You are on page 1of 25

148.

0 ft

DESIGNED APPURTENANCE LOADING

Lighthing
152
150
137
(12)
122
Pirod
107
DB874H
15' Low
Rod 5/8x4'
Profile Rotable
Platform

2.3

29.586

22.000

18

0.219

37.000

TYPE

ELEVATION

TYPE

ELEVATION

Lighthing Rod 5/8x4'


(12) DB874H
Pirod 15' Low Profile Rotable
Platform

152
150
150

(12) DB874H
Pirod 15' Low Profile Rotable
Platform

122
122

(12) DB874H

137

107
107

Pirod 15' Low Profile Rotable


Platform

137

(12) DB874H
Pirod 15' Low Profile Rotable
Platform

MATERIAL STRENGTH
GRADE
A572-65

3.750

5.3

43.307

A572-65

3.5

36.580

28.380
35.106

Tower designed for a 85 mph basic wind in accordance with the TIA/EIA-222-F Standard.
Tower is also designed for a 74 mph basic wind with 0.50 in ice.
Deflections are based upon a 50 mph wind.
TOWER RATING: 99.3%

74.8 ft

5.500

18

0.313

YIELD

TOWER DESIGN NOTES


1.
2.
3.
4.

111.0 ft

4.750

18

0.250

40.000

40.000
3

GRADE

65 ksi

39.5 ft

SHEAR
23 K

8.4

50.780

18

0.375

41.554

AXIAL
38 K

45.000
4

YIELD

MOMENT
2542 kip-ft

19.5

0.0 ft

REACTIONS - 85 mph WIND

Weight (K)

Grade

Bot Dia (in)

Top Dia (in)

Lap Splice (ft)

Thickness (in)

Number of Sides

Length (ft)

Section

74 mph WIND - 0.500 in ICE


AXIAL
32 K
MOMENT
3001 kip-ft
SHEAR
27 K

Computerized Structural
8989 N. Port Washington Road
Milwaukee, WI 53217
Consulting Engineers

Phone: (414) 351-5588


FAX: (414) 351-4617

Job:

Example #2

Project: Summit
Client:
Code:
Path:

Pole
CSD
TIA/EIA-222-F

Drawn by:

App'd:

Date:

Scale:

horn
07/15/03

C:\MSDEV\PROJECTS\ERITower\Debug\benchmarks\summitpole.eri

NTS
E-1

Dwg No.

148.0 ft

DESIGNED APPURTENANCE LOADING

Lighthing
152
150
137
(12)
122
Pirod
107
DB874H
15' Low
Rod 5/8x4'
Profile Rotable
Platform

2.3

29.586

22.000

18

0.219

37.000

TYPE

ELEVATION

TYPE

ELEVATION

Lighthing Rod 5/8x4'


(12) DB874H
Pirod 15' Low Profile Rotable
Platform

152
150
150

(12) DB874H
Pirod 15' Low Profile Rotable
Platform

122
122

(12) DB874H

137

107
107

Pirod 15' Low Profile Rotable


Platform

137

(12) DB874H
Pirod 15' Low Profile Rotable
Platform

MATERIAL STRENGTH
GRADE
A572-65

3.750

5.3

43.307

A572-65

3.5

36.580

28.380
35.106

Tower designed for a 85 mph basic wind in accordance with the TIA/EIA-222-F Standard.
Tower is also designed for a 74 mph basic wind with 0.50 in ice.
Deflections are based upon a 50 mph wind.
TOWER RATING: 99.3%

74.8 ft

5.500

18

0.313

YIELD

TOWER DESIGN NOTES


1.
2.
3.
4.

111.0 ft

4.750

18

0.250

40.000

40.000
3

GRADE

65 ksi

39.5 ft

SHEAR
23 K

8.4

50.780

18

0.375

41.554

AXIAL
38 K

45.000
4

YIELD

MOMENT
2542 kip-ft

19.5

0.0 ft

REACTIONS - 85 mph WIND

Weight (K)

Grade

Bot Dia (in)

Top Dia (in)

Lap Splice (ft)

Thickness (in)

Number of Sides

Length (ft)

Section

74 mph WIND - 0.500 in ICE


AXIAL
32 K
MOMENT
3001 kip-ft
SHEAR
27 K

Computerized Structural
8989 N. Port Washington Road
Milwaukee, WI 53217
Consulting Engineers

Phone: (414) 351-5588


FAX: (414) 351-4617

Job:

Example #2

Project: Summit
Client:
Code:
Path:

Pole
CSD
TIA/EIA-222-F

Drawn by:

App'd:

Date:

Scale:

horn
07/15/03

C:\MSDEV\PROJECTS\ERITower\Debug\benchmarks\summitpole.eri

NTS
E-1

Dwg No.

