You are on page 1of 103

TABLE OF CONTENTS

Item
Page
ANSI/AWWA Compact & Full Body Pipe Fittings:
Mechanical & Flange Joint C153.3-9
Mechanical & Plain End C153..3-5,8
Mechanical & Swivel Joint C153.3,4,6
Mechanical Joint Offsets, Wyes, Reducers C153.4,8
Mechanical Joint Sleeves, Caps, Plugs C1539,10
Mechanical Joint Tapped Tees C153...9
Swivel by Swivel Hydrant Joint C153..5,7
Plain End by Plain End Joint C153..8
Mechanical & Flange Joint C110 Full Body......13-22
Mechanical & Plain End Joint C110.13-15,19
Mechanical & Swivel Joint C110.....22
Mechanical Joint Sleeves, Caps, Plugs C110.20,21
Mechanical Joint Offsets, Wyes, Crosses C110..18,21
Mechanical Joint Tapped Tees C110.16
Mechanical by FIPT Joint, Reducers C110..14,19
Plain End by Plain End Joint C11019
Swivel by Swivel Hydrant Joint C110....23
Flange by Flange Joint C110.30-33
Flange by Flare Joint, Reducers, Wyes C110....33-35
Flange by Flange Joint w/Base C110..35,36
Flanged Sludge Shoe C110.36
Flanges Threaded and Blind C110...36
Push on & Flange Joint Compact...24,25,27-29
Push on & Plain End Joint Compact.26
Push on & Swivel Joint Compact...27
Push on Joint Adapters, Caps, Plugs, Compact21,28
Push on Tap Tees, Crosses, Wyes, Reducers Compact..28,29
Adapters Mechanical, Flange, Plain End Joint C153..9
Adapters Mechanical & Flange Joint C110.20
Adapter Flanges w/Setscrews..37,48
Tapping Sleeve C153...12,22,64

Item
Page
Product Submittals and Installation:
20U Protective Fusion Bonded Epoxy....56,57
21U Cement, Mortar, Asphaltic Materials..58
22U Domestic ANSI/AWWA C110 Fittings..59
22U Non-Domestic ANSI/AWWA C110 Fittings..60
23U Domestic ANSI/AWWA C153 Fittings..61
23U Non-Domestic ANSI/AWWA C153 Fittings..62
24U Mechanical Joint Retainer Gland...63
25U Pipe Tapping Sleeves..64
26U - Domestic Push on Tyton Joint Fittings....65
26U Non-Domestic Push on Tyton Joint Fittings...66
27U ANSI/AWWA C111 Fasteners...53
28U Domestic ANSI/AWWA C110 Flange Fittings....67
28U Non-Domestic ANSI/AWWA C110 Flange Fittings.68
29U Domestic ASTM A48 Valve Boxes..69
30U Non-Domestic ASTM A48 Valve Boxes..70
31U Mechanical and Push on Joint Gaskets29,71,72

Fitting & Pipe Specifications & Dimensions:


ANSI/AWWA C153/A21.53 MJ Compact..3,61,62
ANSI/AWWA C110/A21.10 MJ Full Body..13,59,60
ANSI/AWWA C110/A21.10 Flange Full Body..30,31,67,68
Union-Tite Push On Compact.24,65,66
Pipe Diameter Chart (Reference Only)..50
ANSI/AWWA C153 Compact Flange Detail..61,62
ANSI/AWWA C110 Full Body Flange Detail..30,31,67,68

Municipal Castings & Valve and Service Boxes:


Service or Curb Box Screw Type.38
Valve or Road Two-Piece Box Screw Type..39,43
Valve or Road Two-Piece Slip Type..41
Extensions38,40,42,44
Lids (Drop, Repair, MMW, Locking, Special)..38,45,47
Bases (Service, Valve)......38,44
Risers (Fixed, Adjustable)...46
Meter Box, Ring and Cover...47
Wrenches38,45,47

Frequently Asked Questions:


Tap Locations for Flanged Fittings..37
Product Certification...98
Terms and Conditions of Sale....99-102
Making Offsets on the Job49
About Tyler Union Products......51,52
Installation Cutting-In and DUO Sleeve.....10,20

Pipe Restraint Submittals and Installation:


Series 1000 Domestic TLD MJ TUF Grip for DI..73-75
Series 1000 Non-Domestic TLD MJ TUF Grip DI..76-78
Series 1000S Split TLD TUF Grip for DI...79-81
Series 2000 Domestic TLP MJ TUF Grip for PVC/PVCO..82-84
Series 2000 Non-Domestic TLP MJ TUF Grip PVC/PVCO..85-87
Series 2000S Split TLP TUF Grip for PVC.....88-90
Series 3000PP (Pipe to Pipe PVC).....91,92
Series 3000PS (PVC Pipe Stop)93
Series 3000MJ (MJ Fitting to PVC Pipe)...94,95
Series 100 (MJ Retainer Gland to DI Pipe)..10,22,63
Sure Stop 350 Push On Tyton Joint Restraint Gasket.96,97
MJ Field LOK for DI..54,55
MJ Field LOK for PVC..54,55

Accessories:

Glands C153 (Dual Purpose, Solid, Split).7,10,11


Glands C110 (Solid, DUO, Swivel)..20,22,23
Gaskets MJ, Tyton, Transition, DUO.20,29,71,72

NOTICE: 1) Weights published in this catalog are guideline for shipping purposes only. Actual weights may vary as some fittings
are manufactured in multiple locations. All fittings meet the ANSI/AWWA standards. For weights of specific fittings,
contact Tyler Union Waterworks.
2) For the flange thickness or laying lengths of specific fittings, please contact Tyler Union Waterworks
2

MECHANICAL JOINT C153 DUCTILE IRON


COMPACT FITTINGS

Sizes 3"-12" UL & 3"-10" FM Listed


For Fire Main Equipment

SAMPLE SPECIFICATIONS (Current ANSI/AWWA revisions apply)


Mechanical joint watermain fittings with accessories, " through *64" shall be manufactured from uctile ron in
accordance with and meet all applicable terms and provisions of standards ANSI/AWWA C153/A21.53
ANSI/AWWA C111/A21.11 Ductile ron echanical oint ittings 2" through 24" shall be rated
working pressure. 30" through 48" shall be rated for 250 psi working pressure. Flanged ductile iron
fittings in 24" (610 mm) and smaller sizes may be rated for 350 psi (2,413 kPa) with the use of special (annular
ring or comparable) gaskets. All coated
fittings meet requirements of NSF-61, NSF-372, and Annex G.
NOTE - EXCEPTIONS: Mechanical joint ittings with flanged branches are rated for water pressure of 250 PSI.
NOTE - Wyes over 12" are not pressure rated. Contact manufacturer for rating in your application.
NOTE - Fittings are cement
and seal coated in accordance with ANSI/AWWA C104/A21.4. Fittings are
available double cement-lined, bare, or epoxy coated upon request. Epoxy coating per ANSI/AWWA C116
NOTE - Installation per AWWA C600 and AWWA C651

NOMINAL JOINT DIMENSIONS IN INCHES

Size A Dia.

BOLTS

C Dia.

D Dia.

F Dia.

J Dia.

K1 Dia.

K2 Dia.

Size

No.

2.51

2.50

3.50

3.60

2.61

4.75

6.19

6.89

.58

.62

.36

.30

x3

3.96

2.50

4.84

4.94

4.06

6.19

7.62

7.69

.58

.62

.39

.33

.x3

4.80

2.50

5.92

6.02

4.90

7.50

9.06

9.12

.60

.75

.39

.34

x3

6.90

2.50

8.02

8.12

7.00

9.50

11.06

11.12

.63

.88

.43

.36

x3

9.05

2.50

10.17

10.27

9.15

11.75

13.31

13.37

.66

1.00

.45

.38

x4

10 11.10

2.50

12.22

12.34

11.20

14.00

15.62

15.62

.70

1.00

.47

.40

x4

12 13.20

2.50

14.32

14.44

13.30

16.25

17.88

17.88

.73

1.00

.49

.42

x4

14 15.30

3.50

16.40

16.54

15.44

18.75

20.31

20.25

.79

1.25

.55

.47

x4

10

16 17.40

3.50

18.50

18.64

17.54

21.00

22.56

22.50

.85

1.31

.58

.50

x4

12

18 19.50

3.50

20.60

20.74

19.64

23.25

24.83

24.75

1.00

1.38

.68

.54

x4

12

20 21.60

3.50

22.70

22.84

21.74

25.50

27.08

27.00

1.02

1.44

.69

.57

x4

14

24 25.80

3.50

26.90

27.04

25.94

30.00

31.58

31.50

1.02

1.56

.75

.61

x5

16

30 32.00

4.00

33.29

33.46

32.17

36.88

39.12

39.12

1.31

2.00

.82

.66

1x6

20

36 38.30

4.00

39.59

39.76

38.47

43.75

46.00

46.00

1.45

2.00

1.00

.74

1x6

24

42 44.50
48 50.80

4.00
4.00

45.79
52.09

45.96
52.26

44.67
50.97

50.62
57.50

53.12
60.00

53.12
60.00

1.45
1.45

2.00
2.00

1.35
1.35

.82
.90

1
1.

1x6
1x6

28
32

NOTE: 2 Inch MJ ASTM A536 ductile iron Compact fittings (2"-22.5 bend, 2"-45 bend, 2"-90 bend, 2"x12" solid sleeve, 2"x2" tee, 4"x2"
tee, and 4"x2" reducer) are available beginning 2012. Call Tyler Union for availability or additional product dimensions.
*NOTE: Contact Tyler Union for 54"-64" product information.

NOTE: The fitting laying lengths provided are approximate, contact Tyler Union Waterworks for the
laying length of a specific fitting.

256772_utility catalog.pdf 3

12/15/08 8:24:18 AM

MECHANICAL JOINT C153 DUCTILE IRON


COMPACT FITTINGS
Sizes 3"
UL
For Fire Main Equipment

Listed

BENDS

90Bends (1/4)


Size

Dimensions
T
*A

45 Bends (1/8)


Weight

imensions
D
*A
R


Weight

imensions
D
*A
R

2.51

imensions
D
*A
R

15

Weight

.34

3.5

2.5

19

2.00

2.41

.35

4.0

3.0

22

2.50

3.56

20

1.75

3.81

.37

6.5

6.0

49

3.50

7.25

39

2.25

6.35

.39

7.5

7.0

64

4.00

8.44

56

2.85 11.80

50

2.06 15.80

45

10

.41

9.5

9.0

102

5.01 10.88

78

3.35 14.35

66

2.32 18.36

59

12

.43 10.5

10.0

129

5.98 13.25

102

3.86 16.90

87

2.56 20.90

82

14

.51 12.0

11.5

214

5.50 12.06

155

3.93 17.25

142

2.59 21.25 136

16

.52 13.0

12.5

273

5.98 13.25

204

3.98 17.50

178

2.62 21.50 157

18

.59 15.5

14.0

411

6.50 12.36

292

7.50 30.19

286

3.00 60.84 283

20

.60 17.0

15.5

519

7.00 13.59

372

8.50 35.19

376

3.50 71.07 374

24

.62 17.0

15.5

721

7.50 14.89

490

9.00 37.69

512

3.50 76.12 487

30 .66 21.50 19.0

930

9.31

1.50

11 Bends (1/32)


Weight

10.50

17

22 Bends (1/16)

1.25

2.53

16

18

1.50

5.12

18

31

1.50

5.12

29

716

6.75 21.36

665

4.75 22.84 600

36

.74 24.50 22.0 1450

11.50 21.73 1110

7.75 26.39

960

5.00 25.38 820

42

.82 29.25 26.7 2205

14.00 27.76 1610

9.00 32.68 1350

6.00 35.54 1180

48
.90 33.25 30.75 2990
15.00 30.17 2090
10.00 27.70 1760
6.50 40.61 1475
*NOTE: "A" dimensions are approximate, contact Tyler Union for the laying length of a specific fitting
**Note: 2 Inch Compact ductile iron 22.5, 45, and 90 degeree bends available in 2012. Call Tyler Union for information.

OFFSETS

MJ x MJ

BENDS
MJ x PE



Size

Dimensions
L 1
L

4
4
4
4
6
6
6
6
8
8
8
10
12

6
12
18
24
6
12
18
24
6
12
18
12
6

10
18
22
28
12
18
24
30
13
19
25
21
17

--
---
--
17.5
--
--
---
---
---

5-5/8 Bends (1/64) MJ x MJ

Weights
MJxMJ MJxPE

42
52
58
70
50
65
82
91
79
96
116
136
137

--------------

Size

3
4
6
8
10
12
14
16
18
20
24
30
36
42
48

Dimensions
*A
R

1.25
1.50
1.50
1.75
2.00
2.30
2.50
2.50
3.00
3.00
3.00
3.75
4.00
5.00
5.50

Weight

5.08
16
7.61
18
10.15
29
12.69
45
15.23
59
17.77
82
20.31 136
20.31
157
25.38
283
25.38
374
25.38
487
32.97
600
34.55
820
42.71 1180
47.35 1475
4

MECHANICAL JOINT C153 DUCTILE IRON


COMPACT FITTINGS

Sizes 3"-12" UL & 3"-10" FM Listed


For Fire Main Equipment

BENDS

90Bend MJ x PE (1/4)


Size

Dimensions
*A Y

3
4
6
8
10
12
14
16
20
24
30

.34
.35
.37
.39
.41
.43
.51
.52
.57
.62
.68

90Bend MJ x Flange
(1/4)


Size

3
4
6
8
10
12
14
16

3.5
4.0
6.0
7.5
9.5
9.0
12.0
13.0
15.0
17.0
21.5

9.0
9.5
11.5
13.0
15.0
14.4
20.0
21.0
23.0
25.0
30.5

2.5
3.0
5.0
7.0
9.0
6.0
11.5
12.5
13.5
15.5
--

Dimensions
*A R

.34 3.5
2.5 5.5
.35 4.0
3.0 6.5
.37 6.0
5.0 8.0
.39 7.5
7.0 9.0
.41 9.5
9.0 11.0
.43 10.5 10.0 12.0
.51 12.0 11.5 14.0
.52 13.0 12.5 15.0

45Bend MJ x PE (1/8)

Weight

Dimensions
*A
Y
R

18 2.0
26 2.5
45 3.2
64 4.0
108 5.0
114 6.0
219 5.5
254 6.0
400 7.0
710
7.5
865 10.5

7.5
8.0
8.7
9.5
10.5
11.5
13.4
14.0
15.3
16.6
19.5

2.41
3.56
5.49
8.44
10.88
13.25
10.85
13.25
13.97
14.69
--


Weight

17
22
38
55
78
104
165
206
290
460
715

45Bend MJ x Flange
(1/8)

Weight

21
28
45
73
113
141
217
280

Dimensions
*A
R
F

...
...
2.50 3.56
3.25 5.49
4.25 7.93
5.00 9.76
6.00 12.19
5.50 10.85
6.00 12.02

..
4.0
5.0
5.5
6.5
7.5
8.5
9.5


Weight

..
34
57
83
122
159
207
290

22 Bend MJ x PE (1/16) 11 Bend MJ x PE (1/32)


Dimensions
*A
Y
R

1.50 7.00
1.75 7.25
2.25 7.75
2.84 8.34
3.35 8.85
3.50 9.00
3.93 11.93
3.98 11.98
--9.00 17.66
6.75 15.75


Weight

2.51
3.81
6.35
11.80
14.35
12.70
17.25
17.50
-37.69
--

19
20
33
51
66
89
152
181
-455
600

22 Bend MJ x Flange
(1/16)
Dimensions
*A
R
F

...
1.75
2.25
2.50
3.00
3.50

...
3.81
5.35
7.62
10.16
12.70


Weight

..
..
4.0
34
5.0
57
5.5
83
6.5 122
7.5 159

Dimensions
*A
Y
R

1.25 6.75
1.50 7.00
1.50 7.00
2.05 7.55
2.31 7.81
2.56 8.06
2.59 10.59
2.62 10.62
--9.00 26.12
---

Weight

7.62
5.12
5.12
15.80
18.36
20.90
21.25
21.50
-12.00
--

15
20
32
44
60
79
137
161
-475
--

11 Bend MJ x Flange
(1/32)
Dimensions
*A
R
F

...
1.50
1.50
1.75
2.00
2.25

...
5.12
5.12
7.70
10.25
12.82

..
4.0
5.0
5.5
6.5
7.5

Weight

..
19
30
50
75
88

90Swivel x Swivel Hydrant Ell




Size T
**Weight

.37 10.5 15.5

Dimensions
C
D

6.90 11.2

6.81

7.98

6.0

74

** Weight includes two swivel glands.


*NOTE: "A" dimensions are approximate, contact Tyler Union for the laying length of a specific fitting

256772_utility catalog.pdf 5

12/15/08 8:24:18 AM

MECHANICAL JOINT C153 DUCTILE IRON


COMPACT FITTINGS
Sizes 3"-12" UL & 3"-10" FM Listed
For Fire Main Equipment

CROSS

TEES

MJ Tee

Size

MJ x FE Tee

T1


*H

Dimensions
*J1

MJ x Swivel Tee

*J2

*J3


MJ

Cross

Weights
MJxFE
MJxS

Cross

3
.34
.34
3.5
3.50
5.5
...
26
29
...
31
4x3
.35
.34
3.5
4.00
6.5
...
35
34
...
39
4
.35
.35
4.0
4.00
6.5
...
36
39
...
45
6x3
.37
.34
4.0
4.00
6.5
...
51
54
...
...
6x4
.37
.35
4.0
5.00
8.0
...
52
57
...
62
6
.37
.37
5.0
5.00
8.0
10.50
66
68
77
79
8x3
.39
.34
4.0
6.50
9.0
...
56
...
...
...
8x4
.39
.35
4.5
6.50
9.0
...
72
82
...
84
8x6
.39
.37
5.5
6.50
9.0
11.50
79
81
105
98
8
.39
.39
6.5
6.50
9.0
11.50
90
101
116
112
10x3
.41
.34
4.0
7.50
11.0
...
80
...
...
...
10x4
.41
.35
4.5
7.50
11.0
...
82
92
...
98
10x6
.41
.37
5.5
7.50
11.0
13.00
99
116
114
121
10x8
.41
.39
6.5
7.50
11.0
13.00
116
128
138
135
10
.41
.41
7.5
7.50
11.0
...
132
144
...
156
12x3
.43
.34
4.0
8.75
12.0
...
99
...
...
...
12x4
.43
.35
4.5
8.75
12.0
...
108
118
...
119
12x6
.43
.37
5.5
8.75
12.0
14.25
119
133
132
138
12x8
.43
.39
6.5
8.75
12.0
14.25
126
146
149
149
12x10
.43
.41
7.5
8.75
12.0
...
159
174
...
187
12
.43
.43
8.75
8.75
12.0
...
171
198
...
202
14x6
.51
.44
6.5
10.50
14.0
16.00
183
205
211
210
14x8
.51
.45
7.5
10.50
14.0
...
211
...
...
231
14x10
.51
.46
8.5
10.50
14.0
...
229
244
...
255
14x12
.51
.47
9.5
10.50
14.0
...
245
284
...
269
14
.51
.51
10.5
10.50
14.0
...
281
291
...
299
16x6
.52
.45
6.5
11.50
15.0
17.00
222
230
243
250
16x8
.52
.46
7.5
11.50
15.0
...
245
248
...
264
16x10
.52
.47
8.5
11.50
15.0
...
265
287
...
286
16x12
.52
.48
9.5
11.50
15.0
...
277
312
...
312
16x14
.52
.51
10.5
11.50
15.0
...
317
348
...
...
16
.52
.52
11.5
11.50
15.0
...
337
324
...
451
18x6
.59
.44
6.5
14.50
15.5
18.00
275
261
279
...
18x8
.59
.45
7.5
14.50
14.5
...
280
351
...
...
18x10
.59
.47
8.5
12.50
...
...
286
...
...
...
18x12
.59
.49
9.5
12.50
...
...
372
...
...
...
18x14
.59
.56
10.5
12.50
...
...
415
...
...
...
18x16
.59
.57
11.5
12.50
...
...
445
...
...
...
18x18
.59
.59
13.0
12.50
...
...
490
...
...
...
NOTE: Contact TU Inside Sales representative for MJ Crosses larger than 16 inch. MJxSwl Weights include swivel gland.
**NOTE: 2"x2" and 4"x2" Compact C153 tees available in 2012. Call Tyler Union for information.
*NOTE: "H" and "J" dimensions are approximates. contact Tyler Union for the laying length of specific fittings

MECHANICAL JOINT C153 DUCTILE IRON


COMPACT FITTINGS
Sizes 3"
UL
For Fire Main Equipment

TEES (Continued)

Listed

MJ GLANDS

Glands

MJ Tee

Size

20x6
20x8
20x10
20x12
20x14
20x16
20x18
20x20
24x6
24x8
24x10
24x12
24x14
24x16
24x18
24x20
24x24
30x6
30x8
30x12
30x16
30x18
30x20
30x24
30x30
36x12
36x16
36x24
36x30
36x36
42x12
42x24
42x30
42x36
42x42
48x12
48x24

48x36
48x42
48x48
NOTE: "H"

MJ x FE Tee

T1


*H

Dimensions
*J1
*J2

MJ x Swivel Tee

*J3

.60
.44
7.0
16.0
17.0
19.5
.60
.45
8.0
14.0
...
...
.60
.47
9.0
14.0
...
...
.60
.49
10.0
14.0
...
...
.60
.56
11.0
14.0
...
...
.60
.57
12.0
14.0
...
...
.60
.59
13.0
14.0
...
...
.60
.60
14.0
14.0
...
...
.62
.44
7.0
18.0
19.0
21.5
.62
.45
8.0
16.0
...
...
.62
.47
9.0
16.0
...
...
.62
.49
10.0
18.0
...
...
.62
.56
11.0
16.0
...
...
.62
.57
12.0
19.5
...
...
.62
.59
13.0
16.0
...
...
.62
.60
15.0
17.0
...
...
.62
.62
17.0
17.0
...
...
.66
.36
7.0
20.0
...
...
.66
.38
8.5
20.0
...
...
.66
.42
10.0
20.0
...
...
.66
.50
12.5
20.0
...
...
.66
.52
14.0
20.0
...
...
.66
.57
15.0
20.0
...
...
.66
.61
16.0 20.0
...
...
.66
.66
20.0
20.0
...
...
.74
.50
10.5
23.5
...
...
.74
.50
12.5
23.5
...
...
.74
.61
16.0
23.5
...
...
.74
.66
20.0
23.5
...
...
.74
.74
23.5
23.5
...
...
.82
.62
10.0
29.5
...
...
.82
.62
20.0
30.0
...
...
.82
.66
22.0
30.0
...
...
.82
.74
30.0
30.0
...
...
.82
.82
30.0
30.0
...
...
.90
.62
23.0
32.0
...
...
.90
.62
33.5
32.0
...
...


.90
.82
33.5
33.5
...
...
.90
.82
33.5
33.5
...
...
.90
.82
33.5
33.5
...
...
and "J" are approximate, contact Tyler Union


MJ

Weights
MJxFE

MJxS

Size Weight

Size Weight

18
20
24
30
36
42
48

4
6
8
10
12
14
16

3
4
5
6
9
10
17
21

22
32
37
85
115
180
275

Swivel Glands, page 23


Retainer Glands, page

335
362
358
390
...
...
417
...
...
460
...
...
475
...
...
530
...
...
560
...
...
605
...
...
465
451
457
475
...
...
516
...
...
Swivel x Solid Adapter
549
580
...
with Swivel Gland
585
...
...

Size
by
Wall
625
744
...
Laying
Length
Thickness
Weight
675
...
...

6x13
.37
52
740
...
...

6x18
.37
65
844
...
...

6x24
.37
69
700
...
...

8x12
.39
52
739
...
...
739
...
...
959
...
...
975
...
...
995
...
...
1160
...
...
1323
...
...
1103
...
...
1350
...
...
1498
...
...
Swivel x Swivel Adapter
1555
...
...
Size by
Wall
1910
...
...
Laying Length Thickness Weight
1410
...
...
6x12
.37
28
2295
...
...
6x18
.37
49
2337
...
...
6x24
.37
52
3000
...
...
3169
...
...
MJxSwivel Tee Weights include swivel
2500
...
...
gland
2822
...
...


3982
...
...
4100
...
...
4251
...
...
for the specific laying length of a fitting
7

MECHANICAL JOINT C153 DUCTILE IRON


COMPACT FITTINGS

Sizes 3"
UL & 3"-10" FM Listed
For Fire Main Equipment

REDUCERS

WYES/LATERAL

MJ x MJ





Size

4x3
6x3
6x4



Dimensions
8x4
1
Size
A
Y
T
T
Weights
8x6
3
2.5
7.5
.34
.34
36
10x4
4x3
2.0
8.5
.35
.34
39
10x6
4
2.5
8.5
.35
.35
45
10x8
6x4
1.5
11.0
.37
.35
67
12x4
6
3.0
13.0
.37
.37
85
12x6
8x4
0.5
13.0
.39
.35
86
12x8
8x6
2.0
14.5
.39
.37 109
12x10
8
3.5
16.0
.39
.39 117
14x6
14x8
10x4
0.0
15.0
.41
.35 112
14x10
10x6
1.0
16.0
.41
.37 129
14x12
10x8
2.5
17.0
.41
.39 162
16x6
10
3.5
19.0
.41
.41 199
16x8
12x4
0.0
16.5
.43
.35 141
16x10
12x6
1.5
18.5
.43
.37 170
16x12
12x8
1.5
18.5
.43
.39 177
16x14
12x10 3.0
20.0
.43
.41 216
18x8
12
4.5
22.5
.43
.43 269
18x10
14
6.0
25.0
.51
.51 476
18x12
t16x6
0.0
21.0
.52
.45 300
18x14
t16x8
0.5
22.5
.52
.46 349
18x16
16x12 3.5
25.0
.52
.48 471
20x10
16
6.5
28.0
.52
.52 635
20x12
*Not included in AWWAC153, laying lengths are approx. 20x14
Rated at 250 psi.
20x16
20x18
MJ x FE Flange Dimensions are on inside
24x12
front cover.
24x14
24x16
24x18
24x20
30x16
30x18
30x20
*MJ x PE x MJ Tee
30x24
36x16



Dimensions
Size
T
T1
H
J1
Z Weights 36x20
36x24

6 .37 .37 5.0 5.0 11.5 57
36x30
8x6 .39 .37 5.5 6.5 11.5 79

8 .39 .39 6.5 6.5 12.5 83
42x30
10 .41 .41 7.5 7.5 13.0 133
42x36
48x30
*Note: Laying lengths are approximate, contact
Tyler Union for the laying length of a specific fitting
48x36
48x42
*Wyes

PExMJSEB



T1

.35
.37
.37
.39
.39
.41
.41
.41
.43
.43
.43
.43
.51
.51
.51
.51
.52
.52
.52
.52
.52
.59
.59
.59
.59
.59
.60
.60
.60
.60
.60
.62
.62
.62
.62
.62
.66
.66
.66
.66
.74
.74
.74
.74
.82
.82
.90
.90
.90

.34
.34
.35
.35
.37
.35
.37
.39
.35
.37
.39
.41
.44
.45
.46
.47
.45
.46
.47
.48
.51
.45
.47
.49
.56
.57
.47
.49
.56
.57
.59
.49
.56
.57
.59
.60
.50
.54
.57
.61
.50
.57
.61
.66
.74
.74
.66
.74
.82

MJLEBxPE

Dimensions
MJ
SEB
LEB
L
L
L

3.0
5.0
4.0
5.0
4.0
7.0
5.0
4.0
9.0
7.0
5.0
4.0
9.0
7.0
5.0
4.0
11.0
9.0
7.0
5.0
4.0
14.0
12.0
10.0
8.0
7.0
14.0
12.0
10.0
8.0
7.0
16.0
14.0
12.0
10.0
8.0
30.0
28.0
24.0
10.0
30.0
36.0
19.0
15.5
20.0
15.5
40.0
28.0
15.5

(laying lengths are approximate)

8.5
10.5
9.5
10.5
9.5
12.5
10.5
9.5
14.5
12.5
10.5
9.5
17.0
15.0
13.0
12.0
19.0
17.0
15.0
13.0
12.0
22.0
20.0
18.0
16.0
15.0
22.0
20.0
18.0
16.0
15.0
24.0
22.0
20.0
18.0
16.0
39.0
37.0
33.0
24.5
...
45.0
33.0
24.5
...
...
...
...
...

8.5
10.5
9.5
10.5
9.5
12.5
10.5
9.5
14.5
12.5
10.5
9.5
14.5
12.5
10.5
9.5
16.5
14.5
12.5
10.5
12.0
19.5
17.5
15.5
16.0
15.0
19.4
17.5
17.8
15.8
15.0
21.4
21.8
19.8
18.0
16.0
...
...
...
...
...
...
...
...
...
...
...
...
...

PE
L

PE x PE

MJ

14.0 18
16.0 28
15.0 28
16.0 36
15.0 39
18.0 53
16.0 59
15.0 54
20.0 67
18.0 64
16.0 57
15.0 63
22.5 104
20.5 104
18.5 100
17.5 100
24.5 132
22.5 136
20.5 128
18.5 120
20.0 140
27.5 201
25.5 196
23.5 175
24.0 180
23.0 194
27.5 225
25.5 214
26.0 208
24.0 225
23.0 233
29.5 320
30.0 314
28.0 325
26.0 325
24.0 315
... 475
... 495
... 525
... 478
... 789
... 970
... 770
... 838
... 1067
... 1116
... 1852
... 1632
... 1486

Weights
SEB LEB

17
25
26
34
38
46
48
52
61
58
62
61
107
107
102
101
131
128
124
123
139
180
180
170
181
180
210
208
198
215
220
302
325
319
310
305
565
590
560
495
890
874
746
725
...
...
...
...
...

17
27
27
36
39
51
52
52
68
66
65
65
112
108
100
100
141
136
128
119
138
195
185
190
200
190
210
210
205
222
...
300
322
340
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...

PE

18
20
26
33
30
...
49
47
60
54
60
57
...
...
...
100
128
136
123
113
133
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...

MECHANICAL JOINT C153 DUCTILE IRON


COMPACT FITTINGS
Sizes 3"
UL & 3"-10" FM Listed
For Fire Main Equipment

SOLID & TAPPED PLUGS & CAPS

SOLID SLEEVES

3"-12" 14"-24"
3"-12" 14"-24"
MJ Plug
MJ Cap


Size

Weights
Plugs

Caps


Size

9
9
18
25
36
47
76
98
138
158
223
355
688
1091
1455

3
4
6
8
10
12
14
16
18
20
24
30
36
42
48

Dimensions
T

Max.
Tap

.46
.46
.46
.46
.56
.56
.62
.62
.65
.66
.68
.66
.74
.82
.90

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

*TAPPED TEE

8
10
18
26
32
46
85
94
121
149
210
345
626
723
974
MJ x FE Flange
Dimensions are
on inside front
cover.

Short

T

Dimensions
L 1

Long

L2

Weights
Short

Long

3
.34
7.5
12
4
.35
7.5
12
6
.37
7.5
12
8
.39
7.5
12
10
.41
7.5
12
12
.43
7.5
12
14
.56
9.5
15
16
.57
9.5
15
18
.68
9.5
15
20
.69
9.5
15
24
.75
9.5
15
30
.66
15.0
15
30
.66
...
24
36
.74
15.0
15
36
.74
...
24
42
.82
...
24
48
.90
...
24
Note: 2"x12" C153 Sleeves available, call

13
22
19
25
28
39
38
55
48
68
62
81
116
146
138
174
160
230
212
269
272
380
500
...
...
640
725
662
...
925
...
1146
...
1455
for information

ADAPTERS

*Note: Verify non-domestic laying lengths with Tyler Union

MJ Tapped Tee (2" Tap)


Size

Dimensions
T

*L


Max. Tap



Weights

3
.34
6
2
19
4
.35
6
2
23
6
.37
6
2
35
8
.39
6
2
54
10
.41
6
2
68
12
.43
6
2
88
16
.52
6
2
164
Note: "L" dimensions are approximate, contact Tyler
Union for laying length of a spcific fitting

MJ x FE


Size

3
4
6
8
10
12
14
16
18
20
24
30
36

.34
.35
.37
.39
.41
.43
.51
.52
.56
.60
.62
.66
.74

Dimensions
L 1

*6
*6
*6
*6
*6
*6
*6
*6
*6
*6
*6
*7
*8

FE x PE

L2

12
12
12
12
12
12
12
12
...
...
...
...
...

Weights
MJxFE

FExPE

18
26
36
50
60
88
127
155
195
275
305
470
750

...
23
35
50
69
88
...
149
...
...
...
...
...

MECHANICAL JOINT C153 DUCTILE IRON


COMPACT FITTINGS
Sizes 3"
UL
For Fire Main Equipment

DUAL PURPOSE CUTTING-IN SLEEVE




Size

4
6
8
10
12

Listed

MJ x FE
Cutting-In Sleeve with Dual Purpose Accessories

For Pipe Size

Dimensions
L

4.80-5.00 O.D.
6.90-7.10 O.D.
9.05-9.30 O.D.
11.10-11.40 O.D.
13.20-13.50 O.D.

10
10
10
10
10


L 1

Shipping Wt.
Assembled

9.5
9.5
9.5
9.5
9.5

.35
.37
.39
.41
.43

33
50
67
122
157

Flanged ends are faced and drilled per ANSI/AWWA C110/A21.10. Mechanical joint ends are designed to receive both standard and oversize gray or ductile iron pipe as shown above.
MJ x FE Flange
TYPICAL CUTTING-IN SLEEVE INSTALLATIONS
Dimensions are
on inside front
VALVE
cover.
INSTALLATIONS
METER SETTINGS

Pipe Wall Thickness:


Sizes 3"-12" are recommended for ductile
iron pipe class 50 thru 56. Sizes 14" thru 24"
are recommended for ductile iron pipe class
53 thru 56.

*SET-SCREW RETAINER GLAND

DUCTILE IRON RETAINER


GLANDS

See Installations Instructions......................................................... Page




Size

3
4
6
8
10
12
14
16
18
20
24

Pressure
Rating,
psi

Gland
O.D.
B

Pipe O.D. D.I. Pipe


O.D.
Wall
A
Class

350
350
350
250
250
150
250
200
200
200
150

7.69
9.12
11.12
13.37
15.62
17.88
20.25
22.50
24.75
27.00
31.50

3.96
4.80
6.90
9.05
11.10
13.20
15.30
17.40
19.50
21.60
25.80

* Not included in AWWA C110


256772_utility catalog.pdf 10

50-56
50-56
50-56
50-56
50-56
50-56
53-56
53-56
53-56
53-56
53-56

No of
Set
Screws

4
4
6
9
12
16
20
24
24
28
32

Size of
Set
Screws

x2
x2
x2
x2
x2
x2
x2
x2
x2
x3
x3


Gland Weight
Weight w/Acces.

5
6
11
13
18
23
44
51
62
73
93

7
13
20
25
33
38
55
64
72
91
118

Mechanical Joint Retainer Glands are


designed to provide a method for restraining mechanical joint pipe and **fittings
and other standardized mechanical joints
against possible joint separation, rupture
or blow-out caused by internal water pressure.
The set screws are square-headed
with Type C knurled cup points, and are
shipped already assembled in the Glands.
They are manufactured of 4140 grade
alloy steel, and are heat treated to a Rockwall C 45/53 case hardness. Tee-head
bolts and gaskets are not included, but
may be ordered separately. Recommended torque for set screws is 75 foot pounds,
and set screws on opposite sides of the
glands should be tightened alternately.
Tee-head bolt hole size and spacing are equal to MJ Glands as shown in
AWWA C111. Standard mechanical Joint
gaskets as shown in AWWA C111 should be
used.
**Note: Not recommended for plain end fittings
10

12/15/08 8:24:21 AM

MECHANICAL JOINT DUCTILE IRON


COMPACT SPLIT REPAIR GLANDS

4" Size

6"-8"-10"-12" Sizes
MJ Compact Split Repair Glands
Size
4
6
8
10
12

Inside Diameter Bolt Circle


(+.07-.03)
(+-.06)
4.90
7.50
7.00
9.50
9.15
11.75
11.20
14.00
12.50
16.25

Weight
Lbs.
4.0
5.0
6.0
7.7
10.2

Split glands work with standard MJ gaskets and


standard T-head bolts. Glands are shipped in
halves and do not need separate bolts. T-head
bolts alone hold the halves together.

