4.4 General Device Data Power consumption = quiescent = energized Bridging time for failure/short-circuit of the power supply approx. 5 W approx. 7 W 250 ms at Uy = 48 V and Uype 2 110 V 220 ms at Uy = 24 V and Uype = 60 V Alternating Voltage Voltage supply via integrated AC/DC converter Nominal power supply alternating voltage Un, 115/230 VAC Permissible volage ranges, B2ie 265 VAT Power consumption = quiescent approx. 6.5 VA = energized approx. 8.5 VA, Bridging time for failure/short-circuit of the power supply 250ms 4.1.3. Binary Inputs and Outputs Binary Inputs Number Nominal voltage Switching thresholds = for nominal voltages 24/48 VDC 60/110/125 VDC ~ for nominal voltages 110/125 220/250 VDC Current consumption, energized Maximum permissible voltage Input interference suppression 3. (allocatable) 24 VDC to 250 VDC in 2 ranges, bipolar adjustable with jumpers, Upicup 2 19 VDC Usropotr 14 VDC. Upiciup 2 88 VDC Usopotr © 68 VDC. approx. 1.8 mA independent of the control voltage 300 voc 220 nF coupling capacitance at 220 V with recovery time >60 ms Binary Outputs 7UT612 Manual c53000-G1176-c14e-4 Signalling/ command relays (see also General Diagrams in Section A.2 of Appendix A) Number: Switching capability MAKE BREAK Alarm relay Switching capability MAKE BREAK Switching voltage 4, each with 1 NO contact (voltfree) (allocatable) 1000 WiVA 30VA 40 W ohmic 25 W for LIR < 50 ms 1, with 1 NO or NC contact (reconnectable) 1000 WIVA, 30VA 40 W ohmic 25 W for LIR < 50 ms 250V 249 4 Technical Data Permissible current per contact Permissible total current on common paths 5 A continuous 30A for 0.5 s 5 A continuous 30A for 0.5 s 4.1.4 Communications Interfaces Operation Interface — Connection Operation Transmission speed Maximum transmission distance front panel, non-isolated, RS 232 Spin DSUB socket for connecting a personal computer with DIGSI° 4 min. 4800 Baud; max. 115200 Baud factory setting: 38400 Baud; parity: 8E1 15 m(60 ft) Service/Modem __ RS232/RS485/Optical Interface ace. ordered version (optional) RS232 Connection for lush mounted case for surface mounted case Test voltage Transmission speed Maximum transmission distance RS485 — Connection for lush mounted case for surface mounted case ~ Test voltage — Transmission speed ~ Maximum transmission distance ~ Connector Type for flush mounted case for surface mounted case 250 isolated interface for data transfer for operation with DIGSI® 4 or connection of a thermobox rear panel, mounting location °C" S-pin DSUB socket at the inclined housing on the case bottom shielded data cable 500 V; 50 Hz. min. 4800 Baud; max. 115200 Baud factory setting: 38400 Baud 15 m(60f) rear panel, mounting location S-pin DSUB socket at the inclined housing on the case bottom shielded data cable 500 V; 50 Hz. min. 4800 Baud; max. 115200 Baud factory setting: 38400 Baud 1000 m (3300 ft) ‘sT-connector rear panel, mounting location “C” at the inclined housing on the case bottom TUTG12 Manual ‘es2000-61176-C148-1 4.4 General Device Data Optical wavelength Laser class 1 ace, EN 60825-1/ ~2 Permissible optical signal attenuation Maximum transmission distance Character idle state 2.= 820 nm Using glass fibre 60/125 um or using glass fibre 62.5/125 um max. 8 dB using glass fibre 62.5/125 ym 1.5 km (1 mile) selectable; factory setting: “Light off" ‘System (SCADA) Interface (optional) 7UT612 Manual c53000-G1176-c14e-4 RS232/RS485/Optical Profibus RS485/Profibus Optical ace. to ordered version RS232 = Connection for lush mounted case for surface mounted case ~ Test voltage ~ Transmission speed — Maximum transmission distance RS485 Connection for flush mounted case for surface mounted case Test voltage Transmission speed Maximum transmission distance Optical fibre Connector Type for flush mounted case for surface mounted case Optical wavelength Laser class 1 ace, EN 60825-1/ ~2 Permissible optical signal