Page

Job

ERITower

1 of 13

Example #2
Project

Computerized Structural

Date

Summit Pole

8989 N. Port Washington Road


Milwaukee, WI 53217
Phone: (414) 351-5588
FAX: (414) 351-4617

16:40:05 07/15/03

Client

Designed by

CSD

horn

Tower Input Data


There is a pole section.
This tower is designed using the TIA/EIA-222-F standard.
The following design criteria apply:
Basic wind speed of 85 mph.
Nominal ice thickness of 0.500 in.
Ice density of 56 pcf.
A wind speed of 74 mph is used in combination with ice.
Deflections calculated using a wind speed of 50 mph.
A non-linear (P-delta) analysis was used.
Pressures are calculated at each section.
Stress ratio used in pole design is 1.333.
Local bending stresses due to climbing loads and feedline supports are not considered

Options
Consider Moments - Legs
Consider Moments - Horizontals
Consider Moments - Diagonals
Use Moment Magnification
v Use Code Stress Ratios
v Use Code Safety Factors - Guys
Escalate Ice
Always Use Max Kz
Use Special Wind Profile

Distribute Leg Loads As Uniform


Assume Legs Pinned
Assume Rigid Index Plate
Use Clear Spans For Wind Area
Use Clear Spans For KL/r
Retension Guys To Initial Tension
v Bypass Mast Stability Checks
Use Azimuth Dish Coefficients
Project Wind Area of Appurt.
Autocalc Torque Arm Areas

Treat Feedline Bundles As Cylinder


Use ASCE 10 X-Brace Ly Rules
v Calculate Redundant Bracing Forces
Consider Feedline Torque
v SR Leg Bolts Resist Compression
v All Leg Panels Have Same Allowable
Offset Girt At Foundation
Poles
Include Shear-Torsion Interaction
Always Use Sub-Critical Flow
Use Top Mounted Sockets

Tapered Pole Section Geometry


Section

Elevation

Section
Length
ft
37.000

Splice
Length
ft
3.750

Number
of
Sides
18

Top
Diameter
in
22.000

Bottom
Diameter
in
29.586

Wall
Thickness
in
0.219

Bend
Radius
in
0.875

40.000

4.750

18

28.380

36.580

0.250

1.000

5.500

18

35.106

43.307

0.313

1.250

18

41.554

50.780

0.375

1.250

L2

ft
148.000111.000
111.000-74.750

L3

74.750-39.500

40.000

L4

39.500-0.000

45.000

L1

Pole Grade
A572-65
(65 ksi)
A572-65
(65 ksi)
A572-65
(65 ksi)
A572-65
(65 ksi)

Tapered Pole Properties


Section
L1

Tip Dia.
in
22.339
30.042

Area
in2
15.123
20.390

I
in4
906.444
2221.684

r
in
7.732
10.425

C
in
11.176
15.030

I/C
in3
81.106
147.820

J
in4
1814.080
4446.291

It/Q
in2
7.563
10.197

w
in
3.487
4.822

w/t
15.941
22.044

Project

L2
L3
L4

Area
in2
22.321
28.828
34.511
42.645
49.014
59.995

Date

Summit Pole

8989 N. Port Washington Road


Milwaukee, WI 53217
Phone: (414) 351-5588
FAX: (414) 351-4617

Tip Dia.
in
29.598
37.144
36.637
43.975
43.340
51.563

2 of 13

Example #2

Computerized Structural

Section

Page

Job

ERITower

16:40:05 07/15/03

Client

Designed by

CSD

I
in4
2231.399
4807.071
5278.330
9959.398
10500.631
19257.349

Tower
Elevation

Gusset
Area
(per face)

Gusset
Thickness

ft
L1 148.000111.000
L2 111.00074.750
L3 74.75039.500
L4 39.5000.000

ft2

in

r
in
9.986
12.897
12.352
15.263
14.619
17.894

C
in
14.417
18.583
17.834
22.000
21.110
25.796

I/C
in3
154.777
258.686
295.971
452.701
497.433
746.518

Gusset Grade Adjust. Factor


Af

horn

J
in4
4465.735
9620.468
10563.605
19931.901
21015.079
38540.037

Adjust.
Factor
Ar

It/Q
in2
11.163
14.417
17.259
21.327
24.512
30.003

w
in
4.555
5.998
5.629
7.072
6.742
8.365

w/t
18.219
23.992
18.012
22.631
17.978
22.307

Weight Mult. Double Angle Double Angle


Stitch Bolt
Stitch Bolt
Spacing
Spacing
Diagonals
Horizontals
in
in
1.01

1.03

1.03

1.01

1.03

1.01

1.03

1.01

Feed Line/Linear Appurtenances - Entered As Area


Description

Face

Allow
Shield

Component
Type

Placement

Total
Number

7/8

No

Inside Pole

ft
148.000 - 0.000

12

7/8

No

Inside Pole

137.000 - 0.000

12

7/8

No

Inside Pole

122.000 - 0.000

12

7/8

No

Inside Pole

107.000 - 0.000

12

No Ice
1/2'' Ice
1'' Ice
2'' Ice
4'' Ice
No Ice
1/2'' Ice
1'' Ice
2'' Ice
4'' Ice
No Ice
1/2'' Ice
1'' Ice
2'' Ice
4'' Ice
No Ice
1/2'' Ice
1'' Ice
2'' Ice
4'' Ice

