You are on page 1of 4
SiJayePaig INI Wnnse, Sdalias-yA MAN TAAACO OS ae eg VK-series Vacuum Circuit Breakers Building on lwo decades of experience manufacturing Vacuum Circuit Breakers, Tamco has expanded its 12kV VCB range to include a new VKseries, designed to meet the needs of Original Equipment Manufacturers. Designed and tested to IEC 60056: Up to 12kV rated voltage 630, 1250, 2000 normal current 20, 25 or 31.5kA 3 second short-circuit current 75 or 95KV impulse withstand voltoge Shorteircuit proven ot KEMA The new VK:series circuit breakers are available in 3 configurations: * Cassette suitable for metalclad switchgear; * Cassette suitable for metal-enclosed switchgear; or * Vocuum Circuit Breaker only Key Features * Horizontal isolation, horizontal drawou * Isolation mechanism operable with door closed * Suitable for mid-panel mounting or mulitier cubicles * Comprehensive safely interlocks * Minimal maintenance For metalelad swilchgeor- cassette filed with cast resin bushings lo segregaie VCB comporiment; metalic shutters individually padlockable. For metalenclosed switchgear. cassette fitted with insulated partition plate and insulated shutters For VCB only- moving-portion supplied with floor tray for easy clignment and interlocks. Safety interlacks * VCB cannot be engaged or withdrawn unless it is in the open position + VCB can only be closed or opened if itis in the engaged or isolated positions (and not in-between) * Provision for interlocking with earthing switch * Provision for interlocking with cubicle door * Optional key interlocks to meet specific operational requirements For Metalclad Switchgear ajziae For Metal-E Vacuum Circuit Breaker Model v«- | 10520 |10M20] 10525 |10M25] 10P25 |10M32| 10P32 Voltage (kV) 12 Insulation level: Impulse withstand (kVp) 75,95 7” I-min Power Freq (kV) 28 , 38, 42 > | Frequency (Hz) 50 =a [Normal Current (A] 630 [| 1250 | 630 | 1250 | 2000 | 1250 | 2000 mm | ‘Short-Circuit Breaking Current (kA) 20 25 31.5 © | Transient Recover Voltage (kVp) 20.6 ‘ShortCircuit Making Current (kAp) 50 63 80. Operating sequence 0-0.3 sec-CO-3 min-CO Duration of Short-circuit (S) 3 Opening Time (mS) 35 Break Time <3 Cycles Closing Time at No Load (mS) 50 Closing Voltage (V DC) 30,110 Current (A) 6.53.5 Tripping Voltage (V DC) 30,110 Current (A) 6.5 ,3.5 Full Load switching Life (no. of Operations) 10,000 Auxiliary Contacts 3a + 3b Approx. Weight: (Metalclad) kg 130 | 135 | 135. | 145 | 165 | 170 | 180 Approx. Weight: (Metal-Enclosed) kg 90 | 95 | 95 | 105 | 125 | 130 | 140 Approx. Weight: (VCB ony) kg 7o | 75 | 75 | 80 | 95 | 105 | 110 Manufactured using state-of-the-art laser and robotic technology Independently tested at KEMA. gat eel orga pe, bone pr en ets henge ws Srey ded apse avn og joing proce TA ” _ TAMCO SWITCHGEAR (MALAYSIA) SDN BHD 0 V ico ‘SUBLOT 24, LOT 16505. JALAN KELULI 1, PO. BOX 2 KAWWASAN PERINDUSTRIAN BUKIT RAJA, SEKSYEN 7, 40002 SHAH ALAM, ‘SELANGOR DARUL EH-AN, MALAYSIA, TEL +609:396' 8260 FAX, +0093041 6200 Email terco tamea.com my Webs: wnwtamca.com.my

You might also like