You are on page 1of 2

WARNINGS:

1. With Vista or later, you must have Admin privileges. Right-click on CMD.EXE a
nd select Run As Administrator. You cannot run this from the RUN command as this
will not have Admin rights.
2. During the silent installation, the computer may reboot without warning up to
TWO times. Make sure all other programs are closed before before beginning the
installation. After the computer reboots, log on with the same account. The inst
allation should resume automatically. If it does not, type the same command lin
e at the DOS prompt that was run the first time.
3. If a version of the service tool prior to 2008C is currently installed on the
PC, the service tool must be uninstalled first before running the new service t
ool install silently. The old service tool can be uninstalled through "Add or R
emove Programs" or "Programs and Features" under "Control Panel". If a procedur
e was provided with the old service tool to uninstall it silently, this may be u
sed as well.
----'setup' in the commands below means the fully qualified path to setup.exe. For e
xample, "D:\setup.exe" /S /v/qn
----To install this service tool silently (no user interface shown), use the followi
ng command line:
setup /S /v/qn
Warning: If a reboot of the PC is required by the install, this will happen auto
matically.
If a log file of the install is desired, use the following command line instead:
setup /S /v"/qn /l*v %temp%\STPLInstall.log"
The log file will be created in your temp directory.
----To install this service tool as an unattended install (user interface shown, but
no user interaction required), use the following command line:
setup /L1033 /v/qb
The user will be prompted by the install if a PC reboot is required. The user i
nterface will be shown in English. To show the user interface in another langua
ge other than English, replace '1033' with one of the following values:
French = 1036
German = 1031
Italian = 1040
Spanish = 1034
Portuguese = 2070
Japanese = 1041
Chinese (Simplified) = 2052
Danish = 1030

If a log file of the install is desired, use the following command line instead:
setup /L1033 /v"/qb /l*v %temp%\STPLInstall.log"
The log file will be created in your temp directory.
----The 'setup' executable will have a return code of '0' if the install was success
ful. The return code will be '3010' if the install was successful, but a reboot
is required. Any other return code indicates that the install failed.
----To uninstall this service tool silently (no user interface shown), use the follo
wing command line:
setup /S /x /v/qn

You might also like