attenuation Maximum transmission distance Character idle state Profibus RS485 (FMS and DP) = Connectionfor flush mounted case for surface mounted case ~ Test voltage isolated interface for data transfer toa master terminal rear panel, mounting location “B" -pin DSUB socket at the inclined housing on the case bottom 500 V; 50 Hz min, 4800 Bd, max. 38400 Bd factory setting: 19200 Bd 15m (0) rear panel, mounting location “B" -pin DSUB socket at the inclined housing on the case bottom 500 V, 50 Hz min, 4800 Bd, max. 38400 Bd factory setting: 19200 Bd 1000 m (3300 ft) sT-connector rear panel, mounting location “B" at the inclined housing on the case bottom 2.= 820 nm Using glass fibre 60/125 um or using glass fibre 62.5/125 um max. 8 dB using glass fibre 62.5/125 ym 1.5 km (1 mile) selectable; factory setting: “Light off" rear panel, mounting location “B” pin DSUB socket at the inclined housing on the case bottom 500 V; 50 Hz 251 4 Technical Data 252 — Transmission speed — Maximum transmission distance Profibus Optical (FMS and DP) Connector Type ~ Connection for flush mounted case for surface mounted case ~ Transmission speed recommended: — Optical wavelength ~ Laser class 1 acc. EN 60825-1/-2 ~ Permissible optical signal attenuation — Maximum transmission distance DNP3.0 RS485 Connectionfor sh mounted case for surface mounted case Test voltage Transmission speed Maximum transmission distance DNP3.0 Optical Connector Type Connection for flush mounted case for surface mounted case Transmission speed Optical wavelength Laser class 1 acc. EN 60825~1/-2 Permissible optical signal attenuation Maximum transmission distance MODBUS RS485 — Connection for flush mounted case for surface mounted case Test voltage up to 1.5 MBd 1000 m (3300 ft) at <93.75 kBd 500m (1640ft) at < 187.5 kBd 200m (660ft) at < 1.5 MBd ST-plug FMS: single ring or twin ring depending on ordered version DP: twin ring only rear panel, mounting location at the inclined housing on the case bottom to 1.5 MBd > 500 kBd 2.= 820 nm Using glass fbre 50/125 um or using glass fibre 62.5/125 um max. 8 dB using glass fibre 62.5/125 ym 41.5 km (1 mile) rear panel, mounting location S-pin DSUB socket at the inclined housing on the case bottom 500 V; 50 Hz. up to 19200 Bd 1000 m (3300 ft) ‘ST-plug transmitterireceiver rear panel, mounting location at the inclined housing on the case bottom up to 19200 Bd 2.= 820 nm Using glass fbre 50/125 jim or using glass fibre 62.5/125 jm max. 8 dB using glass fibre 62.5/125 um 1.5 km (1 mile) rear panel, mounting location S-pin DSUB socket at the inclined housing on the case bottom 500 V; 50 Hz. TUTG12 Manual ‘es2000-61176-C148-1 4.4 General Device Data ~ Transmission speed — Maximum transmission distance MODBUS LWL = Connector Type = Connection for lush mounted case for surface mounted case ~ Transmission speed — Optical wavelength ~ Laser class 1 acc. EN 60825~1/ -2 ~ Permissible optical signal attenuation — Maximum transmission distance up to 19200 Ba 1000 m (3300 ft) ST-plug transmitterireceiver rear panel, mounting location “B" at the inclined housing on the case bottom up to 19200 Ba 2.= 820 nm Using glass fibre 60/125 jim or using glass fibre 62.5/125 um max. 8 dB using glass fibre 62,5/125 wm 1.5km (1 mile) Time ‘Synchronization = Signal type = Connection for lush mounted case for surface mounted case — Nominal signal voltages ~ Signal level and burden: Nominal signal input voltage DCF77IIRIG B-Signal rear panel, mounting location “A’ 9-pin DSUB socket at the terminal on the case bottom optional 5 V, 12 V or 24 V av T2V AV Uirign | 50V T8V aT Titow | TOV AU igy = O25MA | 14 Vat igy =O25MA | TOV AU oy = 025MA Traign [45 mA to 8.4 mA FS mAt SSA TSmAT 8.7 mA R | s0natU=4V Tex NaAU=B7V | SaOaalU,= TV 640 QatU=6V 17002 atU,=15.8V | 3560 0 at U,= 31 V 4.1.5 Electrical Tests Specifications Standards: TEC 60255 (Product standards) ANSI/IEEE