11

COMPACT

DUCTILE IRON MJ TAPPING SLEEVES

Sample Specification
Ductile ron echanical joint tapping sleeves furnished by Tyler Union Waterworks are produced in accordance
with manufacturer's standards. Chemical and physical properties of the ductile iron are in accordance
requirements of ANSI/AWWA C153/A21.53 and ASTM A536. Coatings are NSF-61, NSF-372, Annex G approved and
conform with AWWA C104. Flange recess dimensions per MSS SP-60. Tapping sleeve meets requirements of MSS SP-111
General Installation Instructions for Tyler
apping Sleeves
1. Clean pipe - insert side gasket into back half of gasket grooves. Make sure ends are flush with or slightly protrude into the end gasket seating area.
2. Bolt sleeve halves together and trim side gaskets as necessary. MAKE SURE SLEEVE WILL ROTATE FREELY ON
PIPE.
3. Install end gaskets, locating cut ends 90 from
side gasket. If pipe is maximum OD, stretch
gasket to make certain cut ends match with no
gap in between.
4. Install glands and bolts - rotate sleeve to desired
position. Be sure pipe is centered inside the sleeve.
5. Tighten gland bolts alternately, using 80 to 90
foot pounds.
6. After assembly, PRESSURE TEST ALL JOINTS BEFORE TAPPING. If additional tightening is
required, release pressure and relax tension on
gland bolts before tightening side bolts.
For Cast Iron Ductile Iron, and PVC C900 Pipe
Mechanical joint tapping sleeves - for 6" through
12" cast iron ductile iron, or PVC pipe.
Outlet flange per ANSI/AWWA C153/A21.53
Gaskets furnished meet AWWAC111 and ASTM D2000-AA.
Working pressure-250 p.s.i.
Gaskets available in SBR only
Joint deflection is not recommended

Tapping Sleeve for


Cast Iron/Ductile Iron



Size

256772_utility catalog.pdf 12

6x4
5.016
6
7.016
8x4
5.016
8x6
7.016
8
9.016
10x4
5.016
10x6
7.016
10x8
9.016
10
11.016
12x4
5.016
12x6
7.016
12x8
9.016
12x10 11.016
12
13.016

.250
.312
.250
.312
.312
.250
.312
.312
.312
.250
.312
.312
.312
.312




Dimensions
C
D

7.50
9.50
7.50
9.50
11.75
7.50
9.50
11.75
14.25
7.50
9.50
11.75
14.25
17.00

15.75
15.75
16.50
16.50
16.50
24.00
24.00
24.00
24.00
26.50
26.50
26.50
26.50
26.50

8.00
8.00
9.00
9.00
9.00
11.00
11.00
11.00
11.00
12.00
12.00
12.00
12.00
12.00

12.75
12.75
13.50
13.50
13.50
20.75
20.75
20.75
20.75
23.25
23.25
23.25
23.25
23.25

.D. Range
O

DI
Min. Max.

6.85
6.85
9.00
9.00
9.00
11.04
11.04
11.04
11.04
13.14
13.14
13.14
13.14
13.14

7.15
7.15
9.35
9.35
9.35
11.45
11.45
11.45
11.45
13.56
13.56
13.56
13.56
13.56


Weight
DI

104
108
134
140
148
236
240
246
257
273
286
292
303
320

12

12/15/08 8:24:21 AM

DUCTILE IRON C110 FULL BODY


MECHANICAL JOINT DIMENSIONS
Sizes 3" thru 12" UL Listed for Fire Main Equipment

SAMPLE SPECIFICATION (Current ANSI/AWWA revision apply)


Mechanical joint watermain fittings with accessories, 2" through 48" shall be produced of uctile ron in accordance with
and meet all applicable terms and provisions of standards ANSI/AWWA C110/A21.10
ANSI/AWWA C111/A21.11.
Ductile iron echanical oint fittings 3" through 24" shall be rated for 350 PSI working pressure. All ductile iron
mechanical joint ittings 30" through 48" shall be rated for 250 PSI working pressure. Flanged ductile-iron fittings in 24-in.
(610mm) and smaller sizes may be rated for 350 psi (2,413 kPa) with the use of special
gaskets.
NOTE - EXCEPTIONS: Mechanical Joint Fittings with flanged branches and 14" and larger caps and plugs are rated for water
pressure of 250 PSI.
NOTE - Installation per AWWA C600-10
NOTE: Fittings are cement lined and seal coated in accordance with ANSI/AWWA C104/A21.4. Fittings are also available
double cement lined, bare or epoxy coated. oated and lined fittings meet requirements of NSF-61, NSF-372, & Annex G..

NOMINAL JOINT DIMENSIONS IN INCHES - MECHANICAL JOINT FITTINGS


DIMENSIONS IN INCHES
Size

*2 2.50
3 3.96
4 4.80
6 6.90
8 9.05
10 11.10
12 13.20
14 15.30
16 17.40
18 19.50
20 21.60
24 25.80
30 32.00
36 38.30
42 44.50
48 50.80

2.50
2.50
2.50
2.50
2.50
2.50
2.50
3.50
3.50
3.50
3.50
3.50
4.00
4.00
4.00
4.00

K 1

K2

3.39
4.84
5.92
8.02
10.17
12.22
14.32
16.40
18.50
20.60
22.70
26.90
33.29
39.59
45.79
52.09

3.50
4.94
6.02
8.12
10.27
12.34
14.44
16.54
18.64
20.74
22.84
27.04
33.46
39.76
45.96
52.26

2.61
4.06
4.90
7.00
9.15
11.20
13.30
15.44
17.54
19.64
21.74
25.94
32.17
38.47
44.67
50.97

28
28
28
28
28
28
28
28
28
28
28
28
20
20
20
20













1
1
1
1

4.75
6.19
7.50
9.50
11.75
14.00
16.25
18.75
21.00
23.25
25.50
30.00
36.88
43.75
50.62
57.50

6.25
7.69
9.12
11.12
13.37
15.69
17.94
20.31
22.56
24.83
27.08
31.58
39.12
46.00
53.12
60.00

6.25
7.69
9.12
11.12
13.37
15.62
17.88
20.25
22.50
24.75
27.00
31.50
39.12
46.00
53.12
60.00

.75
.94
1.00
1.06
1.12
1.19
1.25
1.31
1.38
1.44
1.50
1.62
1.81
2.00
2.00
2.00

.62
.62
.75
.88
1.00
1.00
1.00
1.25
1.31
1.38
1.44
1.56
2.00
2.00
2.00
2.00

1.12
1.37
1.50
1.63
1.75
1.75
1.75
2.00
2.06
2.13
2.19
2.31
2.75
2.75
2.75
2.75

.31
.31
.31
.31
.31
.31
.31
.31
.31
.31
.31
.31
.38
.38
.38
.38

.63
.63
.75
.75
.75
.75
.75
.75
.75
.75
.75
.75
1.00
1.00
1.00
1.00

.44
.52
.65
.70
.75
.80
.85
.89
.97
1.05
1.12
1.22
1.50
1.80
1.95
2.20

* Not included in AWWA C110.

ACCESSORIES AND WEIGHTS




Size




Bolt
No. Size

*2
3
4
6
8
10
12
14
16
18
20
24
30
36
42
48

2
4
4
6
6
8
8
10
12
12
14
16
20
24
28
32













1
1
1
1



Wt. of Gland, Pipe
Bolt
Bolt Torque Bolts and
Barrel
Length
Ft/Lbs. Gasket, Lbs. O.D.

3
3
3
3
4
4
4
4
4
4
4
5
6
6
6
6

45-60
45-60
75-90
75-90
75-90
75-90
75-90
75-90
75-90
75-90
75-90
75-90
100-120
100-120
120-150
120-150

5
7
10
16
25
30
40
45
55
65
85
105
220
301
389
477

14" THRU 48"


GLANDS MAY
BE TAPERED

2.50
3.96
4.80
6.90
9.05
11.10
13.20
15.30
17.40
19.50
21.60
25.80
32.00
38.30
44.50
50.80

* Not included in AWWA C110.


256772_utility catalog.pdf 13

ANSI/AWWA C110/A21.10, ANSI/AWWA C111/A21.11


13

12/15/08 8:24:22 AM

DUCTILE IRON C110 FULL BODY


MECHANICAL JOINT FITTINGS

MJ x FIPT ECCENTRIC
REDUCER

Dimensions
Size
L
Weights

6x2
8x2

13
15

51
71

BENDS

90 Bends (1/4)

90 MJ x MJ (1/4)

90 MJ x FE (1/4)

90 MJ x PE (1/4)

Mechanical Joint weights


do not include Glands,
Nuts, Bolts and Gaskets.
See Joint Accessories.


Size

Dimensions
Y

*2
3
4
6
8
10
12
14
16
18
20
24
30
36
42
48

2.25
4.0
4.5
6.0
7.0
9.0
10.0
11.5
12.5
14.0
15.5
18.5
21.5
24.5
27.5
30.5

3.25
5.5
6.5
8.0
9.0
11.0
12.0
14.0
15.0
16.5
18.0
22.0
25.0
28.0
31.0
34.0


MJxMJ

Weights
MJxPE

...
13.5
14.5
16.0
17.0
19.0
20.0
22.0
23.0
24.5
26.0
30.0
33.0
36.0

16
26
56
88
123
189
268
380
552
625
862
1423
1942
2629
3410
4595

...
36
53
80
119
181
252
...
470
600
775
1301
1920
2310
...
...

MJxFE

...
...
51
75
118
168
288
...
465
577
...
1150
...
...
...
...

For sizes not found in this


section check MJ-SSB DI
fittings, pages 3 thru 11.

ANSI/AWWA C110/A21.10, ANSI/AWWA C111/A21.11


256772_utility catalog.pdf 14

14

12/15/08 8:24:22 AM

DUCTILE IRON C110 FULL BODY


MECHANICAL JOINT FITTINGS
45 Bends (1/8)

BENDS

45 MJ (1/8)

45 MJ x PE (1/8)

45 MJ x FE (1/8)


Size

Dimensions
Y

*2
3
4
6
8
10
12
14
16
18
20
24
30
36
42
48

1.96
3.62
4.81
7.25
8.44
10.88
13.25
12.06
13.25
14.50
16.88
18.12
27.75
35.00
42.25
49.50

1.8
3.0
4.0
5.0
5.5
6.5
7.5
7.5
8.0
8.5
9.5
11.0
15.0
18.0
21.0
24.0


MJ

...
11.0
12.0
13.0
13.5
14.5
15.5
15.5
16.0
16.5
17.5
19.0
23.0
26.0

16
30
53
77
110
172
222
311
364
531
655
865
1447
2435
2955
4080

Weights
MJxFE*

...
...
48
60
107
168
215
...
360
430
543
1099
...
...
...
...

MJxPE

...
...
45
69
111
167
218
...
360
455
664
825
1510
1930
...
...

* Not included in AWWA C110.

22 Bends (1/16)

22 MJ (1/16)

22 MJ x PE (1/16)

22 MJ x FE (1/16)


Size

Dimensions
Y

3
4
6
8
10
12
14
16
18
20
24
30
36
42
48

7.56
10.06
15.06
17.62
22.62
27.62
25.12
27.62
30.19
35.19
37.69
57.81
72.88
88.00
103.06

3.0
4.0
5.0
5.5
6.5
7.5
7.5
8.0
8.5
9.5
11.0
15.0
18.0
21.0
24.0


MJ

Weights
MJxFE*

11.0
12.0
13.0
13.5
14.5
15.5
15.5
16.0
16.5
17.5
19.0
23.0
26.0

30
52
77
110
156
221
300
391
527
611
986
1898
2372
3020
4170

...
...
71
107
155
215
...
315
422
...
800
...
...
...
...

MJxPE

...
...
70
109
163
224
...
365
455
575
930
1540
1970
...
...

11 Bends (1/32)

11 MJ (1/32)

11 MJ x PE (1/32)

11 MJ x FE (1/32)

256772_utility catalog.pdf 15


Size

Dimensions
Y

3
4
6
8
10
12
14
16
18
20
24
30
36
42
48

15.25
20.31
30.50
35.50
45.69
55.81
50.75
55.81
60.94
71.06
76.12
116.75
147.25
177.69
208.12

3.0
4.0
5.0
5.5
6.5
7.5
7.5
8.0
8.5
9.5
11.0
15.0
18.0
21.0
24.0


MJ

Weights
MJxFE*

11.0
12.0
13.0
13.5
14.5
15.5
15.5
16.0
16.5
17.5
19.0
23.0
26.0

30
52
65
104
171
221
305
391
525
605
996
1410
2397
3035
4190

...
...
71
105
...
215
...
367
422
...
800
...
...
...
...

MJxPE
...
...
...
...
...
...
...
...
...
...
972
1305
2185
...
...

ANSI/AWWA C110/A21.10, ANSI/AWWA C111/A21.11


15

12/15/08 8:24:22 AM

DUCTILE IRON C110 FULL BODY


MECHANICAL JOINT FITTINGS

MJ TAPPED TEE

TEES

Straight Tees and


Reducing on Branch Tees

Bullhead

MJxMJxFE

MJ Tapped Tee (2"Tap)


Size

Dimensions
L
Max. Tap

3
4
6
8
10
12

8
8
8
8
8
8

2
2
2
2
2
2


Run

Size
Run


Branch

*2
*3
3
*4
4
4
4
*6
6
6
6
6
8
8
8
8
10
10
10
10
12
12
12
12
12
14
14
*16
16
16
16
16

2
3
3
4
4
4
4
6
6
6
6
6
8
8
8
8
10
10
10
10
12
12
12
12
12
14
14
16
16
16
16
16

2
2
3
2
3
4
6
2
3
4
6
8
3
4
6
8
4
6
8
10
4
6
8
10
12
12
14
4
6
8
10
12

16

16

16

Weights

40
51
73
104
130
180

For sizes not found in this


section check MJ-SSB DI
fittings, pages thru 11.

Dimensions
Y


MJ

Weights
**MJxPExMJ **MJxMJxFE

3.25
3.25
5.5
4.8
6.5
6.5
8.0
8.0
8.0
8.0
8.0
9.0
9.0
9.0
9.0
9.0
11.0
11.0
11.0
11.0
12.0
12.0
12.0
12.0
12.0
14.0
14.0
15.0
15.0
15.0
15.0
15.0

3.25
3.25
5.5
4.8
6.5
6.5
8.0
8.0
8.0
8.0
8.0
9.0
9.0
9.0
9.0
9.0
11.0
11.0
11.0
11.0
12.0
12.0
12.0
12.0
12.0
14.0
14.0
15.0
15.0
15.0
15.0
15.0

...
...
13.5
14.5
14.5
14.5
...
...
16.0
16.0
16.0
...
17.0
17.0
17.0
17.0
19.0
19.0
19.0
19.0
20.0
20.0
20.0
20.0
20.0
22.0
22.0
23.0
23.0
23.0
23.0
23.0

21
45
58
68
77
78
112
78
112
110
119
158
155
157
175
199
...
258
268
300
318
325
335
392
396
540
585
600
615
625
645
660

...
...
...
...
...
75
...
...
...
...
120
...
...
...
170
180
...
...
...
250
315
325
335
390
396
560
570
580
590
605
620
640

...
...
...
49
...
76
...
...
...
109
141
...
...
150
182
194
229
264
245
...
323
335
372
...
476
...
...
575
605
615
...
651

15.0

15.0

23.0

740

720

730

NOTICE: Weights published in this catalog are for shipping purposes only. Actual weights may vary
because some fittings are produced in
foundries. All fittings meet the AWWA
standards to which they are designed.
For weights of specific fittings, please contact Tyler
Company.

*Not included in AWWA C110


256772_utility catalog.pdf 16

ANSI/AWWA C110/A21.10, ANSI/AWWA C111/A21.11

**Made to order only. Not Returnable


16

12/15/08 8:24:22 AM

DUCTILE IRON C110 FULL BODY


MECHANICAL JOINT FITTINGS

TEES (Con't)

Straight Tees and


Reducing on Branch Tees

Bullhead

MJxMJxFE


Run

Size
Run

18
18
18
18
20
20
20
20
20
24
24
24
24
24
24
24
24
30
30
30
30
30
30
30
30
30
36
36
36
36
36
36
36
36
36
36
36
42
42
42
42
48
48
48
48
48

18
18
18
18
20
20
20
20
20
24
24
24
24
24
24
24
24
30
30
30
30
30
30
30
30
30
36
36
36
36
36
36
36
36
36
36
36
42
42
42
42
48
48
48
48
48


Branch

6
8
12
18
6
8
12
16
20
6
8
12
14
16
18
20
24
6
8
10
12
16
18
20
24
30
6
8
10
12
14
16
18
20
24
30
36
24
30
36
42
24
30
36
42
48

13.0
13.0
13.0
16.5
14.0
14.0
14.0
18.0
18.0
15.0
15.0
15.0
15.0
15.0
22.0
22.0
22.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
25.0
25.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
28.0
28.0
23.0
31.0
31.0
31.0
26.0
26.0
34.0
34.0
34.0

* Not included in AWWA C110

Dimensions
Y

15.5
15.5
15.5
16.5
17.0
17.0
17.0
18.0
18.0
19.0
19.0
19.0
19.0
19.0
22.0
22.0
22.0
23.0
23.0
23.0
23.0
23.0
23.0
23.0
25.0
25.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
28.0
28.0
30.0
31.0
31.0
31.0
34.0
34.0
34.0
34.0
34.0

...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...


MJ

710
674
749
945
849
892
896
1095
1258
1233
1234
1256
1220
1245
1735
1720
1947
2050
2060
2075
2090
2145
2170
2205
2880
2275
2439
2444
2535
2541
2570
2585
2610
2635
2792
3545
3450
3690
4650
4880
6320
4995
5140
6280
8130
8420

Weights
**MJxPExMJ **MJxMJxFE

...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
....
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...

707
675
733
953
...
859
...
...
1168
1228
1242
1165
...
...
...
...
1795
...
...
...
...
...
...
...
...
3080
2430
...
...
2550
...
2450
...
...
2660
...
...
...
...
...
...
...
...
...
...
...

** Made to order only. Not Returnable

ANSI/AWWA C110/A21.10, ANSI/AWWA C111/A21.11


256772_utility catalog.pdf 17

17

12/15/08 8:24:22 AM

DUCTILE IRON C110 FULL BODY


MECHANICAL JOINT FITTINGS

CROSSES

WYES/LATERAL
( Not included in AWWA C110.)
*NOTE:"X" & "Z" dimensions are approximate, contact
Tyler Union for specific fitting laying lengths

*MJ x MJ x FE x FE

ALL MJ

Size
Run Branch

3
4
6
6
8
8
8
10
10
10
12
12
14
16
18
18
18
18
18
20
20
20
20
24
30
36
36
42
42

3
4
4
6
4
6
8
6
8
10
8
12
6
16
8
10
12
16
18
10
12
16
20
24
30
24
36
24
30

Dimensions
X

Z

10.0
12.0
14.5
14.5
17.5
17.5
17.5
20.5
20.5
20.5
24.5
24.5
27.0
30.0
32.0
32.0
32.0
32.0
32.0
35.0
35.0
35.0
35.0
40.5
49.0
54.0
60.0
60.0
63.0

3.0
3.0
3.5
3.5
4.5
4.5
4.5
5.0
5.0
5.5
5.5
5.5
6.0
6.5
7.0
7.0
7.0
7.0
7.0
8.0
8.0
8.0
8.0
9.0
10.0
15.0
19.5
12.0
12.0

Weights

60
90
130
145
190
205
230
330
310
435
505
490
626
1079
1073
975
1015
1135
1130
1220
1260
1375
1525
2372
3670
5390
6335
6810
7210

For sizes not found in this


section check MJ-C153 sec.
42
42
48

36
42
48

66.0
71.0
77.0

12.0
15.0
16.0

8355
9900
13150


Size
Run Branch

Dimensions
X

Y


MJ

Weights
*MJxFE

6
8
8
8
10
10
10
12
12
12
14
14
16
16
16
18
18
18
18
20
20
20
20
24
24
24
24
24
30
30
30
30
36
36
42
48

6
4
6
8
6
8
10
6
8
12
8
14
6
8
16
8
10
12
18
8
12
16
20
8
12
16
20
24
6
12
24
30
24
36
42
24

8.0
9.0
9.0
9.0
11.0
11.0
11.0
12.0
12.0
12.0
14.0
14.0
15.0
15.0
15.0
13.0
13.0
13.0
16.5
14.0
14.0
18.0
18.0
15.0
15.0
15.0
22.0
22.0
18.0
18.0
25.0
25.0
20.0
28.0
31.0
26.0

8.0
9.0
9.0
9.0
11.0
11.0
11.0
12.0
12.0
12.0
14.0
14.0
15.0
15.0
15.0
15.5
15.5
15.5
16.5
17.0
17.0
18.0
18.0
19.0
19.0
19.0
22.0
22.0
23.0
23.0
25.0
25.0
26.0
28.0
31.0
34.0

160
185
205
255
285
310
380
361
371
486
550
779
650
675
895
775
760
860
1140
951
977
1245
1440
1244
1326
1479
1965
2192
2085
2165
3180
3640
2910
4370
7145
5210

141
....
182
245
....
....
360
367
373
487
....
....
....
655
875
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....
....

48
48

36
48

34.0
34.0

34.0
34.0

6790
9380

....
....

*Not included in AWWAC110.

ANSI/AWWA C110/A21.10, ANSI/AWWA C111/A21.11


18

DUCTILE IRON C110 FULL BODY


MECHANICAL JOINT FITTINGS

REDUCERS

Laying Lengths (L)


Size

* 3x2
* 4x2
4x3
* 6x2
6x3
6x4
MJ Reducer
8x3
8x4
8x6
10x6
10x8
12x4
12x6
12x8
MJ Small End Bell Reducer 12x10
14x6
14x8
14x12
16x6
16x8
16x10
16x12
16x14
MJ Large End Bell Reducer 18x8
18x10
18x12
18x14
18x16
20x10
20x12
20x16
20x18
24x12
Plain End-Plain End Reducer
24x16
24x18
24x20
*30x16
30x18
30x20
30x24
36x20
36x24
FExMJ Reducer
36x30
42x24
42x30
42x36
48x30
48x36
48x42

Weights

MJ MJ-SEB MJ-LEB PExPE FExMJ MJxFE

6
14
7
15
7
15
9
17
9
17
9
17
11
19
11
19
11
19
12
20
12
20
14
22
14
22
14
22
14
22
16 24
16
24
16
24
18
26
18
26
18
26
18
26
18
26
19
27
19
27
19
27
19
27
19
27
20
28
20
28
20
28
20
28
24
32
24
32
24
32
24
32
30
38
30
38
30
38
30
38
36
44
36
44
36
44
42
50
42
50
42
50
48
56
48
56
48
56

14
...
15
...
15
23
17
...
17
25
17
25
19
27
19
27
19
27
20
28
20
28
22
30
22
30
22
30
22
30
24
32
24
32
24 32
26
34
26
34
26
34
26
34
26
34
27
35
27
35
27
35
27
35
27
35
28
36
28
36
28
36
28
36
32
40
32
40
32
40
32
40
38
46
38
46
38
46
38
46
44
52
44
52
44
52
50
58
50
58
50
58
56
64
56
64
56
64

MJ MJ-SEB MJ-LEB PExPE FExMJ MJxFE

...
...
24
24
24
...
...
...
...
31
30
31
...
...
7
7
37
38
37
34
34
...
...
46
43
47
...
...
...
9
55
50
55
...
...
9
9
56
60
59
57
53
...
...
84
77
70
...
...
11
11
84
82
84
...
73
11
11
94
90
93
96
84
12
12
115 116
117
...
100
12
12 142 135 130 135 130
...
...
139 131
...
...
...
14
12
148 150
153
... 145
14
12 173 168 165 168 170
14
12 194 190 178 185 188
...
16
...
...
...
...
...
...
16
...
...
...
...
...
...
16
...
...
...
...
...
...
...
250
...
...
...
...
...
...
288 248
...
...
...
...
...
300
...
...
...
...
18
18
330 304
325
...
305
...
...
370
...
...
...
...
...
19
320
...
...
...
...
...
...
388
...
...
...
...
...
19
380 355
...
...
...
...
...
450
...
...
...
...
...
19
476
...
...
...
...
...
... 410
...
...
...
...
...
...
515 420
...
...
...
...
20
578 525
510
...
...
...
...
575
...
...
...
...
...
24
610 570
...
...
...
...
...
705 665
753
...
...
...
...
789 720
...
...
...
...
...
815 775
804
...
...
...
... 1150 1040
...
1015
...
...
... 1160 1050
...
1025
...
...
...
1225 1120
... 1090
...
...
... 1360 1255 1320 1215
...
...
... 1495
... 1466
...
...
...
... 1580
...
1535 1389
...
...
... 1919 1721
... 1585
...
...
... 2060
...
...
...
...
...
... 2370
...
...
...
...
...
... 2695
...
...
...
...
...
... 3005
...
...
... ...
...
... 3370
...
...
... ...
...
...
3750
...
...
... ...

* Not included in AWWA C110

MJxFE Reducer

ANSI/AWWA C110/A21.10, ANSI/AWWA C111/A21.11


...
...
35
...
50
62
...
75
80
105
130
...
130
175
190
195
215
270
...
...
...
325
...
300
...
405
...
445
...
...
510
...
455
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...

DUCTILE IRON C110 FULL BODY


MECHANICAL JOINT FITTINGS

SOLID SLEEVES




Size

*2
3
4
6
8
10
12
16
18
20
24
30
36
42
48

Standard

Pipe
O.D.

Short
L
Weight

2.50
3.96
4.80
6.90
9.05
11.10
13.20
17.40
19.50
21.60
25.80
32.00
38.30
44.50
50.80

8.0
7.5
7.5
7.5
7.5
7.5
7.5
9.5
9.5
9.5
9.5
15.0
15.0
15.0
15.0

13
25
35
45
65
85
120
206
246
275
360
745
1047
1312
1585


Size

Long
L
Weight

12
12
12
12
12
12
12
15
15
15
15
24
24
24
24

4
6
8
10
12
16

18
36
47
65
90
115
136
281
362
404
540
1085
1502
1550
1940

* Dual Purpose
Pipe
O.D.

Short
L
Weight

4.80/5.00
6.90/7.10
9.05/9.30
11.10/11.40
13.20/13.50
17.40/17.80

7.5
7.5
7.5
...
...
...

33
46
65
...
...
...

Long
L Weight

12
12
12
12
12
15

44
63
88
111
221
385

All Sizes Use MJ Dual Purpose Gland

* Not included in AWWA C110


12" & 16" are sold assembled
NOTE: Sizes 4-10" use standard MJ Gaskets;
12" and 16" require special duo gaskets.

* Not included in AWWA C110

* MJ x PE DUAL-PURPOSE CUTTING-IN SLEEVE

With Dual-Purpose Accessories


(NOTES: Gland with cup-joint set screws available at extra cost
when specified. NOT FOR RESTRAINT.)
Currently, Tyler and Union Dual Purpose Glands are NOT
interchangeable.





Size

4
6
8
10
12

ADAPTERS

Cutting-In
Sleeve & Gland


For Use
On Pipe O.D.

4.80
6.90
9.05
11.10
13.20

5.00
7.10
9.30
11.40
13.50



L 1

12
12
12
12
12

8
8
8
8
8

4.80
6.90
9.05
11.10
13.20

Weight
Gland Gland
Only & Sleeve

6.0
10.0
16.0
25.0
30.0

72
94
122
175
235

MJ x FE


Size

3
4
6
8
10
12
16
18
20
24
30
36

Dimensions
L
Weights

8
8
8
8
8
8
8
8
8
8
10
10

30
42
62
88
120
150
257
324
365
528
760
1070

* Not included in AWWA C110.


ANSI/AWWA C110/A21.10, ANSI/AWWA C111/A21.11

256772_utility catalog.pdf 20

20

12/15/08 8:24:23 AM

DUCTILE IRON C110 FULL BODY


MECHANICAL JOINT FITTINGS

PLUGS

CAPS

OFFSETS

Solid or Tapped
Solid or Tapped

Size


Tap

*2
3
4
6
8
10
12
14
16
18
20
24
30
36
42
48

2
2
2
2
2
2
2
2
2
2
2
2
2
2
...
...

Weight
Solid Tapped

5
9
13
15
45
66
79
120
147
192
220
338
660
838
1180
1455

5
9
14
15
45
66
79
120
147
190
219
338
660
838
...
...


Size


Tap

*2
3
4
6
8
10
12
16
18
20
24
30
36
42
48

2
2
2
2
2
2
2
2
2
2
2
2
2
..
..

Weight
Solid Tapped

6
10
18
34
46
58
86
178
215
250
370
680
850
1180
1595

...
10
13
30
45
54
80
175
215
249
370
680
850
...
...

Dished Not flat as shown.


* Not included in
AWWA C110.

MJ x PE



Size

Dimensions
L1
L

Weights
MJxMJ MJxPE

4
4
4
* 4
6
6
6
* 6
8
8
8
* 8
10
10
10
12
12
*12
16
16
*20
*20

6
12
18
24
6
12
18
24
6
12
18
24
12
18
24
12
18
24
12
18
12
18

19
22
30
26
20
26
33
24
21
28
35
36
30
38
38
37
48
48
40
50
40
48

...
85
105
126
114
148
188
182
177
231
287
280
347
340
420
420
520
649
715
850
1025
1362

Dished Not flat as shown.


* Not included in
AWWA C110.

MJ x MJ

27
30
38
34
28
34
41
32
29
36
43
44
38
46
46
45
56
56
48
58
48
60

82
80
...
125
105
143
176
160
155
195
282
285
280
340
...
420
520
630
...
830
...
...

* Not included in AWWA C110.

TYTON Plug**
Solid or Tapped
Size

Tap

Weight*

4
6
8
10
12

2
2
2
2
2

.60
.65
.70
.75
.75

18
25
46
70
95

* Weights do not include accessories


** Not included in AWWA C110.
TYTON is a registured trademark
of U.S. Pipe and Foundry Company.

Solid

Tapped

Push-In Plug with Ears


(To be used with all push-in
pipe and fittings)
Size

Tap

Weight

14
16
18
20
24

2.0
2.0
2.0
2.0
2.0

101
137
177
239
311

Dished - Not flat as shown


NOTE: Blocking still required
ears for assembly only.
ANSI/AWWA C110/A21.10, ANSI/AWWA C111/A21.11

256772_utility catalog.pdf 21

21

12/15/08 8:24:23 AM

DUCTILE IRON C110 FULL BODY


MECHANICAL JOINT FITTINGS
Pipe Wall Thickness:
Sizes 3"-12" are recommended for ductile
iron pipe class 50 thru 56. Sizes 14" thru
24" are recommended for ductile iron pipe
class 53 thru 56.

*SET-SCREW RETAINER GLAND

DUCTILE IRON RETAINER


GLANDS

See Installations Instructions......................................................... Page




Size

3
4
6
8
10
12
14
16
18
20
24

Pressure
Rating,
psi

Gland
O.D.
B

Pipe O.D. D.I. Pipe


O.D.
Wall
A
Class

350
350
350
250
250
150
250
200
200
200
150

7.69
9.12
11.12
13.37
15.62
17.88
20.25
22.50
24.75
27.00
31.50

3.96
4.80
6.90
9.05
11.10
13.20
15.30
17.40
19.50
21.60
25.80

50-56
50-56
50-56
50-56
50-56
50-56
53-56
53-56
53-56
53-56
53-56

* Not included in AWWA C110

No of
Set
Screws

4
4
6
9
12
16
20
24
24
28
32

Size of
Set
Screws


Gland Weight
Weight w/Acces.

x2
x2
x2
x2
x2
x2
x2
x2
x2
x3
x3

4
5
9
13
17
20
44
54
62
76
103

8
11
16
21
26
28
55
64
72
91
118

Mechanical Joint Retainer Glands are


designed to provide a method for restraining mechanical joint pipe and fittings
and other standardized mechanical joints
against possible joint separation, rupture
or blow-out caused by internal water pressure.
The set screws are square-headed
with Type C knurled cup points, and are
shipped already assembled in the Glands.
They are manufactured of 4140 grade
alloy steel, and are heat treated to a Rockwall C 45/53 case hardness. Tee-head
bolts and gaskets are not included, but
may be ordered separately. Recommended torque for set screws is 75 foot pounds,
and set screws on opposite sides of the
glands should be tightened alternately.
Tee-head bolt hole size and spacing are equal to MJ Glands as shown in
AWWA C111. Standard mechanical Joint
gaskets as shown in AWWA C111 should
be used.
**Note: Not recommended for use on
plain end fittings

TEES

MJ GLAND

MJ x MJ x Swivel

Size


6
8x6

8
10x6
12x6
16x6
16x8
30x6

Dimensions
X

Y

8.0
9.0
9.0
11.0
12.0
15.0
15.0
18.0

10.5
11.5
11.5
13.5
14.5
17.5
17.5
24.5

Weight

150
199
210
267
346
619
649
2070


Size

Gland
Weight
Wt. Pack Gland Only

5
7
10
16
25
30
40
45
55
65
85
105
220
301
Call
Call

All weights shown include the Swivel Gland


256772_utility catalog.pdf 22

ANSI/AWWA C110/A21.10, ANSI/AWWA C111/A21.11

2
3
4
6
8
10
12
14
16
18
20
24
30
36
42
48

3
4
6
10
16
19
26
34
54
52
73
91
90
127
279
341
22

12/15/08 8:24:24 AM

DUCTILE IRON C110 FULL BODY


MECHANICAL JOINT ELLS, ADAPTERS
AND GLANDS
For Valve and Hydrant Connections
ADAPTERS
Swivel x Solid Adapter

Size by
Laying Length

Wall
Thickness

Weight*

.52
.55
.55
.55
.55
.60
.75

52
84
91
105
156
126
186

4x13
6x12
6x18
6x24
6x36
8x13
12x13

Other Swivel Hydrant


Fittings, Pages , and 7.

* Weights with Gland.

ELLS
*90 Swivel x Swivel Ell
(Not Included In AWWA C110)

Size

Wall
Thickness

6
8

.55
.60

Dimensions
C
D
E

10.5 15.5 7.10 11.12 6.90 8.02 6.0


11.5 16.5 9.20 13.37 9.05 10.17 7.0

*Weight

106
156

* With 2 Swivel Glands

SWIVEL GLAND ASSEMBLY

Used with swivel fittings, the TYLER


Swivel gland, with its rotating feature, permits the installer to meet any grade requirements regardless of bolt-hole alignment. In addition, the system permits stiff connections without braces, blocking or strapping.

Swivel Glands**
Size
Weight
12
30
** Not included in
AWWA C110.

256772_utility catalog.pdf 23

NOTE: When ordering glands


separately,
(1) Specify TYLER

UPCode Number,
(2) Description, and
(3) Size of fitting to be joined.

ANSI/AWWA C110/A21.10, ANSI/AWWA C111/A21.11


23

12/15/08 8:24:24 AM

UNION-TITE DUCTILE IRON


C153 COMPACT FITTINGS

Sizes 4"-12" UL Listed for Fire Main Equipment

SAMPLE SPECIFICATIONS (Current ANSI/AWWA revisions apply)


4" through 24" Push-On joint uctile ron ittings shall be produced in accordance with all applicable terms and provisions
of ANSI/AWWA C153/A21.53. Fittings are cement-lined and seal-coated in accordance with ANSI/AWWA C104/A21.4. Joints
shall be in accordance with
with bell sockets designed to receive pressure pipe O.D.'s as specified
in ANSI/AWWA C151/A21.51 and AWWA C900 TABLE 2. The working pressure rating shall be 350 PSI, except for wyes and
flanged-branch fittings. NOTE: Fittings are cement lined and seal coated in accordance with ANSI/AWWA C104/A21.4, also
available bare or epoxy coated. Double cement lined available. Coated and/or lined fittings meet
Thicknesses and dimensions of bell sockets and gaskets shall be in accordance with the manufacturer's design.
shall be furnished by the manufacturer. Working pressures apply to fittings only and do not apply to restraining lugs or external
restraining devices. Installation of fittings shall be per AWWA C600 and AWWA C651.
NOTE: Standard restraining lugs are provided on sizes 4" through 16" onlY. Restraining lugs are available on
18"-24" fittings provided sufficient time is available to make tooling adaptations.

EXCEPTIONS: Union-Tite fittings with flanged branches are rated for water pressure of 250 PSI but can be rated for 350 PSI with the
use of an annular ring or comparable gasket. Wye fittings over 12" are not pressure rated, call Tyler Union for information.

ADVANTAGES AND FEATURES

Push-on gasket joint uses TYTON or


gaskets
For use with Ductile iron pipe, C-900
PVC pipe, and 4"-12" pressure rated IPS diameter PVC pipe (with transition
gasket)
Deep stab joint design accommodates taper on plastic pipes
Slip joint installation eliminates T-bolts and nuts (MJ glands not needed)

BELL DIMENSIONS IN INCHES FOR UNION-TITE FITTINGS


Pipe
Size

4
6
8
10
12
14
16
18
20
24

TYTON

5.04
7.14
9.32
11.37
13.47
15.64
17.74
19.83
21.94
26.14

6.38
8.52
10.90
12.91
15.12
18.12
20.32
22.52
24.29
29.14

B.C.

7.88
10.50
12.88
14.69
17.19
19.00
21.40
...
...
...

4.16
4.29
4.78
4.98
4.98
5.40
5.40
5.40
5.40
5.65

2.25
2.25
2.25
2.25
2.25
2.25
2.25
2.25
2.25
2.50

.35
.37
.39
.41
.43
.51
.52
.59
.60
.62

registered trademark of U.S. Pipe and Foundry Company.