CAAA

Weight

klf
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001
0.001

ft /ft
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000

Feed Line/Linear Appurtenances Section Areas


Tower
Section
L1

Tower
Elevation
ft
148.000-111.000

L2

111.000-74.750

Face
A
B
C
A

AR

AF

ft
0.000
0.000
0.000
0.000

ft
0.000
0.000
0.000
0.000

CAAA
In Face
ft2
0.000
0.000
0.000
0.000

CAAA
Out Face
ft2
0.000
0.000
0.000
0.000

Weight
K
0.000
0.000
0.480
0.000

Project

L3

74.750-39.500

L4

39.500-0.000

Date

Summit Pole

8989 N. Port Washington Road


Milwaukee, WI 53217
Phone: (414) 351-5588
FAX: (414) 351-4617

Tower
Elevation
ft

3 of 13

Example #2

Computerized Structural

Tower
Section

Page

Job

ERITower

16:40:05 07/15/03

Client

Designed by

CSD

Face

AR

AF

B
C
A
B
C
A
B
C

ft2
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000

ft2
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000

CAAA
In Face
ft2
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000

horn

CAAA
Out Face
ft2
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000

Weight
K
0.000
0.914
0.000
0.000
0.914
0.000
0.000
1.024

Feed Line/Linear Appurtenances Section Areas - With Ice


Tower
Section
L1

Tower
Elevation
ft
148.000-111.000

L2

111.000-74.750

L3

74.750-39.500

L4

39.500-0.000

Face
A
B
C
A
B
C
A
B
C
A
B
C

Ice
Thickness
in
0.500
0.500
0.500
0.500

AR

AF

ft2
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000

ft2
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000

CAAA
In Face
ft2
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000

CAAA
Out Face
ft2
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000

Weight
K
0.000
0.000
0.480
0.000
0.000
0.914
0.000
0.000
0.914
0.000
0.000
1.024

Discrete Tower Loads


Description

Face
or Leg

Offset
Type

Lighthing Rod 5/8x4'

(12) DB874H

Offsets:
Horz
Lateral
Vert
ft

Azimuth
Adjustment

Placement

None

deg
0.000

ft
152.000

None

0.000

150.000

Pirod 15' Low Profile Rotable


Platform

None

0.000

150.000

(12) DB874H

None

0.000

137.000

No Ice
1/2'' Ice
1'' Ice
2'' Ice
4'' Ice
No Ice
1/2'' Ice
1'' Ice
2'' Ice
4'' Ice
No Ice
1/2'' Ice
1'' Ice
2'' Ice
4'' Ice
No Ice
1/2'' Ice
1'' Ice
2'' Ice

CAAA
Front

CAAA
Side

Weight

ft2
0.250
0.664
0.973
1.494
2.683
5.600
6.190
6.780
7.960
10.320
20.600
25.200
29.800
39.000
57.400
5.600
6.190
6.780
7.960

ft2
0.250
0.664
0.973
1.494
2.683
5.600
6.190
6.780
7.960
10.320
20.600
25.200
29.800
39.000
57.400
5.600
6.190
6.780
7.960

K
0.031
0.034
0.039
0.059
0.137
0.015
0.047
0.079
0.143
0.271
2.050
2.325
2.600
3.150
4.250
0.015
0.047
0.079
0.143

4 of 13

Example #2
Project

Computerized Structural

Face
or Leg

Date

Summit Pole

8989 N. Port Washington Road


Milwaukee, WI 53217
Phone: (414) 351-5588
FAX: (414) 351-4617

Description

Page

Job

ERITower

16:40:05 07/15/03

Client

Designed by

CSD

Offset
Type

Offsets:
Horz
Lateral
Vert
ft

horn

Azimuth
Adjustment

Placement

CAAA
Front

CAAA
Side

Weight

deg

ft

ft2
10.320
20.600
25.200
29.800
39.000
57.400
5.600
6.190
6.780
7.960
10.320
20.600
25.200
29.800
39.000
57.400
5.600
6.190
6.780
7.960
10.320
20.600
25.200
29.800
39.000
57.400

ft2
10.320
20.600
25.200
29.800
39.000
57.400
5.600
6.190
6.780
7.960
10.320
20.600
25.200
29.800
39.000
57.400
5.600
6.190
6.780
7.960
10.320
20.600
25.200
29.800
39.000
57.400

K
0.271
2.050
2.325
2.600
3.150
4.250
0.015
0.047
0.079
0.143
0.271
2.050
2.325
2.600
3.150
4.250
0.015
0.047
0.079
0.143
0.271
2.050
2.325
2.600
3.150
4.250

Pirod 15' Low Profile Rotable


Platform

None

0.000

137.000

(12) DB874H

None

0.000

122.000

Pirod 15' Low Profile Rotable


Platform

None

0.000

122.000

(12) DB874H

None

0.000

107.000

Pirod 15' Low Profile Rotable


Platform

None

0.000

107.000

4'' Ice
No Ice
1/2'' Ice
1'' Ice
2'' Ice
4'' Ice
No Ice
1/2'' Ice
1'' Ice
2'' Ice
4'' Ice
No Ice
1/2'' Ice
1'' Ice
2'' Ice
4'' Ice
No Ice
1/2'' Ice
1'' Ice
2'' Ice
4'' Ice
No Ice
1/2'' Ice
1'' Ice
2'' Ice
4'' Ice

Tower Pressures - No Ice


GH = 1.690
Section
Elevation

KZ

qz

AG
ft2
79.528

ft
L1 148.000111.000

ft
128.781

1.476

ksf
0.027

L2 111.00074.750

92.445

1.342

0.025

99.277

L3 74.75039.500

56.982

1.169

0.022

116.600

L4 39.5000.000

19.180

0.018

153.823

F
a
c
e
A
B
C
A
B
C
A
B
C
A
B
C

AF
ft2
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000

AR
ft2
81.914
81.914
81.914
102.256
102.256
102.256
120.098
120.098
120.098
158.438
158.438
158.438

Aleg
ft2
81.914
102.256
120.098
158.438

Leg
%
100.00
100.00
100.00
100.00
100.00
100.00
100.00
100.00
100.00
100.00
100.00
100.00

