Design Data Sheet

CLIENT NAME
PROJECT NAME

HP P.W.D. B &R NALAGARH DISTT. -SOLAN


BRIDGE OVER SIRSA NADI ON BADDI SITALPUR ROAD
AT RD 1/338 AND KHERA NANOWAL ROAD AT RD
2/700.
2 LANE OF IRC CLASS A LOADING

TYPE OF STRUCTURE
BEARING TYPE
VERTICAL LOAD/BRG.

HORIZONTAL LOAD/
BRG.
LONGITUDINAL
MOVEMENT
TRANSVER
SE
MOVEMEN
T
ROTATION (RADIANS)
PEDESTAL SIZE
Grade Of Concrete

Max. Vertical
Reaction (t)
Min. Vertical
Reaction (t)
Longitudinal (t)
Transverse (t)
+ (MM)
-(MM)
+ (MM)
-(MM)

PB
--

NORMAL
GB
--

GB3
370

--

--

25
------

0.01
Substructure
Superstructure

PB
--

SIESMIC
GB
--

GB3
400

290

--

--

200

--

--

215

--

--

-42
22
---

-42
22
10
10

110

110

--

0.01
0.01
800mm X800mm X300 mm( MinHt.)
M:35
M:45

Designed As Per IRC : 83 ( Part -III) and latest MOST specifications.


Remarks : PB Taking horizontal load only fixed in both direction
GB Taking horizontal load only Allowing movement in L-L only.
GB3 - Allowing movement in all directions.