For Joint deflection, refer to Tyler Union product submittal 26U located on page 65 of this catalog.
NOTE: The fitting laying lengths provided are approximate, contact Tyler Union Waterworks for the
laying length of a specific fitting.

1191CR 492 Tyler, Texas 75706 (800) 527-8478
24

UNION-TITE DUCTILE IRON


C153 COMPACT FITTINGS
Sizes 4"-12" UL Listed for Fire Main Equipment

BENDS

90(1/4) UT Bends


Size

4
6
8
10
12
14
16
18
20
24

Dimensions
A
R

.35
.37
.39
.41
.43
.51
.52
.59
.60
.62

4.5
6.0
7.0
9.0
10.0
12.0
13.0
15.5
17.0
17.0

24
51
80
121
151
254
328
482
340
674

90(1/4)
UT x Flange Bends


Size T

4
6
8
10
12
14
16

3.87
5.37
6.37
8.36
9.36
10.98
12.00
14.00
15.50
15.59

45 (1/8) UT Bends

Weight

.35
.37
.39
.41
.43
.51
.52

Dimensions
B
R

4.5
6.0
7.0
9.0
10.0
12.0
13.0

imensions
D
A

R

2.0
3.0
3.5
4.5
5.5
5.5
6.0
6.5
7.0
7.5

3.31
5.72
6.93
9.34
11.75
10.85
12.02
12.36
13.59
14.69


Weight

26
42
66
101
128
143
225
209
397
492

45 (1/8)
UT x Flange Bends
Weight

6.5 3.87 31
7.0 5.37 49
9.0 6.37 74
10.0 8.36 130
12.0 9.36 158
15.5 10.98 231
16.5 12.00 233

Dimensions
A
B
R

2.0
3.0
3.5
4.5
5.5
5.5
6.0

Weight

4.0 3.31 21
5.0 5.72 42
5.5 6.93 60
6.5 9.34 93
7.5 11.75 122
8.5 10.85 162
9.5 12.02 275

22 (1/16) UT Bends
imensions
D
A

R

1.50
2.25
2.50
3.00
3.50
3.75
4.00
7.50
8.50
9.00

4.38
8.16
9.40
13.17
14.42
13.82
14.97
30.19
35.19
37.69

Dimensions
A

R

18
39
64
67
111
162
195
209
414
596

1.25
1.50
1.75
2.00
2.25
2.60
2.60
3.00
3.50
...

22 (1/16)
UT x Flange Bends
Dimensions
A
B
R

1.50
2.25
2.50
3.00
3.50
3.75
4.00

3.5
4.3
4.5
5.3
5.5
6.8
7.5

4.38
8.16
9.40
13.17
14.42
13.82
14.97

Weight

6.77
9.38
11.48
13.95
16.50
14.26
15.23
60.94
71.07
...

18
40
60
77
94
113
172
209
265
...

11 (1/32)
UT x Flange Bends
Dimensions
B
R

Weight

25
44
64
90
112
174
228

1.25
1.50
1.75
2.00
2.25
2.60
2.60

NOTE: The fitting laying lengths provided are approximate, contact Tyler Union Waterworks for the

laying length of a specific fitting.

256772_utility catalog.pdf 25

11 (1/32) UT Bends


Weight

3.30
3.50
3.75
4.00
4.30
5.75
6.10

Weight

6.77
9.38
11.48
13.95
16.50
14.26
15.23

24
30
61
80
94
170
228

25

12/15/08 8:24:25 AM

UNION-TITE DUCTILE IRON


C153 COMPACT FITTINGS

BENDS

90(1/4)
UT x PE Bends


Size T
Weight

4
6
8

.35
.37
.39

45 (1/8)
UT x PE Bends

Dimensions
B
R

4.5 10.5
6.0 12.0
...
...

Weight

3.87 35
5.37 70
...
..

Dimensions
A
B
R

2.0
3.0
3.5

8.0
9.0
9.5

22 (1/16)
UT x PE Bends
Weight

3.31 21
5.72 38
6.93 60

Dimensions
A
B
R

Weight

...
...
...
..
2.25 8.08 8.16 35
2.50 8.34 9.40 57

11 (1/32)
UT x PE Bends
A

Dimensions
B
R

...
...
...
..
1.50 7.30 9.38 36
1.75 7.55 11.48 55

TEES

256772_utility catalog.pdf 26

UT x UT x PE Tees

Size
Run Branch

6
8
12

6
6
6

.37
.39
.43

Dimensions
T1
H

.37
.37
.37

6.0
6.0
7.0

J3

Weight

11.5
12.5
15.5

60
80
140

NOTE: The fitting laying lengths provided are approximate,


contact Tyler Union Waterworks for the laying length
of a specific fitting.
26

12/15/08 8:24:25 AM

UNION-TITE DUCTILE IRON


C153 COMPACT FITTINGS

TEES

UT x UT Tees


Size

4
6x4
6
8x4
8x6
8
10x4
10x6
10x8
10
12x4
12x6
12x8
12x10
12
14x6
14x10
14x12
14
16x6
16x8
16x10
16x12
16x14
16
18x6
18x8
18x10
18x14
18x16
20x6
20x10
20x14
20x16
20x18
24x6
24x10
24x12
24x14
24x16
24x18
24x20
24

T1

.35
.37
.37
.39
.39
.39
.41
.41
.41
.41
.43
.43
.43
.43
.43
.51
.51
.51
.51
.52
.52
.52
.52
.52
.52
.59
.59
.59
.59
.59
.60
.60
.60
.60
.60
.62
.62
.62
.62
.62
.62
.62
.62

.35
.35
.37
.35
.37
.39
.35
.37
.39
.41
.35
.37
.39
.41
.43
.44
.46
.47
.51
.45
.46
.47
.48
.51
.52
.44
.45
.47
.56
.57
.44
.47
.56
.57
.59
.44
.47
.49
.56
.57
.59
.60
.62

UT x Flange Tees
Dimensions
H
J1

4.5
5.0
6.0
5.0
6.0
7.0
6.0
7.0
8.0
9.0
6.0
7.0
8.0
9.0
10.0
6.5
8.5
9.5
10.5
6.5
7.5
8.5
9.5
10.5
11.5
6.5
7.5
8.5
10.5
11.5
7.0
9.0
11.0
12.0
13.0
7.0
9.0
10.0
11.0
12.0
13.0
15.0
17.0

4.5
6.0
6.0
7.0
7.0
7.0
9.0
9.0
9.0
9.0
10.0
10.0
10.0
10.0
10.0
10.5
10.5
10.5
10.5
11.5
11.5
11.5
11.5
11.5
11.5
12.5
12.5
12.5
12.5
12.5
14.0
14.0
14.0
14.0
14.0
16.0
16.0
16.0
16.0
16.0
16.0
17.0
17.0

UT x Swivel Tees

J2

J3

UT x UT

6.5
8.0
8.0
9.0
9.0
9.0
11.0
11.0
11.0
11.0
12.0
12.0
12.0
12.0
12.0
12.5
12.5
12.5
14.0
13.5
13.5
13.5
13.5
15.0
15.0
14.5
14.5
14.5
16.0
16.0
16.0
16.0
17.5
17.5
17.5
18.0
18.0
18.0
19.5
19.5
...
...
...

...
...
9.5
...
10.5
10.5
...
12.5
12.5
...
...
13.5
13.5
...
...
14.0
...
...
...
15.0
15.0
...
...
...
...
16.13
16.13
...
...
...
17.5
...
...
...
...
19.5
...
...
...
...
...
...
...

44
68
69
73
96
116
102
113
145
155
119
141
177
160
217
176
195
196
209
266
292
232
239
349
261
348
325
344
342
362
355
369
484
610
539
385
478
663
542
566
593
628
884

Weights
UT xFlange

45
56
71
89
101
117
115
128
145
158
138
148
170
162
183
212
246
296
321
160
270
330
321
342
355
301
319
337
393
420
341
420
474
498
...
512
468
503
531
555
...
...
...

UT x Swivel

...
...
65
...
100
110
...
130
156
...
...
162
158
...
...
202
...
...
...
229
292
...
...
...
...
348
324
...
...
...
400
...
...
...
...
525
...
...
...
...
...
...

NOTE: The fitting laying lengths provided are approximate, contact Tyler Union Waterworks for the laying length of a specific fitting.

256772_utility catalog.pdf 27

12/15/08 8:24:25 AM

UNION-TITE DUCTILE IRON


C153 COMPACT FITTINGS
TAPPED TEE/CROSS
REDUCERS

UT x UT Reducers


Size

6x4
8x4
8x6
10x4
10x6
10x8
12x4
12x6
12x8
12x10
14x6
14x8
14x10
14x12
16x6
16x8
16x10
16x12
16x14
18x8
18x10
18x12
18x14
18x16
20x10
20x12
20x14
20x16
20x18
24x12
24x14
24x16
24x18
24x20

.37
.39
.39
.41
.41
.41
.43
.43
.43
.43
.51
.51
.51
.51
.52
.52
.52
.52
.52
.59
.59
.59
.59
.59
.60
.60
.60
.60
.60
.62
.62
.62
.62
.62

UT x Flange Reducers

Dimensions
T1
L

.35
.35
.37
.35
.37
.39
.35
.37
.39
.41
.44
.45
.46
.47
.45
.46
.47
.48
.51
.45
.47
.49
.56
.57
.47
.49
.56
.57
.59
.49
.56
.57
.59
.60

4.0
5.0
4.0
7.0
5.0
4.0
9.0
7.0
5.0
4.0
9.0
7.0
5.0
4.0
11.0
9.0
7.0
5.0
4.0
14.0
12.0
10.0
8.0
7.0
14.0
12.0
10.0
8.0
7.0
16.0
14.0
12.0
10.0
8.0

6.0
7.0
6.0
9.0
7.0
6.0
11.0
9.0
7.0
6.0
11.0
9.0
7.0
6.0
13.0
11.0
9.0
7.0
6.0
16.0
14.0
12.0
11.5
10.5
16.0
...
13.5
11.5
...
18.0
17.5
15.5
...
...

256772_utility catalog.pdf 28

32
46
49
47
47
53
74
58
74
82
84
85
87
104
94
104
130
152
139
142
151
167
217
202
180
205
233
250
248
246
281
380
390
421

32
46
47
55
59
61
78
75
74
95
121
128
127
144
133
141
158
172
196
157
175
215
234
246
234
...
249
272
...
262
315
328
...
...

4
6
8
10
12
14
16
20

Dimensions
T
L

.35
.37
.39
.41
.43
.51
.52
.60

6.0
6.0
6.0
6.0
6.0
7.0
7.0
6.0

Weight

28
36
54
71
102
113
115
295

UT x Tapped Tee/Crosses


Size

4
6
8
10
12

Dimensions
Max Tap

Weight

.35
.37
.39
.41
.43

3.0
3.5
3.5
3.5
3.5

6.0
6.0
6.0
6.0
6.0

27
38
59
72
92

CAPS AND PLUGS

UT x Flange Adaptor


Size

Weights
UT x UT UT xFlange

Solid Cap

Solid Plug

2" Tapt Cap

2" Tapt Plug



Size

UT Caps and Plugs*


T1

Dimensions
T2
L

4
.48
.50
5.25
6
.48
.50
5.25
8
.51
.53
5.25
10
.53
.56
5.25
12
.55
.62
5.25
*Restraining lugs (ears) available.

Weights
Cap
Plug

15
20
35
50
75

8
23
32
38
49

NOTE: The fitting laying lengths provided are approximate, contact Tyler Union Waterworks
for the laying length of a specific fitting.

28

12/15/08 8:24:26 AM

UNION-TITE DUCTILE IRON


C153 COMPACT FITTINGS

WYES

CROSSES

UT Wyes


Size

8x4
10x4
10x6
10x8
10
12x4
12x6
12x8
12x10
12
14x6
14x8
14x10
14
16x6
16x8
16x12
16

.39
.41
.41
.41
.41
.43
.43
.43
.43
.43
.51
.51
.51
.51
.52
.52
.52
.52

Dimensions
T1
P

Weights

.35
.35
.37
.39
.41
.35
.37
.39
.41
.43
.44
.45
.46
.51
.45
.46
.48
.52

0.0
0.0
1.0
2.5
4.0
0.0
1.5
1.5
3.0
5.0
0.0
1.5
3.0
6.0
0.0
0.5
3.5
6.5

89
141
151
175
200
178
201
224
240
289
236
255
325
475
281
304
346
380

13.5
15.0
16.0
17.0
18.0
16.5
18.5
18.5
20.0
20.0
19.5
21.0
22.5
25.0
21.0
22.5
25.0
28.0

UT Crosses


Size

T1

Dimensions
H

Weights

.37
.37
.39
.35
.39
.43
.44
.45
.46
.47
.51
.45
.46
.47
.48
.51
.52

6.0
6.0
7.0
6.0
8.0
10.0
6.5
7.5
8.5
9.5
10.5
6.5
7.5
8.5
9.5
10.5
11.5

6.0
7.0
7.0
9.0
10.0
10.0
10.5
10.5
10.5
10.5
10.5
11.5
11.5
11.5
11.5
11.5
11.5

88
117
156
116
240
241
189
204
222
239
270
234
323
268
274
322
317

6
8x6
8
10x4
12x8
12
14x6
14x8
14x10
14x12
14
16x6
16x8
16x10
16x12
16x14
16

TYTON GASKETS

Tyton Joint IPS Transition and Regular Gasket



Dimensions


Transition (IPS) Regular (Ductile)
Size
A
B(1%)

B*

4
6
8
10
12

5.74
7.86
10.15
12.10
14.31

4.18
6.31
8.32
10.30
12.70

4.68
6.73
8.85
10.87
12.95

1.00
1.10
1.29
1.36
1.45

NOTICE: Weights published in this


catalog are for shipping purposes only.
Actual weights may vary because some
fittings are produced in both foundries.
All fittings are made in the USA and meet
the AWWA standards to which they are
designed.
For weights of specific fittings, please
contact
Tyler Union Waterworks
representative.

TYTON is a registered trademark of


U.S. Pipe and Foundry Company.

256772_utility catalog.pdf 29

NOTE: The fitting laying lengths provided are approximate, contact Tyler Union Waterworks for the laying length of a specific fitting.

12/15/08 8:24:26 AM

DUCTILE IRON C110


FLANGED FITTINGS
Sizes 3" thru 12" UL Listed for Fire Main Equipment

SAMPLE SPECIFICATION (Current ANSI/AWWA revisions apply)


Flanged fittings, 2" through 48" shall be manufactured of ductile Iron in accordance with all applicable terms and provisions of
standards ANSI/AWWA C110/A21.10. Flange surfaces shall be faced and drilled in accordance with ANSI Class 125, B16.1.
All ductile ron langed fittings shall be rated for water pressure of 250 PSI. Flanged ductile-iron fittings in 24-in. (610 mm)
and smaller sizes may be rated for 350 psi (2,413 kPa) with the use of special gaskets. NOTE: Fittings are
and seal coated in accordance with ANSI/AWWA C104/A21.4. Fittings are also available prime coated, bare or epoxy coated.
All coated fittings meet requirements of NSF-61, NSF-372, and Annex G. Interiors of fittings shall be lined and seal coated in
accordance with ANSI/AWWA C104/A21.4. Cement mortor lining for uctile iron pipe and fittings for
ater unless otherwise

FLANGE DETAILS
Nominal
Pipe Size
Inch

NOTE: No flange joint


material furnished.

2
3
4
6
8
10
12
14
16
18
20
24
30
36
42
48


Flange
O.D.
6
7.5
9
11
13.5
16
19
21
23.5
25
27.5
32
38.75
46
53
59.50

Dia. of
Bolt
Circle
4.75
6
7.5
9.5
11.75
14.25
17
18.75
21.25
22.75
25
29.5
36
42.75
49.50
56.00

Flange
Thickness
T
.62
.75
.94
1.00
1.12
1.19
1.25
1.38
1.44
1.56
1.69
1.88
2.12
2.38
2.62
2.75

Bolt Hole
Diameter
.75
.75
.75
.875
.875
1.00
1.00
1.125
1.125
1.25
1.25
1.375
1.375
1.675
1.625
1.625

Number
of Bolts

Bolt Dia.
and Lengths

4
4
8
8
8
12
12
12
16
16
20
20
28
32
36
44

x 2
x 2
x 3
x 3
x 3
x 4
x 4
1 x 4
1 x 4
1 x 5
1 x 5
1 x 5
1 x 6
1x7
1x7
1x8

NOTE: Drilling templates are in multiples of four, so that fittings may be made to face in any
quarter. Bolt holes shall straddle the center line.

256772_utility catalog.pdf 30

30

12/15/08 8:24:26 AM

DUCTILE IRON C110


FLANGED FITTINGS
Sizes 3" thru 12" UL Listed for Fire Main Equipment

BENDS
Note: Base Bends are on page 33 and 34, reducing and long radius 90 bends are on page 33.

90Bends (1/4)



Size

2
3
4
6
8
10
12
14
16
18
20
24
30
36
42
48

Dimensions

R
A
Weight

3.0
4
4.5
6
7
9
10
11.5
12.5
14
15.5
18.5
21.5
24.5
27.5
30.5

256772_utility catalog.pdf 31

4.5
5.5
6.5
8
9
11
12
14
15
16.5
18
22
25
28
31
34

14
26
44
67
115
164
236
330
478
527
878
1085
1755
2135
3055
4095

45 Bends (1/8)
Dimensions
R
A

...
3.62
4.81
7.25
8.44
10.88
13.25
12.06
13.25
14.5
16.88
18.12
27.75
35.00
42.25
49.50


Weight

...
...
3
20
4
36
5
57
5.5
105
6.5
131
7.5
196
7.5
245
8
315
8.5
422
9.5
485
11
730
15 1355
18 1755
21 2600
24 3580

221/2 Bends (1/16)


Dimensions
R

A

...
7.56
10.06
15.06
17.62
22.62
27.67
25.12
27.62
30.19
35.19
37.69
57.81
72.88
88.00
103.06

...
3
4
5
5.5
6.5
7.5
7.5
8
8.5
9.5
11
15
18
21
24


Weight

...
22
35
64
90
130
194
250
315
402
505
528
1385
1790
2665
3665

111/4 Bends (1/32)


Dimensions
R

A

...
15.25
20.31
30.5
35.5
45.69
55.81
50.75
55.81
60.94
71.06
76.12
116.75
147.25
177.69
208.12

...
3
4
5
5.5
6.5
7.5
7.5
8
8.5
9.5
11
15
18
21
24

Weight

...
20
40
56
90
130
193
245
315
385
505
760
1395
1805
2680
3695

31

12/15/08 8:24:26 AM

DUCTILE IRON C110


FLANGED FITTINGS

TEES, REDUCING TEES, CROSSES

Straight Tees, Reducing


on Branch Tees


Run

Size
Run

2
3
3
4
*4
4
4
*4
*6
*6
*6
6
6
6
6
*8
*8
*8
8
8
8
8
*8
*8
*10
*10
*10
*10
*10
10
10
10
10
10
* 12
*12
*12

2
3
3
3
4
4
4
4
4
4
6
6
6
6
6
6
6
6
8
8
8
8
8
8
6
6
8
8
8
10
10
10
10
10
6
6
8

256772_utility catalog.pdf 32


Branch

2
2
3
3
2
3
4
6
4
6
2
3
4
6
8
4
6
8
3
4
6
8
10
12
6
10
6
8
10
4
6
8
10
12
6
8
6

*Reducing
on Run

Dimensions
H

J

4.5
5.5
5.5
6.5
6.5
6.5
6.5
8.0
8.0
8.0
8.0
8.0
8.0
8.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
11.0
12.0
13.0
13.0
13.0
13.0
13.0
11.0
11.0
11.0
11.0
12.0
14.0
14.0
14.0

4.5
5.5
5.5
5.5
6.5
6.5
6.5
8.0
8.0
8.0
8.0
8.0
8.0
8.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
11.0
12.0
13.0
13.0
13.0
13.0
13.0
11.0
11.0
11.0
11.0
12.0
14.0
14.0
14.0

*Reducing on
Run and Branch
Weights
Tee
Cross

20
35
42
53
55
54
60
88
96
100
85
85
90
98
138
130
148
154
128
155
148
179
225
277
278
308
298
278
325
239
215
254
265
337
346
362
355

...
51
...
...
76
87
...
...
...
...
96
112
141
...
...
...
...
140
155
172
195
...
...
...
...
...
...
...
220
242
294
330
...
...
...
...

*Bullhead
Tees


Run

Size
Run

*12
*12
*12
12
12
12
12
12
12
12
12
*14
14
14
14
14
14
*16
16
16
16
16
16
16
18
18
18
18
18
18
18

8
8
10
10
10
10
12
12
12
12
12
14
14
14
14
14
14
16
16
16
16
16
16
16
18
18
18
18
18
18
18


Branch

8
12
6
8
10
12
4
6
8
10
12
4
6
8
10
12
14
4
6
8
10
12
14
16
6
8
10
12
14
16
18

Straight and
Reducing Crosses

Dimensions
H

J

12.0
12.0
14.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
14.0
14.0
14.0
14.0
14.0
14.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
13.0
13.0
13.0
13.0
16.5
16.5
16.5

12.0
12.0
14.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
14.0
14.0
14.0
14.0
14.0
14.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
15.5
15.5
15.5
15.5
16.5
16.5
16.5

Weights
Tee
Cross

375
420
390
400
420
440
322
297
346
394
369
410
420
435
450
470
500
525
573
555
565
590
610
635
780
609
585
638
808
760
865

...
...
...
...
...
...
310
326
351
415
438
...
450
475
...
555
595
...
565
590
620
665
...
755
...
...
...
706
...
...
915

* Not included in AWWA C110

H and J dimensions are two-inches longer than straight


tees.

*NOTE: "H" & "J" dimensions are approximate, contact


Tyler Union for laying length of a specific fitting

32

12/15/08 8:24:27 AM

DUCTILE IRON C110


FLANGED FITTINGS

TEES, REDUCING TEES, CROSSES (Con't)



Run

Size
Run

20
20
20
20
20
20
20
20
24
24
24
24
24
24
24
24
24
*30
30
30
30
30
36
36
36
42
42
42
42
48
48
48
48
48

20
20
20
20
20
20
20
20
24
24
24
24
24
24
24
24
24
30
30
30
30
30
36
36
36
42
42
42
42
48
48
48
48
48


Branch

6
8
10
12
14
16
18
20
6
8
10
12
14
16
18
20
24
6
12
18
24
30
24
30
36
24
30
36
42
24
30
36
42
48

Dimensions
H

J

14.0
14.0
14.0
14.0
14.0
18.0
18.0
18.0
15.0
15.0
15.0
15.0
15.0
15.0
22.0
22.0
22.0
18.0
18.0
18.0
25.0
25.0
20.0
28.0
28.0
23.0
31.0
31.0
31.0
26.0
26.0
34.0
34.0
34.0

17.0
17.0
17.0
17.0
17.0
18.0
18.0
18.0
19.0
19.0
19.0
19.0
19.0
19.0
22.0
22.0
22.0
23.0
23.0
23.0
25.0
25.0
26.0
28.0
28.0
30.0
31.0
31.0
31.0
34.0
34.0
34.0
34.0
34.0


Tee

773
720
735
816
770
950
965
1005
1089
1060
1020
1125
1050
1070
1534
1510
1685
1725
1801
1852
2475
2615
2255
3000
3160
3245
4125
5360
5580
4385
4455
5555
7195
7385

Weights
Cross

...
...
...
820
...
1065
...
1175
...
...
...
1100
1125
1160
...
1695
1850
...
...
...
2695
2985
...
...
6740
...
...
...
...
...
...
...
...
...

* Not included in AWWA C110

*NOTE:"D", "H", "J", "X", "Y" and "L" dimensions are approximate,
contact Tyler Union for diameter or laying length of a
specific fitting.

256772_utility catalog.pdf 33

FLANGE AND FLARE

*Flange and Flare 90 Ell



Size

3
4
6
8
10
12
14
16
18
20
24
30
36

Dimensions
D
X
Y

7.5
9.0
11.0
13.5
16.0
19.0
21.0
23.5
25.0
27.5
32.0
38.8
48.0

5.5
6.5
8.0
9.0
11.0
12.0
14.0
15.0
16.5
18.0
22.0
25.0
28.0

8.5
9.5
12.0
13.0
15.0
16.0
22.0
23.0
24.5
26.0
30.0
38.0
38.0

Weight

26
39
73
110
171
253
450
545
675
860
1195
2070
2900

*Flange and Flare Piece



Size

Dimensions
D L Weight

3 7.25 8
21
4 9.00 8
30
6 11.00 8
44
8 13.50 10
75
10 16.00 10 113
12 19.00 12 155
14 21.00 16 225
16 23.50 16 330
18 25.00 16 355
20 27.50 18 465
24 32.00 18 598
30 38.75 24
900
36 46.00 24 1200
*Flange by Flare not included
in AWWA C110

33

12/15/08 8:24:27 AM

DUCTILE IRON C110


FLANGED FITTINGS

REDUCERS

Concentric Reducer

*Eccentric Reducer


Size
Dimensions Wts
D
D1
L


Size
Dimensions Wts
D
D1
L


Size
Dimensions Wts
D
D1
L

3
4
4
6
6
6
6
8
8
8
8
10
10
10
12
12
12
12
14
14
14
14
16
16
16
16
16

18
18
18
18
18
20
20
20
20
20
24
24
24
24
24
30
30
30
30
42
42
42
48
48
48

4
3
7
30
18
6
3
9
45
18
6
4
9
52
20
8
4
11
70
20
8
6
11
80
20


20



20

24


24

24


24

24

30

30

30

30


36

36
42
42
42
48
48
48

2
2
3
2
3
4
5
3
4
5
6
4
6
8
4
6
8
10
6
8
10
12
6
8
10
12
14

6
7
7
9
9
9
9
11
11
11
11
12
12
12
14
14
14
14
16
16
16
16
18
18
18
18
18

17
23
29
30
44
46
56
61
63
70
75
98
107
116
119
130
152
178
165
185
205
235
210
230
255
285
315

8
10
12
14
16
10
12
14
16
18
12
14
16
18
20
16
18
20
24
24
30
36
30
36
42

19
19
19
19
19
20
20
20
20
20
24
24
24
24
24
30
30
30
30
42
42
42
48
48
48

265
290
320
350
405
418
465
430
445
470
608
565
610
645
695
945
970
1144
1155
1810
2060
2345
2615
2940
3320


Size
Dimensions Wts
D
D1
L

14
16
10
12
14
16
18
12
14
16
18
20
16
18
20
24
24
30
24
30
36
30
36
42

19
19
20
20
20
20
20
24
24
24
24
24
30
30
30
30
36
36
42
42
42
48
48
48

350
385
350
370
402
449
455
535
570
614
645
695
778
810
870
970
1425
2120
2340
2060
2345
2625
2950
3320

NOTE: Eccentric
Reducers not included in
AWWA C110

NOTE: Eccentric Reducers


Offset
1/2 D minus 1/2 D1=Offset
Example:
6x3 Ecc.Reducer
3-1 = 1" Offset

34

DUCTILE IRON C110


FLANGED FITTINGS
*BENDS

* WYES/LATERALS

*45 Wye
Size
Run Branch

3
4
4
6
6
8
8
8
10
10
10
10
12
12
12
12
12
14
14
14
14
14
16
16
16
16
16
16
18
18
18
18
18
18
20
20
20
20
20
24
36

3
3
4
4
6
4
6
8
4
6
8
10
4
6
8
10
12
6
8
10
12
14
6
8
10
12
14
16
8
10
12
14
16
18
10
12
14
16
20
24
36

Dimensions
H J
Weight

10
3
49
12
3
68
12
3
76
14.5
3.5 106
14.5
3.5 131
17.5
4.5 153
17.5
4.5 188
17.5
4.5 201
20.5
5
232
20.5
5
288
20.5
5
333
20.5
5
300
24.5
5.5 355
24.5
5.5 370
24.5
5.5 395
24.5
5.5 420
24.5
5.5 460
27
6
500
27
6
525
27
6
555
27
6
600
27
6
640
30
6.5 655
30
6.5 680
30
6.5 715
30
6.5 755
30
6.5 800
30
6.5 850
32
7
820
32
7
855
32
7 1003
32
7
940
32
7
990
32
7 1035
35
8 1095
35
8 1130
35
8 1170
35
8 1220
35
8 1345
40.5
9 2020
60
19.5 5740

* Not included in AWWA C110


*90 Reducing
Bend (1/4)

*True Wye
Size
Dimensions
Stem Branch X
Y Weight

4
6
6
8
8
10
10
10
12
12
12
16

4
4
6
6
8
6
8
10
8
10
12
16

6.5
8.0
8.0
9.0
9.0
8.0
9.0
11.0
9.0
11.0
12.0
15.0

3.0
3.5
3.5
4.5
4.5
5.0
5.0
5.0
5.5
5.5
5.5
6.5

49
75
84
134
125
140
155
220
210
240
315
520

Dimensions

Size
A
Weight

Size

4x3
6.5
6x4
8.0
8x4
9.0
8x6
9.0
10x6 11.0
10x8 10.0
12x6 12.0
12x8 12.0
12x10 12.0
14x6 14.0
14x8 14.0

* Not included in AWWA C110

*90 Long Radius Bend


(1/4)

35
65
88
96
126

151

172

191

218
230
240

3
6.25
4
7
6
9.5
8 14
10 16.5
12 17
14 19
16 21.5
18
.....
20 .....
24 .....

* Not included in

*BASE BENDS

Base Bends
are made
to order
only, not
returnable.
Bases are
furnished
faced and
drilled.

3
4
6
8
10
12
14
16
18
20
24
30
36



Support
Dimensions
Pipe
X
S
U
Size

4.88
5.50
7.00
8.38
9.75
11.25
12.50
13.75
15.00
16.00
18.50
23.00
26.00

7.75
32
9
46
11.5
83
14
140
16.5 252
19
310
21.5 475
24
630
26.5
840
29
1080
34
1640

BASE TEES

90 Base Bend (1/4) *90 Long Radius Base Bend (1/4)




Size

Dimensions
A
Weight

5
6
7
9
9
11
11
11
13.5
13.5
13.5
16
19

.50
.50
.62
.88
.88
1.00
1.00
1.00
1.12
1.12
1.12
1.15
1.15

1.5
2.0
2.5
4.0
4.0
6.0
6.0
6.0
8.0
8.0
8.0
10.0
10.0

Base Tees


90

Weight
90LR

Tee

38
50
83
142
210
300
400
505
645
805
1215
1945
2395

41
60
100
180
315
427
580
740
...
...
...
...
2895

47
76
115
195
315
450
570
710
900
1125
1927
...
...

* Not included in AWWA C110

*NOTE: "A", "H", "J", "X", & "Y" dimensions are approximate, contact Tyler Union for laying length or base height of a specific fitting

256772_utility catalog.pdf 35

35

12/15/08 8:24:27 AM

DUCTILE IRON C110


FLANGED FITTINGS

* REDUCING BASE BENDS

* FLANGE SLUDGE
SHOE

Base Under
Large End


Size

Base Under
Small End

Dimensions
X

S

4x3
5.5
6x4
7
8x4
8.38
8x6
8.38
10x6
9.75
10x8
9.75
12x6
11.25
12x8
11.25
12x10 11.25

6
7
9
9
9
9
11
11
11

Weight

.50
.62
.88
.88
.88
.88
1.00
1.00
1.00

45
75
118
135
175
184
230
255
285

* Not included in AWWA C110


NOTE: X dimensions are identical on Baseunder-large-end and Base-under-small-end.
S dimensions are determined by the largest
fitting opening.

FLANGES (COMPANION FLG)

Flange for Steel Pipe


Reducing Flange for Steel Pipe

Flange for DI Pipe


Reducing Flange for DI Pipe

Nom.
Diameter
Inches

Flange Sludge Shoe


Weight

3 5.75 12
6
28
4 7.00 12
6
35
6 7.87 12
6
45
8 10.12 12
6
69
10 12.25 12
6
88
12 15.25 12
6
120
* Not included in AWWA C110







Size

Base Drilling Details

Dimensions
D
X
Y

Dimensions - Inches

Bolt Hole Number
BC
Diameter
of Bolts

3
4
6
8
10
12
14
16
18
20
24
30
36
42
48

3.88
4.75
5.50
7.50
7.50
9.50
9.50
9.50
11.75
11.75
11.75
14.25
17.00
21.25
22.75

5/8
3/4
3/4
3/4
3/4
7/8
7/8
7/8
7/8
7/8
7/8
1
1
1-1/8
1-1/4


Size

Dimensions
Y


Steel


DI

2
2
3
4
6
8
10
12
14
16
18
20
24
30
36
42
48

6
7
7.5
9
11
13.5
16
19
21
23.5
25
27.5
32
38.75
46.00
53.00
59.50

.62
.69
.75
.94
1.00
1.12
1.19
1.25
1.38
1.44
1.56
1.69
1.88
2.12
2.38
2.62
2.75

1
1.13
1.19
1.31
1.56
1.75
1.94
2.19
2.25
2.50
2.69
2.88
3.25
...
...
...
...

4.75
5.50
6.00
7.50
9.50
11.75
14.25
...
...
...
...
...
...
...
...
...
...

4
8
7
12
21
28
49
61
...
...
...
...
...
...
...
...
...

...
...
6
11
14
34
33
52
72
90
105
115
160
255
...
...
...

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

eight
W
Blind Blind Tap

...
...
8
15
28
45
62
72
110
165
192
249
375
580
790
1175
1585

...
...
8
15
28
45
62
87
110
165
190
250
370
580
...
...
...

NOTE: All flanges conform to ANSI/AWWA C110/A21.10 Standards.


(If Required)

Under 12" Blind Flange


With Optional 2" Taps

12" and Larger Blind Flange


With Optional 2" Taps

DI Reducing Flange
Threaded For Steel Pipe

Size

4x3
6x4
8x4
8x6
10x6
12x6
10x8
12x10

DI Reducing Flange
Threaded For Cast Iron Pipe

Tap x O.D.

Weight

Size

Tap x O.D.

3x9
4x11
4x13
6x13
6x16
6x19
8x16
10x19

16
25
44
31
50
60
55
72

4x3
6x4
8x4
8x6
10x8
12x8

3x9
4x11
4x13
6x13
8x16
8x19

*NOTE: "X" and "Y" dimensions are approximate, contact Tyler Union for these dimensions of a specific fitting

256772_utility catalog.pdf 36

Weight

16
25
40
35
50
85

36

12/15/08 8:24:28 AM

DUCTILE IRON C110


FLANGED FITTINGS
Ductile Iron Adapter Flange

ADAPTER FLANGES
(EZ OR UNI)


Size

Ductile Iron
Pipe OD
+.06 or -.06

3
4
6
8
10
12

3.96
4.80
6.90
9.05
11.10
13.20

D
+.06
-.04

4.94
6.02
8.12
10.27
12.34
14.44

F
+.07
-.03

Weight

4.06
4.90
7.00
9.15
11.20
13.30

.94
1.00
1.06
1.12
1.19
1.25

7
10
14
22
30
40

All set screws are 5/8" 80 lb. torque head.


Wall Thickness Note: Recommended for Ductile Iron Pipe
Class 53 thru Class 56.

See Index for Installation Instructions



Rated

Working
Size Pressure

No. of

Set
Bolt
Screws Circle

3
4
6
8
10
12

4
4
8
8
12
12

250
250
250
250
250
150

6.00
7.50
9.50
11.75
14.25
17.00

No. of

Bolt &
Size
Nuts of Bolt

4
8
8
8
12
12

Bolt
Hole
Dia.

x2
x3
x3
x3
x4
x4

1
1

**Location of Tapped Holes forrains


AWWA C110 Flanged Fittings

Fittings can be supplied with taps sized and located to ANSI B16.1
and MSS-SP-45. Specify fitting size, tap location by letter (refer to
drawings) and tap size by NPT dimension, on order.

Note:

a boss is always required at y OR v on


straight and reducing sizes of 90-degree
elbows, and on tapered sides of reducers.