CAAA
In
Face
ft2
0.000

CAAA
Out
Face
ft2
0.000

0.000

0.000

0.000

0.000

0.000

0.000

Page

Job

ERITower

5 of 13

Example #2
Project

Computerized Structural

Date

Summit Pole

8989 N. Port Washington Road


Milwaukee, WI 53217
Phone: (414) 351-5588
FAX: (414) 351-4617

16:40:05 07/15/03

Client

Designed by

CSD

horn

Tower Pressure - With Ice


GH = 1.690
Section
Elevation

KZ

qz

tZ

AG

in
0.500

ft
L1 148.000111.000

ft
128.781

1.476

ksf
0.021

L2 111.00074.750

92.445

1.342

0.019

0.500

L3 74.75039.500

56.982

1.169

0.016

0.500

L4 39.500-0.000

19.180

0.014

0.500

F
a
c
2
ft
e
82.612 A
B
C
102.298 A
B
C
119.537 A
B
C
157.114 A
B
C

AF

AR

Aleg

Leg
%

ft2
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000

ft2
85.090
85.090
85.090
105.367
105.367
105.367
123.123
123.123
123.123
161.828
161.828
161.828

ft2
85.090
105.367
123.123
161.828

100.00
100.00
100.00
100.00
100.00
100.00
100.00
100.00
100.00
100.00
100.00
100.00

CAAA
In
Face
ft2
0.000

CAAA
Out
Face
ft2
0.000

0.000

0.000

0.000

0.000

0.000

0.000

Tower Pressure - Service


GH = 1.690
Section
Elevation

KZ

qz

AG

ft
L1 148.000111.000

ft
128.781

1.476

ksf
0.009

ft2
79.528

L2 111.00074.750

92.445

1.342

0.009

99.277

L3 74.75039.500

56.982

1.169

0.007

116.600

L4 39.5000.000

19.180

0.006

153.823

F
a
c
e
A
B
C
A
B
C
A
B
C
A
B
C

ft2
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000

Leg
%

Aleg

AR

AF

ft2
81.914

ft2
81.914
81.914
81.914
102.256
102.256
102.256
120.098
120.098
120.098
158.438
158.438
158.438

102.256
120.098
158.438

100.00
100.00
100.00
100.00
100.00
100.00
100.00
100.00
100.00
100.00
100.00
100.00

CAAA
In
Face
ft2
0.000

CAAA
Out
Face
ft2
0.000

0.000

0.000

0.000

0.000

0.000

0.000

Tower Forces - No Ice - Wind Normal To Face


Section
Elevation

Add
Weight

Self
Weight

ft
L1 148.000111.000

K
0.480

K
2.258

L2 111.000-

0.914

3.516

F
a
c
e
A
B
C
A

CF

1
1
1
1

0.65
0.65
0.65
0.65

RR

DF

1
1
1
1

DR

1
1
1
1

AE

1
1
1
1

ft2
81.914
81.914
81.914
102.256

Ctrl.
Face

2.453

klf
0.066

2.784

0.077

8989 N. Port Washington Road


Milwaukee, WI 53217
Phone: (414) 351-5588
FAX: (414) 351-4617

ft
74.750

6 of 13

Example #2

Computerized Structural

Section
Elevation

Page

Job

ERITower

Add
Weight

Self
Weight

L3 74.75039.500

0.914

5.303

L4 39.5000.000

1.024

8.429

Sum Weight:

3.331

19.507

Project

Date

Summit Pole

16:40:05 07/15/03

Client

Designed by

CSD

F
a
c
e
B
C
A
B
C
A
B
C

CF

1
1
1
1
1
1
1
1

RR

0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65

DF

1
1
1
1
1
1
1
1

horn

DR

1
1
1
1
1
1
1
1

AE

1
1
1
1
1
1
1
1
OTM

ft2
102.256
102.256
120.098
120.098
120.098
158.438
158.438
158.438
796.848
kip-ft

klf

Ctrl.
Face

2.840

0.081

3.219

0.081

11.296

Tower Forces - No Ice - Wind 60 To Face


Section
Elevation

Add
Weight

Self
Weight

ft
L1 148.000111.000

K
0.480

K
2.258

L2 111.00074.750

0.914

3.516

L3 74.75039.500

0.914

5.303

L4 39.5000.000

1.024

8.429

Sum Weight:

3.331

19.507

F
a
c
e
A
B
C
A
B
C
A
B
C
A
B
C

CF

1
1
1
1
1
1
1
1
1
1
1
1

RR

0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65

DF

1
1
1
1
1
1
1
1
1
1
1
1

DR

1
1
1
1
1
1
1
1
1
1
1
1

AE

1
1
1
1
1
1
1
1
1
1
1
1
OTM

ft2
81.914
81.914
81.914
102.256
102.256
102.256
120.098
120.098
120.098
158.438
158.438
158.438
796.848
kip-ft

Ctrl.
Face

2.453

klf
0.066

2.784

0.077

2.840

0.081

3.219

0.081

11.296

Tower Forces - No Ice - Wind 90 To Face


Section
Elevation

Add
Weight

Self
Weight

ft
L1 148.000111.000

K
0.480

K
2.258

L2 111.00074.750

0.914

3.516

L3 74.75039.500

0.914

5.303

L4 39.5000.000

1.024

8.429

F
a
c
e
A
B
C
A
B
C
A
B
C
A
B

CF

1
1
1
1
1
1
1
1
1
1
1

0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65

RR

DF

1
1
1
1
1
1
1
1
1
1
1

DR

1
1
1
1
1
1
1
1
1
1
1

AE

1
1
1
1
1
1
1
1
1
1
1

ft2
81.914
81.914
81.914
102.256
102.256
102.256
120.098
120.098
120.098
158.438
158.438

