You are on page 1of 2

ZXG10 iBSC-BSC-SYS/GU-8K clock source lost.

Product

ZXG10 iBSC/GUBSC/GU Wireless


System/GU

Network
IOMCRV6.20.614HManagement
OMCBV4.00.200M-0718.zip
Version
Equipment
iBSCV6.20.614D.zip
Software Version
Board Software
Version

Equipment
Hardware Version
Board Hardware
Version
Incident Error
Page Views
10
Code
Author
WangShiHao
Knowledge No.
WHD20120614394409
Incident Description (Incident Phenomena)
BSC 8K clock source lost ,and the clock board phase-lock loop work mode abnormal .
Networking Environment
Problem Cause Analysis
1.CLKG board fauty .2.Clock extracting cable issue .3.Transmission clock issue.
Solution

1Check the clock extracting cable on both SDTB&CLKG sides,it is connected firmly and not
break down!
2Change the clock extracting cable and check again ,the 8K clock not get normal

3Check the CLKG hardware version ,make sure the extracting cable physic connect is
correct
.

4. Handover the slave CLKG to master and check again ,the 8K clock not get normal
.
5. Check CLKG board printing ,it is showing as follows ,it is alreday exceed limits ,the clock
frequency should between -4.6ppm to +4.6ppm ,that's why our BSC can not trace the 8K
clock .
I1 : Prioity = 0 ; State = ActAlm ; Freq Offset = -487.679993 ppm
I2 : Prioity = 0 ; State = ActAlm ; Freq Offset = -487.679993 ppm
I3 : Prioity = 0 ; State = ActAlm ; Freq Offset = -487.679993 ppm
I4 : Prioity = 0 ; State = ActAlm ; Freq Offset = -487.679993 ppm
I5 : Prioity = 0 ; State = ActAlm ; Freq Offset = -487.679993 ppm

I6 : Prioity = 0 ; State = ActAlm ; Freq Offset = -487.679993 ppm


I7 : Prioity = 0 ; State = ActAlm ; Freq Offset = -487.679993 ppm
I8 : Prioity = 0 ; State = ActAlm ; Freq Offset = -487.679993 ppm
I9 : Prioity = 2 ; State = SoftAlm ; Freq Offset = -7.620000 ppm
I10 : Prioity = 0 ; State = ActAlm ; Freq Offset = -487.679993 ppm
I11 : Prioity = 0 ; State = NoAlm ; Freq Offset = -3.810000 ppm
I12 : Prioity = 0 ; State = ActAlm ; Freq Offset = -487.679993 ppm
I13 : Prioity = 0 ; State = ActAlm ; Freq Offset = -487.679993 ppm
I14 : Prioity = 0 ; State = NoAlm ; Freq Offset = -3.810000 ppm
6. Check the network topology and finding that BSC get the 8K clock from MUX equipment ,ask
transmission side check the clock source quality of MUX,it is also not normal.
7. After MUX equipment change the Clock board ,the clock of BSC and MUX all get normal .