Fitting Size Maximum Tap

Fitting
itting
F
Size

Size

Maximum
TapTap
Maximum
Without
Boss
Without
Boss

3"........................ 1/2"
4" - 6"................. 3/4"
8"........................ 1-1/4"
10" - 16"............... 1-1/2"
18" - 36"............... 2"

ADDER for Tapricing


For pricing of tapped outlets, tapped for studs, and extra heavy 250 Class C-110 Flanged fittings refer to List Price Guide or consult
your Tyler Union Inside Sales Representative for current pricing

256772_utility catalog.pdf 37

37

12/15/08 8:24:28 AM

**6850 SERIES
CAST IRON TWO-PIECE VALVE BOXES

for 4" through 12" valves, 51/4" shaft, screw-type

TYLER UNION valve boxes are available either pre-assembled or as


individual tops and bottoms. For assembled boxes, The UPC codes
shown represent a combination of one top and one bottom in the
sizes shown. For unassembled boxes, the UPC code represents only
a top or a bottom, not a complete box. Therefore, unassembled
boxes require ordering tops and bottoms separately.
**NOTE: Domestic Valve Boxes available in Heavy Duty Only

Non-Domestic available in Standard or Heavy Duty

Box Assembled
(Less Lid)


Box (Components)

461-S
462-S
562-S
563-S
564-S
662-S
664-S
665-S
666-S
668-S

Extension *(D-HD)UPCode *(ND-HD)UPCode


Height
670610
670610
Wt

(10T + 15B)
19-22 145776
(10T + 24B)
27-32 145783
(16T + 24B)
27-37 145790
(16T + 30B)
33-43 145752
(16T + 36B)
39-50 145806
(26T + 30B)
36-52 145769
(26T + 36B)
39-60 145813
(26T + 24B)
39-63 375296
(26T+24B+60 Ext) 53-71 145820
(26T+36B+60 Ext) 64-82 145837

NOTE: D=Domestic

ND=Non-Domestic

502098 50
502104 58
502111 71
-----
78
502128 85
----
93
----
100
----
87
502135 128
----
136

HD=Heavy Duty Weight

*(ND-Std.)UPCode
670610
Wt

112280 35
112297 43
112303 50
112310 60
112327 66
112341 76
112358 82
---
--112365 95
112372 111

Lids marked WATER will ship


unless otherwise specified:
Also available 5" Drop Lids"
1)WATER OMA 2)SEWER 3)MWW
4)PLAIN 5)GAS 6)REUSE

Note: Special Lettering Available



Contact Tyler Union for

Setup Charge

Std.=Standard Weight

39

6850 SERIES
CAST IRON TWO-PIECE VALVE BOXES

for 4" through 12" valves, 51/4" shaft, screw-type

SEPARATE UPCODES for VALVE BOX TOPS ONLY (Less Lids)


TOP
Length

Box

**(D-HD) UPCode
670610


Wt

144939
144939
144946
144946
144946
144953
144953
144953
144953

22
22
36
36
36
51
51
51
51

461-S (10T)
462-S (10T)
562-S (16T)
563-S (16T)
564-S (16T)
662-S (26T)
664-S (26T)
666-S (26T)
668-S (26T)
**NOTE: D=Domestic

ND=Non-Domestic

**(ND-HD) UPCode
670610
Wt

502142
502142
502159
502159
502159
502166
502166
502166
502166

**(ND-Std.) UPCode
670610

Wt

22
22
36
36
36
51
51
51
51

112402
112402
112419
112419
112419
112426
112426
112426
112426

15
15
22
22
22
38
38
38
38

HD=Heavy Duty Weight

Std.=Standard Weight

EXTENSIONS

Height **(D-HD) UPCode **(ND-Std.) UPCode


Increase
670610
Wt
670610
Wt

Item/Description

#58 Screw-Type
#59 Screw-Type
#60 Screw-Type

14
18
24

145141
145158
145059

29
30
37

---
---
112389

----29

60 Extension

58 and 59 Extension

SEPARATE UPCODES for VALVE BOX BOTTOMS ONLY



Box

Bottom **(D-HD)UPCode
Length
670610

**(ND-HD)UPCode

**(ND-Std.)UPCode

Wt

670610

Wt

670610

Wt

461-S
462-S
562-S
563-S
564-S
662-S
664-S
666-S
668-S

(15B)
(24B)
(24B)
(30B)
(36B)
(30B)
(36B)
(24B)
(36B)
(48B)
(60B)

27
35
35
42
49
42
49
35
49
---
---

502173
502180
502180
502197
502203
502197
502203
502180
502203
---
---

27
35
35
42
49
42
49
35
49
---
---

112242
112259
112259
112266
112273
112266
112273
112259
112273
452737
452744

20
28
28
38
44
38
44
28
44
62
85

145004
145011
145011
144991
145028
144991
145028
145011
145028
---
---

**Note: D=Domestic

ND=Non-Domestic

HD=Heavy Duty Weight

Std.=Standard Weight

40

6855 SERIES
CAST IRON TWO-PIECE VALVE BOXES

for 4" through 12" valves, 51/4" shaft, slip-type

TYLER UNION valve boxes are available either pre-assembled or as


individual tops and bottoms. For assembled boxes, The UPC codes
shown represent a combination of one top and one bottom in the
sizes shown. For unassembled boxes, the UPC code represents only
a top or a bottom, not a complete box. Therefore, unassembled
boxes require ordering tops and bottoms separately.
**NOTE: Domestic Valve Boxes available in Heavy Duty Only

Non-Domestic available in Standard or Heavy Duty

Box Assembled
(Less Lid)


Box (Components)

461-A
462-A
562-A
563-A
564-A
662-A
664-A
666-A
668-A

Extension *(D-HD)UPCode *(ND-HD)UPCode *(ND-Std.)UPCode


Height
670610
670610
Wt
670610
Wt

(10T + 15B)
19-22 145844
(10T + 24B)
27-32 145831
(16T + 24B)
27-37 145868
(16T + 30B)
33-43 145714
(16T + 36B)
39-50 145875
(26T + 30B)
36-52 145721
(26T + 36B)
39-60 145882
(26T+24B+60 Ext) 53-71 145899
(26T+36B+60 Ext) 64-82 145905

NOTE: D=Domestic

ND=Non-Domestic

502234 55
----
65
502241 72
----
81
502258 83
----
97
502265 99
----
124
----
135

HD=Heavy Duty Weight

112099 34
112105 46
112112 55
112129 67
112136 72
112143 83
112150 88
112167 108
112181 125

Lids marked WATER will ship


unless otherwise specified:
Also available 5" Drop Lids"
1)WATER OMA 2)SEWER 3)MWW
4)PLAIN 5)GAS 6)REUSE
Note: Special Lettering Available

Contact Tyler Union for

Setup Charge

Std=Standard Weight

41

6855 SERIES
CAST IRON TWO-PIECE VALVE BOXES

for 4" through 12" valves, 51/4" shaft, slip-type

SEPARATE UPCODES for VALVE BOX TOPS ONLY (Less Lids)



Box

TOP
Length

**(D-HD) UPCode
670610


Wt

144960
144960
144977
144977
144977
144984
144984
144984
144984

29
29
36
36
36
52
52
52
52

461-A (10T)
462-A (10T)
562-A (16T)
563-A (16T)
564-A (16T)
662-A (26T)
664-A (26T)
666-A (26T)
668-A (26T)
**NOTE: D=Domestic

**(ND-HD) UPCode
670610
Wt

502272
502272
502289
502289
502289
502296
502296
502296
502296

ND=Non-Domestic

**(ND-Std.) UPCode
670610

29
29
36
36
36
52
52
52
52

HD=Heavy Duty Weight

112211
112211
112228
112228
112228
112235
112235
112235
112235
Std=Standard Weight

Wt

15
15
25
25
25
38
38
38
38

EXTENSIONS

Item/Description

Height **(D-HD) UPCode **(ND-Std.) UPCode


Increase
670610
Wt
670610
Wt

#58-A Slip-Type 6 to 14
#59-A Slip-Type 6 to 18
#60-A Slip-Type 6 to 24

145233 29
145240 30
145066 36

136637
136644
112198

26
28
37

60-A Extension

58-A and 59-A Extension

SEPARATE UPCODES for VALVE BOX BOTTOMS ONLY



Box

Bottom **(D-HD) UPCode


Length
670610

**(ND-HD) UPCode

**(ND-Std.) UPCode

Wt

670610

Wt

670610

Wt

461-A
462-A
562-A
563-A
564-A
662-A
664-A
666-A
668-A

(15B)
(24B)
(24B)
(30B)
(36B)
(30B)
(36B)
(24B)
(36B)
(60B)

26
36
36
45
47
45
47
36
47
---

502302
502319
502319
502333
502340
502333
502340
*502319
*502240
---

26
36
36
45
47
45
47
36
47
---

112051
112068
112068
112075
112082
112075
112082
*112068
*112082
458302

20
30
30
39
43
39
43
30
43
75

145073
145080
145080
145127
145097
145127
145097
*145080
*145097
---

**NOTE: D=Domestic ND=Non-Domestic

HD=Heavy Duty Weight

Std=Standard Weight

*NOTE: Whe installing thes extensions a 6850 screw type bottom is required

42

6860 SERIES
CAST IRON THREE-PIECE VALVE BOXES

for 3" through 20" valves, 51/4" shaft, screw-type


***(Base required, order separately)

TYLER UNION valve boxes are available either pre-assembled or as


individual tops and bottoms. For assembled boxes, The UPC codes
shown represent a combination of one top and one bottom in the
sizes shown. For unassembled boxes, the UPC code represents only
a top or a bottom, not a complete box. Therefore, unassembled
boxes require ordering tops and bottoms separately.
**NOTE: Domestic Valve Boxes available in Heavy Duty Only

Non-Domestic available in Standard or Heavy Duty

Base Illustrated
For Position Only...
Not Furnished.
Box Assembled
(Less Lid)

Box (Components)

AA (10T + 12B)
A (16T + 18B)
B (16T + 24B)
C (16T + 30B)
CC (16T + 36B)
D (26T + 30B)
DD (26T + 36B)
E (16T+24B+60 Ext)
F (26T+24B+60 Ext)
G (26T+36B+60 Ext)

Extension *(D-HD)UPCode *(ND-HD)UPCode


Height
670610
670610
Wt

27-37
33-42
39-49
45-54
51-60
45-66
51-72
63-72
63-84
74-94

145912
145929
145936
145943
145950
145967
145974
145981
145998
146001

----
42
----
65
----
69
----
73
----
75
502357 88
502364 90
----
105
----
120
502371 126

*(ND-Std.)UPCode
670610
Wt

136668 29
136651 38
136675 51
136682 55
136699 59
136811 71
136828 75
136835 80
136842 96
136859 104

Lids marked WATER will ship


unless otherwise specified:
Also available 5" Drop Lids"
1)WATER OMA 2)SEWER 3)MWW
4)PLAIN 5)GAS 6)REUSE
Note: Special Lettering Available

Contact Tyler Union for

Setup Charge

*NOTE: D=Domestic ND=Non-Domestic HD=Heavy Duty Weight Std=Standard Weight


***NOTE: Base Selection Guide (#4 Base for 6 valves or less) (#6 Base for 12 valves or less) (#160 Base for 24 valves or less)

43

6860 SERIES
CAST IRON THREE-PIECE VALVE BOXES

for 3" through 20" valves, 51/4" shaft, screw-type


(Base required, order separately)
SEPARATE UPCODES for VALVE BOX TOPS ONLY (Less Lids)

Box

TOP
Length

**(D-HD) UPCode
670610


Wt

AA
A
B
C
CC
D
DD
E
F
G

(10T)
(10T)
(16T)
(16T)
(16T)
(26T)
(26T)
(16T)
(26T)
(26T)

144939
144939
144946
144946
144946
144953
144953
144946
144953
144953

23
23
36
36
36
51
51
36
51
51

**(ND-HD) UPCode
670610
Wt

502142
502142
502159
502159
502159
502166
502166
502159
502166
502166

**(ND-Std.) UPCode
670610

Wt

15
15
22
22
22
38
38
22
38
38
**NOTE: D=Domestic ND=Non-Domestic HD=Heavy Duty Weight .=Standard Weight

60 Extension

58 and 59
Extension

23
23
36
36
36
52
52
36
52
52

#4 Base

112402
112402
112419
112419
112419
112426
112426
112419
112426
112426

#6 Base
(Standard)

UPC
670610

BASES

eight
Increase

Wt

Item/Description

14
18
24
24
24

29
30
37
29
36

#4, 11 Wide
#6, 14 Wide
#160, 20 Wide

#58 Screw-Type 145141


#59 Screw-Type 145158
#60 Screw-Type 145059
#60 Screw-Type *112389
#60 Screw-Type * Call
*Non-Domestic

#160 Base

EXTENSIONS

Item/Description

*(D-HD)UPCode *(ND)UPCode
670610
670610

145653
145660
145684

----
----
----


Wt

34
45
68

*(ND-Std)UPCode
670610
Wt

381532
381525
256861

*D=Domestic ND=Non-Domestic HD=Heavy Duty Weight Std.=Standard Weight

SEPARATE UPCODES for VALVE BOX BOTTOMS ONLY



Box

Bottom **(D-HD) UPCode


Length
670610

**(ND-HD) UPCode

**(ND-Std.) UPCode

Wt

670610

Wt

670610

Wt

AA
A
B
C
CC
D
DD
E
F
G

(12B)
(18B)
(24B)
(30B)
(36B)
(30B)
(36B)
(24B)
(24B)
(36B)
(48B)
(60B)

19
29
33
37
39
37
39
33
33
39
---
---

---
505594
502388
502395
502401
502395
502401
502388
502388
502401
---
---

---
29
33
37
39
37
39
33
33
39
---
---

250524
250517
136958
136613
136620
136613
136620
136958
136958
136620
452713
452720

14
25
29
33
35
33
35
29
29
35
65
91

**NOTE: D=Domestic

145134
145141
145158
145165
145172
145165
145172
145158
145158
145172
---
---

ND=Non-Domestic

22
36
55

HD=Heavy Duty Weight

Std=Standard Weight

44

CAST IRON - STANDARD, SPECIAL


DROP, AND LOCK LIDS

5" MWW DROP LID


*(D-HD)UPCode *(ND-HD)UPCode
670610
670610
Wt.
145370

136880

12

*D=Domestic ND=Non-Domestic
HD=Heavy Duty Weight

Drop Lid

Lock Lid

RECLAIMED WATER LID



*(D-HD)UPCode
670610

458892

NOTE: Square Valve Box Tops for this


Lid will be available in 2012. Call Tyler
Union for information.
*D=Domestic HD=Heavy Duty Weight

5" OMA DROP LID**


*(D-HD)UPCode *(ND-HD)UPCode
Special
670610
670610
Markings
145301

136927

Wt.

**WATER OMA 12

*D=Domestic ND=Non-Domestic HD=Heavy Duty wt.


**OMA marking is inside lid.

WRENCH
Fits Standard Waterworks
Pentagon Head 27/32" Brass
Screws
UPCode
670610

144908

1 1/8" Lid

Ship
Code

Description

Wrench

Wt

0.5

LIDS (WATER)

*(D-HDUP)Code
Item/Description
670610

*(ND-Std)UPCode

Wt
670610
Wt

5 Drop Lid
5 Lock Lid
1 Lid**

12
11
11

145325
145462
145509

136910
136866
112532

9
11
9

*(ND-HD)UPCode
670610
Wt

---
---
---

-------

(Use with 1 Riser Only)


*NOTE: D=Domestic ND=Non-Domestic HD=Heavy Duty Weight Std=Standard Weight

5" DROP LID W/SPECIAL MARKINGS**


*(D-HD)UPCode *(ND-Std)UPCode

Special

670610

Wt.

Mark

145332
145349
145356
458975

12
12
12
12

670610 Wt.

136873
136903
136897
---

9
9
9
---

GAS
SEWER
PLAIN
REUSE

**Lids marked with WATER will be


shipped unless otherwise specified.

45

CAST IRON - FIXED AND


ADJUSTABLE RISERS PLUS
SPECIALTY VALVE BOX TOPS

5" x 1 " Riser


(Requires 1 " Riser Lid)

5" x 2" Riser


(Uses Standard 5"
Drop Lid)

IRON RISERS

#69 SCREW TYPE ADJUSTABLE RISER


FOR 6850/60 SERIES
(Uses Standard Drop Lid)
*(D-HD)UPCode *(ND-HD)UPCode
670610
670610

148197

112396

Height
Increase


Item/Description

Weight

2" - 9"

*(D-HD)UPCode. *(ND-HD)UPCode
Height
670610
670610
Increase

29

5 x 1 Slip-In*
5 x 2 Slip-In

145554
145547

112549
112556

Wt

1 "
2"

8
14

*Use with 1 " Lid Only.


*D=Domestic ND=Non-Domestic HD=Heavy Duty

*D=Domestic ND=Non-Domestic HD=Heavy Duty

Specialty Iron Valve Box Tops - Call for Submittal / Product Drawing
*D-UPCode

376774

**ND-UPCode

502883

**ND-UPCode

502890

#69-A SLIP TYPE ADJUSTABLE RISER


FOR 6855 SERIES
(Uses Standard Drop Lid)
*(D-HD)UPCode *(ND-HD)UPCode
670610
670610

148241

112204

Height
Increase

2" - 12"

*D=Domestic ND=Non-Domestic HD=Heavy Duty

Wt

29

Description

Weight

Description

Weight

Description

Weight

7126-26T Slip Type Special with


Top Flange
See 29U Submittal for dimensions
Lid Type: Uses Standard 5-1/4" Drop
910-18T Slip Type Special with
Top Flange
Body: 7.0" Inside Diameter
7.5" Outside Diameter
Top Flange: 12" Outside Diameter
Flange 3/8" Thick
Lid: Call for Information

49

37

940-18T Slip Type Special with


Bottom Flange
Body: 6.125" Inside Diameter
6.50" Outside Diameter
Bottom Flange: 9.25" Outside Diameter
Flange 7/16" Thick
Lid: Call for Information

Note: *D = Domestic

35

**ND = Non-Domestic

46

METER COVERS, TOUCH-READER (TR)


RINGS & LIDS

6150 & 6150TR METER COVERS,


CAST IRON
Description

18-in. 6150 Series


20-in. 6150

6150 Meter Box Cover

UPCode
670610

Ship
Code

148449
148456
148647
148494
148593
148500
148463
148470
148630

S
S
S
S
S
S
S
S
S

8
9

18
20

20
22

Description

Weight

6150-18 Ring & Lid B/L*


6150-18 Ring & Lid B/S*
6150-18 Ring Only
6150-18/20 Lid With Lock B/L*
6150-L-18/20 Lid Less Lock
6150-18/20 Lid With Lock B/S*
6150-20 Ring & Lid B/L*
6150-20 Ring & Lid B/S*
6150-R-20 Ring Only

39
39
27
13
14
13
41
41
29

*B/L = Large
Bolts (1-1/32"); *B/S = Small
Bolts (27/32" Standard)
NOTE: The B/L & B/S pentagon head screws use the same worm or locking gear.

6150TR (TOUCH-READER) METER COVERS CAST IRON


UPCode
670610

Ship
Code

148531
148524
148579
148562
148586
148555
148548

S
S
S
S
S
S
S

Description

Weight

6150-18 TR Ring & Lid B/L


6150-18 TR Ring & Lid B/S*
6150-18/20 TR Lid With Lock B/L*
6150-18/20 TR Lid With Lock B/S*
6150-18/20 TR Lid Less Lock
6150-20 TR Ring & Lid B/L*
6150-20 TR Ring & Lid B/S*

39
39
13
13
12
41
41

*B/L = Large Head Bolts (1-1/32"); B/S = Small Head Bolts (27/32")
NOTE: 6150TR - Same dimensions as 6150, plus a 1-27/32" access hole in lid.
NOTE: The B/L & B/S pentagon head screws use the same worm or locking gear.

6150TR Meter Cover


6200 METER COVER, CAST IRON
UPCode
670610

Ship
Code

148708
148760
148739
148722

S
S
S
S

Description

Weight

6200 Ring & Lid Less Lock


6200-R Ring Only
6200-L Lid Less Lock
6200-L Lid With Lock

28
18
13
11

WRENCH
Fits Standard Waterworks
Small Pentagon Head 27/32" Brass Screws

6200 Meter Cover


256772_utility catalog.pdf 47

UPCode
670610

Ship
Code

Description

Weight

144908

Wrench

0.5

47

12/15/08 8:24:30 AM

assembly instructions

ADAPTER FLANGE
Wall Thickness Note:
Recommended for ductile
iron pipe Class 53 thru
Class 56.

FM APPROVED
1. Place adapter flange and MJ gasket over the plain end of the
pipe with the small side of the MJ gasket facing the flange
side of the adapter flange.
2. Place the pipe end against flange to be joined and slip the
MJ gasket into position against the flange. Make sure the
gasket is evenly seated against the flange.
3. Slide adapter flange into position against the small (tapered) side of the MJ gasket and align the bolt holes.
Insert the bolts and finger tighten the nuts to maintain position and alignment.
4. Snug up all nuts evenly. Alternating @ 180, tighten the nuts to a torque of: 3" - 60 foot pounds; 4" thru 12"
- 90 foot pounds.
5. Snug up all set screws evenly around the pipe. Tighten the Torque Head Set Screws evenly, alternating at 180
degrees.
NOTE: THE TORQUE HEAD TOP WILL BREAK OFF AT THE RECOMMENDED SETTING OF 80-90 FT. LBS.
MAXIMUM DEFLECTION OF JOINT ( 2)

*SET-SCREW RETAINER GLAND


Pipe Wall Thickness: Sizes 3"-12" are recommended for ductile iron pipe class 50 thru 56. Sizes 14" thru 24" are recommended for ductile iron pipe class 53 thru 56.

1. Wash bell and plain end with soapy water, then slip
gland and gasket over plain end with the small side of
the gasket and ring side of
gland facing the bell.
2. Slip plain end into bell. Brush soapy water on gasket.
This lubricates the gasket and allows it to slip easily
into place. Push gasket into bell making sure it is
evenly in the bell gasket landing.
3. Slide the gland into position against the back of the
gasket. Align bolt holes, insert T-bolts and tighten nuts
to finger tight.
4. Snug up all T-bolt nuts evenly. Alternating at 180,
tighten the T-bolt nuts to a torque of:
3" - 60 foot pounds 4" thru 24" - 90 foot pounds.
5. Snug up all set screws evenly. Using a torque wrench, tighten the set screws alternating at 180 to the
recommended torque value of 75 foot pounds. If required double check set screws immediately.
Maximum recommended deflection of joints:

3" thru 12"-2; 14" thru 30" - 1
*Note: Not recommended for use on plain end fittings

256772_utility catalog.pdf 50

48

12/15/08 8:24:31 AM

MAKING OFFSETS ON THE JOB

Using Two BendsOffset in Inches


Nominal
Diameter
Inches

3
4
6
8
10
12
14
16
18
24
30



90

14.00
15.00
18.00
20.00
24.00
26.00
31.50
33.50
38.00
41.50
N/A

Nominal
Diameter
Inches

3
4
6
8
10
12
14
16
18
20
24
30



90

19.60
21.50
24.50
26.60
30.50
32.50
36.50
38.50
41.50
44.50
52.50
58.50

Nominal
Diameter
Inches

3
4
6
8
10
12
14
16
18
20
24
30

90

11.00
13.00
16.00
18.00
22.00
24.00
28.00
30.00
33.00
36.00
44.00
50.00

256772_utility catalog.pdf 51

153 -A21.53
C
Mechanical Joint
45

22

6.36
7.07
8.48
9.19
10.61
12.02
13.08
13.79
14.14
16.40
N/A

3.06
3.31
3.89
4.09
4.48
4.87
5.88
5.92
8.92
9.76
N/A

110 -A21.10
C
Mechanical Joint
45

22

10.25
11.69
13.06
13.76
15.19
16.62
16.62
17.32
18.03
19.45
21.57
27.23

5.56
6.31
7.08
7.50
8.25
9.00
8.99
9.38
9.76
10.52
11.67
14.73

C110 -A21.10
Standard Flange
45
22

4.24
5.66
7.07
7.78
9.19
10.61
10.61
11.31
12.02
13.44
15.56
21.22

2.30
3.06
3.83
4.21
4.98
5.74
6.74
6.12
6.51
7.27
8.42
11.48

11

1.46
1.58
1.68
1.77
1.88
1.97
2.47
2.48
2.54
4.97
N/A

Flanged Joint*

Mechanical Joint

No allowance is made in
offset figures for gasket thickness.

DETERMINING LENGTH OF PIPE IN OFFSETS

11

2.63
3.02
3.41
3.61
4.00
4.39
4.39
4.58
4.78
5.17
5.75
7.32

Mechanical Joint


Angle

45
22
11

D
Equals

T x 1.414
T x 2.613
T x 5.126

R
Equals

T x 1.000
T x 2.414
T x 5.027

L
Equals

D-2A
D-2A
D-2A

Cut the Pipe somewhat shorter to allow for clearance in the joints.

11

Long
Radius
90

1.17
1.56
1.95
2.15
2.54
2.93
2.93
3.12
3.32
3.71
4.29
5.85

15.50
18.00
23.00
28.00
33.00
38.00
43.00
48.00
53.00
58.00
68.00
N/A

Example:
A 14-inch Mechanical Joint line is to be offset
12 feet on an angle of 45-degrees using two
C110 full-body Mechanical Joint bends. What
is the laying length (L) of pipe required to make
the connection between the two bends?
Solution:
D = 12'0" x 1.414 =16.968'
R = 12' x 1.000 = 12.000'
A = 7.5" or .625'
L = 16.968' - 1.250 = 15.718' or
approximately 15' 8".

49

12/15/08 8:24:32 AM

PIPE O.D.'S AND FLANGE DATA


Because many items listed are not made by Tyler
, we cannot be
certain that all data is current or accurate. Please check with the product
manufacturer for their most recent information.
PIPE O.D. CHART

GRAY/DI IRON
CAST IRON/DWV
ASBESTOS - CEMENT
CLASSES
O.D.
SV
NH
XH
CLASS MACHINED ROUGH

PIT SPUN
END O.D. BARREL O.D.




PIPE
SIZE

1-1/2"
2"
2-1/2"


3"




4"


5"




6"




8"




10"




12"




14"


15"


16"


18"


20"


24"




A
B,C,D

A
B,C,D



A
B,C,D
E,F
A,B
C,D
E,F
A,B
C,D
E,F
A,B
C,D
E,F
A,B
C,D
E,F

A,B
C,D
E,F
A,B
C,D
A,B
C,D
A,B
C,D





50-350

50-350




50-350


50-300
350

50-200
250-350

50-200
250-350

50-100
150-300


50-100
150-300

50-100
150-250
50-100
50-250
50-100
150-250

Size

2
2
3
3
4
5
6
8
10
12
14
16
18
20
24

256772_utility catalog.pdf 52


2.50

3.80
3.96

4.80
5.00



6.90
7.10
7.22
9.05
9.30
9.42
11.10
11.40
11.60
13.20
13.50
13.76
15.30
15.65
16.98

17.40
17.80
18.16
19.50
19.92
21.60
22.06
25.80
26.32


2.30.09

3.30.09


4.30.09


5.30.09

6.30.09


8.38.13


10.50.13


12.5019





15.88.19








1.90.06
2.35.09

3.35.09


4.38+.09
-.05

5.30+.09
-.05
6.30+.09
-.05

8.38+.13
-.09

10.56.09


12.50.09





15.83.09









2.38

3.50


4.50


5.50
6.50


8.62


10.75


12.75





15.88








125 LB. Flanges And Bolts


Diam of
Bolt
Number of Diam Of
Flange
Circle
Bolts
Bolts
6
4
4

7
5
4

7
6
4

8
7
8

9
7
8

10
8
8

11
9
8

13
11
8

16
14
12

19
17
12

21
18
12
1
23
21
16
1
25
22
16
1
27
25
20
1
32
29
20
1

Length
Of Bolts
2
2
2
2
2
3
3
3
3
3
4
4
4
5
5

PVC
PVC
PVC
C-900 C-905 STEEL O.D
DI O.D. DI O.D. SCH. PIPE

MIN. - MAX.





100
150
200
100
150
200




3.74
3.84
3.84
4.64
4.81
4.81




4.00
4.10
4.29
4.79-5.14
4.97-5.27
5.22-5.57

100
150
200
100
150
200
100
150
200
100
150
200
100
150
200

6.91
6.91
6.91
9.11
9.11
9.11
11.24
11.66
11.66
13.44
13.92
13.92
15.07
16.22
16.22

7.05-7.40
7.07-7.37
7.26-7.56
9.22-9.57
9.27-9.57
9.39-9.74
11.42-11.77
11.82-12.12
11.77-12.12
13.69-14.04
14.08-14.38
14.03-14.38
15.40-15.80
16.38-16.73
16.48-16.88

100
150
200
100
150
100
150
100
150

17.14
18.46
18.46
19.90
20.94
22.12
23.28
26.48
27.96

17.54-17.94
18.62-18.97
18.79-19.19
20.44
21.20
22.50
23.54
27.17
28.22

Pipe
Sizes
2
2
3
3
4
5
6
8
10
12
14
16
18
20
24

STEEL
TYPE O.D.

DR 41
32.5
25.18

40, 80, 120


C 905 IPS
DIA. 14 - 24


2.50

1.90
2.38
2.88
3.50

STD.
STD.
STD.
STD.

1.90
2.38
2.88
3.50

4.80

4.50

O.D.
STD.

4.00
4.50

5.56

STD.

5.56

6.90

6.63

O.D.
STD.

6.00
6.63

9.05

8.63

O.D.
STD.

8.00
8.63

11.10

10.75.

O.D.
STD.

10.00
10.75

13.20

12.75

O.D.
STD.

12.00
12.75

15.30

O.D.

14.00

17.40

O.D.

16.00

19.50

STD.

18.00

21.60

STD.

20.00

25.80

STD.

24.00

250 L.B. Flanges And Bolts


Diam of Diam of Number of Diam of
Flanges Wt Circle
Bolts
Bolts
6
5
8

7
5
8

8
6
8

9
7
8

10
7
8

11
9
8

12
10
12

15
13
12

17
15
16
1
20
17
16
1
23
20
20
1
25
22
20
1
28
24
24
1
30
27
24
1
36
32
24
1

Length
of Bolts
2
3
3
3
3
3
3
4
5
5
5
6
6
6
7
50

12/15/08 8:24:32 AM

FREQUENTLY ASKED QUESTIONS

Question: From what compound is the standard MJ gasket made and what is the highest water
temperature it will withstand? Are the TYTON
gaskets made from the same compound?
Answer: The standard MJ
gasket is made of vulcanized styrene butadiene rubber (SBR)
in accordance with ANSI/AWWA C111/A21.11. The recommended temperature range for SBR
gaskets is from 20F to 180F. SBR gaskets are suitable for water and wastewater, most moderate
chemicals, wet or dry organic acids, alcohols, ketones, *chloramines, and aldehydes.
SBR GASKETS ARE NOT
*Note: Rated for Chloramine concentrations of less than 5 parts per million.
NOTE: Review the 31U Submittal on pages 71 and 72 of this catalog for additional gasket information

uestion: Does Tyler Union Waterworks offer any other gaskets that will withstand temperatures
greater than180 F or for special service applications?
Answer: Yes! Tyler Union offers
other special services gaskets for MJ connections only.
Identification, temperature range and applications are listed below:
EPDM (Ethylene Propylene) - Minus 10F to 250F Ideal for water and wastewater, ozone and strong
oxidizing chemicals. May be used on steam within given temperature range and on hot air
without hydrocarbons. OT RECOMMENDED FOR HYDROCARBON SERVICE.

NEOPRENE (CR) - Minus 10F to 200F Recommended for moderate chemicals and acids, oil fats,
many solvents and air with hydrocarbons. Will not support combustion.
Nitrile (NBR) (Buna - N) (Hycar) - Minus 40F to 250F Ideally suited for gasoline, petroleum
products, hydrocarbons, water and mineral and vegetable oils.
FKM (Fluoroelastomer) Minus 10F to 425F Ideal for hydrocarbons, acids, vegetable oils, and petrolium
u
estion: According to AWWA, how much torque should be applied to Mechanical Joint T-bolts?
Q
Answer: The recommended torque ranges, as stated in ANSI/AWWA C600 are:
Joint Size
in.
(mm)

3
(76)
4-24
(102-610)
30-36
(762-914)
Q
42-48 (1067-1219)

Range of Torque
ft/lb

N/m
45-60
(61-81)
75-90
(102-122)
100-120
(136-163)
120-150
(163-203)

uestion: What type of Mechanical Joint T-bolt does Tyler Union Waterworks furnish?
supplies High-strength, Low-Alloy Steel T-bolts, in compliance with ANSI/AWWA
Answer: Tyler
C111/A21.11. Contents of standard MJ Accessory packs comply with ANSI/AWWA C111/A21.11.
Anti-Rotation T-bolts, Blue Fluoropolymer coated T-bolts and tainless teel (AISI 316 and AISI 304)
T-bolts are also available for special applications on request.
For applications requiring specific weights or laying lengths of our fittings, contact Tyler Union

256772_utility catalog.pdf 53

51

12/15/08 8:24:32 AM

FREQUENTLY ASKED QUESTIONS

Question:

material are the Standard T-bolts, Anti-Rotation and

T-bolts made of?

Answer: The Standard T-bolts and Anti-Rotation T-bolts and Nuts are manufactured from
Corrosion Resistent, High-Strength, Low-Alloy Weathering Steel in accordance with ANSI/AWWA C111
(Current Revision). Blue Fluorokote #1, T-bolts and Nuts are manufactured from the same high quality
material as the standard T-bolts/Nuts but
a
fluoropolymer resin that is baked on and was
developed
highly corrosive soil conditions.
low alloy T-bolts and
Fluorokote #1 Green SS304 and Red SS316 comply with ANSI/AWWA C111/A21.11 (Current Revision).
Question: How is the torque range for flanged fittings and gaskets determined?
Answer: The required torque for flanged fittings and gaskets is not addressed in the ANSI/AWWA
C600 Standard. Generally, this torque range is determined by the flange gasket manufacturer
due to the various
gaskets, bolt patterns and fitting flange diameters available.
Question: What purpose does the cement mortar lining serve?
Answer: Cement mortar lining serves to prevent tuberculation

flow characteristics.

Question: What function does the seal coating of fittings serve?


Answer:

of
lining with improved strength. Tyler
applies a seal
proved for use in potable water systems and it will cover the entire fitting unless specified otherwise during
order placement. The exterior is coated for aesthetic and to aid in retarding corrosion prior to installation.
Question: Are the fittings furnished by Tyler

UL/FM approved?

Answer: yler Union ductile iron ANSI/AWWA C110/A21.10


Watermain ittings
are UL listed for Fire Main Equipment and ANSI/AWWA C153/A21.53
for 3"-12" are UL and 3"-10" FM listed for Fire Main Equipment. (UL Listing #EX2111)(Union-Tite 4" to 12")
Question: Does Tyler

offer fittings with any coatings other than an asphaltic seal coat?

Answer: Yes. For Flanged Full Body


and Compact (C153) fittings, Tyler
offers an exterior
prime coat of Tnemec N140-1211 Pota-Pox Plus that is NSF-61 approved for potable water systems and is
accompanied by a cement mortar/seal coated lining. Tyler
also offers double cement lining upon
request. Bare castings are available upon request. Additionally, Tyler Union offers a full line of Protective
Fusion Bonded Epoxy (FBE) coated and lined fittings for drinking water service applications. Other specialty
coatings and linings may be available upon request; contact your Tyler Union Inside Sales representative
for more information. Tyler Union's FBE fittings are red oxide color plus the coating and lining are supplied
standard with 6 to 8 mil average thickness. Our FBE meets the requirements of ANSI/AWWA C116/A21.16.
For additional FBE information, see the 20U submittal on pages 56 and 57.
Question: Does Tyler

offer

coating for wastewater

Answer:

256772_utility catalog.pdf 54

52

12/15/08 8:24:32 AM

27U-BOLTS AND NUTS FOR MECHANICAL JOINTS


*Bolts and Nuts meet ANSI/AWWA C111/A21.11
*ASTM A242 High Strength Low Alloy Steel (Coated or Uncoated)
*ANSI 304 or 316 AISI Stainless Steel (Coated Green or Red)
*Flouropolymer is Fluorokote #1 (Blue for Low Alloy Steel)

NOTES:
1. Dimension B is unthreaded shank.
2. Draft, when required to be
6 degree maximum, may
be deducted from bolt head
dimensions, and radius
(B/2) may be changed to
suit draft.
3. Gates, if required, may
protrude a maximum of
1/8 inch above the top of
the bolt head.
4. Chamfer is optional if
threads are rolled.

T-Head Low Alloy Weathering and AISI Stainless Steel Fasteners


Dimensions in Inches



Size
Inches

A
0.05

B
+0.030
-0.074

C
+0.25
-0.06

Threads
per Inch

E

J
+0.15
-0.03

R
Max.

x 3
1.50
0.625
3.0
2.00
11
0.625 +or -.04
1.062-.04
0.625
0.312
x 3.5
1.75
0.750
3.5
2.50
10
0.750 +or -.06
1.250 -.06
0.750
0.375
x 4
1.75
0.750
4.0
3.00
10
0.750 +or -.06
1.250 -.06
0.750
0.375
x 4.5
1.75
0.750
4.5
3.00
10
0.750 +or -.06
1.250 -.06
0.750
0.375
x 5
1.75
0.750
5.0
3.00
10
0.750 +or -.06
1.250 -.06
0.750
0.375
1 x 6
1.75
1.000
6.0
3.00
8
1.000 +or -.08
1.625 -.08
1.000
0.500
1 x 7.5
2.25
1.000
7.5
4.50
8
1.000 +or -.08
1.625 -.08
1.000
0.625
1-1/4 x 6.5 2.50
1.250
6.5
3.50
7
1.250 +or -.08
2.000 -.08
1.250
0.750
1-1/4 x 8.5 2.50
1.250
8.5
4.00
7
1.250 +or -.08
2.000 -.08
1.250
0.750

The tolerance for cast iron bolts is +or-0.03". If threads are rolled, the body diameter may be reduced to the
approximate pitch diameter of the thread.
Tolerance:
+3, - 0 threads
Number of threads per inch - course-thread series (ANSI/ASME B1.1), Class 2A,
.
course-threads series (ANSI.ASME B1.1), Class 2A, external fit UNC2A and Class 2B, UNC2B (ANSI/ASME B1.2

Excavation

dimensions - MJ 4" through 12" Tapping Sleeves for Ductile Pipe


53

256772_utility catalog.pdf 55

12/15/08 8:24:33 AM

MJ FIELD LOK

PROVEN JOINT
RESTRAINT TECHNOLOGY

A RESTRAINT REVOLUTION. Spend less time and money - restraining mechancial joint fittings
with the new MJ FIELD LOK Gasket.