Ctrl.
Face

2.453

klf
0.066

2.784

0.077

2.840

0.081

3.219

0.081

8989 N. Port Washington Road


Milwaukee, WI 53217
Phone: (414) 351-5588
FAX: (414) 351-4617

Section
Elevation

Add
Weight

Self
Weight

ft

3.331

7 of 13

Example #2

Computerized Structural

Sum Weight:

Page

Job

ERITower

Project

Date

Summit Pole

16:40:05 07/15/03

Client

Designed by

CSD

F
a
c
e
C

CF

RR

0.65

DF

DR

19.507

1
OTM

horn

AE
ft2
158.438
796.848
kip-ft

klf

Ctrl.
Face

11.296

Tower Forces - With Ice - Wind Normal To Face


Section
Elevation

Add
Weight

Self
Weight

ft
L1 148.000111.000

K
0.480

K
2.858

L2 111.00074.750

0.914

4.262

L3 74.75039.500

0.914

6.178

L4 39.5000.000

1.024

9.581

Sum Weight:

3.331

22.879

F
a
c
e
A
B
C
A
B
C
A
B
C
A
B
C

CF

1
1
1
1
1
1
1
1
1
1
1
1

RR

0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65

DF

1
1
1
1
1
1
1
1
1
1
1
1

DR

1
1
1
1
1
1
1
1
1
1
1
1

1
1
1
1
1
1
1
1
1
1
1
1
OTM

AE
ft2
85.090
85.090
85.090
105.367
105.367
105.367
123.123
123.123
123.123
161.828
161.828
161.828
623.260
kip-ft

Ctrl.
Face

1.932

klf
0.052

2.174

0.060

2.206

0.063

2.492

0.063

8.804

Tower Forces - With Ice - Wind 60 To Face


Section
Elevation

Add
Weight

Self
Weight

ft
L1 148.000111.000

K
0.480

K
2.858

L2 111.00074.750

0.914

4.262

L3 74.75039.500

0.914

6.178

L4 39.5000.000

1.024

9.581

Sum Weight:

3.331

22.879

F
a
c
e
A
B
C
A
B
C
A
B
C
A
B
C

CF

1
1
1
1
1
1
1
1
1
1
1
1

0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65

RR

DF

1
1
1
1
1
1
1
1
1
1
1
1

DR

1
1
1
1
1
1
1
1
1
1
1
1

1
1
1
1
1
1
1
1
1
1
1
1
OTM

AE
ft2
85.090
85.090
85.090
105.367
105.367
105.367
123.123
123.123
123.123
161.828
161.828
161.828
623.260
kip-ft

Ctrl.
Face

1.932

klf
0.052

2.174

0.060

2.206

0.063

2.492

0.063

8.804

Page

Job

ERITower

8 of 13

Example #2

Computerized Structural
8989 N. Port Washington Road
Milwaukee, WI 53217
Phone: (414) 351-5588
FAX: (414) 351-4617

Project

Date

Summit Pole

16:40:05 07/15/03

Client

Designed by

CSD

horn

Tower Forces - With Ice - Wind 90 To Face


Section
Elevation

Add
Weight

Self
Weight

ft
L1 148.000111.000

K
0.480

K
2.858

L2 111.00074.750

0.914

4.262

L3 74.75039.500

0.914

6.178

L4 39.5000.000

1.024

9.581

Sum Weight:

3.331

22.879

F
a
c
e
A
B
C
A
B
C
A
B
C
A
B
C

CF

1
1
1
1
1
1
1
1
1
1
1
1

RR

0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65

DF

1
1
1
1
1
1
1
1
1
1
1
1

DR

1
1
1
1
1
1
1
1
1
1
1
1

AE

1
1
1
1
1
1
1
1
1
1
1
1
OTM

ft2
85.090
85.090
85.090
105.367
105.367
105.367
123.123
123.123
123.123
161.828
161.828
161.828
623.260
kip-ft

Ctrl.
Face

1.932

klf
0.052

2.174

0.060

2.206

0.063

2.492

0.063

8.804

Tower Forces - Service - Wind Normal To Face


Section
Elevation

Add
Weight

Self
Weight

ft
L1 148.000111.000

K
0.480

K
2.258

L2 111.00074.750

0.914

3.516

L3 74.75039.500

0.914

5.303

L4 39.5000.000

1.024

8.429

Sum Weight:

3.331

19.507

F
a
c
e
A
B
C
A
B
C
A
B
C
A
B
C

CF

1
1
1
1
1
1
1
1
1
1
1
1

RR

0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65

DF

1
1
1
1
1
1
1
1
1
1
1
1

DR

1
1
1
1
1
1
1
1
1
1
1
1

AE

1
1
1
1
1
1
1
1
1
1
1
1
OTM

ft2
81.914
81.914
81.914
102.256
102.256
102.256
120.098
120.098
120.098
158.438
158.438
158.438
275.726
kip-ft

