You are on page 1of 1

mnw0340-810.

dgn

6/5/2012

SIDE MOUNTED ALUMINUM


GUARD SEE DETAIL ?????
METAL COPING FLASHING
10M GALVANIZED ANCHORS
@ 400mm OC

CONTINUOUS 15 mm THICK
WOOD SHIM

VARIES
MEMBRANE FLASHING CARRIED
UP & OVER 19mm EXTERIOR GRADE

WOOD COPING TRUSS

PLYWOOD & FASTENED TO FRONT


FACE OF WOOD BLOCKING

ENSURE COMPLETE SEAL


CONTINUOUS METAL

AT PENETRATION

FLASHING CLIP
19mm EXTERIOR GRADE PLYWOOD
ON 38 x 89mm WOOD STRAPPING
@ 400 mm oc

PRECAST CONCRETE
PANEL CONNECTION

40mm RIGID INSULATION FILL

PACK WITH INSULATION


600

METAL COUNTERFLASHING
ROOFING ASSEMBLY

CONTINUOUS
38 X 38 mm

38 X 89 mm
@ 400 mm OC

ISOMETRIC OF WOOD
COPING TRUSS

PRECAST CONCRETE PARAPET DETAIL WITH BACKUP


NTS
' CH2M HILL
NOTE TO DESIGNER:

THIS DETAIL MAY BE PLOTTED IN AN 8 1/2"x11" FORMAT.


PARAPET HEIGHT NEEDS TO BE MINIMUM 600mm

0340-810
18-DEC-09
Wagner, Wayne/TOR