C37.90.0; C37.90.0.1 €37.90.0.2 DIN 57435 Part 303 See also standards for individual tests Insulation Tests 7UT612 Manual c53000-G1176-c14e-4 Standards: — High voltage test (routine test) all circuits except power supply, binary inputs, and ‘communication/time syne. interfaces IEC 60255-5 and 60870-2-1 2.5 KV (rms); 50 Hz 253 4 Technical Data — High voltage test (routine test) only power supply and binary inputs ~ High Voltage Test (routine test) only isolated communication ime sync. interfaces — Impulse voltage test (type test) all circuits except communication ime sync. interfaces, class Ill 3.5 kVDC, 500 V (rms); 50 Hz 5 KV (peak); 1.2/50 ps; 0.5 Ws; 3 positive and 3 negative impulses in intervals of 5 s EMC Tests; Interference Immunity (Type Tests) 254 Standards: ~ High frequency test IEC 60255-22-1, class IIL and VDE 0436 part 303, class III ~ Electrostatic discharge IEC 60255-22-2 class IV and IEC 61000-4-2, class IV IEC 60255-6 and ~22 (Product standards) EN 50082-2 (Generic standard) DIN 57435 Part 303 2.5 KV (Peak); 1 MHz; «= 15 ps: 400 surges per s; test duration 2 s R,= 2000 8 KV contact discharge; 15 kV air discharge, both polarities; 150 pF; Rj = 330.0 Irradiation with HF field, non-modulated10 Vim; 27 MHz to 500 MHz IEC 60255-22-3 (report) class Il Irradiation with HF field, amplitude modulated; IEC 61000-4-3, class Ill Irradiation with HF fel, pulse modulated IEC 61000-4-3/ENV 50204, class III — Fast transient disturbance/burst, IEC 60255-22-4 and IEC 61000-4-4, class IV — High energy surge voltages (SURGE), IEC 61000-4-5 installation class 3 power supply analogue inputs, binary inputs and outputs — Line conducted HF, amplitude modulated; IEC 61000-4--6, class III — Power system frequency magnetic field; IEC 61000-4-8, class IV; IEC 60255-6 ~ Oscillatory surge withstand capability ANSIIEEE C37.90.1 — Fast transient surge withstand cap- ability, ANSVIEEE C37.90.1 10 Vim; 80 MHz to 1000 MHz; 80 % AM; 1 kHz 10 Vim; 900 MHz; repetition frequency 200 Hz; duty cycle of 50 % 4 kV; 5/50 ns; 5 kHz; burst length = 15 ms; repetition rate 300 ms; both polarities; R, = 50Q; test duration 1 min impulse: 1.2/50 us common mode: 2 kV; 12.0; 9 uF diff. mode: kV; 20; 18 pF ‘common mode: 2 kV; 42 0; 0.5 UF diff. mode: kV; 42 0; 0.5 UF 10 V; 150 kHz to 80 MHz; 80 % AM; 1 kHz 30 Alm continuous; 300 Alm for 3 s; 50 Hz 0.5 mT; 50 Hz 2.5 to 3 KV (peak value); 1 to 1.5 MHz decaying wave; 50 surges per s; duration 2 s; R= 150.0 to 200.0 4 KV to 5 KV; 10/150 ns; 50 surges per s; both polatities; duration 2 s; R= 800 ~ Radiated electromagnetic interference 36 Vim; 25 MHz to 1000 MHz ANSI/IEEE Std C37.90.2 amplitude and pulse modulated TUTG12 Manual ‘es2000-61176-C148-1 4.4 General Device Data = Damped oscillations IEC 60604, IEC 61000-4~12 2.5 KV (peak value), polarity alternating 100 kHz, 1 MHz, 10 MHz and 50 MHz; R,= 2000 Emston ne ~ Sues Tests) IEC-CISPR 22 EN 50081—" (Generic standard) 10 kHz to 30 MHz limit class B 30 MHz to 1000 MHz limit class 8 4.1.6 Mechanical Stress Tests Viraion and Sands TEC BOTT and EC BOTS Sheek Dung Vaton sinusoita TEC 02S 21-1, cass2 TDHete 60H 0075 mm amplitude tec e088 25 Borete a0 19 accacraton teuency swoop rte octavelnn 20 cycles n 3 orognal ance ~ shock halsine shaped 120 0255-21-2, cass 1 aczaeraion Sg, craton 11 ms tec so0ee-2-27 S socks in each decton of 3 omegorel ates ~ Seismic vibration sinusoidal TEC 80286 2173, cass THeeSHe: <3. mmampltude IEC 60068-3-3 (horizontal axis) Peeters =1.8mmampltude (vertical axis) Seto s8ite 1g acceleration ihorzontal x) Bret Ssh” 059 accelraton (vera ans) Feauoncy Sweep rate otvetnn ‘oem ottepor aces raion nd Sandaas TEC 60286-21 and TEC 60088 ShockDurng ——— vpraon sinsoia por IEC 60255-21-1, class 2 5 Hz to 8 Hz: 5 mm amplitude tec e068 28 Bnet 120k: 2g accderaion Preauoncy sweep rt octave Docyaesin 3 orhogona! anes ~ shock halsine shaped 120 