NO LEARNING CURVE
FOR DUCTILE IRON
AND PVC PIPE
CURRENTLY AVAILABLE:
Ductile Iron 4" - 24"

PVC 4" - 12"

UL Listed and FM approved.

MJ FIELD LOK Gasket Series DI

Proven joint restraint technology.

Can be used on any Pressure Class or Special Thickness


Class Ductile Iron pipe up to 350 psi. Not recommended
for use with Plain end Ductile iron fittings.

No learning curve - installs just like a standard


mechanical joint gasket and gland.
No more need for time-consuming thrust blocks or
heavy lug-type restraints.
No loose wedges or torque-off control nuts to get
lost or broken.
Can be disassembled just like a standard mechanical joint.
Suitable for potable water and wastewater applications.
The state-of-the-art MJ FIELD LOKTM Gland is
designed for maximum strength and easy product
identification.
MJ FIELD LOK Gaskets are provided as part of a kit
that also includes the MJ FIELD LOKTM Gland, nuts
and bolts.

Stainless steel locking segments provide proven joint


restraint technology.

MJ FIELD LOK Gasket Series PV


Can be used on any thickness class of AWWA C900 and


C909 pipe.

Pressure rated at a 2:1 safety factor, based on the pressure rating of the pipe on which it is installed.
Ductile iron locking ring provides proven joint restraint
technology.

MJ FIELD LOK Gland


Highly engineered to provide the strength and
rigidity necessary for restrained joint applications.
Installs just like a standard mechanical joint gland.
All ductile iron components are manufactured to ASTM
A536 Grade 70-50-05.

MJ FIELD LOK Gasket Series PV

MJ FIELD LOK Gland


MJ FIELD LOK Gasket Series DI

256772_utility catalog.pdf 57

54

12/15/08 8:24:33 AM

Application Notes:
1. MJ FIELD LOK Gaskets are
designed to seal and restrain a
centrifugally cast ductile iron or PVC
pipe spigot in either a ductile iron
pipe or a ductile iron fitting bell.

4. MJ FIELD LOK Gaskets require 90 ft-lb


of bolt torque for 4" - 8" gaskets, and
120 ft-lb of bolt torque for 10" - 12"
inch gaskets. Most common 1/2" drive
air powered impact wrenches are
capable of applying these torques.

2. MJ FIELD LOK Gaskets are


available to fit mechanical joints
conforming to AWWA C110 or
AWWA C153 in 4" - 24" sizes.

5. MJ FIELD LOK Gaskets are


suitable for either potable water or
wastewater applications.

3. If ductile iron pipe with a lower


pressure rating is used, then the
lower pressure rating will apply to
the MJ FIELD LOK Gasket also.

6. MJ FIELD LOK Gaskets are


NSF approved, UL Listed and
FM Approved.

7. MJ FIELD LOK Gasket Series DI


products are not recommended for
use with cast iron pipe, plastic pipe,
oversize pipe, metric pipe,
DI fittings, or as a transition gasket.
8. MJ FIELD LOK Gasket Series PV
products are not recommended for
use with cast iron pipe, ductile iron
pipe, oversize pipe, metric pipe, or
for use as a transition gasket.
9. MJ FIELD LOK Gaskets are warranted
only when used with MJ FIELD LOKTM
Gland.

MJ FIELD LOK Gasket Series DI



SIZE
PIPE
ORDER
NO. OF
PRESSURE
(Inches)
OD
NUMBER SEGMENTS
RATING

4
6
8
10
12
14
16
18
20
24

4.80
6.90
9.05
11.10
13.20
15.30
17.40
19.50
21.60
25.80

DI04
DI06
DI08
DI10
DI12
DI14
DI16
DI18
DI20
DI24

3
4
6
9
13
18
24
30
36
52

APPROX.
KIT
WEIGHT

350
350
350
350
350
350
350
250
250
250

7.3
10.9
13.5
18.5
19.7
26.9
31.8
49.8
59.7
81.3

MJ FIELD LOK Gasket Series PV



SIZE
PIPE
(Inches)
OD

4
6
8
10
12

4.80
6.90
9.05
11.10
13.20

PRESSURE PRESSURE
ORDER
RATING
RATING
NUMBER
DR-18
DR-14
(psi)
(psi)

PV04
PV06
PV08
PV10
PV12

150
150
150
150
150

APPROX.
KIT
WEIGHT

200
200
200
200
200

MJ FIELD LOKTM Gland

7.8
11.8
14.8
20.1
21.6

MJ FIELD LOK Gland (See illustration at right)



DIMENSION
SIZE WEIGHT
A
B
C
D
E
(Inches) (pounds) (Outside Dim) (Bolt Hole) (Inside Dia.) (OD Lip) (Gland Height)

4
6
8
10
12
14
16
18
20
24

3.3
5.0
7.2
10.2
11.0
17.2
25.0
38.0
46.0
64.0

8.88
10.87
13.13
15.38
17.63
20.13
22.38
24.75
27.00
31.50

Suggested Specifications:

7.50
9.50
11.75
14.00
16.25
18.75
21.00
23.25
25.50
30.00

4.90
7.00
9.15
11.20
13.30
15.44
17.54
19.64
21.74
25.94

5.92
8.02
10.17
12.22
14.32
16.40
18.50
20.60
22.70
26.90

1.75
2.00
2.25
2.25
2.25
2.51
2.75
3.14
3.20
3.57

Joint restraint for mechanical joint pipe and fittings shall be the MJ FIELD LOK Gasket. The restraint system shall be completely integral to the
gasket, requiring only standard mechanical joint assembly techniques. The restraining system for ductile iron shall be pressure rated to 350
psi in sizes up to and including 16"; 18", 20" and 24" are rated for 250 psi. The restraining system for PVC shall be rated at a 2:1 safety factor
for the pipe on which it is installed. The restraining system shall be rated in accordance with the performance requirements of ANSI/AWWA
C111/A21.11 Rubber Gasket Joints for Ductile-Iron Pressure Pipe and Fittings. Not recommended for use on Ductile iron Plain end fittings.

256772_utility catalog.pdf 58

55

12/15/08 8:24:33 AM

SUBMITTAL: PROTECTIVE FUSION BONDED EPOXY (FBE)


(Current revisions for all noted Standards apply)
Tyler Union Waterworks standard applied coating thickness for protective fusion bonded epoxy (FBE) is 6 to 8
mil and our FBE is NSF61, NSF-372 and Annex G approved. Tyler Union Waterworks FBE water works fittings are coated
internally and externally in accordance with the applicable requirements of ANSI/AWWA C116/A21.16. Section 4.3.2 of
the ANSI/AWWA C116 standard provides that FBE mil thickness in the joint area shall not have a coating of less than 4
mil. Additionally, the standard advises it may be necessary to establish a limit for the maximum applied thickness in the
joint areas.
Tyler Union Waterworks upon request at time of order placement, can provide FBE fittings with increased mil
thickness. However, FBE thickness greater than 6 to 8 mil may interfere with the pipe to fitting fit and inhibit the sealing
for a leakproof joint. For these reasons, Tyler Union Waterworks does not provide warranty for FBE lined and coated
fittings with greater than 8 mil thickness in the joint area.
Tyler Union Waterworks FBE is tested and approved per Underwriters Laboratories UL262. Testing of FBE
involves immersing coated parts in four aqueous solutions at 158F and evaluate for blistering during 90 day continuous
exposure period. The solutions are distilled water, 2% sodium chloride in distilled water, distilled water with a pH
adjusted to 4.0 using potassium hydrogen phthalate, and distilled water with pH adjusted to 10.0 using sodium
carbonate. Tyler Union Waterworks FBE is also tested for blister resistance when immersed in acid, alkali, alcohol, and
hydrocarbons at room temperature over 90 days. Additional test data and recommended exposures for Tyler Union
Waterworks FBE is as provided in Tables 1 thru 3.
The ANSI/AWWA C116/A21.16 standard describes the use of protective fusion bonded epoxy coatings as being
utilized for the interior and exterior surfaces of ductile or gray iron fittings supplied for water systems. Section 1.1 of
the standard specifically provides that the standard does not cover instances where coatings are agreed upon by
purchaser and manufacturer for sewer or other special applications. Though not always recommended for use in
**Sewer systems; FBE coated and lined fittings may be used in sewer applications conveying materials conforming to
the properties as provided in Tables 2 and 3 on page 2.
TEST
Abrasion Resistance
Adhesion
Adhesion
Gloss, 60
Humidity Resistance
Impact
Pencil hardness
Salt Spray

METHOD
ASTM D4060
ASTM D3359 - Method A
ASTM D3359 - Method B
ASTM D523
ASTM D2247
ASTM D2794
ASTM D3363
ASTM B117

Water Resistance
Weather Resistance

AWWA C550
ASTM G154

TABLE #1
CONDITIONS
CS-17 wheels, 1000 cycles, 1 kg load
X-cut and tape
Crosshatch and tape
N/A
1000 hours at 100F
N/A
N/A
1000 hours
90 days immersion at 70C
UVA-340, cycle 4 hrs UV at 60C, 4
hrs condensation at 50C

Tyler Union Waterworks Call Centers


11910 CR 492 Tyler, Texas 75706 (800) 527-8478
th
1501 W 17 St. Anniston, Alabama 36201 (800) 226-7601
1001 El Camino Ave. Corona, California 92879 (866) 527-8471
www.tylerunion.com

RESULT
32 mg loss
5A
5B
70-85
No blisters or rusting
Pass 40 inch-lbs. direct
Pass 4H
No blisters or face rust,
no scoreline creepage
Pass
Chalks after 200 hours
exposure

56

SUBMITTAL: PROTECTIVE FUSION BONDED EPOXY (FBE)


(Current revisions for noted Standards apply)
TABLE #2
Immersion Environments with the following chemicals (ambient temperature)
Aliphatic Hydrocarbons
Fresh water
Calcium Chloride (10% solution)
Fuel Oil
Calcium Hydroxide (10% solution)
Hexane
Calcium Sulfate (saturated solution)
Kerosine
Calcium Carbonate (saturated solution)
Motor oil
Distilled water
Magnesium Sulfate (saturated solution)
Gasoline (unleaded)
Potassium Acetate (saturated solution)
Diesel Fuel
Soap solutions
Sodium Chloride (5% solution)
Sodium Nitrate (10% solution)
Sodium Hydroxide (5% solution)
Trisodium Phosphate (5% solution)
TABLE #3
Splash and Spillage Environments against the following chemicals
Aromatic Hydrocarbons
Butanol
Ethanol
Hydrochloric Acid (5% solution)
Isopropyl Alcohol
Methanol
Sulfuric Acid ( 5% solution)
Toluene
Xylene
*NOTE:
Due to the prescribed application methods of protective fusion bonded epoxy
and the combination of varying fitting diameters, recesses, raised lettering, tapping
bosses, and numerous radiused surfaces; the applied thickness of the FBE coating
or lining may vary 1 to 2 mils over the coated surfaces of a fitting.
**NOTE:
Final determination of the suitability of this product for your application shall be
determined by the end user .
Additional types of epoxy coatings are available upon request at time of order
placement. Please contact a Tyler Union Waterworks Customer Service representative
to discuss the additional coating and lining options that are available.

Tyler Union Waterworks Call Centers


11910 CR 492 Tyler, Texas 75706 (800) 527-8478
th
1501 W 17 St. Anniston, Alabama 36201 (800) 226-7601
1001 El Camino Ave. Corona, California 92879 (866) 527-8471
www.tylerunion.com

57

SUBMITTAL: CEMENT-MORTAR and ASPHALTIC MATERIAL


(Current revisions for the noted Standards apply)
Tyler Union Waterworks Type I-II cement lining and asphaltic coating and lining provided with our ANSI/AWWA C104 cement-mortar
lined ductile iron fittings are NSF-61, NSF-372 and Annex G approved. Tyler Union Waterworks lined and/or coated 2 inch through 64 inch fittings
are provided in accordance with and meet all the applicable terms and requirements of ANSI/AWWA C104/A21.4, ANSI/AWWA C110/A21.10,
ANSI/AWWA C111/A21.11, ANSI/AWWA C153/A21.53, ANSI/AWWA C151/A21.51, and ASTM C150.
The standard specified thicknesses for cement and asphaltic linings for ductile iron fittings 2 inch through 64 inch are as provided.
Unless specified otherwise upon order placement, all cement lined **fittings provided by Tyler Union Waterworks will be provided with an
asphaltic lining and coating and the minimum thickness cement lining as provided for by ANSI/AWWA C104.
Fitting Sizes

Minimum AWWA Cement *Double Cement


Minimum Asphaltic Typical Tyler Union
Lining Thickness
Lining Thickness
Thickness
Asphaltic Thickness
2 in. to 12 in. or 76 to 305 mm
1/16 or 1.6 mm
1/8 or 3.2 mm
1 mil
2 4 mil
14 in. to 24 in. or 356 to 610 mm
3/32 or 2.4 mm
3/16 or 4.8 mm
1 mil
2 4 mil
30 in. to 64 in. or 762 to 1600 mm
1/8 or 3.2 mm
1/4 or 6.4 mm
1 mil
2 4 mil
*NOTE: You must specify double cement lining upon order placement
**NOTE: Mechanical Joint Solid Sleeves, Caps, and Plugs are provided with asphaltic coating only per AWWA C110/C153 Section 4.4.3
The asphaltic coating and lining utilized on the inside of pipe and fittings is to aide in the proper curing of the cement mortar lining as
described in the ANSI/AWWA C104 standard, Section 4.10. The Asphaltic coating and lining utilized on the outside of pipe and fittings is for
cosmetic purposes and intended to provide some level of corrosion protection prior to being installed
The purpose of the cement lining on the inside of ductile iron water works fitting is to reduce the degree of tuberculation (buildup) or
corrosion on the fitting wall. Tuberculation or corrosion of the fitting wall is minimized in soft or acid water as the cement lining creates a high pH
at the fitting wall. Beginning in 1995, the asphaltic lining for the inside of fittings is no longer required by the AWWA but is recommended in
instances where the pH of the water is less than 6.0 or greater than 10.0.
Additional Applications and Ratings for Cement-Mortar and Asphaltic Materials:
Cement without asphaltic coating: Service to *212F max.
Cement with asphaltic coating: Service to 150F max.
Asphalt Only: Air Service to 150F max.
Cement w/o asphalt: Sea water, non-septic gravity sewer, reclaim water
*NOTE: For systems designed to convey materials above 150F, contact Tyler Union for adjusted pressure rating of the fittings
ANSI/AWWA C104/A21.4 - Approved Field Repair Method for Cement-Mortar Lined Fittings:
1. Remove the damaged portion or area of the lining down to the metal surface, making sure any remaining lining edges
are undercut slightly or perpendicular to the fitting wall.
2. Clean the surface of loose debris and any tuberculation or corrosion where the lining was removed.
3. Prepare a stiff mortar from a mixture of sand, cement, and water making sure the mix contains no less than one part
cement to two parts sand by volume.
4. Thoroughly wet the cut out area and the adjoining lining.
5. Apply mortar mix and trowel smooth with the adjoining lining
6. After any surface water has evaporated, but while the patch is still moist, cure the lining as provided.
7. The repaired cement lining can be kept moist by seal (asphaltic) coating or with the use of **wetted burlap bags placed
over the entire waterway opening of the fitting or access point. Once the mortar is applied to the fitting apply the seal
coat by spraying or brushing on the seal coat within 5 to 15 minutes after any surface water has evaporated.
**Note: 1) In instances where seal coat is not used, cure cement as provided for 24 hours after application.
2) In cold weather the patched area should be protected from freezing.
3) If seal coat paint is used during field repair, allow a cure time of 48 hours after the seal coat is
Applied before placing fitting back in service.
Tyler Union Waterworks - Approved Field Repair for Asphaltic Coating of Interior and Exterior Fitting Surfaces:
1. Paint repair to the fitting body or mechanical joint includes use of a hand steel bristle brush to remove loose corrosion.
Wipe area free of dust or debris with a cloth suitable for the task and recoat exterior areas of the fitting with the paint
provided as needed using a standard paint brush sized for the task.
2. Recoating of the cement lining is achieved by wiping the lining with a cloth to remove any loose paint or debris and
then apply paint using a standard size paint brush suitable for the task applying paint to affected areas as needed.
Note:

Pressure washing of cement linings is not recommended. However, if required contact your Tyler Union representative for instructions
before proceeding. Failure to follow these instructions or provide suitable supporting documentation will void the warranty on our lining.
Tyler Union Waterworks Call Centers
Tyler: 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
Anniston: 1501 W. 17th. St. Anniston, Alabama 36201 (800) 226-7601
Corona: 1001 El Camino Ave. Corona, California 92879 (866) 527-8471

58

DOMESTIC PRODUCT SUBMITTAL


SIZES:......
STANDARDS:.....
PRESSURE RATING:...
DEFLECTION:....

Current Revisions Apply for all Listed Standards


2 through 48
ANSI/AWWA C110/A21.10, NFPA 13/24, 3 - 12 UL listed and approved (File - Tyler Union)
Cast of ASTM A536 qualified ductile iron. Date code is cast on and required for traceability.
*Flanged fittings rated at 250 psi. Mechanical joints 2 24 rated at 350 psi and 30 48 at 250 psi.
*Note: With the use of rubber annular ring flange gasket, 2 24 fittings can be rated at 350 psi.
Max joint deflection 2 12, 5 and 14 48, 3. Reduces by 50% at nominal pipe & fitting diameters

NSF-61 & NSF-372:...... Meets all requirements including Annex G, Tyler Unions Underwriters Laboratory listing MH16439.
ASPHALTIC COATING: Per ANSI/AWWA C104/A21.4 and ANSI/AWWA C110/A21.10.
CEMENT LINING:. Per ANSI/AWWA C104/A21.4, with double cement lining available upon request.
EPOXY COATING:... Fusion bonded epoxy per ANSI/AWWA C116/A21.16. Additional coatings available upon request.
BARE FITTINGS:.. Available upon request.
FASTENERS:.. High strength low alloy weathering steel per ANSI/AWWA C111/A21.11 and ASTM A242
INSTALLATION:. Install per AWWA C600/C651 using pipe conforming to ANSI/AWWA C151/A21.51 or AWWA C900/905.

*Tyler Union Waterworks Call Center Contact Information*


Tyler: 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
th
Anniston: 1501 W 17 St. Anniston, AL 36201 (800) 226-7601
Corona: 1001 El Camino Ave. Corona, CA 92879 (866) 527-8471

59

NON-DOMESTIC PRODUCT SUBMITTAL


Current Revisions Apply for all Listed Standards
SIZES:...... 2 through 48
STANDARDS:..... ANSI/AWWA C110/A21.10, NFPA 13/24, 3 - 12 UL listed and approved (File - Tyler Union)
Cast of ASTM A536 qualified ductile iron. Date code is cast on and required for traceability.
PRESSURE RATING:... *Flanged fittings rated at 250 psi. Mechanical joints 2 24 rated at 350 psi and 30 48 at 250 psi.
*Note: With the use of rubber annular ring flange gasket, 2 24 fittings can be rated at 350 psi.
DEFLECTION:.... Max joint deflection 2 12, 5 and 14 48, 3. Reduces by 50% at nominal pipe & fitting diameters
NSF-61 & NSF-372:...... Meets all requirements including Annex G, Tyler Unions Underwriters Laboratory listing MH16439.
ASPHALTIC COATING: Per ANSI/AWWA C104/A21.4 and ANSI/AWWA C110/A21.10.
CEMENT LINING:. Per ANSI/AWWA C104/A21.4, with double cement lining available upon request.
EPOXY COATING:... Fusion bonded epoxy per ANSI/AWWA C116/A21.16. Additional coatings available upon request.
BARE FITTINGS:.. Available upon request.
FASTENERS:.. High strength low alloy weathering steel per ANSI/AWWA C111/A21.11 and ASTM A242
INSTALLATION:. Install per AWWA C600/C651 using pipe conforming to ANSI/AWWA C151/A21.51 or AWWA C900/905.

*Tyler Union Waterworks Call Center Contact Information*


Tyler: 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
th
Anniston: 1501 W 17 St. Anniston, AL 36201 (800) 226-7601
Corona: 1001 El Camino Ave. Corona, CA 92879 (866) 527-8471

60

DOMESTIC PRODUCT SUBMITTAL


SIZES:......
STANDARDS:.....
PRESSURE RATING:...

DEFLECTION:....

Current Revisions Apply for all Listed Standards


2 through *64 (2 not included in ANSI/AWWA C153)(*Contact Tyler Union for 54-64 information)
ANSI/AWWA C153/A21.53, NFPA 13/24, 3-12 UL and 3-10FM listed & approved (File - Tyler Union)
Cast of ASTM A536 qualified ductile iron. Date code is cast on and required for traceability.
*Flanged fittings rated at 250 psi. Mechanical joints 2 24 rated at 350 psi and 30 48 at 250 psi.
*Note: With the use of rubber annular ring flange gasket, 2 24 fittings can be rated at 350 psi.
Note: Wyes over 12 are not pressure rated. Contact Tyler Union for rating in your application.
Max joint deflection 2 12, 5 and 14 48, 3. Reduces by 50% at nominal pipe & fitting diameters

NSF-61 & NSF-372:...... Meets all requirements including Annex G, Tyler Unions Underwriters Laboratory listing MH16439.
ASPHALTIC COATING: Per ANSI/AWWA C104/A21.4 and ANSI/AWWA C153/A21.53.
CEMENT LINING:. Per ANSI/AWWA C104/A21.4, with double cement lining available upon request.
EPOXY COATING:... Fusion bonded epoxy per ANSI/AWWA C116/A21.16. Additional coatings available upon request.
BARE:... Available upon request
FASTENERS:.. Per ANSI/AWWA C111/A21.11 and/or ASTM A242 high strength low alloy weathering steel
INSTALLATION:. Per AWWA C600 and C651 using pipe conforming to ANSI/AWWA C151/A21.51 or AWWA C900/905.

*Tyler Union Waterworks Contact Information*


Tyler: 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
th
Anniston: 1501 W 17 St. Anniston, AL 36201 (800) 226-7601
Corona: 1001 El Camino Ave. Corona, CA 92879 (866) 527-8471

61

NON-DOMESTIC PRODUCT SUBMITTAL


Current Revisions Apply for all Listed Standards
SIZES:...... 2 through 64 (2 not included in ANSI/AWWA C153 standard)
STANDARDS:..... ANSI/AWWA C153/A21.53, NFPA 13/24, 3-12 UL and 3-10FM listed & approved (File - Tyler Union)
Cast of ASTM A536 qualified ductile iron. Date code is cast on and required for traceability.
PRESSURE RATING:... *Flanged fittings rated at 250 psi. Mechanical joints 2 24 rated at 350 psi and 30 48 at 250 psi.
*Note: With the use of rubber annular ring flange gasket, 2 24 fittings can be rated at 350 psi.
Note: Wyes over 12 are not pressure rated. Contact Tyler Union for rating in your application.
DEFLECTION:.... Max joint deflection 2 12, 5 and 14 48, 3. Reduces by 50% at nominal pipe & fitting diameters
NSF-61 & NSF-372:...... Meets all requirements including Annex G, Tyler Unions Underwriters Laboratory listing MH16439.
ASPHALTIC COATING: Per ANSI/AWWA C104/A21.4 and ANSI/AWWA C153/A21.53.
CEMENT LINING:. Per ANSI/AWWA C104/A21.4, with double cement lining available upon request.
EPOXY COATING:... Fusion bonded epoxy per ANSI/AWWA C116/A21.16. Additional coatings available upon request.
BARE:... Available upon request.
FASTENERS:.. Per ANSI/AWWA C111/A21.11 and/or ASTM A242 high strength low alloy weathering steel
INSTALLATION:. Per AWWA C600 and C651 using pipe conforming to ANSI/AWWA C151/A21.51 or AWWA C900/905.

*Tyler Union Waterworks Contact Information*


Tyler: 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
th
Anniston: 1501 W 17 St. Anniston, AL 36201 (800) 226-7601
Corona: 1001 El Camino Ave. Corona, CA 92879 (866) 527-8471

62

24U-*Mechanical Joint
Retainer Gland
Series 100
Revised 4/2013

SUBMITTAL

(Current revisions for all Standards apply)


SIZES:............................. Series 100 for 3 through 24
STANDARDS:.................. Per ANSI/AWWA C110, C111, and C153; cast with ASTM A536 Ductile Iron.
Sizes 3-12 are recommended for Class 50 through Class 56 ductile pipe
Sizes 14-24 are recommended for Class 53 through Class 56 ductile pipe
DEFLECTION:.................. Maximum recommended deflection of joints is 2 for 3 through 12 and 1 for 14
through 24
BOLTS:............................ ANSI/AWWA C111/A21.11, for assembly use AWWA C153 length standard T-bolts.
The set screws are square headed with Type C knurled cup points, 4140 grade alloy
steel that is heat treated to a Rockwell C 45/53 case hardness and are shipped
assembled in the gland
PRESSURE RATING:........ Refer to chart provided below
NSF-61 & NSF-372:....... Meets all requirements including Annex G, UL Registered
COATING:...................... ANSI/AWWA C104/A21.4 (asphaltic paint that is NSF-61, NSF-372 & Annex G approved)
INSTALLATION:.............. Per Tyler Union instructions below. Note: Not for use on Plain end fittings

T-BOLTS (to secure gland to "hub")


4 to 24 Retainer gland T-bolts torque to 60 ft lbs

SET SCREWS (to secure gland to "pipe")


Set screw recommended torque value is 75 ft lbs

1. Wash bell and plain end with soapy water,


then slip gland and gasket over plain end
with the small side of the gasket and ring
side of of the gland facing the bell.
2. Slip plain end into bell. Brush soapy water
on gasket. This lubricates the gasket and
allows it to slip easily into place. Push
gasket into bell making sure it is evenly in
the bell gasket landing.
3. Slide the gland into position against the
back of the gasket. Align bolt holes, insert
T-bolts and tighten nuts to finger tight.
4. Snug up all T-bolt nuts evenly. Alternating
at 180, tighten the T-bolt nuts to a torque
of: 3 - 60 foot pounds
4 thru 24 - 90 foot pounds.
5. Snug up all set screws evenly. Using a
torque wrench, tighten the set screws
alternating at 180 to the recommended
torque value of 75 foot pounds. If required
double check set screws immediately.

Pressure

Rating,
Size
psi

3
4
6
8
10
12
14
16
18
20
24

350
350
350
250
250
150
250
200
200
200
150

Gland Pipe O.D. D.I. Pipe


O.D.
O.D.
Wall
B
A
Class

7.69
9.12
11.12
13.37
15.62
17.88
20.25
22.50
24.75
27.00
31.50

3.96
4.80
6.90
9.05
11.10
13.20
15.30
17.40
19.50
21.60
25.80

50-56
50-56
50-56
50-56
50-56
50-56
53-56
53-56
53-56
53-56
53-56

No of Size of
Set
Set
Gland Wt w/
Screws Screws
Wt Acces.

4
4
6
9
12
16
20
24
24
28
32

x2
4
x2
5
x2
9
x2
13
x2
17
x2
20
x2 44
x2 54
x2 62
x3
76
x3 103

8
11
16
21
26
28
55
64
72
91
118

* Not included in AWWA C110 or AWWA C153

Tyler:11910 CR 492-Tyler, TX 75706-(800) 527-8478 / Anniston:1501 W. 17th. St.-Anniston, AL 36201-(800) 226-7601


Corona:1001 El Camino Ave.-Corona, CA 92879-(866)527-8471 / Portland: 6204 N. Marine Dr.-Portland, OR 97203-(866) 527-8471

www.tylerunion.com

63

25U-Compact
Mechanical Joint
Tapping Sleeve for

Ductile Iron, Cast Iron, & C900 PVC Pipe


Revised 7/2013

SUBMITTAL

(Current revisions for all Standards apply)

SIZES:....................... For 6-12 PVC/ductile pipe per ANSI/AWWA C900 or C151 & Cast iron pipe
O.D. as provided. Comes with 4"-12" side flanged outlet & tap at branch.
STANDARDS:............ Mechanical and *Flanged joints comply with applicable requirements of
ANSI/AWWA C153 and ASME/ANSI B16.1. Cast with tested and traceable
ASTM A536 ductile iron. Ductile iron Mechanical Joint Tapping Sleeves are
produced in accordance with Tyler Union manufacturers standard. are
Dimension and specification ranges are per the standards as provided.
Note: Recess dimensions are per Manufacturers Standardization Society
standard practice SP-60. Meets requirements of MSS SP-111
PRESSURE RATING:.. 6- 12 Assemblies rated @ 250 PSI.
GASKETS:................. SBR Mechanical Joint and Split gaskets are per ASTM D2000 - AA and
ANSI/AWWA C111/21.11, armor tipped with coiled brass wire spring.
NSF-61& NSF-372:. Meets all requirements including Annex G
ASPHALTIC
COATING:................. ANSI/AWWA C104/A21.4
CEMENT LINING:..... Tapping Sleeves are unlined to ensure
they fit over the pipe being tapped.
FLANGE:................... ASME/ANSI B16.1, Class 125
FLANGE THICKNESS:.ANSI/AWWA C153 and ASME B16.1
BOLTS:.......... ANSI/AWWA C111/A21.11
DEFLECTION:............ Deflection is not recommended
INSTALLATION:........ Per Tyler Union instructions as provided
1.

2.

3.

4.

5.
6.

Clean pipe, insert side gasket into back


half of gasket grooves. Make sure ends are
flush with or slightly protrude into the end
gasket seating area.
Bolt sleeve halves together and trim side
gaskets as necessary. MAKE SURE
SLEEVE WILL ROTATE FREELY ON PIPE.
Install end gaskets, locating cut ends 90
from side gasket If pipe is maximum OD,
stretch gasket to make certain cut ends
match with no gap in between.
Install glands and bolts-rotate sleeve to
desired position. Be sure pipe is centered
inside the sleeve.
Tighten gland bolts alternately, using 80 to
90 foot pounds.
After assembly, PRESSURE TEST ALL
JOINTS BEFORE TAPPING. If additional
tightening is required, release pressure and
relax tension on gland bolts before tightening side bolts.


Dimensions
Size
A
B
C
D
E
F
Min.
Max.
DI

6x4
6
8x4
8x6
8
10x4
10x6
10x8
10
12x4
12x6
12x8
12x10
12

5.016
7.016
5.016
7.016
9.016
5.016
7.016
9.016
11.016
5.016
7.016
9.016
11.016
13.016

.250
.312
.250
.312
.312
.250
.312
.312
.312
.250
.312
.312
.312
.312

7.50
9.50
7.50
9.50
11.75
7.50
9.50
11.75
14.25
7.50
9.50
11.75
14.25
17.00

15.75
15.75
16.50
16.50
16.50
24.00
24.00
24.00
24.00
26.50
26.50
26.50
26.50
26.50

8.00
8.00
9.00
9.00
9.00
11.00
11.00
11.00
11.00
12.00
12.00
12.00
12.00
12.00

12.75
12.75
13.375
13.375
13.375
20.75
20.75
20.75
20.75
23.25
23.25
23.25
23.25
23.25

6.85
6.85
9.00
9.00
9.00
11.04
11.04
11.04
11.04
13.14
13.14
13.14
13.14
13.14

7.15
7.15
9.35
9.35
9.35
11.45
11.45
11.45
11.45
13.56
13.56
13.56
13.56
13.56

104
108
134
140
148
236
240
246
257
273
286
292
303
320

Tyler:11910 CR 492-Tyler, TX 75706-(800) 527-8478


Anniston: 1501 W. 17th.-St. Anniston, AL 36201-(800) 226-7601
Corona: 1001 El camino Ave.-Corona, CA 92879-(866) 527-8471 Portland: 6204 N. Marine Dr.-Portland, OR 97203-(866) 527-8471
www.tylerunion.com
64

DOMESTIC PRODUCT SUBMITTAL


SIZES:......
STANDARDS:.....
PRESSURE RATING:...

DEFLECTION:....

Current Revisions Apply for all Listed Standards


4 through 24
ANSI/AWWA C153/A21.53, NFPA 13/24, 4 - 12 UL listed and approved (File - Tyler Union)
Cast of ASTM A536 qualified ductile iron. Date code is cast on and required for traceability.
*Flanged fittings rated at 250 psi. Push on joints 4 24 rated at 350 psi.
*Note: With the use of rubber annular ring flange gasket, 4 24 fittings can be rated at 350 psi.
Note: Wyes over 12 are not pressure rated. Contact Tyler Union for rating in your application.
Max joint deflection 4 12, 5 and 14 24, 3. Reduces by 50% at nominal pipe & fitting diameters

NSF-61 & NSF-372:...... Meets all requirements including Annex G, Tyler Unions Underwriters Laboratory listing MH16439.
ASPHALTIC COATING: Per ANSI/AWWA C104/A21.4 and ANSI/AWWA C153/A21.53.
CEMENT LINING:. Per ANSI/AWWA C104/A21.4, with double cement lining available upon request.
EPOXY COATING:... Fusion bonded epoxy per ANSI/AWWA C116/A21.16. Additional coatings available upon request.
BARE:... Available upon request.
FASTENERS:.. Per ANSI/AWWA C111/A21.11 and/or ASTM A242 high strength low alloy weathering steel
RESTRAINING LUGS:.. *Lugs provided on 16 and smaller fittings. Lug pattern accommodates most gripper type restraints.
*Note: With sufficient lead time to adapt tooling, restraining lugs are available on 18-24 fittings.
INSTALLATION:. Per AWWA C600 and C651 using pipe conforming to ANSI/AWWA C151/A21.51 or AWWA C900/905.
Designed for use with TYTON and McWane Sure Stop gaskets. Contact Tyler Union regarding the
installation or use of other gasket types and/or gasket manufacturers.

*Tyler Union Waterworks Contact Information*


Tyler: 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
th
Anniston: 1501 W 17 St. Anniston, AL 36201 (800) 226-7601
Corona: 1001 El Camino Ave. Corona, CA 92879 (866) 527-8471

65

NON-DOMESTIC PRODUCT SUBMITTAL


Current Revisions Apply for all Listed Standards
SIZES:...... 4 through 24
STANDARDS:..... ANSI/AWWA C153/A21.53, NFPA 13/24, 4 - 12 UL listed and approved (File - Tyler Union)
Cast of ASTM A536 qualified ductile iron. Date code is cast on and required for traceability.
PRESSURE RATING:... *Flanged fittings rated at 250 psi. Push on joints 4 24 rated at 350 psi.
*Note: With the use of rubber annular ring flange gasket, 4 24 fittings can be rated at 350 psi.
Note: Wyes over 12 are not pressure rated. Contact Tyler Union for rating in your application.
DEFLECTION:.... Max joint deflection 4 12, 5 and 14 24, 3. Reduces by 50% at nominal pipe & fitting diameters
NSF-61 & NSF-372:...... Meets all requirements including Annex G, Tyler Unions Underwriters Laboratory listing MH16439.
ASPHALTIC COATING: Per ANSI/AWWA C104/A21.4 and ANSI/AWWA C153/A21.53.
CEMENT LINING:. Per ANSI/AWWA C104/A21.4, with double cement lining available upon request.
EPOXY COATING:... Fusion bonded epoxy per ANSI/AWWA C116/A21.16. Additional coatings available upon request.
BARE:... Available upon request.
FASTENERS:.. Per ANSI/AWWA C111/A21.11 and/or ASTM A242 high strength low alloy weathering steel
RESTRAINING LUGS:.. *Lugs provided on 16 and smaller fittings. Lug pattern accommodates most gripper type restraints.
*Note: With sufficient lead time to adapt tooling, restraining lugs are available on 18-24 fittings.
INSTALLATION:. Per AWWA C600 and C651 using pipe conforming to ANSI/AWWA C151/A21.51 or AWWA C900/905.
Designed for use with TYTON and McWane Sure Stop gaskets. Contact Tyler Union regarding the
installation or use of other gasket types and/or gasket manufacturers.