Ctrl.
Face

0.849

klf
0.023

0.963

0.027

0.983

0.028

1.114

0.028

3.909

Tower Forces - Service - Wind 60 To Face


Section
Elevation

Add
Weight

Self
Weight

ft
L1 148.000111.000

K
0.480

K
2.258

L2 111.000-

0.914

3.516

F
a
c
e
A
B
C
A

CF

1
1
1
1

0.65
0.65
0.65
0.65

RR

DF

1
1
1
1

DR

1
1
1
1

AE

1
1
1
1

ft2
81.914
81.914
81.914
102.256

Ctrl.
Face

0.849

klf
0.023

0.963

0.027

Project

Add
Weight

Self
Weight

Date

Summit Pole

8989 N. Port Washington Road


Milwaukee, WI 53217
Phone: (414) 351-5588
FAX: (414) 351-4617

ft
74.750

9 of 13

Example #2

Computerized Structural

Section
Elevation

Page

Job

ERITower

16:40:05 07/15/03

Client

Designed by

CSD

L3 74.75039.500

0.914

5.303

L4 39.5000.000

1.024

8.429

Sum Weight:

3.331

19.507

F
a
c
e
B
C
A
B
C
A
B
C

CF

1
1
1
1
1
1
1
1

RR

0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65

DF

1
1
1
1
1
1
1
1

DR

1
1
1
1
1
1
1
1

1
1
1
1
1
1
1
1
OTM

horn

AE
ft2
102.256
102.256
120.098
120.098
120.098
158.438
158.438
158.438
275.726
kip-ft

klf

Ctrl.
Face

0.983

0.028

1.114

0.028

3.909

Tower Forces - Service - Wind 90 To Face


Section
Elevation

Add
Weight

Self
Weight

ft
L1 148.000111.000

K
0.480

K
2.258

L2 111.00074.750

0.914

3.516

L3 74.75039.500

0.914

5.303

L4 39.5000.000

1.024

8.429

Sum Weight:

3.331

19.507

F
a
c
e
A
B
C
A
B
C
A
B
C
A
B
C

CF

1
1
1
1
1
1
1
1
1
1
1
1

0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65
0.65

RR

DF

1
1
1
1
1
1
1
1
1
1
1
1

DR

1
1
1
1
1
1
1
1
1
1
1
1

1
1
1
1
1
1
1
1
1
1
1
1
OTM

AE
ft2
81.914
81.914
81.914
102.256
102.256
102.256
120.098
120.098
120.098
158.438
158.438
158.438
275.726
kip-ft

Ctrl.
Face

0.849

klf
0.023

0.963

0.027

0.983

0.028

1.114

0.028

3.909

Force Totals
Load
Case

Vertical
Forces
K

Total Member Self-Weight


Wind 0 deg - No Ice
Wind 90 deg - No Ice
Wind 180 deg - No Ice
Member Ice
Wind 0 deg - Ice
Wind 90 deg - Ice
Wind 180 deg - Ice
Wind 0 deg - Service
Wind 90 deg - Service
Wind 180 deg - Service

19.507
31.788
31.788
31.788
3.373
37.800
37.800
37.800
31.788
31.788
31.788

Sum of
Forces
X
K

Sum of
Forces
Z
K

0.000
27.488
0.000

-27.488
0.000
27.488

0.000
22.723
0.000
0.000
9.511
0.000

-22.723
0.000
22.723
-9.511
0.000
9.511

Sum of
Overturning
Moments, Mx
kip-ft
0.000
-2895.313
0.000
2895.313
0.000
-2427.437
0.000
2427.437
-1001.839
0.000
1001.839

Sum of
Sum of Torques
Overturning
Moments, Mz
kip-ft
kip-ft
0.000
0.000
0.000
-2895.313
0.000
0.000
0.000
0.000
0.000
0.000
-2427.437
0.000
0.000
0.000
0.000
0.000
-1001.839
0.000
0.000
0.000

Page

Job

ERITower

10 of 13

Example #2
Project

Computerized Structural

Date

Summit Pole

8989 N. Port Washington Road


Milwaukee, WI 53217
Phone: (414) 351-5588
FAX: (414) 351-4617

16:40:05 07/15/03

Client

Designed by

CSD

horn

Load Combinations
Comb.
No.
1
2
3
4
5
6
7
8
9
10
11

Description
Dead Only
Dead+Wind 0 deg - No Ice
Dead+Wind 90 deg - No Ice
Dead+Wind 180 deg - No Ice
Dead+Ice
Dead+Wind 0 deg+Ice
Dead+Wind 90 deg+Ice
Dead+Wind 180 deg+Ice
Dead+Wind 0 deg - Service
Dead+Wind 90 deg - Service
Dead+Wind 180 deg - Service

Maximum Member Forces


Section
No.

Elevation
ft

Component
Type

Condition

L1

148 - 111

Pole

L2

111 - 74.75

Pole

L3

74.75 - 39.5

Pole

L4

39.5 - 0

Pole

Max Tension
Max. Compression
Max. Mx
Max. My
Max. Vy
Max. Vx
Max Tension
Max. Compression
Max. Mx
Max. My
Max. Vy
Max. Vx
Max Tension
Max. Compression
Max. Mx
Max. My
Max. Vy
Max. Vx
Max Tension
Max. Compression
Max. Mx
Max. My
Max. Vy
Max. Vx

Gov.
Load
Comb.
1
5
3
2
3
2
1
5
3
2
3
2
1
5
3
2
3
2
1
5
3
2
3
2

Force
K
0.000
-11.662
-7.647
-7.647
15.375
-15.375
0.000
-19.412
-14.072
-14.072
22.047
-22.047
0.000
-26.110
-20.535
-20.535
24.564
-24.564
0.000
-37.800
-31.766
-31.766
27.514
-27.514

