURE VESSEL DESIGN: PER ASME CODE SECTION DV. +
‘TYPE: HORIZONTAL BSE, HEADS! 2:1 SLLIPTICAL
oie) 120K 4s" 5/5
C PROCESS = CHARACTERISTICS OF THE FLUIOS (NOTE #15)
CRUDE CHARACTERISTICS: WATER CHARACTERISTICS:
MAXIMUM FLOW (MED): co MAXIMUM FL
VISCOSITY @T = 140°F (py 609 VISCOSITY @T
DENSITY @ T=140"F (iba): DENSITY @ T=140°F (ts)
SP. GRAVITY@ T=140°F SP. GRAVITY@ T=140°F
GRAVITY CAP), 28.0
MAX. % WS INVOL. (CRUDE OUTLET: 07
FOAM FORMATION: MODERATE,
MECHANICAL — OBERATING [DESIGN / CONDITIONS/NSPECTION AND TESTS
DESIGN PRESSURE (psig ay Fabricator 12.5 PSIG
DESIGN TEMPERATURE ('F) By Fabricator 210 °F
TOTAL HANDLING CAPACITY (MBD} 86
OPERATING PRESSURE (pig): 60
MAX. OPERATING TEMP. CF) 165
NORMAL LEVEL INTERFACE (in): 20
MAX. WATER DEHYDRATOR INLET: 30
SHELL THICKNESS (I NOTES 1&2
HEAD THICKNESS (in) NOTES 182
CORROSION TOLERANCE SHELL (h}: ‘Ve min,
(CORROSION TOLERANCE HEADS (mn) amin,
(CORROSION TOLERANCE NOZZLES (in): ve min,
L “TESTS AND INSPECTION REGURED FOR WELDED CONNECTIONS: 1
MAGNETIC PARTICLE: YES / PER ASME CODE LIQUID PENETRANT: YES / PER ASME CODE
RADIOGRAPHY: | YES/PER ASME CODE (106% RT2 ULTRASONIC: YES/ PER ASME CODE
STRESS RELIEF: ¥E6/PER ASME CODE WOT RE@D. PREHEAT: YES/ PER ASME CODE
WIND LOAD: "PER ASME AND PDVSA NORMS ‘SEISMIC LOAD: PER PDVSA JA-222, Zone 5
HYDROSTATIC TEST (psig): YES / PER ASME CODE PNEUMATIC TEST REINF. PADS: Yes, Per Code
MATERIAL CERTIFICATION REQUIRED: YES.
WEIGHT (bs): EMPTY: BY FABRIGATOR FILLED WITH WATER: BY FABRICATOR
OPERATING: BY FABRICATOR
[ rrr OTE 1
SHELL ASTM A516-70 or SIMILAR SUPPORTS (SKIRT): _-ASTMAST670 oesiALAR
READS ‘ASTM &-516-70 or SIMLAR FLANGES: ‘ASTM A105 or SMLAR.
Nozzles: ASTMALO60 or SIMILAR Nes ‘ASTM AOS or SIMILAR.
GASKETS: SPIRAL WOUND 308 SS, of Aabestos,
INTERNAL B0LTSANUTS "ASTI At03 Gr BEM (TYPE 316) or SIMILAR
EXTERNAL BOLTSINUTS: ‘ASTI At99 Gr BT AND A tou Gea
STANDPPE SUPPORTRINGS: YES PER ASME CODE
[ = PANT TCORTINS 1
PAINT PER PDVSA 0-201 FOR NORMAL INDUSTRIAL ENVIRONVENT
: SOLID COATING FOR HEAT CONSERVATION (NOT HYGROSCOPIC)
‘COVERED WITH ALUMINUM JACKETING ~PER POVSA STANDARD 0-201
INTERNAL:
NONE REQD, PER PDYSA| DATA SHEET
PDVSA | oun. rotanryevecNA MEET sropatoR aco) | SHEET? OF 2
} J
= —THECHANICAL=NOZZLES OTE)
ARK ay SE Cass | FACE: SERIE
2 Nt 1 10" 450_ RE CRUDE INLET
= x io 160] RF | CRUDE OUTLET
TAB z “ 160_—| RF | WATER OUTLET
TaAerob—[ Sait RE [INTERFACE DRAW
TEABODIEE [6 160 RE SAND DRAW.
NeNECDEE [6 [180] "RF SAND JET INLET
Nr = 10 RE] RELIEF AND VENT
NE 1 166 RF VAPOR OUTLET.
TA 2 460 RE | DXSHA/ XSL
moe]? re 480 Re | LeveL GAGE
MAS 2 6 10 ‘Re | TRANSMIT TERT PRESSURE NDIGRTOR
naa 2a 450 Re aay
na] 4 2 450 RF | MEASURING PRIMARY ELEMENT
Meas je 150 RE HIGH VOLTAGE WIRE CONNECTION
- INSTRUNENTATION NOTE 3p SUPPLEDBY
: am FAERIGATOR | OTHERS
RELIEF VALVE —— x
OIL OUTLET FLOW TRANSMITTER INOTE 7] x
WATER OUTLET FLOW TRANSMITTER (NOTE 1 x
LEVEL SWITCH x
LEVEL GAUGE (6 :
"TENPERATURS INDICATOR TRANSHITTER NOTE 72) x
[ WATER /OIL ANALYZER x
OIL OUTLET ORIFICE PLATE CONTROL VALVE x
WATER OUT ORIFICE PLATE /LEVEL CONTROL VALVE! x
INTERFACE LEVEL CONTROLLER TRANSMITTER x
i NOTES
1 EQUIPMENT DESIGNED IN ACCORDANCE WITH LATEST EDITION OF ASME CODE SEC. Vil, DIV. 4
2 TOBE DEFINED BY EQUIPMENT FABRICATOR
3. ALL DIMENSIONS IN MM, UNLESS OTHER UNIT OF MEASUREMENT IS INDICATED OTHERWISE
4 ALL DIMENSIONS REFER TO THE TANGENTIAL LINE OF THE EQUIPMENT.
5. REFERENCE DOCUMENTS (ELECTROSTATIC DEHYDRATOR SPECIFICATION No. 00012-18000-
9685000),
6. _EQUIPNENT SHALL HAVE AT LEAST TWO (2) GROUNDING LUGS, ONE ON EACH SADDLE
T. POWER SUPPLY FOR EQUIPMENT SHALL BE ACIDC TRANSFORMER 150 KVA 480 V PRIMARY
8. ALL MANWAYS SHALL HAVE DAVITS
9. THESE ARE THE MINIMUM MECHANICAL REQUIREMENTS FOR ACCESSORIES.
40, EQUIPMENT TO HAVE GRATING TYPE VORTEX BREAKER AT OIL OUTLET NOZZLE
11. MAXIMUM VALUES ALLOWED BY PDVSA FOR THE DESIGN PRESENTED BY THE FABRICATOR
12. READING IN MULTLVARIABLE MEASURING EQUIPMENT.
33. THESE ARE THE MINIMUM INSTRUMENTATION REQUIREMENTS
14 EQUIPMENT PROVIDED WITH LADDER, PLATFORM AND FIREPROOF CLIPS
18. SEELADDER / PLATFORM REQUIREMENTS.
46. INCLUDE LIFTING LUGS BY FABRICATOR.
17. THE CONFIRMATION OF THE DATA IS THE RESPONSIBILITY OF THE FABRICATOR
18. _ EFFLUENT WATER STREAM <= 300 ppm OF SUSPENDED INSOLUBLE CRUDE