*Tyler Union Waterworks Contact Information*


Tyler: 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
th
Anniston: 1501 W 17 St. Anniston, AL 36201 (800) 226-7601
Corona: 1001 El Camino Ave. Corona, CA 92879 (866) 527-8471

66

DOMESTIC PRODUCT SUBMITTAL


Current Revisions Apply for all Listed Standards
SIZES:...... 2 through *64 (*Contact Tyler Union for 54-64 Flange fitting information)
STANDARDS:..... ANSI/AWWA C110/A21.10, NFPA 13/24, 3 - 12 UL listed and approved (File - Tyler Union)
Cast of ASTM A536 qualified ductile iron. Date code is cast on and required for traceability
PRESSURE RATING:... *2 through 48 flanged fittings rated at 250 psi.
*Note: With the use of rubber annular ring flange gasket, 2 24 fittings can be rated at 350 psi
DEFLECTION:.... Deflection is not recommended for flange joint fittings due to the rigidity of the joint upon
completion of installation.
NSF-61 & NSF-372:...... Meets all requirements including Annex G, Tyler Unions Underwriters Laboratory listing MH16439
COATING: ... Asphaltic or Primer per ANSI/AWWA C104/A21.4, Standard primer is Tnemec Pota Pox 140N-1211
Contact Tyler Union for additional coating options
CEMENT LINING:. Per ANSI/AWWA C104/A21.4, with double cement lining available upon request.
EPOXY COATING:... Fusion bonded epoxy per ANSI/AWWA C116/A21.16. Additional coatings available upon request.
BARE:... Available upon request
FLANGES:... ANSI Class 125 per ASME B16.1 and ANSI/AWWA C111/A21.11
Note: *ANSI Class 250 ASME B16.1 flanged fittings available upon request
Note: *Due to larger bolt sizing and bolt circle, Class 250 flanges are not compatible with
Class 125 flanged fittings. AWWA C110 and AWWA C115 Class 125 flanges are compatible.
FLANGE THICKNESS:. ANSI/AWWA C115/A21.15 standard class 125 template for drilling bolt holes
Note: Drilling templates are in multiples of 4, so that fittings may be made face to in any quarter.
Bolt holes shall straddle the center line.
FASTENERS:.. Per ANSI/AWWA C111/A21.11 and/or ASTM A242 high strength low alloy weathering steel
INSTALLATION:. Per AWWA C600 and C651 using pipe conforming to ANSI/AWWA C151/A21.51

*Tyler Union Waterworks Contact Information*


Tyler: 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
th
Anniston: 1501 W 17 St. Anniston, AL 36201 (800) 226-7601
Corona: 1001 El Camino Ave. Corona, CA 92879 (866) 527-8471

67

NON-DOMESTIC PRODUCT SUBMITTAL


SIZES:......
STANDARDS:.....
PRESSURE RATING:...
DEFLECTION:....

Current Revisions Apply for all Listed Standards


2 through *64 (*Contact Tyler Union for 54-64 Flange fitting information)
ANSI/AWWA C110/A21.10, NFPA 13/24, 3 - 12 UL listed and approved (File - Tyler Union)
Cast of ASTM A536 qualified ductile iron. Date code is cast on and required for traceability
*2 through 48 flanged fittings rated at 250 psi.
*Note: With the use of rubber annular ring flange gasket, 2 24 fittings can be rated at 350 psi
Deflection is not recommended for flange joint fittings due to the rigidity of the joint upon
completion of installation.

NSF-61 & NSF-372:..... Meets all requirements including Annex G, Tyler Unions Underwriters Laboratory listing MH16439
COATING: ... Asphaltic or Primer per ANSI/AWWA C104/A21.4, Standard primer is Tnemec Pota Pox 140N-1211
Contact Tyler Union for additional coating options
CEMENT LINING:. Per ANSI/AWWA C104/A21.4, with double cement lining available upon request.
EPOXY COATING:... Fusion bonded epoxy per ANSI/AWWA C116/A21.16. Additional coatings available upon request.
BARE:... Available upon request
FLANGES:... ANSI Class 125 per ASME B16.1 and ANSI/AWWA C111/A21.11
Note: *ANSI Class 250 ASME B16.1 flanged fittings available upon request
Note: *Due to larger bolt sizing and bolt circle, Class 250 flanges are not compatible with
Class 125 flanged fittings. AWWA C110 and AWWA C115 Class 125 flanges are compatible.
FLANGE THICKNESS:. ANSI/AWWA C115/A21.15 standard class 125 template for drilling bolt holes
Note: Drilling templates are in multiples of 4, so that fittings may be made face to in any quarter.
Bolt holes shall straddle the center line.
FASTENERS:.. Per ANSI/AWWA C111/A21.11 and/or ASTM A242 high strength low alloy weathering steel
INSTALLATION:. Per AWWA C600 and C651 using pipe conforming to ANSI/AWWA C151/A21.51

*Tyler Union Waterworks Contact Information*


Tyler: 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
th
Anniston: 1501 W 17 St. Anniston, AL 36201 (800) 226-7601
Corona: 1001 El Camino Ave. Corona, CA 92879 (866) 527-8471

68

29U-Domestic Heavy
Duty Cast Iron Curb, Service,
& Valve Boxes + Components
Revised 04/2013

SUBMITTAL

(Current Revisions for All Standards Apply)


SIZES:............................. Adjustable Slip and Screw type with standard assembled lengths ranging from 19 to
72 (Lengths noted do not include the addition of risers, extensions, and/or bases).
See the Catalog or List Price guide for access., lids, rings, bases, risers, meter covers, etc.
STANDARDS:.................. Produced with Class 35 cast iron in accordance with and meeting all applicable terms
and provisions of ASTM A-48. All Tyler Union valve boxes when properly installed are
suitable for use in conjunction with projects utilizing American Association of State
Highway and Transportation Officials (AASHTO) standards and provisions.
INSTALLATION:.............. Per AWWA M44, Manual of Water Supply Practices
COATING:....................... The asphaltic bituminous coating is applied to a minimum thickness of 1.5 mil and the
coating once dry is neither brittle when exposed to cold or sticky when exposed to the sun.
For 4 to 12 Valves
5 Shaft, Screw Type

For 3 to 20 Valves
5 Shaft, Screw Type

For 4 to 12 Valves
5 Shaft, Slip Type

For 4 to 12 Valves
5 Shaft, Slip Type

6850 SCREW TYPE


VALVE BOX
Cast Iron - 2 piece

6860 SCREW TYPE


VALVE BOX
Cast Iron - 3 piece

6855 SLIP TYPE


VALVE BOX
Cast Iron - 2 piece

7126 SLIP TYPE


VALVE BOX


Extension
Components
Height
10T + 15B
19-22
27-32
10T + 24B
16T + 24B
27-37
16T + 30B
33-43
16T + 36B
39-50
26T + 30B
36-52
39-60
26T + 36B
26T + 24B + #60 Ext 53-71
26T + 36B + #60 Ext 64-82


Components)
10T + 12B
10T + 18B
16T + 24B
16T + 30B
16T + 36B
26T + 30B
26T + 36B

Extension
Height
27-37
33-42
39-49
45-54
51-60
45-66
51-72

NOTE: Base Required,


Order Separately


Components
10T
10T
16T
16T
16T
26T
26T
26T
26T

+
+
+
+
+
+
+
+
+

15B
24B
24B
30B
36B
30B
36B
24B + #60 Ext
36B + #60 Ext

Extension
Height
19-22
27-32
27-37
33-43
39-50
36-52
39-60
53-71
64-82


Extension
Components
Height
26T + 24B
28-48
26T + 30B
34-54
26T + 36B
40-60
26T + 24B + #60 Ext 52-72
26T + 36B + #60 Ext 60-80
NOTE: Use the 6855 Bottoms
with these Tops

For to 2 Curbstops
6500 SCREW TYPE
CURB / SERVICE BOX

Extension
Componets
In Inches
18T & 27B
30-42
18T & 33B
36-48
24T & 33B
36-54
24T & 39B
42-60
30T & 39B
41-64
*Enlarged Base Available

T = Top
B = Bottom
EXT = Extension

Tyler:11910 CR 492-Tyler,TX 75706-(800) 527-8478


Anniston:1501 W. 17th Street-Anniston, AL 36201-(800) 226-7601
Corona:1001 El Camino Ave.-Corona, CA 92879-(866) 527-8471 Portland: 6204 N. Marine Dr.-Portland, OR 97203-(866) 527-8471

www.tylerunion.com

69

30U-Non-Domestic
*Standard & Heavy
Duty Valve & Service
Boxes + Components
Revised 04/2013

SUBMITTAL

(Current revisions for all Standards apply)

SIZES:..........................Adjustable Slip and Screw type with standard assembled lengths ranging from
15 to 72 (Lengths do not include risers, bases, and/or extensions). See the
Catalog or List Price guide for acc., lids, rings, bases, risers, meter covers, etc.
STANDARDS:...............Produced with cast iron in accordance with and meeting all applicable terms
and provisions of ASTM A-48. All Tyler Union valve boxes when properly
installed are suitable for use in conjunction with projects utilizing American
Association of State and Highway Transportation Officials (AASHTO) standards.
INSTALLATION:...........Per AWWA M44, Manual of Water Supply Practices
COATING:....................The asphaltic bituminous coating is applied to a minimum thickness of 1.5 mil and
the coating once dry is neither brittle when cold or sticky when eposed to the sun.
For 4 to 12 Valves
5 Shaft, Screw Type

For 3 to 20 Valves
5 Shaft, Screw Type

For 4 to 12 Valves
5 Shaft, Slip Type

6850 SCREW TYPE


VALVE BOX
Cast Iron - 2 piece

6860 SCREW TYPE


VALVE BOX
Cast Iron - 3 piece

6855 SLIP TYPE


VALVE BOX
Cast Iron - 2 piece


Components
10T
10T
16T
16T
16T
26T
26T
26T
26T

+
+
+
+
+
+
+
+
+

Extension
Height

15B
24B
24B
30B
36B
30B
36B
24B + #60 Ext
36B + #60 Ext

19-22
27-32
27-37
33-43
39-50
36-52
39-60
53-71
64-82


Components)
10T
10T
16T
16T
16T
26T
26T
16T
26T
26T

+
+
+
+
+
+
+
+
+
+

Extension
Height

12B
27-37
18B
33-42
24B
39-49
30B
45-54
36B
51-60
30B
45-66
36B
51-72
24B + #60 Ext 63-72
24B + #60 Ext 63-84
36B + #60 Ext 74-94


Components
10T
10T
16T
16T
16T
26T
26T
26T
26T

+
+
+
+
+
+
+
+
+

15B
24B
24B
30B
36B
30B
36B
24B + #60 Ext
36B + #60 Ext

Extension
Height
19-22
27-32
27-37
33-43
39-50
36-52
39-60
53-71
64-82

B = Bottom

6500 SCREW TYPE


CURB / SERVICE BOX

Extension
Componets
In Inches
12T
12T
15T
15T
15T
18T
18T
24T
24T
30T

+
+
+
+
+
+
+
+
+
+

12B
15B
15B
21B
27B
27B
33B
33B
39B
39B

15-21
18-24
21-27
24-33
30-39
30-42
36-48
36-54
42-60
41-64

NOTE: Enlarged Base


Available

NOTE: Base Required,


Order Separately

T = Top

For to 2
Curbstops

EXT = Extension

*Note:Wall thickness of Standard weight boxes is 3/16" and the inside diameter is 1/8" greater than the dimensions provided
11910 CR 492-Tyler, TX 75706 - (800) 527-8478 / 1501 W. 17th St.-Anniston, AL - (800) 226-7601
1001 El Camino Ave.-Corona, CA 92879-(866) 527-8471 / 6204 N. Maine Dr.-Portland, OR 97203-(866)527-8471

www.tylerunion.com

70

31U-Standard Mechanical
& Push-On Joint Gaskets
(SBR, NBR, EPDM, Neoprene, FKM)
Revised 4/2013
Page 1 of 2

SUBMITTAL

(Current revisions for all Standards apply)


Tyler Union Waterworks provides that our *Mechanical and Push-On joint gaskets and dimensions conform to the specifications
in ANSI/AWWA C111/A21.11 (current revision). Markings include size, mold number, gasket manufacturer's mark, country
where molded, and product identification letters. No markings are placed on sealing surfaces per the AWWA C111 standard.
*Note: Push-On and Mechanical Joint transition gasket design standards and markings are not addressed by
ANSI/AWWA C111/A21.11 (current revision). Transition gaskets provided by Tyler Union follow the material
testing standards and specifications established for ANSI/AWWA C111/A21.11 gaskets.
Gasket material is vulcanized styrene butadiene rubber (SBR). Purchaser may request special application elastomers (EPDM,
Nitrile, Neoprene & FKM) which will be identified on all documentation and corresponding gaskets. Gaskets are free of foreign
materials, porous areas, or other defects that make them unfit for the intended use.
Tyler Union gaskets are manufactured under quality control standards and procedures that are maintained by the gasket supplier.
Appropriate documentation is maintained by the manufacturer and available for review upon request. Properties and test methods
for SBR, EPDM, Nitrile, Neoprene and FKM gaskets are as provided.
Property
Hardness, Shore A
Minimum Tensile
Minimum Elongation
Minimum Aging
Maximum Compression Set
Resistance to surface
Ozone cracking

ASTM Test Method


D2240-86
D412-87
D412-87
D572-88
D395-89, Method B
D1149-86

Required Value
75 (+-5)
1500 psi (10MPa)
150 %
60 %
20 %
No cracking

Tyler Union's approved suppliers maintain a quality assurance program that is reviewed and updated on an ongoing basis
to ensure product quality. Tyler Union's gasket suppliers submit gaskets for testing and provide materials for testing to Underwriters
Laboratories, Inc. Tyler Union's gasket providers are recognized under the component program (UL 194/ UL 157) of Underwriters
Laboratories, Inc.. Tyler Union UL approved gaskets meet NSF-61, NSF-372 and Annex G.
Tyler Union provides that our Mechanical and Push-On joint gaskets for potable or wastewater projects will perform as designed
when selected per the chart provided and installed per AWWA C600-10.
SBR (Styrene Butadiene rubber)(Buna-S)
20F to180F Suitable for Water, Wastewater, most moderate chemicals, wet or
Not Recommended for Hydrocarbon Service
dry organic acids, alcohols, ketones, and aldehydes

EPDM (Ethylene Propylene)
-10F to 250F Ideal for water, wastewater, ozone, & strong oxidizing chemicals
Not Recommended for Hydrocarbon Service
May be used on steam and air within its temperature range
CR (Neoprene)

-10F to 200F Recommended for moderate chemicals and acids, oil fats, greases,
many solvents and air with hydrocarbons. Will not support combustion

NBR (Nytril)(Buna-N)(Hycar)
-40F to 250F Ideally suited for gasoline, petrolium products, hydrocarbons, water,

mineral and vegetable oils
*FKM(Fluoroelastomer)
10F to 425F Ideally suited for hydrocarbons, acids, vegetable oils & petrolium
*Check with Customer Service for availability
Gasket Types Offered:


(1)Mechanical Joint std.(2) Push-On Joint std.(3)Mechanical Joint DUO


(4)Mechanical & Push-on Joint Transition(5)Push-on Restraining
(6)Mechanical Joint Armor Tip Conductivity(7)Compact tapping Sleeve

Unless other wise requested by the purchaser upon order placement, all gaskets provided will be of our standard SBR
material.

11910 CR 492 - Tyler,TX 75706 - (800) 527-8478


1501 W. 17th. St. - Anniston, AL 36201 - (800) 226-7601
1001 ElCamino Ave. - Corona, CA 92879 - (866) 527-8471 6204 N. Marine Dr. - Portland, OR 97203 - (866) 527-8471

www.tylerunion.com

71

31U-Standard Mechanical
& Push-On Joint Gaskets
(SBR, NBR, EPDM, Neoprene, FKM)
Page 2 of 2
Mechanical Joint Gasket Dimensions in Inches

MECHANICAL JOINT GASKETS


ANSI/AWWA C111/A21.11
*MJ Tru-Lock Gaskets 30 to 48 inch

Pipe
Size

Pipe
OD

2**
3
4
6
8
10
12
14
16
18
20
24
30
36
42
48

2.50
3.96
4.80
6.90
9.05
11.10
13.20
15.30
17.40
19.50
21.60
25.80
32.00
38.30
44.50
50.80

A
B
C
0.01"

.48
.48
.62
.62
.62
.62
.62
.62
.62
.62
.62
.62

.62
.62
.75
.75
.75
.75
.75
.75
.75
.75
.75
.75

.31
.31
.31
.31
.31
.31
.31
.31
.31
.31
.31
.31

D
1%

2.48
3.86
4.68
6.73
8.85
10.87
12.95
14.99
17.07
19.13
21.20
25.34

E
0.01%

.12
.12
.16
.16
.16
.16
.16
.16
.16
.16
.16
.16

F
0.01"

G
0.02"

.15
.15
.22
.22
.22
.22
.22
.22
.22
.22
.22
.22

1.05
1.05
1.22
1.22
1.22
1.22
1.22
1.22
1.22
1.22
1.22
1.22

.73 .00/*.50 .38/*.50 31.47


.16
.37 .54/*1.16
.73 .00/*.50 8/*.50 37.67
.16
.37 .54/*1.16
.73 .00/*.50 38 43.78
.16 37/*.55 1.54/*1.16
.73 .00/*.50 38/*.50 49.98
.16
.37/*.55 1.54/*1.16
**Not included in AWWA C111. Manufacturer's Standard does meet AWWA C111.

**Mechanical Joint Transition Gasket Dimensions in Inches



Pipe
Size

2
3
4
6

10

A
B
C
0.01"

D
E
1%

F
0.01"

G
0.02"

.57
.62
.31
2.28
.16
.24
1.08
.70
.62
.31
3.45
.16
.37
1.11
.77
.75
.31
4.43
.16
.37
1.26
.76
.75
.31
6.53
.16
.36
1.25
.82
.75
.31
8.50
.16
.42
1.27
.79
.75
.31
10.59
.16
.39
1.26


11910 CR 492 - Tyler,TX 75706 - (800) 527-8478


1501 W. 17th. St. - Anniston, AL 36201 - (800) 226-7601
1001 ElCamino Ave. - Corona, CA 92879 - (866) 527-8471 6204 N. Marine Dr. - Portland, OR 97203 - (866) 527-8471

www.tylerunion.com

72

DOMESTIC PRODUCT SUBMITTAL

BETTER BY DESIGN
SPECIFICATIONS:
Designed and proven to restrain plain end ductile iron pipe conforming to ANSI/AWWA C151/A21.51 in diameters 3 thru 48
Proven for use on heavy wall **Schedule 40 or greater steel pipe in sizes 3- 12 and on all sizes 3 to 16 when pipe O.D. and wall
thickness conforms to C151 **Note: IPS diameter steel pipe requires the use of an MJ Transition gasket
Restraint design conforms with applicable requirements of ANSI/AWWA C111, ANSI/AWWA C153, and ANSI/AWWA C110
Restraint engineered for securing plain end pipe to mechanical joint fittings conforming to ANSI/AWWA C110, C111, and C153
Restraints rated for working water pressure of 350 psi and transitory surges of 100psi for 3 thru 16 and 250 psi for 18 thru 48
Cast of ASTM A536 compliant 65-45-12 ductile iron complete with a cast on date code and country of origin for traceability
Restraints and all components are designed and proven for a 2:1 safety factor based on the pipe pressure rating
Restraint deflection rating when installed on nominal diameter pipe is 3- 3, 4-12 - 5, 14-16 - 2, and 18-48 - 1.5
Standard coating for Domestic restraint is 4-6 mil of TUF-Bond(thermoset polyester for impact, corrosion and UV protection)
Gripping wedges are heat treated to a mininum 420 Brinell Hardness
Gripping wedge, wedge collar bolt, and twist off torque limiting nut shall be e-coated
FM approved for 4 thru 12 applications and UL listed and approved for 3 thru 24 applications
Not recommended for use on plain end fittings
Color coded black for pipe type(ductile/*cast iron/**steel) - *Note: Refer to page 2 for cast iron and page 3 for steel pipe applications

FEATURES & ADVANTAGES:

Torque limiting nut on gripping wedge assembly twists off within a designed torque range eliminating the need for specialized tools
Gripping wedge assembly pivots providing stronger engagement of pipe wall at lower torque requirement (45-60 ft.-lbs.)
Proven restraint technology utilizing fewer gripping wedges in frequently applied diameters, reducing trench time and project cost
Restraints heavy duty construction and design eliminates the need for costly thrust blocks and tie rods
Suitable for Potable and Wastewater applications

ISO 9001-2008 Registered


Product
Source/Type

Name of Project

Listed with Underwriters Laboratory


Name of Contractor

Factory Mutual Approved

Project Engineer

*Tyler Union Waterworks Contact Information*


Tyler: 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
th
Anniston: 1501 W 17 St. Anniston, AL 36201 (800) 226-7601
Corona: 1001 El Camino Ave. Corona, CA 92879 (866) 527-8471

Spec. Section
and/or Project No.

73

SERIES 1000 TLD-DUCTILE TUFGrip - APPLICATION CHART


Size
(Inches)
3
4
6
8
10
12
14
16
18
20
24
30
36
42
48

Part No. - Gland Only


Domestic / Non-Domestic
CALL
515944
515968
515975
515982
515999
516231
516255
516279
516293
516316
CALL
CALL
CALL
CALL

/
/
/
/
/
/
/
/
/
/
/
/
/
/
/

113805
113812
113829
113836
113843
113850
113867
113874
113898
113904
113911
461289
461333
461319
461326

ISO 9001-2008 Registered

Wedge
Qty.

T-Head
Bolt Qty.

Bolt Size

Gland
Weight(lbs.)

Weight
(w/Acc.)

Pressure
Rating

Pipe
O.D.

2
2
3
3
6
8
10
12
12
14
16
20
24
28
32

4
4
6
6
8
8
10
12
12
14
16
20
24
28
32

x 3
x 3.5
x 4
x 4
x 4
x 4
x 4.5
x 4.5
x 4.5
x 4.5
x 5

6.5
7.1
11.2
13.1
26.0
31.5
43.3
54.1
59.8
69.8
90.4
248
277
448
519

10.5
11.8
18.8
20.3
32.5
40.4
53.6
66.3
72.2
83.8
106.9
290
327
512
597

350
350
350
350
350
350
350
350
250
250
250
250
250
250
250

3.96
4.80
6.90
9.05
11.10
13.20
15.30
17.40
19.50
21.60
25.80
32.00
38.30
44.50
50.80

1 x 7.5
1 x 7.5
1-1/4 x 8.5
1-1/4 x 8.5

Listed with Underwriters Laboratory

Factory Mutual Approved

STOP-LOOK :
Extra length T-Head bolts are provided with 30 thru 48 inch restraints to facilitate mechanical joint assembly
For UL/FM Approvals, 3-12 inch were tested at 5of deflection and 14-24 inch were tested at 3 of deflection; all test were to 700 psi
The Series 1000 TUF Grip is specified for use on ductile iron pipe but can be used on some sizes of cast grey iron or pit cast pipe
if the pipe is not severely corroded, is in sound condition, and has an outside diameter compatible with the as provided dimensions
TUF Grip 30 to 48 inch provided with TRU-Lock mechanical joint gasket to ensure pressure ratings and safety factors are met
Installation and hydrostatic testing shall be in accordance with AWWA C600 and AWWA C651
*Tyler Union Waterworks Contact Information*
Tyler: 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
th
Anniston: 1501 W 17 St. Anniston, AL 36201 (800) 226-7601
Corona: 1001 El Camino Ave. Corona, CA 92879 (866) 527-8471
www.tylerunion.com

74

DOMESTIC - TLD TUFGrip

Assembly Steps Series 1000 For Ductile Iron Pipe


Steps : 1 and 2

1.
2.

3.

Step : 3

Insure the beveled pipe end to be joined and mechanical joint socket are clean and free of debris. Slide the BLACK
TUF Grip onto the pipe to be restrained. The TUF Grip compression lip extension must be toward the beveled end of
the pipe to be restrained.
Evenly lubricate the beveled pipe end, pipe wall exterior, and inside surface of the MJ gasket with a lubricant that
meets the requirements of AWWA C111. Now place the **MJ gasket over the plain beveled end of the pipe with the
narrow edge of the tapered gasket toward the beveled end of the pipe to be restrained. **NOTE : For Steel pipe
with IPS diameter in sizes 3-12, use of a MJ Transition gasket is required.
Fully insert the pipe end into the MJ socket pipe landing. Keeping the pipe straight, slide/push the MJ gasket firmly
and evenly into the socket recess. Joint must be kept straight during assembly.
Steps : 4 and 5

4.

5.

6.

7.

Steps : 6 and 7

Push the TUF Grip compression lip extension evenly against the thick side of the gasket and insert T-Head bolts
with the T-Head against the back side of the MJ fitting bolt flange. Use only T-Head bolts and nuts that meet AWWA
C111 requirements. Evenly hand-tighten the nuts on the T-Head bolts making sure the gland is centered around the
pipe and within the MJ socket. If joint deflection is needed, only deflect the pipe in the joint after hand tightening of
all nuts is completed. *Joint deflection is 3 max for 3, 5 max for 4-12, 2 max for 14-16, and 1.5 max for 1848.
*NOTE : Maximum deflection values provided apply with nominal pipe, fitting, and restraint diameters.
Using a wrench, tighten the nuts on the T-Head bolts a few turns at a time in an alternating or star pattern
maintaining equal spacing or distance between the TUF Grip bolt flange and face of the MJ socket bolt flange as the
MJ gasket is compressed. The T-Head bolt and nut torque requirement is 3- 45-60 ft.-lbs., 4- 24-75-90 ft.-lbs.,
30- 36- 100-120 ft.-lbs., and 42- 48- 120-150 ft.-lbs.. DO NOT OVER-TORQUE!
Hand-tighten the torque limiting nut attached to each TUF Grip wedge assembly in a clockwise direction with an
alternating or star pattern until all gripping wedges are in contact with the pipe wall. Rotational direction of torque
limiting nut is indicated by recessed arrow on the face of the nut. With a wrench (box, socket, or pneumatic),
continue to tighten each torque nut turn in an alternating or star pattern around the restraint until all torque
limiting nuts twist off. NEVER turn a torque limiting nut more than turn without turning the remaining torque nuts
an equal amount!
When all torque limiting nuts twist off, the assembly of the mechanical joint is complete.
8.

*Tyler Union Waterworks Contact Information*


Tyler: 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
th
Anniston: 1501 W 17 St. Anniston, AL 36201 (800) 226-7601
Corona: 1001 El Camino Ave. Corona, CA 92879 (866) 527-8471
www.tylerunion.com

75

NON-DOMESTIC PRODUCT SUBMITTAL

BETTER BY DESIGN
SPECIFICATIONS:
Designed and proven to restrain plain end ductile iron pipe conforming to ANSI/AWWA C151/A21.51 in diameters 3 thru 48
Proven for use on heavy wall **Schedule 40 or greater steel pipe in sizes 3- 12 and on all sizes 3 to 16 when pipe O.D. and wall
thickness conforms to C151 **Note: IPS diameter steel pipe requires the use of an MJ Transition gasket
Restraint design conforms with applicable requirements of ANSI/AWWA C111, ANSI/AWWA C153, and ANSI/AWWA C110
Restraint engineered for securing plain end pipe to mechanical joint fittings conforming to ANSI/AWWA C110, C111, and C153
Restraints rated for working water pressure of 350 psi and transitory surges of 100psi for 3 thru 16 and 250 psi for 18 thru 48
Cast of ASTM A536 compliant 65-45-12 ductile iron complete with a cast on date code and country of origin for traceability
Restraints and all components are designed and proven for a 2:1 safety factor based on the pipe pressure rating
Restraint deflection rating when installed on nominal diameter pipe is 3- 3, 4-12 - 5, 14-16 - 2, and 18-48 - 1.5
Standard coating for Non-Domestic restraint is 4-6 mil of *Alkyd resin baking enamel -*Note: Epoxy coatings available upon request
Gripping wedges are heat treated to a mininum 420 Brinell Hardness
Gripping wedge, wedge collar bolt, and twist off torque limiting nut shall be e-coated
FM approved for 4 thru 12 applications and UL listed and approved for 3 thru 24 applications
Not recommended for use on plain end fittings
Color coded black for pipe type(ductile/*cast iron/**steel) - *Note: Refer to page 2 for cast iron and page 3 for steel pipe applications

FEATURES & ADVANTAGES:

Torque limiting nut on gripping wedge assembly twists off within a designed torque range eliminating the need for specialized tools
Gripping wedge assembly pivots providing stronger engagement of pipe wall at lower torque requirement (45-60 ft.-lbs.)
Proven restraint technology utilizing fewer gripping wedges in frequently applied diameters, reducing trench time and project cost
Restraints heavy duty construction and design eliminates the need for costly thrust blocks and tie rods
Suitable for Potable and Wastewater applications

ISO 9001-2008 Registered


Product
Source/Type

Name of Project

Listed with Underwriters Laboratory


Name of Contractor

Factory Mutual Approved

Project Engineer

*Tyler Union Waterworks Contact Information*


Tyler: 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
th
Anniston: 1501 W 17 St. Anniston, AL 36201 (800) 226-7601
Corona: 1001 El Camino Ave. Corona, CA 92879 (866) 527-8471

Spec. Section
and/or Project No.

76

SERIES 1000 TLD-DUCTILE TUFGrip - APPLICATION CHART


Size
(Inches)
3
4
6
8
10
12
14
16
18
20
24
30
36
42
48

Part No. - Gland Only


Domestic / Non-Domestic
CALL
515944
515968
515975
515982
515999
516231
516255
516279
516293
516316
CALL
CALL
CALL
CALL

/
/
/
/
/
/
/
/
/
/
/
/
/
/
/

113805
113812
113829
113836
113843
113850
113867
113874
113898
113904
113911
461289
461333
461319
461326

ISO 9001-2008 Registered

Wedge
Qty.

T-Head
Bolt Qty.

Bolt Size

Gland
Weight(lbs.)

Weight
(w/Acc.)

Pressure
Rating

Pipe
O.D.

2
2
3
3
6
8
10
12
12
14
16
20
24
28
32

4
4
6
6
8
8
10
12
12
14
16
20
24
28
32

x 3
x 3.5
x 4
x 4
x 4
x 4
x 4.5
x 4.5
x 4.5
x 4.5
x 5

6.5
7.1
11.2
13.1
26.0
31.5
43.3
54.1
59.8
69.8
90.4
248
277
448
519

10.5
11.8
18.8
20.3
32.5
40.4
53.6
66.3
72.2
83.8
106.9
290
327
512
597

350
350
350
350
350
350
350
350
250
250
250
250
250
250
250

3.96
4.80
6.90
9.05
11.10
13.20
15.30
17.40
19.50
21.60
25.80
32.00
38.30
44.50
50.80

1 x 7.5
1 x 7.5
1-1/4 x 8.5
1-1/4 x 8.5

Listed with Underwriters Laboratory

Factory Mutual Approved

STOP-LOOK :
Extra length T-Head bolts are provided with 30 thru 48 inch restraints to facilitate mechanical joint assembly
For UL/FM Approvals, 3-12 inch were tested at 5of deflection and 14-24 inch were tested at 3 of deflection; all test were to 700 psi
The Series 1000 TUF Grip is specified for use on ductile iron pipe but can be used on some sizes of cast grey iron or pit cast pipe
if the pipe is not severely corroded, is in sound condition, and has an outside diameter compatible with the as provided dimensions
TUF Grip 30 to 48 inch provided with TRU-Lock mechanical joint gasket to ensure pressure ratings and safety factors are met
Installation and hydrostatic testing shall be in accordance with AWWA C600 and AWWA C651
*Tyler Union Waterworks Contact Information*
Tyler: 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
th
Anniston: 1501 W 17 St. Anniston, AL 36201 (800) 226-7601
Corona: 1001 El Camino Ave. Corona, CA 92879 (866) 527-8471
www.tylerunion.com

77

NON-DOMESTIC - TLD TUFGrip

Assembly Steps Series 1000 For Ductile Iron Pipe


Steps : 1 and 2

1.
2.

3.

Step : 3

Insure the beveled pipe end to be joined and mechanical joint socket are clean and free of debris. Slide the BLACK
TUF Grip onto the pipe to be restrained. The TUF Grip compression lip extension must be toward the beveled end of
the pipe to be restrained.
Evenly lubricate the beveled pipe end, pipe wall exterior, and inside surface of the MJ gasket with a lubricant that
meets the requirements of AWWA C111. Now place the **MJ gasket over the plain beveled end of the pipe with the
narrow edge of the tapered gasket toward the beveled end of the pipe to be restrained. **NOTE : For Steel pipe
with IPS diameter in sizes 3-12, use of a MJ Transition gasket is required.
Fully insert the pipe end into the MJ socket pipe landing. Keeping the pipe straight, slide/push the MJ gasket firmly
and evenly into the socket recess. Joint must be kept straight during assembly.
Steps : 4 and 5

4.

5.

6.

7.

Steps : 6 and 7

Push the TUF Grip compression lip extension evenly against the thick side of the gasket and insert T-Head bolts
with the T-Head against the back side of the MJ fitting bolt flange. Use only T-Head bolts and nuts that meet AWWA
C111 requirements. Evenly hand-tighten the nuts on the T-Head bolts making sure the gland is centered around the
pipe and within the MJ socket. If joint deflection is needed, only deflect the pipe in the joint after hand tightening of
all nuts is completed. *Joint deflection is 3 max for 3, 5 max for 4-12, 2 max for 14-16, and 1.5 max for 1848.
*NOTE : Maximum deflection values provided apply with nominal pipe, fitting, and restraint diameters.
Using a wrench, tighten the nuts on the T-Head bolts a few turns at a time in an alternating or star pattern
maintaining equal spacing or distance between the TUF Grip bolt flange and face of the MJ socket bolt flange as the
MJ gasket is compressed. The T-Head bolt and nut torque requirement is 3- 45-60 ft.-lbs., 4- 24-75-90 ft.-lbs.,
30- 36- 100-120 ft.-lbs., and 42- 48- 120-150 ft.-lbs.. DO NOT OVER-TORQUE!
Hand-tighten the torque limiting nut attached to each TUF Grip wedge assembly in a clockwise direction with an
alternating or star pattern until all gripping wedges are in contact with the pipe wall. Rotational direction of torque
limiting nut is indicated by recessed arrow on the face of the nut. With a wrench (box, socket, or pneumatic),
continue to tighten each torque nut turn in an alternating or star pattern around the restraint until all torque
limiting nuts twist off. NEVER turn a torque limiting nut more than turn without turning the remaining torque nuts
an equal amount!
When all torque limiting nuts twist off, the assembly of the mechanical joint is complete.
8.

*Tyler Union Waterworks Contact Information*


Tyler: 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
th
Anniston: 1501 W 17 St. Anniston, AL 36201 (800) 226-7601
Corona: 1001 El Camino Ave. Corona, CA 92879 (866) 527-8471
www.tylerunion.com

78

SERIES 1000S MJ TLD SPLIT For DUCTILE PIPE


A Proven Third Generation Mechanical Joint Restraint

BETTER BY DESIGN
SPECIFICATIONS:

Designed and proven to restrain plain end ductile iron pipe conforming to ANSI/AWWA C151/A21.51 in diameters 4 thru 12
Restraint design conforms with applicable requirements of ANSI/AWWA C111, ANSI/AWWA C153, and ANSI/AWWA C110
Restraint engineered for securing plain end pipe to mechanical joint fittings conforming to ANSI/AWWA C110, C111, and C153
Rated restraint rated for working water pressure of 350 psi for 4 thru 12 restraints
Cast of ASTM A536 compliant 65-45-12 ductile iron complete with a cast on date code and country of origin for traceability
Restraints and all components are designed and proven for a 2:1 safety factor based on the pipe pressure rating
Deflection rating when installed on AWWA C151 pipe with nominal diameter shall be 3 for 4 thru 12 restraints
Standard coating for Non-Domestic restraint is 4-6 mil of *Alkyd resin baking enamel -*Note: Epoxy coatings available upon request
Gripping wedges are heat treated to a mininum 420 Brinell Hardness
Gripping wedge, wedge collar bolt, and twist off torque limiting nut shall be e-coated
Not recommended for use on plain end fittings
Color coded black for pipe type(ductile pipe/*cast iron pipe) - *Note: Refer to page 2 for cast iron pipe application

FEATURES & ADVANTAGES:

Torque limiting nut on gripping wedge assembly twists off within a designed torque range eliminating the need for specialized tools
Gripping wedge assembly pivots providing stronger engagement of pipe wall at lower torque requirement (45-60 ft.-lbs.)
Proven restraint technology utilizing fewer gripping wedges in frequently applied diameters, reducing trench time and project cost
Restraints heavy duty construction and design eliminates the need for costly thrust blocks and tie rods
Suitable for Potable and Wastewater applications

ISO 9001-2008 Registered


Product
Source/Type

Name of Project

Name of Contractor

Project Engineer

Spec. Section
and/or Project No.