Major Axis
Moment
kip-ft
0.000
0.000
-322.622
0.000
-322.622
0.000
0.000
0.000
-1022.554
0.000
-1022.554
0.000
0.000
0.000
-1827.826
0.000
-1827.826
0.000
0.000
0.000
-3000.597
0.000
-3000.597
0.000

Maximum Reactions
Location

Condition

Pole

Max. Vert
Max. Hx
Max. Hz
Max. Mx
Max. Mz

Gov.
Load
Comb.
6
11
2
2
3

Vertical
K

Horizontal, X
K

Horizontal, Z
K

37.800
31.788
31.788
3000.597
3000.597

0.000
0.000
0.000
0.000
-27.488

22.723
-9.511
27.488
27.488
0.000

Minor Axis
Moment
kip-ft
0.000
0.000
0.000
322.622
0.000
322.622
0.000
0.000
0.000
1022.554
0.000
1022.554
0.000
0.000
0.000
1827.826
0.000
1827.826
0.000
0.000
0.000
3000.597
0.000
3000.597

11 of 13

Example #2
Project

Computerized Structural

Date

Summit Pole

8989 N. Port Washington Road


Milwaukee, WI 53217
Phone: (414) 351-5588
FAX: (414) 351-4617

Location

Page

Job

ERITower

16:40:05 07/15/03

Client

Designed by

CSD

Condition

Gov.
Load
Comb.
1
1
3
4
4
1
1

Max. Torsion
Min. Vert
Min. Hx
Min. Hz
Min. Mx
Min. Mz
Min. Torsion

horn

Vertical
K

Horizontal, X
K

Horizontal, Z
K

0.000
31.788
31.788
31.788
-3000.597
0.000
0.000

0.000
0.000
-27.488
0.000
0.000
0.000
0.000

0.000
0.000
0.000
-27.488
-27.488
0.000
0.000

Tower Mast Reaction Summary


Load
Combination

Vertical

Shearx

Shearz

Dead Only
Dead+Wind 0 deg - No Ice
Dead+Wind 90 deg - No Ice
Dead+Wind 180 deg - No Ice
Dead+Ice
Dead+Wind 0 deg+Ice
Dead+Wind 90 deg+Ice
Dead+Wind 180 deg+Ice
Dead+Wind 0 deg - Service
Dead+Wind 90 deg - Service
Dead+Wind 180 deg - Service

31.788
31.788
31.788
31.788
37.800
37.800
37.800
37.800
31.788
31.788
31.788

0.000
0.000
27.488
0.000
0.000
0.000
22.723
0.000
0.000
9.511
0.000

0.000
-27.488
0.000
27.488
0.000
-22.723
0.000
22.723
-9.511
0.000
9.511

Overturning
Moment, Mx
kip-ft
0.000
-3000.597
0.000
3000.597
0.000
-2541.816
0.000
2541.816
-1040.041
0.000
1040.041

Overturning
Moment, Mz
kip-ft
0.000
0.000
-3000.597
0.000
0.000
0.000
-2541.816
0.000
0.000
-1040.041
0.000

Torque
kip-ft
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000

Solution Summary
Load
Comb.
1
2
3
4
5
6
7
8
9
10
11

PX
K
0.000
0.000
27.488
0.000
0.000
0.000
22.723
0.000
0.000
9.511
0.000

Sum of Applied Forces


PY
K
-31.788
-31.788
-31.788
-31.788
-37.800
-37.800
-37.800
-37.800
-31.788
-31.788
-31.788

PZ
K
0.000
-27.488
0.000
27.488
0.000
-22.723
0.000
22.723
-9.511
0.000
9.511

PX
K
0.000
0.000
-27.488
0.000
0.000
0.000
-22.723
0.000
0.000
-9.511
0.000

Sum of Reactions
PY
K
31.788
31.788
31.788
31.788
37.800
37.800
37.800
37.800
31.788
31.788
31.788

Non-Linear Convergence Results


Load
Combination.
1
2
3
4
5
6

Converged?
Yes
Yes
Yes
Yes
Yes
Yes

Number
of Cycles
4
4
4
4
4
4

Displacement
Tolerance
0.00000001
0.00000001
0.00000001
0.00000001
0.00000001
0.00000001

Force
Tolerance
0.00000001
0.00030937
0.00030937
0.00030937
0.00000001
0.00064930

PZ
K
0.000
27.488
0.000
-27.488
0.000
22.723
0.000
-22.723
9.511
0.000
-9.511

% Error
0.000%
0.000%
0.000%
0.000%
0.000%
0.000%
0.000%
0.000%
0.000%
0.000%
0.000%

12 of 13

Example #2
Project

Computerized Structural

Date

Summit Pole

8989 N. Port Washington Road


Milwaukee, WI 53217
Phone: (414) 351-5588
FAX: (414) 351-4617

7
8
9
10
11

Page

Job

ERITower

16:40:05 07/15/03

Client

Designed by

CSD

Yes
Yes
Yes
Yes
Yes

4
4
4
4
4

0.00000001
0.00000001
0.00000001
0.00000001
0.00000001

horn

0.00064930
0.00064930
0.00011362
0.00011362
0.00011362

Maximum Tower Deflections - Service Wind


Section
No.
L1
L2
L3
L4

Elevation
ft
148 - 111
114.75 - 74.75
79.5 - 39.5
45 - 0

Horz.
Deflection
in
38.358
23.318
10.813
3.377

Gov.
Load
Comb.
9
9
9
10

Tilt

Twist

deg
2.254
1.984
1.328
0.692

deg
0.000
0.000
0.000
0.000

Critical Deflections and Radius of Curvature - Service Wind


Elevation

Appurtenance

ft
152.000
150.000
137.000
122.000
107.000

Lighthing Rod 5/8x4'


