5.1.1 Required tracer size shall be determined by piping heat loss and tracer steam pressure found in the Heat Loss Chart (Attachment 1.) 5.1.2 Minimum tracer size shall be 3/8 of an inch OD tubing; maximum size shall be 1 inch OD tubing. For economy, where Heat Loss Chart indicates the requirements for multiple tracers, a single tracer with heat transfer cement shall be considered. 5.1.3 When using heat transfer cement, tracers of 3/8 of an inch and 1/2 of an inch OD tubing are recommended. If more tracer area is required, multiple tracers of 3/8 of an inch and 1/2 of an inch shall be used. 5.1.4 Maximum tracer length shall be based on tracer size and steam pressure as follows: a. Steam pressure 1 Bar through 1.7 Bar (i) 60m for 3/8 of an inch and 1/2 of an inch tracers (ii) 100m for 3/4 of an inch and 1 inch tracers b. Steam pressure 3.5 Bar through 13.8 Bar (i) 60m for 3/8 of an inch and 1/2 of an inch tracers (ii) 120m for 3/4 of an inch and 1 inch tracers c. Tracer lengths for tracing with heat transfer cement shall be based on recommendation of manufacturer. 5.1.5 For stainless steel lines, the tracer material shall be low carbon steel. Stainless steel instrument leads shall be traced with copper tubing. 5.1.6 Each tracer shall have its own trap. Tracer traps shall discharge to sewer. If condensate must be collected, minimum usable pressure is 1.7 Bar.
5.1.7 Compression type fittings shall be installed outside of the insulation
OD. 5.1.8 Socket type fittings may be installed inside of the insulation.