*Tyler Union Waterworks Contact Information*


Tyler: 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
th
Anniston: 1501 W 17 St. Anniston, AL 36201 (800) 226-7601
Corona: 1001 El Camino Ave. Corona, CA 92879 (866) 527-8471
79

SERIES 1000S MJ TLD SPLIT For DUCTILE PIPE

Size (inches)

K2

4.93

5.92

7.03

8.02

7.50

8.98

10.67

7/8

2.20

0.73

9.50

10.98

12.77

7/8

2.24

9.18

0.82

10.17

11.75

13.23

14.92

7/8

2.28

10

0.82

11.23

12.22

14.00

15.70

16.97

7/8

2.37

12

0.93

13.33

14.32

16.25

17.95

19.07

7/8

2.40

0.93

SERIES 1000 TLD-DUCTILE MJ TUFGrip - APPLICATION CHART


Size
(Inches)
4
6
8
10
12

Part # Gland+Accessories
Domestic / Non-Domestic
N/A
N/A
N/A
N/A
N/A

/
/
/
/
/

495918
495925
495932
495949
495956

Wedge
Qty.

T-Head
Bolt Qty.

Bolt Size

Gland
Weight(lbs.)

Weight
(w/Acc.)

Pressure
Rating

Pipe
O.D.

2
3
3
6
8

4
6
6
8
8

x 3.5
x 4
x 4
x 4
x 4

7.1
11.2
13.1
26.0
31.5

11.8
18.8
20.3
32.5
40.4

350
350
350
350
350

4.80
6.90
9.05
11.10
13.20

ISO 9001-2008 Registered


STOP-LOOK :
The Series 1000S TUF Grip is specified for use on ductile iron pipe but can be used on some sizes of cast grey iron or pit cast pipe
as provided (pipe not severely corroded, in sound condition, and with an outside diameter compatible with restraint C dimension)
Installation and hydrostatic testing shall be in accordance with AWWA C600 and AWWA C651
*Tyler Union Waterworks Contact Information*
Tyler: 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
th
Anniston: 1501 W 17 St. Anniston, AL 36201 (800) 226-7601
Corona: 1001 El Camino Ave. Corona, CA 92879 (866) 527-8471
80

Assembly Steps Series 1000S TLD Split For Ductile Iron Pipe
Steps: 1 and 2

1.
2.
3.
4.

Insure the beveled pipe end to be joined and mechanical joint socket are clean and free of debris.
Lubricate the pipe end and exterior plus the inside surface of gasket with joint lubricant that meets the
requirements of AWWA C111. Now place the MJ gasket over the plain beveled end of the pipe with the narrow edge
of the tapered gasket toward the beveled end of the pipe to be restrained.
Fully insert the pipe end into the MJ socket pipe landing. Keeping the pipe straight, slide/push the gasket firmly and
evenly into the MJ socket recess.
Place the two halves of the black TUF Grip around the pipe with the compression lip extension toward the MJ
socket. Join the two restraint halves together with two T-Head bolts. Use only T-Head bolts, gaskets, and nuts that
meet AWWA C111 requirements.
Step: 5

5.

6.

7.
8.

9.

Step: 3 and 4

Steps: 6 and 7

Steps: 8 and 9

With the two T-Head bolts inserted through the restraint, push the TUF Grip lip extension evenly against the thick
side of the MJ gasket. With the TUF Grip restraint against the gasket, the remaining T-Head bolts are inserted with
the T-Head against the back of the MJ fitting bolt flange. Install two additional T-Head bolts with nuts and hand
tighten to secure the restraint to the fitting.
With the restraint secured to the fitting, remove the original assembly T-Head bolts and reinsert with the T-Head
against the back of the MJ fitting bolt flange. Making sure the TUF Grip is centered around the pipes wall, hand
tighten all remaining T-Head bolts and nuts. If joint deflection is needed, only deflect the pipe in the joint after hand
tightening of all nuts is completed. Maximum joint deflection is 3 when pipe and fitting dimensions are nominal.
Using a wrench, tighten the nuts on the T-Head bolts a few turns at a time in an alternating or star pattern. Maintain
equal spacing between the TUF Grip bolt flange and the bolt flange of the MJ socket as the gasket is compressed.
The T-Head bolt and nut torque requirement is 75-90 ft.-lbs. for 4 thru 12 restraints. DO NOT OVER-TORQUE!
Hand-tighten the torque limiting nut attached to the TUF Grip wedge assemblies in a clockwise direction with an
alternating or star pattern until all gripping wedges are in contact with the pipe wall. Rotational direction of torque
limiting nut is indicated by recessed arrow on the face of the nut. With a wrench, continue to tighten each torque
nut turn in an alternating or star pattern until all torque limiting nuts twist off. NEVER turn a torque limiting nut
more than turn without turning the remaining torque nuts an equal amount!
When all torque limiting nuts twist off, the assembly of the mechanical joint restraint is complete.
10.

*Tyler Union Waterworks Contact Information*


Tyler: 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
th
Anniston: 1501 W 17 St. Anniston, AL 36201 (800) 226-7601
Corona: 1001 El Camino Ave. Corona, CA 92879 (866) 527-8471

81

DOMESTIC PRODUCT SUBMITTAL

BETTER BY DESIGN
SPECIFICATIONS:

Proven to restrain plain end PVC pipe in diameters 3 thru 36 and PVCO pipe in diameters 4 thru 12
Restraint design conforms to applicable requirements of ANSI/AWWA C111, ANSI/AWWA C153, and ANSI/AWWA C110
Restraint engineered for securing plain end pipe to mechanical joint fittings conforming to ANSI/AWWA C110, C111, and C153
Rated for working water pressure of 305 psi for 3-12, 235 psi for 14-24, 150 psi for 30, and 125 psi for 36 (details on page 2)
Cast of ASTM compliant 65-45-12 ductile iron complete with cast on date code and country of origin for traceability
Restraint and all components are designed and proven for a 2:1 safety factor based on the PVC and PVCO pipe pressure rating
Deflection rating when installed on pipe with nominal diameter shall be 3 for 3 thru 12, 2 for 14 thru 16, and 1.5 for 18 thru 36
Standard coating for Domestic restraint is 4-6 mil of TUF-Bond(thermoset polyester for impact, corrosion, and UV protection)
Gripping wedge, wedge collar bolt and twist off torque limiting nut shall be e-coated
FM approved for 4 thru 12 applications and UL listed and approved for 3 thru 12 applications
Color coded red for pipe type (C900 PVC/C905 PVC/ *C909 PVCO/D2241 PVC) - *Note: Refer to page 2 for C909 pipe applications

FEATURES & ADVANTAGES:

Torque limiting nut on gripping wedge assembly twists off within a designed torque range eliminating the need for specialized tools
Gripping wedge assembly pivots providing stronger engagement of pipe wall at lower torque requirement (45-60 ft.-lbs.)
Proven restraint technology utilizing fewer gripping wedges in frequently applied diameters, reducing trench time and project cost
There is no washer or spacer to remove when installing restraints on 3 to 12 ASTM D2241 PVC pipe with IPS outside diameter
Restraints heavy duty construction and design eliminates the need for costly thrust blocks and tie rods
Suitable for Potable and Wastewater applications
Approved for use on multiple classes of pipe - Additional pressure ratings and associated pipe classes provided on pages 2 and 3

ISO 9001-2008 Registered


Product
Source/Type

Name of Project

Listed with Underwriters Laboratory


Name of Contractor

Factory Mutual Approved

Project Engineer

*Tyler Union Waterworks Contact Information*


Tyler: 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
th
Anniston: 1501 W 17 St. Anniston, AL 36201 (800) 226-7601
Corona: 1001 El Camino Ave. Corona, CA 92879 (866) 527-8471

Spec. Section
and/or Project No.

82

SERIES 2000 TLP-PVC TUFGrip - APPLICATION CHART


Size
(Inches)
3
4
6
8
10
12
14
16
18
20
24
30
36

Part No. - Gland Only


Domestic / Non-Domestic
CALL
516002
516019
516026
516033
516040
516248
516262
516286
516309
516323
CALL
CALL

/
/
/
/
/
/
/
/
/
/
/
/
/

113928
113935
113942
113959
113973
113980
113997
114000
114017
114024
114031
461302
461357

Wedge
Qty.

T-Head
Bolt Qty.

2
2
3
3
6
8
10
12
12
14
16
20
24

4
4
6
6
8
8
10
12
12
14
16
20
24

Bolt
Size
x 3
x 3.5
x 4
x 4
x 4
x 4
x 4.5
x 4.5
x 4.5
x 4.5
x 5
1 x 7.5
1 x 7.5

Gland
Weight(lbs.)

Weight
(w/Acc.)

*Pressure
Rating

Pipe O.D.
(Inches)

7.0
8.3
12.4
14.9
25.7
34.1
45.1
56.2
62.4
72.9
93.2
251
281

11.0
12.2
18.3
20.8
33.4
42.0
55.4
68.4
74.8
86.9
109.8
293
331

*305 / DR14
*305 / DR14
*305 / DR14
*305 / DR14
*305 / DR14
*305 / DR14
*235 / DR18
*235 / DR18
*235 / DR25
*235 / DR25
*235 / DR25
*150 / DR25
*125 / DR25

3.50
4.50-4.80
6.63-6.90
8.63-9.12
10.75-11.10
12.75-13.20
15.30
17.40
19.50
21.60
25.80
32.00
38.30

*Note: The pressure ratings are rated working water pressures for the restraint. See page 3 for additional ratings.

ISO 9001-2008 Registered

Listed with Underwriters Laboratory

Factory Mutual Approved

STOP-LOOK :

Extra length T-Head bolts are provided with 30- 36 restraints to facilitate mechanical joint assembly per AWWA C600.
For UL/FM Approvals, 3- 12 were tested to 755 psi, 14-16 were tested to 755 psi and 18- 24 inch were tested to 535 psi.
TUF Grip 30-36 inch provided with TRU-Lock mechanical joint gasket to ensure pressure rating & safety factors are met.
Mechanical joint T-head bolt torques for C909 applications are as provided; *55-65 ft.-lbs for 4 to 8 and *65 to 75 ft.-lbs. for
10 to 12 assembly. You must specifiy restraints are for C909 PVCO pipe upon order placement. Call for availability.
Installation and hydrostatic testing shall be in accordance with AWWA C600 and AWWA C651.
TUF Grip 4 to 24 restraints shall meet the requirementsof ASTM F1674, current revision.
*Tyler Union Waterworks Contact Information*
Tyler: 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
th
Anniston: 1501 W 17 St. Anniston, AL 36201 (800) 226-7601
Corona: 1001 El Camino Ave. Corona, CA 92879 (866) 527-8471
www.tylerunion.com

83

DOMESTIC PRODUCT SUBMITTAL

**ADDITIONAL SERIES 2000 TLP-TUF GRIP RESTRAINT RATINGS


AWWA C900
AWWA C905
ASTM D2241
SIZE (Inches)
DR14
DR18 DR25
DR18
DR25
DR32.5 SDR17 SDR21 SDR26
3
4
6
8
10
12
14
16
18
20
24
30
36

305
305
305
305
305
-

235
235
235
235
235
-

165
165
165
165
165
-

235
235
200
200
165
-

165
165
165
165
165
165
125

125
125
125
125
125

250
250
250
250
250
250
-

200
200
200
200
200
200
-

160
160
160
160
160
-

**Note: Pressure Ratings for Ordinary Water Works Restraint Application with Transitory Surges Only
**Note: AWWA C909 PVCO Restraint Pressure Rating is per the Pressure Rating Listed on the Pipe

Assembly steps for (3-12 ASTM D2241 IPS PVC), (4-12 AWWA C909 PVCO), and (4-36 AWWAC900/C905 PVC)
Steps: 1 and 2

1.
2.
3.
4.

5.

6.

7.

Step: 3

Steps: 4 and 5

Steps: 6 and 7

Insure the beveled pipe end to be joined and mechanical joint socket are clean and free of debris. Slide the RED
TUF Grip onto the beveled end of the pipe to be restrained. The TUF Grip compression lip extension must be toward
the beveled end of the pipe being restrained.
Evenly lubricate the beveled pipe end, exterior pipe wall, and inside surface of the gasket with a lubricant that
meets the requirements of AWWA C111. Now place the **MJ gasket over the plain beveled end of the pipe with the
narrow edge of the tapered gasket toward the pipe end. **NOTE: Use MJ transition gasket with IPS diameter pipe.
Fully insert the beveled pipe end into the MJ socket pipe landing. Keeping the pipe straight in the MJ socket,
slide/push the MJ gasket firmly and evenly into the MJ socket recess. Joint must be kept straight during assembly.
Push the TUF Grip compression lip extension evenly against the thick side of the MJ gasket and insert all T-Head
bolts with nuts. Use only T-Head bolts and nuts that meet AWWA C111 requirements. With the TUF Grip restraint lip
extension against the MJ gasket, evenly hand-tighten the nuts on the T--Head bolts making sure the restraint body is
centered on the pipe and within in the MJ socket. If joint deflection is needed, deflect the pipe only after hand
tightening of all nuts is completed. Joint deflection is 3 max for 3, 5 max for 4-12, 2 max for 14-16, 1.5 max
for 18-36. NOTE: Maximum deflection values provided apply with nominal pipe, fitting, and restraint diameters.
Using a wrench, tighten the T-Head bolts and nuts a few turns at a time in an alternating or star pattern. Maintain
equal spacing or distance between the TUF Grip bolt flange and the MJ socket bolt flange as the MJ gasket is
compressed. Repeat the process in an alternating pattern for all T-Head bolts and nuts. The T-Head bolt and nut
torque requirement for restraints is 3- 45-60 ft.-lbs., 4- 24-75-90 ft.-lbs., and 30- 36- 100-120 ft.-lbs.
NOTE: The C909 PVCO T-Head bolt and nut torque is 55-65 ft.-lbs. for 4-8 and 65-75 ft.-lbs. for 10-12restraints.
DO NOT OVER-TORQUE T-HEAD BOLTS and NUTS WHEN ASSEMBLING PVC and PVCO PIPE!
**Hand-tighten the torque limiting nuts attached to the TUF Grip wedge assemblies in a clockwise direction with an
alternating or star pattern until all gripping wedges are in contact with the pipe wall. Rotational direction of torque
nut is indicated by recessed arrow on the face of the nut. With a wrench (box, socket, or pneumatic), continue to
tighten each torque nut turn in an alternating or star pattern around the restraint until all torque limiting nuts twist
off. NEVER turn a torque limiting nut more than turn without turning the remaining torque nuts an equal amount!
**NOTE: For IPS and PVCO applications, ensure step 5 is completed before engaging wedges. Failure to comply
will result in excessive pipe wall deflection and torque nuts will not twist off as designed.
When all torque limiting nuts twist off, the mechanical joint and restraint assembly are complete.
*Tyler Union Waterworks Contact Information*
Tyler: 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
th
Anniston: 1501 W 17 St. Anniston, AL 36201 (800) 226-7601
Corona: 1001 El Camino Ave. Corona, CA 92879 (866) 527-8471
84
www.tylerunion.com

NON-DOMESTIC PRODUCT SUBMITTAL

BETTER BY DESIGN
SPECIFICATIONS:

Proven to restrain plain end PVC pipe in diameters 3 thru 36 and PVCO pipe in diameters 4 thru 12
Restraint design conforms to applicable requirements of ANSI/AWWA C111, ANSI/AWWA C153, and ANSI/AWWA C110
Restraint engineered for securing plain end pipe to mechanical joint fittings conforming to ANSI/AWWA C110, C111, and C153
Rated for working water pressure of 305 psi for 3-12, 235 psi for 14-24, 150 psi for 30, and 125 psi for 36 (details on page 2)
Cast of ASTM compliant 65-45-12 ductile iron complete with cast on date code and country of origin for traceability
Restraint and all components are designed and proven for a 2:1 safety factor based on the PVC and PVCO pipe pressure rating
Deflection rating when installed on pipe with nominal diameter shall be 3 for 3 thru 12, 2 for 14 thru 16, and 1.5 for 18 thru 36
Standard coating for Non-Domestic restraint is 4-6 mil of *Alkyd resin baking enamel - *Note: Epoxy coatings available upon request
Gripping wedge, wedge collar bolt and twist off torque limiting nut shall be e-coated
FM approved for 4 thru 12 applications and UL listed and approved for 3 thru 12 applications
Color coded red for pipe type (C900 PVC/C905 PVC/ *C909 PVCO/D2241 PVC) - *Note: Refer to page 2 for C909 pipe applications

FEATURES & ADVANTAGES:

Torque limiting nut on gripping wedge assembly twists off within a designed torque range eliminating the need for specialized tools
Gripping wedge assembly pivots providing stronger engagement of pipe wall at lower torque requirement (45-60 ft.-lbs.)
Proven restraint technology utilizing fewer gripping wedges in frequently applied diameters, reducing trench time and project cost
There is no washer or spacer to remove when installing restraints on 3 to 12 ASTM D2241 PVC pipe with IPS outside diameter
Restraints heavy duty construction and design eliminates the need for costly thrust blocks and tie rods
Suitable for Potable and Wastewater applications
Approved for use on multiple classes of pipe - Additional pressure ratings and associated pipe classes provided on pages 2 and 3

ISO 9001-2008 Registered


Product
Source/Type

Name of Project

Listed with Underwriters Laboratory


Name of Contractor

Factory Mutual Approved

Project Engineer

*Tyler Union Waterworks Contact Information*


Tyler: 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
th
Anniston: 1501 W 17 St. Anniston, AL 36201 (800) 226-7601
Corona: 1001 El Camino Ave. Corona, CA 92879 (866) 527-8471

Spec. Section
and/or Project No.

85

SERIES 2000 TLP-PVC TUFGrip - APPLICATION CHART


Size
(Inches)
3
4
6
8
10
12
14
16
18
20
24
30
36

Part No. - Gland Only


Domestic / Non-Domestic
CALL
516002
516019
516026
516033
516040
516248
516262
516286
516309
516323
CALL
CALL

/
/
/
/
/
/
/
/
/
/
/
/
/

113928
113935
113942
113959
113973
113980
113997
114000
114017
114024
114031
461302
461357

Wedge
Qty.

T-Head
Bolt Qty.

2
2
3
3
6
8
10
12
12
14
16
20
24

4
4
6
6
8
8
10
12
12
14
16
20
24

Bolt
Size
x 3
x 3.5
x 4
x 4
x 4
x 4
x 4.5
x 4.5
x 4.5
x 4.5
x 5
1 x 7.5
1 x 7.5

Gland
Weight(lbs.)

Weight
(w/Acc.)

*Pressure
Rating

Pipe O.D.
(Inches)

7.0
8.3
12.4
14.9
25.7
34.1
45.1
56.2
62.4
72.9
93.2
251
281

11.0
12.2
18.3
20.8
33.4
42.0
55.4
68.4
74.8
86.9
109.8
293
331

*305 / DR14
*305 / DR14
*305 / DR14
*305 / DR14
*305 / DR14
*305 / DR14
*235 / DR18
*235 / DR18
*235 / DR25
*235 / DR25
*235 / DR25
*150 / DR25
*125 / DR25

3.50
4.50-4.80
6.63-6.90
8.63-9.12
10.75-11.10
12.75-13.20
15.30
17.40
19.50
21.60
25.80
32.00
38.30

*Note: The pressure ratings are rated working water pressures for the restraint. See page 3 for additional ratings.

ISO 9001-2008 Registered

Listed with Underwriters Laboratory

Factory Mutual Approved

STOP-LOOK :

Extra length T-Head bolts are provided with 30- 36 restraints to facilitate mechanical joint assembly per AWWA C600.
For UL/FM Approvals, 3- 12 were tested to 755 psi, 14-16 were tested to 755 psi and 18- 24 inch were tested to 535 psi.
TUF Grip 30-36 inch provided with TRU-Lock mechanical joint gasket to ensure pressure rating & safety factors are met.
Mechanical joint T-head bolt torques for C909 applications are as provided; *55-65 ft.-lbs for 4 to 8 and *65 to 75 ft.-lbs. for
10 to 12 assembly. You must specifiy restraints are for C909 PVCO pipe upon order placement. Call for availability.
Installation and hydrostatic testing shall be in accordance with AWWA C600 and AWWA C651.
TUF Grip 4 to 24 restraints shall meet the requirementsof ASTM F1674, current revision.
*Tyler Union Waterworks Contact Information*
Tyler: 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
th
Anniston: 1501 W 17 St. Anniston, AL 36201 (800) 226-7601
Corona: 1001 El Camino Ave. Corona, CA 92879 (866) 527-8471
www.tylerunion.com

86

NON-DOMESTIC PRODUCT SUBMITTAL


**ADDITIONAL SERIES 2000 TLP-TUF GRIP RESTRAINT RATINGS
AWWA C900
AWWA C905
ASTM D2241
SIZE (Inches)
DR14
DR18 DR25
DR18
DR25
DR32.5 SDR17 SDR21 SDR26
3
4
6
8
10
12
14
16
18
20
24
30
36

305
305
305
305
305
-

235
235
235
235
235
-

165
165
165
165
165
-

235
235
200
200
165
-

165
165
165
165
165
165
125

125
125
125
125
125

250
250
250
250
250
250
-

200
200
200
200
200
200
-

160
160
160
160
160
-

**Note: Pressure Ratings for Ordinary Water Works Restraint Application with Transitory Surges Only
**Note: AWWA C909 PVCO Restraint Pressure Rating is per the Pressure Rating Listed on the Pipe

Assembly steps for (3-12 ASTM D2241 IPS PVC), (4-12 AWWA C909 PVCO), and (4-36 AWWAC900/C905 PVC)
Steps: 1 and 2

1.
2.
3.
4.

5.

6.

7.

Step: 3

Steps: 4 and 5

Steps: 6 and 7

Insure the beveled pipe end to be joined and mechanical joint socket are clean and free of debris. Slide the RED
TUF Grip onto the beveled end of the pipe to be restrained. The TUF Grip compression lip extension must be toward
the beveled end of the pipe being restrained.
Evenly lubricate the beveled pipe end, exterior pipe wall, and inside surface of the gasket with a lubricant that
meets the requirements of AWWA C111. Now place the **MJ gasket over the plain beveled end of the pipe with the
narrow edge of the tapered gasket toward the pipe end. **NOTE: Use MJ transition gasket with IPS diameter pipe.
Fully insert the beveled pipe end into the MJ socket pipe landing. Keeping the pipe straight in the MJ socket,
slide/push the MJ gasket firmly and evenly into the MJ socket recess. Joint must be kept straight during assembly.
Push the TUF Grip compression lip extension evenly against the thick side of the MJ gasket and insert all T-Head
bolts with nuts. Use only T-Head bolts and nuts that meet AWWA C111 requirements. With the TUF Grip restraint lip
extension against the MJ gasket, evenly hand-tighten the nuts on the T--Head bolts making sure the restraint body is
centered on the pipe and within in the MJ socket. If joint deflection is needed, deflect the pipe only after hand
tightening of all nuts is completed. Joint deflection is 3 max for 3, 5 max for 4-12, 2 max for 14-16, 1.5 max
for 18-36. NOTE: Maximum deflection values provided apply with nominal pipe, fitting, and restraint diameters.
Using a wrench, tighten the T-Head bolts and nuts a few turns at a time in an alternating or star pattern. Maintain
equal spacing or distance between the TUF Grip bolt flange and the MJ socket bolt flange as the MJ gasket is
compressed. Repeat the process in an alternating pattern for all T-Head bolts and nuts. The T-Head bolt and nut
torque requirement for restraints is 3- 45-60 ft.-lbs., 4- 24-75-90 ft.-lbs., and 30- 36- 100-120 ft.-lbs.
NOTE: The C909 PVCO T-Head bolt and nut torque is 55-65 ft.-lbs. for 4-8 and 65-75 ft.-lbs. for 10-12restraints.
DO NOT OVER-TORQUE T-HEAD BOLTS and NUTS WHEN ASSEMBLING PVC and PVCO PIPE!
**Hand-tighten the torque limiting nuts attached to the TUF Grip wedge assemblies in a clockwise direction with an
alternating or star pattern until all gripping wedges are in contact with the pipe wall. Rotational direction of torque
nut is indicated by recessed arrow on the face of the nut. With a wrench (box, socket, or pneumatic), continue to
tighten each torque nut turn in an alternating or star pattern around the restraint until all torque limiting nuts twist
off. NEVER turn a torque limiting nut more than turn without turning the remaining torque nuts an equal amount!
**NOTE: For IPS and PVCO applications, ensure step 5 is completed before engaging wedges. Failure to comply
will result in excessive pipe wall deflection and torque nuts will not twist off as designed.
When all torque limiting nuts twist off, the mechanical joint and restraint assembly are complete.
*Tyler Union Waterworks Contact Information*
Tyler: 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
th
Anniston: 1501 W 17 St. Anniston, AL 36201 (800) 226-7601
Corona: 1001 El Camino Ave. Corona, CA 92879 (866) 527-8471
www.tylerunion.com
87

SERIES 2000S MJ TLP SPLIT For PVC PIPE


A Proven Third Generation Mechanical Joint Restraint

Better by Design
SPECIFICATIONS:

Proven to restrain plain end PVC pipe in diameters 4 thru 12


Restraint design conforms to applicable requirements of ANSI/AWWA C111, ANSI/AWWA C153, and ANSI/AWWA C110
Restraint engineered for securing plain end pipe to mechanical joint fittings conforming to ANSI/AWWA C110, C111, and C153
Restraint rated for working water pressure of 305 psi for 4 thru 12 inch restraints (details on page 2)
Cast of ASTM A536 compliant 65-45-12 ductile iron complete with cast on date code and country of origin for traceability
Restraints and all components are designed and proven for a 2:1 safety factor based on the PVC pipe pressure rating
Deflection rating when installed on AWWA C900 pipe with nominal diameter shall be 3 for 4 thru 12 restraints
Standard coating for Non-Domestic restraint is 4-6 mil of *Alkyd resin baking enamel - *Note: Epoxy coatings available upon request
Gripping wedge, wedge collar bolt and twist off torque limiting nut shall be e-coated
Restraint body color coded red for pipe type (AWWA C900 PVC and ASTM D2241)

FEATURES & ADVANTAGES:

Unique Split design assembles using standard T-bolts and without additional accessories in sizes 6 thru 12
Torque limiting nut on gripping wedge assembly twists off within a designed torque range eliminating the need for specialized tools
Gripping wedge assembly pivots providing stronger engagement of pipe wall at lower torque requirement (45-60 ft.-lbs.)
Proven restraint technology utilizing fewer gripping wedges in frequently applied diameters, reducing trench time and project cost
There is no washer or spacer to remove when installing restraints on 4 to 12 ASTM D2241 PVC pipe with IPS outside diameter
Restraints heavy duty construction and design eliminates the need for costly thrust blocks and tie rods
Suitable for Potable and Wastewater applications
Approved for use on multiple classes of pipe - Additional pressure ratings and associated pipe classes provided on page 2

ISO 9001-2008 Registered


Product
Source/Type

Name of Project

Name of Contractor

Project Engineer

*Tyler Union Waterworks Contact Information*


Tyler: 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
th
Anniston: 1501 W 17 St. Anniston, AL 36201 (800) 226-7601
Corona: 1001 El Camino Ave. Corona, CA 92879 (866) 527-8471

Spec. Section
and/or Project No.

88

SERIES 2000S MJ TLP SPLIT For PVC PIPE

Size (inches)

K2

4
6
8
10
12

4.93
7.03
9.18
11.23
13.33

5.92
8.02
10.17
12.22
14.32

7.50
9.50
11.75
14.00
16.25

8.98
10.98
13.23
15.70
17.95

10.67
12.77
14.92
16.97
19.07

7/8
7/8
7/8
7/8
7/8

2.20
2.24
2.28
2.37
2.40

0.73
0.82
0.82
0.93
0.93

SERIES 2000S TLP-PVC MJ TUFGrip - APPLICATION CHART


Size
(Inches)

Part # Gland+Accessories
Domestic / Non-Domestic

Wedge
Qty.

T-Head
Bolt Qty.

Bolt
Gland
Weight
Size
Weight(lbs.)
(w/Acc.)
x 3.5
4
N/A
/
537052
2
4
8.3
12.2
6
N/A
/
537069
3
6
x 4
12.4
18.3
x 4
8
N/A
/
537076
3
6
14.9
20.8
10
N/A
/
537083
6
8
x 4
25.7
33.4
x 4
12
N/A
/
537090
8
8
34.1
42.0
*Note: The Pressure Ratings are Rated Working Water Pressures for the Restraint.

*Pressure
Rating

Pipe O.D.
(Inches)

*305 / DR14
*305 / DR14
*305 / DR14
*305 / DR14
*305 / DR14

4.50-4.80
6.63-6.90
8.63-9.12
10.75-11.10
12.75-13.20

**ADDITIONAL SERIES 2000S SPLIT TLP-PVC MJ TUFGrip RESTRAINT RATINGS


PIPE TYPE
SIZE (Inches)

DR14

4
6
8
10
12

305
305
305
305
305

AWWA C900
DR18
235
235
235
235
235

DR25

SDR17

150
150
150
150
150

250
250
250
250
250

ASTM D2241
SDR21

SDR26

200
200
200
200
200

160
160
160
160
-

**Note: Ratings for Ordinary Water Works Restraint Applications with Transitory Surges Only

STOP-LOOK :

Piping system Installation and hydrostatic testing shall be in accordance with AWWA C600 and AWWA C651.
TUF Grip 4 to 12 restraints shall meet the requirements of ASTM F1674, current revision.
*Tyler Union Waterworks Contact Information*
Tyler: 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
th
Anniston: 1501 W 17 St. Anniston, AL 36201 (800) 226-7601
Corona: 1001 El Camino Ave. Corona, CA 92879 (866) 527-8471

89

Assembly Steps Series 2000S TLP Split For PVC Pipe


Steps:1and 2

1.
2.
3.
4.

Insure the beveled pipe end to be joined and mechanical joint socket are clean and free of debris.
Lubricate the pipe end and exterior plus the inside surface of gasket with joint lubricant that meets the
requirements of AWWA C111. Now place the MJ gasket over the plain beveled end of the pipe with the narrow edge
of the tapered gasket toward the beveled end of the pipe to be restrained.
Fully insert the pipe end into the MJ socket pipe landing. Keeping the pipe straight, slide/push the gasket firmly and
evenly into the MJ socket recess. **NOTE: For IPS diameter pipe use of an MJ transition gasket is required.
Place the two halves of the red TUF Grip around the pipe with the compression lip extension toward the MJ socket.
Join the two restraint halves together with two T-Head bolts. Use only T-Head bolts, nuts, and gasket that meet
AWWA C111 requirements.
Steps:5

5.

6.

7.
8.

9.

Step:3 and 4

Steps:6 and 7

Steps:8 and 9

With the two T-Head bolts inserted through the restraint, push the TUF Grip lip extension evenly against the thick
side of the MJ gasket. With the TUF grip restraint against the gasket, the remaining T-Head bolts are inserted with
the T-Head against the back of the MJ fitting bolt flange. Install two additional T-Head bolts with nuts and hand
tighten to secure the restraint to the fitting.
With the restraint secured to the fitting, remove the original assembly T-Head bolts and reinsert with the T-Head
against the back of the MJ fitting bolt flange. Making sure the TUF Grip is centered around the pipes wall, hand
tighten all the remaining T-Head bolts and nuts. If joint deflection is needed, only deflect the pipe in joint after hand
tightening of all nuts is completed. Maximum joint deflection is 3 when pipe and fitting dimensions are nominal.
Using a wrench, tighten the nuts on the T-Head bolts a few turns at a time in an alternating or star pattern. Maintain
equal spacing between the TUF Grip bolt flange and the bolt flange of the MJ socket as the gasket is compressed.
The T-Head bolt and nut torque requirement is 75-90 ft.-lbs. for 4-12 restraints. DO NOT OVER-TORQUE!
Hand-tighten the torque limiting nut attached to the TUF Grip wedge assemblies in a clockwise direction with an
alternating or star pattern until all gripping wedges are in contact with the pipe wall. Rotational direction of torque
nut is indicated by a recessed arrow on the face of the nut. With a wrench, continue to tighten each torque nut
turn in an alternating or star pattern until all torque limiting nuts twist off. NEVER tighten a torque limiting nut more
than turn without turning the remaining torque nuts an equal amount! **NOTE: For IPS applications, ensure step
7 is complete before engaging the wedges. Failure to comply will result in excessive pipe wall deflection and torque
nuts will not twist off as designed.
When all torque limiting nuts twist off, the mechanical joint and restraint assembly are complete.
*Tyler Union Waterworks Contact Information*
Tyler: 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
th
Anniston: 1501 W 17 St. Anniston, AL 36201 (800) 226-7601
Corona: 1001 El Camino Ave. Corona, CA 92879 (866) 527-8471
90

FOR:

AWWAC900 (4 12) and AWWAC905 (14 36) PVC Pipe to Pipe Restrainer (Bell to Pipe Spigot)

FEATURES and ADVANTAGES:

Available in sizes 4 through 36 (Clamps for IPS PVC pipe available in 4 12 only)
Restraints rated at the listed pressure on the PVC pipe with a 2:1 safety factor
Full 360 contact, No pipe distortion or point loading
To ease installation, restraints and pipe can be assembled outside the trench
Connecting rods, hex nuts, T-head bolts consist of low alloy high strength steel and comply with
applicable requirements of ANSI/AWWA C111/A21.11
Clamping bolts are SAE Grade 5 and comply with applicable requirements of ANSI/AWWA C111/A21.11
For easy identification, IPS pipe diameter clamps are GREY and DI pipe diameter clamps are BLACK
SAMPLE SPECIFICATIONS:

All sizes of clamps are made of high strength grade 65-45-12 ductile iron in accordance with the
requirements and specifications of ASTM A536. Clamps provide full 360 degree contact with the PVC
pipe and internal serrations are machined to exact tolerances. Restrainers approved per applicable
requirements of ASTM F1674, current revisions apply. The 3000PP kits include, 1) 2 each 3000C
restrainers, 2) hex head bolts and hex nuts for restrainer assembly, and 3) threaded restrainer
connecting rods with hex nuts.
4 to 12 Assembly

Nominal
Size

Series 3000PP For PVC Pipe


w/Ductile Pipe O.D.

Pipe O.D.
Part Number
4
4.80
462422
6
6.90
462439
8
9.05
462446
10
11.10
462453
12
13.20
462460
14
15.30
488033
16
17.40
488040
18
19.50
488057
20
21.60
488064
24
25.80
488071
30
32.00
498599
36
38.30
498605
*Note: Approximate dimension

14 to 36 Assembly

Series 3000PP For PVC Pipe


w/IPS Pipe O.D.
Pipe O.D.
4.50
6.63
8.63
10.75
12.75
N/A
N/A
N/A
N/A
N/A
N/A
N/A

Part Number
462477
462484
462491
462507
462514
N/A
N/A
N/A
N/A
N/A
N/A
N/A

*A

9.12
11.12
14.74
16.81
19.45
22.54
24.66
26.64
28.76
33.98
40.90
48.00

1.12
1.12
1.25
1.38
1.38
4.00
4.00
5.06
5.06
5.20
10.00
10.00

C
MAX.
Qty.
12.0
13.0
15.0
16.0
18.0
24.0
28.0
28.0
34.0
34.0
34.0
34.0

Restraint Rods
Connecting
Qty.
2
2
2
4
4
6
6
8
8
12
12
12

Size
3/4 X 17
3/4 X 17
3/4 X 17
3/4 X 24
3/4 X 24
3/4 X 30
3/4 X 30
3/4 X 30
3/4 X 36
3/4 X 36
1 X 40
1 X 40

Quantity, Sizing and Torque


For Clamp Assembly Bolts
Qty
4
4
4
4
4
8
8
8
8
8
16
16

Size
5/8 X 3.5
5/8 X 3.5
3/4 X 5
7/8 X 5
7/8 X 5
7/8 X 6.5
7/8 X 6.5
1X8
1-1/8 X 8.5
1-1/8 X 8.5
1-1/8 X 8.5
1-1/8 X 8.5

Torq
100
100
150
150
150
150
150
175
200
225
250
250

~WT
LBS.
15
19
31
51
55
138
148
207
265
407
605
670

91
Tyler Union Waterworks Contact Information
Tyler: 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
Elmira: 1021 East Water Elmira, NY 14902
Anniston: 1501 W 17th St. Anniston, AL 36201 (800) 226-7601
New Lenox: 2200 West Haven New Lenox, IL 60451
Corona: 1001 El Camino Ave. Corona, CA 92879 (866) 527-8471
Portland: 6204 N. Marine Dr. Portland, OR 97203
www.tylerunion.com

Installation Instructions for Sizes 4 36 Series 3000PP:


Figure 1

Figure 2

Figure 3

Figure 4

Step (1): Assemble pipe per Figure 1 making sure the spigot end of the pipe is fully seated in the bell end of the pipe.

Step (2): Assemble first restrainer on the bell end of the pipe joint and using one of the connecting rods (included) as a guide, mark
the location for the spigot restrainer per Figure 2.

Step (3): Assemble the spigot restrainer leaving sufficient threads on each end of the connecting rod to fully install washer and fully
engage nut per Figure 3. Tighten the restrainer clamp assembly bolts on each side evenly to the recommended torque
maintaining even gaps between the clamp pads.

