DESIGN OF ANCHOR BOLT FOR POLE:

No.of bolt = 4
From staad analysis page no: 9 (FACTORED LOAD 13), JOINT: 03
Moment acting of base = 5.894 KNM
Tensile force acting on base = 8.444 KN
Based on moment,
Tensile force acting on base = 5.894/0.2= 29.47/2 = 14.74 KN
Tensile force acting/Bolt = 8.444/4 KN
= 2.11 KN
Total Tensile force acting /bolt = 14.74 + 2.11 = 16.85 KN
Shear force acting/Bolt = (0.0 + 4.603) =4.603/4
= 1.15 KN

For M20, 8.8 Grade anchor,


Tensile Capacity of M20, 8.8 grade bolt = 109.80 KN
109.8 KN > 16.85 KN

Hence Safe

Shear Capacity of M20, 8.8 grade bolt = 91.90 KN


91.90 KN > 1.15 KN

Hence Safe

Combined Tension & Shear Check,


16.85/109.80 + 1.15/91.90 <1.4
0.165 <1.4
DESIGN OF BOND LENGTH:
Bond length Ld = F/ x dx x T bd
Where, Tbd =1.534 N/mm (for plain bar)
Tensile load = 16.85 KN
Ld = 16.85 x1000/x20x1.534 = 175 mm

Hence Safe