Lumen Method Summary

Project
Title
Number
Company
Designer

Room
Length [ X ]
Width [ Y ]
Height [ Z ]

8
12
5

RCR

m
m
m

4.42

Ceiling
Walls
Floor
Workplane Height

80
50
20

%
%
%

0.76

Luminaire
Mounting Height
Catalog Number
Manufacturer
IES File Name

2AV G 2 32 MDR
Lithonia Lighting, Lithonia Fluorescent
LTL6960.IES

Lamp Description
Number of Lamps
Lamp Lumens
Light Loss Factor

F32T8/TL841 RATED 2900 LUMENS


2
2900
0.74

Coefficient of Utilization

0.45

Output
Illuminance
Number of Luminaires
Number of Columns [ X ]
Number of Rows
[Y]

302
15

lux

2.44

3
5

Column Spacing
Row Spacing

[X]
[Y]

2.44
2.44

m
m

Column Start
Row Start

[X]
[Y]

1.26
1.12

m
m

1.12

Y
1.26

Power Density

9.53

2.44

Watts/sq. m
X

Note: Calculations are based on procedures established by the Illuminating Engineering Society of North America, or standard industry practice. Visual 2.0
computes output performance based on input data as provided by, and which is the sole responsibility of, the user. The Lithonia Lighting Group cannot be
held responsible for the variations in actual situations which can effect calculated output.