Step (4): Connect both restrainers per Figure 4 utilizing the threaded restrainer connecting rods provided. Place a flat washer over
onto connecting rods and against the restrainer ear. Install hex nuts on the connecting rods and hand tighten all hex nuts
to hand tight plus one full turn. Do not over tighten retaining hex nuts. Use additional hex nuts (not included) on the inside
of restrainer ears if joint is expected to contract.

The hex head bolt and hex nut *torque recommended for assembly of the 3000C restrainers is as provided
NOTE: For best results use the lower end of the recommended torque range for DR 41 and DR 51 PVC pipe
*4 6 100 ft. lbs. | 8 12 150 ft. lbs. | 14 16 150 200 ft. lbs.
18 175 225 ft. lbs. | 20 200 250 ft. lbs. | 24 225 275 ft. lbs. | 30 36 - 250 300 ft. lbs.

92

Tyler Union Waterworks Contact Information


Tyler: 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
Elmira: 1021 East Water Elmira, NY 14902
Anniston: 1501 W 17th St. Anniston, AL 36201 (800) 226-7601
New Lenox: 2200 West Haven New Lenox, IL 60451
Corona: 1001 El Camino Ave. Corona, CA 92879 (866) 527-8471
Portland: 6204 N. Marine Dr. Portland, OR 97203
www.tylerunion.com

FOR:

PVC Pipe Stop for AWWAC900 (4 12) and AWWAC905 (14 16) PVC Pipe
Note: IPS PVC Pipe Stop available for sizes 4 12

USE:

Improper installation such as over-insertion of a PVC pipe to pipe joint can cause damage to pipe bells, reduction in joint
deflection, and cause leaks. The 3000PS when properly installed will allow joint to be installed and operate to design
specifications.

FEATURES and ADVANTAGES:


Available in sizes 4 through 16 (Ring Support Clamps for IPS PVC Pipe available in 4 12 only)
Full 360 contact, No pipe distortion or Point loading
To ease installation, ring support clamp can be assembled on the piping outside the trench
Clamping bolts comply with applicable ANSI/AWWA C111/A21.11 requirements
For easy identification, IPS pipe diameter clamps are GREY and DI pipe diameter clamps are BLACK

SAMPLE SPECIFICATIONS:
Ring support clamps are made of high strength grade 65-45-12 ductile iron in accordance with the requirements and
specifications of ASTM A536. Clamps provide full 360 degree contact with the PVC pipe and internal serrations are
machined to exact tolerances. Serrated clamps shall be used to grip the pipe and be capable of being installed bidirectional. The rubber bell stop ring is NSF-61 approved.
4 to 12 Assembly

Nominal
Size
4
6
8
10
12
14
16

Series 3000PS For PVC Pipe


w/Ductile Pipe O.D.

Series 3000PS For PVC Pipe


w/IPS Pipe O.D.

Pipe O.D.
4.80
6.90
9.05
11.10
13.20
15.30
17.40

Part Number
Pipe O.D.
Part Number
538981
4.50
CALL
538998
6.63
CALL
539001
8.63
CALL
538967
10.75
CALL
538974
12.75
CALL
539018
N/A
N/A
539025
N/A
N/A
*Note: Approximate dimension
**Note: Red Dimensions are for IPS Pipe Bell Stop Rings.

Figure 1

Figure 2

14 to 16 Assembly

*A

9.12
11.12
14.74
16.81
19.45
22.54
24.66

1.12
1.12
1.25
1.38
1.38
4.00
4.00

**D

Quantity, Sizing and Torque For


Clamp Assembly Bolts

DIOD/IPS
Qty
Size
Torque (ft.-lbs.)
2.34 /2.38
2.
5/8 X 3.5
100
2.34 /2.37
2
5/8 X 3.5
100
2.47 /2.52
2
3/4 X 5
150
2.60 /2.64
2
7/8 X 5
150
2.60 /2.66
2
7/8 X 5
150
5.22 /N/A
4
7/8 X 6.5
150
5.22 /N/A
4
7/8 X 6.5
150
**Note: IPS dimensions for pipe bell stop rings are in red

Figure 3

Clamp
Weight

Kit
Weight

4.5 lbs.
6.5 lbs.
10.0 lbs.
18.0 lbs.
21.0 lbs.
43.5 lbs.
46.0 lbs.

5.5 lbs.
7.5 lbs.
12.0 lbs.
20.0 lbs.
22.5 lbs.
45.0 lbs.
48.0 lbs.

Figure 4

Step (1): Lube the inside diameter of the Bell Stop Ring and slide the ring onto the Plain end of the PVC pipe. The angled side of the gasket
must face away from the end of the pipe to be assembled per figure 1.
Step (2): Align the Bell Stop Ring with the pipe manufacturers reference line per figure 2. If the pipe has been cut or the line is not visible,
mark a line at the pipe manufacturers recommended distance.
Step (3): Assemble the 3000C Ring Support Clamp at the end of the Bell Stop Ring per figure 3. Tighten the ring support Clamping Bolts on each
side evenly, maintaining equal spacing between the clamp ring support pads on both sides. (4 6 100 ft. lbs., 8 12 150 ft. lbs.)
Step (4): Complete PVC pipe joint assembly per manufacturers assembly instructions.

Tyler Union Waterworks Contact Information


Tyler: 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
Anniston: 1501 W 17th St. Anniston, AL 36201 (800) 226-7601
Corona: 1001 El Camino Ave. Corona, CA 92879 (866) 527-8471
www.tylerunion.com

93

FOR:

Restraining AWWAC900 (4 12) and AWWAC905 (*14 36) PVC pipe to mechanical joint fittings
Note: IPS 3000MJ available for sizes 4 12
Note: *4 16 provided in boxed kits. Sizes larger than 16 will be provided with accessories kitted
separate from the restraint and gland.

FEATURES and ADVANTAGES:


Available in sizes 4 through 36 (Clamps for IPS PVC pipe available in 4 12 only)
Restraints rated at the listed pressure on the PVC pipe with a 2:1 safety factor
Full 360 contact, no pipe distortion or point loading
Connecting rods, hex nuts, T-head bolts consist of low alloy high strength steel and comply with applicable
requirements of ANSI/AWWA C111/A21.11
Clamping bolts are SAE Grade 5 and comply with applicable requirements of ANSI/AWWA C111/A21.11
For easy identification, IPS pipe diameter clamps are GREY and DI pipe diameter clamps are BLACK

SAMPLE SPECIFICATIONS:
All sizes of clamps are made of high strength grade 65-45-12 ductile iron in accordance with the requirements
and specifications of ASTM A536. Clamps provide full 360 degree contact with the PVC pipe and internal
serrations are machined to exact tolerances. Restrainers approved per applicable requirements of ASTM F1674,
current revisions apply. The 3000MJ kits include, 1) 1 each 3000C restrainer, 2) hex head clamping bolts and
nuts for restrainer assembly, 3) threaded restrainer connecting rods and hex nuts, 4) 1 each AWWA C153
mechanical joint gland, 5) 1 each NSF approved MJ gasket, and 6) all T-head bolts and hex nuts for gland
assembly.
4 to 12 Assembly

Nominal
Size

Series 3000MJ For PVC Pipe


w/Ductile Pipe O.D.

Pipe O.D.
DIOD Part No.
4
4.80
462576
6
6.90
462583
8
9.05
462590
10
11.10
462606
12
13.20
462613
14
15.30
CALL
16
17.40
CALL
18
19.50
CALL
20
21.60
CALL
24
25.80
CALL
30
32.00
CALL
36
38.30
CALL
*Note: Approximate dimension

14 to 36 Assembly

Series 3000MJ For PVC Pipe


w/IPS Pipe O.D.
Pipe O.D.
4.50
6.63
8.63
10.75
12.75
N/A
N/A
N/A
N/A
N/A
N/A
N/A

IPS Part No.


512899
512905
512912
512875
512882
N/A
N/A
N/A
N/A
N/A
N/A
N/A

*A

9.12
11.12
14.74
16.81
19.45
22.54
24.66
26.64
28.76
33.98
40.90
48.00

1.12
1.12
1.25
1.38
1.38
4.00
4.00
5.06
5.06
5.20
10.00
10.00

C
MAX.
Qty.
6.00
6.00
6.00
6.00
6.00
15.00
15.00
15.00
22.00
22.00
22.00
22.00

Restraint Rods
Connecting
Qty.
2
2
2
4
4
6
6
8
8
12
12
12

Size
3/4 X 7
3/4 X 7
3/4 X 7
3/4 X 7
3/4 X 7
3/4 X 17
3/4 X 17
3/4 X 17
3/4 X 24
3/4 X 24
1 X 24
1 X 24

Quantity, Sizing and Torque


For Clamp Assembly Bolts
Qty
2
2
2
2
2
4
4
4
4
4
8
8

Size
5/8 X 3.5
5/8 X 3.5
3/4 X 5
7/8 X 5
7/8 X 5
7/8 X 6.5
7/8 X 6.5
1X8
1-1/8 X 8.5
1-1/8 X 8.5
1-1/8 X 8.5
1-1/8 X 8.5

Kit
(lbs.)

Torq
100
100
150
150
150
150
150
175
200
225
250
250
94

Tyler Union Waterworks Contact Information


Tyler: 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
Anniston: 1501 W 17th St. Anniston, AL 36201 (800) 226-7601
Corona: 1001 El Camino Ave. Corona, CA 92879 (866) 527-8471
www.tylerunion.com

Elmira: 1021 East Water Elmira, NY 14902


New Lenox: 2200 West Haven New Lenox, IL 60451
Portland: 6204 N. Marine Dr. Portland, OR 97203

Installation Instructions for Sizes 4 12 Series 3000MJ:


Figure 1

Figure 2

Figure 3

Figure 4

Figure 5

Step (1): Assemble the mechanical joint, installing gasket, gland, and T-head bolts per AWWA C600 standard, leave out the T-head

bolt corresponding to the restrainer ears per Figure 1.


Step (2): Per Figure 2, use a 7 T-head bolt (included) as a guide and mark the location on the pipe where the restrainer will be

assembled.
Step (3): Assemble restrainer per Figure 3, leaving sufficient threads on the end of the T-head bolt to fully engage nut.
Step (4): Tighten the restrainer clamp assembly bolts on each side evenly to the recommended torque maintaining even gaps

between the clamp pads. (4 - 6 100 ft lbs., 8 12 150 ft. lbs.)


Step (5): Connect restrainer to fitting per Figure 5. Insert the 7 T-head bolt (bolt and 2 hex nuts provided) through the bolt flange

installing a hex nut between the gland and restrainer. Tighten the hex nut up to gland per AWWA C600 standard. Tighten
the second hex nut up to the restrainer as show in Figure 5. Use additional hex nuts (not included) on the inside of the
restrainer ear if joint is expected to contract.

Installation Instructions for Sizes 14 36 Series 3000MJ:


Figure 1

Figure 2

Figure 3

Figure 4

Step (1): Assemble the mechanical joint, installing gasket, gland, and T-head bolts per AWWA C600 standard, leave out the T-head

bolt corresponding to the restrainer ears per Figure 1.


Step (2): Per Figure 2, use a connecting rod (included) as a guide and mark the location on the pipe where the restrainer will be

assembled.
Step (3): Assemble restrainer per Figure 3, leaving sufficient threads on the end of the connecting rod to fully install washer and fully

engage hex nut. Tighten the restrainer clamp assembly bolts on each side evenly to the recommended torque maintaining
even gaps between the clamp pads. (14 16 150 200 ft lbs., 18 - 175 - 225 ft. lbs., 20 - 200 - 250 ft. lbs., 24 - 225 275 ft. lbs., 30 250 - 300 ft. lbs., and 36 - 250 - 300 ft. lbs.)
Step (4): Connect restrainer to fitting per Figure 4. Inserting the rods through the restrainer ears(rod and 3 hex nuts provided for

each ear), gland, and fitting bolt hole. Install one hex nut behind fitting bell, one hex nut against the gland and one hex nut
behind the restrainer ear against the washer. Tighten hex nut up to gland per AWWA C600 standard. Use additional hex
nuts (not included) on the inside of the restrainer ear if joint is expected to contract.
95

Tyler Union Waterworks Contact Information


Tyler: 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
Anniston: 1501 W 17th St. Anniston, AL 36201 (800) 226-7601
Corona: 1001 El Camino Ave. Corona, CA 92879 (866) 527-8471
www.tylerunion.com

Elmira: 1021 East Water Elmira, NY 14902


New Lenox: 2200 West Haven New Lenox, IL 60451
Portland: 6204 N. Marine Dr. Portland, OR 97203

2013/2014 - Certificate of Compliance Waterworks Division


Tyler Union Waterworks manufactures and distributes ductile iron water main fittings with accessories. Tyler Union 2 inch through *64
inch fittings are cast with tested and traceable ASTM A536 compliant ductile iron that is designed for use with and conforms to the applicable terms
and requirements (including markings) of ANSI/AWWA C153/A21.53, ANSI/AWWA C151/A21.51, ANSI/AWWA C115/A21.15, ANSI/AWWA
C111/A21.11, ANSI/AWWA C116/A21.16, ANSI/AWWA C110/A21.10, and ANSI/AWWA C104/A21.4, Tyler Union Waterworks mechanical and push
on joint fittings are compatible with PVC pipe conforming to AWWA C900-C905. Current revisions apply for each noted standard. Tyler Union offers
a full line of ANSI/AWWA Imported products as well as a full line of Domestic products made in the U.S.A. If you have a product preference, you
must specify upon order placement. *Note: For certification of 54 to 64 fittings, contact your Tyler Union Waterworks representative.
**Tyler Union Waterworks ANSI/AWWA C153/A21.53 ductile iron Mechanical and Push-On joint fittings 2 inch through 24 inch shall
be rated for 350 PSI working pressure and a surge allowance of 100 PSI. Mechanical and Push-On joint fittings 30 inch through 48 inch shall be
rated for 250 PSI working pressure and a surge allowance of 100 PSI.
**Tyler Union Waterworks ANSI/AWWA C110/A21.10 ductile iron Mechanical joint fittings in 2 inch through 24 inch shall be rated for
350 PSI working pressure and a surge allowance of 100 PSI. Mechanical joint fittings 30 inch through 48 inch shall be rated for 250 PSI working
pressure and a surge allowance of 100 PSI.
**Tyler Union Waterworks ANSI/AWWA C110/A21.10 and ANSI/AWWA C153/A21.53 ductile iron Flanged joint fittings in 2 inch through
48 inch shall be rated for 250 PSI working pressure and a surge allowance of 100 PSI. Flange fittings 24 inches (610 millimeters) and smaller may be
rated for 350 PSI (2,413 kPa) working pressure with the use of special gaskets. Per Section A.3 of ANSI/AWWA C110/A21.10 ductile iron Flange joint
fittings are not recommended for underground installation due to the rigid design of the fitting flange and joint.
**Note Exceptions:

Mechanical and Push-On joint fittings with flanged branches are rated for working pressure of 250
PSI. Flange fittings 24 inches and smaller may be rated for 350 PSI working pressure with the use of
special flange gaskets. For 350 PSI flange joint applications we recommend the use of annular ring
type gasket or comparable. AWWA C153 MJ and Push on joint wyes larger than 12 are not
pressure; contact Tyler Union for the allowable pressure ratings for 14 and larger wyes.

Tyler Union Waterworks ANSI/AWWA C110/A21.10 and ANSI/AWWA C153/A21.53 ductile iron Mechanical joint fittings and
ANSI/AWWA C153/A21.53-06 (manufacturers standards) Push-On joint fittings when installed per AWWA C600/651 are rated for a *maximum 5
degrees of deflection for 3 inch through 12 inch fittings and a *maximum 3 degrees of deflection for 14 inch through 48 inch fittings.
*Note : The total joint deflection is determined by the O.D. of the pipe and the I.D. of the fitting. When both the pipe and the
fitting are at nominal; the joint deflection will be approximately 50% of the maximum listed.
Tyler Union Waterworks coated and/or cement lined Potable water ductile iron fittings meet all the applicable terms and requirements of
ANSI/AWWA C116/A21.16, ANSI/AWWA C104/A21.4, and AWWA C550. Potable water products manufactured and distributed by Tyler Union
Waterworks are National Sanitation Foundation NSF 61, NSF-372, and Annex G compliant. Current revisions apply for each noted standard.
Tyler Union Waterworks Valve and Service boxes are produced in accordance with and meet all applicable terms and provisions of
ASTM-A48. Cast iron Service and Valve box products when properly selected and installed per the guidelines provided by AWWA M44 (Manual of
Water Supply Practices) will provide accessibility for testing and maintenance of a water supply system and will meet the Wheel load designation as
provided by the American Association of State Highway Transportation Officials (AASHTO).
Tyler Union Waterworks Mechanical joint fittings, Glands, T-Head bolts, and Nuts are produced in accordance with and meet all applicable
terms and provisions of ANSI/AWWA C111/A21.11. Tyler Union Mechanical and Push-On joint gaskets are produced in accordance with and meet
all applicable terms and provisions of ANSI/AWWA C111/A21.11. Tyler Union manufacturers standard design Mechanical and Push-On joint
Transition gaskets are produced in accordance with and will meet all applicable terms and provisions of ANSI/AWWA C111/A21.11.
All applicable tests have been performed and results maintained with all materials supplied being of the same quality, manufacture, and
make as those tested.
Sincerely,

Project Name:

Roger Dunning
Roger Dunning
Technical Support Manager
Tyler Union Waterworks
Email: roger.dunning@tylerunion.com
Tel.: (800) 527-8478

Project Material:
Product Supplier:
Contractor:
File:

COC TU Products

*Tyler Union Waterworks Contact Information*


Tyler: 11910 CR 492 Tyler, Texas 75706 (800) 527-8478
th
Anniston: 1501 W 17 St. Anniston, AL 36201 (800) 226-7601
Corona: 1001 El Camino Ave. Corona, CA 92879 (866) 527-8471
www.tylerunion.com
This document is void if modified in any manner other than the addition of project information

98

McWane, Inc. Terms and Conditions of Sale

1.
ENTIRE AGREEMENT. McWane, Inc. and its divisions and subsidiaries (the Seller) agrees to sell the goods
covered herein (Goods) to Buyer on the following terms and conditions of sale (the Terms and Conditions) which
supersede any other or inconsistent terms of Buyer. The Terms and Conditions and the order or other contract
documents to which they are attached constitute the entire agreement between the parties with respect to the Goods (the
Agreement). All references by Seller to Buyers specifications and similar requirements are only to describe the Goods
and work covered hereby and no warranties or other terms will have any force or effect. Neither this Agreement, nor any
modification, amendment or waiver to it, nor any cancellation, change or return of any order under it, will be binding on
Seller until agreed in writing by Sellers authorized representative. No representation, promise or term not set forth herein
has been or may be relied upon by Buyer, and any terms not contained in this Agreement are expressly objected to and
rejected. Acceptance of orders, whether oral or written, and/or delivery by Buyer is based on the express condition that
Buyer agrees to all of these Terms and Conditions.
2.
QUOTATIONS. Where this Agreement is used by Seller to place a bid, the quotation stated herein is for
prompt acceptance and Seller may change and/or withdraw without notice. Prompt acceptance by Buyer of all quotations
is a material term of the bid and any subsequent agreement. In cases where freight allowance is included in the quotation,
Buyer is liable for any rate increase and/or additional expense over the calculated allowance resulting from compliance with
Buyers shipping instructions.
3. DELIVERY. All prices are EXW (Ex-Works)(per Incoterms 2010), unless otherwise specified by Seller in writing. All
shipping dates are approximate, and any time period indicated for a shipment will not commence until receipt at
Sellers plant of complete manufacturing, shipping, and credit information. Acceptance of shipment by designated
shipper, allocation of Goods to Buyer at premises other than Sellers, delivery to Buyers representative or designee or
mailing of an invoice to Buyer, whichever first occurs, will constitute tender of delivery and title will pass to Buyer, subject
to Sellers right of stoppage in transit and to any interest of Seller reserved to secure Buyers payment or performance,
irrespective of any freight allowance or prepayment of freight. In the case of Goods held subject to Buyers instructions,
Goods for which Buyer has failed to supply shipping instructions, or in any case where Seller, in its sole discretion,
determines that any part of the Goods should be held for Buyers account, Seller may invoice for the Goods and Buyer
agrees to make payment at the maturity of the invoice rendered. Goods invoiced and held at any location for whatever
reason will be at Buyers risk and Seller may charge for (but is not obligated to carry) insurance, storage and other
expenses incident to such delay at their prevailing rates. Partial deliveries shall be accepted by Buyer and paid for at
Agreement prices and terms. When Buyer has declared or manifested an intention not to accept delivery, no tender shall be
necessary but Seller may, at its option, give notice in writing to Buyer that Seller is ready and willing to deliver and such
notice shall constitute a valid tender of delivery.
Buyer must report any shortages in shipments within three (3) days of
receipt of the initial shipment.
4.
LOSS OR DAMAGE IN TRANSIT. Buyer may not make any deduction from any payment due hereunder by
reason of loss or damage to Goods in transit. Upon Buyers written request, Seller, in its sole discretion, may agree as a
service to Buyer to process Buyers claim against the carrier for any loss or damage in transit, provided that Seller
receives such claim within five (5) days of the delivery of the Goods. Any such claims must be accompanied by a delivery
receipt, signed by carriers agent at time of delivery, on which receipt the loss or damage has been noted, or such claims
will be waived.
5.
TERMS OF PAYMENT. Terms are stated on Sellers order or invoice document. Seller may make partial
shipments and payment for that portion shall be due as provided on Sellers order or invoice document based on time of
shipment. If, at any time or for any reason, Seller has cause to question Buyers ability to perform, Seller may
demand such assurances of Buyers performance as Seller deems necessary in its discretion, including payment in
advance for all shipments. If Buyer fails within ten (10) days of Sellers demand to provide Seller with such assurance,
Seller may suspend its performance, cancel any order then outstanding, receive reimbursement for its reasonable and
proper cancellation charges and collect, without limitation, any sums due and owing, its reasonable cancellation
charges and all damages resulting from Buyers default.
In t he e v e n t of Buyers bankruptcy or insolvency, or in
the event of any proceeding brought against Buyer, voluntarily or involuntarily, under bankruptcy or any insolvency laws,
Seller may cancel any order then outstanding at any time and receive reimbursement for its reasonable and proper
cancellation charges. If Buyer fails to make payment for Goods when due, Buyers account will be deemed delinquent and
Buyer will be liable to Seller for a service charge of eighteen percent (18%) per annum or the maximum allowed by law,
whichever is greater, on any unpaid amount; provided that, in addition to the foregoing, Seller may also suspend its
performance, cancel any order then outstanding, receive reimbursement for its reasonable and proper cancellation charges
and to collect, without limitation, any sums due and owing, its reasonable cancellation charges and all damages resulting
from Buyers default. Buyer will be liable to Seller for all costs and expenses of collection, including court costs and
reasonable attorneys fees.

6/17/2013

McWane, Inc. Terms and Conditions of Sale


6.
CANCELLATION, CHANGES AND RETURNS. In the event of a proper cancellation, change or return request from
Buyer under this Agreement, Seller may, at its option: (A) charge Buyer for any costs Seller incurred prior to or as a
result of such cancellation, change or return; (B) revise its prices and delivery dates to reflect such change; and/or (C)
accept returned Goods for credit if, in Sellers sole discretion, it finds such Goods to be standard stock and in good
condition. The credit will be, in Sellers sole discretion, either the invoice price less a percentage to be determined by the
Seller or the scrap value of the Goods, along with shipping and handling charges to be determined by Seller. All returned
Goods must be securely packed by Buyer to ensure that the returned material is not damaged during shipment.
7. DELAY IN OR PREVENTION OF PERFORMANCE. Seller will not be liable for any expense, loss or damage resulting
from delay in delivery or prevention of performance caused by any event beyond Sellers reasonable control (Force
Majeure), including without limitation: fire; flood; storm; act of God; strike, labor dispute or labor shortage; lack of or inability
to obtain materials, fuels, supplies or equipment; civil unrest or riot; accident; transportation delay or shortage; act or
failure to act of any government or of Buyer; or any other cause whatsoever, provided that such cause is beyond Sellers
reasonable control. Seller will have such additional time for performance as may be reasonably necessary under the
circumstances and may adjust the price to reflect increases occasioned by Force Majeure. Buyers acceptance of any
Goods will constitute Buyers waiver of any claim for damages on account of any delay in delivery of such Goods. If
delivery is delayed or interrupted by Force Majeure, Seller may store the Goods at Buyers expense and risk and charge
Buyer a reasonable storage rate. If Seller is delayed because it is awaiting Buyers approval or acceptance of designs,
drawings, prints, engineering or technical data, or is awaiting Buyers approval or acceptance of Goods, Seller will be
entitled to an adjustment in price commensurate with any increase in its cost of production and any other losses and
expenses incurred by Seller attributable to such delays.
8.
DEFERRED DELIVERY. If Buyer requests a deferred delivery and Seller approves in writing, Seller may charge
Buyer for the completed portion of this Agreement and warehouse all completed Goods at Buyers expense and risk of
loss. As to any uncompleted portion of this Agreement, Seller may, at its option, cancel said uncompleted portion in
accordance with Paragraph 6 above or revise its prices and delivery schedules on the portion not completed to reflect its
increased costs and expenses attributable to the delay.
9.
WARRANTY AND BUYERS REMEDIES. Seller warrants that the Goods will be of the kind described in this
Agreement and free from defects in material and workmanship under conditions of normal use. Seller reserves the right to
make any modifications required by production conditions to the information set forth in Sellers catalogues and
advertising literature. Seller will not be liable or responsible, however, for (A) any defects attributed to normal wear and
tear, erosion or corrosion, improper storage, use or maintenance or use of the Goods with incompatible products, or (B)
defects in any portion or part of the Goods manufactured by others. If (B) above is applicable, Seller will, as an
accommodation to Buyer, assign to Buyer any warranties given to it by any such other manufacturers; provided, however,
that the foregoing will not extend Sellers warranty to any accessory products unless otherwise agreed to in writing
by Seller.
All warranties provided herein are void if the Goods are modified or used in conjunction with products or
accessories not manufactured or approved by Seller or which are incompatible with the Goods. Any claim by Buyer with
reference to the Goods for any cause will be deemed waived by Buyer unless submitted to Seller in writing within ten (10)
days from the date Buyer discovered, or should have discovered, any claimed breach. Buyer will give Seller an opportunity
to investigate. Provided that Seller is furnished prompt notice by Buyer of any defect and an opportunity to inspect the
alleged defect as provided herein, Seller will, at its option and in its sole discretion either: (i) repair the defective or nonconforming Goods; (ii) replace the nonconforming Goods, or part thereof, which are sent to Seller by Buyer within sixty
(60) days after receipt of the Goods at Buyers plant or storage facilities; or (iii) if Seller is unable or chooses not to repair
or replace, return the purchase price that has been paid and cancel any obligation to pay unpaid portions of the purchase
price of nonconforming Goods. In no event will any obligation to pay or refund exceed the purchase price actually paid.
Repair and/or replacement as provided above will be shipped EXW (Ex- Works)(per Incoterms 2010) unless otherwise
agreed in writing by Seller. Buyer will prepay all transportation charges for the return of the Goods or part thereof to Seller,
unless otherwise agreed in writing by Seller. Seller will not be responsible for any labor, removal or installation charges that
may result from the above-described repair and/or replacement of any Goods. This warranty does not cover failure of any
part or parts manufactured by others, failure of any part or parts from external forces, including without limitation
corrosive soils, earthquake, installation, vandalism, vehicular or other impact, application of excessive torque to the
operating mechanism, frost heave or other Force Majeure. Buyers exclusive remedy and Sellers sole liability for any
loss, damage, injury or expense of any kind arising from the manufacture, delivery, sale, installation, use or shipment of the
Goods and whether based on contract, warranty, tort or any other basis of recovery whatsoever, will be, at Sellers
election, the remedies described above. The foregoing is intended as a complete allocation of risks between the parties
and Buyer understands that it will not be able to recover consequential damages even though it may suffer such damages
in substantial amounts. Because this Agreement and the price paid reflect such allocation, this limitation will not have
failed of its essential purpose even if it operates to bar recovery for such consequential damages.

6/17/2013

McWane, Inc. Terms and Conditions of Sale


10. PATENTS. If any claim is made against Buyer based on a claim that any of the Goods constitute an infringement of
any U.S. Letter Patent, Buyer will notify Seller immediately. Seller may, with Buyers assistance, if required, but at Sellers
expense, conduct settlement negotiations or the defense of any litigation. If any of the Goods are held to infringe any U.S.
Letter Patent, and their use is enjoined or, if as a result of a settlement, Seller deems their continued use unadvisable and
provided that Buyer has given Seller the immediate notice required above and has used the Goods only in accordance with
the provisions of this Agreement and has not altered or changed them in any material way, Seller will, at its option and
expense, procure for Buyer the right to continue using the Goods, modify the Goods so that they become non-infringing,
replace the Goods with non-infringing Goods of substantially equal quality, or replace the Goods and refund the
purchase price, less reasonable depreciation. The foregoing states Sellers entire liability for patent infringement.
11. LIMITATION OF LIABILITY.
THE WARRANTIES IN PARAGRAPHS 9 AND 10 ARE EXCLUSIVE AND
IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED BY LAW OR STATUTE OR ARISING FROM
TRADE USAGE OR COURSE OF DEALING. THERE IS NO IMPLIED WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT, WHETHER AS A RESULT OF BREACH OF CONTRACT,
WARRANTY, TORT (INCLUDING NEGLIGENCE) OR STRICT LIABILITY, WILL SELLER BE LIABLE FOR ANY PUNITIVE,
SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION LOSS OF PROFIT,
LOSS OF USE OF THE GOODS OR OTHER PROPERTY OR EQUIPMENT, DAMAGE TO OTHER PROPERTY, COST
OF CAPITAL, COST OF SUBSTITUTE GOODS, DOWNTIME, OR THE CLAIMS OF BUYERS CUSTOMERS FOR ANY
OF THE AFORESAID DAMAGES. SELLER W ILL NOT BE LIABLE AND BUYER AGREES TO INDEMNIFY SELLER
FOR ALL PERSONAL INJURY, PROPERTY DAMAGE OR OTHER LIABILITY RESULTING IN WHOLE OR IN PART
FROM BUYERS NEGLIGENCE. NO CLAIMS OF ANY NATURE, WHETHER BASED ON CONTRACT, TORT, STRICT
LIABILITY OR OTHERWISE MAY BE BROUGHT AGAINST SELLER MORE THAN TWENTY-FOUR (24) MONTHS AFTER
DELIVERY OF THE GOODS TO BUYER.
In any contract by Buyer for resale of Goods Buyer will effectively disclaim, as against Seller, any implied warranty of
merchantability and all liability for property damage or personal injury resulting from handling, possession or use of Goods,
and shall exclude, as against Seller, any liability for special or consequential damages.
12. CONTROLLING LAW AND CONSENT TO VENUE.
This Agreement and all rights and obligations
hereunder will be governed by, and construed in accordance with, the laws of the State of Alabama, U.S.A., without regard
to its conflicts of laws provisions. The United Nations Convention on Contracts for the International Sale of Goods shall
not apply to this Agreement. Except when the dispute is arbitrated, the parties irrevocably agree that the exclusive
venue for all disputes between the parties will be the state and federal courts of Alabama, U.S.A., to which jurisdiction Buyer
hereby irrevocably submits. Buyer waives any objection or defense that Buyer is not personally subject to jurisdiction of the
state and federal courts of Alabama, U.S.A.; that the venue of the action is improper; and that the action, suit or
proceeding is brought in an inconvenient forum. In addition to any other mode of service of process authorized by law,
Buyer consents to service of process by registered or certified mail.
13. COMPLIANCE WITH LAWS. Buyer represents and warrants, in connection with the transactions contemplated by this
Agreement, and any other agreement contemplated by or entered into pursuant to this Agreement, that Buyer will comply
with all governmental laws, regulations and orders that may be applicable to Buyer, including without limitation all laws and
regulations regarding export controls, economic sanctions and trade embargoes, anti-boycott restrictions, anti-money
laundering laws and anti-corruption laws, including but not limited to the U.S. Foreign Corrupt Practices Act (as amended)
and the United Kingdom Bribery laws (collectively, the Applicable International Trade and Anti- Corruption Laws). Buyer
will comply with all applicable Equal Opportunity requirements including those set forth in Executive Order 11246 and
the Vietnam Era Veterans Readjustment Assistance Act of 1974, and regulations promulgated thereunder, the full version
of which is found on Attachment A to this Agreement and incorporated herein by this reference. Buyer acknowledges
and confirms that it and its officers, directors, employees, agents, contractors, designees and/or any other party acting on
its behalf (collectively Related Parties) are familiar with the provisions of the Applicable International Trade and AntiCorruption Laws. Buyer agrees to indemnify, defend and hold harmless Seller and its employees from and against any and
all claims, demands, costs, penalties and fines arising in connection with any alleged breach by Buyer or any of its Related
Parties of this paragraph. Seller may terminate this Agreement in its entirety, without liability to Buyer, if Seller believes
in good faith that Buyer or any of its Related Parties has violated or intends to violate this paragraph.

6/17/2013

McWane, Inc. Terms and Conditions of Sale


14.
ARBITRATION; DISPUTE RESOLUTION; PRESERVATION OF REMEDIES.
All disputes, claims or
controversies (individually or collectively, a Dispute) between Seller and Buyer arising out of or relating to the transactions
contemplated by this Agreement, including without limitation any claim based on or arising from an alleged tort, shall be
resolved by binding arbitration in accordance with Title 9 of the U.S. Code and the Commercial Arbitration Rules of the
American Arbitration Association (the AAA).
The Dispute will be arbitrated in Birmingham, Alabama, U.S.A. Defenses
based on statutes of limitation and similar doctrines will be applicable in any such proceeding, and the commencement of
an arbitration proceeding under this Agreement will be deemed the commencement of an action for such purposes.
The parties will select arbitrators in accordance with the Commercial Arbitration Rules of the AAA.
The AAA will
designate a panel of ten (10) potential arbitrators knowledgeable in the subject matter of the Dispute. Seller and
Buyer each shall designate, within thirty (30) days of the receipt of the list of potential arbitrators, one of the potential
arbitrators to serve, and the two arbitrators so designated shall select a third arbitrator from the eight remaining
candidates. Notwithstanding the foregoing, Seller reserves the right to resolve or bring any Dispute in a court of competent
jurisdiction in accordance with paragraph 12 of these Terms and Conditions.
15. WAIVER. No waiver of any provision, right or remedy contained in this Agreement, including the terms of this
Paragraph 15, is binding on, or effective against, Seller unless expressly set forth in writing and signed by Sellers
authorized representative.
Buyer expressly agrees that no right or remedy provided for in this Agreement can be
waived through course of dealing, course of performance or trade usage. Buyer expressly agrees and acknowledges that
reliance on any waiver without Sellers written consent is unreasonable. Waiver by Seller of any breach will be limited to
the specific breach so waived and will not be construed as a waiver of any subsequent breach. Sellers approval
or consent to any action proposed by Buyer will not be considered an agreement to the propriety, fitness or usefulness of
the proposed action, and will not affect Buyers obligation to strictly comply with this Agreement and all related orders.
16. ASSIGNMENT. Buyer may not assign this Agreement or any rights or obligations hereunder without Sellers
prior written consent. Any attempted assignment in contravention of this paragraph is void. This Agreement, and the
Terms and Conditions contained herein, are enforceable, however, against Buyers successors and permitted assigns.
17. TAXES. Sellers prices do not include sales, use, excise or other similar taxes. Consequently, in addition to the
price specified herein, Buyer will pay the amount of any present or future such tax, unless Buyer, at the time of sale,
provides Seller with all tax-exemption certificates required by taxing authorities.
18. CUMULATIVE NATURE OF REMEDIES. Sellers remedies in this Agreement are cumulative and in addition to any
other remedies available to Seller, whether at law, equity or otherwise.
19. SEVERABILITY. If any provision or part of a provision contained in this Agreement is held by a court of competent
jurisdiction to be contrary to law or public policy, the remaining provisions of the Agreement will remain in full force and
effect.
20.

CONSTRUCTION. No provision of this Agreement may be construed against the Seller as the drafting party.

6/17/2013

Other TYLER UNION Products Include


Ductile and PVC Restraint Systems
Ductile Iron C153 Fittings in MJ and Union-Tite
Ductile Iron C110 Fittings in MJ and Flanged
Ductile Iron Compact Flanged Fittings
Swivel MJ Fittings For Hydrants
Cast Iron Service & Valve Boxes

www.tylerunion.com
SEARCH INVENTORY for all fittings, accessories,
valve boxes, companion flanges and other products
in stock, 24 hours a day, 7 days a week.

SEE ENTIRE TYLER UNION CATALOG


View, print and download drawings and specifications.

FIND THE COMPLETE LIST PRICE SHEET


page-by-page. Use the index to go to the product group
Distributed By

You might also like