0255-21-2, cass 1 dczseraon 1 9; draton 1 ms tec so0ee-2-27 Socks in each drecton of 7UT612 Manual c53000-G1176-c14e-4 3 orthogonal axes 255 4 Technical Data ~ Continuous shock IEC 60255-21-2, class 1 acceleration 10 g; duration 16 ms; IEC 60068-2-29 1000 shocks in each direction of 3 orthogonal axes 4.1.7 Climatic Stress Tests Ambient Standards: TEC 60255-6 ‘Temperatures — recommended operating temperature -5 °C to +55 °C (+23 °F to +131 °F) ~ limiting temporary transient) -20°C to +70°C Villy of spay operating temperature (4°Ft0158°F) Sie AS0-r in quiescent stata, 2. no pickup and no incications limiting temperature during storage -25 °C to +55 °C (-13 °F to 131 °F) limiting temperature during transport -25 °C to +70 °C (-13 °F to 158 *F) Storage and transport of the device with factory packaging! Humidity Permissible humicity mean value p. year <75 % relative humidity on 56 days per year up to 93 % relative humidity; condensation not permissible! All devices shall be installed such that they are not exposed to direct sunlight, nor subject to large fluctuations in temperature that may cause condensation to occur. 4.1.8 Service Conditions The device is designed for use in an industrial environment or an electrical utility environment, for installation in standard relay rooms and compartments so that proper installation and electromagnetic compatibility (EMC) is ensured. In addition, the following are recommended: ‘ All contactors and relays that operate in the same cubicle, cabinet, or relay panel as the numerical protective device should, as a rule, be equipped with suitable surge suppression components. ‘+ For substations with operating voltages of 100 kV and above, all external cables should be shielded with a conductive shield grounded at both ends. The shield must be capable of carrying the fault currents that could occur. For substations with lower operating voltages, no special measures are normally required * Do not withdraw or insert individual modules or boards while the protective device is energized. When handling the modules or the boards outside of the case, standards for components sensitive to electrostatic discharge (ESD) must be observed. The modules, boards, and device are not endangered when the device is completely assembled. 256 TUTG12 Manual ‘es2000-61176-C148-1 4.4 General Device Data 4.1.9 Construction Housing 7xP20 Dimensions see drawings, Section 4.15 Weight (mass), approx. = in flush mounted case, size V/p 5.1kg (11% Ib) ~ in surface mounted case, size "lz 9.6 kg (21g Ib) Degree of protection ace. IEC 60529 = for the device in surface mounted case IPs in flush mounted case front IPs rear IP 50 = for human safety IP 2x with closed protection cover 7UT612 Manual 257 c53000-G1176-c14e-4 4 Technical Data 4.2 Differential Protection 4241 General Pickup Values Differential current IpyFr>lIoyy 0.05102.00 (steps 0.01) High-current stage Ipyre>>IInowy 0.510.350 —_—_(steps 0.1) or = (stage ineffective) Pickup on switch-on (actor of lors) 1.01020 (steps 0.1) ‘Add-on stabilization on external faut (inesi> Set value) Iggzonlosy 2.000 15.00 (steps 0.01) action time 210250 cycles (steps 1 cycle) or = (effective until dropoft) ‘Trip characteristic see Figure 4-1 Tolerances (at preset parameters) ~ loire> stage and characteristic «5 % of set value = Ipipe>> stage 5 % of set value Time Delays: Delay ofinyr> stage Tior> —0.008t060.008 (sleps0.01s) or = (no trip) Delay of Ine? Stage T.oiers» -—0.00s to 60.008 (steps 0.01 s) or = (no trip) Time tolerance 1 % of set value or 10 ms The set times are pure delay times Fault Characteristic Is + ta laa Stabilizing curent= [1] + [ll inen) Nominal current of prot. abjact 1 s-DnFe> 10 11 12 13 14 18 16 17 lam BASE POINT 1 BASE POINT 2 1-00 0N STAB non Figure 4-1 Tripping characteristic of the differential protection 258 TUTG12 Manual ‘es2000-61176-C148-1

You might also like