(12) DB874H
(12) DB874H
(12) DB874H
(12) DB874H

Gov.
Load
Comb.
9
9
9
9
9

Deflection

Tilt

Twist

in
38.358
38.358
33.207
26.417
20.188

deg
2.254
2.254
2.189
2.068
1.871

deg
0.000
0.000
0.000
0.000
0.000

Radius of
Curvature
ft
24812
24812
11278
4770
3523

Maximum Tower Deflections - Design Wind


Section
No.
L1
L2
L3
L4

Elevation
ft
148 - 111
114.75 - 74.75
79.5 - 39.5
45 - 0

Horz.
Deflection
in
110.407
67.162
31.169
9.739

Gov.
Load
Comb.
3
2
2
2

Tilt

Twist

deg
6.491
5.717
3.828
1.995

deg
0.000
0.000
0.000
0.000

Critical Deflections and Radius of Curvature - Design Wind


Elevation

Appurtenance

ft
152.000
150.000
137.000
122.000
107.000

Lighthing Rod 5/8x4'


(12) DB874H
(12) DB874H
(12) DB874H
(12) DB874H

Compression Checks

Gov.
Load
Comb.
3
3
3
2
2

Deflection

Tilt

Twist

in
110.407
110.407
95.600
76.075
58.157

deg
6.491
6.491
6.309
5.962
5.382

deg
0.000
0.000
0.000
0.000
0.000

Radius of
Curvature
ft
8813
8813
4004
1691
1244

Page

Job

ERITower

13 of 13

Example #2
Project

Computerized Structural

Date

Summit Pole

8989 N. Port Washington Road


Milwaukee, WI 53217
Phone: (414) 351-5588
FAX: (414) 351-4617

16:40:05 07/15/03

Client

Designed by

CSD

horn

Pole Design Data:


Section
No.
L1
L2
L3
L4

Elevation
ft
148 - 111 (1)
111 - 74.75 (2)
74.75 - 39.5 (3)
39.5 - 0 (4)

Size

Lu

Kl/r

Fa

TP29.586x22x0.219
TP36.58x28.38x0.25
TP43.307x35.106x0.313
TP50.78x41.554x0.375

ft
37.000
40.000
40.000
45.000

Actual
Mx
kip-ft
322.622
1022.55
0
1827.82
5
3000.60
0

Actual
P
K
-7.647
-14.072
-20.535
-31.766

Allow.
Pa
K
774.393
1094.150
1619.540
2339.790

ft
0.000
0.000
0.000
0.000

0.0
0.0
0.0
0.0

ksi
39.000
39.000
39.000
39.000

in2
19.856
28.055
41.527
59.995

Actual
fbx
ksi
-27.623
-50.093

Allow.
Fbx
ksi
39.000
39.000

Ratio
fbx
Fbx
0.708
1.284

Actual
My
kip-ft
0.000
0.000

Actual
fby
ksi
0.000
0.000

Allow.
Fby
ksi
39.000
39.000

Ratio
fby
Fby
0.000
0.000

-51.106

39.000

1.310

0.000

0.000

39.000

0.000

-48.233

39.000

1.237

0.000

0.000

39.000

0.000

Pole Bending Design Data:


Section
No.

Elevation

Size

L1
L2

ft
148 - 111 (1)
111 - 74.75 (2)

TP29.586x22x0.219
TP36.58x28.38x0.25

L3

74.75 - 39.5 (3)

TP43.307x35.106x0.313

L4

39.5 - 0 (4)

TP50.78x41.554x0.375

Pole Interaction Design Data:


Section
No.

Elevation

Size

L1

ft
148 - 111 (1)

TP29.586x22x0.219

Ratio
P
Pa
0.010

Ratio
fbx
Fbx
0.708

Ratio
fby
Fby
0.000

L2

111 - 74.75 (2)

TP36.58x28.38x0.25

0.013

1.284

0.000

L3

74.75 - 39.5 (3)

TP43.307x35.106x0.313

0.013

1.310

0.000

L4

39.5 - 0 (4)

TP50.78x41.554x0.375

0.014

1.237

0.000

Comb.
Stress
Ratio
0.718
1.297
1.323
1.250

Allow.
Stress
Ratio
1.333
1.333
1.333
1.333

Criteria

H1-3
H1-3
H1-3
H1-3

Section Capacity Table


Section
No.
L1
L2
L3
L4

Elevation
ft

Component
Type

Size

Critical
Element

P
K

SF*Pallow
K

%
Capacity

Pass
Fail

148 - 111
111 - 74.75
74.75 - 39.5
39.5 - 0

Pole
Pole
Pole
Pole

TP29.586x22x0.219
TP36.58x28.38x0.25
TP43.307x35.106x0.313
TP50.78x41.554x0.375

1
2
3
4

-7.647
-14.072
-20.535
-31.766

1032.266
1458.502
2158.847
3118.940

53.9
97.3
99.3
93.8
Summary
Pole (L3)
99.3
RATING =
99.3

Pass
Pass
Pass
Pass
Pass
Pass

Ratio
P
Pa
0.010
0.013
0.013
0.014

You might also like